  • Upflow/Horizontal LeftDownflow/Horizontal RightCondensing, Direct VentGas-Fired FurnaceFREEDOM 90 SINGLE STAGEAUX1B040A9241A, AUX1B060A9241A,AUX1B060A9361A, AUX1B080A9241A,AUX1B080A9421A, AUX1C080A9601A,AUX1C100A9361A, AUX1C100A9481A,AUX1D100A9601A, AUX1D120A9601AADX1B040A9241A, ADX1B060A9361A,ADX1B080A9421A, ADX1C100A9481A,ADX1D120A9601A

    Single-Stage Fan AssistedCombustion System

    PUB. NO. 12-1234-06

  • 2009 American Standard Heating & Air Conditioning 2 22-1234-05

    GeneralFeatures

    NATURAL GAS MODELSCentral Heating furnace designs arecertified by the American Gas Associationfor both natural and L.P. gas. Limitsetting and rating data were establishedand approved under standard ratingconditions using American NationalStandards Institute standards.

    SAFE OPERATIONThe Integrated System Control has solidstate devices, which continuously monitorfor presence of flame, when the system isin the heating mode of operation. Dualsolenoid combination gas valve andregulator provide extra safety.

    QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to increaseefficiency and provide a positive dis-charge of gas fumes to the outside.

    BURNERSMultiport Inshot burners will give years ofquiet and efficient service. All modelscan be converted to L.P. gas withoutchanging burners.

    INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self diagnostics forease of service. Also contains connec-tion points for E.A.C./humidifier.

    AIR DELIVERYThe four speed, direct drive blowermotor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speeds ondemand from room thermostat. Theblower door safety switch will prevent orterminate furnace operation when theblower door is removed.

    STYLINGHeavy gauge steel and wrap-aroundcabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heat ex-changer section of the cabinet is com-pletely lined with foil faced fiberglassinsulation. This results in quiet andefficient operation due to the excellentacoustical and insulating qualities offiberglass. Built-in bottom pan andalternate bottom, left or right side returnair connection provision.

    FEATURES ANDGENERAL OPERATIONThe FREEDOM 90 Single Stage HighEfficiency Gas Furnaces employ aSilicon Nitride Hot Surface Ignitionsystem, which eliminates the waste of aconstant burning pilot. The integratedsystem control lights the main burnersupon a demand for heat from the roomthermostat. Complete front serviceaccess.

    a. Low energy power venter

    b. Vent proving pressure switch.

  • 22-1234-05 3

    Contents

    General Features 2

    Features and Benefits 3FREEDOM 90 Standard Equipment 3FREEDOM 90 Optional Equipment 4

    General Data 5AUX1B040A9241A 5AUX1B060A9241A 5AUX1B060A9361A 5AUX1B080A9241A 5AUX1B080A9421A 5AUX1C080A9601A 5AUX1C100A9361A 5AUX1C100A9481A 6AUX1D100A9601A 6AUX1D120A9601A 6ADX1B040A9241A 7ADX1B060A9361A 7ADX1B080A9421A 7ADX1C100A9481A 8ADX1D120A9601A 8

    Performance Data 9

    Electrical Data 11

    Field Wiring 13

    Twinning Field Wiring 14

    Dimensions 15

    Featuresand Benefits

    FREEDOM 90Standard Equipment

    Power supply 115/1/60

    Convertible to horizontal left

    Type 29-4C stainless steel second-ary heat exchanger

    Inner blower doors

    Direct drive, 4-speed motors

    Silicon Nitride igniter with adaptiveheat up

    Accessory hook-up capability Hum and EAC

    Quiet induced draft blower

    Blower door safety switch

    Dual solenoid combination gas valve& regulator

    PVC venting 1 or 2 pipe vent option

    Left/right gas connection

    Selectable cooling fan off delayeliminates need for BAY24X045 timedelay relay

    Single wire twinning

    Integrated solid state control with self-diagnostics

    24 volt fuse

    Manual reset burner box limit

    Optional extended warranties

  • 4 12-1234-06

    Features andBenefits

    FREEDOM 90 Single Stage Optional EquipmentComfort Control, XL803, Programmable 7 Day, 3-Ht, 2-Cl ........................................................................... TCONT803AS32DA [ ]Comfort Control, XR402, Electric, 3-Ht, 2-Cl (Non-programmable) .............................................................. TCONT402AN32DA [ ]For additional comfort control choices, see the product catalog or quick select handbookPropane Conversion Kit ....................................................................................................................................... BAYLPKT210B [ ]Propane Conversion Kit (stainless steel burners) ................................................................................................ BAYLPSS210B [ ]Wall Mount Flange 3" ............................................................................................................................................. BAY96X147 [ ]Wall Mount Flange 2" ............................................................................................................................................. BAY96X148 [ ]Downflow Subbase ................................................................................................................................................ BAYBASE205 [ ]Filter Access Door Kit .............................................................................................................................................. BAYFLTR206 [ ]Side Filter Rack ....................................................................................................................................................... BAYFLTR200 [ ]High Altitude Pressure Switch Kit TUX040,100C960D; TDX040C .......................................................................... BAYHALT230 [ ]High Altitude Pressure Switch Kit TUX060C ........................................................................................................... BAYHALT231 [ ]High Altitude Pressure Switch Kit TUX080C ........................................................................................................... BAYHALT232 [ ]High Altitude Pressure Switch Kit TUX100C948D,120C; TDX080,120C ................................................................. BAYHALT233 [ ]High Altitude Pressure Switch Kit TDX100C ........................................................................................................... BAYHALT234 [ ]High Altitude Pressure Switch Kit TDX060C ........................................................................................................... BAYHALT241 [ ]Concentric Vent Kit .............................................................................................................................................. BAYVENT100A [ ]Sidewall Vent Termination Kit .............................................................................................................................. BAYVENT200B [ ]Manufactured/Mobile Home Kit ...........................................................................................................................BAYMFGH100A [ ]

  • 12-1234-06 5

    Product Specifications 1MODEL

    TYPE

    RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) F.

    BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

    COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

    FILTER Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

    VENT PIPE DIA. Min (In.) 56

    HEAT EXCHANGERType-Fired

    -UnfiredGauge (Fired)

    ORIFICES MainNat. Gas. Qty. Drill SizeL.P. Gas Qty. Drill Size

    GAS VALVE

    PILOT SAFETY DEVICEType

    BURNERS TypeNumber

    POWER CONN. V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

    PIPE CONN. SIZE (IN.)

    DIMENSIONSCrated (In.)

    WEIGHTShipping (Lbs.) / Net (Lbs)

    GeneralData

    AUX1B040A9241A

    Upflow / Horizontal

    40,00038,00095.0

    30 - 60

    DIRECT9 x 7

    14

    See Fan Performance Table1/5

    1075115/1/60

    CentrifugalDirect - 1

    1/55 - 3000115/1/60

    1.0

    NoHigh Velocity

    1 - 17x25 - 1in.

    2 Round

    Aluminized Steel - Type I

    20

    2 452 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multiport Inshot2

    115/1/604.815

    1/2

    H x W x D41-3/4 x 19-1/2 x 30-1/2

    139 / 129

    AUX1B060A9361A

    Upflow / Horizontal

    60,00056,00092.1

    30 - 60

    DIRECT10 x 7

    14

    See Fan Performance Table1/3

    1075115/1/60

    CentrifugalDirect - 1

    1/55 - 3000115/1/60

    1.0

    NoHigh Velocity

    1 - 17x25 - 1in.

    2 Round

    Aluminized Steel - Type I

    20

    3 453 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multiport Inshot3

    115/1/608.415

    1/2

    H x W x D41-3/4 x 19-1/2 x 30-1/2

    150 / 140

    AUX1B060A9241A

    Upflow / Horizontal

    60,00056,00092.1

    30 - 60

    DIRECT9 x 7

    14

    See Fan Performance Table1/3

    1075115/1/60

    CentrifugalDirect - 1

    1/55 - 3000115/1/60

    1.0

    NoHigh Velocity

    1 - 17x25 - 1in.

    2 Round

    Aluminized Steel - Type I

    20

    3 453 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multiport Inshot3

    115/1/609.215

    1/2

    H x W x D41-3/4 x 19-1/2 x 30-1/2

    150 / 140

    AUX1B080A9241A

    Upflow / Horizontal

    80,00074,00092.1

    35 - 65

    DIRECT10 x 7

    14

    See Fan Performance Table1/3

    1075115/1/60