113
TRACE Environmental 124 Chalmers Street, Surry Hills, NSW 2010 The Property Investors Alliance 7 July 2015 Preliminary Site Investigation 42-66 Junction Road Schofields, NSW

Preliminary Site Investigation

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Preliminary Site Investigation

TRACE Environmental

124 Chalmers Street, Surry Hills, NSW 2010

The Property Investors Alliance

7 July 2015

Preliminary Site Investigation

42-66 Junction Road

Schofields, NSW

Page 2: Preliminary Site Investigation

TRACE Environmental

124 Chalmers Street, Surry Hills, NSW 2010

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

Prepared for:

The Property Investors Alliance

Revision Date Author Reviewer/Approver Date Issued

REV0 20/05/15 MT AK Internal draft

REV1 21/05/15 MT AK 25/05/15

REV2 07/07/15 MT AK 07/07/15

Author:

Matthew Tendam

Principal Environmental Engineer

7 B.Eng (Env)

Approved: Andrew Kita

Principal Engineer

B.Eng (Geol, Hons)

Ref No.: 2.13

Disclaimer: THIS DOCUMENT IS SUBJECT TO LIMITATIONS NOTED

Page 3: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance i

Table of Contents

Executive Summary ............................................................................................................................................ 3

1 Introduction .................................................................................................................................................... 1

2 Scope of Works ............................................................................................................................................. 1

3 Site Description and Setting .......................................................................................................................... 3

3.1 Site Identification ................................................................................................................................. 3

3.2 Site Description & Adjoining Land Uses.............................................................................................. 3

3.3 Surrounding Land Use ........................................................................................................................ 4

3.4 Surface Water Bodies ......................................................................................................................... 4

3.5 Geology & Hydrogeology .................................................................................................................... 4

3.6 Registered Groundwater Bore Search ................................................................................................ 5

4 Site History and Background ......................................................................................................................... 6

4.1 Certificates of Title ............................................................................................................................... 6

4.2 Historical Aerial Photograph Review ................................................................................................... 7

4.3 Contaminated Land Record Review ................................................................................................... 8

4.4 Relevant Planning Information ............................................................................................................ 8

4.5 Acid Sulphate Soil ............................................................................................................................... 8

4.6 Saline Soils .......................................................................................................................................... 9

4.7 Dangerous Goods Search ................................................................................................................... 9

4.8 Historical Environmental Investigations .............................................................................................. 9

5 Initial Conceptual Site Model ....................................................................................................................... 10

5.1 Preliminary CSM Summary and Risk Assessment ........................................................................... 11

5.2 Data Gaps and Uncertainties ............................................................................................................ 11

6 Conclusions and Recommendations ........................................................................................................... 12

6.1 Conclusions ....................................................................................................................................... 12

6.2 Recommendations ............................................................................................................................ 12

7 References .................................................................................................................................................. 13

8 Limitations .................................................................................................................................................... 14

Page 4: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance ii

Figures

Title Figure

Locality Plan ...................................................................................................................................................... 1

Site Plan ............................................................................................................................................................ 2

Appendices

Title Appendix

Site Survey ....................................................................................................................................................... A

Site Photographs .............................................................................................................................................. B

Dial Before You Dig Plans ................................................................................................................................ C

Current and Historical Titles ............................................................................................................................. D

Historical Aerial Photographs ........................................................................................................................... E

EPA Records Search Results ........................................................................................................................... F

Planning Certificates ......................................................................................................................................... G

Dangerous Goods Search Results ................................................................................................................... H

Page 5: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance iii

Executive Summary

Krikis Tayler Architects engaged TRACE Environmental on behalf of The Property Investors Alliance (PIA) to

undertake a Preliminary Site Investigation (PSI) for the property located at 42-66 Junction Road, Schofields,

NSW (the site). The PSI is required to determine if the historical land use/s have the potential to have

contaminated the subsurface at the site which could affect the proposed medium density residential

redevelopment. The PSI was completed in accordance with Schedule B2 of the National Environment

Protection (Assessment of Site Contamination) Measure, Amendment 2013 (NEPM).

Based on the findings of this PSI, the following is concluded:

The site has been used for low density residential land use purposes since at least 1955. Also, small

scale agricultural activities and horse rearing/riding has occurred on the site historically. The site was

developed in its current configuration between approximately 1970 and 1994;

The site land use is currently low density residential;

It is proposed to redevelop the site with approximately ten low-rise apartment buildings;

The results of the historic searches and site inspection undertaken did not indicate a high potential for

contaminating activities to have occurred at the site historically;

The site is located in a low sensitivity environmental setting based on the preliminary Conceptual Site

Model (CSM) developed, and nearby land uses;

The site is not located in an area of known acid sulphate soils; and

The BCC DCP 2014 - Schedule Two for the Riverstone Precinct indicates that the north-eastern and

south-western corners of the site may be located within a region of higher salinity soils. An overlay of

the information from the Department of Infrastructure Planning and Natural Resources: Salinity

Potential in Western Sydney (Map: 2002) onto current aerial photographs indicates the site is within

an area of moderate potential for saline soils. The BCC map does not indicate that the site is located

with an area of known aggressive saline soils.

Based on the results of the PSI, there is considered to be a low potential for contamination to have occurred

at the site as a result of the current and historic agricultural and residential land uses of the property, and the

site is considered suitable for the proposed medium density residential redevelopment. In view of this, a

Detailed Site Investigation (DSI) is not considered necessary prior to the proposed residential redevelopment

of the site.

In the event that soil is excavated and requires off-site disposal during redevelopment, the soil should be

tested and classified in accordance with NSW EPA guidelines prior to disposal. Any imported material

brought onto the site, to achieve construction levels or for landscaping purposes, must be validated as being

suitable for the proposed residential land use.

If site specific soil salinity information is required, a subsurface investigation should be completed with the

collection of soil samples for indications of salinity. This is typically undertaken as part of a Geotechnical

Investigation. If the data indicates highly saline and/or aggressive soils, the data should be reviewed by

appropriately qualified structural and geotechnical engineers to ensure the structural design of the proposed

development takes into account any potentially aggressive soils which may exist at the site. The design of

any building structural components should be completed in accordance with Australian Standard AS 2159-

2009 Piling: Design and Installation. This standard includes tables on exposure classification of soils and

groundwater based on their aggressiveness to concrete and steel.

Page 6: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 1 of 14

1 Introduction

Krikis Tayler Architects engaged TRACE Environmental on behalf of The Property Investors Alliance (PIA) to

undertake a Preliminary Site Investigation (PSI) for the property located at 42-66 Junction Road, Schofields,

NSW (the site). The PSI is required to determine if the historical land use/s have the potential to have

contaminated the subsurface at the site which could affect the proposed medium density residential

redevelopment. The PSI was completed in accordance with Schedule B2 of the National Environment

Protection (Assessment of Site Contamination) Measure, Amendment 2013 (NEPM).

A Locality Plan is presented in Figure 1 showing the location of the site, and a Site Plan showing the site

and surrounding features is presented in Figure 2.

The specific objectives of the PSI were to:

Assess the site condition relative to present and historical land uses;

Identify any current or historical potentially contaminating activities;

If applicable, identify the potential types and nature of contamination;

If applicable, identify potential human and ecological receptors;

Develop a preliminary Conceptual Site Model (CSM) to identify potential risks to human health and/or

ecological receptors that could potentially affect the use of the site; and

Provide conclusions and recommendations regarding the suitability of the site for the proposed

redevelopment, and identify any further investigation for potential site contamination, if considered

warranted.

2 Scope of Works

The following scope of works were undertaken in order to meet the objectives described above:

Conduct database searches and review of historical information from the following sources;

­ Current and historical certificates of title;

­ Council records including current and previous planning certificates;

­ NSW EPA administered environment management and contaminated land registers;

­ State Government records including a Dangerous Goods License search;

­ Review of available historical aerial photographs; and

­ Registered groundwater bore database search for bores in the site vicinity, to determine the

local hydrogeology and groundwater utilisation.

Determine the local environmental sensitivity, including geological, hydrogeological and hydrological

information and identification of nearby sensitive receptors;

Conduct an inspection of the site to:

­ Identify potential sources of contamination, assess surrounding sensitive land uses, and

evaluate the general condition of the site in relation to potential contamination;

Page 7: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 2 of 14

­ Identify known or suspected areas of potential concern (if any); and

­ Interview site personnel, if available, regarding previous site activities and features.

Develop an initial CSM of the site, outlining potential contamination sources, and exposure pathways

and receptors which may be impacted, and undertake a preliminary environmental risk assessment;

and

If required, assess the suitability of the site for the proposed land use, and outline any

recommendations for further investigation that may be warranted to assess for potential contamination

at the site based on the results of the PSI.

Page 8: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 3 of 14

3 Site Description and Setting

3.1 Site Identification

Details on the site are included in Table 3-1, below.

Table 3-1: Summary of Site Identification Details

ID Element Description

Site Address 42-66 Junction Road, Schofields, NSW

Lot/DP Lots 22 on DP 850117 Lot 25 and 26 on DP13137

Site Owner(s) Christopher and Lynne Lawlor James Cremona

Local Council Blacktown City Council

Site Coordinates 33o41’50.34”S 150

o52’38.75”E

Approximate Site Elevation Approximately 41mAHD

Site Area Approximately 41,000m2

A survey of the site and preliminary development plans are included in Appendix A.

3.2 Site Description & Adjoining Land Uses

A site inspection was completed by TRACE Environmental personnel on 30 March 2015. Photographs taken

during the site visit are included in Appendix B. Details of the site, as observed during the inspection and

gathered from other sources detailed in this report, are outlined in Table 3-2 below.

Table 3-2 Site Description

Category Observation

Current Use and Users/Occupiers

The site is approximately 41,000m2

in area. The site land use is currently low density residential with three separate dwellings; one on each lot listed above.

Future Use and Users/Occupiers

It is proposed to re-develop the site for medium density residential land use, comprising approximately ten low-rise apartment buildings. The future users of the site include construction workers during redevelopment and the future residents occupying the residences.

Current Zoning and Permitted Uses

All three lots that comprise the site are currently zoned as R3: Medium Density Residential (Blacktown Local Environment Plan 1988 and NSW Government’s Blacktown City Council Growth Centre Precincts Development Control Plan 2010) according to the Section 149 Certificate. Residential land use is a permitted use on the site.

Site features The site is roughly square in shape and covers an area of approximately 41,000m2. There

are three separate low density residential dwellings at the site (Photographs 1 through 3). The residence at 42 Junction Road appears to be unoccupied currently. Access to each residence is provided by driveways off Junction Road. There are two bitumen driveways and one unsealed driveway to provide access to 66 Junction Road. A pool is located on the 42 Junction Road property but appears that it has not been used recently (Photograph 4). There are also two unused small, metal sheds located at 42 Junction Road (Photograph 5) A series of metal and wood fences are installed to separate the various lots that comprise the site (Photographs 6 and 7). The former stable is still present in the central portion of the site. It is constructed of sheet metal and the walls have been covered with graffiti (Photograph 8). Most of the site is open, vegetated land with some trees (Photograph 9).

Page 9: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 4 of 14

Category Observation

Underground Services The site is serviced by above and below ground utilities, and service pits were noted during the site visit in the southeast corner of the site. TRACE Environmental conducted a Dial Before You Dig (DBYD) search on 20 May 2015 which shows the approximate locations of underground and above ground services on the site. The DBYD plans are included in Appendix C. The site is serviced by a reticulated water supply and municipal sewer system. Additionally, Telstra fibre optic, water mains and power lines run along Junction Road and Advance Street.

Chemicals, raw materials and intermediate products storage and use

Reportedly, no chemicals, raw materials or intermediate products are currently or historically stored or used on-site. No signs of underground storage tanks (USTs) were noted during the site visit. Dangerous Goods records for the site, obtained from WorkCover NSW, did not indicate any quantities of dangerous goods being stored at the site currently or in the past.

Waste generation and storage

No hazardous waste is currently generated or stored on-site. Typical domestic waste is temporarily stored in bins prior to off-site disposal.

Reported spills, chemical losses, discharges to land/water and/or incidents/accidents

A search of the NSW EPA Contaminated Land Record on 20 May 2015 returned no results for the site. There are no reports of spills or incidents at the site.

Contaminated Land Records

A search of the NSW EPA Contaminated Land Record on 20 May 2015 returned no results for the site.

Surface covering/ Vegetation

Most of the property is covered with landscaping/vegetation including turf, flower beds, grass and some trees.

Electrical transformers/power generation

No electrical transformers were noted on-site. The site is provided power via above ground services.

Topography and infilling The site and surrounds are relatively flat with a gentle slope toward the east across the site. Any importation of fill historically would likely be limited.

Surface drainage Surface water is expected to drain from the roof and via gutters and pipes to a municipal storm water conveyance system. Most of the stormwater would infiltrate into the ground or flow along the surface with the natural topography.

3.3 Surrounding Land Use

The site is located within a predominantly low density residential area. At the time of the inspection, the

surrounding land uses comprised:

North: Low density residential with additional low density residential beyond;

East: Junction Road with low density residential and uncleared and partially wooded land beyond;

South: Low density residential with Schofields Road beyond; and

West: Uncleared, partially wooded land with low density residential beyond.

3.4 Surface Water Bodies

The closest surface water body is Eastern Creek, which is located between 1 and 1.2km west, northwest and

southwest of the site. Eastern Creek appears to flow toward the north, and eventually discharges to the

Hawkesbury River located approximately 11.5km north of the site.

3.5 Geology & Hydrogeology

The Penrith 1:100,000 Geological Series Sheet 9035 (Ed 1) (Geological Survey of NSW, 1991) indicates that

the site is underlain shale, carbonaceous claystone, claystone, laminite, fine to medium grained lithic

sandstone and rare coal and tuff. Bedrock below the site is mapped as Wianamatta Group Bringelly shale of

Page 10: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 5 of 14

the middle Triassic period in the Mesozoic Era. Consistent with the lithology of surrounding sites, a layer of

unconsolidated, weather bedrock (overburden) exists above the bedrock. The site specific lithologic/geologic

conditions are not known at this time.

Groundwater may be present within the pore spaces of the overburden material and/or in the underlying

bedrock. The site specific hydrogeological conditions are not known at this time. However, regional

groundwater likely flows to the east and south east toward Strangers Creek with localised gradients in

various directions.

3.6 Registered Groundwater Bore Search

A search of the NSW NRAtlas database conducted on 27 March 2015, identified 14 registered bores within

an approximate 1 km radius of the site. However, no further information was available about these bores on

the NRAtlas website. The closest bore to the site is located approximately 290m to the southeast. Given the

distance and direction to this bore and likely direction of regional groundwater flow, it is not considered a

potential receptor of groundwater leaving the site. The other bores are located at greater distances to the

south, northwest, southwest and northeast. Given the distance and direction to this bores, they are unlikely

potential receptors of groundwater leaving the site.

Page 11: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 6 of 14

4 Site History and Background

Historical information was obtained for the site from a number of sources as presented in Table 4-1, below.

The results of the site historical and background information are further discussed in the following sections.

Table 4-1 Historical and Background Information Search

Source Location Comments

Current Title Feigl & Newell Current Title Documents are discussed below and copies are included in Appendix D.

Historical Title Feigl & Newell Historical Title Documents are discussed below and copies are included in Appendix D.

Aerial Photographs NSW Land & Property Information Aerial Photographs are discussed below and the images are included in Appendix E.

Contaminated Land Register NSW EPA No records were found and the search results are included in Appendix F.

Planning and Zoning Information Blacktown City Council Section 149 Certificates

The s149 certificate is discussed below and a copy is included in Appendix G.

Acid Sulfate Soils Search NSW Department of Land and Water Conservation Acid Sulfate Soil Risk Maps

The site is not located within Class 1 to 5 acid sulfate soils which is further discussed below.

Saline Soils Department of Infrastructure Planning and Natural Resources: Salinity Potential in Western Sydney Map: 2002

Blacktown City Council Development Control Plan 2014 (BCC DCP 2014)- Schedule Two for Riverstone Precinct

Small portions of the may be in areas for a higher risk of saline soils. This is further discussed below and maps are included in Appendix G.

WorkCover NSW – Dangerous Goods Search

WorkCover NSW Dangerous Goods search is discussed below and a copy of the search results is included in Appendix H.

4.1 Certificates of Title

Current and historical titles were obtained for the allotments comprising the site. As stated previously, the

site is currently described as Lots 25 and 26 on DP 13137 and Lot 22 on DP850117. Details are provided in

Tables 4-2 and 4-3, below.

Table 4-2: Summary of Current Titles

Lot and Deposited Plan Schedules and Notifications

Lot 22 on DP 850117 Schedule 1: One Notification listing Christopher and Lynne Lawlor as Joint Tenants Schedule 2: Four Notifications including one notification for reservations and conditions in the crown grant(s); one notification for easement to drain water 1m appurtenant to the land; one for mortgage to Suncorp-Metway Limited; and one notification as caveat by Jencarling Nominees Pty Ltd.

Lot 25 on DP13137 Schedule 1: One Notification listing James John Cremona Schedule 2: Three Notifications including one notification for reservations and conditions in the crown grant(s); one notification on as a covenant, and one one notification as caveat by Jencarling Nominees Pty Ltd.

Page 12: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 7 of 14

Lot 26 on DP 13137 Schedule 1: One Notification listing Christopher and Lynne Lawlor as Joint Tenants Schedule 2: Three Notifications including one notification for reservations and conditions in the crown grant(s); one notification on as a covenant, and one one notification as caveat by Jencarling Nominees Pty Ltd.

Table 4-3: Summary of Historical Titles

Lot and Deposited Plan Schedules and Notifications

Lot 22 on DP 850117 There are numerous cancelled historical titles associated with this Lot and DP. It appears this Lot and DP was first conveyed in 1949 to Alfred Bell from a larger parcel of land first conveyed to Joseph Bigg in 1815. The site use was presumably residential since at least 1949. This Lot and DP were transferred to other various private individuals since1949 presumably for continued low density residential use.

Lot 25 on DP13137 There are numerous cancelled historical titles associated with this Lot and DP. It appears this Lot and DP was first conveyed in 1972 to Doreen Zillah from a larger parcel of land first conveyed to Joseph Bigg in 1815. The site use was presumably residential since at least 1972. This Lot and DP were transferred to other various private individuals since1972 presumably for continued low density residential use.

Lot 26 on DP 13137 There are numerous cancelled historical titles associated with this Lot and DP. It appears this Lot and DP was first conveyed in 1949 to William Bell from a larger parcel of land first conveyed to Joseph Bigg in 1815. The site use was presumably residential since at least 1949. This Lot and DP were transferred to other various private individuals since 1949 presumably for continued low density residential use.

Copies of title documents are provided in Appendix D.

4.2 Historical Aerial Photograph Review

Aerial photographs of the site for the years 1956, 1970 and 1994 were sourced from the NSW Land and

Property Management Authority, a 2009 photograph was sourced from Google Earth, and a 2014

photograph was sourced from NSW Land and Property Six Maps viewer. A summary of the photographs is

provided in Table 4-4, below. Aerial photograph extract images are presented in Appendix E.

Table 4-4 Summary of Historical Aerial Photographs

Aerial Photograph Description

1956 Black and White

The site appears cleared of some native vegetation but there are trees present in the central portion of the site. A low density residential dwelling is noted at the eastern boundary of the site. Most of the site appears unused/open vegetation but there are gardens and/or small orchid noted in the northern portion of the site. Surrounding areas are also cleared of native vegetation with some trees remaining and appear to be used for residential and/or farming/agricultural purposes.

1970 Black and White

The site development is consistent with the 1955 aerial photograph but there is an additional residence located in the northwest corner of the property. The gardens/orchids are no longer present on the site. The vicinity land use is consistent with the 1955 photograph with increased low density residential land use noted to the northwest.

1994 Colour

The site has been developed since the 1970 aerial photograph and is consistent with the current configuration. The site includes three low density residential dwellings and what appears to be a large shed or stable. A track is apparent in the western portion of the site which may be used for horse riding. Most of the site is cleared of vegetation but some trees are still present around the site. The vicinity land use is consistent with the 1970 aerial photograph with increased low density residential development noted in all directions.

2009 Colour

The site and vicinity development is consistent with the 1994 aerial photograph, except there is increased low density residential development noted.

2014 (Figure 2) Colour

The site and vicinity development is consistent with the 2009 aerial photograph.

Page 13: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 8 of 14

4.3 Contaminated Land Record Review

The NSW EPA environmental register for contaminated land records was accessed online on 20 May 2015

(http://www.epa.nsw.gov.au/prclmapp/sitedetails.aspx). No notices or declarations were listed for the site. A

copy of the search results is included in Appendix F.

4.4 Relevant Planning Information

The planning certificates, issued under Section 149(2) of the Environmental Planning and Assessment Act,

1979, was obtained from Blacktown City Council for each Lot and DP comprising the site. A review of the

Section 149 Planning Certificates indicates the following for all three Lots and DPs:

Land Use Zone – R3 Medium Density (Residential Blacktown Local Environment Plan 1988 and NSW

Government’s Blacktown City Council Growth Centre Precincts Development Control Plan 2010);

The site does not include critical habitat;

The site is not located within a conservation area;

An item of environmental heritage is not listed as being situated on the land;

The land is not affected by the operation of sections 38 or 39 of the Coastal Protection Act 1979, to

the extent that council has been so notified by the Department of Services, Technology and

Administration;

The land is not proclaimed to be a mine subsidence district within the meaning of section 15 of the

Mine Subsidence Compensation Action 1961;

The site is not shown as being subject to tidal inundation;

The site is not shown as being subject to subsidence;

The site is not shown as being subject to flood related development controls;

The site is not within a known acid sulfate soil area; and

Matters arising under the Contaminated Land Management Act, 1997 – Not applicable.

A review of the s149s indicates that the site has not been identified as significantly contaminated. A copy of

the planning certificates are provided in Appendix G.

4.5 Acid Sulphate Soil

A review of the NSW Department of Land and Water Conservation Acid Sulfate Soil Risk Maps shows the

site to be located outside of areas of known Acid Sulfate Soil (ASS). In addition, a review of the maps

provided online by the Australian Soil Resource Information System (ASRIS) shows the site to have a low

probability of occurrence for ASS.

Page 14: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 9 of 14

4.6 Saline Soils

Saline soils are produced when salts stored in the soil profile are mobilised by the movement of water

through evaporation or accumulation. These processes can cause an increase in salt levels to the extent that

vegetation and building materials such as concrete and steel are affected. Highly saline soils can be

aggressive to building foundations and/or preclude the establishment of some types of vegetation. Therefore,

it is important to determine the potential of saline soils at a re-development site.

The BCC DCP 2014 - Schedule Two for the Riverstone Precinct indicates that the north-eastern and south-

western corners of the site may be within an area of potentially higher salinity soils. An overlay of the

information from the Department of Infrastructure Planning and Natural Resources: Salinity Potential in

Western Sydney (Map: 2002) onto current aerial photographs indicates the site is within an area of moderate

potential for saline soils. The BCC map does not indicate that the site is located with an area of known

aggressive saline soils.

If site specific soil salinity information is required, a subsurface investigation should be completed with the

collection of soil samples for indications of salinity. This is typically undertaken as part of a Geotechnical

Investigation. If the data indicates highly saline and/or aggressive soils, the data should be reviewed by

appropriately qualified structural and geotechnical engineers to ensure the structural design of the proposed

development takes into account any potentially aggressive soils which may exist at the site. The design of

any building structural components should be completed in accordance with Australian Standard AS 2159-

2009 Piling: Design and Installation. This standard includes tables on exposure classification of soils and

groundwater based on their aggressiveness to concrete and steel.

4.7 Dangerous Goods Search

A search of the Stored Chemical Information Data Base (SCID) and the microfiche records held by

WorkCover NSW for the site was requested on 5 May 2015. A search of the SCID and the microfiche

records held by WorkCover NSW has not located any records pertaining to the site. The results of the

dangerous goods search are provided in Appendix H.

4.8 Historical Environmental Investigations

TRACE Environmental is not aware of any previous environmental investigations that have been conducted

at the site.

Page 15: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 10 of 14

5 Initial Conceptual Site Model

The environmental risk assessment is based on a contaminant (source) - exposure pathway - receptor

methodology. This relationship allows an assessment of potential environmental risk to be determined, in

accordance with the current national guidelines. Central to the requirements for the assessment of risk is the

development of an initial conceptual site model (CSM), identifying each contaminant source and the

associated receptor exposures.

Generally, a CSM provides an assessment of the fate and transport of contaminants of potential concern

(COPCs) relative to site-specific subsurface conditions with regard to their of potential risk to human health

and the environment. The CSM takes into account site specific factors including:

Sources of potential subsurface impacts;

Identification of potential COPCs derived from the possible sources identified;

Vertical and lateral distribution of potential COPCs;

Site specific lithologic information including soil type(s), depth to groundwater, effective porosity, and

groundwater flow velocity; and

Actual or potential receptors focusing on future and current land use both of the site and adjacent

properties and sensitive ecological receptors.

Based on the information sourced in this PSI, a preliminary CSM has been developed and is outlined in

Table 5-1, below. Additional details are included in the sections that follow as necessary.

Table 5-1: Preliminary Conceptual Site Model

Conceptual Site Model Element

Description

Site History/Contaminant Sources

According to historical information, the site was cleared of natural vegetation and utilised for low density residential purposes as early 1949 and likely earlier. It appears that small scale agriculture use occurred on-site from 1955 to sometime before 1970. Based on the aerial photographs and historical titles, it appears the site has been used for low density residential land use since at least 1949 to the present. The results of this PSI do not indicate any significant potential sources of subsurface impacts resulting from historical land uses.

Site Current and Future Use The site is currently occupied and used primarily for low residential land use. It is proposed to redevelop the site for medium density residential land use.

Site Geology Site specific geological information is not known at this time. According to geological maps, the site is underlain by shale and sandstone. Consistent with the lithology of surrounding sites, a layer of unconsolidated, weather bedrock (overburden) likely exists above the bedrock. The thickness of the overburden and the depth to the bedrock at the site is unknown.

Site Hydrogeology Groundwater may be present within the pore spaces of the overburden material and/or in the underlying bedrock. The site specific hydrogeological conditions are not known at this time. However, regional groundwater likely flows to the west toward Eastern Creek with localised gradients in various directions.

COPCs – Soil There are no known historical releases, or evidence of any significant potential sources of subsurface impact identified. Therefore, no COPCs have been identified for soil.

COPCs – Groundwater There are no known historical releases, or evidence of any significant potential sources of subsurface impact identified. Therefore, no COPCs have been identified for groundwater.

Page 16: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 11 of 14

Conceptual Site Model Element

Description

COPCs – Soil Vapour There are no known historical releases, or evidence of any significant potential sources of subsurface impact identified. Therefore, no COPCs have been identified for soil vapour.

Extent of Impacts – Soil None identified

Extent of Impacts - Groundwater

None identified

Extent of Impacts – Soil Vapour None identified

Potential Human Receptors Current potential human receptors include:

Site residents (dermal exposure, inhalation, ingestion);

Site Visitors (dermal exposure, inhalation, ingestion); and

Adjacent Residents (dermal exposure, inhalation, ingestion). Future potential human receptors include:

Construction Workers (dermal exposure, inhalation, ingestion);

Site Residents (dermal exposure, inhalation, ingestion); and

Adjacent Residents (dermal exposure, inhalation, ingestion).

Potential Environmental Receptors

Eastern Creek is located between 1 and 1.2km west, northwest and southwest of the site. Eastern Creek appears to flow toward the north, and eventually discharges to the Hawkesbury River located approximately 11.5km north of the site.

5.1 Preliminary CSM Summary and Risk Assessment

Historical information indicates the site was cleared prior to the 1950s and was utilised for low density

residential land use, small scale agriculture and potentially horse rearing/riding since at least 1949. The

results of the PSI did not indicate any significant potential sources of sub-surface impacts resulting from the

historic land uses. The overall environmental sensitivity and risk at the site is deemed low based on the

preliminary CSM. No evidence of any significant importation of fill material was identified at the site.

Regardless, any soil requiring removal from the site for development purposes should be classified in

accordance with the NSW EPA Waste Classification Guidelines. Any soil imported to the site for construction

and/or landscaping purposes should be validated as suitable for the proposed land use.

5.2 Data Gaps and Uncertainties

No significant data gaps have been identified that impact the conclusions or recommendations of this PSI.

Page 17: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 12 of 14

6 Conclusions and Recommendations

6.1 Conclusions

Based on the findings of this PSI, the following is concluded:

The site has been used for low density residential land use purposes since at least 1955. Also, small

scale agricultural activities and horse rearing/riding has occurred on the site historically. The site was

developed in its current configuration between approximately 1970 and 1994;

The site land use is currently low density residential;

It is proposed to redevelop the site with approximately ten low-rise apartment buildings;

The results of the historic searches and site inspection undertaken did not indicate a high potential for

contaminating activities to have occurred at the site historically;

The site is located in a low sensitivity environmental setting based on the preliminary Conceptual Site

Model (CSM) developed, and nearby land uses;

The site is not located in an area of known acid sulphate soils; and

The BCC DCP 2014 - Schedule Two for the Riverstone Precinct indicates that the north-eastern and

south-western corners of the site may be located within a region of higher salinity soils. An overlay of

the information from the Department of Infrastructure Planning and Natural Resources: Salinity

Potential in Western Sydney (Map: 2002) onto current aerial photographs indicates the site is within

an area of moderate potential for saline soils. The BCC map does not indicate that the site is located

with an area of known aggressive saline soils.

6.2 Recommendations

Based on the results of the PSI, there is considered to be a low potential for contamination to have occurred

at the site as a result of the current and historic agricultural and residential land uses of the property, and the

site is considered suitable for the proposed medium density residential redevelopment. In view of this, a

Detailed Site Investigation (DSI) is not considered necessary prior to the proposed residential redevelopment

of the site.

In the event that soil is excavated and requires off-site disposal during redevelopment, the soil should be

tested and classified in accordance with NSW EPA guidelines prior to disposal. Any imported material

brought onto the site, to achieve construction levels or for landscaping purposes, must be validated as being

suitable for the proposed residential land use.

If site specific soil salinity information is required, a subsurface investigation should be completed with the

collection of soil samples for indications of salinity. This is typically undertaken as part of a Geotechnical

Investigation. If the data indicates highly saline and/or aggressive soils, the data should be reviewed by

appropriately qualified structural and geotechnical engineers to ensure the structural design of the proposed

development takes into account any potentially aggressive soils which may exist at the site. The design of

any building structural components should be completed in accordance with Australian Standard AS 2159-

2009 Piling: Design and Installation. This standard includes tables on exposure classification of soils and

groundwater based on their aggressiveness to concrete and steel.

Page 18: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 13 of 14

7 References

Australian Standard 4482.1-2005: Guide to the Investigation and Sampling of Potentially

Contaminated Soil – Part 1: Non-volatile and semi-volatile compounds, Standards Australia.

Australian Standard 4482.2-1999: Guide to the Investigation and Sampling of Potentially

Contaminated Soil – Part 2: Volatile Substances, Standards Australia.

National Environment Protection (Assessment of Site Contamination) Amendment Measure 2013 (No.

1), National Environment Protection Council, Canberra.

NSW DEC (2006) Guidelines for the NSW Site Auditor Scheme 2nd Edition.

NSW DECC (2009) Guidelines on the Duty to Report Contamination under the Contaminated Land

Management Act. NSW Department of Environment and Climate Change.

NSW OEH (2011) Contaminated Sites: Guidelines for Consultants Reporting on Contaminated Sites.

NSW Environment Protection Authority.

Page 19: Preliminary Site Investigation

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

The Property Investors Alliance Page 14 of 14

8 Limitations

This report has been prepared for The Property Investors Alliance and for the specific purpose to which it

refers. No responsibility is accepted to any third party and neither the whole of the report or any part or

reference thereto may be published in any document, statement or circular nor in any communication with

third parties without our prior written approval of the form and context in which it will appear.

TRACE Environmental has used a degree of skill and care ordinarily exercised by reputable members of our

profession practicing in the same or similar locality. The conclusions presented in this report are relevant to

the conditions of the site and the state of legislation currently enacted as at the date of this report. We do not

make any representation or warranty that the conclusions in this report were applicable in the future as there

may be changes in the condition of the site, applicable legislation or other factors that would affect the

conclusions contained in this report.

This report and the information contained in it is the intellectual property of The Property Investors Alliance is

granted an exclusive licence for the use of the report for the purpose described in the report.

Page 20: Preliminary Site Investigation

Figures

Page 21: Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

Title:

Address:

Project:

Figure:

Locality Plan 2.13- Junction Road PSI

1

Source: Map Data 2014 Google

42-66 Junction Road, Schofields, NSW

Page 22: Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

Title:

Address:

Project:

Figure:

Site Plan 2.13-Junction Road PSI 2

Source: NSW Six Viewer

42-66 Junction Road

Page 23: Preliminary Site Investigation

Appendix A

Site Survey

Page 24: Preliminary Site Investigation

E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD E D

BY

D E DB

YD

E

DBYD

E

DBYD

E DB

YD E D

BY

D

T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD

O DB

YD O D

BY

D O DB

YD O D

BY

D O DB

YD O D

BY

D O DB

YD O D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D T DB

YD T D

BY

D

T DB

YD

W DB

YD W D

BY

D W DB

YD W D

BY

D W DB

YD W D

BY

D W DB

YD W D

BY

D W DB

YD W D

BY

D W DB

YD W D

BY

D W DB

YD W D

BY

D W DB

YD W D

BY

D W DB

YD

W DB

YD W D

BY

D W DB

YD W D

BY

D W DB

YD W D

BY

D W DB

YD

T DB

YD

W DB

YD

E DB

YD

O DB

YD O D

BY

D O DB

YD O D

BY

D O DB

YD O D

BY

D O DB

YD O D

BY

D O DB

YD O D

BY

D O DB

YD O D

BY

D O DB

YD O D

BY

D O DB

YD O D

BY

D O DB

YD O D

BY

D O DB

YD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O

DBYD

O DB

YD O D

BY

D O DB

YD

PPLPTC

SSSS

SS PP

SV

HYD HYD PPLPPP

PP HYD TCWM

WM

PIT

PLP PP

OPTUS PIT

HYDPPLP

LP

PIT

25D.P. 13137

GRASS'A'

22D.P. 850117

GRASS

PO

ST

&W

IRE

FEN

CE

GRASS

POST & WIRE FENCE

CH

AIN

WIR

EFE

NC

E

PA

LIN

GFE

NC

ETI

MB

ER

FEN

CE

SEPTIC TANK

POST & WIRE FENCE

PA

LIN

GFE

NC

E

BRICK DWELLINGTILE ROOFNo.66

GRASS

CHAIN WIRE FENCE

GRASS

CONCRETE

FIBRO SHED

CONCRETEPATH

VERANDAHAWNING

CONCRETEPATH

TIM

BE

RFE

NC

E

CONCRETEDRIVEWAY

TIMBER FENCE

TIMBER

FENC

E

METAL

FENCE

CARPORT

BRICK DWELLINGTILE ROOF

No.64

METAL

PP

WMFENCE

CONCRETEDRIVEWAY

ME

TAL

FEN

CE

TIM

BE

RFE

NC

E

GRAVELDRIVEWAY

TIMBER FENCE

TIMBER FENCE

GRASS

TIM

BE

RFE

NC

E

TIMBER FENCE

CONCRETE BLOCKSTABLES

TIMBER FENCE

TIMBERRETAINING WALL

CO

NC

RE

TE

POOL

POST & WIREFENCE

METAL FENCE

ME

TAL

FEN

CE

PO

ST

&W

IRE

FEN

CE

26D.P. 13137

PO

ST

&W

IRE

FEN

CE

GRASS

CH

AIN

WIR

EFE

NC

E

CHAIN WIRE FENCEC

HA

INW

IRE

FEN

CE

CONCRETEBLOCKDOG KENNEL

PO

ST

&W

IRE

FEN

CE

POST & WIRE FENCE

POST FENCE& WIRE

POST

&

WIRE

FENCE

GRAVELDRIVEWAY

GRAVELDRIVEWAY

STR

EET

AD

VA

NC

EJUNCTION ROAD

WEATHERBOARDDWELLINGMETAL ROOFNo.42

STAIRS

CONCRETEDRIVEWAY

GRAVELDRIVEWAY

ME

TAL

FEN

CE

GRASS

METALSHED

SEPTICTANK

POOL SHED

STAIRS

ME

TAL

FEN

CE

GRAVELDRIVEWAYGRASS

EDGE OF BITUMEN EDGE OF BITUMEN

GRASS

EDGE OF BITUMENEDGE OF BITUMEN

BITUMENDRIVEWAY

CONCRETE KERB & GUTTER

METAL FENCE

GPTC

STAIRS

STAIRS

CONCRETEDRIVEWAYBITUMEN

DRIVEWAY

GRASSGRASSBM PM 57336R.L. 38.717 (A.H.D.)

BITUMENDRIVEWAY

TELECOMMUNICATIONS PIT

TREE

AHD AUSTRALIAN HEIGHT DATUM

RL REDUCED LEVEL

BENCH MARK

8/.5

WATER METER

POWER POLE

LEGEND

BM

TC

WM

PPLP POWER POLE/LIGHT POLE

PP

SS STREET SIGN

STOP VALVESV

SS STREET SIGN

PIT TELECOMMUNICATIONS PIT

HYD HYDRANT

LP LIGHT POLE

GP GULLY PIT

FENCE

TOP OF BANK

GATE

'A' - EASEMENT TO DRAIN WATER 1 WIDE VIDE D.P. 850117(LOT 22 D.P. 850117 BENEFITS)

OF B

ANK

BTM BOTTOM

BTM

OF BANK

BTM

OF

BANK

BTM

OF

BAN

K

BTM

OVERHEAD POWERLINE

EASEMENT

30.5

30.5

3131.5

32

32

32.5

32.5

32.5

33

33

33

33

33

33.5

33.5

33.5

33.5

34

34

34

34

34.5

34.5

34.5

35

35.5

35.5

36

36

36.5

36.5

37

37.5

37.5

37.5

38

38.5

39

39.5

39.5

40

40

39

31.5

31

37

32.5

APPROXIMATE LOCATION OF UNDERGROUND WATER MAIN VIDE DBYDAPPROXIMATE LOCATION OF UNDERGROUND TELSTRA CABLES VIDE DBYD

M.G.A.T.N.

1°10'40"

MOUND

MOUND

APPROXIMATE LOCATION OF UNDERGROUND ELECTRICITY CABLES VIDE DBYDAPPROXIMATE LOCATION OF UNDERGROUND OPTUS CABLES VIDE DBYDO D

BY

D

OPTUS PIT

OPTUSMARKER

A1A B C D E F G H I J K L M N O P

12

34

56

78

910

11

Proj.Man.

Council Ref.

L.G.A.

Drawn.

Date

Calc's

Principal:

Datum

Scale

Project:

Dwg File Ref. [Rev] - Sheet Ref.

OurRef.

Client Ref:© Craig & Rhodes

ACN 050 209 991DX 4408 EPPING

Tel. 9869-1855Fax. 9869-2341

[email protected]

ABN 77 050 209 991Level 4, Suite 40016-18 Cambridge StEPPING NSW 2121PO Box 233EPPING NSW 1710

085-14

085-14G T01 [01] - PLAN

PIA 1:500

13/03/2015

A.H.D. / M.G.A. BLACKTOWN

L.H A.P A.H

Survey Notes:-Location of structures approximate only.

The levels and details on this plan have been determined by stadiamethods and are within the general accepted accuracies for suchsurveys. All set out levels must be referred to the bench mark.

Bearings and Distances are by deed only and are subject to FinalSurvey. Except where shown by dimension, the relationship ofimprovements to boundaries is diagrammatic only. The truepositions are subject to Final Survey.

Tree sizes are estimates and indicative only.

Services and utilities shown have been located by physicalevidence and/or by reference to service plans from the relevantauthorities. Subsurface utility information shown in accordancewith AS5488-2013 QL-D. Pits may not have been opened to verifythe type of utility. Excavation has not been carried out to confirmunderground location. Service details should be confirmed with therelevant service authority during design and prior tocommencement of construction.

As part of your duty of care, please contact the following wherenecessary :-

Ausgrid Ph. 131535Dial Before You Dig Ph. 1100Endeavour Energy Ph. 131081Jemena Gas Company Ph. 131245NBN Ph. 1800 881 816Optus Communications Ph. 1800 505 777Sydney Water Ph. 132092Telstra Corporation Ph. 132203

This plan has been prepared for the exclusive use of the principalas listed in the title block.

Any construction on or near the boundaries will require furthersurvey so that marks defining boundaries can be placed.

All set out levels must be referred to the bench mark.

© Copyright Craig & Rhodes Pty. Ltd. 2014.

No part of this survey may be reproduced, stored in a retrievalsystem or transmitted in any form without the express permissionof the copyright owner except as permitted under the Copyright Act1968.

Any permitted downloading, electronic storage, display, print, copyor reproduction of this survey should contain no alteration oraddition to the original.

These notes must not be erased.

ORIGIN OF LEVELS: S.S.M. 57336 RL. 38.717 (A.H.D.) VIDE SCIMS DATED 14/01/2014

AMEND. No.: DATE: DETAILS:01 18/03/2015 UNDERGROUND SERVICES ADDED, TRUE NORTH CONVERGENCE

BOUNDARY BEARINGS TO M.G.A.

Page 25: Preliminary Site Investigation

Appendix B

Site Photographs

Page 26: Preliminary Site Investigation

Photograph 2: One storey residence at 62 Junction Road with bitumen driveway providing access

Photograph 1: One storey residence at 42 Junction Road with bitumen driveway providing access.

Appendix B: Photographic Log

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

Page 27: Preliminary Site Investigation

Photograph 4: Pool located behind 42 Junction Road residence that appears unused recently.

Photograph 3: One storey residence located at 66 Junction Road with unsealed driveway providing access.

Appendix B: Photographic Log

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

Page 28: Preliminary Site Investigation

Photograph 6: Metal fencing separating the lots the

comprise the site.

Photograph 5: Small unused metal sheds at 42 Junction Road property.

Appendix B: Photographic Log

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

Page 29: Preliminary Site Investigation

Photograph 8: Former stable with outer walls covered in graffiti.

Photograph 7: Wooden fence that separate the lots the comprise the site.

Appendix B: Photographic Log

Preliminary Site Investigation

42-66 Junction Road, Schofields, NSW

Page 30: Preliminary Site Investigation

Photograph 9: Much of the site is unsealed, vegetated land with some trees.

Appendix B: Photographic Log

Preliminary/Site Investigation

42-66 Junction Road, Schofields, NSW

Page 31: Preliminary Site Investigation

Appendix C

Dial Before You Dig Plans

Page 32: Preliminary Site Investigation

WARNING: This document is confidential and may also be privileged. Confidentiality nor privilege is not waived or destroyed by virtue of it being transmitted to an incorrect addressee. Unauthorised use of the contents is therefore strictly prohibited. Any information contained in this document that has been extracted from our records is believed to be accurate, but no responsibility is assumed for any error or omission.Optus Plans and information supplied are valid for 30 days from the date of issue. If this timeline has elapsed please raise a new enquiry.

Sequence Number: Date Generated:

For all Optus DBYD plan enquiries –Email: [email protected] urgent onsite assistance contact 1800 505 777Optus Limited ACN 052 833 208

20/05/201545631306

Page 33: Preliminary Site Investigation

Seq. No. Authority Name Phone Status45631304 Endeavour Energy 0298534161 NOTIFIED45631307 Jemena Gas West 1300880906 NOTIFIED45631309 NBN Co, NswAct 1800626762 NOTIFIED45631306 Optus and/or Uecomm, Nsw 1800505777 NOTIFIED45631308 Sydney Water 132092 NOTIFIED45631305 Telstra NSW, Central 1800653935 NOTIFIED

END OF UTILITIES LIST

Phone: 1100www.1100.com.au

Dig Site and Enquiry Details

Caller Details

Asset Owner Details

WARNING: The map below only displays the location of the proposed dig site and does not display any asset owners' pipe or cables. The area highlighted has been used only to identify the participating asset owners, who will send information to you directly.

● Check that the location of the dig site is correct. If not you must submit a new enquiry. ● Should the scope of works change, or plan validity dates expire, you must submit a new enquiry. ● Do NOT dig without plans. Safe excavation is your responsibility. If you do not understand the plans or how to proceed safely, please contact the relevant asset owners.

Your Responsibilities and Duty of Care● If plans are not received within 2 working days, contact the asset owners directly & quote their Sequence No.● ALWAYS perform an onsite inspection for the presence of assets. Should you require an onsite location, contact the asset owners directly. Please remember, plans do not detail the exact location of assets.● Pothole to establish the exact location of all underground assets using a hand shovel, before using heavy machinery.● Ensure you adhere to any State legislative requirements regarding Duty of Care and safe digging requirements.● If you damage an underground asset you MUST advise the asset owner immediately.● By using this service, you agree to Privacy Policy and the terms and disclaimers set out at www.1100.com.au● For more information on safe excavation practices, visit www.1100.com.au

The assets owners listed below have been requested to contact you with information about their asset locations within 2 working days.Additional time should be allowed for information issued by post. It is your responsibility to identify the presence of any underground assets in and around your proposed dig site. Please be aware, that not all asset owners are registered with the Dial Before You Dig service, so it is your responsibility to identify and contact any asset owners not listed here directly.** Asset owners highlighted by asterisks ** require that you visit their offices to collect plans.# Asset owners highlighted with a hash require that you call them to discuss your enquiry or to obtain plans.

Lodge Your Free Enquiry Online – 24 Hours a Day, Seven Days a Week

Contact:Company: Mobile: Fax:

Email:

Caller Id:

Address:

User Reference:

Job Purpose:

Enquiry Date:

Working on Behalf of:

Start Date:

Onsite Activity:

Location in Road:

Phone:

End Date:

Address:

Location of Workplace:

Notes/Description of Works:

23/05/2015

Both

31/05/2015

Job No 9199117

04278567901460255

Surry Hills NSW 2010

Schofields NSW 276242-66 Junction Road

Not Supplied

Private

Planning & Design

Not Supplied

124 Chalmers Street

CarriageWay,Footpath,Nature Strip

Design

Junction Road PSI

20/05/2015

[email protected]

Mr Matthew TendamTRACE Environmental

Page 34: Preliminary Site Investigation
Page 35: Preliminary Site Investigation
Page 36: Preliminary Site Investigation

Appendix D

Current and Historical Titles

Page 37: Preliminary Site Investigation
Page 38: Preliminary Site Investigation
Page 39: Preliminary Site Investigation
Page 40: Preliminary Site Investigation
Page 41: Preliminary Site Investigation
Page 42: Preliminary Site Investigation
Page 43: Preliminary Site Investigation
Page 44: Preliminary Site Investigation
Page 45: Preliminary Site Investigation
Page 46: Preliminary Site Investigation
Page 47: Preliminary Site Investigation
Page 48: Preliminary Site Investigation
Page 49: Preliminary Site Investigation
Page 50: Preliminary Site Investigation
Page 51: Preliminary Site Investigation
Page 52: Preliminary Site Investigation
Page 53: Preliminary Site Investigation
Page 54: Preliminary Site Investigation
Page 55: Preliminary Site Investigation
Page 56: Preliminary Site Investigation
Page 57: Preliminary Site Investigation
Page 58: Preliminary Site Investigation
Page 59: Preliminary Site Investigation
Page 60: Preliminary Site Investigation
Page 61: Preliminary Site Investigation
Page 62: Preliminary Site Investigation
Page 63: Preliminary Site Investigation
Page 64: Preliminary Site Investigation
Page 65: Preliminary Site Investigation
Page 66: Preliminary Site Investigation
Page 67: Preliminary Site Investigation

Appendix E

Historical Aerial Photographs

Page 68: Preliminary Site Investigation

1956 Aerial Photograph

Appendix E: Aerial Photographs

Preliminary/Detailed Site Investigation

30-32 Advance Street, Schofields, NSW

Page 69: Preliminary Site Investigation

1970 Aerial Photograph

Appendix E: Aerial Photographs

Preliminary/Detailed Site Investigation

30-32 Advance Street, Schofields, NSW

Page 70: Preliminary Site Investigation

1994 Aerial Photograph

Appendix E: Aerial Photographs

Preliminary/Detailed Site Investigation

30-32 Advance Street, Schofields, NSW

Page 71: Preliminary Site Investigation

2009 Aerial Photograph

Appendix E: Aerial Photographs

Preliminary/Detailed Site Investigation

30-32 Advance Street, Schofields, NSW

Page 72: Preliminary Site Investigation

Appendix F

EPA Records Search Results

Page 73: Preliminary Site Investigation

5/20/2015 DECCW | Search results

http://www.epa.nsw.gov.au/prclmapp/searchresults.aspx?&LGA=0750&Suburb=&Notice=&Name=&Text=&DateFrom=&DateTo= 1/1

Connect

 

Feedback

Web supportPublic consultation

Contact

Contact usOfficesReport pollution

Government

NSW Governmentjobs.nsw

About

AccessibilityDisclaimerPrivacyCopyright

Healthy Environment, Healthy Community, Healthy Business

Home  >  Contaminated land  >  Record of notices

Search resultsYour search for:LGA: Blacktown City Council   Matched 7 notices relating

to 2 sites.Search Again    Refine Search

Suburb Address Site Name Noticesrelated tothis site

Kings Park 21 Tattersall Road Former Dow Corning Sealants Factory1 current and4 former

Seven Hills 27 Powers Road Ma­Refine Oils Seven Hills 2 current

Page 1 of 1

20 May 2015

 

Page 74: Preliminary Site Investigation

Appendix G

Planning Certificates

Page 75: Preliminary Site Investigation
Page 76: Preliminary Site Investigation
Page 77: Preliminary Site Investigation
Page 78: Preliminary Site Investigation
Page 79: Preliminary Site Investigation
Page 80: Preliminary Site Investigation
Page 81: Preliminary Site Investigation
Page 82: Preliminary Site Investigation
Page 83: Preliminary Site Investigation
Page 84: Preliminary Site Investigation
Page 85: Preliminary Site Investigation
Page 86: Preliminary Site Investigation
Page 87: Preliminary Site Investigation
Page 88: Preliminary Site Investigation
Page 89: Preliminary Site Investigation
Page 90: Preliminary Site Investigation
Page 91: Preliminary Site Investigation
Page 92: Preliminary Site Investigation
Page 93: Preliminary Site Investigation
Page 94: Preliminary Site Investigation
Page 95: Preliminary Site Investigation
Page 96: Preliminary Site Investigation
Page 97: Preliminary Site Investigation
Page 98: Preliminary Site Investigation
Page 99: Preliminary Site Investigation
Page 100: Preliminary Site Investigation
Page 101: Preliminary Site Investigation
Page 102: Preliminary Site Investigation
Page 103: Preliminary Site Investigation
Page 104: Preliminary Site Investigation
Page 105: Preliminary Site Investigation
Page 106: Preliminary Site Investigation
Page 107: Preliminary Site Investigation
Page 108: Preliminary Site Investigation
Page 109: Preliminary Site Investigation
Page 110: Preliminary Site Investigation
Page 111: Preliminary Site Investigation
Page 112: Preliminary Site Investigation

Appendix H

Dangerous Goods Search Results

Page 113: Preliminary Site Investigation