XL 90TUX2B060A9362A, TUX2B080A9422A,TUX2C100A9482A, TUX2D120A9602A,TDX2B060A9362A, TDX2B080A9422A,TDX2C100A9482A, TDX2D120A9602ADirect Vent withVariable Speed Inducer

PUB. NO. 22-1705-08

Upflow/ Horizontal Left,Downflow/ Horizontal RightTwo Stage CondensingGas-Fired Furnace

2 Pub. No. 22-1705-08

GeneralFeatures

© 2011 Trane All Rights Reserved

NATURAL GAS MODELSCentral Heating furnace designs arecertified by the American Gas Associa-tion for both natural and L.P. gas. Limitsetting and rating data were estab-lished and approved under standardrating conditions using American Na-tional Standards Institute standards.

SAFE OPERATIONThe Integrated System Control hassolid state devices, which continuouslymonitor for presence of flame, whenthe system is in the heating mode ofoperation. Dual solenoid combinationgas valve and regulator provide extrasafety.

QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to in-crease efficiency and provide apositive discharge of gas fumes to theoutside.

BURNERSMultiport Inshot burners will give yearsof quiet and efficient service. All mod-els can be converted to L.P. gaswithout changing burners.

INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnacelimit sensors, blowers, gas valve,flame control and includes self diag-nostics for ease of service. Alsocontains connection points for E.A.C./Humidifier.

AIR DELIVERYThe four speed, direct drive blower mo-tor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speedson demand from room thermostat. Theblower door safety switch will preventor terminate furnace operation whenthe blower door is removed.

STYLINGHeavy gauge steel and “wrap-around” cabinet construction isused in the cabinet with baked-onenamel finish for strength and beauty.The heat exchanger section of the cab-inet is completely lined with foil facedfiberglass insulation. This results inquiet and efficient operation due to theexcellent acoustical and insulatingqualities of fiberglass. Built-in bottompan and alternate bottom, left or rightside return air connection provision.

FEATURES AND GENERALOPERATIONThe XL90 High Efficiency Gas Furnac-es employ an Adaptive Heat Up SiliconNitride Hot Surface Ignition system,which eliminates the waste of a con-stant burning pilot. The integratedsystem control lights the main burnersupon a demand for heat from the roomthermostat. Complete front service ac-cess.a. Low energy power venterb. Vent proving pressure switch.

3Pub. No. 22-1705-08

Contents

General FeaturesFeatures and Benefits

Standard Equipment

Optional Equipment

General Data TUX2B060A9362ATUX2B080A9422ATUX2C100A9482ATUX2D120A9602ATDX2B060A9362ATDX2B080A9422ATDX2C100A9482ATDX2D120A9602A

Performance Data

Venting Tables

Electrical Data

Field Wiring

Twinning Field Wiring

Dimensions

2445

6-7

8-9 10-11

12-13

14-15

16-17

18-19

4 Pub. No. 22-1705-08

XL 90 STANDARD EQUIPMENT

Featuresand Benefits

• HInged blower door *

• Perfect fit door latches*

• Insulated blower door*

• Gasketed blower door*

• Internal filter rack*

• Standard filter sizes• Two tone color• Multi-port In-shot burners• Complete front service access• Left/right gas connection• Adjustable fan off times• Optional L.P conversion kit• Selectable cooling fan off delay elimi-

nates need for BAY24X045time delay kit

• Direct Drive - 4 speed PSC Motor• Silicon Nitride Igniter with adaptive heat

up• Variable speed induced draft blower• Direct/Non-Direct vent option• Fused 24 volt control circuit• Manual reset burner safety switches• Power supply 115/1/60• Convertible to horizontal on left side• 2-stage gas valve• PVC venting-1 or 2 pipe option• Accessory hook-up capability• Integrated solid state control with

self-diagnostics• Attractive color accents• Heavy gauge aluminized steel heat

exchanger• Multi-port In-shot burners• Single wire twinning

* (Upflow only)

5Pub. No. 22-1705-08

Featuresand Benefits

XL 90 OPTIONAL EQUIPMENT

Thermostat, 2-Stage Heat / 1-Stage Cooling ............................................................................................... TAYSTAT241 [ ]Thermostat, Electronic Programmable 2-Stage Heating ............................................................................TAYSTAT302C [ ]Thermostat, Mechanical Heating Only With Fan Switch ............................................................................TAYSTAT303C [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ....................................................................AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................... BAYSTAT305 [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ..................................................TAYSTAT300C [ ]Propane Conversion Kit ........................................................................................................................... BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) ........................................ TFM145A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ....................................... TFM175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ............................................. TFM210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ....................................... TFM245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ................................. TFP145A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ................................. TFP175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ....................................... TFP210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ................................. TFP245A9FR0 [ ]Coil Enclosure (14-1/2" Wide Cabinets) ..............................................................................................BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ..............................................................................................BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) ....................................................................................................BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ..............................................................................................BAYCLE24A2430A [ ]Downflow Subbase .....................................................................................................................................BAYBASE205 [ ]Side Filter Rack ........................................................................................................................................... BAYFLTR200 [ ]Filter Kit/Horizontal Conversion TUX060,080-R........................................................................................... BAYFLTR203 [ ]Filter Kit/Horizontal Conversion TUX100-R ................................................................................................. BAYFLTR204 [ ]Filter Kit/Horizontal Conversion TUX120-R ................................................................................................. BAYFLTR205 [ ]Filter Accessory Kit .................................................................................................................................... BAYFLTR317 [ ]Filter Accessory Kit .................................................................................................................................... BAYFLTR321 [ ]Filter Accessory Kit .................................................................................................................................... BAYFLTR324 [ ]High Altitude Pressure Switch Kit (TUX2B060, TDX2B060) ................................................................... BAYHALT2451 [ ]High Altitude Pressure Switch Kit (TUX2B080, TUX2C100, TDX2B080, TDX2C100) ............................. BAYHALT2461 [ ]High Altitude Pressure Switch Kit (TUX2D120, TDX2D120) ................................................................... BAYHALT2471 [ ]Concentric Vent Kit TUX Furnaces ......................................................................................................... BAYVENT100A [ ]Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces ............................................................... BAYVENT200B [ ]Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces .......................................................... BAYMFGH100A [ ]Filter Rack Kit ......................................................................................................................................... BAYRACK960A [ ]Cleanable Filter (14.5"/17.5" wide Upflow models) ...................................................................................... BAYFLTR317 [ ]Cleanable Filter (21" wide Upflow models) .................................................................................................. BAYFLTR321 [ ]Cleanable Filter (24.5" wide Upflow models) ............................................................................................... BAYFLTR324 [ ]1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.

6 Pub. No. 22-1705-08

GeneralData

1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

MODEL

RATINGS21st Stage Input BTUH

1st Stage Capacity BTUH (ICS)32nd Stage Input BTUH

2nd Stage Capacity BTUH (ICS)3AFUE (ICS)Temp. Rise (Min.-Max.) °F.

BLOWER DRIVEDia.-Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts/Ph/Hz

COMBUSTION FAN - TYPEDrive - No. SpeedsMotor HP - RPMVolts/Ph/HzFL Amps

FILTER — Furnished?Type RecommendedFilter (No.-Size-Thk.)

VENT — Size (In.)

HEAT EXCHANGERType -Fired

-UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

DIRECT IGNITION DEVICEType

BURNERS — TypeNumber

POWER CONN. — V/Ph/Hz4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DUCT CONN.

DIMENSIONSCrated (In.)Uncrated

WEIGHTShipping (Lbs.)/Net (Lbs.)

TUX2 PRODUCT SPECIFICATIONS1

TUX2B060A9362A

3900036000600005600093.0

30 - 60DIRECT10 x 7

14

SEE FAN PERF. TABLE1/3

1075115/1/60

CENTRIFUGALDIRECT - VARIABLE

1/15 - 500033 - 110/3/60 - 180

1.0NO

HIGH VELOCITY1 - 17 X 25 - 1 IN

2 ROUND

ALUMINIZED STEEL TYPE 1

20

3 - 453 - 56

REDUNDANT - TWO STAGE

HOT SURFACEIN-SHOT

3115/1/60

8.7151/2

SEE OUTLINE DRAWINGH X W X D

41-3/4 X 19-1/2 X 30-1/2SEE OUTLINE DRAWING

158 / 146

TUX2B080A9422A

5200048000800007300092.5

35 - 65DIRECT10 x 8

14

SEE FAN PERF. TABLE1/3

1075115/1/60

CENTRIFUGALDIRECT - 1

1/15 - 500033 - 110/3/60 - 180

1.0NO

HIGH VELOCITY1 - 17 X 25 - 1 IN

2 ROUND

ALUMINIZED STEEL TYPE 1

20

4 - 454 - 56

REDUNDANT - TWO STAGE

HOT SURFACEIN-SHOT

4115/1/60

9.5151/2

SEE OUTLINE DRAWINGH X W X D

41-3/4 X 19-1/2 X 30-1/2SEE OUTLINE DRAWING

168 / 156

TUX2C100A9482A

6500060000

1000009300093.0

35 - 65DIRECT10 x 10

14

SEE FAN PERF. TABLE1/2

1075115/1/60

CENTRIFUGALDIRECT - VARIABLE

1/15 - 500033 - 110/3/60 - 180

1.0NO

HIGH VELOCITY1 - 20 X 25 - 1 IN

2 ROUND

ALUMINIZED STEEL TYPE 1

20

5 - 455 - 56

REDUNDANT - TWO STAGE

HOT SURFACEIN-SHOT

5115/1/60

13.1201/2

SEE OUTLINE DRAWINGH X W X D

41-3/4 X 23 X 30-1/2SEE OUTLINE DRAWING

197 / 185

TUX2D120A9602A

7200066600

120000112000

92.540 - 70DIRECT11 x 10

14

SEE FAN PERF. TABLE3/4

1100115/1/60

CENTRIFUGALDIRECT - VARIABLE

1/15 - 500033 - 110/3/60 - 180

1.0NO

HIGH VELOCITY1 - 24 X 25 - 1 IN

3 ROUND

ALUMINIZED STEEL TYPE 1

20

6 - 456 - 56

REDUNDANT - TWO STAGE

HOT SURFACEIN-SHOT

6115/1/60

13.5201/2

SEE OUTLINE DRAWINGH X W X D

41-3/4 X 26-1/2 X 30-1/2SEE OUTLINE DRAWING

206 / 193

7Pub. No. 22-1705-08

MODEL

RATINGS21st Stage Input BTUH

1st Stage Capacity BTUH (ICS)32nd Stage Input BTUH

2nd Stage Capacity BTUH (ICS)3AFUE (ICS)Temp. Rise (Min.-Max.) °F.

BLOWER DRIVEDia.-Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts/Ph/Hz

COMBUSTION FAN - TYPEDrive - No. SpeedsMotor HP - RPMVolts/Ph/HzFL Amps

FILTER — Furnished?Type RecommendedFilter (No.-Size-Thk.)

VENT — Size (In.)

HEAT EXCHANGERType -Fired

-UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

DIRECT IGNITION DEVICEType

BURNERS — TypeNumber

POWER CONN. — V/Ph/Hz4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DUCT CONN.

DIMENSIONSCrated (In.)Uncrated

WEIGHTShipping (Lbs.)/Net (Lbs.)

GeneralData

TDX2 PRODUCT SPECIFICATIONS1

1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

TDX2B080A9422ATDX2B080A9422ATDX2B080A9422ATDX2B080A9422ATDX2B080A9422A

5200048000800007400092.5

40 - 70DIRECT11 x 8

14

SEE FAN PERF. TABLE1/2

1075115/1/60

CENTRIFUGALDIRECT - VARIABLE

1/15 - 500033 - 110/3/60 - 180

1.0NO

HIGH VELOCITY2 - 14 X 20 X 1

2 ROUND

ALUMINIZED STEEL TYPE 1

20

4 - 454 - 56

REDUNDANT - TWO STAGE

HOT SURFACE IGNITERIN-SHOT

4115/1/60

11.315

0.50SEE OUTLINE DRAWING

H X W X D41-3/4 X 19-1/2 X 30-1/2SEE OUTLINE DRAWING

168 / 158

TDX2B060A9362ATDX2B060A9362ATDX2B060A9362ATDX2B060A9362ATDX2B060A9362A

3900036000600005500092.0

35 - 65DIRECT10 x 8

14

SEE FAN PERF. TABLE1/3

1075115/1/60

CENTRIFUGALDIRECT - VARIABLE

1/15 - 500033 - 110/3/60 - 180

1.0NO

HIGH VELOCITY2 - 14 X 20 X 1

2 ROUND

ALUMINIZED STEEL TYPE 1

20

3 - 453 - 56

REDUNDANT - TWO STAGE

HOT SURFACE IGNITERIN-SHOT

3115/1/60

9.515

0.50SEE OUTLINE DRAWING

H X W X D41-3/4 X 19-1/2 X 30-1/2SEE OUTLINE DRAWING

160 / 145

TDX2C100A9482ATDX2C100A9482ATDX2C100A9482ATDX2C100A9482ATDX2C100A9482A

6500060000

1000009300093.0

45 - 75DIRECT11 x 10

14

SEE FAN PERF. TABLE1/2

1075115/1/60

CENTRIFUGALDIRECT - VARIABLE

1/15 - 500033 - 110/3/60 - 180

1.0NO

HIGH VELOCITY2 - 16 X 20 X 1

2 ROUND

ALUMINIZED STEEL TYPE 1

20

5 - 455 - 56

REDUNDANT - TWO STAGE

HOT SURFACE IGNITERIN-SHOT

5115/1/60

13.120

0.50SEE OUTLINE DRAWING

H X W X D41-3/4 X 23 X 30-1/2

SEE OUTLINE DRAWING

185 / 175

TDX2D120A9602ATDX2D120A9602ATDX2D120A9602ATDX2D120A9602ATDX2D120A9602A

7800072000

120000111000

92.545 - 75DIRECT11 x 10

14

SEE FAN PERF. TABLE3/4

1075115/1/60

CENTRIFUGALDIRECT - VARIABLE

1/15 - 500033 - 110/3/60 - 180

1.0NO

HIGH VELOCITY2 - 16 X 20 X 1

3 ROUND

ALUMINIZED STEEL TYPE 1

20

6 - 456 - 56

REDUNDANT - TWO STAGE

HOT SURFACE IGNITERIN-SHOT

6115/1/60

13.520

0.50SEE OUTLINE DRAWING

H X W X D41-3/4 X 26-1/2 X 30-1/2SEE OUTLINE DRAWING

206 / 196

8 Pub. No. 22-1705-08

FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)

MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90

*UX2B060A9362A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

139412501102957

135912321092944

131412021069922

126011601034891

11961106986853

11221040925806

1038962852750

945873766686

853771668614

*UX2B080A9422A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

174813751178859

168313671167863

161513471147856

154413141119839

147012681082811

139312101036772

13141139982723

12321056919663

1147960847592

*UX2C100A9482A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2054193217621558

1980187517201546

1906181816771533

1826174616151477

1746167315521421

1649157714631350

1551148113731278

1428137112661175

1305126011581071

*UX2D120A9602A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2454210517471445

2406209217421447

2358207817361449

2310204517201440

2261201217031430

2184195016771400

2106188716511369

2017182615931325

1928176515351280

* - First letter may be "A" or "T"

NOTE: See page 11 for factory heat & cool speed tap settings

CFM VS. TEMPERATURE RISE

MODELCubic Feet Per Minute (CFM)

900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200

*UX2B060A9362A 56 50 45 42 39 36

*UX2B080A9422A 61 56 51 48 44 42

*UX2C100A9482A 64 60 56 52 49 46 44 42

*UX2D120A9602A 63 59 56 53 50 48 46

* - First letter may be "A" or "T"

UpflowPerformance Data

9Pub. No. 22-1705-08

FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)

MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90

*DX2B060A9362A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

148713421181877

142512911147863

136212401113849

128611821061820

120911241009791

11251047943739

1040989877686

935869779612

830769681537

*DX2B080A9422A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1547148713881263

1498143613481234

1445138213021196

1386132512491150

1323126511911095

1254120211261032

118011371056960

11011069979879

1016998896790

*DX2C100A9482A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1892177916301444

1827172615871416

1762167215441388

1688160514851348

1614153814261308

1531146013621246

1448138112971184

1354129112081108

1260120011191032

*DX2D120A9602A

4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2213205717651468

2138200017331452

2062194317001435

2001188316521409

1939182216031382

1863175215521336

1786168115001290

1706159514241225

1625150813471159

*- First letter may be "A" or "T"

CFM VS. TEMPERATURE RISE

MODELCubic Feet Per Minute (CFM)

800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400

*DX2B060A9362A 63 56 51 46 42 39 36 34

*DX2B080A9422A 68 61 56 52 48 45 42 40

*DX2C100A9482A 65 60 56 53 50 47 44 42 40 38 37 35

*DX2D120A9602A 67 63 59 56 53 51 48 46 44 42

*- First letter may be "A" or "T"

DownflowPerformance Data

10 Pub. No. 22-1705-08

Maximum VentLength Table

VENT LENGTH TABLE

ALTITUDEMAXIMUM TOTAL EQUIVALENT LENGTH IN FEET

FOR VENT AND INLET AIR (SEE NOTES)

0-7,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH* PIPE

*UX/ *DX2B060A9362A 200 200 200

*UX/ *DX2B080A9422A 50 120 200

*UX/ *DX2C100A9482A Not Allowed 60 200

*UX/ *DX2D120A9602A Not Allowed Not Allowed 200

7,000-9,500 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE

*UX/ *DX2B060A9362A 100 100 100

*UX/ *DX2B080A9422A 25 60 100

*UX/ *DX2C100A9482A Not Allowed 30 100

*UX/ *DX2D120A9602A Not Allowed Not Allowed 100

9,500-12,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE

*UX/ *DX2B060A9362A 50 50 50

*UX/ *DX2B080A9422A Not Allowed 30 50

*UX/ *DX2C100A9482A Not Allowed Not Allowed 50

*UX/ *DX2D120A9602A Not Allowed Not Allowed 50

NOTES: * - First letter may be "A" or "T"1. Minimum vent length for all models: 3' horizontal and vertical.2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET (Exceptadapters at the top of the furnace). If different inlet and vent pipe sizes are used, the vent pipe must adhere to themaximum length limit shown in the table above (See note 6 below for exception). The inlet pipe can be of a largerdiameter, but never smaller than the vent pipe.3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT ISTHE MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes).4. One SHORT radius 90° elbow is equivalent to 10' of 3" pipe and one LONG radius elbow is equivalent to 6' of 3" pipe.One 90° elbow is equivalent to 7½' of 2½" pipe or 5' of 2" pipe. Two 45° elbows equal one 90°elbow.5. The termination tee or bend must be included in the total number of elbows. If the BAYAIR30AVENTA termination kitis used, the equivalent length of pipe is 5 feet. BAYVENT200B equivalent length is 0 feet.6. Pipe adapters are field supplied (except 120).

11Pub. No. 22-1705-08

ElectricalData

*UX2 WIRING DIAGRAM

From Dwg. D342781P01

12 Pub. No. 22-1705-08

ElectricalData

From Dwg. D342782P01

*UX2 SCHEMATIC DIAGRAM

13Pub. No. 22-1705-08

*DX2 WIRING DIAGRAM

14 Pub. No. 22-1705-08

*DX2 SCHEMATIC DIAGRAM

15Pub. No. 22-1705-08

FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY

FIELD WIRING DIAGRAM FOR TWO STAGE HEATING ONLY

FieldWiring

16 Pub. No. 22-1705-08

FieldWiring

FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)

FIELD WIRING DIAGRAM FOR TWO STAGE HEATING/ SINGLE STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)

17Pub. No. 22-1705-08

Twinning FieldWiring

18 Pub. No. 22-1705-08

Twinning FieldWiring

19Pub. No. 22-1705-08

Dimensions

Fro

m D

wg.

21C

3418

84 R

ev. 1

*UX

2 U

PFL

OW

/HO

RIZ

ON

TAL

OU

TLIN

E D

RA

WIN

G(A

LL D

IME

NS

ION

S A

RE

IN IN

CH

ES

)

Mo

del

(See

No

te 1

& 2

)D

IM "

A"

DIM

"B

"D

IM "

C"

DIM

"D

"D

IM "

E"

DIM

"F

"

*UX

2B06

0A93

62A

*UX

2B08

0A94

22A

17-1

/2"

2-1/

4"16

-1/4

"16

"7-

1/2"

2"

*UX

2C10

0A94

82A

21"

2-1/

2"19

-3/4

"19

-1/2

"9"

3"

*UX

2D12

0A96

02A

24-1

/2"

2-15

/16"

23-1

/4"

23"

10"

3"

* P

refix

May

Be

"A"

or "

T"

Not

es:

1. *

UX

2D12

0A96

02A

Req

uire

s 3"

Dia

met

er V

ent P

ipe.

*UX

2C10

0A94

82A

R

equi

res

2-1/

2" o

r 3"

Dia

met

er V

ent

Pip

e.2.

Dia

met

er o

f Ven

t PIp

e m

ay b

e lim

ited

to 2

-1/2

" or

3"

on s

ome

mod

els

at d

iffer

ent a

ltitu

des.

Ref

er to

the

Ven

t Len

gth

Tabl

e fo

rpr

oper

app

licat

ion.

20 Pub. No. 22-1705-08

Fro

m D

wg.

21C

3418

85 R

ev. 1

*DX

2 D

OW

NFL

OW

/HO

RIZ

ON

TAL

OU

TLIN

E D

RA

WIN

G(A

LL D

IME

NS

ION

S A

RE

IN IN

CH

ES

)

Mo

del

(See

No

te 1

)D

IM "

A"

DIM

"B

"D

IM "

C"

DIM

"D

"

*DX

2B06

0A93

62A

*DX

2B08

0A94

22A

17-1

/2"

2-1/

4"16

-1/4

"16

"

*DX

2C10

0A94

82A

21"

2-1/

2"19

-3/4

"19

-1/2

"

*DX

2D12

0A96

02A

24-1

/2"

2-15

/16"

23-1

/4"

23"

* P

refix

May

Be

"A"

or "

T"

Not

es:

1. D

iam

eter

of

Ven

t P

ipe

may

be

limite

dto

2-1

/2"

or 3

" on

som

e m

odel

s at

diffe

rent

alti

tude

s. R

efer

to

the

Ven

tLe

ngth

Tab

le fo

r p

rope

r ap

plic

atio

n.

21Pub. No. 22-1705-08

Notes

Since Trane has a policy of continuous product and product data improvement, it reserves the right tochange design and specifications without notice.

Trane6200 Troup HighwayTyler, TX 75707www.trane.com