Downflow/Horizontal Right Induced Draft Gas Furnace

American Standard 80ADE1A060A9361A, ADE1B060A9361AADE1B080A9451A, ADE1B100A9451AADE1C100A9601A, ADE1D120A9601ASingle-Stage Fan Assisted Combustion System

PUB. NO. 12-1235-05

Page 2: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

2 Pub. No. 12-1235-05

GeneralFeatures

© 2015 American Standard Heating & Air Conditioning

NATURAL GAS MODELSCentral Heating furnace designs are certified by the American Gas Associa-tion for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.

SAFE OPERATIONThe Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of opera-tion. Dual solenoid combination gas valve and regulator provide extra safety.

QUICK HEATINGDurable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure.

BURNERSMultiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas.

INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connec-tion points for E.A.C./humidifier.

AIR DELIVERYThe 4-speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.

STYLINGHeavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchang-er section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient opera-tion due to the excellent acoustical and insulating qualities of fiberglass. Alter-nate bottom, left or right side return air connection provision capability.

FEATURES AND GENERAL OPERATIONThe American Standard 80 Furnace employs an Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermo-stat. Complete front service access.

a. Low energy power venter b. Vent proving pressure switch.

Page 3: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

3Pub. No. 12-1235-05

Contents

Feature Summary

Features and Benefits Standard EquipmentOptional Equipment

General Data ADE1A060A9361AADE1B060A9361AADE1B080A9451AADE1B100A9451AADE1C100A9601AADE1D120A9601A

Performance Data

Field Wiring

Electrical Data

Dimensions

2

4

5

7

8

9

11

Page 4: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

4 Pub. No. 12-1235-05

American Standard 80 FURNACE OPTIONAL ACCESSORIES

American Standard 80 FURNACE STANDARD EQUIPMENT

Featuresand Benefits

•Downflow/Horizontal•Powersupply115/1/60•Multi-portIn-shotburners•SiliconNitridehotsurfaceigniterwith

adaptive heat up•Heavygauge,wrap-aroundsteelcabi-

net•Completefrontserviceaccess

•Heavygaugealuminizedsteelheatexchanger

•Slideoutblowerassembly•Directdrive,4-speedmotors•Blowerdoorsafetyswitch•OptionalL.P.conversionkit•Commonventcapability

•Selectablecoolingfanoffdelayoptioneliminates need for BAY24X045 time delay relay

•Innerblowerdoorpanelondownflowmodels

•3-wayventoptionondownflowmodels(top, right, or left)

OPTIONAL EQUIPMENT (Check mark [✓] indicates accessories included).For Comfort Controls, See price book pages .............................................................................................................................. [ ]AccuCleanTM Whole House Air Cleaner (14-1/2" Wide, Upflow / Side Return Furnace) ............................... AFD145ALFR000A [ ]AccuCleanTM Whole House Air Cleaner (17-1/2" Wide, Upflow / Side Return Furnace) ............................... AFD175ALFR000A [ ]AccuCleanTM Whole House Air Cleaner (21" Wide, Upflow / Side Return Furnace) ..................................... AFD210ALFR000A [ ]AccuCleanTM Whole House Air Cleaner (24-1/2" Wide, Upflow / Side Return Furnace) ............................... AFD245ALFR000A [ ]AccuCleanTM Whole House Air Cleaner (14-1/2" Wide, Downflow Furnace) ................................................AFD14DALFR000A [ ]AccuCleanTM Whole House Air Cleaner (17-1/2" Wide, Downflow Furnace) ................................................AFD17DALFR000A [ ]AccuCleanTM Whole House Air Cleaner (21" Wide, Downflow Furnace) ......................................................AFD21DALFR000A [ ]AccuCleanTM Whole House Air Cleaner (24-1/2" Wide, Downflow Furnace) ................................................AFD24DALFR000A [ ]Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .................................................................... TFM145A9FR0 [ ]Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .................................................................... TFM175A9FR0 [ ]Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ........................................................................... TFM210A9FR0 [ ]Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .................................................................... TFM245A9FR0 [ ]Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ..............................................................TFP145A9FR0 [ ]Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ..............................................................TFP175A9FR0 [ ]Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ....................................................................TFP210A9FR0 [ ]Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ..............................................................TFP245A9FR0 [ ]Coil Enclosure (14-1/2" Wide Cabinets) ........................................................................................................ BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ........................................................................................................ BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) .............................................................................................................. BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ........................................................................................................ BAYCLE24A2430A [ ]Filter Rack Kit ......................................................................................................................................................BAYRACK960A [ ]High Altitude Switch ................................................................................................................................................ BAYHALT248 [ ]Downflow Subbase .................................................................................................................................................BAYBASE205 [ ]Propane Conversion Kit ........................................................................................................................................BAYLPKT210B [ ]Propane Conversion Kit (With Stainless Steel burners) .......................................................................................BAYLPSS210B [ ]Masonry Chimney Vent Kit .................................................................................................................................. BAYVENT800B [ ]Cleanable Filter (14.5" / 17.5" wide upflow models) ................................................................................................BAYFLTR317 [ ]Cleanable Filter (21" wide upflow models) ..............................................................................................................BAYFLTR321 [ ]Cleanable Filter (24.5" wide upflow models) ...........................................................................................................BAYFLTR324 [ ]Filter Access Door Kit (Downflow models only) .......................................................................................................BAYFLTR206 [ ]

Page 5: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

5Pub. No. 12-1235-05

PRODUCT SPECIFICATIONS 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

GeneralData

1 Central Furnace heating designs are certified to ANSI Z21.47 and CSA 2.3.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

ADE1A060A9361A

Downflow / Horizontal

60,00048,00080.0

30 - 60

Direct11 x 7

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

2 - 14x20 - 1in.

4 Round

Alum. Steel

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot3

115/1/6011.215

1/2

H x W x D41-3/4 x 16-1/2 x 30-1/2

129 / 119

ADE1B080A9451A

Downflow / Horizontal

80,00064,00080.0

35 - 65

Direct10 x 8

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

2 - 14x20 - 1in.

4 Round

Alum. Steel

20

4 — 454 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot4

115/1/609.115

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

146 / 135

ADE1B060A9361A

Downflow / Horizontal

60,00048,00080.0

30 - 60

Direct10 x 7

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

2 - 14x20 - 1in.

4 Round

Alum. Steel

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot3

115/1/60915

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

135 / 125

Page 6: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

6 Pub. No. 12-1235-05

GeneralData

PRODUCT SPECIFICATIONS 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

1 Central Furnace heating designs are certified to ANSI Z21.47 and CSA 2.3.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

ADE1B100A9451A

Downflow / Horizontal

100,00080,00080.0

35 - 65

Direct10 x 8

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

2 - 14x20 - 1in

4 Round

Alum. Steel

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot5

115/1/609.115

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

156 / 145

ADE1D120A9601A

Downflow / Horizontal

120,00096,00080.0

30 - 60

Direct11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

2 - 16x20 - 1in

4 Round

Alum. Steel

20

6 — 456 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot6

115/1/6012.815

1/2

H x W x D41-3/4 x 26-1/2 x 30-1/2

189 / 176

ADE1C100A9601A

Downflow / Horizontal

100,00081,00080.0

30 - 60

Direct11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

2 - 16x20 - 1in

4 Round

Alum. Steel

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot5

115/1/6012.815

1/2

H x W x D41-3/4 x 23 x 30-1/2

167 / 155

Page 7: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

7Pub. No. 12-1235-05

PerformanceData

FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.)

MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90

ADE1A060A9361A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

148013021115956

142912761100947

137612291070918

131811881035888

128211411000859

11881088965824

11121024918788

1029953859741

959882790682

ADE1B060A9361A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1644146712521025

1593143112161022

1525138311941003

147313321169986

140812771122955

131612091079910

126911371011862

11781064933793

1056970840672

ADE1B080A9451A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1798138412101005

175013671150970

169213331108808

164213001075775

157512751042767

150012331008733

14251192967700

13251142925675

12251083867617

ADE1B100A9451A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

176713821130840

173113541138831

166913231115815

161512921085792

154612541054762

146912071015731

13921177977700

13001108938654

11461038877625

ADE1C100A9601A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2165196217051492

2113192716881467

2060189116711442

1995183916361414

1929178616001385

1842172415471346

1755166214921307

1674158114351243

1593150013771179

ADE1D120A9601A4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2241198117211476

2202196217051466

2163194216881456

2106190416711440

2049186616531423

1979180516111392

1908174315691361

1804168015151302

1700161714611243

From D341548 Rev. 1

CFM VS. TEMPERATURE RISE

MODEL CFM (CUBIC FEET PER MINUTE)

500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400

ADE1A060A9361A 56 49 44 40 37 34 32

ADE1B060A9361A 56 49 44 40 37 34 32

ADE1B080A9451A 64 57 52 48 44 41

ADE1B100A9451A 62 57 53 49 46 44 41

ADE1C100A9601A 62 57 53 49 46 44 41 39 37 35 34 32 31

ADE1D120A9601A 59 56 52 49 47 44 42 40

From C330671 Sh. 3 Rev. 10

Page 8: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

8 Pub. No. 12-1235-05

Field Wiring

SEE NOTE 5

From Dwg. B342026 Rev. 0

FURNACE

SEE NOTE 6

B/CB/C

TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES

FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE1 STAGE HEATING

USING A 1 STAGE HEATING THERMOSTATNO COOLING

OUTDOOR UNIT (NO TRANSFORMER)

SEE NOTE 5

From Dwg. B342023 Rev. 0

FURNACE

B/CB/C

TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES

FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE1 STAGE HEATING, 1 STAGE COOLING

USING A 1 STAGE HEATING, 1 STAGE COOLING THERMOSTAT(OUTDOOR SECTION WITHOUT TRANSFORMER)

FIELD WIRING DIAGRAM FOR HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER)

FIELD WIRING DIAGRAM FOR HEATING ONLY

Page 9: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

9Pub. No. 12-1235-05

WIRING DIAGRAM FOR ADE1 FURNACES

ElectricalData

From Dwg. D342780P05

Page 10: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

10 Pub. No. 12-1235-05

SCHEMATIC DIAGRAM FOR ADE1 FURNACES

ElectricalData

From Dwg. D342780P05

Page 11: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

11Pub. No. 12-1235-05

Dimensions

AD

E1

OU

TL

INE

DR

AW

ING

(AL

L D

IME

NS

ION

S A

RE

IN IN

CH

ES

)

1-1/

2” X

2-1

/2”

OVA

LG

AS

CO

NN

ECTI

ON

Ø 1

-5/8

” H

OLE

WIT

H P

LUG

Ø 1

-5/8

” H

OLE

W

ITH

PLU

G (3

)

Ø 7

/8”

HO

LE W

ITH

PLU

GEL

ECTR

ICA

L C

ON

NEC

TIO

N

(ALT

ERN

ATE)

MO

DE

LD

IM "

A"

DIM

"B

"D

IM "

C"

DIM

"D

"

*DE

1A06

0A93

61A

14-1

/2"

9-5/

8"13

-1/4

"13

"

*DE

1B06

0A93

61A

*DE

1B08

0A94

51A

*DE

1B10

0A94

51A

17-1

/2"

9-5/

8"16

-1/4

"16

"

*DE

1C10

0A96

01A

21"

13-1

/16"

19-3

/4"

19-1

/2"

*DE

1D12

0A96

01A

24-1

/2"

15-5

/16"

23-1

/4"

23"

* P

refix

lette

r m

ay b

e "A

" or

"T

"**

Suf

fix le

tter

may

be

"A"

thro

ugh

"Z"

Page 12: Downflow/Horizontal Right Induced Draft Gas Furnace ... · Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A9451A,

Since American Standard Heating & Air Conditioning has a policy of continuous product improvement, it reserves the right to change design and specifications without notice.

American StandardHeating & Air Conditioning6200 Troup HighwayTyler, TX 75707

04/15