2
KroMassCal Sizing Customer: AZUL ECUADOR Ing. Evelyn Fernández Tag No.: FQ-01 Reference: Medidor masico coriolis Diesel Physical data Media : diesel fuel (-) Temperature : 35.0 C Pressure : 9.2 PSI gauge Density : 836.5 kg/m³ standard Viscosity : 4.28 cP Flow type : Volume flow Q-Max value : 190.0 USGPM (gal/min) Meter selection Meter : OPTIMASS 1000 - S 50 Flow range : 6.579436 ... 190.0 USGPM (gal/min) KroMassCal 1.4.0.1 KroMassCal-Coremodule 1.1.0.2 KMC-Database 1.2.0.5 Units-Database 1.0.0.3 Pressure drop [PSI] Flow rate [USGPM (gal/min)] Pressure drop graph for OPTIMASS 1000 - S 50 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 1.8 0 20 40 60 80 100 120 140 160 180 200 Flow (gal/min)] Delta p [PSI] 6.58 0.00569 11.40 0.01588 20.90 0.03844 30.40 0.06874 39.90 0.10676 49.40 0.15235 58.90 0.20541 68.40 0.26583 77.90 0.33351 87.40 0.40839 96.90 0.49040 106.40 0.57947 115.90 0.67557 125.40 0.77863 134.90 0.88863 144.40 1.00552 153.90 1.12927 163.40 1.25984 172.90 1.39722 182.40 1.54136 190.00 1.66153 Page 1 of 2

Hoja de Selección P 9-2psi Q 190GMP - TAG FQ-01

Embed Size (px)

DESCRIPTION

Instrumentacion

Citation preview

  • KroMassCal Sizing

    Customer: AZUL ECUADOR Ing. Evelyn Fernndez

    Tag No.: FQ-01Reference: Medidor masico coriolis Diesel

    Physical data

    Media : diesel fuel (-)Temperature : 35.0 CPressure : 9.2 PSI gaugeDensity : 836.5 kg/m standardViscosity : 4.28 cPFlow type : Volume flowQ-Max value : 190.0 USGPM (gal/min)

    Meter selection

    Meter : OPTIMASS 1000 - S 50Flow range : 6.579436 ... 190.0 USGPM (gal/min)

    KroMassCal 1.4.0.1 KroMassCal-Coremodule 1.1.0.2 KMC-Database 1.2.0.5 Units-Database 1.0.0.3

    Pre

    ssur

    e dr

    op [P

    SI]

    Flow rate [USGPM (gal/min)]

    Pressure drop graph for OPTIMASS 1000 - S 50

    0.0

    0.2

    0.4

    0.6

    0.8

    1.0

    1.2

    1.4

    1.6

    1.81.8

    0 20 40 60 80 100 120 140 160 180 200

    Flow[USGPM (gal/min)]

    Delta p[PSI]

    6.58 0.0056911.40 0.0158820.90 0.0384430.40 0.0687439.90 0.1067649.40 0.1523558.90 0.2054168.40 0.2658377.90 0.3335187.40 0.4083996.90 0.49040106.40 0.57947115.90 0.67557125.40 0.77863134.90 0.88863144.40 1.00552153.90 1.12927163.40 1.25984172.90 1.39722182.40 1.54136190.00 1.66153

    Page 1 of 2

  • KroMassCal SizingKroMassCal 1.4.0.1 KroMassCal-Coremodule 1.1.0.2 KMC-Database 1.2.0.5 Units-Database 1.0.0.3

    Err

    or o

    f mea

    sure

    men

    t [%

    ]

    Flow rate [USGPM (gal/min)]

    Error of measurement for OPTIMASS 1000 - S 50

    2.5

    2.0

    1.5

    1.0

    0.5

    0.0

    0.5

    1.0

    1.5

    2.0

    2.5

    0 90 180 270 360 450 540 630 720 810 900900

    < operating flow rate

    Flow[USGPM (gal/min)]

    Error %

    6.58 1.5150.99 0.3395.40 0.24139.81 0.21184.22 0.20228.64 0.19273.05 0.18317.46 0.18361.87 0.17406.28 0.17450.69 0.17495.10 0.17539.51 0.17583.92 0.17628.34 0.16672.75 0.16717.16 0.16761.57 0.16805.98 0.16850.39 0.16885.92 0.16

    Vel

    ocity

    at o

    utle

    t [m

    /s]

    Flow rate [USGPM (gal/min)]

    Velocity graph for OPTIMASS 1000 - S 50

    0.0

    0.6

    1.2

    1.8

    2.4

    3.0

    3.6

    4.2

    4.8

    5.4

    6.06.0

    0 20 40 60 80 100 120 140 160 180 200

    Flow[USGPM (gal/min)]

    Velocity[m/s]

    6.58 0.19611.40 0.34020.90 0.62430.40 0.90839.90 1.19149.40 1.47558.90 1.75868.40 2.04277.90 2.32587.40 2.60996.90 2.893106.40 3.176115.90 3.460125.40 3.743134.90 4.027144.40 4.311153.90 4.594163.40 4.878172.90 5.161182.40 5.445190.00 5.672

    Page 2 of 2