  • Upflow/ HorizontalDownflow/HorizontalCondensing, Direct VentGas-Fired Furnace

    PUB. NO. 22-1836-07

    XR 95TUH1B040A9241A, TUH1B060A9361A,TUH1B080A9421A, TUH1C080A9601A,TUH1C100A9481A, TUH1D100A9601A,TUH1D120A9601A, TDH1B040A9241A,TDH1B065A9421A, TDH1C085A9481A,TDH1D110A9601A

    Single-Stage Fan AssistedCombustion System

    *DH1DOWNFLOW

    DOWNFLOW/HORIZONTAL

    *UH1UPFLOW

    *UH1UPFLOW/HORIZONTAL

    *DH1

  • 2011 Trane All Rights Reserved 2 22-1836-07

    GeneralFeatures

    NATURAL GAS MODELSCentral Heating furnace designs arecertified to ANSI Z21.47 / CSA 2.3 forboth natural and L.P. gas. Limit settingand rating data were established andapproved under standard rating condi-tions using American National StandardsInstitute standards.

    SAFE OPERATIONThe Integrated System Control has solidstate devices, which continuously monitorfor presence of flame, when the system isin the heating mode of operation. Dualsolenoid combination gas valve andregulator provide extra safety.

    QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to increaseefficiency and provide a positive dis-charge of gas fumes to the outside.

    BURNERSMultiport Inshot burners will give years ofquiet and efficient service. All modelscan be converted to L.P. gas withoutchanging burners.

    INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self diagnostics forease of service. Also contains connec-tion points for E.A.C./humidifier.

    AIR DELIVERYThe four speed, direct drive blowermotor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speeds ondemand from room thermostat. Theblower door safety switch will prevent orterminate furnace operation when theblower door is removed.

    STYLINGHeavy gauge steel and wrap-aroundcabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heat ex-changer section of the cabinet is com-pletely lined with foil faced fiberglassinsulation. This results in quiet andefficient operation due to the excellentacoustical and insulating qualities offiberglass. Built-in bottom pan andalternate bottom, left or right side returnair connection provision.

    FEATURES ANDGENERAL OPERATIONThe XR 95 High Efficiency Gas Furnacesemploy a Silicon Nitride Hot SurfaceIgnition system, which eliminates thewaste of a constant burning pilot. Theintegrated system control lights the mainburners upon a demand for heat from theroom thermostat. Complete front serviceaccess.

    a. Low energy power venter

    b. Vent proving pressure switch.

    Featuresand Benefits

    XR 95 Standard Equipment Power supply 115/1/60

    Convertible to horizontal

    Type 29-4C stainless steel second-ary heat exchanger

    Inner blower doors

    Direct drive, 4-speed motors

    Silicon Nitride igniter with adaptiveheat up

    Accessory hook-up capability Hum and EAC

    Quiet induced draft blower

    Blower door safety switch

    Dual solenoid combination gas valve &regulator

    PVC venting 1 or 2 pipe vent option

    Left/right gas connection

    Selectable cooling fan off delayeliminates need for BAY24X045 timedelay relay

    Single wire twinning

    Integrated solid state control with self-diagnostics

    24 volt fuse

    Manual reset burner box limit

    Optional extended warranties

  • 22-1836-07 3

    Contents

    General Features 2

    Features and Benefits 2XR 95 Standard Equipment 2XR 95 Optional Equipment 4

    General Data 5TUH1B040A9241A 5TUH1B060A9361A 5TUH1B080A9421A 5TUH1C080A9601A 6TUH1C100A9481A 6TUH1D100A9601A 6TUH1D120A9601A 6TDH1B040A9241A 7TDH1B065A9421A 7TDH1C085A9481A 7TDH1D110A9601A 7

    Performance Data 8

    Electrical Data 10

    Field Wiring 14

    Twinning Field Wiring 15

    Dimensions 16

  • 4 22-1836-07

    Features andBenefits

    XR 95 Optional EquipmentComfort Control, XL803, Programmable 7 Day, 3-Ht, 2-Cl ........................................................................... TCONT803AS32DA [ ]Comfort Control, XR402, Electric, 3-Ht, 2-Cl (Non-programmable) .............................................................. TCONT402AN32DA [ ]For additional comfort control choices, see the product catalog or quick select handbookPropane Conversion Kit ....................................................................................................................................... BAYLPKT210B [ ]Propane Conversion Kit (stainless steel burners) ................................................................................................ BAYLPSS210B [ ]Downflow Subbase ................................................................................................................................................ BAYBASE205 [ ]Filter Access Door Kit .............................................................................................................................................. BAYFLTR206 [ ]Side Filter Rack ....................................................................................................................................................... BAYFLTR200 [ ]High Altitude Pressure Switch Kit TUH1B040, TDH1B040, TDH1C085 .........................................................BAYSWT01AHALTA [ ]High Altitude Pressure Switch Kit TUH1B060, TUH1D100, TUH1D120 .........................................................BAYSWT04AHALTA [ ]High Altitude Pressure Switch Kit TUH1B080, TUH1C100, TDH1D110 .........................................................BAYSWT05AHALTA [ ]High Altitude Pressure Switch Kit TUH1C080 ...............................................................................................BAYSWT11AHALTA [ ]High Altitude Pressure Switch Kit TDH1B065 ................................................................................................BAYSWT12AHALTA [ ]Concentric Vent Kit ......................................................................................................................................... BAYAIR30AVENTA [ ]Sidewall Vent Termination Kit .............................................................................................................................. BAYVENT200B [ ]Manufactured/Mobile Home Kit ...........................................................................................................................BAYMFGH100A [ ]

  • 22-1836-07 5

    Product Specifications 1MODEL

    TYPE

    RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) F.

    BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

    COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

    FILTER Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

    VENT PIPE DIAMETER Min (In.) 56

    HEAT EXCHANGERType-Fired

    -UnfiredGauge (Fired)

    ORIFICES MainNat. Gas. Qty. Drill SizeL.P. Gas Qty. Drill Size

    GAS VALVE

    PILOT SAFETY DEVICEType

    BURNERS TypeNumber

    POWER CONN. V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

    PIPE CONN. SIZE (IN.)

    DIMENSIONSCrated (In.)

    WEIGHTShipping (Lbs.) / Net (Lbs)

    GeneralData

    TUH1B040A9241A

    Upflow / Horizontal

    40,00038,00095.0

    30 - 60

    DIRECT9 x 7

    14

    See Fan Performance Table1/5

    1075115/1/60

    CentrifugalDirect - 1

    1/55 - 3000115/1/60

    1.0

    NoHigh Velocity

    1 - 17x25 - 1in.

    2 Round

    Aluminized Steel - Type I

    20

    2 452 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multiport Inshot2

    115/1/605.215

    1/2

    H x W x D41-3/4 x 19-1/2 x 30-1/2

    139 / 129

    TUH1B060A9361A

    Upflow / Horizontal

    60,00057,000

    95.030 - 60

    DIRECT10 x 7

    14

    See Fan Performance Table1/3

    1075115/1/60

    CentrifugalDirect - 1

    1/55 - 3450115/1/60

    1.75

    NoHigh Velocity

    1 - 17x25 - 1in.

    2 Round

    Aluminized Steel - Type I

    20

    3 453 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multiport Inshot3

    115/1/609.215

    1/2

    H x W x D41-3/4 x 19-1/2 x 30-1/2

    150 / 140

    Notes1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea

    level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feetabove sea level.

    3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".

    TUH1B080A9421A

    Upflow / Horizontal

    80,00076,00095.0

    35 - 65

    DIRECT11 x 8

    14

    See Fan Performance Table1/2

    1075115/1/60

    CentrifugalDirect - 1

    1/24 - 3450115/1/60

    0.71

    NoHigh Velocity

    1 - 17x25 - 1in.

    3 Round

    Aluminized Steel - Type I

    20

    4 454 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multiport Inshot4

    115/1/6010.215

    1/2

    H x W x D41-3/4 x 19-1/2 x 30-1/2

    158 / 148

  • 6 22-1836-07

    TUH1C100A9481A

    Upflow / Horizontal

    97,00092,15095.0

    35 - 6