Upload
others
View
9
Download
0
Embed Size (px)
Citation preview
Upflow/HorizontalTwo-stage CondensingGas-Fired Furnace
XV 90TUY060,080,100,120R9VVariable Speed BlowerVariable Speed Inducer
PUB. NO. 22-1682-05-0802 (EN)
TDD-D-1
2 Pub. No. 22-1682-05-0802 (EN)
GeneralFeatures
© 2002 American Standard Inc. All Rights Reserved
NATURAL GAS MODELSCentral heating furnace designs arecertified by the International ApprovalServices (IAS) for both natural andL.P. gas. Limit setting and rating datawere established and approved understandard rating conditions usingAmerican National Standards Institutestandards.
SAFE OPERATIONThe Integrated System Control has solidstate devices, which continuouslymonitor for presence of flame, when thesystem is in the heating mode ofoperation. Dual solenoid combinationgas valve and regulator provide extrasafety.
QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to increaseefficiency and provide a positivedischarge of gas fumes to the outside.
BURNERSMulti-port In-shot burners will give yearsof quiet and efficient service. All modelscan be converted to L.P. gas withoutchanging burners.
INTEGRATED SYSTEM CONTROLExclusively designed operationalprogram provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self diagnostics forease of service. Also containsconnection points for E.A.C./humidifier.
CONDENSATE DRAINBuilt-in trap which can drain from eitherside when the furnace is installed upflow.
AIR DELIVERYThe variable speed, direct drive blowermotor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speeds ondemand from room thermostat. Theblower door safety switch will prevent orterminate furnace operation when theblower door is removed.
SECONDARY HEAT EXCHANGERThe XV 90 has a special type 29-4C™stainless steel secondary heatexchanger to reclaim heat from fluegases which would normally be lostoutside.
STYLINGHeavy gauge steel and “wrap-around”cabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heat exchangersection of the cabinet is completely linedwith foil faced fiberglass insulation. Thisresults in quiet and efficient operationdue to the excellent acoustical andinsulating qualities of fiberglass. Built-inbottom pan and alternate bottom, left orright side return air connection in verticalposition.
FEATURES ANDGENERAL OPERATIONThe XV 90 High Efficiency Gas Furnacesemploy a Hot Surface Ignition system,which eliminates the waste of a constantburning pilot. The integrated systemcontrol lights the main burners upon ademand for heat from the roomthermostat. Complete front serviceaccess.
a. Low energy power venter.b. Vent proving differential switch.
3Pub. No. 22-1682-05-0802 (EN)
Contents
Feature Summary
Features and BenefitsStandard EquipmentOptional Equipment
General DataTUY060R9V3VTUY080R9V3VTUY100R9V4VTUY120R9V5V
Performance Data
Electrical Data
Field Wiring
Dimensions
2
4
6
7
11
12
15
4 Pub. No. 22-1682-05-0802 (EN)
XV 90 STANDARD EQUIPMENT
Featuresand Benefits
• Variable speed indoor blower
• Silicon Nitride Igniter with adaptive
heat up
• Variable speed induced draft blower
• Direct/Non-Direct vent option
• Fused 24 volt control circuit
• Manual reset burner safety switches
• Power supply 115/1/60
• Convertible to horizontal on left side
• 2-stage gas valve
• PVC venting-1 or 2 pipe option
• Accessory hook-up capability
• Integrated solid state control with
self-diagnostics
• Attractive color accents
• Heavy gauge aluminized steel heat
exchanger
• Multi-port In-shot burners
• HInged blower door
• Perfect fit door latches
• Insulated blower door
• Gasketed blower door
• Internal filter rack
• Standard filter sizes
• Two tone color
• Complete front service access
• Left/right gas connection
• Adjustable fan off times
• Cleanable high velocity filters
• Optional L.P conversion kit
• Selectable cooling fan off delay
eliminates need for BAY24X045
time delay kit
• Lifetime limited primary heat
exchanger or secondary heat
exchanger warranty to original
owner (Residential use)
• 5 Year limited parts warranty
5Pub. No. 22-1682-05-0802 (EN)
Featuresand Benefits
OPTIONAL EQUIPMENT
Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... TAYSTAT241 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................... AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) .................................................................................... BAYSTAT305 [ ]Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling .................................................................. TAYSTAT302C [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling .................................................................. TAYSTAT300C [ ]Propane Conversion Kit ......................................................................................................................................... BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (14-1/2" Wide Gas Furnace) ......................................................... TFE145A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ......................................................... TFE175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ............................................................... TFE210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ......................................................... TFE245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .......................................................... TFM145A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................................... TFM175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ................................................................ TFM210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................................... TFM245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ..................................................... TFP145A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ..................................................... TFP175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) .......................................................... TFP210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ..................................................... TFP245A9FR0 [ ]Coil Enclosure (14-1/2" Wide Cabinets) .................................................................................................................. BAYCLE1400C [ ]Coil Enclosure (17-1/2" Wide Cabinets) .................................................................................................................. BAYCLE1700C [ ]Coil Enclosure (21" Wide Cabinets) ........................................................................................................................ BAYCLE2100C [ ]Coil Enclosure (24-1/2" Wide Cabinets) .................................................................................................................. BAYCLE2400C [ ]Side Filter Rack ........................................................................................................................................................ BAYFLTR200 [ ]Filter Kit/Horizontal Conversion TUY060, 080-R ......................................................................................................... BAYFLTR203 [ ]Filter Kit/Horizontal Conversion TUY100-R ................................................................................................................ BAYFLTR204 [ ]Filter Kit/Horizontal Conversion TUY120-R ................................................................................................................ BAYFLTR205 [ ]Filter Accessory Kit Upflow 14.5" Furnaces ............................................................................................................... BAYFLTR317 [ ]Filter Accessory Kit Upflow 21" Furnaces .................................................................................................................. BAYFLTR321 [ ]Filter Accessory Kit Upflow 24.5" Furnaces ............................................................................................................... BAYFLTR324 [ ]High Altitude Switch TUY060R .............................................................................................................................. BAYHALT2451 [ ]High Altitude Switch TUY080, 100R ...................................................................................................................... BAYHALT2461 [ ]High Altitude Switch TUY120R .............................................................................................................................. BAYHALT2471 [ ]Concentric Vent Kit ............................................................................................................................................... BAYVENT100A [ ]Sidewall Vent Termination Kit ................................................................................................................................. BAYVENT200B [ ]Manufactured/Mobile Home Kit ............................................................................................................................. BAYMFGH100A [ ]1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.
6 Pub. No. 22-1682-05-0802 (EN)
TUY-R9V PRODUCT SPECIFICATIONS1
MODEL
RATINGS21st Stage Input BTUH
1st Stage Capacity BTUH (ICS)32nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)3AFUE (ICS)Temp. Rise (Min.-Max.) °F.
BLOWER DRIVEDia.-Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts/Ph/Hz
COMBUSTION FAN - TYPEDrive - No. SpeedsMotor HP - RPMVolts/Ph/HzFL Amps
FILTER — Furnished?Type RecommendedFilter (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
DIRECT IGNITION DEVICEType
BURNERS — TypeNumber
POWER CONN. — V/Ph/Hz4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
DIMENSIONSCrated (In.)Uncrated
WEIGHTShipping (Lbs.)/Net (Lbs.)
TUY080R9V3V
5200049000800007300092.5
35 - 65
DIRECT10 x 8
1VARIABLE
SEE FAN PERF. TABLE1/2
VARIABLE115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/15 - 5000115/1/60
1.1
YESHIGH VELOCITY1 X 17 X 25 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
4 - 454 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT4
115/1/608.415
0.50
SEE OUTLINE DRAWING
H X W X D41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
158/148
TUY060R9V3V
3900037000600005600093.0
35 - 65
DIRECT10 x 8
1VARIABLE
SEE FAN PERF. TABLE1/2
VARIABLE115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/15 - 5000115/1/60
1.1
YESHIGH VELOCITY1 X 17 X 25 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
3 - 453 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT3
115/1/608.415
0.50
SEE OUTLINE DRAWING
H X W X D41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
158/146
TUY100R9V4V
65000620001000009300093.0
35 - 65
DIRECT10 x 10
1VARIABLE
SEE FAN PERF. TABLE1
VARIABLE115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/15 - 5000115/1/60
1.1
YESHIGH VELOCITY1 - 20 X 25 X 1
3 ROUND
ALUMINIZED STEEL TYPE 1
20
5 - 455 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT5
115/1/6011.415
0.50
SEE OUTLINE DRAWING
H X W X D41-3/4 X 23 X 30-1/2
SEE OUTLINE DRAWING
171/160
TUY120R9V5V
7800074000120000112000
92.540 - 70
DIRECT10 x 10
1VARIABLE
SEE FAN PERF. TABLE1
VARIABLE115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/25 - 5000115/1/60
1.1
YESHIGH VELOCITY1 - 24 X 25 X 1
3 ROUND
ALUMINIZED STEEL TYPE 1
20
6 - 456 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT6
115/1/6011.415
0.50
SEE OUTLINE DRAWING
H X W X D41-3/4 X 26-1/2 X 30-1/2
SEE OUTLINE DRAWING
205/193
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above
input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
GeneralData
7Pub. No. 22-1682-05-0802 (EN)
PerformanceData
*UY060R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
1.5
LOW(350 CFM/TON)
ON ON OFF ONCFM
WATTS57565
57590
575125
550155
-
NORMAL(400 CFM/TON)
ON ON OFF OFFCFM
WATTS64070
640110
640140
630175
-
HIGH(450 CFM/TON)
ON ON ON OFFCFM
WATTS70085
700125
700160
700200
-
2.0
LOW(350 CFM/TON)
OFF ON OFF ONCFM
WATTS700100
700130
700170
700210
-
NORMAL(400 CFM/TON)
OFF ON OFF OFFCFM
WATTS800115
800155
800200
800250
-
HIGH(450 CFM/TON)
OFF ON ON OFFCFM
WATTS900140
900195
900240
900290
-
2.5
LOW(350 CFM/TON)
ON OFF OFF ONCFM
WATTS875130
875180
875230
875270
-
NORMAL(400 CFM/TON)
ON OFF OFF OFFCFM
WATTS1000175
1000235
1000285
1000335
900310
HIGH(450 CFM/TON)
ON OFF ON OFFCFM
WATTS1125235
1125295
1125345
1100370
925318
3
LOW(350 CFM/TON)
OFF OFF OFF ONCFM
WATTS1050195
1050260
1050305
1050350
920315
NORMAL(400 CFM/TON)
OFF OFF OFF OFFCFM
WATTS1200275
1200330
1200385
1100385
940330
HIGH(450 CFM/TON)
OFF OFF ON OFFCFM
WATTS1325360
1325425
1300460
1175425
1000365
NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
*UY060R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity =2nd Stage Capacity =
37,00056,000
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
6005785
60057110
60057155
60057190
-
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
7004990
70049130
70049175
70049210
-
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
77544105
77544155
77544195
77544240
-
HIGH OFF OFFCFM
TEMP. RISEWATTS
87039135
87039185
87039235
87039290
-
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
86061
140
92057
200
92057245
92057300
67079
245
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
100053190
100053255
100053305
100053340
70075
255
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
112547250
112547315
112547370
102551
355
77568
285
HIGH OFF OFFCFM
TEMP. RISEWATTS
125042340
125042405
125042445
110048390
100053355
NOTES: * First letter may be "A" or "T" ** Factory setting
8 Pub. No. 22-1682-05-0802 (EN)
PerformanceData
TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
(See Notes)
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
2.0
LOW(350 CFM/TON)
ON ON OFF ONCFM
WATTS75084
750122
750154
720185
710221
NORMAL(400 CFM/TON)
ON ON OFF OFFCFM
WATTS840109
840146
840181
840226
820264
HIGH(450 CFM/TON)
ON ON ON OFFCFM
WATTS940136
940177
940215
940274
940318
2.5
LOW(350 CFM/TON)
OFF ON OFF ONCFM
WATTS850113
850150
870200
890250
890295
NORMAL(400 CFM/TON)
OFF ON OFF OFFCFM
WATTS960150
990200
1000230
1020305
1010350
HIGH(450 CFM/TON)
OFF ON ON OFFCFM
WATTS1080195
1110255
1120315
1120365
1080390
3.0
LOW(350 CFM/TON)
ON OFF OFF ONCFM
WATTS1020175
1020225
1040280
1050330
1050375
NORMAL(400 CFM/TON)
ON OFF OFF OFFCFM
WATTS1170240
1180300
1200365
1200415
1130420
HIGH(450 CFM/TON)
ON OFF ON OFFCFM
WATTS1290310
1320410
1350470
1340520
1150440
3.5
LOW(350 CFM/TON)
OFF OFF OFF ONCFM
WATTS1170250
1190315
1210370
1210435
1100405
NORMAL(400 CFM/TON)
OFF OFF OFF OFFCFM
WATTS1360365
1390445
1400500
1360535
1210475
HIGH(450 CFM/TON)
OFF OFF ON OFFCFM
WATTS1360355
1390450
1400520
1350535
1180460
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position. 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
TUY080R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity =2nd Stage Capacity =
49,00073,000
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
80056105
80056140
80056180
80056220
80056265
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
86052115
88051
165
89050215
92048265
91049320
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
96046150
99045200
100044230
102044310
101044350
HIGH OFF OFFCFM
TEMP. RISEWATTS
108041
195
111040255
112040315
112040365
108041
390
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
110062205
110062260
112061
320
112061
370
109063400
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
121057265
124055340
126054410
126054470
113061
430
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
136050365
139049445
140049500
136050535
121057475
HIGH OFF OFFCFM
TEMP. RISEWATTS
136050355
139049450
140049520
135051
535
118058465
NOTES: ** Factory setting
9Pub. No. 22-1682-05-0802 (EN)
PerformanceData
TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
(See Notes)
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
3.0
LOW(350 CFM/TON)
ON ON OFF ONCFM
WATTS1040165
1040220
1040270
1030320
1030375
NORMAL(400 CFM/TON)
ON ON OFF OFFCFM
WATTS1210235
1210285
1230360
1230415
1230475
HIGH(450 CFM/TON)
ON ON ON OFFCFM
WATTS1340390
1370390
1400465
1390525
1370580
3.5
LOW(350 CFM/TON)
OFF ON OFF ONCFM
WATTS1200225
1220280
1230365
1250425
1230485
NORMAL(400 CFM/TON)
OFF ON OFF OFFCFM
WATTS1390335
1430425
1430495
1430560
1400590
HIGH(450 CFM/TON)
OFF ON ON OFFCFM
WATTS1590490
1590575
1590625
1580685
1420615
4.0
LOW(350 CFM/TON)
ON OFF OFF ONCFM
WATTS1370325
1420415
1430490
1340550
1410595
NORMAL(400 CFM/TON)
ON OFF OFF OFFCFM
WATTS1640515
1640585
1640655
1590680
1420615
HIGH(450 CFM/TON)
ON OFF ON OFFCFM
WATTS1840700
1840780
1770795
1630725
1470655
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position. 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
TUY100R9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity =2nd Stage Capacity =
62,00093,000
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
92060130
92060180
92060220
92060280
92060320
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
102054165
102054220
102054260
101055310
100056365
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
116048220
116048260
116048325
116048390
115048430
HIGH OFF OFFCFM
TEMP. RISEWATTS
135041
320
138040400
140040470
140040540
139040585
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
129067275
129067355
133065430
134064490
132065545
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
141061
3561
146059455
146059520
146059590
137063590
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
164053530
164053590
164053660
160054695
141061
620
HIGH OFF OFFCFM
TEMP. RISEWATTS
197044855
192045895
178048820
166052760
152057695
NOTES: ** Factory setting
10 Pub. No. 22-1682-05-0802 (EN)
PerformanceData
TUY120R9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
(See Notes)
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
3.5
LOW(350 CFM/TON)
OFF ON OFF ONCFM
WATTS1210220
1210270
1220325
1230400
1230445
NORMAL(400 CFM/TON)
OFF ON OFF OFFCFM
WATTS1400305
1440390
1450465
1450510
1410560
HIGH(450 CFM/TON)
OFF ON ON OFFCFM
WATTS1590425
1600520
1610600
1600645
1380575
4.0
LOW(350 CFM/TON)
ON OFF OFF ONCFM
WATTS1390305
1400375
1430445
1440515
1420565
NORMAL(400 CFM/TON)
ON OFF OFF OFFCFM
WATTS1620420
1650530
1670595
1640660
1480600
HIGH(450 CFM/TON)
ON OFF ON OFFCFM
WATTS1840600
1830690
1820765
1670700
1490620
5
LOW(350 CFM/TON)
OFF OFF OFF ONCFM
WATTS1800570
1780630
1780705
1700695
1530615
NORMAL(400 CFM/TON)
OFF OFF OFF OFFCFM
WATTS2050845
2010875
1860805
1710735
1530655
HIGH(450 CFM/TON)
OFF OFF ON OFFCFM
WATTS2160995
2040935
1920875
1780805
1620730
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position. 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
TUY120R9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity =2nd Stage Capacity =
74,000112,000
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
109062165
112060225
108063270
107063310
101067380
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
121056220
120056280
120056330
118057395
116058455
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
134050295
136050350
137049425
138049495
133051
535
HIGH OFF OFFCFM
TEMP. RISEWATTS
143047390
157043490
158043565
157043625
139049565
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
166063485
169062590
168062640
164064675
146072600
MEDIUM LOW OFF ONCFM
TEMP. RISEWATTS
187056675
187056745
181058770
168062715
149070625
NORMAL ** ON OFFCFM
TEMP. RISEWATTS
206051
880
199053890
185057810
171061
750
153068665
HIGH OFF OFFCFM
TEMP. RISEWATTS
220048
1030
209050965
194054895
179058830
164064750
NOTES: ** Factory setting
11Pub. No. 22-1682-05-0802 (EN)
SCHEMATIC DIAGRAMS FOR GAS FURNACES
TUY060,080,100,120R9V-VLEGEND
ElectricalData
From Dwg. 21D341111 P03
12 Pub. No. 22-1682-05-0802 (EN)
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
FieldWiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING
From Dwg. 21B341127 Rev. 0
From Dwg. 21B341126 Rev. 0
FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
13Pub. No. 22-1682-05-0802 (EN)
FieldWiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg. 21B341125 Rev. 1
From Dwg. 21B341124 Rev. 1
FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
14 Pub. No. 22-1682-05-0802 (EN)
FieldWiring
FIELD WIRING DIAGRAM FOR 2 STAGE HEATING TWO STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg. 21B341128 Rev. 0
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
15Pub. No. 22-1682-05-0802 (EN)
Dimensions
TUY
-R9V
-V O
UTL
INE
DR
AW
ING
(AL
L D
IME
NS
ION
S A
RE
IN
IN
CH
ES
)
Since Trane has a policy of continuous product improvement, it reserves the right to change design andspecifications without notice.
TraneA business of American Standard Companieswww.trane.com
File No. PL-UN-FURN-TDD-D-1 3/98 P.I.
Supersedes TDD-D-1 8/95