InForm Superstructures Elabo LaboratorySystems L 50 Advantages Racks for bringing in power supply systems and measurement and testing equipment Elabo offers a multitude of electronic cassettes and electronic inserts, from the central fuse protection and switch unit to the emergency-off switch, all the way to AC and DC stabilisers and to other devices such as function generators or multi- meters. This means that the 3HU racks can support the devices of the 3HU system and the 6HU racks can support the devices of both the 3HU and the 6HU systems. Versions in 19" are possible. Storage elements and shelves The use of InForm profiles creates ad- ditional storage surfaces. For instance, by keeping individual handheld devices for further measurement at hand. Shelf unit racks Elabo offers not only the materials but also well-thought-out solutions for worksta- tion design. For instance with shelf racks, which can also be fastened above a meas- urement and testing rack. This means that every employee has his or her devices in place, and can. if necessary also store them away from third-party access in a lockable roller shutter cabinet. InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices or other objects can be placed on top of or in them in the case of shelf or storage racks.

InForm Superstructures Advantages - Enelec

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 50

Advantages

Racks for bringing in power supply systems and measurement and testing equipment

Elabo offers a multitude of electronic cassettes and electronic inserts, from the central fuse protection and switch unit to the emergency-off switch, all the way to AC and DC stabilisers and to other devices such as function generators or multi- meters. This means that the 3HU racks can support the devices of the 3HU system and the 6HU racks can support the devices of both the 3HU and the 6HU systems. Versions in 19" are possible.

Storage elements and shelves The use of InForm profiles creates ad-ditional storage surfaces. For instance, by keeping individual handheld devices for further measurement at hand.

Shelf unit racks Elabo offers not only the materials but also well-thought-out solutions for worksta-tion design. For instance with shelf racks, which can also be fastened above a meas-urement and testing rack. This means that every employee has his or her devices in place, and can. if necessary also store them away from third-party access in a lockable roller shutter cabinet.

InForm racks are fitted between the vertical profiles and thus ensure a

generous amount of open working table surface. Devices are installed directly

in the 3HU and 6HU racks, additional devices or other objects can be placed on

top of or in them in the case of shelf or storage racks.

Page 2: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 51

Advantages

Supply

All built-in components are supplied through a network bus rail. Inserts are guided exactly through the also modifi-able guide rails and connected securely to the network bus. The connectors are designed for operation with mains volt-age 400 V / 16 A AC.

Desktop racks 6HU

Elabo table racks, systems 6HU / 19" can hold insert plates and inserts. The re-quired access to the rear Z profile rails is always guaranteed due to the removable aluminium rear wall.

Aluminium

The vertical struts divide the desktop rack in the changeable width grid. They are therefore screwed onto the profile frame so that they can be removed. The cage nuts used allow the inserts to be mounted securely.

Desktop racks 3HU

On the desktop racks 3HU, the aluminium profile running longitudinally along the bottom of the unit lends additional sup-port to the sturdy frame construction. The required access to the rear Z profile rails is always guaranteed due to the removable aluminium rear wall.

The Elabo 3 HU eurocassette mains supply is carried out via the high-power connector with leading ground contact mounted on the rear side.

Unit

All Elabo desktop racks are made of 19 mm thick multiple-layer plywood. Thanks to the melamine resin coating, they are abrasion-proof and anti-glare.

The exception is the 3HU aluminium channel. This is made of a stable extruded aluminium profile. Thanks to the surround-ing groove of the channel, accessories such as illumination or gauges can be mounted there.

Page 3: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 52

07

95

1/3

07

-0C

rails

he

im

0795

1/30

7-0

Crail

sheim

07

95

1/3

07

-0C

rails

he

im

0795

1/30

7-0

Crail

sheim

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

System 60 mounting rails

Mounting rail

For holding sockets and data outlets as well as compressed air supply lines, made of pow-der coated steel plateFor table width 2000 mmFor table width 1800 mmFor table width 1600 mmFor table width 1500 mmFor table width 1200 mm

75-3H75-3K75-3N75-3L75-3M

1920 x 51 x 66 1720 x 51 x 66 1520 x 51 x 66 1420 x 51 x 66 1120 x 51 x 66

Plastic socket strip with mains connection plug and directly bypassed power outlet socket System GST-18, sockets ro-tated 45° for angle plug.Colour: black3 Schuko sockets5 Schuko socketsOn/Off switch, 3 Schuko socketsOn/Off switch, 5 Schuko socketsOptionally switched power outlet socket available

C1-8AC1-8B

C1-8C

C1-8D

Socket strip

C1-8GC1-8H

Socket strip

Plastic socket strip including power input plug for mains con-nection and directly bypassed power outlet socket. The sockets are designed for plugs angled at 45°. Colour: black1 2-pole illuminated On/Off switch2 10A circuit breakers3 sockets5 socketsOptionally switched power outlet socket available

Page 4: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 53

3-pole cable with a 1.5 mm2 cross-section, for mains connection and connection of the System 60 socket strips.

Schuko plug GST-18 socket L = 200 cmSchuko plug GST-18 socket L = 300 cmSchuko plug GST-18 socket L = 400 cm

GST-18 plug GST-18 socket L = 50 cmGST-18 plug GST-18 socket L = 00 cmGST-18 plug GST-18 socket L = 250 cm

C1-8V ZL200C1-8V ZL300C1-8V ZL400

C1-8W ZL50C1-8W ZL100C1-8W ZL250

Technical data Order no.

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Order no.

Dimensions in mm

Mains cable

Width Depth Height

Plastic strip with different modules

Emergency-off button (2 x NC contacts)

2x compressed air NW52x compressed air NW7.2

3x NFN2x RJ45 and 3x NFN

C1-8P

C1-8RC1-8S

C1-8Q Z01C1-8Q Z02

System strip

Plastic strip RJ45

2x RJ45 Cat. 5 shielded

2 x 2x RJ45 Cat. 6

C1-8Q

C1-8Q Z602

System strip

System 60 mounting rails

Plastic socket strip including power input plug for mains connection and directly by-passed power outlet socket. The sockets are designed for plugs angled at 45°. Colour: black1 2-pole illuminated On/Off switch2 10A circuit breakers1 residual current circuit breaker 25 A / 30 mA3 sockets or 5 sockets

C1-8JC1-8K

Socket strip

Page 5: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 54

The light grey coated extruded aluminium profile makes the power supply duct suit-able for the installation of simple power supply systems. Thanks to the surround-ing grooves, a multitude of accessories can be securely fastened in place, e.g. workstation lights, TFT holders or gauges.

AttachmentThe channel is fastened between the vertical profiles, which means that it can be fitted at variable heights – can also be modified after a purchase. Furthermore,

it can also be combined with other objects, e.g. with a storage element. 3 cable outlets each on the side and underneath allow simple cable routing.

WiringAlready designed with a 3-phase central wiring, the supply channel can be equipped immediately.

EquipmentFor the equipping of the channels, the insert plates from the 3HU system

of the Elabo Electronics range can be utilised in the 5.08 mm separation grid pursuant to DIN 41494 (1HP = 5.08 mm).

Power supply duct

System 3 HU

Technical data

For holding 372HPFor holding 332HPFor holding 294HPFor holding 276HPFor holding 216HP

Cover strips, suitable for groove width 8.4 mm. Colour: black: Customer can cut to size for the appropriate duct width

Width Depth Height

1928 x 160 x 142 1728 x 160 x 142 1528 x 160 x 142 1428 x 160 x 142 1128 x 160 x 142

Order no.

75-4E75-4A75-4D75-4B75-4C

System 3HU power supply duct

Dimensions in mm

2000 x 9 x 7(Length)

81-6N

Page 6: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 55

35345

1

657

DevicesFor inserts and insert plates for 3HU desktop racks, see Elabo Electronics Order Catalogue, Chapter 3HU.

Standardised separation grid3HU desktop racks are prepared for hold-ing 3HU front panels and 3HU inserts from the Elabo Electronics range in a 5.08 mm separation grid acc. DIN 41494 (1HP = 5.08 mm).

Other brands which accord to this stand-ard can also easily be installed into the racks.

Material and set-upThe rack body is made of 19 mm-thick, 3-layer fine chipboard in light grey. The 19" separation grid mechanism is integrated into the unit; longitudinal aluminium profiles at the front and the rear enable installation of the inserts.

At the rear, a removable aluminium back wall and an aluminium cooling profile run-ning along the front facilitate practical heat transmission.

ErgonomicsThe ergonomic 10° incline of the operat-ing front panel makes it easier for users to work at the bench racks, and makes the display easy to read.

Bearing loadElabo racks are connected with a basic carrier or terminal for particularly high stability.

Cooling profile

Desktop rack

Insert, eurocassette

Rear wall

Terminal

Vertical profile

Profile cover

DimensionsFor racks with terminal technology

System 3HU / 19"

Page 7: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 56

Desktop rack 3HU Technical data Width Depth Height Order no.

74-2G 74-2A 74-2D 74-2B 74-2C

74-2X

2000 x 320 x 206 1800 x 320 x 206 1600 x 320 x 206 1500 x 320 x 206 1200 x 320 x 206

34 x 123 x 657

Equipment width 376 HPEquipment width 336 HPEquipment width 296 HPEquipment width 276 HPEquipment width 216 HP

Vertical profile (in pairs) with fastening fittings and profile covers

Bare terminal Technical data Width Depth Height Order no.

73-5G73-5A73-5D73-5B73-5C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98 1128 x 105 x 98

Made of extruded aluminium profile with 3 mm aluminium front panels;can be retrofitted with socket inserts and lamp

Socket terminal Technical data Width Depth Height Order no.

73-6G73-6A73-6D73-6B73-6C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98 1128 x 105 x 98

2 illuminated rocker switches9 Schuko sockets9 Schuko sockets7 Schuko sockets5 Schuko sockets5 Schuko sockets

Technical data Width Depth Height Order no.

73-7G73-7A73-7D73-7B

73-7C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98

1128 x 105 x 98

2 illuminated rocker switches30 W lamp, light colour 8409 Schuko sockets9 Schuko sockets7 Schuko sockets5 Schuko sockets18 W lamp, light colour 8405 Schuko sockets

Example order for table width 1500 mm

InForm desktop rack 74-2BInForm vertical profile 74-2XInForm socket terminal 73-6B

Dimensions in mm

3HU racks with terminal technology

Lamp terminal

System 3HU / 19"

Page 8: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 57

Desktop rack 3HU Technical data Width Depth Height Order no.

74-2L

74-2N

74-2M

1186 x 330 x 206

1328 x 330 x 206

1470 x 330 x 206

132 HP, for table depth 800 mm160 HP, for table depth 900 mm188 HP, for table depth 1000 mm

No vertical profiles required.

Table depths 850, 950 and 1050 also available. Article number of the respective smaller table + ZSE (table depth 850 = 74-2L ZSE).

Bare corner terminal Technical data Width Depth Height Order no.

73-5L73-5N73-5M

1095 x 105 x 98 1234 x 105 x 98 1378 x 105 x 98

For table depth 800 mmFor table depth 900 mmFor table depth 1000 mmMade of aluminium extruded profile with 3 mm aluminium front panels; can be retrofitted with socket inserts and lamp

Table depths 850, 950 and 1050 are available, see 74-2L.

Socket terminal Technical data Width Depth Height Order no.

73-6L73-6N

73-6M

1095 x 105 x 98 1234 x 105 x 98

1378 x 105 x 98

Equipment:1 illuminated rocker switch6 Schuko sockets

2 illuminated rocker switches7 Schuko sockets

Table depths 850, 950 and 1050 are available, see 74-2L.

Lamp terminal Technical data Width Depth Height Order no.

73-7L73-7N

73-7M

1095 x 105 x 98 1234 x 105 x 98

1378 x 105 x 98

Equipment:18 W lamp, light colour 840

1 illuminated rocker switchWithout Schuko sockets

2 illuminated rocker switches7 Schuko sockets

Table depths 850, 950 and 1050 are available, see 74-2L.

Order example for table depth 1000 mm

InForm desktop rack 74-2MInForm corner socket terminal 73-6M

Dimensions in mm

3HU racks with terminal technology

System 3HU / 19"

Page 9: InForm Superstructures Advantages - Enelec

Dimensions in mm

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Elabo LaboratorySystems L 58

InForm Superstructures

Basic rack

The stabilising fitting 75-5V can also be used to increase the load capacity.

We would be happy to advise you.

75-5E75-5A75-5D75-5B75-5C

For table width 2000 mmFor table width 1800 mmFor table width 1600 mmFor table width 1500 mmFor table width 1200 mm

Colour: light grey

1928 x 143 x 581728 x 143 x 581528 x 143 x 581428 x 143 x 581128 x 143 x 58

For table width 2000 mmFor table width 1800 mmFor table width 1600 mmFor table width 1500 mmFor table width 1200 mm

Lock for organisation panel

75-5F75-5G75-5H75-5J75-5K

75-5R

1927 x 155 x 551727 x 155 x 551527 x 155 x 551427 x 155 x 551127 x 155 x 55

Organisation panel

The cable rakes for kink-free wire place-ment from the measur-ing line drawer outward is part of this unique Elabo cable manage-ment system.

Organisation panel set

Basic rack and organisa-tion panel set

For table width 2000 mmFor table width 1800 mmFor table width 1600 mmFor table width 1500 mmFor table width 1200 mm

Lock for organisation panel

75-5Q ZB200075-5Q ZB180075-5Q ZB160075-5Q ZB150075-5Q ZB1200

75-5R

Set for basic rack

Lamp, socket strip, connection cable and mains connection cable set

81-2Y Z03

81-2Y Z04

1 work station lamp 75-8L inc. mounting set 75-5P2 socket strips with 3 Schuko sockets C1-8A1 connection cable Schuko for socket strip 2 m1 network connection cable 2 m or 2.5 m

Only partial equipment pos-sible for table widths of up to 1500 mm for table widths starting with 1600 mm

3HU racks with basic racks - suitable for the utilisation of the unique Elabo cable management system

System 3HU / 19"

Page 10: InForm Superstructures Advantages - Enelec

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Width Depth Height Order no.

Dimensions in mm

Elabo LaboratorySystems L 59

InForm Superstructures

Lamp

75-8L

75-5P

909

Illuminant: 2 x 36 WConnection: 230-240 V/ 50/60 Hz / IP20, parabolic gridInc.. 2 fluorescent lamps, electronic ballastIncline angle: 0-35 degreesIllumination intensity:Emin 417 lx, Em: 655 lx, Emax: 843 lx

Mounting set

3HU racks with basic racks – suitable for the utilisation of the unique Elabo cable management system

3x Schuko sockets. Plastic socket strip with power input plug and directly bypassed power outlet socket. System GST-18, sockets turned 45° for angled plugs, black. C1-8A

Socket strip

System 60

for fastening in the basic rack

Mains connection cable

Schuko plug + GST 18/3Cable length: L = 3000 mmCable length: L = 5000 mm

C1-8V ZL300C1-8V ZL500

Mains connection cable

C1-8W ZL150C1-8W ZL250

Socket + plug GST 18/3Cable length: L = 1500 mmCable length: L = 2500 mm

3-pole cable with a 1.5 mm2 cross-section, for mains con-nection and connection of the System 60 socket strips.

Other lengths available on request.

System 3HU / 19"

Page 11: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 60

3HU racks with basic racks – suitable for the utilisation of the unique Elabo cable management system

Riser duct, narrow

Riser duct suitable for vertical profiles 74-2X ZH707 and 74-4X ZH850

Riser duct for mounting onto the rear side of InForm alu-minium multi-groove profiles; double-sided, with brush pro-file segment at side for cable feed. Made of powder coated metal plate.Colour: light or basalt grey

Inc. mounting material

34 x 59 x 530 75-8Q ZH530

Riser duct, wide

Riser duct below basic rack

Riser duct for mounting onto the sides of InForm aluminium multi-groove profiles; double-sided, with brush profile segment at side for cable feed. Made of powder coated metal plate.Colour: light or basalt greyInc. mounting material

120 x 51.5 x 440 75-8P ZH440

Desktop rack 3HU

74-2G Z0174-2A Z0174-2D Z0174-2B Z0174-2C Z01

74-2X ZH707

2000 x 320 x 206 1800 x 320 x 206 1600 x 320 x 206 1500 x 320 x 206 1200 x 320 x 206

34 x 123 x 707

Equipment width 376 HPEquipment width 336 HPEquipment width 296 HPEquipment width 276 HPEquipment width 216 HP

Vertical profile (in pairs) with fastening fittings and profile covers

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

System 3HU / 19"

Page 12: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 61

35345

1

801

MaterialThe unit is made of 19 mm-thick, 3-layer melamine resin-coated chipboard. The edges are protected with plastic edge strips. The racks are equipped with a sys-tem profile frame. Colour: light grey.

DivisionsAll frame divisions are screwed to each other and can be dismantled so that retro- fitting is easily possible. The racks have guide rails and a 6-pole bus system with a leading ground contact. All racks are wired ready for connection.

ErgonomicsThe racks are ergonomically mounted above the tabletop using vertical profiles which have to be ordered separately. The cable is fed through the vertical profile.The ergonomic 10° incline of the operat-ing front panel makes it easier for users to work at the bench racks, and makes the display easy to read.

Bearing loadElabo racks are connected with a basic carrier or terminal for particularly high stability.

Cooling profile

Desktop rack

Insert, System 6HU

Rear wall Terminal

Vertical profile

Profile cover

System 6HU / 19"

DevicesInserts and insert plates for 6HU desktop racks, see Elabo Electronics Order Cata-logue, Chapter 6HU and 19".

DimensionsFor racks with terminal technology

Page 13: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 62

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

6HU racks with terminal technology

Desktop rack Technical data Width Depth Height Order no.

74-4G74-4A74-4D74-4B74-4C

74-4X

2000 x 369 x 350 1800 x 369 x 350 1600 x 369 x 350 1500 x 369 x 350 1200 x 369 x 350

34 x 123 x 801

For 16 WUFor 15 WUFor 13 WUFor 12 WUFor 9 WU

Desktop rack vertical profile (in pairs) with fastening fittings and profile covers

Bare terminal Technical data Width Depth Height Order no.

73-5G73-5A73-5D73-5B73-5C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98 1128 x 105 x 98

Made of aluminium extruded profile with 3 mm aluminium front panels; can be retrofitted with socket inserts and lamp

Socket terminal Technical data Width Depth Height Order no.

73-6G73-6A73-6D73-6B73-6C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98 1128 x 105 x 98

2 illuminated rocker switches9 Schuko sockets9 Schuko sockets7 Schuko sockets5 Schuko sockets5 Schuko sockets

Lamp terminal Technical data Width Depth Height Order no.

73-7G73-7A73-7D73-7B

73-7C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98

1128 x 105 x 98

2 illuminated rocker switches30 W lamp, light colour 8409 Schuko sockets9 Schuko sockets7 Schuko sockets5 Schuko sockets18 W lamp, light colour 8405 Schuko sockets

Example order for table width 1500 mm

InForm desktop rack 74-4BInForm vertical profile 74-4XInForm socket terminal 73-6B

Dimensions in mm

System 6HU / 19"

Page 14: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 63

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

AUS

NOT

6HU racks with terminal technology

Desktop corner racks Technical data Width Depth Height Order no.

74-4L

74-4N

74-4M

1186 x 369 x 350

1328 x 369 x 350

1470 x 369 x 350

5 WU, for table depth 800 mm5 WU, for table depth 900 mm7 WU, for table depth 1000 mm

No vertical profiles required.

Table depths 850, 950 and 1050 also available. Article number of the respective smaller table + ZSE (table depth 850 = 74-4L ZSE).

Bare corner terminal Technical data Width Depth Height Order no.

73-5L73-5N73-5M

1095 x 105 x 98 1234 x 105 x 98 1378 x 105 x 98

For table depth 800 mmFor table depth 900 mmFor table depth 1000 mmMade of aluminium extruded profile with 3 mm aluminium front panels; can be retrofitted with socket inserts and lamp

Table depths 850, 950 and 1050 are available, see 74-4L.

Socket terminal Technical data Width Depth Height Order no.

73-6L73-6N

73-6M

1095 x 105 x 98 1234 x 105 x 98

1378 x 105 x 98

Equipment:1 illuminated rocker switch6 Schuko sockets

2 illuminated rocker switches7 Schuko sockets

Table depths 850, 950 and 1050 are available, see 74-4L.

Lamp terminal Technical data Width Depth Height Order no.

73-7L73-7N

73-7M

1095 x 105 x 98 1234 x 105 x 98

1378 x 105 x 98

Equipment:18 W lamp, light colour 840

1 illuminated rocker switchWithout Schuko sockets

2 illuminated rocker switches7 Schuko sockets

Table depths 850, 950 and 1050 are available, see 74-4L.

Order example for table depth 1000 mm

InForm desktop corner racks 74-4MInForm corner socket terminal 73-6M

Dimensions in mm

System 6HU / 19"

Page 15: InForm Superstructures Advantages - Enelec

Dimensions in mm

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Elabo LaboratorySystems L 64

InForm Superstructures

6HU racks with basic racks – suitable for the utilisation of the unique Elabo cable management system

Basic rack

The stabilising fitting 75-5V can also be used to increase the load capacity.

We would be happy to advise you.

75-5E75-5A75-5D75-5B75-5C

For table width 2000 mmFor table width 1800 mmFor table width 1600 mmFor table width 1500 mmFor table width 1200 mm

Colour: light grey

1928 x 143 x 581728 x 143 x 581528 x 143 x 581428 x 143 x 581128 x 143 x 58

For table width 2000 mmFor table width 1800 mmFor table width 1600 mmFor table width 1500 mmFor table width 1200 mm

Lock for organisation panel

75-5F75-5G75-5H75-5J75-5K

75-5R

1927 x 155 x 551727 x 155 x 551527 x 155 x 551427 x 155 x 551127 x 155 x 55

Organisation panel

The cable rakes for kink-free wire place-ment from the measur-ing line drawer outward is part of this unique Elabo cable manage-ment system.

Organisation panel set

Basic rack and organisa-tion panel set

For table width 2000 mmFor table width 1800 mmFor table width 1600 mmFor table width 1500 mmFor table width 1200 mm

Lock for organisation panel

75-5Q ZB200075-5Q ZB180075-5Q ZB160075-5Q ZB150075-5Q ZB1200

75-5R

Set for basic rack

Lamp, socket strip, connection cable and mains connection cable set

81-2Y Z03

81-2Y Z04

1 work station lamp 75-8L inc. mounting set 75-5P2 socket strips with 3 Schuko sockets C1-8A1 connection cable Schuko for socket strip 2 m1 network connection cable 2 m or 2.5 m

Only partial equipment pos-sible for table widths of up to 1500 mmFor table widths of up to 1600 mm

System 6HU / 19"

Page 16: InForm Superstructures Advantages - Enelec

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Width Depth Height Order no.

Dimensions in mm

Elabo LaboratorySystems L 65

InForm Superstructures

6HU racks with basic racks – suitable for the utilisation of the unique Elabo cable management system

Lamp

75-8L

75-5P

909

Illuminant: 2 x 36 WConnection: 230-240V/ 50/60 Hz/IP20, parabolic gridInc.. 2 fluorescent lamps, electronic ballastIncline angle: 0-35 degreesIllumination intensity:Emin 417 lx, Em: 655 lx, Emax: 843 lx

Mounting set

Riser duct, narrow

Riser duct to match the vertical profiles 74-2X ZH707 and74-4X ZH850

Riser duct for mounting onto the rear side of InForm alu-minium multi-groove profiles; double-sided, with brush pro-file segment at side for cable feed. Made of powder coated metal plate.Colour: light or basalt grey

Inc. mounting material

34 x 59 x 530 75-8Q ZH530

Riser duct, wide

Riser duct underbasic rack

Riser duct for mounting onto the sides of InForm aluminium multi-groove profiles; double-sided, with brush profile segment at side for cable feed. Made of powder coated metal plate.Colour: light or basalt greyInc. mounting material

120 x 51.5 x 440 75-8P ZH440

Desktop rack

74-4G74-4A74-4D74-4B74-4C

74-4X ZH850

2000 x 369 x 350 1800 x 369 x 350 1600 x 369 x 350 1500 x 369 x 350 1200 x 369 x 350

34 x 123 x 850

For 16 WUFor 15 WUFor 13 WUFor 12 WUFor 9 WU

Desktop rack vertical profile (in pairs) with fastening fittings and profile covers

AUS

NOT

AUS

NOT

System 6HU / 19"

Page 17: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 66

35345

1

821

ShelvesThe cut edges have plastic edge strips. Depending on the width of the shelf racks, one or two height-adjust-able shelves are supplied.

InstallationWith vertical profiles, to be ordered separately, and a terminal or the basic rack, the shelf unit racks can be installed over the tabletop.

If a cable feed is required, it can be carried out via cable clamps in the vertical profiles.

MaterialShelf racks can be used to store devices and files. They are complete with one rear wall made of 19 mm-thick, melamine resin-coated 3-layer fine chipboard panels.

Roller shutters / sliding doorsVersions with either roller shutters or sliding doors with lock are available. With this version, the front of the shelf is not inclined.

Shelf unit rack

Terminal

Profile cover

Vertical profile

Shelf unit racks

DimensionsFor racks with terminal technology

Page 18: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 67

Shelf unit rack Technical data Width Depth Height Order no.

74-6G74-6A

74-6D74-6B74-6C

74-6X

2000 x 320 x 370 1800 x 320 x 370

1600 x 320 x 370 1500 x 320 x 370 1200 x 320 x 370

34 x 123 x 821

2 intermediate walls and two height-adjustable shelves

1 intermediate wall and one height-adjustable shelf

Shelf unit rack vertical profile (in pairs) with fastening fittings and profile covers 78-2P

Bare terminal Technical data Width Depth Height Order no.

73-5G73-5A73-5D73-5B73-5C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98 1128 x 105 x 98

Made of aluminium extruded profile with 3 mm aluminium front panels; can be retrofitted with socket inserts and lamp

Socket terminal Technical data Width Depth Height Order no.

73-6G73-6A73-6D73-6B73-6C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98 1128 x 105 x 98

2 illuminated rocker switches9 Schuko sockets9 Schuko sockets7 Schuko sockets5 Schuko sockets5 Schuko sockets

Lamp terminal Technical data Width Depth Height Order no.

73-7G73-7A73-7D73-7B

73-7C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98

1128 x 105 x 98

2 illuminated rocker switches30 W lamp, light colour 8409 Schuko sockets9 Schuko sockets7 Schuko sockets5 Schuko sockets18 W lamp, light colour 8405 Schuko sockets

Dimensions in mm

Shelf unit rack

With roller shuttersWith sliding doors

Technical data Width Depth Height Order no.

74-6M74-6H74-6J74-6K74-6L

74-6S74-6N74-6P74-6Q74-6R

74-6X ZH843

2000 x 410 x 370 1800 x 410 x 370 1600 x 410 x 370 1500 x 410 x 370 1200 x 410 x 370

2000 x 370 x 370 1800 x 370 x 370 1600 x 370 x 370 1500 x 370 x 370 1200 x 370 x 370 34 x 123 x 843

Also with roller shutters

Also with sliding doors

Matching vertical profile (in pairs)

Shelf unit racks

Shelf racks also available with the unique Elabo Cable Management system (see 3HU and 6HU racks).

Page 19: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 68

35345

1

480

Material and benefitsStorage elements consisting of a 30 mm-thick and melamine resin-coated 3-layer fine chipboard with postformed edge at front. With this extra storage level, the tabletop remains completely free of measurement devices and files etc.

ExtendableThe storage elements can be retrofitted as a third level onto InForm system tables at any time. To do this, you need additional height profiles and a terminal or a basic rack.

The use of the base rack and the organi-sation panel, the cables can be placed efficiently, even when third-party devices are utilised.

Storage element

Terminal

Profile cover

Vertical profile

EquipmentTerminals are available with different equipment: sockets, lamp. earth leakage circuit breaker, emergency-off switch. Basic racks can also be outfitted with dif-ferent combinations of equipment.

Capacity (area load):Up to 1600 mm width: 80 kgUp to 2000 mm width: 60 kg

F1

Storage elements

Page 20: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 69

Storage element

With carrier plate rounded off at the front

Technical data Width Depth Height Order no.74-7G74-7A74-7D74-7B74-7C

74-8G74-8A74-8D74-8B74-8C

74-7X

2000 x 400 x 30 1800 x 400 x 30 1600 x 400 x 30 1500 x 400 x 30 1200 x 400 x 30

2000 x 400 x 30 1800 x 400 x 30 1600 x 400 x 30 1500 x 400 x 30 1200 x 400 x 30

34 x 123 x 480

Standard

ESD

Vertical profile (in pairs)

Bare terminal Technical data Width Depth Height Order no.

73-5G73-5A73-5D73-5B73-5C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98 1128 x 105 x 98

Made of aluminium extruded profile with 3 mm aluminium front panels; can be retrofitted with socket inserts and lamp

Socket terminal Technical data Width Depth Height Order no.

73-6G73-6A73-6D73-6B73-6C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98 1128 x 105 x 98

2 illuminated rocker switches9 Schuko sockets9 Schuko sockets7 Schuko sockets5 Schuko sockets5 Schuko sockets

Lamp terminal

With sockets

Technical data Width Depth Height Order no.

73-7G73-7A73-7D73-7B

73-7C

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98

1128 x 105 x 98

2 illuminated rocker switches30 W lamp, light colour 8409 Schuko sockets9 Schuko sockets7 Schuko sockets5 Schuko sockets18 W lamp, light colour 8405 Schuko sockets

Dimensions in mm

Lamp terminal

With sockets, earth leakage circuit breaker, emergency off

Technical data Width Depth Height Order no.

73-7V73-7Q73-7T73-7R

73-7S

1928 x 105 x 98 1728 x 105 x 98 1528 x 105 x 98 1428 x 105 x 98

1128 x 105 x 98

2 illuminated rocker switchesFI 2-pole 30 mA,Unwired emergency-off switch30 W lamp, light colour 8406 Schuko sockets6 Schuko sockets4 Schuko sockets2 Schuko sockets18 W lamp, light colour 8402 Schuko sockets

Storage elements

Storage elements also available with the unique Elabo Cable Management system (see 3HU and 6HU racks).

Page 21: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 70

Corner storage elementDepth 400 mmStrength 30 mm

Technical data Width for Table depth Order no.

1186 800 74-7L1328 900 74-7N1470 1000 74-7M

1186 800 74-8L1328 900 74-8N1470 1000 74-8M

Standard

ESD

No vertical profiles required.

Bare corner terminalDepth 105 mmHeight 98 mm

Technical data

Made of extruded aluminium profile with 3 mm aluminium front panels;can be retrofitted with socket inserts and lamp

Socket terminalDepth 105 mmHeight 98 mm

Technical data

Equipment:1 illuminated rocker switch6 Schuko sockets

2 illuminated rocker switches7 Schuko sockets

Lamp terminalDepth 105 mmHeight 98 mm

Technical data

Equipment:18 W lamp, light colour 8401 illuminated rocker switchWithout Schuko sockets2 illuminated rocker switches7 Schuko sockets

Order example for table depth 800 mm

InForm corner storage element 74-7LInForm corner lamp terminal 73-7L

Dimensions in mm

Width for Table depth Order no.

1095 800 73-5L1234 900 73-5N1378 1000 73-5M

Width for Table depth Order no.

1095 800 73-6L

1234 900 73-6N

1378 1000 73-6M

Width for Table depth Order no.

1095 800 73-7L

1234 900 73-7N1378 1000 73-7M

Width for Table depth Order no.

1166 850 73-5L ZSE1307 950 73-5N ZSE1449 1050 73-5M ZSE

Width for Table depth Order no.

1166 850 73-6L ZSE

1307 950 73-6N ZSE

1449 1050 73-6M ZSE

Width for Table depth Order no.

1166 850 73-7L ZSE

1307 950 73-7N ZSE1449 1050 73-7M ZSE

Width for Table depth Order no.

1257 850 74-7L ZSE1399 950 74-7N ZSE1540 1050 74-7M ZSE

1257 850 74-8L ZSE1399 950 74-8N ZSE1540 1050 74-8M ZSE

Corner storage elements

Page 22: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 71

30°

The functional shelf can be mounted on all desktop racks and attachment elements between the vertical profiles – within easy reach above the work surface, as a third level for storage of measurement devices. The table surface remains clear. The shelf is continuously height-adjustable and can be inclined forwards or backwards by 30°. In addition, it is self-supporting, i.e. it is used without basic rack or terminal.

Anti-slip protectionThe functional shelves have extruded aluminium profiles powder coated in light grey with grooves at the front and rear. A recessed fibre rail prevents the devices slipping when inclined. Functional shelf

with system profile

AccessoriesStorage trays, tool holders and an adjust-able inclined shelf can be attached to the face end of the system profile.

Capacity (area load):Up to 1600 mm width: 80 kgUp to 2000 mm width: 60 kg

Functional shelf

Page 23: InForm Superstructures Advantages - Enelec

InForm Superstructures

Elabo LaboratorySystems L 72

Corner functional shelf Technical data Width Depth Height Order no.

75-6L75-6Q75-6M

75-7L75-7Q75-7M

1186 x 400 x 34 1328 x 400 x 34 1470 x 400 x 34

1186 x 400 x 34 1328 x 400 x 34 1470 x 400 x 34

For table depth 800 mmFor table depth 900 mmFor table depth 1000 mm

ESDFor table depth 800 mmFor table depth 900 mmFor table depth 1000 mm

Table depths 850, 950 and 1050 also available. Article number of the respective, some what smaller table + ZSE (table depth 850 ESD = 75-7L ZSE).

Inclined shelf Technical data

For attaching to a functional shelf

Inclined shelf panel made of aluminium sheet with anti-slip coating, horizontally-adjustable across the entire width of the functional shelf and lockable using knurled screw.

Width Depth Height

210 x 300

Order no.

75-6N

Functional shelf Technical data

StandardFor table width 2000For table width 1800For table width 1600For table width 1500For table width 1200

ESDFor table width 2000For table width 1800For table width 1600For table width 1500For table width 1200

Width Depth Height

1928 x 400 x 34 1728 x 400 x 34 1528 x 400 x 34 1428 x 400 x 34 1128 x 400 x 34

1928 x 400 x 34 1728 x 400 x 34 1528 x 400 x 34 1428 x 400 x 34 1128 x 400 x 34

Order no.

75-6G75-6A75-6D75-6B75-6C

75-7G75-7A75-7D75-7B75-7C

Dimensions in mm

Functional shelf

Page 24: InForm Superstructures Advantages - Enelec

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Order no.Width Depth Height

Technical data Width Depth Height Order no.

Dimensions in mm

Elabo LaboratorySystems L 73

InForm Superstructures

M5

M5M6M8

M5

M5M6M8

M5

M5M6M8

Vertical profile

78-2C78-2D78-2E

34 x 123 x 250 34 x 123 x 480 34 x 123 x 801

InForm vertical profiles for any and all racks, consisting of 2 aluminium profiles with fasten-ing fittings and profile covers

Vertical profile 250 (in pairs)Vertical profile 480 (in pairs)Vertical profile 801 (in pairs)

Snap-on nuts

78-2G

78-2H

78-2J

78-2HZM5

Spring nut M5 for small groove

Snap-on nut M6for large groove

Snap-on nut M8for large groove

Snap-on nut M5 for large groove

Riser duct

For racks with terminal technology

78-2M78-2N

52 x 57 x 413 52 x 57 x 413

InForm riser duct for side in-stallation onto a vertical profile, for cable feed to the terminal and rack

Riser duct leftRiser duct right

Profile cover

InForm profile cover, flat de-sign (in pairs) made of plastic for vertical profiles

34 x 123 x 8 78-2R

Accessories for superstructures