Downflow/Horizontal Right or Downflow/Horizontal LeftInduced Draft Gas Furnace
PUB. NO. 22-1671-14
XR 80TDD1A060A9241B, TDD1A060A9361B, TDD1B060A9361B, TDD1B080A9361B, TDD1B080A9451B TDD1B100A9451B, TDD1C100A9481B, TDD1C100A9541BTDD1C120A9541B, TDD1D120A9601B, TDD1D140A9601B
Single-Stage Fan Assisted Combustion System
© 2016 Trane All Rights Reserved 2 22-1671-14
General Features
Natural Gas ModelsCentral Heating furnace designs are certified by the American and Cana-dian Gas Associations for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
Safe OperationThe Integrated System Control has solid state devices, which continuously moni-tor for presence of flame, when the sys-tem is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety.
Quick HeatingDurable, cycle tested, heavy gauge alu-minized steel heat exchanger quickly transfers heat to provide warm condi-tioned air to the structure.
BurnersMulti-port In-shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas.
Integrated System ControlExclusively designed operational pro-gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self-diagnostics for ease of service. Also contains connection points for E.A.C./humidifier.
AIR LEAKAGEAir leakage less than 2% of design airflow rate in accordance with ASHRAE 193.
Air DeliveryThe 4-speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.
StylingHeavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel fin-ish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass.
Features and General OperationThe XR 80 High Efficiency Gas Fur-nace employs an adaptive Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch.
22-1671-14 3
Contents
General Features 2Features and Benefits 4
Standard Equipment 4Optional Equipment 5
General Data 6TDD1A060A9241B 6TDD1A060A9361B 6TDD1B060A9361B 6TDD1B080A9361B 7TDD1B080A9451B 7TDD1B100A9451B 7TDD1C100A9481B 8TDD1C100A9541B 8TDD1C120A9541B 8TDD1D120A9601B 9TDD1D140A9601B 9
Performance Data 10Electrical Data 12Field Wiring 14Dimensions 16
4 22-1671-14
Features and Benefits
• Power supply 115/1/60
• Multi-port In-shot burners
• Integrated solid state control with self- diagnostics
• Silicon Nitride hot surface igniter with adaptive heat up
• Complete front service access
• Heavy gauge aluminized steel heat exchanger
• Slide out blower assembly
• Blower door safety switch
• Direct drive, 4-speed motor
• Optional L.P. conversion kit
• Common vent
• Left and right side knockout for venting
• Selectable cooling fan off delay elimi-nates need for BAY24X045 time delay relay
• Quiet slow opening gas valve
• Downflow convertible to horizontal on left or right side
• Insulated blower compartment
• Accessory hook-up capability – Hum and EAC
• Quiet induced draft blower
• Left/right gas connection
• 24 volt fuse
• Manual reset flame rollout switches
XR 80 Downflow/Horizontal Right or LeftStandard Equipment
22-1671-14 5
Features and Benefits
Optional EquipmentThermostat ............................................................................................................................................................... BAYSTAT388 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ...............................................................................AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................ BAYSTAT305 [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ............................................................. TAYSTAT300C [ ]Propane Conversion Kit ......................................................................................................................................... BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) ......................................................TFM145A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ......................................................TFM175A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ............................................................TFM210A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ......................................................TFM245A9FR1 [ ] Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace)..............................................TFP175A9FR01 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ....................................................TFP210A9FR01 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace)..............................................TFP245A9FR01 [ ]Coil Enclosure (14-1/2" Wide Cabinets) .........................................................................................................BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ....................................................................................................... BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) .............................................................................................................. BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ....................................................................................................... BAYCLE24A2430A [ ]Filter Access Door Kit .............................................................................................................................................. BAYFLTR206 [ ]Downflow Subbase .................................................................................................................................................. BAYBASE205 [ ]High Altitude Pressure Switch Kit .............................................................................................................................BAYHALT248 [ ]
6 22-1671-14
General Data
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
TDD1A060A9241B
Downflow / Horizontal
60,00048,00080.0
35 - 65
DIRECT10 x 7
14
See Fan Performance Table1/5
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot3
115/1/605.515
1/2
H x W x D41 x 15-1/2 x 29-1/2
129 / 119
TDD1A060A9361B
Downflow / Horizontal
60,00048,00080.0
30 - 60
DIRECT11 x 7
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot3
115/1/6011.615
1/2
H x W x D41 x 15-1/2 x 29-1/2
129 / 119
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea
level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TDD1B060A9361B
Downflow / Horizontal
60,00048,00080.0
30 - 60
DIRECT10 x 7
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot3
115/1/6011.615
1/2
H x W x D41 x 18-1/2 x 29-1/2
134 / 124
22-1671-14 7
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
General Data
TDD1B080A9451B
Downflow / Horizontal
80,00064,00080.0
35 - 65
DIRECT10 x 8
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot4
115/1/609.815
1/2
H x W x D41 x 18-1/2 x 29-1/2
146 / 135
TDD1B080A9361B
Downflow / Horizontal
80,00064,00080.0
35 - 65
DIRECT10 x 7
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot4
115/1/609.015
1/2
H x W x D41 x 18-1/2 x 29-1/2
146 / 135
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea
level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TDD1B100A9451B
Downflow / Horizontal
100,00080,00080.0
35 - 65
DIRECT10 x 8
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50 - 3200115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot5
115/1/609.815
1/2
H x W x D41 x 18-1/2 x 29-1/2
156 / 145
8 22-1671-14
General Data
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea
level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TDD1C100A9481B
Downflow / Horizontal
100,00080,00080.0
35 - 65
DIRECT10 x 8
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot5
115/1/6011.615
1/2
H x W x D41 x 22 x 29-1/2
166 / 154
TDD1C100A9541B
Downflow / Horizontal
100,00081,00080.0
30 - 60
DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot5
115/1/6013.420
1/2
H x W x D41 x 22 x 29-1/2
167 / 155
TDD1C120A9541B
Downflow / Horizontal
120,00096,00080.0
35 - 65
DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot6
115/1/6013.420
1/2
H x W x D41 x 22 x 29-1/2
170 / 158
22-1671-14 9
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
General Data
TDD1D140A9601B
Downflow / Horizontal
140,000113,000
80.045 - 75
DIRECT11 x 10
14
See Fan Performance Table3/4
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
7 — 457 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot7
115/1/6013.820
1/2
H x W x D41 x 25_-1/2 x 28
196 / 183
TDD1D120A9601B
Downflow / Horizontal
120,00096,00080.0
35 - 65
DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot6
115/1/6013.420
1/2
H x W x D41 x 25-1/2 x 29-1/2
189 / 176
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea
level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
10 22-1671-14
Performance Data
* May be "A" or "T"
FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.)
MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90
*DD1A060A9241B4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
12001025838722
1155988808689
1111951779656
1056905742618
1001859704579
924797646528
848735588478
774646502376
701558415275
*DD1A060A9361B*DD1B060A9361B
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
148013021115956
142912761100947
137512291070918
131811881035888
128211411000859
11001088965824
11121024918788
1029953859741
959882790682
*DD1B080A9361B4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
152313171123942
149613071119943
146312611106931
142012421082920
136912231056898
131011751016868
12431122976833
11721060930795
11001000880760
*DD1B080A9451B4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
1798138412101005
175013671150970
169213331108808
164213001075775
157512751042767
150012331008733
14251192967700
13251142925675
12251083867617
*DD1B100A9451B4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
176713821130840
173113541138831
166913231115815
161512921085792
154612541054762
146912071015731
13921177977700
13001108938654
11461038877625
*DD1C100A9481B4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
1965164514071202
1915162713981208
1865160513871205
1805157513751195
1740153513471166
1670148213181140
1587142112751105
1500133011901045
137012201095970
*DD1B100A9541B4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
2165196217051492
2113192716881467
2060189116711442
1995183916361414
1929178616001385
1842172415471346
1755166214921307
1674158114351243
1593150013771179
*DD1C120A9541B4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
2100191716721485
2049188716561478
1997185716391470
1958184216311448
1918182716231426
1852175115601388
1785167414961349
1695159414271278
1604151413581207
*DD1D120A9601B4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
2241198117211476
2202196217051466
2163194216881456
2106190416711440
2049186616531423
1979180516111392
1908174315691361
1804168015151302
1700161714611243
*DD1D140A9601B4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
2377211518061527
2321208117931507
2265204617791486
2199199217381473
2133193816961459
2050187216551422
1967180516141384
1877172715561329
1786164914971273
22-1671-14 11
Performance Data
CFM VS. TEMPERATURE RISE
MODEL700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
*DD1A060A9241B 63 56 49 44 40
*DD1A060A9361B 56 49 44 40 37 34 32
*DD1B060A9361B 56 49 44 40 37 34 32
*DD1B080A9361B 59 54 49 46 42
*DD1B080A9451B 64 57 52 48 44 41
*DD1B100A9451B 62 57 53 49 46 44 41
*DD1C100A9481B 62 57 53 49 46 44 41 39 37
*DD1C100A9541B 62 57 53 49 46 44 41 39 37 35 34 32 31
*DD1C120A9541B 59 56 52 49 47 44 42 40
*DD1D120A9601B 59 56 52 49 47 44 42 40
*DD1D140A9601B 69 65 61 58 55 52 49 47 45
* First letter may be "A" or "T" From C341712 Sh. 1 Rev. 03
12 22-1671-14
(continued on next page)
WIRING DIAGRAM
From Dwg. D342568P02
22-1671-14 13
SCHEMATIC DIAGRAM
From Dwg. D342568P02
14 22-1671-14
Field Wiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg. 21B341437 Rev. 1
From Dwg. 21B341436 Rev. 1
22-1671-14 15
Field Wiring
From Dwg. 21B341423 Rev. 1
From Dwg. 21B341422 Rev. 1
Trane 6200 Troup HighwayTyler, TX 75707www.trane.com
Since The Trane Company has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.
Literature Order Number 22-1671-14
File Number 22-1671-14
Supersedes 22-1671-13
Date 05/16
TD
D1
OU
TL
INE
DR
AW
ING
(AL
L D
IME
NS
ION
S A
RE
IN IN
CH
ES
)
1-1/
2” X
2-1
/2”
OVA
LG
AS
CO
NN
ECTI
ON
Ø 1
-5/8
” H
OLE
WIT
H P
LUG
Ø 1
-5/8
” H
OLE
W
ITH
PLU
G (3
)
Ø 7
/8”
HO
LE W
ITH
PLU
GEL
ECTR
ICA
L C
ON
NEC
TIO
N
(ALT
ERN
ATE)
MO
DE
LD
IM "
A"
DIM
"B
"D
IM "
C"
DIM
"D
"
*DD
1A06
0A92
41B
, *D
D1A
060A
9361
B14
-1/2
"9-
5/8"
13-1
/4"
13"
*DD
1B06
0A93
61B
, *D
D1B
080A
9361
B*D
D1B
080A
9451
B, *
DD
1B10
0A94
51B
17-1
/2"
9-5/
8"16
-1/4
"16
"
*DD
1C10
0A94
81B
, *D
D1C
100A
9541
B*D
D1C
120A
9541
B21
"13
-1/1
6"19
-3/4
"19
-1/2
"
*DD
1D12
0A96
01B
, *D
D1D
140A
9601
B24
-1/2
"15
-5/1
6"23
-1/4
"23
"