SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. January 2019 18-CE04D1-1B-EN Upflow/Downflow/Horizontal Gas-Fired, 1–Stage and 2–Stage Induced Draft Furnaces with High Efficiency Motor Upflow, Downflow, Horizontal Right/Left Single Stage S8X1A026M2PSAA S8X1A040M3PSAA S8X1B040M2PSAA S8X1B060M3PSAA S8X1B060M4PSAA S8X1B080M4PSAA S8X1C080M5PSAA S8X1C100M5PSAA S8X1D120M5PSAA Two Stage S8X2A040M3PSAA S8X2B060M3PSAA S8X2B060M4PSAA S8X2B080M4PSAA S8X2C080M5PSAA S8X2C100M5PSAA S8X2D120M5PSAA S8X1 S8X2 Note: This installer’s Guide is used for multiple furnace families. Models may have a “T” in the 12th digit designating they meet California less than 40 ng/J (NOx) emissions requirements. Note: Graphics in this document are for representation only. Actual model may differ in appearance. 18-CE04D1-1A-EN Installer’s Guide

Installer's Guide - Upflow/Horizontal Left/Right, Downflow

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

SSAAFFEETTYY WWAARRNNIINNGGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, andair-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or alteredequipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in theliterature and on the tags, stickers, and labels that are attached to the equipment.

January 2019 1188--CCEE0044DD11--11BB--EENN

Upflow/Downflow/HorizontalGas-Fired, 1–Stage and 2–Stage Induced DraftFurnaces with High Efficiency MotorUUppffllooww,, DDoowwnnffllooww,, HHoorriizzoonnttaall RRiigghhtt//LLeefftt

Single StageS8X1A026M2PSAAS8X1A040M3PSAAS8X1B040M2PSAAS8X1B060M3PSAAS8X1B060M4PSAAS8X1B080M4PSAAS8X1C080M5PSAAS8X1C100M5PSAAS8X1D120M5PSAA

Two StageS8X2A040M3PSAAS8X2B060M3PSAAS8X2B060M4PSAAS8X2B080M4PSAAS8X2C080M5PSAAS8X2C100M5PSAAS8X2D120M5PSAA

S8X1

S8X2

NNoottee:: This installer’s Guide is used for multiple furnace families. Modelsmay have a “T” in the 12th digit designating they meet California lessthan 40 ng/J (NOx) emissions requirements.

NNoottee:: Graphics in this document are forrepresentation only. Actual model may

differ in appearance.

18-CE04D1-1A-EN

Installer’s Guide

Page 2: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

©2018 Ingersoll Rand 18-CE04D1-1B-EN

SAFETY SECTION NON-CONDENSING FURNACESIInnggeerrssoollll RRaanndd hhaass aa ppoolliiccyy ooff ccoonnttiinnuuoouuss pprroodduuccttaanndd pprroodduucctt ddaattaa iimmpprroovveemmeenntt aanndd iitt rreesseerrvveess tthheerriigghhtt ttoo cchhaannggee ddeessiiggnn aanndd ssppeecciiffiiccaattiioonnss wwiitthhoouuttnnoottiiccee..

IImmppoorrttaanntt:: — This document pack contains a wiringdiagram and service information. This iscustomer property and is to remain withthis unit. Please return to serviceinformation pack upon completion of work.

WWAARRNNIINNGGFFIIRREE OORR EEXXPPLLOOSSIIOONN HHAAZZAARRDD!!

Failure to follow safety warnings exactlycould result in a fire or explosion causingproperty damage, personal injury or lossof life.

—— DDoo nnoott ssttoorree oorr uussee ggaassoolliinnee oorr ootthheerrffllaammmmaabbllee vvaappoorrss aanndd lliiqquuiiddss iinn tthhee vviicciinniittyy oofftthhiiss oorr aannyy ootthheerr aapppplliiaannccee.. —— WWHHAATT TTOO DDOO IIFFYYOOUU SSMMEELLLL GGAASS

•• DDoo nnoott ttrryy ttoo lliigghhtt aannyy aapppplliiaannccee..

•• DDoo nnoott ttoouucchh aannyy eelleeccttrriiccaall sswwiittcchh;;ddoo nnoott uusseeaannyy pphhoonnee iinn yyoouurr bbuuiillddiinngg..

•• IImmmmeeddiiaatteellyy ccaallll yyoouurr ggaass ssuupppplliieerr ffrroomm aanneeiigghhbboorr’’ss pphhoonnee.. FFoollllooww tthhee ggaass ssuupppplliieerr''ssiinnssttrruuccttiioonnss..

•• IIff yyoouu ccaannnnoott rreeaacchh yyoouurr ggaass ssuupppplliieerr,, ccaalllltthhee ffiirree ddeeppaarrttmmeenntt..

—— IInnssttaallllaattiioonn aanndd sseerrvviiccee mmuusstt bbee ppeerrffoorrmmeedd bbyyaa qquuaalliiffiieedd iinnssttaalllleerr,, sseerrvviiccee aaggeennccyy,, oorr tthhee ggaassssuupppplliieerr..

WWAARRNNIINNGGEEXXPPLLOOSSIIOONN HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, ppeerrssoonnaall iinnjjuurryy oorr ddeeaatthh..IInnssttaallll aa ggaass ddeetteeccttiinngg wwaarrnniinngg ddeevviiccee iinn ccaassee ooff aaggaass lleeaakk.. NNOOTTEE:: TThhee mmaannuuffaaccttuurreerr ooff yyoouurr ffuurrnnaacceeddooeess nnoott tteesstt aannyy ddeetteeccttoorrss aanndd mmaakkeess nnoorreepprreesseennttaattiioonnss rreeggaarrddiinngg aannyy bbrraanndd oorr ttyyppee ooffddeetteeccttoorr..

WWAARRNNIINNGGFFIIRREE OORR EEXXPPLLOOSSIIOONN HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhee ssaaffeettyy wwaarrnniinnggss eexxaaccttllyy ccoouullddrreessuulltt iinn sseerriioouuss iinnjjuurryy,, ddeeaatthh,, oorr pprrooppeerrttyyddaammaaggee..NNeevveerr tteesstt ffoorr ggaass lleeaakkss wwiitthh aann ooppeenn ffllaammee.. UUssee aaccoommmmeerrcciiaallllyy aavvaaiillaabbllee ssooaapp ssoolluuttiioonn mmaaddeessppeecciiffiiccaallllyy ffoorr tthhee ddeetteeccttiioonn ooff lleeaakkss ttoo cchheecckk aallllccoonnnneeccttiioonnss.. AA ffiirree oorr eexxpplloossiioonn mmaayy rreessuullttccaauussiinngg pprrooppeerrttyy ddaammaaggee,, ppeerrssoonnaall iinnjjuurryy,, oorr lloossssooff lliiffee..

WWAARRNNIINNGGEELLEECCTTRRIICCAALL SSHHOOCCKK,, FFIIRREE,, OORREEXXPPLLOOSSIIOONN HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnddaannggeerroouuss ooppeerraattiioonn,, pprrooppeerrttyy ddaammaaggee,, sseevveerreeppeerrssoonnaall iinnjjuurryy,, oorr ddeeaatthh..IImmpprrooppeerr sseerrvviicciinngg ccoouulldd rreessuulltt iinn ddaannggeerroouussooppeerraattiioonn,, pprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaalliinnjjuurryy,, oorr ddeeaatthh..

•• BBeeffoorree sseerrvviicciinngg,, ddiissccoonnnneecctt aallll eelleeccttrriiccaallppoowweerr ttoo ffuurrnnaaccee..

•• WWhheenn sseerrvviicciinngg ccoonnttrroollss,, llaabbeell aallll wwiirreess pprriioorrttoo ddiissccoonnnneeccttiioonn.. RReeccoonnnneecctt wwiirreess ccoorrrreeccttllyy..

•• VVeerriiffyy pprrooppeerr ooppeerraattiioonn aafftteerr sseerrvviicciinngg..

WWAARRNNIINNGGCCAARRBBOONN MMOONNOOXXIIDDEE PPOOIISSOONNIINNGGHHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..TToo eennssuurree ffuurrnnaaccee iiss vveenntteedd pprrooppeerrllyy,, ddoo nnoottrreeppllaaccee ffaaccttoorryy ssuupppplliieedd vveennttiinngg ccoommppoonneennttss wwiitthhffiieelldd ffaabbrriiccaatteedd ppaarrttss.. FFaabbrriiccaattiinngg ppaarrttss ccaann rreessuullttiinn ddaammaaggeedd vveennttss aanndd ccoommppoonneennttss aalllloowwiinnggccaarrbboonn mmoonnooxxiiddee ttoo eessccaappee tthhee vveennttiinngg ssyysstteemm..

WWAARRNNIINNGGCCAARRBBOONN MMOONNOOXXIIDDEE HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..WWhheenn rreeppllaacciinngg aa ffuurrnnaaccee,, eennssuurree tthhee vveennttiinnggssyysstteemm iiss aaddeeqquuaattee ffoorr tthhee nneeww ffuurrnnaaccee..

Page 3: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 3

WWAARRNNIINNGGFFIIRREE HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..DDoo nnoott iinnssttaallll tthhee ffuurrnnaaccee ddiirreeccttllyy oonn ccaarrppeettiinngg,, ttiilleeoorr ootthheerr ccoommbbuussttiibbllee mmaatteerriiaall ootthheerr tthhaann wwooooddfflloooorriinngg.. FFoorr vveerrttiiccaall ddoowwnnffllooww aapppplliiccaattiioonnss,,ssuubbbbaassee ((BBAAYYBBAASSEE220055)) mmuusstt bbee uusseedd bbeettwweeeenn tthheeffuurrnnaaccee aanndd ccoommbbuussttiibbllee fflloooorriinngg.. WWhheenn tthheeddoowwnnffllooww ffuurrnnaaccee iiss iinnssttaalllleedd vveerrttiiccaallllyy wwiitthh aaccaasseedd ccooiill,, aa ssuubbbbaassee iiss nnoott rreeqquuiirreedd..

WWAARRNNIINNGGWWAARRNNIINNGG!!TThhiiss pprroodduucctt ccaann eexxppoossee yyoouu ttoo cchheemmiiccaallssiinncclluuddiinngg lleeaadd,, wwhhiicchh aarree kknnoowwnn ttoo tthhee SSttaattee ooffCCaalliiffoorrnniiaa ttoo ccaauussee ccaanncceerr aanndd bbiirrtthh ddeeffeeccttss oorrootthheerr rreepprroodduuccttiivvee hhaarrmm..FFoorr mmoorree iinnffoorrmmaattiioonn ggoo ttoo wwwwww..PP6655WWaarrnniinnggss..ccaa..ggoovv..

WWAARRNNIINNGGEEXXPPLLOOSSIIOONN HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..PPrrooppaannee ggaass iiss hheeaavviieerr tthhaann aaiirr aanndd mmaayy ccoolllleecctt iinnaannyy llooww aarreeaass oorr ccoonnffiinneedd ssppaacceess.. IInn aaddddiittiioonn,,ooddoorraanntt ffaaddee mmaayy mmaakkee tthhee ggaass uunnddeetteeccttaabblleeeexxcceepptt wwiitthh aa wwaarrnniinngg ddeevviiccee.. IIff tthhee ggaass ffuurrnnaaccee iissiinnssttaalllleedd iinn aa bbaasseemmeenntt,, aann eexxccaavvaatteedd aarreeaass oorr aaccoonnffiinneedd ssppaaccee,, iitt iiss ssttrroonnggllyy rreeccoommmmeennddeedd ttooccoonnttaacctt aa ggaass ssuupppplliieerr ttoo iinnssttaallll aa ggaass ddeetteeccttiinnggwwaarrnniinngg ddeevviiccee iinn ccaassee ooff lleeaakk.. TThhee mmaannuuffaaccttuurreerrooff yyoouurr ffuurrnnaaccee ddooeess nnoott tteesstt aannyy ddeetteeccttoorrss aannddmmaakkeess nnoo rreepprreesseennttaattiioonnss rreeggaarrddiinngg aannyy bbrraanndd oorrttyyppee ooff ddeetteeccttoorr..

WWAARRNNIINNGGEELLEECCTTRRIICCAALL SSHHOOCCKK HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..DDoo nnoott bbyyppaassss tthhee ddoooorr sswwiittcchh oorr ppaanneell lloooopp bbyyaannyy ppeerrmmaanneenntt mmeeaannss..

WWAARRNNIINNGGEELLEECCTTRRIICCAALL SSHHOOCCKK HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..DDoo nnoott ttoouucchh aannyy ccoommppoonneennttss ootthheerr tthhaann tthhee MMeennuuaanndd OOppttiioonn bbuuttttoonnss oonn tthhee IIFFCC wwhheenn sseettttiinngg uupp tthheessyysstteemm oorr dduurriinngg ffaauulltt ccooddee rreeccoovveerryy..

WWAARRNNIINNGGFFIIRREE OORR EEXXPPLLOOSSIIOONN HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..DDoo NNOOTT aatttteemmpptt ttoo mmaannuuaallllyy lliigghhtt tthhee ffuurrnnaaccee..

WWAARRNNIINNGGCCAARRBBOONN MMOONNOOXXIIDDEE PPOOIISSOONNIINNGGHHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..FFoollllooww tthhee sseerrvviiccee aanndd//oorr ppeerriiooddiicc mmaaiinntteennaanncceeiinnssttrruuccttiioonnss ffoorr tthhee FFuurrnnaaccee aanndd vveennttiinngg ssyysstteemm..

WWAARRNNIINNGGCCAARRBBOONN MMOONNOOXXIIDDEE PPOOIISSOONNIINNGGHHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnsseerriioouuss ppeerrssoonnaall iinnjjuurryy oorr ddeeaatthh..MMaakkee ssuurree tthhaatt tthhee bblloowweerr ddoooorr iiss iinn ppllaaccee aanndd nnoottaajjaarr.. DDaannggeerroouuss ffuummeess ccoouulldd eessccaappee aanniimmpprrooppeerrllyy sseeccuurreedd ddoooorr..

WWAARRNNIINNGGEELLEECCTTRRIICCAALL SSHHOOCCKK HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..DDiissccoonnnneecctt ppoowweerr ttoo tthhee uunniitt bbeeffoorree rreemmoovviinngg tthheebblloowweerr ddoooorr.. AAllllooww aa mmiinniimmuumm ooff 1100 sseeccoonnddss ffoorrIIFFCC ppoowweerr ssuuppppllyy ttoo ddiisscchhaarrggee ttoo 00 vvoollttss..

WWAARRNNIINNGGSSAAFFEETTYY HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..TThheessee ffuurrnnaacceess aarree nnoott aapppprroovveedd oorr iinntteennddeedd ffoorriinnssttaallllaattiioonn iinn mmaannuuffaaccttuurreedd ((mmoobbiillee)) hhoouussiinngg,,ttrraaiilleerrss,, oorr rreeccrreeaattiioonnaall vveehhiicclleess..

SSAAFFEETTYY SSEECCTTIIOONN NNOONN--CCOONNDDEENNSSIINNGG FFUURRNNAACCEESS

Page 4: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

4 18-CE04D1-1B-EN

WWAARRNNIINNGGEEXXPPLLOOSSIIOONN HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..IInn tthhee eevveenntt tthhaatt eelleeccttrriiccaall,, ffuueell,, oorr mmeecchhaanniiccaallffaaiilluurreess ooccccuurr,, sshhuutt ggaass ssuuppppllyy ooffff aatt tthhee mmaannuuaallggaass vvaallvvee llooccaatteedd oonn tthhee ssuuppppllyy ggaass ppiippiinngg ccoommiinnggiinnttoo tthhee ffuurrnnaaccee bbeeffoorree ttuurrnniinngg ooffff tthhee eelleeccttrriiccaallppoowweerr ttoo tthhee ffuurrnnaaccee.. CCoonnttaacctt tthhee sseerrvviiccee aaggeennccyyddeessiiggnnaatteedd bbyy yyoouurr ddeeaalleerr..

WWAARRNNIINNGGEEXXPPLLOOSSIIOONN HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseerriioouuss ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..DDoo nnoott ssttoorree ccoommbbuussttiibbllee mmaatteerriiaallss,, ggaassoolliinnee,, oorrootthheerr ffllaammmmaabbllee vvaappoorrss oorr lliiqquuiiddss nneeaarr tthhee uunniitt..

WWAARRNNIINNGGSSAAFFEETTYY HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..DDoo nnoott uussee sseemmii--rriiggiidd mmeettaalllliicc ggaass ccoonnnneeccttoorrss((fflleexxiibbllee ggaass lliinneess)) wwiitthhiinn tthhee ffuurrnnaaccee ccaabbiinneett..

WWAARRNNIINNGGIINNSSTTAALLLLAATTIIOONN WWAARRNNIINNGG —— HHIIGGHHVVOOLLTTAAGGEE MMOOVVIINNGG PPAARRTTSS!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..BBooddiillyy iinnjjuurryy ccaann rreessuulltt ffrroomm hhiigghh vvoollttaaggeeeelleeccttrriiccaall ccoommppoonneennttss,, ffaasstt mmoovviinngg ffaannss,, aannddccoommbbuussttiibbllee ggaass.. FFoorr pprrootteeccttiioonn ffrroomm tthheesseeiinnhheerreenntt hhaazzaarrddss dduurriinngg iinnssttaallllaattiioonn aanndd sseerrvviicciinngg,,tthhee mmaaiinn ggaass vvaallvvee mmuusstt bbee ttuurrnneedd ooffff aanndd tthheeeelleeccttrriiccaall ssuuppppllyy mmuusstt bbee ddiissccoonnnneecctteedd.. IIffooppeerraattiinngg cchheecckkss mmuusstt bbee ppeerrffoorrmmeedd wwiitthh tthhee uunniittooppeerraattiinngg,, iitt iiss tthhee tteecchhnniicciiaann’’ss rreessppoonnssiibbiilliittyy ttoorreeccooggnniizzee tthheessee hhaazzaarrddss aanndd pprroocceeeedd ssaaffeellyy..

WWAARRNNIINNGGSSAAFFEETTYY HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..DDoo nnoott iinnssttaallll tthhee ffiilltteerr iinn tthhee rreettuurrnn dduucctt ddiirreeccttllyyaabboovvee tthhee ffuurrnnaaccee iinn hhoorriizzoonnttaall aapppplliiccaattiioonnss..IInnssttaallll tthhee ffiilltteerr rreemmootteellyy..

WWAARRNNIINNGGSSAAFFEETTYY HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..TTuurrnn tthhee ppoowweerr ttoo tthhee ffuurrnnaaccee ooffff bbeeffoorree sseerrvviicciinnggffiilltteerrss ttoo aavvooiidd ccoonnttaacctt wwiitthh mmoovviinngg ppaarrttss..

WWAARRNNIINNGGCCAARRBBOONN MMOONNOOXXIIDDEE HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..FFuurrnnaaccee vveennttiinngg iinnttoo aann uunnlliinneedd mmaassoonnrryy cchhiimmnneeyyoorr ccoonnccrreettee cchhiimmnneeyy iiss pprroohhiibbiitteedd..

WWAARRNNIINNGGCCAARRBBOONN MMOONNOOXXIIDDEE HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..TThhee cchhiimmnneeyy lliinneerr mmuusstt bbee tthhoorroouugghhllyy iinnssppeecctteeddttoo iinnssuurree nnoo ccrraacckkss oorr ootthheerr ppootteennttiiaall aarreeaass ffoorr fflluueeggaass lleeaakkss aarree pprreesseenntt iinn tthhee lliinneerr.. LLiinneerr lleeaakkss wwiillllrreessuulltt iinn eeaarrllyy ddeetteerriioorraattiioonn ooff tthhee cchhiimmnneeyy..

WWAARRNNIINNGGSSHHOOCCKK HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorrddeeaatthh..IIff aa ddiissccoonnnneecctt sswwiittcchh iiss pprreesseenntt,, iitt mmuusstt aallwwaayyss bbeelloocckkeedd iinn tthhee ooppeenn ppoossiittiioonn bbeeffoorree sseerrvviicciinngg tthheeuunniitt..

WWAARRNNIINNGGOOVVEERRHHEEAATTIINNGG AANNDD EEXXPPLLOOSSIIOONNHHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, ppeerrssoonnaall iinnjjuurryy oorr ddeeaatthh..SShhoouulldd oovveerrhheeaattiinngg ooccccuurr,, oorr tthhee ggaass ssuuppppllyy ffaaiill ttoosshhuutt ooffff,, sshhuutt ooffff tthhee ggaass vvaallvvee ttoo tthhee uunniitt bbeeffoorreesshhuuttttiinngg ooffff tthhee eelleeccttrriiccaall ssuuppppllyy..

CCAAUUTTIIOONNIIMMPPRROOPPEERR VVOOLLTTAAGGEE CCOONNNNEECCTTIIOONN!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee..DDoo NNOOTT ccoonnnneecctt tthhee ffuurrnnaaccee lliinnee vvoollttaaggee ttoo aa GGFFCCIIpprrootteecctteedd cciirrccuuiitt..

SSAAFFEETTYY SSEECCTTIIOONN NNOONN--CCOONNDDEENNSSIINNGG FFUURRNNAACCEESS

Page 5: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 5

CCAAUUTTIIOONNCCOORRRROOSSIIOONN WWAARRNNIINNGG!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaall iinnjjuurryy..DDoo nnoott iinnssttaallll tthhee ffuurrnnaaccee iinn aa ccoorrrroossiivvee oorrccoonnttaammiinnaatteedd aattmmoosspphheerree..

CCAAUUTTIIOONNSSHHAARRPP EEDDGGEE HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaall iinnjjuurryy..BBee ccaarreeffuull ooff sshhaarrpp eeddggeess oonn eeqquuiippmmeenntt oorr aannyyccuuttss mmaaddee oonn sshheeeett mmeettaall wwhhiillee iinnssttaalllliinngg oorrsseerrvviicciinngg..

CCAAUUTTIIOONNBBAACCKKUUPP WWRREENNCCHH RREEQQUUIIRREEDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaall iinnjjuurryy..UUssee aa bbaacckkuupp wwrreenncchh oonn tthhee ggaass vvaallvvee wwhheenniinnssttaalllliinngg ggaass ppiippiinngg ttoo pprreevveenntt ddaammaaggee ttoo tthhee ggaassvvaallvvee aanndd mmaanniiffoolldd aasssseemmbbllyy..

CCAAUUTTIIOONNFFRREEEEZZEE CCAAUUTTIIOONN!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaall iinnjjuurryy..IIff ccoommpplleettee ffuurrnnaaccee sshhuuttddoowwnn iiss ddoonnee dduurriinngg tthheeccoolldd wweeaatthheerr mmoonntthhss,, pprroovviissiioonnss mmuusstt bbee ttaakkeenn ttoopprreevveenntt ffrreeeezzee--uupp ooff aallll wwaatteerr ppiippeess aanndd wwaatteerrrreecceeppttaacclleess..

CCAAUUTTIIOONNFFRREEEEZZEE CCAAUUTTIIOONN!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaall iinnjjuurryy..WWhheenneevveerr yyoouurr hhoouussee iiss ttoo bbee vvaaccaanntt,, aarrrraannggee ttoohhaavvee ssoommeeoonnee iinnssppeecctt yyoouurr hhoouussee ffoorr pprrooppeerrtteemmppeerraattuurree.. TThhiiss iiss vveerryy iimmppoorrttaanntt dduurriinnggffrreeeezziinngg wweeaatthheerr.. IIff ffoorr aannyy rreeaassoonn yyoouurr ffuurrnnaacceesshhoouulldd ffaaiill ttoo ooppeerraattee ddaammaaggee ccoouulldd rreessuulltt,, ssuucchhaass ffrroozzeenn wwaatteerr ppiippeess..

CCAAUUTTIIOONNIIGGNNIITTIIOONN FFUUNNCCTTIIOONN!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn mmaayy rreessuulltt iinn ppoooorriiggnniittiioonn cchhaarraacctteerriissttiiccss..MMaaiinnttaaiinn mmaanniiffoolldd pprreessssuurree iinn hhiigghh aallttiittuuddeeiinnssttaallllaattiioonnss..

CCAAUUTTIIOONNWWAATTEERR DDAAMMAAGGEE!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaall iinnjjuurryy..IItt iiss rreeccoommmmeennddeedd tthhaatt aann eexxtteerrnnaall oovveerrffllooww ddrraaiinnppaann bbee iinnssttaalllleedd iinn aallll aapppplliiccaattiioonnss oovveerr aa ffiinniisshheeddcceeiilliinngg ttoo pprreevveenntt pprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaalliinnjjuurryy ffrroomm lleeaakkiinngg ccoonnddeennssaattee..

CCAAUUTTIIOONNHHOOTT SSUURRFFAACCEE!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnppeerrssoonnaall iinnjjuurryy..DDoo NNOOTT ttoouucchh iiggnniitteerr.. IItt iiss eexxttrreemmeellyy hhoott..

CCAAUUTTIIOONNFFUURRNNAACCEE SSEERRVVIICCEE CCAAUUTTIIOONN!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaall iinnjjuurryy..LLaabbeell aallll wwiirreess pprriioorr ttoo ddiissccoonnnneeccttiioonn wwhheennsseerrvviicciinngg ccoonnttrroollss.. VVeerriiffyy pprrooppeerr ooppeerraattiioonn aafftteerrsseerrvviicciinngg.. WWiirriinngg eerrrroorrss ccaann ccaauussee iimmpprrooppeerr aannddddaannggeerroouuss ooppeerraattiioonn..

CCAAUUTTIIOONNDDOO NNOOTT UUSSEE AASS CCOONNSSTTRRUUCCTTIIOONNHHEEAATTEERR!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaall iinnjjuurryy..IInn oorrddeerr ttoo pprreevveenntt sshhoorrtteenniinngg iittss sseerrvviiccee lliiffee,, tthheeFFuurrnnaaccee sshhoouulldd NNOOTT bbee uusseedd aass aa ““CCoonnssttrruuccttiioonnHHeeaatteerr”” dduurriinngg tthhee ffiinniisshhiinngg pphhaasseess ooffccoonnssttrruuccttiioonn uunnttiill tthhee rreeqquuiirreemmeennttss lliisstteedd iinn tthheeffuurrnnaaccee iinnssttaallllaattiioonn gguuiiddeelliinneess ooff tthhee IInnssttaalllleerr''ssGGuuiiddee hhaavvee bbeeeenn mmeett.. CCoonnddeennssaattee iinn tthhee pprreesseenncceeooff cchhlloorriiddeess aanndd fflluuoorriiddeess ffrroomm ppaaiinntt,, vvaarrnniisshh,,ssttaaiinnss,, aaddhheessiivveess,, cclleeaanniinngg ccoommppoouunnddss,, aannddcceemmeenntt ccrreeaattee aa ccoorrrroossiivvee ccoonnddiittiioonn wwhhiicchh mmaayyccaauussee rraappiidd ddeetteerriioorraattiioonn ooff tthhee hheeaatt eexxcchhaannggeerr..

CCAAUUTTIIOONNWWIIRRIINNGG IINNFFOORRMMAATTIIOONN!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaall iinnjjuurryy..TThhee iinntteeggrraatteedd ffuurrnnaaccee ccoonnttrrooll iiss ppoollaarriittyysseennssiittiivvee.. TThhee hhoott lleegg ooff tthhee 112200 VVAACC ppoowweerr mmuussttbbee ccoonnnneecctteedd ttoo tthhee BBLLAACCKK ffiieelldd lleeaadd..

SSAAFFEETTYY SSEECCTTIIOONN NNOONN--CCOONNDDEENNSSIINNGG FFUURRNNAACCEESS

Page 6: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

6 18-CE04D1-1B-EN

CCAAUUTTIIOONNEEQQUUIIPPMMEENNTT DDAAMMAAGGEE!!UUVV lliigghhtt eexxppoossuurree ccaann ccaauussee tthhee ppllaassttiicc bblloowweerrmmaatteerriiaall ttoo ddeetteerriioorraattee wwhhiicchh ccoouulldd lleeaadd ttoo BBlloowweerrHHoouussiinngg DDaammaaggee..FFoorr uunniittss ccoonnttaaiinniinngg aa ppllaassttiicc BBlloowweerr HHoouussiinngg,, DDooNNOOTT iinnssttaallll tthhiirrdd ppaarrttyy UUllttrraa--VViioolleett AAiirr CClleeaanneerrsswwhheerree tthhee BBlloowweerr HHoouussiinngg ccaann bbee eexxppoosseedd ttoo UUVVlliigghhtt..

For more information, visit www.IRCO.com or contact yourinstalling dealer.Ingersoll Rand800 Beaty St.Davidson, NC 28036

WWAARRNNIINNGGCCAARRBBOONN MMOONNOOXXIIDDEE PPOOIISSOONNIINNGGHHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhee sstteeppss oouuttlliinneedd bbeellooww ffoorr eeaacchhaapppplliiaannccee ccoonnnneecctteedd ttoo tthhee vveennttiinngg ssyysstteemm bbeeiinnggppllaacceedd iinnttoo ooppeerraattiioonn ccoouulldd rreessuulltt iinn ccaarrbboonnmmoonnooxxiiddee ppooiissoonniinngg oorr ddeeaatthh..

The following steps shall be followed foreach appliance connected to the ventingsystem being placed into operation, whileall other appliances connected to theventing system are not in operation:

•• IInnssppeecctt tthhee vveennttiinngg ssyysstteemm ffoorr pprrooppeerr ssiizzeeaanndd hhoorriizzoonnttaall ppiittcchh aass rreeqquuiirreedd iinn tthheeNNaattiioonnaall FFuueell GGaass CCooddee,, AANNSSII ZZ222233..11//NNFFPPAA5544 aanndd tthheessee iinnssttrruuccttiioonnss.. DDeetteerrmmiinnee tthheerree iissnnoo bblloocckkaaggee oorr rreessttrriiccttiioonn,, lleeaakkaaggee,, ccoorrrroossiioonnoorr ootthheerr ddeeffiicciieenncciieess wwhhiicchh ccoouulldd ccaauussee aannuunnssaaffee ccoonnddiittiioonn..

•• CClloossee aallll ddoooorrss aanndd wwiinnddoowwss bbeettwweeeenn tthheessppaaccee iinn wwhhiicchh tthhee aapppplliiaannccee((ss)) ccoonnnneecctteedd ttootthhee vveennttiinngg ssyysstteemm aarree llooccaatteedd.. AAllssoo cclloosseeffiirreeppllaaccee ddaammppeerrss..

•• TTuurrnn oonn ccllootthheess ddrryyeerrss aanndd aannyy aapppplliiaannccee nnoottccoonnnneecctteedd ttoo tthhee vveennttiinngg ssyysstteemm.. TTuurrnn oonnaannyy eexxhhaauusstt ffaannss ssuucchh aass rraannggee hhooooddss ssootthheeyy aarree ooppeerraattiinngg aatt mmaaxxiimmuumm ssppeeeedd.. DDoonnoott ooppeerraattee aa ssuummmmeerr eexxhhaauusstt ffaann..

•• FFoollllooww tthhee lliigghhttiinngg iinnssttrruuccttiioonnss.. PPllaaccee tthheeaapppplliiaannccee bbeeiinngg iinnssppeecctteedd iinnttoo ooppeerraattiioonn..AAddjjuusstt tthhee tthheerrmmoossttaatt ssoo aapppplliiaannccee iissooppeerraattiinngg ccoonnttiinnuuoouussllyy..

•• TTeesstt ffoorr ssppiillllaaggee ffrroomm ddrraafftt hhoooodd eeqquuiippppeeddaapppplliiaanncceess aatt tthhee ddrraafftt hhoooodd rreelliieeff ooppeenniinnggaafftteerr 55 mmiinnuutteess ooff mmaaiinn bbuurrnneerr ooppeerraattiioonn..UUssee tthhee ffllaammee ooff aa mmaattcchh oorr ccaannddllee..

•• IIff iimmpprrooppeerr vveennttiinngg iiss oobbsseerrvveedd dduurriinngg aannyy oofftthhee aabboovvee tteessttss,, tthhee vveennttiinngg ssyysstteemm mmuusstt bbeeccoorrrreecctteedd iinn aaccccoorrddaannccee wwiitthh tthhee NNaattiioonnaallFFuueell GGaass CCooddee,, AANNSSII ZZ222211..11//NNFFPPAA 5544..

•• AAfftteerr iitt hhaass bbeeeenn ddeetteerrmmiinneedd tthhaatt eeaacchhaapppplliiaannccee ccoonnnneecctteedd ttoo tthhee vveennttiinngg ssyysstteemmpprrooppeerrllyy vveennttss wwhheenn tteesstteedd,, rreettuurrnn aallll ddoooorrss,,wwiinnddoowwss,, eexxhhaauusstt ffaannss,, eettcc.. ttoo tthheeiirr pprreevviioouussccoonnddiittiioonn ooff uussee..

SSAAFFEETTYY SSEECCTTIIOONN NNOONN--CCOONNDDEENNSSIINNGG FFUURRNNAACCEESS

Page 7: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 7

Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Document Pack Contents . . . . . . . . . . . . . . . . . . 8

Furnace Installation Guidelines . . . . . . . . . . . . . 9Safety Practices and Precautions. . . . . . . . . . . 9

General Guidelines . . . . . . . . . . . . . . . . . . . . . . . 9

Locations and Clearances . . . . . . . . . . . . . . . . 10

Outline Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Furnace General Installation. . . . . . . . . . . . . . . 16S-Series Furnace Panel Removal . . . . . . . . . . 16

Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Combustion and Input Check. . . . . . . . . . 20Gas Valve Adjustment . . . . . . . . . . . . . . . . 21High Altitude Derate. . . . . . . . . . . . . . . . . . 22

General Venting . . . . . . . . . . . . . . . . . . . . . . . . . 23

Air for Combustion and Ventilation. . . . . . . . 25

Duct Connections. . . . . . . . . . . . . . . . . . . . . . . . 28

Return Air Filters . . . . . . . . . . . . . . . . . . . . . . . . 38

Electrical Connections . . . . . . . . . . . . . . . . . . . 40

Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . 40

Twinning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

General Start-up and Adjustment. . . . . . . . . . 45Preliminary Inspections . . . . . . . . . . . . . . . . . . 45

Lighting Instructions . . . . . . . . . . . . . . . . . . . . . 45

Control and Safety SwitchAdjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Furnace Combustion Air ExhaustOptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Combustion Air Conversions . . . . . . . . . . . . . 49

Integrated Furnace Control Menu. . . . . . . . . . 53

Setting Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

Integrated Furnace Control DisplayCodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Fault Code Recovery . . . . . . . . . . . . . . . . . . . . . 60

Sequence of Operation S8X1/S8X2 . . . . . . . . 61

Table of Contents

Page 8: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

8 18-CE04D1-1B-EN

AccessoriesTable 1. Accessories

Model Number Description Use with

BAYHANG Horizontal Hanging Kit All Furnaces

BAYLIFTB Dual Return Kit (B size extension) B Cabinet Furnaces

BAYLIFTC Dual Return Kit (C size extension) C Cabinet Furnaces

BAYLIFTD Dual Return Kit (D size extension) D Cabinet Furnaces

BAYBASE205 Downflow Subbase All Furnaces in Downflow orientation

BAYFLTR206 Filter Access Door Kit (Downflow only) All Furnaces in Downflow orientation

BAYSF1165AA (a) 1” SlimFit Box with MERV 4 Filter All Furnaces

BAYFLTR203 Horizontal Filter Kit B Cabinet Furnaces in Downflow/Horizontal

BAYFLTR204 Horizontal Filter Kit C Cabinet Furnaces in Downflow/Horizontal

BAYFLTR205 Horizontal Filter Kit D Cabinet Furnaces in Downflow/Horizontal

BAYVENT600A Internal venting kit B, C, and D Furnaces in Downflow orientation

BAYVENT800B Masonry Chimney Vent Kit All furnaces

BAYSWT13AHALTA High Altitude Pressure Switch Kit S8X1A026M2PSAA

BAYSWT14AHALTA High Altitude Pressure Switch Kit S8X1A040M3PSAA, S8X1B040M2PSAA,S8X1C080M5PSAA, S8X1C100M5PSAA

BAYSWT15AHALTA High Altitude Pressure Switch Kit S8X1B060M3PSAA, S8X1B060M4PSAA,S8X1B080M4PSAA

BAYSWT16AHALTA High Altitude Pressure Switch Kit S8X2A040M3PSAA. S8X2C080M5PSAA

BAYSWT17AHALTA High Altitude Pressure Switch Kit S8X2B060M3PSAA, S8X2B060M4PSAA

BAYSWT18AHALTA High Altitude Pressure Switch Kit S8X2B080M4PSAA

BAYSWT19AHALTA High Altitude Pressure Switch Kit S8X2C100M5PSAA

BAYLPSS400B Propane Conversion Kit with Stainless SteelBurners

All Furnaces except S8X1A026

BAYLPSS410A Propane Conversion Kit with Stainless SteelBurners

S8X1A026 Furnace only

PIP02095 U fitting for gas piping All Furnaces for right hand gas entry(a) Airflow greater than 1600 CFM requires dual returns

Document Pack ContentsItem Qty. Description

1

2 534

SSAAFFEETTYY WWAARRNNIINNGGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, andair-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or alteredequipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in theliterature and on the tags, stickers, and labels that are attached to the equipment.

May 2018 1188--CCEE0044DD11--11AA--EENN--EENN

Upflow/Downflow/HorizontalGas-Fired, Direct/Non-Direct Vent, 1–Stage and 2–Stage Induced Draft Furnaces with High EfficiencyMotorUUppffllooww,, DDoowwnnffllooww,,HHoorriizzoonnttaall RRiigghhtt//LLeeffttSingle StageS8X1A026M2PSAAS8X1A040M3PSAAS8X1B040M2PSAAS8X1B060M3PSAAS8X1B060M4PSAAS8X1B080M4PSAAS8X1C080M5PSAAS8X1C100M5PSAAS8X1D120M5PSAA

Two StageS8X2A040M3PSAAS8X2B060M3PSAAS8X2B060M4PSAAS8X2B080M4PSAAS8X2C080M5PSAAS8X2C100M5PSAAS8X2D120M5PSAA

NNoottee:: Graphics in this document are forrepresentation only. Actual model may

differ in appearance.

18-CE04D1-1A-EN

Installer’s Guide1 1 Plug — Gas

2 1 Installer’s Guide

3 1 Service Facts

4 1 Owner Guide

5 1 Limited Warranty

6 2 Tinnerman Clips

Note: Tinnerman Clips should bekept with unit and are usedif the door panel flange hole(s) becomes stripped.

Page 9: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 9

Furnace Installation GuidelinesThe following sections give general guidelines for theinstallation of the gas furnaces.

Safety Practices and PrecautionsThe following safety practices and precautions must befollowed during the installation, servicing, andoperation of this Furnace.

1. Use only with the type gas approved for thisFurnace. Refer to the Furnace rating plate.

2. Install the Furnace only in a location and position asspecified in “Locations and Clearances” of theseinstructions.

3. Provide adequate combustion and ventilation air tothe Furnace space as specified in “Air forCombustion and Ventilation” of these instructions.

4. Combustion products must be dischargedoutdoors. Connect this Furnace to an approved ventsystem only, as specified in the “Venting” sectionof these instructions.

5. Never test for gas leaks with an open flame. Use acommercially available soap solution madespecifically for the detection of leaks to check allconnections, as specified in the “Gas Piping”section of these instructions.

6. Always install the Furnace to operate within theFurnace’s intended temperature-rise range with aduct system which has an external static pressurewithin the allowable range, as specified on the unitrating plate. Airflow within temperature rise for cfmversus static is shown in the Service Factsaccompanying this Furnace.

7. When a Furnace is installed so that the supply ductscarry air circulated by the Furnace to areas outsidethe space containing the Furnace, the return airshall also be handled by a duct(s) sealed to theFurnace casing and terminating outside the spacecontaining the Furnace.

8. A gas-fired Furnace for installation in a residentialgarage must be installed as specified in "Locationand Clearances" section of these instructions.

9. The furnace may be used for temporary heating ofbuildings or structures under construction onlywhen the following conditions have been met:

a. The Furnace venting system must be completeand installed per manufacturer’s instructions.

b. The Furnace is controlled only by a roomComfort Control (no field jumpers).

c. The Furnace return air duct must be completeand sealed to the Furnace.

d. The Furnace input rate and temperature risemust be verified to be within the nameplatemarking.

e. A minimum 4” MERV 11 air filter must be inplace.

f. 100% of the Furnace combustion airrequirement must come from outside thestructure.

g. The Furnace return air temperature range isbetween 55 and 80 Fahrenheit.

h. Clean the Furnace, duct work, and componentsupon substantial completion of the constructionprocess, and verify Furnace operatingconditions including ignition, input rate,temperature rise, and venting, according to themanufacturer’s instructions.

10. IInn tthhee CCoommmmoonnwweeaalltthh ooff MMaassssaacchhuusseettttss,, tthhiisspprroodduucctt mmuusstt bbee ggaass ppiippeedd bbyy aa LLiicceennsseeddPPlluummbbeerr oorr GGaass FFiitttteerr..

This Furnace is certified to leak 1% or less of nominalair conditioning CFM delivered when pressurized to .5”water column with all inlets, outlets, and drains sealed.

General GuidelinesThe manufacturer assumes no responsibility forequipment installed in violation of any code orregulation.

It is recommended that Manual J of the AirConditioning Contractors Association (ACCA) or A.R.I.230 be followed in estimating heating requirements.When estimating heating requirements for installationat Altitudes above 2000 ft., remember the gas inputmust be reduced. See Combustion and Input Check.

MMaatteerriiaall iinn tthhiiss sshhiippmmeenntt hhaass bbeeeenn iinnssppeecctteedd aatt tthheeffaaccttoorryy aanndd rreelleeaasseedd ttoo tthhee ttrraannssppoorrttaattiioonn aaggeennccyywwiitthhoouutt kknnoowwnn ddaammaaggee.. IInnssppeecctt eexxtteerriioorr ooff ccaarrttoonnffoorr eevviiddeennccee ooff rroouugghh hhaannddlliinngg iinn sshhiippmmeenntt..UUnnppaacckk ccaarreeffuullllyy aafftteerr mmoovviinngg eeqquuiippmmeenntt ttooaapppprrooxxiimmaattee llooccaattiioonn.. IIff ddaammaaggee ttoo ccoonntteennttss iissffoouunndd,, rreeppoorrtt tthhee ddaammaaggee iimmmmeeddiiaatteellyy ttoo tthheeddeelliivveerriinngg aaggeennccyy..

Codes and local utility requirements governing theinstallation of gas fired equipment, wiring, plumbing,and flue connections must be adhered to. In theabsence of local codes, the installation must conformwith latest edition of the National Fuel Gas Code ANSIZ223.1 / NFPA 54. The latest code may be obtainedfrom the American Gas Association Laboratories, 400N. Capitol St. NW, Washington D.C. 20001.1-800-699-9277 or www.aga.org.

These furnaces have been classified as Fan AssistedCombustion system CATEGORY I furnaces as requiredby ANSI Z21.47 "latest edition". Therefore they do notrequire any special provisions for venting other thanwhat is indicated in these instructions.

Page 10: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

10 18-CE04D1-1B-EN

WWaarrnniinngg:: TThheessee ffuurrnnaacceess aarree nnoott aapppprroovveedd oorriinntteennddeedd ffoorr iinnssttaallllaattiioonn iinn mmaannuuffaaccttuurreedd ((mmoobbiillee))hhoouussiinngg,, ttrraaiilleerrss,, oorr rreeccrreeaattiioonnaall vveehhiicclleess..

Locations and ClearancesThe location of the Furnace is normally selected by thearchitect, the builder, or the installer. However, before

the Furnace is moved into place, be sure to considerthe following requirements:

1. Is the location selected as near the chimney or ventand as centralized for heat distribution as practical?

2. Do all clearances between the Furnace andenclosure equal or exceed the minimums stated inClearance Table below?

Minimum clearance to combustible materials

3. Is there sufficient space for servicing the Furnaceand other equipment? A minimum of 24 inchesfront accessibility to the Furnace must be provided.Any access door or panel must permit removal ofthe largest component.

4. Are there at least 3 inches of clearance between theFurnace combustion air openings in the front paneland any closed panel or door provided?

5. Are the ventilation and combustion air openingslarge enough and will they remain unobstructed? Ifoutside air is used, are the openings set 12" abovethe highest snow accumulation level?

6. Allow sufficient height in supply plenum above theFurnace to provide for cooling coil installation, ifthe cooling coil is not installed at the time of thisFurnace installation.

7. The Furnace shall be installed so electricalcomponents are protected from water.

8. If the Furnace is installed in a garage, it must beinstalled so that the burners, and the ignitionsource are located not less than 18 inches above thefloor and the Furnace must be located or protectedto avoid physical damage from vehicles.

9. The gas furnace must not be located whereexcessive exposure to contaminated combustionair will result in safety and performance relatedproblems. Avoid the following knowncontaminants:

a. Permanent wave solutions

b. Chlorinated waxes and cleaners

c. Chlorine based swimming pool chemicals

d. Water softening chemicals

e. De-icing salts or chemicals

f. Carbon tetrachloride

FFuurrnnaaccee IInnssttaallllaattiioonn GGuuiiddeelliinneess

Page 11: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 11

g. Halogen type refrigerants

h. Cleaning solvents (such asperchloroethylene)

i. Printing inks, paint removers, varnishes, etc.

j. Hydrochloric acid

k. Cements and glues

l. Antistatic fabric softeners for clothes dryers

m. Masonry acid washing materials

FFuurrnnaaccee IInnssttaallllaattiioonn GGuuiiddeelliinneess

Page 12: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

12 18-CE04D1-1B-EN

Outline Drawings

S8X2 shown

Table 2. 14.5” Width Cabinet

Page 13: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 13

Table 3. 17.5” Width Cabinet

OOuuttlliinnee DDrraawwiinnggss

Page 14: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

14 18-CE04D1-1B-EN

Table 4. 21.0” Width Cabinet

OOuuttlliinnee DDrraawwiinnggss

Page 15: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 15

Table 5. 24.5” Width Cabinet

OOuuttlliinnee DDrraawwiinnggss

Page 16: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

16 18-CE04D1-1B-EN

Furnace General InstallationThe following sections give general instructions for theinstallation of the gas furnaces.

S-Series Furnace Panel Removal

Note: For the S8X2 furnace, a 5/16” Allen wrench is required toremove the four latches on the front panel.

Note: For the S8X1 furnace, a 1/4" nut driver is required to removethe two screws at the top of the front panel. The front panel canthen be removed by lifting upwards.

Note: Tinnerman clips are provided in the doc pack if the door panelflange hole(s) becomes stripped.

Tinnerman clip locations(if needed)

Page 17: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 17

Gas Piping

Important: The furnace default is left side gas piping.

Note: For ease of installation, optional accessory part PIP02095 isrecommended for gas piping entering the right side of thefurnace.

Furnace in upflow orientation with gas piping on leftAutomatic Gas Valvewith Manual Shut-o!

Main ManualShut-o! Valve

GroundUnionJoint

Drip Leg

1/8” NPTTest Fitting

Furnace in upflow orientation with gas piping on right

Note: For ease of installation, optional accessory part PIP02095 isrecommended for gas piping entering the right side of thefurnace in the upflow orientation.

Automatic Gas Valvewith Manual Shut-o!

Main ManualShut-o! Valve

GroundUnionJoint

Drip Leg

1/8” NPTTest Fitting

Furnace in downflow orientation with gas piping on left

Note: For ease of installation, optional accessory part PIP02095 isrecommended for gas piping entering the left side of thefurnace in the downflow orientation.

Automatic Gas Valvewith Manual Shut-o!

Main ManualShut-o! Valve

1/8” NPTTest Fitting

GroundUnionJoint

Drip Leg

Furnace in downflow orientation with gas piping on right

Automatic Gas Valvewith Manual Shut-o!

Main ManualShut-o! Valve

GroundUnionJoint

Drip Leg

1/8” NPTTest Fitting

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 18: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18 18-CE04D1-1B-EN

Note: For ease of installation, optional accessory part PIP02095 isrecommended for gas piping entering the right side of thefurnace.

Furnace in horizontal left orientation with gas piping out top

Note: For ease of installation, optional accessory part PIP02095 isrecommended for gas piping entering the top of the furnace inthe horizontal left position.

Automatic Gas Valvewith Manual Shut-o!

Main ManualShut-o! Valve

GroundUnionJoint

Drip Leg

1/8” NPTTest Fitting

Furnace in horizontal left orientation with gas piping out bottom

Automatic Gas Valvewith Manual Shut-o!

Main ManualShut-o! Valve

GroundUnionJoint

Drip Leg

1/8” NPTTest Fitting

Furnace in horizontal right orientation with gas piping out top

Automatic Gas Valve with Manual Shut-o!

Main ManualShut-o! Valve

GroundUnionJoint

Drip Leg

1/8” NPTTest Fitting

Furnace in horizontal right orientation with gas piping out bottom

Note: For ease of installation, optional accessory part PIP02095 isrecommended for gas piping entering the bottom of thefurnace in the horizontal right position.

Automatic Gas Valvewith Manual Shut-o�

Main ManualShut-o� Valve

GroundUnionJoint

Drip Leg 1/8” NPTTest Fitting

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 19: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 19

The furnace is shipped standard for left side installation of gas piping.A cutout with plug is provided on the right side for an alternate gaspiping arrangement.

The installation of piping shall be in accordance with piping codes andthe regulations of the local gas company. Pipe joint compound must beresistant to the chemical reaction with liquefied petroleum gases.

Important: If local codes allow the use of flexible gas applianceconnector, always use a new listed connector. Do not usea connector which has previously serviced another gasappliance.

Refer to the piping table for delivery sizes. Connect gas supply to theunit, using a ground joint union and a manual shut-off valve. Nationalcodes require a condensation drip leg to be installed ahead of the gasvalve.

The furnace and its individual shut-off valve must be disconnectedfrom the gas supply piping system during any pressure testing of thatsystem at test pressures in excess of 1/2 psig (3.5 kPa).

The furnace must be isolated from the gas supply piping by closing itsindividual manual shut-off valve during any pressure testing of thegas supply piping system at test pressures equal to or less than 1/2psig (3.5 kPa).

Note: Maximum pressure to the gas valve for natural gas is 13.8" W.C. Minimum pressure is 5.0" W.C. Maximum pressure to thegas valve for propane is 13.8" W.C. Minimum pressure is 11.0"W.C.

NATURAL GAS ONLY

TABLE OF CUBIC FEET PER HOUR OF GASFOR VARIOUS PIPE SIZES AND LENGTHS

PIPESIZE

LENGTH OF PIPE

10 20 30 40 50 60 70

1/2 131 90 72 62 55 50 46

3/4 273 188 151 129 114 104 95

1 514 353 284 243 215 195 179

1–1/4 1060 726 583 499 442 400 368

This table is based on Pressure Drop of 0.3 inch W.C. and 0.6 SP.GR. Gas

All gas fittings must be checked for leaks using a soapy solution beforelighting the furnace.DONOT CHECKWITH ANOPEN FLAME!

For propane conversions, the S8X1A026 will require LP kitBAYLPSS410A conversion kit with stainless steel burners. For propaneconversions on all other S-Series Furnaces, use BAYLPSS400Bconversion kit with stainless steel burners.

ORIFICE SIZES

INPUTRATINGBTUH

NUMBER OFBURNERS

MAIN BURNER ORIFICEDRILL SIZE

NAT. GAS PROPANEGAS

26,000 2 51 59

40,000 2 45 56

60,000 3 45 56

80,000 4 45 56

100,000 5 45 56

120,000 6 45 56

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 20: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

20 18-CE04D1-1B-EN

Combustion and Input Check

1. Make sure all gas appliances are off except the furnace.

2. Clock the gas meter with the furnace operating (determine thedial rating of the meter) for one revolution.

3. Match the "Sec" column in the gas flow table with the timeclocked.

4. Read the "Flow" column opposite the number of seconds clocked.

5. Use the following factors if necessary:

a. For 1 Cu. Ft. Dial Gas Flow CFH = Chart Flow Reading ÷ 2

b. For 1/2 Cu Ft. Dial Gas Flow CFH = Chart Flow Reading ÷ 4

c. For 5 Cu. Ft. Dial Gas Flow CFH = 10X Chart Flow Reading ÷ 4

6. Multiply the final figure by the heating value of the gas obtainedfrom the utility company and compare to the nameplate rating.This must not exceed the nameplate rating.

Gas Flow in Cubic Feet Per Hour

2 Cubic Foot Dial

Sec. Flow Sec. Flow Sec. Flow Sec. Flow

10 732 31 236 52 141 86 85

11 666 32 229 53 138 88 83

12 610 33 222 54 136 90 81

13 563 34 215 55 133 94 78

14 523 35 209 56 131 98 75

15 488 36 203 57 128 100 73

16 458 37 198 58 126 104 70

17 431 38 193 59 124 108 68

18 407 39 188 60 122 112 65

19 385 40 183 62 118 116 63

20 366 41 179 64 114 120 61

21 349 42 174 66 111 130 56

22 333 43 170 68 108 140 52

23 318 44 166 70 105 150 49

24 305 45 163 72 102 160 46

25 293 46 159 74 99 170 43

26 282 47 156 76 96 180 41

27 271 48 153 78 94 190 39

28 262 49 149 80 92 200 37

29 253 50 146 82 89

30 244 51 144 84 87

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 21: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 21

Gas Valve Adjustment

Changes can be made by adjusting the manifold pressure, or changingorifices (orifice change may not always be required). To adjust themanifold pressure:

1. Turn off all electrical power to the system.

2. Attach a manifold pressure gauge with flexible tubing to the outletpressure boss marked "OUT P" on White- Rodgers gas valvemodel 36J.

3. Loosen (Do Not remove) the pressure tap test set screw one turnwith 3/32" hex wrench.

a. The pressure tap adjustment kit (KIT07611) contains a 3/32"hex wrench, a 5/16" hose and a connector and can beordered through Global Parts.

4. Turn on system power and make a call for 2nd stage heating.Insure that the unit is in second stage heating by verifying 24 VACis measured between C and HI on the gas valve.

Important: Adjust 2nd stage on the gas valve before attempting toadjust 1st stage.

5. Adjust 2nd stage gas heat by removing the high (HI) adjustmentregulator cover screw.

a. To increase outlet pressure, turn the regulator adjust screwclockwise.

b. To decrease outlet pressure, turn the regulator adjust screwcounterclockwise.

c. Adjust regulator until pressure shown on manometermatches the pressure specified in the table.

The input of no more than nameplate rating and no less than93% of the nameplate rating, unless the unit is derated forhigh altitude.

d. Replace and tighten the regulator cover screw securely.

e. Remove call for second stage heat, first stage heat is nowrunning.

6. Adjust 1st stage gas heat by removing the low (LO) adjustmentregulator cover screw.

a. To increase outlet pressure, turn the regulator adjust screwclockwise.

b. To decrease outlet pressure, turn the regulator adjust screwcounterclockwise.

c. Adjust regulator until pressure shown on manometermatches the pressure specified in the table.

The input of no more than nameplate rating and no less than93% of the nameplate rating, unless the unit is derated forhigh altitude.

d. Replace and tighten the regulator cover screw securely.

7. Cycle the valve several times to verify regulator setting.

a. Repeat steps 5-7 if needed.

8. Turn off all electrical power to the system.

9. Remove the manometer and flexible tubing and tighten thepressure tap screw.

10. Using a leak detection solution or soap suds, check for leaks at thepressure outlet boss and pressure tap test screw.

11. Turn on system power and check operation of the unit.

Outlet Pressure Boss

2nd Stage (HI) Manifold Pressure Adjustment

1st Stage (LO) Manifold Pressure Adjustment

Inlet PressureBoss

Gas Valve On/OffToggle Switch

White-Rodgers 36J

Outlet Pressure Boss

1st Stage (LO) Manifold Pressure Adjustment

Inlet PressureBoss

Gas Valve On/OffToggle Switch

White-Rodgers 36J

Maximum and Minimum INLET Pressure (inches w.c.)

Natural Gas Propane

Maximum 13.8 13.8

Minimum 5 11

Maximum and Minimum Fuel Manifold Pressure Settings (inches w.c.) 2nd Stg/1st Stg

All models except S8X1D120,S8X2D120

3.5/1.6 10/6

S8X1D120, S8X2D120 3.5/1.8 10/7.5

Orifice sizes for Natural Gas and Propane

All models except S8X1A026 45 56

S8X1A026 51 59

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 22: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

22 18-CE04D1-1B-EN

High Altitude Derate

Input ratings (BTUH) of these Furnaces are based on sea leveloperation and should not be changed at elevations up to 2,000 ft. (610m).

If the installation is 2,000 ft. (610 m) or above, the Furnace input rate(BTUH) shall be reduced 4% for each 1,000 ft. above sea level.

Installations of this furnace at altitudes above 2,000 ft. (610 m) shallbe made utilizing the Part Numbers for Replacement Orifices table inthese installation instructions.The Furnace input rate shall be checked by clocking the gas flow rate(CFH) and multiplying by the heating value obtained from the localutility supplier for the gas being delivered at the installed altitude.Input rate changes can be made by adjusting the Manifold Pressure(min 3.0 - max 3.7 in. W.C. - Natural Gas) or changing orifices (orificechange may not always be required).

If the desired input rate can not be achieved with a change in ManifoldPressure, then the orifices must be changed. Propane installations willrequire an orifice change.

See the table for help in selecting orifices if orifice change is required.Furnace input rate and temperature rise should be checked again afterchanging orifices to confirm the proper rate for the altitude.

PART NUMBERS FOR REPLACEMENT ORIFICES

DRILL SIZE PARTNUMBER

DRILL SIZE PARTNUMBER

44 ORF00501 54 ORF00555

45 ORF00644 55 ORF00693

46 ORF00909 56 ORF00907

47 ORF00910 57 ORF00908

48 ORF01099 58 ORF01338

49 ORF00503 59 ORF01339

50 ORF00493

Turn the main Gas Valve toggle switch within the unit to the "OFF"position. Turn the external gas valve to "ON". Purge the air from thegas lines. After purging, check all gas connections for leaks with asoapy solution – DONOT CHECKWITH ANOPEN FLAME. Allow 5minutes for any gas that might have escaped to dissipate.

Propane Gas being heavier than air may require forced ventilation.Turn the toggle switch on the Gas Valve in the unit to the "ON"position.

Note: For furnaces requiring modifications other than only gas orificeand/or manifold pressure adjustment for installation at highaltitude, installation of this furnace at altitudes above 200 ft(610 m) shall be made in accordance with the listed HighAltitude Conversion Kit available with this furnace.

The table lists the main burner orificesused with the furnace. If a change oforifices is required to correct the furnaceinput rating refer to the part number forreplacement orifices table.

Installation of this furnace at altitudesabove 2000 ft (610m) shall be inaccordance with local codes, or in theabsence of local codes, the National FuelGas Code, ANSI Z223.1/NFPA 54.

OrificeTwist DrillSize If

Installed atSea Level

Altitude Above Sea Leveland Orifice Required at Other Elevations

2000 3000 4000 5000 6000 7000 8000 9000 10000

42 42 43 43 43 44 44 45 46 47

43 44 44 44 45 45 46 47 47 48

44 45 45 45 46 47 47 48 48 50

45 46 47 47 47 48 48 49 49 50

46 47 47 47 48 48 49 49 50 51

47 48 48 49 49 49 50 50 51 52

54 54 55 55 55 55 55 56 56 56

55 55 55 55 56 56 56 56 56 57

56 56 56 57 57 57 58 59 59 60

57 58 59 59 60 60 61 62 63 63

58 59 60 60 61 62 62 63 63 64

From National Fuel Gas Code —Table E.1.1(d)

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 23: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 23

General VentingVENT PIPING

These furnaces have been classified as Fan-AssistedCombustion System, Category I furnaces under the"latest edition" provisions of ANSI Z21.47 standards.Category I furnaces operate with a non-positive ventstatic pressure and with a flue loss of not less than 17percent.

Multistory and common venting are permitted forthese furnaces. Venting systems shall be in accordance

with the National Fuel Gas Code, ANSI Z223.1/NFPA 54,local codes, and this installation manual.

If desired, a side wall termination can be accomplishedthrough the use of a listed "add-on" draft inducer. Theinducer must be installed according to the inducermanufacturer’s instructions. Set the barometricpressure relief to achieve –0.02 inch water column.

The furnace shall be connected to a factory builtchimney or vent complying with a recognized standard,or a masonry or concrete chimney lined with a liningmaterial acceptable to the authority having jurisdiction.

VENTING INTO AMASONRY CHIMNEYIf the chimney is oversized, the liner is inadequate, or flue-gascondensation is a problem in your area, consider using the chimney asa pathway or chase for type "B" vent or flexible vent liner. If flexibleliner material is used, size the vent using the "B" vent tables, thenreduce the maximum capacity by 20% (multiply 0.80 times themaximum capacity). Masonry Chimney Kit BAYVENT800B may beused with these furnaces (Upflowmodel furnaces only) to allowventing into a masonry chimney. Refer to the BAYVENT800BInstaller’s Guide for application requirements.INTERNAL MASONRY CHIMNEYSVenting of fan assisted appliances into a lined, internal masonrychimney is allowed only if it is common vented with at least onenatural draft appliance;OR, if the chimney is lined with type "B",double wall vent or suitable flexible liner material

WWAARRNNIINNGGSSaaffeettyy HHaazzaarrdd!!FFaaiilluurree ttoo ffoollllooww tthhiiss wwaarrnniinngg ccoouulldd rreessuulltt iinn ccaarrbboonnmmoonnooxxiiddee ppooiissoonniinngg oorr ddeeaatthh..TThhee cchhiimmnneeyy lliinneerr mmuusstt bbee tthhoorroouugghhllyy iinnssppeecctteedd ttooiinnssuurree nnoo ccrraacckkss oorr ootthheerr ppootteennttiiaall aarreeaass ffoorr fflluuee ggaasslleeaakkss aarree pprreesseenntt iinn tthhee lliinneerr.. LLiinneerr lleeaakkss wwiillll rreessuullttiinn eeaarrllyy ddeetteerriioorraattiioonn ooff tthhee cchhiimmnneeyy..

The following section does not apply if BAYVENT800B (Masonry Chimney Vent Kit) is used. All instructions with the kit must befollowed.

Masonry Chimney Venting

Type Furnace Tile Lined Chimney Chimney Lining

Internal External “B” Vent Flexible Metal Liner

Single Fan Assist No No Yes Yes (a)

Fan Assist + Fan Assist No No Yes Yes (a)

Fan Assist + Natural Yes No Yes Yes (a)

(a) Flexible chimney liner size is determined by using the type "B" vent size for the available BTUH input, then reducing the maximum capacity by 20%(multiply maximum capacity times 0.80). The minimum capacity is the same as shown in the "B" vent tables.

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 24: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

24 18-CE04D1-1B-EN

EXTERNAL MASONRY CHIMNEYVenting of fan assisted appliances into external chimneys (one or more wallsexposed to outdoor temperatures), requires the chimney be lined with type "B",double wall vent or suitable flexible chimney liner material. This applies in allcombinations of common venting as well as for fan assisted appliances ventedalone.The following installation practices are recommended to minimize corrosion causedby condensation of flue products in the furnace and flue gas system.

1. Avoid an excessive number of bends.

2. Horizontal runs should pitch upward at least 1/4" per foot.

3. Horizontal runs should be as short as possible.

4. All vent pipe or connectors should be securely supported and must be insertedinto, but not beyond the inside wall at the chimney vent.

5. When vent connections must pass through walls or partitions of combustiblematerial, a thimble must be used and installed according to local codes.

6. Vent pipe through the roof should be extended to a height determined byNational Fuel Gas Code or local codes. It should be capped properly to preventrain water from entering the vent. Roof exit should be waterproofed.

7. Use type "B" double wall vent when vent pipe is routed through cool spaces(below 60° F.).

8. Where long periods of airflow are desired for comfort, use long fan cyclesinstead of continuous airflow.

9. Apply other good venting practices as stated in the venting section of theNational Fuel Gas Code ANSI Z223.1 "latest edition".

10. Vent connectors serving appliance vented by natural draft or non-positive pressure shall not be connected into any portion of amechanized draft system operating under positive pressure.

11. Horizontal pipe runs must be supported by hangers, straps or other suitablematerial in intervals at a minimum of every 3 feet of pipe.

12. A furnace shall not be connected to a chimney or flue serving a separateappliance designed to burn solid fuel.

13. The flow area of the largest section of vertical vent or chimney shall not exceed7 times the smallest listed appliance categorized vent area, flue collar area, ordraft hood outlet area unless designed in accordance with approvedengineering methods.

Maximum Vent or Tile Lined Chimney Flow Area = [ππ(D*)2 ]/4 X 7* Drafthood outlet diameter, flue collar diameter, or listed appliance categorizedvent diameter.

Gas Vent Termination

Roof Pitch Minimum Height

Flat to 6/12Over 6/12 to 7/12Over 7/12 to 8/12Over 8/12 to 9/12Over 9/12 to 10/12Over 10/12 to 11/12Over 11/12 to 12/12Over 12/12 to 14/12Over 14/12 to 16/12Over 16/12 to 18/12Over 18/12 to 20/12Over 20/12 to 22/12

1.0 Feet (a)1.25 Feet1.5 Feet2.0 Feet2.5 Feet3.25 Feet4.0 Feet5.0 Feet6.0 Feet7.0 Feet7.5 Feet8.0 Feet

(a) This requirement covers most installations

Vertical Wall

Lowest DischargeOpening

8” Min.

ListedCap

MinimumHeight

Roof Pitch is X/12

The vent termination should not beless than 8 ft. from a vertical wall.

(a) This requirement covers most installations

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 25: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 25

Air for Combustion and VentilationAdequate flow of combustion and ventilating air must not beobstructed from reaching the Furnace. Air openings provided in theFurnace casing must be kept free of obstructions which restrict theflow of air. Airflow restrictions affect the efficiency and safe operationof the Furnace. Keep this in mind should you choose to remodel orchange the area which contains your Furnace. Furnaces must have afree flow of air for proper performance.

Provisions for combustion and ventilation air shall be made inaccordance with "latest edition" of Section 9.3, Air for Combustion andVentilation, of the National Fuel Gas Code, ANSI Z223.1 / NFPA 54.Installation Codes, and applicable provisions of the local buildingcodes. Special conditions created by mechanical exhausting of air andfireplaces must be considered to avoid unsatisfactory Furnaceoperation.

Furnace location may be in an unconfined space or a confinedspace.

Unconfined space are installations with 50 cu. ft. or more per 1000BTU/hr input from all equipment installed. Unconfined spaces aredefined in the table and illustration for various furnace sizes. Thesespaces may have adequate air by infiltration to provide air forcombustion, ventilation, and dilution of flue gases. Buildings with tightconstruction (for example, weather stripping, heavily insulated,caulked, vapor barrier, etc.), may need additional air provided asdescribed for confined space.

Minimum Area in Square Feet for Unconfined Space Installations

Furnace Maximum BTUH InputRating

With 8 Ft. Ceiling,Minimum Area in Square Feet of

Unconfined Space

26,00040,00060,00080,000100,000120,000

165250375500625750

NODOORS

FURNACEWATERHEATER

CLOTHESDRYER

UNCONFINED

50 CU. FT. OR MOREPER 1000 BTU/HR INPUTALL EQUIP. INSTALLED

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 26: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

26 18-CE04D1-1B-EN

Confined spaces are installations with less than 50 cu. ft. of space per1000 BTU/ hr input from all equipment installed. Confined spaces aredefined in the table and illustration for various furnace sizes. Air forcombustion and ventilation requirements can be supplied from insidethe building.

1. The following types of installations will require use of OUTDOORAIR for combustion, due to chemical exposures:

* Commercial buildings

* Buildings with indoor pools

* Furnaces installed in commercial laundry rooms

* Furnaces installed in hobby or craft rooms

* Furnaces installed near chemical storage areas

Exposure to the following substances in the combustion air supply willalso require OUTDOOR AIR for combustion:

* Permanent wave solutions

* Chlorinated waxes and cleaners

* Chlorine based swimming pool chemicals

* Water softening chemicals

* Deicing salts or chemicals

* Carbon Tetrachloride

* Halogen type refrigerants

* Cleaning solvents (such as perchloroethylene)

* Printing inks, paint removers, varnish, etc.

* Hydrochloric acid

* Cements and glues

* Antistatic fabric softeners for clothes dryers

* Masonry acid washing material

Note: Extended warranties are not available in some instances.Extended warranty does not cover repairs to equipmentinstalled in establishments with corrosive atmospheres,including but not limited to, dry cleaners, beauty shops, andprinting facilities.

Minimum Free Area in Square Inches Each Opening (Furnace Only)in a Confined Space

Furnace MaxBTUH.Input

Rtg.

Air FromInside

Air From Outside

Vertical Duct(a)

HorizontalDuct (b)

26,00040,00060,00080,000100,000120,000

100100100100100120

71015202530

142030405060

(a) 1 Square inch per 4000 BTU/hr Vertical Duct.(b) 1 Square inch per 2000 BTU/hr Horizontal Duct.

FURNACE

CONFINED

LESS THAN 50 CU. FT. PER 1000 BTU/HR INPUTALL EQUIP. INSTALLED

All air from inside the building The confined space shall be providedwith two permanent openings communicating directly with anadditional room(s) of sufficient volume so that the combined volumeof all spaces meets the criteria for an unconfined space. The totalinput of all gas utilization equipment installed in the combined spaceshall be considered in making this determination. Refer to theMinimum Free Area in square inches for confined spaces table, forminimum open areas required.

CONFINED SPACEAIR FROM INSIDE BUILDING

CONFINED SPACE

PERMANENTOPENINGS

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 27: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 27

All air from outdoors The confined space shall be provided with twopermanent openings, one commencing within 12 inches of the top andone commencing within 12 inches of the bottom of the enclosure.The openings shall communicate directly, or by ducts, with theoutdoors or spaces (crawl or attic) that freely communicate with theoutdoors. Refer to the Minimum Free Area in square inches forconfined spaces table, for minimum open areas required.

CONFINED SPACEAIR FROM OUTDOORS

CONFINED SPACE

OUTLET

OUTDOOR AIR DUCTS

INLET

CONFINED SPACEAIR FROM VENTILATED ATTIC/CRAWL SPACE

CONFINED SPACE

ALTERNATEINLET AIR

INLETAIR DUCT

OUTLETAIR

ATTIC LOUVERSTO OUTDOORS

CONFINED SPACEAIR FROM VENTILATED ATTIC

CONFINED SPACE

INLETAIR DUCT

OUTLETAIR

ATTIC LOUVERSTO OUTDOORS

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 28: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

28 18-CE04D1-1B-EN

Duct ConnectionsAir duct systems should be installed in accordance with standards forair conditioning systems, National Fire Protection AssociationPamphlet No. 90. They should be sized in accordance with ACCAManual D or whichever is applicable. Check on controls to makecertain they are correct for the electrical supply.Central furnaces, when used in connection with cooling units, shall beinstalled in parallel or on the upstream side of the cooling units toavoid condensation in the heating element, unless the furnace hasbeen specifically approved for downstream installation. With a parallelflow arrangement, the dampers or other means used to control flow ofair shall be adequate to prevent chilled air from entering the furnace,and if manually operated, must be equipped with means to preventoperation of either unit unless the damper is in full heat or coolposition.Flexible connections of nonflammable material may be used for returnair and discharge connections to reduce the transmission of vibration.Though these units have been specifically designed for quiet, vibrationfree operation, air ducts can act as sounding boards and could, ifpoorly installed, amplify the slightest vibration to the annoyance level.

When the furnace is located in a utility room adjacent to the livingarea, the system should be carefully designed with returns whichminimize noise transmission through the return air grille. Althoughthese winter air conditioners are designed with large blowersoperating at moderate speeds, any blower moving a high volume ofair will produce audible noise which could be objectionable when theunit is located very close to a living area. It is often advisable to routethe return air ducts under the floor or through the attic. Such designpermits the installation of air return remote from the living area (i.e.central hall).When the furnace is installed so that the supply ducts carry aircirculated by the furnace to areas outside the space containing thefurnace, the return air shall also be handled by a duct(s) sealed to thefurnace and terminating outside the space containing the furnace.For furnaces not equipped with a cooling coil, it is recommended thatthe outlet duct be provided with a removable access panel. Theopening shall be accessible when the furnace is installed and shall beof such a size that the heat exchanger can be viewed for possibleopenings using light assistance or a probe can be inserted forsampling the air stream. The removable cover must be sealed toprevent air leaks.

Where there is no complete return duct system, the returnconnectionmust be run full size from the Furnace to a locationoutside the utility room, basement, attic, or crawl space.Do Not install return air through the back of the Furnace cabinet.Do Not install return air through the side of the furnace cabinet onhorizontal applications without following the guidelines in the ReturnAir Filters section in the figure for Horizontal furnace with side return.

Carbon monoxide, fire or smoke can cause serious bodily injury,death, and/or property damage.A variety of potential sources of carbon monoxide can be found in abuilding or dwelling such as gas-fired clothes dryers, gas cookingstoves, water heaters, furnaces and fireplaces. The U.S. ConsumerProduct Safety Commission recommends that users of gas-burningappliances install carbon monoxide detectors as well as fire andsmoke detectors per the manufactures installation instructions to helpalert dwelling occupants of the presence of fire, smoke or unsafelevels of carbon monoxide. These devices should be listed byUnderwriters Laboratories, Inc. Standards for Single and MultipleStation Carbon Monoxide Alarms, UL 2034.

Note: The manufacturer of your Furnace DOES NOT test anydetectors and makes no representations regarding any brandor type of detector.

Note: Seal per local codes

In horizontal applications, the furnace must be supported with one ofthe following methods.

1. Support below with non-combustible material as shown in theillustration.

2. Use BAYHANG kit. See kit instructions.

3. Use unistrut with cabling to provide support from under the unit.

4. Use strapping material in locations shown in illustration.

WHEN SUSPENDING THE HORIZONTAL FURNACE, IT SHOULD BE SUSPENDEDBY ATTACHING TO THE CABINETIN THE PLACES SHOWN.

WHEN SUPPORTING THEFURNACE FROM BELOW, SUPPORT FRONT TO BACK (AS SHOWN) OR SIDE TO SIDE.

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 29: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 29

Table 6. Supply Duct Connections

Upflow Furnace with Coil

1. Bend furnace flanges up.

2. Set the coil on top of the furnace.

3. Screw through the coil cabinet into the furnace flange. Guideholes are located on the coil.

Note: There are no longer guide holes located on the furnace flange.

4. Seal per local codes and requirements.

Furnace in Horizontal Left with Coil

1. Bend furnace flanges up.

2. Support the furnace and coil independently.

3. Screw through the coil cabinet into the furnace flange. Guideholes are located on the coil.

Note: There are no longer guide holes located on the furnace flange.

4. Seal per local codes and requirements.

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 30: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

30 18-CE04D1-1B-EN

Furnace in Horizontal Right with “A” Coil

1. Bend furnace flanges down.

2. Support the furnace and coil independently.

3. Match the coil up flush to the back of the furnace.

4. Seal per local codes and requirements.

Note: Flat or dedicated horizontal coils may require flanges to be bentupward.

Downflow Furnace with Coil

1. Bend furnace flanges down.

2. Set the furnace on top of the coil so that it is flush with the back ofthe furnace.

3. Seal per local codes and requirements.

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 31: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 31

Horizontal Right and Downflow Furnace — no Coil

Important: A BAYBASE is required when installing the furnace on acombustible floor.

1. Bend furnace flanges up.

2. Attach ducting.

3. Seal per local codes and requirements.

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 32: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

32 18-CE04D1-1B-EN

Table 7. Return Duct Connections

Return Ducting General Guidelines

• Back returns are not allowed on any S-Series Furnaces

• Side returns are not allowed on downflow or horizontal S-SeriesFurnaces

• Mounting flanges must be located on ducting

• Shoot screws through the mount flanges into the furnace cabinet

• Always seal per local codes and requirements

• Furnace, coil, and ducting must be supported separately

• An external overflow drain pan must be installed in all applicationsover a finished ceiling to prevent property damage

Upflow Furnace with Bottom Return in Closet with RemoteFilter

1. Remove the bottom plate.

2. Set the furnace on the base inside closet.

3. Install remote filter.

4. Seal per local codes and requirements.

Upflow Furnace with Bottom Return in Closet with Filter Box

1. Remove the bottom plate.

2. Set the furnace on the filter box inside closet.

3. Must have grille present for air.

4. Seal per local codes and requirements.

FILTER

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 33: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 33

Table 7. Return Duct Connections (continued)

Upflow Furnace with Bottom Return Mounted on a DuctedPedestal

1. Remove the bottom plate.

2. Set the furnace on the ducted pedestal. The ducted pedestal willuse ducted air from a remote location.

3. Install filter at a remote location.

4. Seal per local codes and requirements.

Upflow Furnace with Bottom Return Mounted on a DuctedPedestal with Filter Box

1. Remove the bottom plate.

2. Set the furnace on the filter box. The ducted pedestal will useducted air from a remote location.

3. Seal per local codes and requirements.

FILTER

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 34: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

34 18-CE04D1-1B-EN

Table 7. Return Duct Connections (continued)

Upflow Furnace with Bottom and Side Returns Mounted on aDucted Pedestal with Side Return and Filter Box

Important:Make sure the thermostat wiring hole is sealed on thecabinet side with the side return.

Important:Make sure not to cut the cabinet in the “No Cut” area.

1. Remove the bottom plate.

2. Create ducting and set the furnace in place.

Note: Use Optional BAYLIFT kit to lift furnace. Follow kit instructions.

Note: The furnace bottom pedestal must be a minimum of 6” inheight.

3. Match the filter cabinet flush to the back and bottom sides of thefurnace cabinet and secure in place with screws.

4. Mark the two areas to be cut out for the return air.

5. Cut out the two sections of the cabinet and BAYLIFT kit to beremoved.

6. Attach ducting to the filter box.

7. The ducted pedestal will use ducted air from a remote location.

8. Seal per local codes and requirements.

FILTER

Cabinet cutout when used with BAYLIFT

No Cut Area Cutouts

21” Filter Cabinet with BAYLIFT Kit shown

Flush with backof furnace cabinet

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 35: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 35

Table 7. Return Duct Connections (continued)

Upflow Furnace with Side Return

Important:Make sure the thermostat wiring hole is sealed on thecabinet side with the side return.

Important:Make sure not to cut the cabinet in the “No Cut” area.

1. Using guides, remove the cutout for the side return.

2. Create ducting and set the furnace in place. Use screws to attachducting to the furnace cabinet.

Note: If using a filter box, use a transition, if possible, to attach thefilter box to the furnace cabinet.

3. Seal bottom panel per local codes and requirements.

4. Seal all other panels per local codes and requirements.

Use four corner guidesto create cutout

No Cut Area

Upflow Furnace with Two Side Returns

Important: One of the sides must have a transition to allow thethermostat wiring to exit the cabinet.

Important: If a transition is not a viable option, a hole will need to bedrilled in the side of the cabinet for the thermostat wiringto exit.

Important:Make sure not to cut the cabinet in the “No Cut” area.

Note: If using one transition, the thermostat wiring will exit on thetransition side.

1. Using guides, remove the two cutouts for the side returns.

2. Create ducting and set the furnace in place. Use screws to attachducting to the furnace cabinet.

Note: If using a filter boxes, use transitions, if possible, to attach thefilter boxes to the furnace cabinet.

3. Seal bottom panel per local codes and requirements.

4. Seal all other panels per local codes and requirements.

Use four corner guidesto create cutout

No Cut Area

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 36: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

36 18-CE04D1-1B-EN

Table 7. Return Duct Connections (continued)

Downflow Furnace with Top Return

1. Remove the top plate.

2. Attach the ducting to the top of the furnace.

3. Install remote filter.

4. Seal per local codes and requirements.

Downflow Furnace with Top Return and Plenum

1. Remove the top plate.

2. Attach the plenum ducting to the top of the furnace.

3. Install remote filter.

4. Seal per local codes and requirements.

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 37: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 37

Table 7. Return Duct Connections (continued)

Downflow Furnace with Top Return and Plenumwith Filter Box

1. Remove the top plate.

2. Attach the filter box to the top of the furnace.

3. Attach ducting.

4. Seal per local codes and requirements. FILTER

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 38: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

38 18-CE04D1-1B-EN

Return Air FiltersTYPICAL AIR FILTER INSTALLATIONSFilters are not factory supplied for furnaces. Filter size needed will bedependent on type of filter and CFM requirement. Filters must beinstalled externally to the unit.

Important: It is recommended to transition return ducting to thesame size as the opening. It is acceptable for return ductor filter frame to extend forward of the opening butplastic plugs MUST be installed in any opening that theduct or filter framemay cover.

Return Air Filters

Furnace Width FilterQty and Size

14–1/2” 1 — 14” x 25” x 1”

17–1/2” 1 — 16” x 25” x 1”

21” 1 — 20” x 25” x 1”

24–1/2” 1 — 24” x 25” x 1”

Note: For upflow airflow furnaces where the airflow requirementexceeds 1600 CFM - Furnaces will require return airopenings and filters on: (1) both sides, or (2) one side andthe bottom, or (3) just on the bottom.

Preparation for Upflow Bottom and Side Return Air FilterInstallationsAll return air duct systems should provide for installation of return airfilters.

1. Determine the appropriate position to set the furnace in order toconnect to existing supply and return ductwork.

2. For upflow side return installations, remove the insulation aroundthe opening in the blower compartment

3. The side panels of the upflow furnace include locating notchesthat are used as guides for cutting an opening for return air, referto the figure and the upflow furnace outline drawing for ductconnection dimensions for various furnaces.

4. If a 3/4" flange is to be used for attaching the air inlet duct, add tocut where indicated by dotted lines. Cut corners diagonally andbend outward to form flange.

5. If flanges are not required, and a filter frame is installed, cutbetween locating notches as in illustration.

6. The bottom panel of the upflow furnace must be removed forbottom return air. *

*

*

*

UPFLOW FURNACES ONLY

LOCATINGNOTCHESPROVIDEDFOR SIDERETURNCUTOUT

* SEE OUTLINE DRAWING

FRONTOF FURNACE

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 39: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 39

1. When the furnace is installed in the horizontal right or leftapplication and a return duct is attached to the top side, do notinstall a filter in the return duct directly above the furnace. Installthe filter in a remote location.

When the furnace is installed in the horizontal right or leftapplication and a close coupled (less than 36") return duct isattached to the bottom side of the furnace as shown above,securely attach a 1/2" mesh metal hardware cloth protectivescreen to the inside bottom of the filter grille to preventpersonal injury from contactingmoving parts whenreaching into the return opening to replace the filter.

Close coupled (less than 36") return (filter directly beneathbottom side return) is not recommended due to noiseconsiderations.

2. Connect the duct work to the furnace. See Outline Drawing forsupply and return duct size and location.

Flexible duct connectors are recommended to connect bothsupply and return air ducts to the furnace.

If only the front of the furnace is accessible, it is recommendedthat both supply and return air plenums are removable.

3. When replacing a furnace, old duct work should be cleaned out.Thin cloths should be placed over the registers and the furnacefan should be run for 10 minutes. Don’t forget to remove thecloths before you start the furnace.

4. The horizontal installation of the upflow furnace requiresan external filter section. Filter kits are available forhorizontal applications.

Figure 1. Horizontal upflow furnace with side return

FILTER

CLOSE COUPLED (LESS THAN 36”)RETURN (FILTER DIRECTLY BENEATH BOTTOMSIDE RETURN) NOT RECOMMENDED DUE TO NOISE CONSIDERATIONS. IF USED, SECURELYATTACH 1/2” MESH METAL HARDWARE CLOTHPROTECTIVE SCREEN TO THE INSIDE BOTTOMOF THE FILTER GRILLE.

LESS THAN 36”

RETURN AIR FILTERS FOR FURNACE IN HORIZONTALCONFIGURATIONWhen the Furnace is installed in the horizontal configuration, thereturn air filters must be installed exterior to the furnace cabinet.Remote filter grilles may be used for homeowner convenience or thefilters may be installed in the duct work upstream of the furnace.

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 40: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

40 18-CE04D1-1B-EN

Electrical ConnectionsMake wiring connections to the unit as indicated on enclosed wiring diagram. As with all gas appliances using electrical power, this furnace shallbe connected into a permanently live electric circuit. It is recommended that furnace be provided with a separate "circuit protection device"electric circuit. The furnace must be electrically grounded in accordance with local codes or in the absence of local codes with the NationalElectrical Code, ANSI/NFPA 70 , if an external electrical source is utilized. The integrated furnace control is polarity sensitive. The hot legof the 120V power supply must be connected to the black power lead as indicated on the wiring diagram.Refer to the SERVICE FACTS literature and unit wiring diagram attached to furnace.

Field Wiring

O

Y2

Y1 Y1

B B

W1W1

GG

RR

Y1

Two StageThermostat Furnace

Outdoor Unit(No Transformer)

O

R

X2

Y2

NOTES:1) HP = Wiring used for Heat Pump systems.2) Y1 and/or Y2 must connect from the thermostat to the IFC for proper airflow.3) A/TCONT824 thermostats do not require the use of X2.

HP

HP

HP

FIELD WIRING DIAGRAM FOR S8X1 SINGLE STAGE HEATING THERMOSTAT, ONE / TWO STAGE AC OR HEAT PUMP

Y2

B

O

Y2

Y1 Y1

B B

W2W2

W1W1

GG

RR

O

Y1

Two StageThermostat Furnace

Outdoor Unit(No Transformer)

O

R

X2

Y2

NOTES:1) HP = Wiring used for Heat Pump systems.2) Y1 and/or Y2 must connect from the thermostat to the IFC for proper airflow.3) Remove Y1 - O jumper on IFC for HP systems.4) If the thermostat does not have W2, or there are not enough conductors jumper W1 to W2 at the IFC.5) A/TCONT824 thermostats do not require the use of X2.

HP

HP

HP

HP

FIELD WIRING DIAGRAM FOR S8X2 TWO STAGE HEATING THERMOSTAT, ONE / TWO STAGE AC OR HEAT PUMP

Y2

B

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 41: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 41

Twinning

TWINNING CONNECTION DIAGRAMFOR TWINNING S-SERIES FURNACES

2 STAGE HEAT / 1 STAGE COOLING THERMOSTAT

2 STAGE HEATING1 STAGE COOLING

THERMOSTAT FURNACE NO. 1 FURNACE NO. 2

R2

R2

ISOLATION RELAY

R1R1

1 STAGE ODU(NO TRANSFORMER)

Y1

B

Y1 Y1 Y1

W1 W1 W1

W2 W2 W2

R R R

G G G

B B B

NOTES:1. BOTH FURNACES MUST BE POWERED FROM THE SAME 115 VAC PHASE LEG AT THE CIRCUIT BREAKER.2. TRANSFORMERS MUST BE IN PHASE. - MEASURE THE VOLTAGE BETWEEN THE “R” TERMINALS ON BOTH FURNACES, VOLTAGE SHOULD BE LESS THAN 10 VOLTS. - IF GREATER, REVERSE THE LOW VOLTAGE ON ONE OF THE TRANSFORMERS AND RECHECK.3. HEATING AND COOLING AIRFLOW MUST BE THE SAME FOR BOTH FURNACES.4. OD UNIT TYPE SETUP MUST BE THE SAME FOR BOTH FURNACES.

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 42: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

42 18-CE04D1-1B-EN

TWINNING CONNECTION DIAGRAMFOR TWINNING S-SERIES FURNACES

2 STAGE HEAT / 2 STAGE COOLING THERMOSTAT

2 STAGE HEATING1 STAGE COOLING

THERMOSTAT FURNACE NO. 1 FURNACE NO. 2

R2

R2

ISOLATION RELAY(FIELD SUPPLIED)

ISOLATION RELAY

R1R1

2 STAGE ODU(NO TRANSFORMER)

Y2

Y1

Y1 Y1 Y1

B

Y2 Y2 Y2

W1 W1 W1

W2 W2 W2

R R R

G G G

B B B

NOTES:1. BOTH FURNACES MUST BE POWERED FROM THE SAME 115 VAC PHASE LEG AT THE CIRCUIT BREAKER.2. TRANSFORMERS MUST BE IN PHASE. - MEASURE THE VOLTAGE BETWEEN THE “R” TERMINALS ON BOTH FURNACES, VOLTAGE SHOULD BE LESS THAN 10 VOLTS. - IF GREATER, REVERSE THE LOW VOLTAGE ON ONE OF THE TRANSFORMERS AND RECHECK.3. HEATING AND COOLING AIRFLOW MUST BE THE SAME FOR BOTH FURNACES.4. OD UNIT TYPE SETUP MUST BE THE SAME FOR BOTH FURNACES.

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 43: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 43

TWINNING CONNECTION DIAGRAMFOR TWINNING S-SERIES FURNACES

2 STAGE HEAT / 1 STAGE COOLING (WITH TRANSFORMER) THERMOSTAT

2 STAGE HEATING1 STAGE COOLING

THERMOSTAT FURNACE NO. 1 FURNACE NO. 2

R2

R2

ISOLATION RELAY(FIELD SUPPLIED)

ISOLATION RELAY

R1R1

Y1B

Y1 Y1 Y1

W1 W1 W1

W2 W2 W2

R R R

G G G

B B B

NOTES:1. BOTH FURNACES MUST BE POWERED FROM THE SAME 115 VAC PHASE LEG AT THE CIRCUIT BREAKER.2. TRANSFORMERS MUST BE IN PHASE. - MEASURE THE VOLTAGE BETWEEN THE “R” TERMINALS ON BOTH FURNACES, VOLTAGE SHOULD BE LESS THAN 10 VOLTS. - IF GREATER, REVERSE THE LOW VOLTAGE ON ONE OF THE TRANSFORMERS AND RECHECK.3. HEATING AND COOLING AIRFLOW MUST BE THE SAME FOR BOTH FURNACES.4. OD UNIT TYPE SETUP MUST BE SET FOR 1-1.

From Dwg. 21B341337 Rev. 2

OUTDOOR UNIT(WITH TRANSFORMER)

RC

ISOLATION RELAY(FIELD SUPPLIED)

ALTERNATE CONNECTION

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 44: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

44 18-CE04D1-1B-EN

TWINNING CONNECTION DIAGRAMFOR TWINNING S-SERIES FURNACES

2 STAGE HEAT / 1 STAGE COOLING THERMOSTATWITH SINGLE STAGE THERMOSTAT

2 STAGE HEATING1 STAGE COOLING

THERMOSTAT FURNACE NO. 1 FURNACE NO. 2

SEE NOTE 5

R1

ISOLATION RELAY(FIELD SUPPLIED)

ISOLATION RELAY

R1R1

1 STAGE ODU(NO TRANSFORMER)

Y1

B

Y1 Y1 Y1

W1 W1 W1

W2 W2 W2

R R R

G G G

B B B

NOTES:1. BOTH FURNACES MUST BE POWERED FROM THE SAME 115 VAC PHASE LEG AT THE CIRCUIT BREAKER.2. TRANSFORMERS MUST BE IN PHASE. - MEASURE THE VOLTAGE BETWEEN THE “R” TERMINALS ON BOTH FURNACES, VOLTAGE SHOULD BE LESS THAN 10 VOLTS. - IF GREATER, REVERSE THE LOW VOLTAGE ON ONE OF THE TRANSFORMERS AND RECHECK.3. HEATING AND COOLING AIRFLOW MUST BE THE SAME FOR BOTH FURNACES.4. OD UNIT TYPE SETUP MUST BE THE SAME FOR BOTH FURNACES.5. WHEN USING A SINGLE STAGE THERMOSTAT, JUMPER W1/W2 TOGETHER. THE INTERSTAGE DELAY MUST BE SET THE SAME FOR BOTH UNITS.

FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Page 45: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 45

General Start-up and AdjustmentThe following sections give instructions for the generalstart-up and adjustment of the gas furnaces.

Preliminary Inspections

With gas and electrical power "OFF", ensure:

1. Duct connections are properly sealed.

2. Filters are in place.

3. Venting is properly assembled.

4. Blower vestibule panel is in place and all screws in place.

Turn knob on main gas valve within the unit to the "OFF" position.Turn the external gas valve to "ON". Purge the air from the gas lines.After purging, check all gas connections for leaks with a soapysolution.— DO NOT CHECKWITH AN OPEN FLAME. Allow 5minutes for anygas that might have escaped to dissipate. Turn the gas valve in theunit to the "ON" position.

Propane Gas being heavier than air may require forced ventilation.Turn the toggle switch on the Gas Valve in the unit to the “ON”position.

Lighting InstructionsLighting instructions appear on each unit. Each installation must bechecked out at the time of initial start up to ensure proper operation ofall components. Check out should include putting the unit through onecomplete cycle as outlined below.Turn on the main electrical supply and set the comfort control abovethe indicated temperature. The ignitor will automatically heat, thenthe gas valve is energized to permit the flow of gas to the burners.After ignition and flame is established, the flame control modulemonitors the flame and supplies power to the gas valve until thecomfort control is satisfied.

WWAARRNNIINNGGFFIIRREE OORR EEXXPPLLOOSSIIOONN HHAAZZAARRDD!!FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorr ddeeaatthh..DDoo NNOOTT aatttteemmpptt ttoo mmaannuuaallllyy lliigghhtt tthhee ffuurrnnaaccee..

To shut offFor complete shutdown: Turn the toggle or control switch located onthe main gas valve inside the unit to the "OFF" position and theexternal main gas shutoff valve to the "OFF" position. Disconnect theelectrical supply to the unit.

Whenever your house is to be vacant, arrange to have someoneinspect your house for proper temperature. This is very importantduring freezing weather. If for any reason your furnace should fail tooperate damage could result, such as frozen water pipes.

CCAAUUTTIIOONNFFRREEEEZZEE CCAAUUTTIIOONN!!FFaaiilluurree ttoo ffoollllooww tthhiiss CCaauuttiioonn ccoouulldd rreessuulltt iinnpprrooppeerrttyy ddaammaaggee oorr ppeerrssoonnaall iinnjjuurryy..IIff ccoommpplleettee ffuurrnnaaccee sshhuuttddoowwnn iiss ddoonnee dduurriinngg tthheeccoolldd wweeaatthheerr mmoonntthhss,, pprroovviissiioonnss mmuusstt bbee ttaakkeenn ttoopprreevveenntt ffrreeeezzee--uupp ooff aallll wwaatteerr ppiippeess aanndd wwaatteerrrreecceeppttaacclleess..

Control and Safety SwitchAdjustmentLIMIT SWITCH CHECK OUTThe limit switch is a safety device designed to close the gas valveshould the furnace become overheated. Since proper operation of thisswitch is important to the safety of the unit, itmust be checked outon initial start up by the installer.

To check for proper operation of the limit switches, set the thermostatto a temperature higher than the indicated temperature to bring onthe gas valve. Restrict the airflow by blocking the return air to theblower. When the furnace reaches the maximum outlet temperatureas shown on the rating plate, the burners must shut off. If they do notshut off after a reasonable time and overheating is evident, a faultylimit switch is probable and the limit switch must be replaced. Afterchecking the operation of the limit control, be sure to remove thepaper or cardboard from the return air inlet, or reconnect the blower.

Page 46: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

46 18-CE04D1-1B-EN

Furnace Combustion Air Exhaust Options

Note: Default is left side for electric and gas connections.

The following sections give instructions for thedifferent furnace orientations and the options forventing the exhaust combustion air.

IImmppoorrttaanntt:: When looking at the different orientations,the direction of the combustion air exhaustin the illustration’s description is after thefurnace has been rotated, if needed.

Table 8. Venting Options for Upflow Applications

Refer to the illustrations below to find the approved venting options for upflow furnace.

Important: The exhaust must be vented to the outdoors.

Upflow Orientation or Installation

Vented out top.

Vented through left side.

Vented through right side.

Page 47: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 47

Table 9. Venting Options for Horizontal Left Applications

Refer to the illustrations below to find the approved venting options for horizontal left furnace.

Important: The exhaust must be vented to the outdoors.

Horizontal Left Orientation or Installation

Vented out top.

Vented through left side.

Table 10. Venting Options for Horizontal Right Applications

Refer to the illustrations below to find the approved venting options for horizontal right furnace.

Important: The exhaust must be vented to the outdoors.

Horizontal Right Orientation or Installation

Vented out top.

Vented through right side.

FFuurrnnaaccee CCoommbbuussttiioonn AAiirr EExxhhaauusstt OOppttiioonnss

Page 48: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

48 18-CE04D1-1B-EN

Table 11. Venting Options for Downflow Applications

Refer to the illustrations below to find the approved venting options for downflow furnacemodels.

Important: The combustion air exhaust must be vented to the outdoors.

Downflow Orientation or Installation

Vented out top.

Note: Requires kit BAYVENT600. Kit used with B, C, and D cabinetsonly.

Note: “A” cabinet furnaces must be vented through the left of rightside openings.

Note: 4” Type B double wall vent pipe must be used inside of thefurnace cabinet.

Vented through left side.

Vented through right side.

FFuurrnnaaccee CCoommbbuussttiioonn AAiirr EExxhhaauusstt OOppttiioonnss

Page 49: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 49

Combustion Air ConversionsImportant: After deciding the orientation of the flue outlet, cut the

metal tabs around the appropriate 5” metal cutout on thefurnace cabinet and remove the cutout, if necessary.

Note:When rotating the inducer it may be necessary to cut the wiretie. A new wire tie must be installed once the inducer is rotated.

Note: Self-tapping screws are recommended for attaching the ventpipe to the inducer outlet.

Pressure Switch locationsS8X1: PS is connected to the hot header.S8X2: PS1 is connected to the inducer. PS2 is connected to the hotheader.

Upflow orientation with top ventingNo changes need to be made to the inducer when installing thefurnace in upflow position when vented through the top.

Note: Self-tapping screws are recommended for attaching the ventpipe to the inducer outlet.

Upflow orientation with left side ventingBefore proceeding, lay unit on its back to make the conversion easier.The following changes need to be made to the inducer when installingthe furnace in upflow position with the combustion air vented out theleft side.

Note:When rotating the inducer it may be necessary to cut the wiretie. A new wire tie must be installed once the inducer is rotated.

1. Remove the four screws holding the inducer in place.

2. Rotate the inducer so the inducer outlet is pointing towards the 5”cutout.

3. Secure the inducer in place using the screws removed in step 1.

4. Attach the vent to the inducer outlet.

Note: Self-tapping screws are recommended for attaching the ventpipe to the inducer outlet.

Upflow orientation with right side ventingBefore proceeding, lay unit on its back to make the conversion easier.The following changes need to be made to the inducer when installingthe furnace in upflow position with the combustion air vented out theleft side.

1. Remove the four screws holding the inducer in place.

2. Rotate the inducer so the inducer outlet is pointing towards the 5”cutout.

3. Secure the inducer in place using the screws removed in step 1.

4. Attach the vent to the inducer outlet.

Note: Self-tapping screws are recommended for attaching the ventpipe to the inducer outlet.

FFuurrnnaaccee CCoommbbuussttiioonn AAiirr EExxhhaauusstt OOppttiioonnss

Page 50: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

50 18-CE04D1-1B-EN

Horizontal left orientation with left side ventingNo changes need to be made to the inducer when installing thefurnace in upflow position with the combustion air vented through thetop.

Note: Self-tapping screws are recommended for attaching the ventpipe to the inducer outlet.

Horizontal left orientation with top ventingBefore proceeding, lay unit on its back to make the conversion easier.The following changes need to be made to the inducer when installingthe furnace in upflow position with the combustion air vented out theleft side.

1. Remove the four screws holding the inducer in place.

2. Rotate the inducer so the inducer outlet is pointing towards the 5”cutout.

3. Secure the inducer in place using the screws removed in step 1.

4. Attach the vent to the inducer outlet.

Note: Self-tapping screws are recommended for attaching the ventpipe to the inducer outlet.

Horizontal right orientation with right side ventingNo changes need to be made to the inducer when installing thefurnace in upflow position with the combustion air vented through thetop.

Note: Self-tapping screws are recommended for attaching the ventpipe to the inducer outlet.

FFuurrnnaaccee CCoommbbuussttiioonn AAiirr EExxhhaauusstt OOppttiioonnss

Page 51: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 51

Horizontal right orientation with top ventingBefore proceeding, lay unit on its back to make the conversion easier.The following changes need to be made to the inducer when installingthe furnace in upflow position with the combustion air vented out theleft side.

1. Remove the four screws holding the inducer in place.

2. Rotate the inducer so the inducer outlet is pointing towards the 5”cutout.

3. Secure the inducer in place using the screws removed in step 1.

4. Attach the vent outlet gasket to the vent outlet.

Note: Self-tapping screws are recommended for attaching the ventpipe to the inducer outlet.

Downflow orientation with left side ventingBefore proceeding, lay unit on its back to make the conversion easier.The following changes need to be made to the inducer when installingthe furnace in upflow position with the combustion air vented out theleft side.

1. Remove the four screws holding the inducer in place.

2. Rotate the inducer so the inducer outlet is pointing towards the 5”cutout.

3. Secure the inducer in place using the screws removed in step 1.

4. Attach the vent to the inducer outlet.

Note: Self-tapping screws are recommended for attaching the ventpipe to the inducer outlet.

FFuurrnnaaccee CCoommbbuussttiioonn AAiirr EExxhhaauusstt OOppttiioonnss

Page 52: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

52 18-CE04D1-1B-EN

Downflow orientation with right side ventingBefore proceeding, lay unit on its back to make the conversion easier.The following changes need to be made to the inducer when installingthe furnace in upflow position with the combustion air vented out theleft side.

1. Remove the four screws holding the inducer in place.

2. Rotate the inducer so the inducer outlet is pointing towards the 5”cutout.

3. Secure the inducer in place using the screws removed in step 1.

4. Attach the vent to the inducer outlet.

Note: Self-tapping screws are recommended for attaching the ventpipe to the inducer outlet.

Downflow orientation with top ventingBefore proceeding, lay unit on its back to make the conversion easier.The following changes need to be made to the inducer when installingthe furnace in upflow position with the combustion air vented out theleft side.

Note: Requires kit BAYVENT600. Kit used with B, C, and D cabinetsonly. Follow kit instructions for installation.

Note: 4” Type B double wall vent pipe must be used inside of thefurnace cabinet.

1. Remove the four screws holding the inducer in place.

2. Rotate the inducer so the inducer outlet is pointing towards the 5”cutout.

3. Install BAYVENT600 kit per the kit instructions.

4. Attach the vent to the inducer outlet.

Note: Self-tapping screws are recommended for attaching the B Ventto the inducer outlet.

FFuurrnnaaccee CCoommbbuussttiioonn AAiirr EExxhhaauusstt OOppttiioonnss

Page 53: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 53

Integrated Furnace Control MenuST

ATU

S M

ENU

ACTI

VE E

RRO

RS

Exam

ple

Gas

Hea

tEx

ampl

eTa

p 5

Exam

ple

Pres

sure

Sw

itch

Erro

r

LAST

6 F

AULT

S

Exam

ple

Pres

sure

Sw

itch

Erro

rEx

ampl

eO

pen

Lim

it Sw

itch

Erro

r

Cont

rol R

elea

se #

Exam

ple

So!

war

e Ve

rsio

n #

Cooi

ng O

ff D

elay

Exam

ple

seco

nds

Out

door

Sta

ges

Hea

t Off

Del

ay

Exam

ple

seco

nds

Inte

r-St

age

Del

ay

Exam

ple

seco

nds

Con$

nuou

s Fa

n Ta

p

Exam

ple

Tap

#

Com

pres

sor O

pera

$on

Spee

d Ta

p

Exam

ple

Tap

#

Exam

ple

1stSt

age

Tap

#

Hea

$ng

Spee

d Ta

p

Exam

ple

Sing

le S

tage

Exam

ple

2 st

age

1 co

mpr

esso

r

Run

Test

Mod

e

LED

Orie

nta$

on

S8X1

Con

trol

Sys

tem

Men

u Si

ngle

Sta

ge O

D

SETT

ING

UP

YOU

R SY

STEM

:To

cha

nge

any

fact

ory

defa

ult v

alue

, firs

t rem

ove

any

“cal

l” fr

om th

e fu

rnac

e an

d al

low

all

fan

off d

elay

s to

fini

sh. (1

DL s

houl

d be

see

n on

the

disp

lay)

.

Scro

ll to

the

sele

cted

Men

u ite

m b

y m

omen

taril

y de

pres

sing

the

“MEN

U”

key

and

then

dep

ress

the

“OPT

ION

” ke

y to

the

desi

red

se&

ng. T

hen

mom

enta

rily

depr

ess

the

“MEN

U”

key

agai

n to

sav

e th

e ch

ange

.

CLEA

RIN

G T

HE

LAST

6 F

AULT

S:To

cle

ar th

e st

ored

faul

ts, s

crol

l to

the

last

6 fa

ults

men

u, e

nter

the

men

u by

scr

ollin

g to

the

right

and

hol

d th

e “O

p$on

” ke

y fo

r at l

east

5 s

econ

ds.

Rele

ase

and

a se

t of 3

das

hes

will

be

seen

3 $

mes

. Thi

s co

nfirm

s th

e fa

ults

hav

e be

en c

lear

ed.

SELE

CTIN

G C

OO

LIN

G /

HP

FAN

SPE

EDS

for 1

-1 O

DU

:Sc

roll

to th

e CO

Pm

enu

and

mom

enta

rily

push

the

OPT

ION

key

. Tap

7 is

the

defa

ult

se&

ng fo

r all

mod

els.

Whe

n se

lec$

on is

mad

e, m

omen

taril

y pu

sh th

e M

ENU

key

to

save

.

Def

ault

Airfl

ow T

aps

Gas

Hea

t = T

ap 5

OD

U M

enu

1-1

Cool

ing

/ H

P =

Tap

7

SELE

CTIN

G G

AS H

EATI

NG

FAN

SPE

EDS:

Scro

ll to

the HT

P m

enu

and

mom

enta

rily

push

the

OPT

ION

key

. Tap

#5

is th

e de

faul

t se&

ng fo

r all

mod

els.

Whe

n se

lec$

on is

mad

e, m

omen

taril

y pu

sh th

e M

ENU

key

to s

ave.

NO

TE: T

ap 9

is n

ot a

vaila

ble

for g

as h

ea$n

g.

Page 54: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

54 18-CE04D1-1B-EN

Exam

ple

Tap

#

STAT

US

MEN

U

ACTI

VE E

RRO

RS

Exam

ple

Gas

Hea

tEx

ampl

eTa

p 5

Exam

ple

Pres

sure

Sw

itch

Erro

r

LAST

6 F

AULT

S

Exam

ple

Pres

sure

Sw

itch

Erro

r

Exam

ple

Ope

n Li

mit

Switc

h Er

ror

Cont

rol R

elea

se #

Exam

ple

So!

war

e Ve

rsio

n #

Cooi

ng O

ff D

elay

Exam

ple

seco

nds

Out

door

Sta

ges

Hea

t Off

Del

ay

Exam

ple

seco

nds

Inte

r-St

age

Del

ay

Exam

ple

seco

nds

Con$

nuou

s Fa

n Ta

p

Exam

ple

Tap

#

Com

pres

sor O

pera

$on

Spee

d Ta

p

Exam

ple

Tap

#

S8X1

Con

trol

Sys

tem

Men

u Tw

o St

age

OD

SETT

ING

UP

YOU

R SY

STEM

:To

cha

nge

any

fact

ory

defa

ult v

alue

, firs

t rem

ove

any

“cal

l” fr

om th

e fu

rnac

e an

d al

low

all

fan

off d

elay

s to

fini

sh. (1

DL s

houl

d be

see

n on

the

disp

lay)

.

Scro

ll to

the

sele

cted

Men

u ite

m b

y m

omen

taril

y de

pres

sing

the

“MEN

U”

key

and

then

dep

ress

the

“OPT

ION

” ke

y to

the

desi

red

se&

ng. T

hen

mom

enta

rily

depr

ess

the

“MEN

U”

key

agai

n to

sav

e th

e ch

ange

.

CLEA

RIN

G T

HE

LAST

6 F

AULT

S:To

cle

ar th

e st

ored

faul

ts, s

crol

l to

the

last

6 fa

ults

men

u, e

nter

the

men

u by

scr

ollin

g to

the

right

and

hol

d th

e “O

p$on

” ke

y fo

r at l

east

5 s

econ

ds.

Rele

ase

and

a se

t of 3

das

hes

will

be

seen

3 $

mes

. Thi

s co

nfirm

s th

e fa

ults

hav

e be

en c

lear

ed.

SELE

CTIN

G C

OO

LIN

G /

HP

FAN

SPE

EDS

for 2

-1 O

DU

:1st

Sta

ge A

irflow

: Scr

oll t

o th

e CO

Pm

enu

and

mom

enta

rily

push

the

OPT

ION

key

. Tap

#3

is th

e de

faul

t 1st s

tage

se&

ng fo

r all

mod

els.

Whe

n se

lec$

on is

mad

e, m

omen

taril

y pu

sh th

e M

ENU

key

to s

ave.

2nd S

tage

Airfl

ow: A

!er

1st s

tage

airfl

ow is

sel

ecte

d, th

e de

faul

t 2nd

sta

ge a

irflow

tap

will

ap

pear

, C2_

7. I

f thi

s ta

p is

des

ired,

mom

enta

rily

push

the

MEN

U k

ey to

sav

e.

Imp

ort

ant:

If a

chan

ge is

mad

e to

eith

er 1

st o

r 2nd

sta

ge a

irflow

, bot

h m

ust b

e sa

ved

by

push

ing

the

MEN

U k

ey. N

eith

er s

elec

$on

will

be

save

d if

this

is n

ot d

one.

Def

ault

Airfl

ow T

aps

Gas

Hea

t = T

ap 5

OD

U M

enu

2-1

1st S

tage

Coo

ling

/ H

P =

Tap

32nd

Sta

ge C

oolin

g /

HP

= Ta

p 7

SELE

CTIN

G G

AS H

EATI

NG

FAN

SPE

EDS:

Scro

ll to

the HT

P m

enu

and

mom

enta

rily

push

the

OPT

ION

key

. Tap

#5

is th

e de

faul

t se&

ng fo

r all

mod

els.

Whe

n se

lec$

on is

mad

e, m

omen

taril

y pu

sh th

e M

ENU

key

to s

ave.

NO

TE: T

ap 9

is n

ot a

vaila

ble

for g

as h

ea$n

g.

Hea

$ng

Spee

d Ta

p

Exam

ple

Sing

le S

tage

Exam

ple

2 st

age

1 co

mpr

esso

r

Run

Test

Mod

e

LED

Orie

nta$

on

IInntteeggrraatteedd FFuurrnnaaccee CCoonnttrrooll MMeennuu

Page 55: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 55

Orn

Htp

C0P

CFP

1 Sd

HOd

Ht1

tp3

Exam

ple

1st s

tage

Gas

Hea

tEx

ampl

eTa

p 3

E3.4

Exam

ple

2nd S

tage

Pre

ssur

e Sw

itch

Er

ror

E3.1

Exam

ple

1st

Stag

e Pr

essu

re S

wit

ch

Erro

r

E3.4

E3.1

E04

Exam

ple

2nd S

tage

Pre

ssur

e Sw

itch

Er

ror

Exam

ple

1st

Stag

e Pr

essu

re S

wit

ch

Erro

r

Exam

ple

Ope

n Li

mit

Sw

itch

Err

or

CR

Exam

ple

So!

war

e V

ersi

on #

000

090

180

Exam

ple

seco

nds

1-1

2-1

100

060

Exam

ple

seco

nds

Inte

r-S

tag

e D

ela

y60

000

0

Exam

ple

seco

nds

300

900

Contin

uou

s F

an T

ap

CF.1

Exam

ple

Tap

#

Co

mp

ress

or

Op

era

tion

S

peed T

ap

Exam

ple

Tap

#

Exam

ple

1st S

tage

Tap

#

rUn

S8

X2

Co

ntr

ol S

yste

m M

en

u S

ing

le S

tag

e O

D

140

180

C1.7

C1.1

C1.2

C1.3

C1.4

Heatin

g S

pee

d T

ap

H1.2

H1.1

001

H1.3

H2.6

H1.4

Exam

ple

Sing

le S

tage

Exam

ple

2 st

age

1 co

mpr

esso

r

Run T

est

Mo

de

C1.5

C1.6

C1.8

C1.9

H2_7

H2.8

H2.5

LE

D O

rie

nta

tion

UPdn

SE

LE

CT

ING

CO

OL

ING

/ H

P F

AN

SP

EE

DS

FO

R 1

-1 O

DU

Scr

oll

to t

he

CO

P m

enu

an

d m

om

en

tari

ly p

ush

th

e O

PT

ION

key.

Ta

p 7

is t

he

de

fau

lt se

ttin

g fo

r a

ll m

od

els

. Wh

en

se

lect

ion

is m

ad

e,

me

me

nta

rily

pu

sh t

he

ME

NU

key

to s

ave

.

De

fau

lt A

irflo

w T

ap

s

1st

Sta

ge

Ga

s H

ea

t =

Ta

p 2

2n

d S

tag

e G

as

He

at

= T

ap

5

OD

U M

enu

1-1

Co

olin

g/H

P =

Ta

p 7

CL

EA

RIN

G T

HE

LA

ST

6 F

AU

LTS

:To

cle

ar

the

sto

red

fa

ults

, sc

roll

to th

e r

igh

ta

nd

ho

ld t

he

“O

ptio

n”

key

for

at

lea

st 5

se

con

ds.

Re

lea

se a

nd

a s

et

of

3 d

ash

es

will

be

se

en

3 t

ime

s.T

his

co

nfir

ms

the

fa

ults

have

be

en

cle

are

d.

SE

TT

ING

UP

YO

UR

SY

ST

EM

:To

ch

an

ge

any

fact

ory

de

fau

lt va

lue,

first

re

move

any

“ca

ll” f

rom

th

e f

urn

ace

an

d a

llow

all

fan

off

d

ela

ys t

o f

inis

h. (1D

L sh

ou

ld b

e s

ee

n o

n t

he

dis

pla

y)

Scr

oll

to t

he

se

lect

ed

Me

nu

ite

m b

y m

om

en

tari

lyd

ep

ress

ing

th

e “

ME

NU

” ke

y a

nd

th

en

de

pre

ss t

he

“O

PT

ION

”ke

y to

th

e d

esi

red

se

ttin

g. T

he

n m

om

en

tari

ly d

ep

ress

the

“M

EN

U”

key

ag

ain

to

save

th

e c

ha

ng

e.

SE

LE

CT

ING

GA

S H

EAT

FA

N S

PE

ED

S:

1st

Sta

ge

Airflo

w: S

cro

ll to

th

e Htp

me

nu

an

d m

om

en

tari

ly p

ush

th

e O

PT

ION

ke

y.T

ap

#2

is t

he

de

fau

lt 1

st s

tag

e s

ett

ing

fo

r a

ll m

od

els

. W

he

n s

ele

ctio

n is

ma

de

,m

om

en

tari

ly p

ush

th

e M

EN

U k

ey

to s

ave

.2

nd

Sta

ge

Air

flow

: A

fte

r 1

st s

tag

e a

irflo

w is

se

lect

ed

, th

e d

efa

ult

2n

d s

tag

e a

irflo

wta

p w

ill a

pp

ea

r, H2_

5. I

f th

is t

ap

is d

esi

red

, m

om

en

tari

ly p

ush

th

e M

EN

U k

ey

to s

ave

.

No

te:

Ta

p 9

is n

ot

ava

ilab

le f

or

he

atin

g.

Imp

ort

an

t: I

f a

ch

an

ge

is m

ad

e t

o e

ithe

r 1

or

2 s

tag

e a

irflo

w,

bo

th m

ust

be

sa

ved

by

pu

shin

g M

EN

U k

ey.

Ne

ithe

r se

lect

ion

will

be

sa

ved

if t

his

is n

ot

do

ne

.

1DL

Sta

tus

Me

nu

Act

ive

Err

ors

La

st 6

Fa

ults

L6F

Err

Cr1

Co

ntr

ol R

ele

ase

#

C0d

Co

olin

g O

ff D

ela

y

Ou

tdo

or

Sta

ge

s

He

at

Off

De

lay

OdU

IInntteeggrraatteedd FFuurrnnaaccee CCoonnttrrooll MMeennuu

Page 56: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

56 18-CE04D1-1B-EN

Exam

ple

1st S

tag

e T

ap #

ST

AT

US

ME

NU

AC

TIV

E E

RR

OR

S

Ht1

tp2

Exam

ple

1st sta

ge G

as H

eat

Exam

ple

Ta

p 3

E3.4

Exam

ple

2nd

Sta

ge

Pre

ssu

re S

witch

E

rror

E3.1

Exam

ple

1st

Sta

ge P

ressure

Sw

itch

Err

or

LA

ST

6 F

AU

LT

SE3.4

E3.1

E04

Exam

ple

2nd

Sta

ge P

ressu

re S

witch

E

rror

Exam

ple

1st

Sta

ge P

ressure

Sw

itch

Err

or

Exam

ple

Op

en

Lim

it S

witch

Err

or

Co

ntr

ol R

ele

ase

#CR

Exam

ple

Soft

wa

re V

ers

ion #

Co

oin

g O

ff D

ela

y000

090

180

Exam

ple

seconds

Outd

oor

Sta

ges

1-1

2-1

Heat

Off D

ela

y100

060

Exam

ple

seconds

Inte

r-S

tag

e D

ela

y600

000

Exam

ple

seconds

300

900

Continuou

s F

an T

ap

CF.1

Exam

ple

Tap #

Co

mp

resso

r O

pe

ratio

n

Speed T

ap

Exam

ple

Tap #

S8X

2 C

ontr

ol S

yste

m M

enu T

wo

Sta

ge

OD

140

180

C1.3

C1.1

C1.2

C2.7

C2.4

Heating

Spee

d T

ap

H1.2

H1.1

001

H1.3

H2.6

H1.4

Exam

ple

sin

gle

sta

ge

Exam

ple

2 s

tage 1

com

pre

sso

r

Run T

est M

ode

C2.5

C2.6

C2.8

C2.9

H2_7

H2.8

H2.5

LE

D O

rie

nta

tio

nUP

dn

SE

TT

ING

UP

YO

UR

SY

ST

EM

:To

ch

an

ge

any fa

cto

ry d

efa

ult v

alu

e,

firs

t re

move

any “

ca

ll” f

rom

th

e f

urn

ace

an

d a

llow

all

fan

off

de

lays t

o

fin

ish

. (1DL s

ho

uld

be

se

en

on

th

e d

isp

lay)

Scro

ll to

th

e s

ele

cte

d M

enu

ite

m b

y m

om

en

tari

ly d

ep

ressin

g t

he

“M

EN

U”

key a

nd

th

en

de

pre

ss t

he

“O

PT

ION

” ke

y t

o t

he

de

sire

d s

ett

ing

. Th

en

mo

me

nta

rily

de

pre

ss t

he

“M

EN

U”

key a

ga

in t

o s

ave

th

e c

ha

ng

e.

CL

EA

RIN

G T

HE

LA

ST

6 F

AU

LTS

:To

cle

ar

the

sto

red

fa

ults,

scro

ll to

th

e la

st

6 fa

ults m

enu

, e

nte

r th

e m

enu

by s

cro

llin

g t

o t

he

rig

ht

an

d

ho

ld t

he

“O

ptio

n”

key fo

r a

t le

ast

5 s

eco

nd

s. R

ele

ase

an

d a

se

t o

f 3

da

sh

es w

ill b

e s

ee

n 3

tim

es.

Th

is

co

nfirm

s t

he

fa

ults h

ave

be

en

cle

are

d.

De

fau

lt A

irflo

w T

ap

s

1st

Sta

ge

Ga

s H

ea

t =

Ta

p 2

2n

d S

tag

e G

as

He

at

= T

ap

5

OD

U M

enu

2-1

1st

Sta

ge

Co

olin

g/H

P =

Ta

p 3

2n

d S

tag

e C

oo

ling

/HP

= T

ap

7

SE

LEC

TIN

G C

OO

LIN

G/H

P F

AN

SP

EE

DS

FO

R 2

-1 O

DU

1st S

tage

Airf

low

: Scr

oll t

o th

e C

OP

men

u an

d m

omen

taril

y pu

sh th

e O

PT

ION

key

. Tap

#3

is th

e de

faul

t 1st

sta

ge s

et-

ting

for

all m

odel

s. W

hen

sele

ctio

n is

mad

e, m

omen

taril

y pu

sh th

e M

EN

U k

ey to

sav

e. 2

nd S

tage

Airf

low

: Afte

r 1s

t sta

ge

airf

low

is s

elec

ted,

the

defa

ult 2

nd s

tage

airf

low

tap

will

app

ear, C2

_7. I

f thi

s ta

p is

des

ired,

mom

enta

rily

push

the

ME

NU

ke

y to

sav

e.

Impo

rtan

t: If

a ch

ange

is m

ade

to e

ither

1st

or

2nd

stag

e ai

rflo

w, b

oth

mus

t be

save

d by

pus

hing

the

ME

NU

key

. Nei

ther

se

lect

ion

will

be

save

d if

this

is n

ot d

one.

1DL

Err

L6F

Cr1

C0d

OdU

HOd

1 5d

CFP

COP

HTP

OrN

rUn

SE

LE

CT

ING

GA

S H

EA

T F

AN

SP

EE

DS

:1

st

Sta

ge

Air

flo

w:

Scro

ll t

o t

he

HT

P m

en

u a

nd

mo

me

nta

rily

pu

sh

th

e O

PT

ION

ke

y.

Ta

p #

2 is t

he

de

fau

lt

1st

sta

ge

se

ttin

g f

or

all m

od

els

. W

he

n s

ele

ctio

n is m

ad

e,

mo

me

nta

rily

pu

sh

th

e M

EN

U k

ey t

o s

ave

.2

nd

Sta

ge

Air

flo

w:

Aft

er

1st

sta

ge

air

flo

w is s

ele

cte

d,

the

de

fau

lt 2

nd

sta

ge

air

flo

w t

ap

will a

pp

ea

r, H

2_

5.

If t

his

ta

p is d

esir

ed

, m

om

en

tari

ly p

ush

th

e M

EN

U k

ey t

o s

ave

. T

ap

s 3

an

d 4

are

als

o a

va

ila

ble

.

NO

TE

: T

ap

9 is n

ot

ava

ila

ble

fo

r g

as h

ea

tin

g.

Imp

ort

an

t: I

f a

ch

an

ge

is m

ad

e t

o e

ith

er

1st

or

2n

d

sta

ge

air

flo

w,

bo

th m

ust

be

sa

ve

d b

y p

ush

ing

th

e

ME

NU

ke

y.

Ne

ith

er

se

lectio

n w

ill b

e s

ave

d if

this

is n

ot

do

ne

IInntteeggrraatteedd FFuurrnnaaccee CCoonnttrrooll MMeennuu

Page 57: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 57

Ht1 TP2

Ht2 Tp4

CL1 TP3

CL2 TP7

HP1 TP3

HP2 Tp7

COF Tp1

DFT TP3

S8X1 - S8X2 System Status Menu

ExampleTap #2

e3.1

Example1st Stage Pressure

Switch Error1dL

IdL = Idle, no demand for cooling, heating, or fanHt1 = Demand for 1st stage gas heat (HT = S8X1)Ht2 = Demand for 2nd gas heatCL1 = Demand for 1st stage cooling (CP1 = S8X1)CL2 = Demand for 2nd stage cooling (CP2 = S8X1)HP1 = Demand for 1st stage gas heat pump (CP1 = S8X1)HP2 = Demand for 2nd stage heat pump (CP2 = S8X1)COf = Demand for continuous fandFt = Demand for outdoor unit defrost, furnace running in gas heat modetP1-9 = Tap selected for airflow

Note:1. The menu status displayed is solely dependent on the input of 24VAC that is applied to the low voltage terminal strip.2. The status will alternate between the system mode and the airflow request every 2 seconds.3. If an error occures, an E*.* will alternately flash with the system mode and airflow request. See first example.

IInntteeggrraatteedd FFuurrnnaaccee CCoonnttrrooll MMeennuu

Page 58: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

58 18-CE04D1-1B-EN

Setting Airflow

With all ductwork connected and a clean filter in place, measure theExternal Static Pressure (ESP) of the unit in locations below. Use theappropriate airflow table for the furnace and outdoor unit installed.

Measurements must be made prior to the evaporator coil, if equipped,and after the filter.

EvaporatorCoil

Clean Filter

Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.)

Model Tap 0.1 0.3 0.5 0.7 0.9

S8X1B080M4PSAAS8X2B080M4PSAA

1 633 297 — — —

2 957 800 719 428 213

3 1220 1080 940 800 660

4 1403 1298 1192 1087 (a) 981

5 1524 1428 1336 1248 1164

6 1684 1574 1544 1401 1337

7 1700 1625 1551 1476 (b) 1401 (c)

8 1858 1790 1723 1656 1589

9 1967 1898 1829 1760 1691

(a) Exapmple 1, 2(b) Example 1(c) Example 2

Example 1: S8X2B080M4PSAAA (Default Tap 7)

Cooling / HP

• 3 Ton Single Stage Outdoor

• Total ESP = 0.7” W.C.

• Required Airflow = 1050 cfm (3T x 350 cfm/ton)

• New Tap Number = Tap 4

Example 2: S8X2B080M4PSAA (Default Tap 3 & 7)

• 4 Ton Two Stage Outdoor

• Total 2nd Stage ESP = 0.9” W.C.

• Total 1st Stage ESP = 0.6” W.C.

• Required 2nd Stage Airflow = 1400 cfm (4T x 350cfm/ton)

• Required 1st Stage Airflow = 1050 cfm (2nd stageairflow x .75)

• New 2nd Stage Tap Number = Tap 7 (no change)

• New 1st Stage Tap Number = Tap 4

Page 59: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 59

Integrated Furnace Control Display CodesMenu Options

IdL Idle

err Active Alarm Menu

L6F Last 6 Faults (To clear — Hold Option button down for 5 seconds after entering the L6Fmenu)

Cr Code Release Number

C0d Cooling Off Delay (Seconds)

0du Outdoor Unit Type (Single / Two Stage)

C0f Blower Constant Fan Airflow

Xod Heat Off Delay (Seconds)

!sd Inter-Stage Delay (Seconds)

gXC Gas Heating CFM (1st and 2nd stage airflow are selectable)

run Test Mode

Error Codes

Alarm Error Code Alarm Explanation

e0! Loss of the IRQ or other internal failures (Internal IFC error)

e2.! Retry Exceeded (Flame never sensed, one hour lockout after 3 times)

e2.2 Recycles Exceeded (Flame sensed then lost, one hour lockout after 10 times)

e2.3 1st Stage Gas Valve Not Energized When It Should Be exceeded after 10 times

e3.! Shorted Pressure Switch, 1st Stage

e3.2 Open Pressure Switch, 1st Stage

e3.3 Shorted Pressure Switch, 2nd Stage (S8X2 only)

e3.4 Open Pressure Switch, 2nd Stage (S8X2 only)

e04 Open Limit (Main Thermal, Rollout Switch, or Reverse Airflow Switch)

e0s Flame detected, should not be present

e6.! Voltage reversed polarity

e6.2 Bad grounding

e6.3

(1) Igniter relay fails

(2) Igniter open

e7.! 1st stage gas valve (MVL) is energized when it should be off

e08 Flame current is low, but still strong enough to allow operation

e11

(1) 1st stage gas valve not energized when it should be

(2) 1st stage gas valve relay stuck closed

(3) 2nd stage gas valve relay stuck closed

(4) 2nd stage gas valve energized when it should not be

(5) 2nd stage gas valve not energized when it should be

e12 Open fuse

Page 60: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

60 18-CE04D1-1B-EN

Fault Code RecoveryFault Code Recovery

1. To view the last 6 faults, press the “Menu” key until the “Last 6Faults” (L6F) menu appears.

2. Enter the menu by pressing the “Option” key.

3. The last 6 faults can be viewed.

Clearing the Last 6 Faults

1. To clear the last 6 faults, press the “Menu” key until the “Last 6Faults” (L6F) menu appears.

2. Enter the menu by pressing the “Option” key.

3. Hold the “Option” key for at least 5 seconds.

4. Release and a set of 3 dashes with be seen 3 times. This confirmsthe faults have been cleared.

Resetting Factory Defaults

1. Display must be in Idle Mode.

2. Push the “Menu” and “Option” buttons at the same time for 15seconds then release.

3. The 7 segment will flash “FD” 3 times. This confirms the unit hasbeen reset to the factory defaults.

Low Voltage Terminal Strip

10 Pin Connector (ILI not used)

LINEConnections

EAC, HUMDry Contacts

NeutralConnections

7 Segment LED

MENU and OPTIONSelect Buttons

5 Amp Fuse

Flame CurrentFP

HLI

W R G B/C Y2Y/Y1

Inducer/Igniter Connector

IGN-N

IND-N

IND-H

IGN-H

MV

GND

TH

MVC

HLO

PS1

TR

ILI

6 Pin CTM Motor ConnectorTap 1 - Low SpeedTap 2Tap 3Tap 4Tap 5 - High SpeedCommon

6 Pin CTM Connector

S8X1 IFC Component Layout

Low Voltage Terminal Strip

12 Pin Connector(ILI not used)

LINEConnections

EAC, HUMDry Contacts

NeutralConnections

Inducer/Igniter Connector

7 Segment LED

MENU and OPTIONSelect Buttons

5 Amp Fuse

Flame Current

FP

HLI

IGN-N

BK W2 W1 R G B/C Y2 Y1 O

IND-N

IND-LO

IND-HI

IGN-H

MVH

MVL

GND

PS2

TH

MVC

HLO

PS1

TR

ILI

6 Pin CTM Motor ConnectorTap 1 - Low SpeedTap 2Tap 3Tap 4Tap 5 - High SpeedCommon

6 Pin CTM Connector

S8X2 IFC Component Layout

IInntteeggrraatteedd FFuurrnnaaccee CCoonnttrrooll DDiissppllaayy CCooddeess

Page 61: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 61

Sequence of Operation S8X1/S8X2

NNoottee:: The seven-segment LED readout is based onthermostat input. For the S8X2, duringsimultaneous call for W1 and W2, the seven-segment LED will read “Xt2”, although the IFCwill process the call for 1st stage heat first.

EEAACC aanndd HHUUMM TTiimmiinngg

• EAC relay closes approximately 2 seconds after theblower starts.

• EAC relay opens when the blower motor stops.

• HUM relay closes on any heating call (HP/Gas)approximately 1 second after the blower motorstarts.

• HUM relay opens when any heating call (HP/Gas) isremoved.

11sstt SSttaaggee GGaass HHeeaattiinngg

1. R – W1 contacts close on the thermostat sending24VAC to the W1 low voltage terminal of the IFC.Technician should read 24VAC from W1 to B/C. Theseven segment LED will read: .

• Xt = S8X1• Xt1 = S8X22. The IFC performs a self-check routine and then

confirms:a. Flame roll-out switches (FRS) 1 & 2, main

thermal limit (TCO), and any reverse air flow(RAF) switches are closed by sending 24VAC outthe HLO terminal and monitoring the HLI input.

b. Pressure switch 1 (PS1) and pressure switch 2(PS2–S8X2 only) are opened by sending 24VACout the HLO terminal, through the limitswitches, and monitoring the PS1 (3) and PS2(7) inputs.

NNoottee:: If a thermal limit is open, 24VAC will notbe present at either pressure switch.

3. After steps a & b are confirmed, the inducer relay isclosed, energizing the inducer motor.

4. As the inducer ramps up, PS1 will close.

NNoottee:: S8X2 units will start the inducer motor on highspeed for approximately 6 seconds, then switchto low speed. If PS1 does not close within 60seconds, the control will report a e3.1 error andincrease the inducer to high speed in an attemptto close PS1.

5. When PS1 closes, the ignitor relay on the IFC willclose. The ignitor is energized. The ignitor warm upis approximately 17 seconds.

6. After the ignitor warm up, the 1 st stage gas valverelay is closed, which energizes the 1st stage gasvalve solenoid to allow ignition.

7. The first burner will ignite, and flame will crossoverto the remaining burners establishing current to theflame sensor. Flame sensing must be establishedwithin 4 seconds.

NNoottee:: There are two flame sense pads located on theIFC marked as “FP”. To measure the flamecurrent, use a VOM set to DC volts. 1VDC = 1micro-amp. Flame current will vary dependingon the type of meter used. Typical flame currentranges from 0.75 – 3.0 micro-amps (0.75 – 3 VDC).

8. Once the flame sense has been established, a timeron the IFC starts and the indoor blower will energizeat 1st stage speed after the blower “Heat On Delay”has completed. The seven-segment LED forexample will alternately read:

• Xt = Gas heating = S8X1• Xt1= Gas heating, stage 1 = S8X2• tP3= Tap 39. When the temperature raises enough to satisfy the

thermostat setting, contacts R-W1 will open.10. The gas valve relay will open, closing the gas valve.

The inducer will continue to run for approximately 5seconds to remove any combustion byproductsfrom inside the furnace.

11. The indoor blower continues to run to remove heatfrom the heat exchangers. The “blower off” time isfield adjustable through the IFC menu setup option.The seven-segment LED will read “IDL” = Idle, nothermostat demand.

22nndd SSttaaggee GGaass HHeeaattiinngg ((SS88XX22 OOnnllyy))

1. See sequence of operation for 1st stage gas heatingoperation above (steps 1–7)

NNoottee:: 2nd stage heating cannot operate without 1ststage operation.

2. R-W2 contacts close on the thermostat sending24VAC from to the W2 low voltage terminal of theIFC. Technician should read 24VAC from W2 to B/C.The seven-segment LED will read Ht2.

3. The IFC checks to ensure that PS2 is open, and thenenergizes the 2nd stage inducer relay. The induceris energized on high speed, and the second stagegas valve relay on the IFC closes, energizing secondstage gas valve. The indoor blower motor will rampup to the 2nd stage gas heating speed. The seven-segment LED for example will alternately read:

• Xt2 = Gas heating = stage 2• tP5= Tap 54. The IFC monitors PS2 for closure and if PS2 does

not close within 45 seconds, a PS2 open error willbe declared and the furnace will operate in 1st

stage. If PS2 closes, 2nd stage gas heating willcontinue until the thermostat R-W2 contacts open.

Page 62: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

62 18-CE04D1-1B-EN

NNoottee:: If PS2 does not close within the 45 seconds, theIFC will wait 10 minutes and repeat steps 3 & 4. Ifon the third attempt during the same heating call,PS2 does not close within the 45 second provingtime, the unit will run in 1st stage until thethermostat R-W2 contacts open.

5. When the temperature raises enough to satisfy thethermostat setting, contacts R-W2 will open, the 2nd

stage gas valve will close, the indoor blower motorwill ramp down to 1st stage, and the unit willcontinue to run until R-W1 contacts open.

6. When the temperature raises enough to satisfy thethermostat setting, contacts R-W1 will open.

7. The gas valve relay will open, closing the gas valve.The inducer will continue to run for approximately 5seconds to remove any combustion byproductsfrom inside the furnace.

8. The indoor blower continues to run to remove heatfrom the heat exchangers. This blower off time isfield adjustable through the IFC menu setup option.The seven-segment LED will read 1DL = Idle, nothermostat demand.

SSiinnggllee SSttaaggee CCoooolliinngg

1. R-Y1-G contacts on the thermostat close sending24VAC to the Y1 and G low voltage terminals on theIFC. Technician should read 24VAC between Y1-B/Cand between G-B/C.

NNoottee:: For S8X2 units, the factory supplied Y1-Ojumper must remain in place for properseven-segment LED readout, and furnaceoperation. If removed, the seven-segmentLED will read “HP1”.

2. 24VAC is sent to the OD unit via thermostat wiring.3. The indoor blower ramps to the cooling airflow.

The seven-segment LED for example willalternately read:

• CL1 = Cooling, Stage 1 (S8X2)• CP1 = Cooling, Stage 1 (S8X1)• tP3 = Tap 34. When the temperature is lowered enough to satisfy

the thermostat setting, contacts R-Y-G will open.5. The OD unit shuts off and the indoor blower shuts

off, unless a blower “Cool Off Delay” has beenenabled in the IFC setup menu options. The seven-segment LED will read “IDL” = Idle, no thermostatdemand.

TTwwoo SSttaaggee CCoooolliinngg

1. See sequence of operation for Single stage coolingoperation above (steps 1–3)

2. R-Y2 contact on the thermostat close sending24VAC to Y2 low voltage terminal on the IFC.Technician should read 24VAC between Y2 and B/C.

3. 24VAC is sent to the OD unit via thermostat wiring.4. The indoor airflow ramps to 2nd stage airflow. The

seven-segment LED for example will read:

• CL2 = Cooling, Stage 2 (S8X2)• CP2 = Cooling, Stage 2 (S8X1)• tP7 = Tap 75. When the temperature is lowered enough to satisfy

the thermostat setting, contacts R-Y1-Y2-G willopen.

6. The OD unit shuts off and the indoor blower shutsoff, unless a blower “Cool Off Delay” has beenenabled in the IFC setup menu options. The seven-segment LED will read 1DL = Idle, no thermostatdemand.

SSiinnggllee SSttaaggee HHeeaatt PPuummpp

1. R-Y1-G contacts on the thermostat close sending24VAC to the Y1 and G low voltage terminals on theIFC. Technician should read 24VAC between Y1-B/Cand between G-B/C.

NNoottee:: For S8X2 units, the factory supplied Y1-Ojumper must be removed for properseven-segment LED readout and furnaceoperation. If left in place, the seven-segment LED will read CL1

2. 24 VAC is sent to the OD unit via thermostat wiring.3. The indoor blower ramps to the cooling airflow.

The seven-segment LED for example willalternately read:

• HP1 = Cooling, Stage 1 (S8X2)• CP1 = Cooling, Stage 1 (S8X1)• tP3 = Tap 34. When the temperature is lowered enough to satisfy

the thermostat setting, contacts R-Y-G will open.5. The OD unit shuts off and the indoor blower shuts

off, unless a “Cool Off Delay” has been enabled inthe IFC setup menu options. The seven-segmentLED will read 1DL = Idle, no thermostat demand.

TTwwoo SSttaaggee HHeeaatt PPuummpp

1. See sequence of operation for single stage coolingoperations above (steps 1–3).

2. R-Y2 contact on the thermostat close sending24VAC to Y2 low voltage terminal on the IFC.Technician should read 24VAC between Y2 and B/C.

3. 24VAC is sent to the OD unit via thermostat wiring.4. The indoor airflow ramps to 2nd stage airflow. The

seven-segment LED for example will read:

• HP2 = Cooling, Stage 2 (S8X2)• CP2 = Cooling, Stage 2 (S8X1)• tP7 = Tap 75. When the temperature is raised enough to satisfy

the thermostat setting, contacts R-Y1-Y2-G willopen.

6. The OD unit shuts off and the indoor blower shutsoff, unless a “Blower Off Delay” has been enabledin the IFC setup menu options. The seven-segmentLED will read 1dL = Idle, no thermostat demand.

SSeeqquueennccee ooff OOppeerraattiioonn SS88XX11//SS88XX22

Page 63: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

18-CE04D1-1B-EN 63

NNootteess

Page 64: Installer's Guide - Upflow/Horizontal Left/Right, Downflow

Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficientenvironments. Our people and our family of brands — including Club Car®, Ingersoll Rand®, Thermo King® andTrane® —work together to enhance the quality and comfort of air in homes and buildings; transport and protectfood and perishables; and increase industrial productivity and efficiency. We are a global business committed to aworld of sustainable progress and enduring results.

ingersollrand.com

Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specificationswithout notice.We are committed to using environmentally conscious print practices.

18-CE04D1-1B-EN 15 Jan 2019

Supersedes 18-CE04D1-1A-EN (May 2018) ©2018 Ingersoll Rand