75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211 Page 1 of 2
24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.beasensors.com
LZR - I30 /S600 PARAMETERS
A - NO
P - NC
A - NOP - NC P - NC
A - NOP - NCA - NO
R1
R2
A = activeP = passive
NO = normally openNC = normally closed
OUTPUT CONF IGURAT ION
MINIMUM OBJECT S IZE
The distances between the curtains depends on the mounting height and side.When mounted on the left, the distance between curtain C1 and curtain C4 is approximately 4 in. for every 3 ft (mounting height).EXAMPLE: At 15 ft. mounting height, the distance between C1 and C4 is 20 in.
LZR T IPS
T H E L Z R - I 3 0 R E Q U I R E S 1 0 - 3 5 V C L E A N D C P O W E R
( N O N - R E C T I F I E D )
A F T E R 3 0 M I N U T E S , T H E S E N S O R L O C K S A C C E S S T O
T H E R E M O T E C O N T R O L S E S S I O N . P O W E R C Y C L E T H E
S E N S O R T O R E C O N F I G U R E .
A BEA UNIVERSAL REMOTE IS REQUIRED TO
CONF IGURE THE LZR - I30 .
UN IVERSAL REMOTE CONTROL T IPS
T O Q U E S T I O N A PA R A M E T E R , P R E S S
A F T E R U N L O C K I N G A N D C H O O S I N G A
PA R A M E T E R . C O U N T T H E L E D F L A S H E S .
C O N S I D E R U S I N G A N A C C E S S C O D E
TO SET AN ACCESS CODE:
TO DELETE AN ACCESS CODE:
V I RT U A L P U S H P L AT E :
FA C T O RY D E FA U LT S :
A LWAY S F I N I S H A N A D J U S T M E N T S E S S I O N
B Y L A U N C H I N G A S E T U P :
T O T U R N T H E L E D s O N / O F F :
F O R V I S I B L E L A S E R B E A M S :
T O C H A N G E O R Q U E S T I O N A PA R A M E T E R ,
S TA RT B Y P R E S S I N G T H E A N D F I N I S H
T H E S E S S I O N B Y P R E S S I N G
# OF ACT IVE DETECT ION CURTAINS
Increase in case of snow, dead leaves, etc.
UNCOVERED ZONE
2 i n 4 i n 6 i n 8 i n 10 i n
MOUNTING S IDE
left right left center
WITH BACKGROUND WITHOUT BACKGROUND
right
indoor outdoorlow
outdoormed
outdoorhigh
Choose between environment or object.
IMMUNITY F I LTER
FOR CRITICAL ENVIRONMENTS(RAIN, SNOW, FOG)
indoor outdoorlow
outdoormed
outdoorhigh
FOR CRITICAL OBJECTS(BLACK CARS)
O F F 3 i n 4 i n 6 i n 8 i n
OUTPUT ACT IVAT ION DELAY
O F F 100ms 200ms 300ms 400ms 500ms 600ms 700ms 800ms 900ms
The relays are triggered when the detection duration ≥ the selected time.
CURTAIN C1 C2 C3 C4
CURTAIN IS INACTIVE ON BOTH FIELDS
CURTAIN IS ACTIVE ON OPTIONAL FIELD
CURTAIN IS ACTIVE ON SAFETY FIELD
CURTAIN IS ACTIVE ON BOTH FIELDS
C1 + C2 ARE ACTIVE ON SAFETY FIELDC3 + C4 ARE ACTIVE ON OPTIONAL FIELD
C1 IS ACTIVE ON BOTH FIELDSC2 + C3 ARE ACTIVE ON SAFETY FIELDC4 IS INACTIVE
ALL CURTAINS ARE ACTIVE ON BOTH FIELDS
EXAMPLE CONF IGURAT IONS
OPT IONAL F IELD WIDTH
OPT IONAL F IELD HE IGHT
SAFETY F IELD WIDTH
SAFETY F IELD HE IGHT
UNIVERSAL REMOTE CONTROL | LZR - I30 /S600
Page 2 of 2 75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211
24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.beasensors.com
MICROWAVE PARAMETERS
INFRARED PARAMETERS
LEARN T IME EXPLANAT ION
UNIVERSAL REMOTE CONTROL T IPS
T O Q U E S T I O N A PA R A M E T E R , P R E S S
A F T E R U N L O C K I N G A N D C H O O S I N G A
PA R A M E T E R . C O U N T T H E L E D F L A S H E S .
C O N S I D E R U S I N G A N A C C E S S C O D E
TO SET AN ACCESS CODE:
TO DELETE AN ACCESS CODE:
R E L AY C O N F I G U R AT I O N :
FA C T O RY D E FA U LT S :
A LWAY S F I N I S H A N A D J U S T M E N T S E S S I O N
B Y L A U N C H I N G A S E T U P :
T O C H A N G E O R Q U E S T I O N A PA R A M E T E R ,
S TA RT B Y P R E S S I N G T H E A N D F I N I S H
T H E S E S S I O N B Y P R E S S I N G
1-4
low
SENS IT IV ITY
XXS XS S > > > > XL XXL
0.5s 1s 2s 3s 4s 5s 6s 8s 9s7s
ACT IVAT ION RELAY HOLD T IME
bi uni unidepart
bi = two-way detectionuni = one-way detection towards sensoruni depart = one-way detection away from sensor
DETECT ION MODE
1 2 3 4 5 6
REJECT ION MODE
1: DETECTION OF ALL KINDS OF TARGETS IN MOTION2: DETECTION OF ALL KINDS OF TARGETS IN MOTION + INTERFERENCE IMMUNITY3: LOW ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY4: MEDIUM ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY5: HIGH ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY6: HIGHEST ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY
NOTES FACTORY DEFAULTS
DOOR DOOR DOOR DOORDOOR1 2 3 4 5
DOOR DOOR DOOR DOOR6 7 8 9
IR PATTERN S IZE
FREQUENCY
IR IMMUNITY
AUTOMATIC LEARN T IME
low
high
medium high
30s 1 min 2 min 5 min 10 min 20 min 1 h 1.5 h 2 h
I R TARGET S IZE
DOOR
3x3
DOOR
4x4
DOOR
3x2
DOOR
1x2 1x1
2x2
IF AN OBJECT IS IN THE PRESENCE DETECTION FIELD AND REMAINS MOTIONLESS FOR LONGER THAN THE PROGRAMMED LEARN TIME, THE SENSOR WILL ACCEPT THE OBJECT AS PART OF ITS BACKGROUND/REFERENCE POINT AND WILL DROP THE DETECTION SIGNAL.
**INFINITY ( ∞ ) WILL NEVER LEARN A NEW BACKGROUND**∞
L
UNIVERSAL REMOTE CONTROL | FALCON & IS40 SER IES