    Nissin Power Pack PS-300 is an externalpower booster for an electronic flash.By using this Power Pack PS-300 togetherwith the regular power source in theflash body, the recycle time to charge upis reduced to 1/4 compare to that withthe regular power source only.Futhermore , the maximum number offlashes is increased significantly.

    Two power supply sockets are providedso that two flashes can be used togetherat the same time.

    Before using the Power Pack PS-300,please read this operation manual andrefer your flash owners manual carefullyto get a better understanding of properoperation to enjoy flash photography.

    Nissin supplies two kinds of power supply cableaccording to the design of its plug to be connected intothe external power source service socket provided byrespective flash models. Please pay attention to thefollowing combination chat.

    This safety instruction refers important information touse the product safely and properly. Please read thefollowing instructions before using the product.

    1. Do not shoot more than 20 continuous fullpower flashes, which may damage the flashcircuit. Interrupt the shooting of flashes for 10to 15 minutes after such continuous shooting.

    2. When using one flash power supply cable only,the open socket is to be capped since it carriesa high voltage at its contacts.

    3. This power pack is effective only when theflash unit is operational. Do not remove thebatteries in the flash unit.

    4. For safety reason, the power pack can beswitched on only when the flash power supplycable is plugged into the socket on the powerpack main body.

    5. Using two flashes together requires moreenergy from the batteries and this may result i na longer recycle time than using one flash.

    6. The oscillating circuit is automatically switchedoff for safety protection when the power packmain body circuit is overheated. The flash isthen charged by its own batteries in the flashunit only and the recycle time becomes longer.The oscillation is suspended to cool down the

    power pack main body circuit for about 4 to 5minutes and it returns to the normal operationautomatically.

    Nissin Di866 CanonCanon 580EXII, 580EX, 550EX, MR-14EXand MT-24EX

    Cable with plug C for Canon type flash unit:

    Nissin Di866 NikonNikon SB900, SB800, SB80DX, SB28DX

    Cable with plug N for Nikon type flash unit:

    Power Pack Main Body

    Power Switch

    Power-on IndicationLamp

    Socket 1

    Socket 2

    Socket Cap

    Nomenclature

    MUST-READ

    CHARGING THE BATTERY

    Connect the power cable for AC adapter to the AC outletand plug the other end to the AC adapter. (fig.1)Connect the AC adapter to the socket of the battery.A red lamp on the charger turns on and this indicates thatcharging has been started. (fig.2)The battery will be fully charged in about 4 hours.The red lamp turns green when the battery is charged up.Disconnect the socket of the battery from the charger.Remove the charger from the outlet when not in use.

    Connect the flash power supply cable to the Power PackPS-300 and turn on the power switch.An indication lamp lights up green - orange - or redaccording to the power level set (fig.13).For quick recycling or for using two flashes together, thehighest power level red(marked Hi) is recommended.To save the battery energy or to reduce the load of the flashcapacitor, either low level green or medium level orange isrecommended.

    Switch the flash on, and the ready lamp of the flash willlight up within a second.A power indication lamp on the power pack is linked to theready lamp of theflash; it goes offwhile the flash ischarging, and itturns on when theflash becomesready.

    Turn the power switch off when not in use. In case that thepower switch remains on for long, the battery may bedamaged by over-discharge. Replace the battery in such acase by a new one.

    Be sure to use Nissins original battery.

    CONNECTING THE FLASH POWER SUPPLY CABLE

    Make sure to switch off both the PowerPack and the flash unit.

    DISCONNECTING THE FLASH POWER SUPPLY CABLE

    POWER ON

    You can use two flashes together at the same time.

    CONNECTING THE BATTERY

    Make sure to switchoff the Power PackPS-300.

    Open the flap of theleatherette case andpull out the powerpack main bodyfrom the case.

    Place the battery inthe batterycompartment andconnects its plug tothe socket of thepower pack mainbody firmly.

    Use the compatible flash power supply cable for your flash.Hold the connector of the flash power supply cable in front ofthe socket with bothguide marks on theconnector and on thesocket coinciding andinsert it to the socketstraight.You can plugthe connector either tosocket 1 or to socket 2.

    Cap the open socketwith the socket capstrapped at thesocket.

    Return the powerpack main body intothe leatherette caseand close the flap.

    Power Supply Cable

    Battery Compartment

    Battery

    Leatherette Case

    Belt Holder

    Strap

    AC Adapter and Power

    Cable for AC Adapter

    Thank you for purchasinga Nissin product

    WARNING

    This power pack contains high voltage electric parts. Do nottry to open or rework the power pack. Keep the power packaway from small children.Do not touch inside parts from opening when the unit wasbroken, e.g. by downfall. Return it back to the repair servicestation or the store where you bought it.Do not use the power pack nearby flammable gas, chemicalsor such liquids. It may cause fire or electric shock.Do not touch the power pack with wet hands. The power packcarries high voltage inside and it may cause an electric shock.Plug the battery firmly to the chargers sockets. Plugging thebattery loose may cause exothermic heat.

    CAUTIONS

    Do not leave or store the power pack at temperature over40C, such like in an automobile.The power pack is not water resistant. Keep it away from rain,snow and humidity. Do not use in wet places, such asbathrooms or in the rain.Do not use benzene, thinner or other alcoholic agents to cleanthe body and the leatherette case.Use Nissins original battery only. Do not use other batteries(battery cluster), otherwise it may damage the generator

    circuitry.Since the power source is stronger than the regular batterysource in the flash, repeated flash beyond the limit maydamage the flash. Some flashes provide a special circuit toprotect from overheat problem. Before using this power pack,read the safety instruction of the flash carefully and follow its

    This sign refers the danger or serious damage.

    This sign refers to a damage or defect.

    SAFTY INSTRUCTION

    fig.1

    fig.2

    fig.4

    fig.5

    fig.6

    fig.7

    fig.8

    Connect the plug atthe other end of thepower supply cableto the flash unit.

    fig.9

    fig.3

    Using one flash unit only

    These two flashes can be either same brand or the differentbrand mixed, as far as the power supply cable is compatibleto those respective flashes. (fig.10)

    Switch off both the power pack and the flash. Holdthe connector ofthe flash powersupply cable asshown and pull itoff.

    For connecting each of both cables, please follow theinstruction as given above (fig.7) for one flash usit only.Connect the plug of each flash power supply cable to thecorresponding flash u nit (fig.9).

    Make sure the batteries are correctly inserted in theflash unit when

    using withPower Pack.Without batteryin the flash, theflash does not

    work.

    The Power Pack PS-300 cannot be switched on ifthe flash power supply cable is not connected tothe Power Pack.

    fig.10

    fig.12

    fig.14

    fig.13

    Green(low)

    Using two flash units simultaneously

    Power source

    Battery life

    Charging time of

    battery

    Outlet

    Flash Power supplycable ( options )

    Flash recycle

    Number of flashes

    Dimensions (main body)

    Weight

    NiMH battery 7.2V/3,300mAh

    200 times of charge/discharge

    4 hours, approx.

    2 x DC 315V

    Type C or Type N

    Type C for Nissin Di866 model (Canon

    version) or Canons original flash withexternal power socket.

    Type N for Nissin Di866 model (Nikon

    version) or Nikons original flash withexternal power socket.

    1/4th of the recycle time by the regular

    batteries loaded in the flash unit.

    (e.g. approx. 0.7sec. for Nissin Di866,

    Canon EX580EX II, Nikon SB900)

    with switch position at Hi(lamp terns red)

    Note : No flash can be released, when

    batteries are not inserted in the flash unit.

    300 full flashes per charge

    110(W) x 200(H) x 35(D) mm / 4.3(W) x 7.8(H) x 1.3(D) inches

    980g with battery, w/o power supply cable.

    SPECIFICATIONS

    WARRANTY :

    In case of the following reasons of a defect, the warrantee may be void. For details, please look upthe respective condition on your warranty cardbecause it may vary from country to country.

    1. The product has not been used in accordance withthe instruction of the owner's manual.

    2. The product is been repaired or modified bysomebody else but an authorized repair service.

    3. The product has been used with the flash unit notapplicable (not compatible).

    4. Fault or defect has been caused by fire,earthquake, flood, public pollution and suchnatural disaster.

    5. The product has been stored or use in moisture,dust, extremely high temperature or such poorconditions.

    6. Scratch, blemish, crush or other sign of wear by aviolently use or treatment.

    7. Guarantee card without dealers name andaddress, without date of purchase and dealersstamp, or no guarantee card at all.

    Nissin Japan Ltd., www.nissin-japan.comNissin Marketing Ltd., www.nissindigital.com

    for CANON

    Type C Power Supply Cable Type N Power Supply Cable

    for NIKON

    fig.11

    Orange(medium) Red(high)

    Power Pack PS-300

    OPERATION MANUAL

    External Power Booster for an Electronic Flash Unit

    Design And Specifications Are Subject To Change Without Prior Notice

    With your Power Pack PS-300 you have received onecable of the desired kind of your flash unit. If you needanother one or two cables of the other kind, you canpurchase them from your dealer seperately.