Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-14 XR 80 TDD1A060A9241B, TDD1A060A9361B, TDD1B060A9361B, TDD1B080A9361B, TDD1B080A9451B TDD1B100A9451B, TDD1C100A9481B, TDD1C100A9541B TDD1C120A9541B, TDD1D120A9601B, TDD1D140A9601B Single-Stage Fan Assisted Combustion System

Trane-Commercial - Downflow/Horizontal Right or … · 2021. 1. 22. · Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace PUB. NO. 22-1671-14 XR 80 TDD1A060A9241B,

  • Upload
    others

  • View
    16

  • Download
    0

Embed Size (px)

Citation preview

  • Downflow/Horizontal Right or Downflow/Horizontal LeftInduced Draft Gas Furnace

    PUB. NO. 22-1671-14

    XR 80TDD1A060A9241B, TDD1A060A9361B, TDD1B060A9361B, TDD1B080A9361B, TDD1B080A9451B TDD1B100A9451B, TDD1C100A9481B, TDD1C100A9541BTDD1C120A9541B, TDD1D120A9601B, TDD1D140A9601B

    Single-Stage Fan Assisted Combustion System

  • © 2016 Trane All Rights Reserved 2 22-1671-14

    General Features

    Natural Gas ModelsCentral Heating furnace designs are certified by the American and Cana-dian Gas Associations for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.

    Safe OperationThe Integrated System Control has solid state devices, which continuously moni-tor for presence of flame, when the sys-tem is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety.

    Quick HeatingDurable, cycle tested, heavy gauge alu-minized steel heat exchanger quickly transfers heat to provide warm condi-tioned air to the structure.

    BurnersMulti-port In-shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas.

    Integrated System ControlExclusively designed operational pro-gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self-diagnostics for ease of service. Also contains connection points for E.A.C./humidifier.

    AIR LEAKAGEAir leakage less than 2% of design airflow rate in accordance with ASHRAE 193.

    Air DeliveryThe 4-speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.

    StylingHeavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel fin-ish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass.

    Features and General OperationThe XR 80 High Efficiency Gas Fur-nace employs an adaptive Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch.

  • 22-1671-14 3

    Contents

    General Features 2Features and Benefits 4

    Standard Equipment 4Optional Equipment 5

    General Data 6TDD1A060A9241B 6TDD1A060A9361B 6TDD1B060A9361B 6TDD1B080A9361B 7TDD1B080A9451B 7TDD1B100A9451B 7TDD1C100A9481B 8TDD1C100A9541B 8TDD1C120A9541B 8TDD1D120A9601B 9TDD1D140A9601B 9

    Performance Data 10Electrical Data 12Field Wiring 14Dimensions 16

  • 4 22-1671-14

    Features and Benefits

    • Power supply 115/1/60

    • Multi-port In-shot burners

    • Integrated solid state control with self- diagnostics

    • Silicon Nitride hot surface igniter with adaptive heat up

    • Complete front service access

    • Heavy gauge aluminized steel heat exchanger

    • Slide out blower assembly

    • Blower door safety switch

    • Direct drive, 4-speed motor

    • Optional L.P. conversion kit

    • Common vent

    • Left and right side knockout for venting

    • Selectable cooling fan off delay elimi-nates need for BAY24X045 time delay relay

    • Quiet slow opening gas valve

    • Downflow convertible to horizontal on left or right side

    • Insulated blower compartment

    • Accessory hook-up capability – Hum and EAC

    • Quiet induced draft blower

    • Left/right gas connection

    • 24 volt fuse

    • Manual reset flame rollout switches

    XR 80 Downflow/Horizontal Right or LeftStandard Equipment

  • 22-1671-14 5

    Features and Benefits

    Optional EquipmentThermostat ............................................................................................................................................................... BAYSTAT388 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ...............................................................................AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................ BAYSTAT305 [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ............................................................. TAYSTAT300C [ ]Propane Conversion Kit ......................................................................................................................................... BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) ......................................................TFM145A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ......................................................TFM175A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ............................................................TFM210A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ......................................................TFM245A9FR1 [ ] Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace)..............................................TFP175A9FR01 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ....................................................TFP210A9FR01 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace)..............................................TFP245A9FR01 [ ]Coil Enclosure (14-1/2" Wide Cabinets) .........................................................................................................BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ....................................................................................................... BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) .............................................................................................................. BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ....................................................................................................... BAYCLE24A2430A [ ]Filter Access Door Kit .............................................................................................................................................. BAYFLTR206 [ ]Downflow Subbase .................................................................................................................................................. BAYBASE205 [ ]High Altitude Pressure Switch Kit .............................................................................................................................BAYHALT248 [ ]

  • 6 22-1671-14

    General Data

    Product Specifications 1MODEL

    TYPE

    RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.

    BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

    COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

    FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

    VENT — Size (in.)

    HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

    ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

    GAS VALVE

    PILOT SAFETY DEVICEType

    BURNERS — TypeNumber

    POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

    PIPE CONN. SIZE (IN.)

    DIMENSIONSCrated (In.)

    WEIGHTShipping (Lbs.) / Net (Lbs)

    TDD1A060A9241B

    Downflow / Horizontal

    60,00048,00080.0

    35 - 65

    DIRECT10 x 7

    14

    See Fan Performance Table1/5

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3000115/1/60

    1.0

    NoHigh Velocity

    2 - 14x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    3 — 453 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot3

    115/1/605.515

    1/2

    H x W x D41 x 15-1/2 x 29-1/2

    129 / 119

    TDD1A060A9361B

    Downflow / Horizontal

    60,00048,00080.0

    30 - 60

    DIRECT11 x 7

    14

    See Fan Performance Table1/2

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3000115/1/60

    1.0

    NoHigh Velocity

    2 - 14x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    3 — 453 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot3

    115/1/6011.615

    1/2

    H x W x D41 x 15-1/2 x 29-1/2

    129 / 119

    1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea

    level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

    TDD1B060A9361B

    Downflow / Horizontal

    60,00048,00080.0

    30 - 60

    DIRECT10 x 7

    14

    See Fan Performance Table1/3

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3000115/1/60

    1.0

    NoHigh Velocity

    2 - 14x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    3 — 453 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot3

    115/1/6011.615

    1/2

    H x W x D41 x 18-1/2 x 29-1/2

    134 / 124

  • 22-1671-14 7

    Product Specifications 1MODEL

    TYPE

    RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.

    BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

    COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

    FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

    VENT — Size (in.)

    HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

    ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

    GAS VALVE

    PILOT SAFETY DEVICEType

    BURNERS — TypeNumber

    POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

    PIPE CONN. SIZE (IN.)

    DIMENSIONSCrated (In.)

    WEIGHTShipping (Lbs.) / Net (Lbs)

    General Data

    TDD1B080A9451B

    Downflow / Horizontal

    80,00064,00080.0

    35 - 65

    DIRECT10 x 8

    14

    See Fan Performance Table1/3

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3000115/1/60

    1.0

    NoHigh Velocity

    2 - 16x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    4 — 454 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot4

    115/1/609.815

    1/2

    H x W x D41 x 18-1/2 x 29-1/2

    146 / 135

    TDD1B080A9361B

    Downflow / Horizontal

    80,00064,00080.0

    35 - 65

    DIRECT10 x 7

    14

    See Fan Performance Table1/3

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3000115/1/60

    1.0

    NoHigh Velocity

    2 - 14x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    4 — 454 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot4

    115/1/609.015

    1/2

    H x W x D41 x 18-1/2 x 29-1/2

    146 / 135

    1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea

    level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

    TDD1B100A9451B

    Downflow / Horizontal

    100,00080,00080.0

    35 - 65

    DIRECT10 x 8

    14

    See Fan Performance Table1/3

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3200115/1/60

    1.0

    NoHigh Velocity

    2 - 16x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    5 — 455 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot5

    115/1/609.815

    1/2

    H x W x D41 x 18-1/2 x 29-1/2

    156 / 145

  • 8 22-1671-14

    General Data

    Product Specifications 1MODEL

    TYPE

    RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.

    BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

    COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

    FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

    VENT — Size (in.)

    HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

    ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

    GAS VALVE

    PILOT SAFETY DEVICEType

    BURNERS — TypeNumber

    POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

    PIPE CONN. SIZE (IN.)

    DIMENSIONSCrated (In.)

    WEIGHTShipping (Lbs.) / Net (Lbs)

    1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea

    level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

    TDD1C100A9481B

    Downflow / Horizontal

    100,00080,00080.0

    35 - 65

    DIRECT10 x 8

    14

    See Fan Performance Table1/2

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3000115/1/60

    1.0

    NoHigh Velocity

    2 - 16x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    5 — 455 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot5

    115/1/6011.615

    1/2

    H x W x D41 x 22 x 29-1/2

    166 / 154

    TDD1C100A9541B

    Downflow / Horizontal

    100,00081,00080.0

    30 - 60

    DIRECT11 x 10

    14

    See Fan Performance Table1/2

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3000115/1/60

    1.0

    NoHigh Velocity

    2 - 14x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    5 — 455 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot5

    115/1/6013.420

    1/2

    H x W x D41 x 22 x 29-1/2

    167 / 155

    TDD1C120A9541B

    Downflow / Horizontal

    120,00096,00080.0

    35 - 65

    DIRECT11 x 10

    14

    See Fan Performance Table1/2

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3000115/1/60

    1.0

    NoHigh Velocity

    2 - 16x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    6 — 456 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot6

    115/1/6013.420

    1/2

    H x W x D41 x 22 x 29-1/2

    170 / 158

  • 22-1671-14 9

    Product Specifications 1MODEL

    TYPE

    RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.

    BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

    COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

    FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

    VENT — Size (in.)

    HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

    ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

    GAS VALVE

    PILOT SAFETY DEVICEType

    BURNERS — TypeNumber

    POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

    PIPE CONN. SIZE (IN.)

    DIMENSIONSCrated (In.)

    WEIGHTShipping (Lbs.) / Net (Lbs)

    General Data

    TDD1D140A9601B

    Downflow / Horizontal

    140,000113,000

    80.045 - 75

    DIRECT11 x 10

    14

    See Fan Performance Table3/4

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3000115/1/60

    1.0

    NoHigh Velocity

    2 - 16x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    7 — 457 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot7

    115/1/6013.820

    1/2

    H x W x D41 x 25_-1/2 x 28

    196 / 183

    TDD1D120A9601B

    Downflow / Horizontal

    120,00096,00080.0

    35 - 65

    DIRECT11 x 10

    14

    See Fan Performance Table1/2

    1075115/1/60

    CentrifugalDirect - 1

    1/50 - 3000115/1/60

    1.0

    NoHigh Velocity

    2 - 16x20 - 1in.

    4 Round

    Aluminized Steel - Type I

    20

    6 — 456 — 56

    Redundant - Single Stage

    Hot Surface Ignition

    Multi-port In-shot6

    115/1/6013.420

    1/2

    H x W x D41 x 25-1/2 x 29-1/2

    189 / 176

    1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea

    level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

  • 10 22-1671-14

    Performance Data

    * May be "A" or "T"

    FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.)

    MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90

    *DD1A060A9241B4 -3 -2 -1 -

    HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

    12001025838722

    1155988808689

    1111951779656

    1056905742618

    1001859704579

    924797646528

    848735588478

    774646502376

    701558415275

    *DD1A060A9361B*DD1B060A9361B

    4 -3 -2 -1 -

    HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

    148013021115956

    142912761100947

    137512291070918

    131811881035888

    128211411000859

    11001088965824

    11121024918788

    1029953859741

    959882790682

    *DD1B080A9361B4 -3 -2 -1 -

    HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

    152313171123942

    149613071119943

    146312611106931

    142012421082920

    136912231056898

    131011751016868

    12431122976833

    11721060930795

    11001000880760

    *DD1B080A9451B4 -3 -2 -1 -

    HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

    1798138412101005

    175013671150970

    169213331108808

    164213001075775

    157512751042767

    150012331008733

    14251192967700

    13251142925675

    12251083867617

    *DD1B100A9451B4 -3 -2 -1 -

    HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

    176713821130840

    173113541138831

    166913231115815

    161512921085792

    154612541054762

    146912071015731

    13921177977700

    13001108938654

    11461038877625

    *DD1C100A9481B4 -3 -2 -1 -

    HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

    1965164514071202

    1915162713981208

    1865160513871205

    1805157513751195

    1740153513471166

    1670148213181140

    1587142112751105

    1500133011901045

    137012201095970

    *DD1B100A9541B4 -3 -2 -1 -

    HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

    2165196217051492

    2113192716881467

    2060189116711442

    1995183916361414

    1929178616001385

    1842172415471346

    1755166214921307

    1674158114351243

    1593150013771179

    *DD1C120A9541B4 -3 -2 -1 -

    HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

    2100191716721485

    2049188716561478

    1997185716391470

    1958184216311448

    1918182716231426

    1852175115601388

    1785167414961349

    1695159414271278

    1604151413581207

    *DD1D120A9601B4 -3 -2 -1 -

    HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

    2241198117211476

    2202196217051466

    2163194216881456

    2106190416711440

    2049186616531423

    1979180516111392

    1908174315691361

    1804168015151302

    1700161714611243

    *DD1D140A9601B4 -3 -2 -1 -

    HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red

    2377211518061527

    2321208117931507

    2265204617791486

    2199199217381473

    2133193816961459

    2050187216551422

    1967180516141384

    1877172715561329

    1786164914971273

  • 22-1671-14 11

    Performance Data

    CFM VS. TEMPERATURE RISE

    MODEL700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400

    *DD1A060A9241B 63 56 49 44 40

    *DD1A060A9361B 56 49 44 40 37 34 32

    *DD1B060A9361B 56 49 44 40 37 34 32

    *DD1B080A9361B 59 54 49 46 42

    *DD1B080A9451B 64 57 52 48 44 41

    *DD1B100A9451B 62 57 53 49 46 44 41

    *DD1C100A9481B 62 57 53 49 46 44 41 39 37

    *DD1C100A9541B 62 57 53 49 46 44 41 39 37 35 34 32 31

    *DD1C120A9541B 59 56 52 49 47 44 42 40

    *DD1D120A9601B 59 56 52 49 47 44 42 40

    *DD1D140A9601B 69 65 61 58 55 52 49 47 45

    * First letter may be "A" or "T" From C341712 Sh. 1 Rev. 03

  • 12 22-1671-14

    (continued on next page)

    WIRING DIAGRAM

    From Dwg. D342568P02

  • 22-1671-14 13

    SCHEMATIC DIAGRAM

    From Dwg. D342568P02

  • 14 22-1671-14

    Field Wiring

    FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY

    FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)

    From Dwg. 21B341437 Rev. 1

    From Dwg. 21B341436 Rev. 1

  • 22-1671-14 15

    Field Wiring

    From Dwg. 21B341423 Rev. 1

    From Dwg. 21B341422 Rev. 1

  • Trane 6200 Troup HighwayTyler, TX 75707www.trane.com

    Since The Trane Company has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.

    Literature Order Number 22-1671-14

    File Number 22-1671-14

    Supersedes 22-1671-13

    Date 05/16

    TD

    D1

    OU

    TL

    INE

    DR

    AW

    ING

    (AL

    L D

    IME

    NS

    ION

    S A

    RE

    IN IN

    CH

    ES

    )

    1-1/

    2” X

    2-1

    /2”

    OVA

    LG

    AS

    CO

    NN

    ECTI

    ON

    Ø 1

    -5/8

    ” H

    OLE

    WIT

    H P

    LUG

    Ø 1

    -5/8

    ” H

    OLE

    W

    ITH

    PLU

    G (3

    )

    Ø 7

    /8”

    HO

    LE W

    ITH

    PLU

    GEL

    ECTR

    ICA

    L C

    ON

    NEC

    TIO

    N

    (ALT

    ERN

    ATE)

    MO

    DE

    LD

    IM "

    A"

    DIM

    "B

    "D

    IM "

    C"

    DIM

    "D

    "

    *DD

    1A06

    0A92

    41B

    , *D

    D1A

    060A

    9361

    B14

    -1/2

    "9-

    5/8"

    13-1

    /4"

    13"

    *DD

    1B06

    0A93

    61B

    , *D

    D1B

    080A

    9361

    B*D

    D1B

    080A

    9451

    B, *

    DD

    1B10

    0A94

    51B

    17-1

    /2"

    9-5/

    8"16

    -1/4

    "16

    "

    *DD

    1C10

    0A94

    81B

    , *D

    D1C

    100A

    9541

    B*D

    D1C

    120A

    9541

    B21

    "13

    -1/1

    6"19

    -3/4

    "19

    -1/2

    "

    *DD

    1D12

    0A96

    01B

    , *D

    D1D

    140A

    9601

    B24

    -1/2

    "15

    -5/1

    6"23

    -1/4

    "23

    "