Jobcard Summary (Tkp-A Structure)

Embed Size (px)

DESCRIPTION

jobcards

Citation preview

TKP-A (STRUCTURAL)TRADESNOJOBCARD NOPLATFORMLOCATIONDRAWINGSPHASECATSCOPE DESCRIPTION / JOBCARDS TITLERGRSFW BPMWSFSWLPFPWLIFITELENDT WHCCHBTVRTOTAL MHRS15-851-X-001-ATKP-ASDPre-SDSCAFFErect scaffolds for gangway installation52.1668.32120.4825-851-S-201-ASDPre-SDINSTALLInstallation of Gangway145.74145.7437-851-X-701-ATKP-ASDPre-SDDESCAFFDismantle scaffolds after gangway installation25.3144.1669.474565-XXX-S-806-ATKP-ACDPre-SDGENWashdown at drip pans below CD prior to hotwork/demolition21.0021.007895-851-X-002-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5406-1Pre-SDSCAFFErect scaffolds for deck strenthening at Cellar Deck. 55.1884.36139.54105-851-Y-101-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5406-1Pre-SDHBTSet-up safety habitat for deck strengthening at Cellar Deck.25.5050.0040.00115.50115-851-S-202-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5406-1Pre-SDINSTALLInstallation of deck strengthening at Cellar Deck. 27.4354.242.0022.3648.56154.59125-851-S-401-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5406-1Pre-SDNDTNDT at weldments of strengthened members (Cellar Deck).2.8014.0016.80137-851-Y-601-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5406-1Pre-SDDHBTDismantle safety habitat after deck strengthening at Cellar Deck.23.7535.0020.0078.75145-851-B-501-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5406-1Post-SDTPTouch-up painting for strengthened members at Cellar Deck.2.508.0010.50157-851-X-702-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5406-1Post-SDDESCAFFDismantle scaffolds after deck strenthening at Cellar Deck.27.0347.1874.211617185-851-X-003-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-S-5002(R )05-TKP-A-S-5000(R )Pre-SDSCAFFErect scaffolds for removal of existing beams, grating panels and handrails at leg B1 (CD).45.5275.03120.55195-851-Y-102-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-S-5002(R )05-TKP-A-S-5000(R )Pre-SDHBTSet-up safety habitat for demolition of existing beams, grating panels & handrails at leg B1 (CD).24.1038.0024.0086.10207-851-S-301-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-S-5002(R )05-TKP-A-S-5000(R )Pre-SDREMOVERemoval of existing beams, grating panels & handrails at leg B1 (CD).66.8846.001.0041.10154.98217-851-Y-602-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-S-5002(R )05-TKP-A-S-5000(R )Pre-SDDHBTDismantle safety habitat after demolition of existing beams, grating panels & handrails at leg B1 (CD).23.0529.0012.0064.05227-851-X-703-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-S-5002(R )05-TKP-A-S-5000(R )Pre-SDDESCAFFDismantle scaffold after removal of existing beams, grating panels and handrails at leg B1 (CD).32.5147.5280.0323245-851-X-004-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-S-5002(R )Pre-SDSCAFFErect scaffolds for removal of existing handrails at leg B2 (CD).43.8371.65115.48255-851-Y-103-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-S-5002(R )Pre-SDHBTSet-up safety habitat for demolition of existing handrails at leg B2 (CD)24.1038.0024.0086.10267-851-S-302-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-S-5002(R )Pre-SDREMOVERemoval of existing handrails at leg B2 (CD)19.618.001.0011.4640.07277-851-Y-603-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-S-5002(R )Pre-SDDHBTDismantle safety habitat after demolition of existing handrails at leg B2 (CD)23.0529.0012.0064.05287-851-X-704-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-S-5002(R )Pre-SDDESCAFFDismantle scaffold after removal of existing handrails at leg B2 (CD).31.5445.8377.3729305-851-X-005-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDSCAFFErect scaffolds for installation of Panel 1 (CD - East Side)89.62163.25252.87315-851-S-801-ATKP-ACD05-TKP-A-ST-5411-1/2Pre-SDL&RLift-up Panel 1 from workbarge onto its designated position90.6090.60325-851-Y-104-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDHBTSet-up safety habitat for installation of Panel 1 at CD29.2068.0096.00193.20335-851-S-203-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDINSTALLInstall Panel 1 at CD88.6033.362.0020.5727.24171.77345-851-S-402-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDNDTNDT at weldments of Panel 1 2.508.0010.50357-851-Y-604-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDDHBTDismantle safety habitat after installation of Panel 1 at CD25.6044.0048.00117.60365-851-X-006-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDSCAFFErect scaffolds for installation of loose beams for panel 1 at CD49.7673.52123.28375-851-Y-105-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDHBTSet-up safety habitat for installation of loose beams for Panel 1 at CD24.1038.0024.0086.10385-851-S-204-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDINSTALLInstall loose beams at Panel 1 (CD)23.6121.742.0019.2413.0879.67395-851-S-403-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDNDTNDT at weldments of loose beams (Panel 1)2.8014.0016.80407-851-Y-605-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDDHBTDismantle safety habitat after installation of loose beams for Panel 1 at CD23.0529.0012.0064.05415-851-B-503-CTKP-ACD05-TKP-A-ST-5402-1Post-SDTPTouch-up painting for loose beams for panel 1 at CD2.508.0010.50427-851-X-706-CTKP-ACD05-TKP-A-ST-5402-1Post-SDDESCAFFDismantle scaffolds after installation of loose beams for panel 1 at CD34.9451.7686.70435-851-X-007-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Pre-SDSCAFFErect scaffolds for installation of diagonal brace at Truss Row '2' (Leg B2)39.5653.1092.66445-851-Y-106-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Pre-SDHBTSet-up safety habitat for installation of diagonal brace at Truss Row '2' (leg B2)24.3040.0026.0090.30455-851-S-205-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Pre-SDINSTALLInstall diagonal brace at at Truss Row '2' (leg B2)30.2029.662.0013.4829.40104.74465-851-S-404-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Pre-SDNDTNDT at weldments of diagonal brace at Truss Row '2' (leg B2)2.406.008.40477-851-Y-606-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Pre-SDDHBTDismantle safety habitat after installation of diagonal brace at Truss Row '2' (leg B2)23.1530.0013.0066.15485-851-B-504-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Post-SDTPTouch-up painting for diagonal brace at Truss Row'2' (leg B2)2.304.006.30497-851-X-707-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Post-SDDESCAFFDismantle scaffolds after installation of diagonal brace at Truss Row'2' (leg B2)29.1041.5670.66505-851-B-502-CTKP-ACD05-TKP-A-ST-5402-1Post-SDTPTouch-up painting at Panel 1 2.355.007.35517-851-X-705-CTKP-ACD05-TKP-A-ST-5402-1Post-SDDESCAFFDismantle scaffolds at East side of CD after installation of Panel 158.22101.62159.8452535-851-X-008-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDSCAFFErect scaffolds for installation of Panel 2 (CD - East Side)45.7975.58121.37545-851-S-802-ATKP-ACD05-TKP-A-ST-5411-1/2Pre-SDL&RLift-up Panel 2 from workbarge onto its designated position42.2342.23555-851-Y-107-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDHBTSet-up safety habitat for installation of Panel 2 at CD24.1038.0024.0086.10565-851-S-206-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDINSTALLInstall Panel 2 at CD43.9039.412.0022.2233.66141.19575-851-S-405-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDNDTNDT at weldments of Panel 22.6010.0012.60587-851-Y-607-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDDHBTDismantle safety habitat after installation of Panel 2 at CD23.0529.0012.0064.05595-851-X-009-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDSCAFFErect scaffolds for installation of loose beam for Panel 2 at CD53.6781.34135.01605-851-Y-108-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDHBTSet-up safety habitat for installation of loose beam for Panel 2 at CD25.0046.0034.00105.00615-851-S-207-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDINSTALLInstall loose beams at Panel 2 (CD)47.4460.012.0042.2641.08192.79625-851-S-406-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDNDTNDT at weldments of loose beams (Panel 2)3.8034.0037.80637-851-Y-608-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDDHBTDismantle safety habitat after installation of loose beams for Panel 2 at CD23.5033.0017.0073.50645-851-B-506-CTKP-ACD05-TKP-A-ST-5402-1Post-SDTPTouch-up painting for loose beams for panel 2 at CD3.0018.0021.00657-851-X-709-CTKP-ACD05-TKP-A-ST-5402-1Post-SDDESCAFFDismantle scaffolds after installation of loose beams for Panel 2 at CD37.1755.6792.84665-851-X-010-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Pre-SDSCAFFErect scaffolds for installation of diagonal brace at Truss Row '1' (Leg B1)43.5553.1096.65675-851-Y-109-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Pre-SDHBTSet-up safety habitat for installation of diagonal brace at Truss Row '1' (leg B1)24.5044.0026.0094.50685-851-S-208-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Pre-SDINSTALLInstall diagonal brace at Truss Row '1' (leg B1)30.2029.662.0013.4829.40104.74695-851-S-407-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Pre-SDNDTNDT at weldments of diagonal brace at Truss Row '1' (leg B1)2.406.008.40707-851-Y-609-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Pre-SDDHBTDismantle safety habitat after installation of diagonal brace at Truss Row '1' (leg B1)23.2532.0013.0068.25715-851-B-507-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Post-SDTPTouch-up painting for diagonal brace at Truss Row'1' (leg B1)2.304.006.30727-851-X-710-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5403-1Post-SDDESCAFFDismantle scaffolds after installation of diagonal brace at Truss Row '1' (leg B1)29.1041.5670.66735-851-B-505-CTKP-ACD05-TKP-A-ST-5402-1Post-SDTPTouch-up painting at Panel 2 2.406.008.40747-851-X-708-CTKP-ACD05-TKP-A-ST-5402-1Post-SDDESCAFFDismantle scaffolds at East side of CD after installation of Panel 232.6747.7980.4675765-851-X-011-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDSCAFFErect scaffolds for installation of Panel 3 (CD - East Side)74.21132.41206.62775-851-S-803-ATKP-ACD05-TKP-A-ST-5411-2/2Pre-SDL&RLift-up Panel 3 from workbarge onto its designated position74.9374.93785-851-Y-110-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDHBTSet-up safety habitat for installation of Panel 3 at CD26.2056.0048.00130.20795-851-S-209-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDINSTALLInstall Panel 3 at CD74.2337.852.0021.2532.55167.88805-851-S-408-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDNDTNDT at weldments of Panel 32.6010.0012.60817-851-Y-610-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDDHBTDismantle safety habitat after installation of Panel 3 at CD24.1038.0024.0086.10825-851-X-012-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDSCAFFErect scaffolds for installation of diagonal brace at Truss Row 'B' (Leg B2)37.0648.1285.18835-851-Y-111-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDHBTSet-up safety habitat for installation of diagonal braces section at Truss Row 'B' (leg B2)23.4032.0016.0071.40845-851-S-210-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDINSTALLInstall diagonal braces at Truss Row 'B' (leg B2)28.9229.662.0013.4829.40103.46855-851-S-409-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDNDTNDT at weldments of diagonal braces at Truss Row 'B' (leg B2)2.406.008.40867-851-Y-611-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDDHBTDismantle safety habitat after installation of diagonal braces at Truss Row 'B' (leg B2)22.7026.008.0056.70875-851-B-509-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Post-SDTPTouch-up painting for diagonal brace Truss Row 'B' (leg B2)2.304.006.30887-851-X-712-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Post-SDDESCAFFDismantle scaffolds after installation of diagonal braces at Truss Row 'B' (leg B2)16.6829.0645.74895-851-X-013-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDSCAFFErect scaffolds for installation of diagonal brace Section A (Panel 3)42.7859.57102.35905-851-Y-112-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDHBTSet-up safety habitat for installation of diagonal braces section A (Panel 3)24.4044.0024.0092.40915-851-S-211-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDINSTALLInstall diagonal braces section A (Panel 3)35.0229.662.0013.4829.40109.56925-851-S-410-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDNDTNDT at weldments of diagonal braces section A (Panel 3)2.406.008.40937-851-Y-612-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDDHBTDismantle safety habitat after installation of diagonal braces section A (Panel 3)23.2032.0012.0067.20945-851-B-510-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Post-SDTPTouch-up painting for diagonal brace section A (Panel 3)2.304.006.30957-851-X-713-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Post-SDDESCAFFDismantle scaffolds after installation of diagonal brace section A (Panel 3)30.9544.7875.73965-851-B-508-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Post-SDTPTouch-up painting at Panel 32.406.008.40977-851-X-711-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Post-SDDESCAFFDismantle scaffolds at East side of CD after installation of Panel 348.9176.21125.1298995-851-X-014-CTKP-ACD05-TKP-A-ST-5407-1Post-SDSCAFFErect scaffolds for installation of Pipe coaming17.1126.2243.331005-851-Y-113-CTKP-ACD05-TKP-A-ST-5407-1Post-SDHBTSet-up safety habitat for installation of pipe coaming23.1032.0010.0065.101015-851-S-212-CTKP-ACD05-TKP-A-ST-5407-1Post-SDINSTALLInstall pipe coaming c/w deck plate at CD49.3656.692.0037.9140.87186.831025-851-S-411-ATKP-ACD05-TKP-A-ST-5407-1Post-SDNDTNDT at weldments of pipe coaming & plate3.0018.0021.001037-851-Y-613-CTKP-ACD05-TKP-A-ST-5407-1Post-SDDHBTDismantle safety habitat after installation of pipe coaming22.5526.005.0053.551045-851-B-511-CTKP-ACD05-TKP-A-ST-5407-1Post-SDTPTouch-up painting at pipe coaming & plate2.6010.0012.601057-851-X-714-CTKP-ACD05-TKP-A-ST-5407-1Post-SDDESCAFFDismantle scaffolds for installation of Pipe coaming 13.2823.1136.391061075-851-S-213-CTKP-ACD05-TKP-A-ST-5407-1Post-SDINSTALLInstall gratings at Panel 1, Panel 2 & Panel 3144.5663.202.0053.80101.00364.561085-851-Y-114-CTKP-ACD05-TKP-A-ST-5407-1Post-SDHBTSet-up safety habitat for installation of handrails at Panel 1, 2 & 328.3074.0072.00174.301095-851-S-214-CTKP-ACD05-TKP-A-ST-5407-1Post-SDINSTALLInstall handrails for Panel 1, 2, & 367.4548.902.0061.6024.40204.351105-851-S-412-CTKP-ACD05-TKP-A-ST-5407-1Post-SDNDTNDT at weldments of handrails (Panel 1, 2 & 3)9.20142.00151.201117-851-Y-614-CTKP-ACD05-TKP-A-ST-5407-1Post-SDDHBTDismantle safety habitat after installation of handrails at Panel 1, 2 & 325.1547.0036.00108.151125-851-B-512-CTKP-ACD05-TKP-A-ST-5407-1Post-SDTPTouch-up painting for handrails at Panel 1, 2 & 35.7072.0077.701131141155-851-X-015-ATKP-ACD05-TKP-A-S-5002( R)Pre-SDSCAFFErect scaffolds for removal of existing handrails at leg A2 (CD).18.6229.2447.861165-851-Y-115-ATKP-ACD05-TKP-A-S-5002( R)Pre-SDHBTSet-up safety habitat for demolition of existing handrails at leg A2 (CD)23.1032.0010.0065.101177-851-S-303-ATKP-ACD05-TKP-A-S-5002( R)Pre-SDREMOVEDemolish existing handrails at leg A2 (CD)13.393.001.007.5624.951187-851-Y-615-ATKP-ACD05-TKP-A-S-5002( R)Pre-SDDHBTDismantle safety habitat after demolition of existing handrails at leg A2 (CD)22.5526.005.0053.551197-851-X-714-ATKP-ACD05-TKP-A-S-5002( R)Pre-SDDESCAFFDismantle scaffold for removal of existing handrails at leg A2 (CD).14.1424.6238.761201215-851-X-016-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDSCAFFErect scaffolds for installation of Panel 4 (CD - South Side)69.87123.74193.611225-851-S-804-ATKP-ACD05-TKP-A-ST-5411-2/2Pre-SDL&RLift-up Panel 4 from workbarge onto its designated position70.0470.041235-851-Y-116-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDHBTSet-up safety habitat for installation of Panel 4 at CD26.2056.0048.00130.201245-851-S-215-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDINSTALLInstall Panel 4 at CD68.2131.802.0019.6026.13147.741255-851-S-413-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDNDTNDT at weldments of Panel 4 2.508.0010.501267-851-Y-616-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDDHBTDismantle safety habitat after installation of Panel 4 at CD24.1038.0024.0086.101275-851-X-017-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDSCAFFErect scaffolds for installation of vertical braces section B (Panel 4)20.0432.0852.121285-851-Y-117-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDHBTSet-up safety habitat for installation of vertical braces section B (Panel 4)23.1032.0010.0065.101295-851-S-216-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDINSTALLInstall vertical braces section B (Panel 4)19.0412.012.0011.008.3452.391305-851-S-414-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDNDTNDT at weldments of vertical braces section B (Panel 4)2.406.008.401317-851-Y-617-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDDHBTDismantle safety habitat after installation of vertical braces section B (Panel 4)22.5526.005.0053.551325-851-B-514-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Post-SDTPTouch-up painting at vertical braces Section B (Panel 4)2.304.006.301337-851-X-717-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Post-SDDESCAFFDismantle scaffolds for installation of vertical braces section B (Panel 4)14.9526.0440.991345-851-X-018-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDSCAFFErect scaffolds for installation of vertical braces section C (Panel 4)20.0432.0852.121355-851-Y-118-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDHBTSet-up safety habitat for installation of vertical braces section C (Panel 4)23.1032.0010.0065.101365-851-S-217-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDINSTALLInstall vertical braces section C (Panel 4)19.0412.012.0011.008.3452.391375-851-S-415-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDNDTNDT at weldments of vertical braces section C (Panel 4)2.406.008.401387-851-Y-618-ATKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDDHBTDismantle safety habitat after installation of vertical braces section C (Panel 4)22.5526.005.0053.551395-851-B-515-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Post-SDTPTouch-up painting at vertical braces Section C (Panel 4)2.304.006.301407-851-X-718-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Pre-SDDESCAFFDismantle scaffolds after installation of vertical braces section C (Panel 4)14.9526.0440.991415-851-B-513-CTKP-ACD05-TKP-A-ST-5402-105-TKP-A-ST-5404-1Post-SDTPTouch-up painting at Panel 4 2.355.007.351425-851-X-019-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDSCAFFErect scaffolds for installation of loose beams between Panel 3 and Panel 4 at CD50.0974.18124.271435-851-Y-119-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDHBTSet-up safety habitat for installation of loose beams between Panel 3 and Panel 4 at CD24.1038.0024.0086.101445-851-S-218-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDINSTALLInstall loose beams between Panel 3 and Panel 4 at CD55.1974.212.0048.2854.00233.681455-851-S-416-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDNDTNDT at weldments of loose beams between Panel 3 and Panel 4 at CD3.8034.0037.801465-851-B-516-CCD05-TKP-A-ST-5402-2TPTouch-up painting for loose beams between Panel 3 and Panel 4 at CD3.0018.001477-851-Y-619-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDDHBTDismantle safety habitat after installation of loose beams between Panel 3 and Panel 4 at CD23.0529.0012.0064.051487-851-X-719-CTKP-ACD05-TKP-A-ST-5402-1Post-SDDESCAFFDismantle scaffolds after installation of loose beams between Panel 3 and Panel 4 at CD35.1352.0987.221497-851-X-716-CTKP-ACD05-TKP-A-ST-5402-1Post-SDDESCAFFDismantle scaffolds at South side of CD (after installation of Panel 4)46.9381.87128.801501515-851-X-020-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDSCAFFErect scaffolds for installation of Panel 5 (CD - South Side)36.5857.1593.731525-851-S-805-ATKP-ACD05-TKP-A-ST-5411-2/2Pre-SDL&RLift-up Panel 5 from workbarge onto its designated position36.8436.841535-851-Y-120-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDHBTSet-up safety habitat for installation of Panel 5 at CD23.4032.0016.0071.401545-851-S-219-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDINSTALLInstall Panel 5 at CD33.0922.872.0015.4018.4291.781555-851-S-417-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDNDTNDT at weldments of Panel 5 2.406.008.401567-851-Y-620-ATKP-ACD05-TKP-A-ST-5402-1Pre-SDDHBTDismantle safety habitat after installation of Panel 5 at CD22.7026.008.0056.701575-851-B-517-CTKP-ACD05-TKP-A-ST-5402-1Post-SDTPTouch-up painting at Panel 5 2.304.006.301587-851-X-720-CTKP-ACD05-TKP-A-ST-5402-1Post-SDDESCAFFDismantle scaffolds at South side of CD (after installation of Panel 5) 27.9048.5876.481591605-851-S-220-CTKP-ACD05-TKP-A-ST-5407-1Post-SDINSTALLInstall gratings at Panel 4 & 562.9425.802.0025.2040.50156.441615-851-Y-121-CTKP-ACD05-TKP-A-ST-5407-1Post-SDHBTSet-up safety habitat for installation of handrails at Panel 4 & 525.2050.0034.00109.201625-851-S-221-CCD05-TKP-A-ST-5407-1Post-SDINSTALLInstall handrails for Panel 4 & 537.5522.102.0030.4011.60103.651635-851-S-418-CTKP-ACD05-TKP-A-ST-5407-1Post-SDNDTNDT at weldments of handrails (Panel 4 & 5)7.20102.00109.201647-851-Y-621-CTKP-ACD05-TKP-A-ST-5407-1Post-SDDHBTDismantle safety habitat after installation of handrails at Panel 4 & 523.6035.0017.0075.601655-851-B-518-CTKP-ACD05-TKP-A-ST-5407-1Post-SDTPTouch-up painting for handrails at Panel 4 and Panel 53.7032.0035.701661671685-851-X-021-ATKP-ACD05-TKP-A-ST-5408-1Pre-SDSCAFFErect scaffolds for SDV service platform installation (below CD, leg B2)44.7063.40108.101695-851-Y-122-ATKP-ACD05-TKP-A-ST-5408-1Pre-SDHBTSet-up safety habitat for installation of SDV service platform & associated members24.8044.0032.00100.801705-851-S-222-ACD05-TKP-A-ST-5408-1Pre-SDINSTALLInstall framing of SDV service platform below CD, leg B240.1810.932.008.209.7171.021715-851-S-223-ATKP-ACD05-TKP-A-ST-5408-1Pre-SDINSTALLInstall supporting tubular & braces of SDV service platform below CD, leg B239.4474.782.0043.0062.70221.921725-851-S-224-ATKP-ACD05-TKP-A-ST-5408-1Pre-SDINSTALLInstall vertical ladder of SDV service platform below CD, leg B226.4317.992.0015.8813.1075.401735-851-S-225-CTKP-ACD05-TKP-A-ST-5408-1Pre-SDINSTALLInstall gratings of SDV service platform below CD, leg B222.137.102.0010.9010.2552.381745-851-S-226-CTKP-ACD05-TKP-A-ST-5408-1Pre-SDINSTALLInstall handrails of SDV service platform below CD, leg B226.3213.392.0020.267.4469.411755-851-S-419-ATKP-ACD05-TKP-A-ST-5408-1Pre-SDNDTNDT at weldments of SDV service platform framing2.304.006.301765-851-S-420-ATKP-ACD05-TKP-A-ST-5408-1Pre-SDNDTNDT at weldments of supporting tubular & braces (SDV service platform)3.8034.0037.801775-851-S-421-ATKP-ACD05-TKP-A-ST-5408-1Pre-SDNDTNDT at weldments of vertical ladder (SDV service platform)2.406.008.401785-851-S-422-CTKP-ACD05-TKP-A-ST-5408-1Pre-SDNDTNDT at weldments of handrails (SDV service platform)3.9036.0039.901797-851-Y-622-ATKP-ACD05-TKP-A-ST-5408-1Pre-SDDHBTDismantle safety habitat after installation of SDV service platform & associated members23.4032.0016.0071.401805-851-B-519-CTKP-ACD05-TKP-A-ST-5408-1Post-SDTPTouch-up painting at SDV service platform and associated tubular supports, braces & handrails3.9036.0039.901815-851-B-520-CTKP-ACD05-TKP-A-ST-5408-1Post-SDTPTouch-up painting at vertical ladder of SDV service platform2.304.006.301827-851-X-721-CTKP-ACD05-TKP-A-ST-5408-1Post-SDDESCAFFDismantle scaffolds after SDV service platform installation32.0546.7078.751831841855-851-X-022-ATKP-ACD05-TKP-A-ST-5409-1Pre-SDSCAFFErect scaffolds for drip pan installation52.1378.26130.391865-851-Y-123-ATKP-ACD05-TKP-A-ST-5409-1Pre-SDHBTSet-up safety habitat for installation of drip pan and associated members under Panel 1 & 224.1038.0024.0086.101875-851-S-227-ATKP-ACD05-TKP-A-ST-5409-1Pre-SDINSTALLInstall drip pan and associated members under Panel 1 & 273.9276.412.0047.8560.03260.211885-851-S-423-ATKP-ACD05-TKP-A-ST-5409-1Pre-SDNDTNDT at weldments of drip pan and associated members3.2022.0025.201897-851-Y-623-ATKP-ACD05-TKP-A-ST-5409-1Pre-SDDHBTDismantle safety habitat after installation of drip pan and associated members under Panel 1 & 223.0529.0012.0064.051905-851-B-521-CTKP-ACD05-TKP-A-ST-5409-1Post-SDTPTouch-up painting at drip pan and associated members2.7012.0014.701917-851-X-722-CTKP-ACD05-TKP-A-ST-5409-1Post-SDDESCAFFDismantle scaffolds after drip pan installation36.2954.1390.421921931945-851-X-023-ATKP-ASD05-TKP-A-ST-0319-1Pre-SDSCAFFErect scaffolds for tubular strenthening at SD39.9953.9893.971955-851-Y-124-ATKP-ASD05-TKP-A-ST-0319-1Pre-SDHBTSet-up safety habitat for installation of horizontal tubular strengthening at SD24.5044.0026.0094.501965-851-S-228-ATKP-ASD05-TKP-A-ST-0319-1Pre-SDINSTALLHorizontal tubular strengthening at SD32.9041.002.0028.0832.58136.561975-851-S-424-ATKP-ASD05-TKP-A-ST-0319-1Pre-SDNDT NDT at weldments of strengthened horizontal tubular at SD2.8014.0016.801987-851-Y-624-ATKP-ASD05-TKP-A-ST-0319-1Pre-SDDHBTDismantle safety habitat after installation of horizontal tubular strengthening at SD23.2513.0036.251995-851-B-522-CTKP-ASD05-TKP-A-ST-0319-1Post-SDTPTouch-up painting for strengthened members at SD2.508.0010.502007-851-X-723-CTKP-ACD05-TKP-A-ST-0319-1Post-SDDESCAFFDismantle scaffolds after tubular strenthening at SD29.3541.9971.342012022035-851-X-024-ATKP-ASD05-TKP-A-ST-0320-1Pre-SDSCAFFErect scaffold for sump deck extension56.4096.81153.212045-851-Y-125-ATKP-ASD05-TKP-A-ST-0320-1Pre-SDHBTSet-up safety habitat for installation of Sump Deck Extension25.2050.0034.00109.202055-851-S-229-ATKP-ASD05-TKP-A-ST-0320-1Pre-SDINSTALLInstall horizontal tubular framings of sump deck extension25.2335.402.0023.8029.40115.832065-851-S-425-ATKP-ASD05-TKP-A-ST-0320-1Pre-SDNDTNDT at weldments of horizontal tubular framings of sump deck extension2.6010.0012.602075-851-S-230-ATKP-ASD05-TKP-A-ST-0320-1Pre-SDINSTALLInstall vertical columns (114.3 dia & 88.9 dia) of sump deck extension33.9351.822.0030.2044.89162.842085-851-S-426-ATKP-ASD05-TKP-A-ST-0320-1Pre-SDNDTNDT at weldments of vertical columns (114.3 dia & 88.9 dia for sump deck extension)3.8034.0037.802095-851-S-231-ATKP-ASD05-TKP-A-ST-0320-1Pre-SDINSTALLInstall top framings of sump deck extension49.1851.822.0030.2044.89178.092105-851-S-427-ATKP-ASD05-TKP-A-ST-0320-1Pre-SDNDTNDT at weldments of sump deck extension top framings3.8034.0037.802115-851-S-232-CTKP-ASD05-TKP-A-ST-0320-1Pre-SDINSTALLInstall gratings of sump deck extension31.0311.182.0014.0216.8575.082125-851-S-233-CTKP-ASD05-TKP-A-ST-0320-1Post-SDINSTALLInstall handrails of sump deck extension38.1022.102.0030.4022.10114.702135-851-S-428-CTKP-ASD05-TKP-A-ST-0320-1Post-SDNDTNDT at weldments of handrails for sump deck extension5.2062.0067.202147-851-Y-625-ATKP-ASD05-TKP-A-ST-0320-1Post-SDDHBTDismantle safety habitat after installation of Sump Deck Extension23.6035.0017.0075.602155-851-B-523-CTKP-ASD05-TKP-A-ST-0320-1Post-SDTPTouch-up painting at sump deck extension and associated members4.3044.0048.302167-851-X-724-CTKP-ACD05-TKP-A-ST-0320-1Post-SDDESCAFFDismantle scaffolds after sump deck extension38.7358.4097.132172182195-851-X-025-CTKP-ASD05-TKP-A-S-0403(R )Post-SD/DecomSCAFFErect Scaffolds for removal of existing service platform & vertical ladder at leg B146.1266.24112.362205-851-Y-126-CTKP-ASD05-TKP-A-S-0403(R )Post-SD/DecomHBTSet-up safety habitat for demolition of existing service platform (SD) and vertical ladder at leg B124.1038.0024.0086.102217-851-S-304-CTKP-ASD05-TKP-A-S-0403(R )Post-SD/DecomREMOVEDemolish existing service platform (SD) and vertical ladder at leg B148.2231.001.0029.40109.622227-851-Y-626-CTKP-ASD05-TKP-A-S-0403(R )Post-SD/DecomDHBTDismantle safety habitat after demolition of existing service platform (SD) and vertical ladder at leg B123.0529.0012.0064.052235-851-B-524-CTKP-ASD05-TKP-A-S-0403(R )Post-SD/DecomTPTouch-up painting after removal of existing SDV service platform2.6010.0012.602247-851-X-725-CTKP-ACD05-TKP-A-S-0403(R )Post-SD/DecomDESCAFFDismantle scaffolds after removal of existing service platform & vertical ladder at leg B132.8648.1280.982252262275-851-X-025-CTKP-ASDPost-SD/DecomSCAFFErect scaffolds for removal of gangway52.1668.32120.482287-851-S-305-CTKP-ASDPost-SD/DecomREMOVERemoval of gangway57.6557.652297-851-X-726-CTKP-ACDPost-SD/DecomDESCAFFDismantle scaffolds after gangway removal25.3144.1669.47