OPTIMIZACIJA VODOVODNOG SISTEMA GRAČANICA
SMANJENJEM NEOBRAČUNATE VODE
PROVOĐENJEM RAZNIH MJERA I AKTIVNOSTI KAO I
UVOĐENJEM AUTOMATSKE REGULACIJE PRITISKA
U DISTRIBUTIVNOJ MREŽI
– ISKUSTVA IZ PRAKSE -
Mulabdić Jasmin, dipl.inž.građ.
JP „VODOVOD I KANALIZACIJA” GRAČANICA
NEOBRAČUNATA VODA
VAŽAN FAKTOR U GOSPODARENJU VODOM SU GUBICI U
DISTRIBICIJI VODE U VODOVODNIM SISTEMIMA,
UPRAVLJANJE GUBICIMA U PROCESU ODRŽAVANJA VODOVNIH
SISTEMA JE IZUZETNO SLOŽEN I VISOKO STRUČAN POSAO,
NEOBRAČUNATA / NEPRIHODOVANA VODA – RAZLIKA IZMEĐU
PROIZVEDENE I PRODANE / FAKTURISANE KOLIČINE VODE,
IWA BILANSA VODE :
NEOBRAČUNATA VODA
GUBICI U VODOVODNIM SISTEMIMA
STVARNI GUBICI VODE (CARL),
NEIZBJEŽNI GUBICI VODE (UARL), PRORAČUNAVA SE NA OSNOVU
DUŽINE MREŽE, BROJA PRIKLJUČAKA I PROSJEČNOG PRITISKA U
MREŽI,
INDIKATOR USPJEŠNOSTI RJEŠAVANJA PROBLEMA STVARNIH
GUBITAKA VODE – „ILI” INDIKATOR,
„ILI” INDIKATOR – PREDSTAVLJA ODNOS IZMEĐU CARL / UARL
REALAN INDIKATOR KOJIM MOŽEMO UPOREĐIVATI NPR.
RAVNIČARKE I BRDSKE VODOVODNE SISTEME
STANJE U BOSNI I HERCEGOVINI:
GUBICI VODE ODNOSNO NEOBRAČUNATA VODA U NAŠIM
VODOVODIMA UGLAVNOM SE KREĆU OD 20 DO 70 %,
PREMA ISTRAŽIVANJU UNDP-a U 2011 GODINI NA UZORKU OD 20
OPĆINA U BIH, PROSJEČNI GUBICI - NEOBRAČUNATA VODA IZNOSI
PORAŽAVAJUĆIH 60%,
PITANJE I RJEŠENJE
ZADACI
1. KOLIKI SU GUBICI VODE
-Utvrditi sve komponenete
BILANSA VODE
-Kvaliteta mjerenja i procjena količina
-Kalibracija i kontrola mjerila protoka
- Unapređenje u registraciji mjerenja
2. GDJE SE GUBI VODA
-Utvrditi curenja (količine)
-Proračunati prividne gubitke
AUDIT SISTEMA
-Analiza gubitaka (mjerenje i analiza)
-Analiza sistema (distribucija, potrošnja)
3. ZAŠTO SE GUBI VODA
-Analizirati mrežu i način održavanja
sistema
ANALIZA ODRŽAVANJA SISTEMA
-Istorija gubitaka
-Praksa u rješavanju gubitaka
-Kvaliteta materijala i opreme
-Lokalne specifičnosti
-Socijalni, kulturni i finansiski aspekti
4. KAKO UNAPRIJEDITI UČINKOVITOST
-Unaprijediti sistem
-Kreirati strategiju i plan
UNAPREĐENJA I RAZVOJ STRATEGIJE
-Unapređenje podataka o sistemu
-Uvesti podjelu sistema u zone (DMA)
-Uvesti kontrolu curenja
-Utvrditi uzroke prividnih gubitaka
-Pokrenuti aktivnosti detekcije curenja
-Utvrditi kratkoročne/srednjoročne i
dugoročne planove
5. KAKO ODRŽATI UČINKOVITOST
-Osigurati dugotrajnost i učinkovitost
pravilnim rukovođenjem ljudski m
resursima i organizacijom
PRIMJENA POLITIKE, OBUKA, UPRAVLJANJE I
ODRŽAVANJE
Obuka:
-Unaprijediti znanja
-Povećati motivaciju
-Prijenos vještina
-Primijeniti najbolja iskustva i tehnologije
Upravljanje i održavanje:
-Uključiti širu zajednicu
-Ustanoviti program štednje
-Uvesti procedure
KAKO POČETI SISTEMSKI UPRAVLJATI GUBICIMA?
KAKO POČETI SISTEMSKI UPRAVLJATI GUBICIMA?
1. BEZUSLOVNA ODLUKA UPRAVA PREDZEĆA
2. KRATKOROČNE MJERE
URADITI BILANS VODA (IWA METODOLOGIJA)
AUDIT SISTEMA (Uraditi detaljna mjerenja parametara u sistemu
(protok, pritisak) i izvršiti potrebne analize i sve prikazatI u
odgovarajućem dokumentu)
NABAVKA POTREBNE OPREME ZA DETEKCIJU
FORMIRANJE SLUŽBE/ODJELA ZA GUBITKE
UTVRĐIVANJE ZONA SA NAJVEĆIM CURENJIMA
DETEKCIJA CURENJA I OTKLANJANJE KVAROVA
UTVRĐIVANJE NELEGALNIH POTROŠAČA I KRAĐE VODE
KALIBRACIJA I ZAMJENA VODOMJERA U SISTEMU
3. SREDNJOROČNE MJERE
EDUKACIJA KLJUČNOG I OSTALOG OSOBLJA
UVOĐENJE PODJELE SISTEMA U DMA ZONE
KAKO POČETI SISTEMSKI UPRAVLJATI GUBICIMA?
UVOĐENJE DALJINSKOG NADZORA DISTRIBUTIVNE MREŽE
UVOĐENJE REGULACIJE PRITISKA (DINAMIČKE I FIKSNE)
USPOSTAVA DALJINSKOG NADZORA I UPRAVLJANJA
VODOVODNIM SISTEMOM (SCADA)
IZRADA ILI OSAVREMENJAVANJE GIS-A VODOVODNOG SISTEMA
IZRADA HIDRAULIČKOG MODELA VODOVODNE MREŽE
BENČMARKING U OBLASTI UPRAVLJANJA GUBICIMA
USPOSTAVLJANJE REGISTRA KVAROVA, PROCEDURA I
ODGOVORNOSTI ZA IZVRŠENJE I KONTROLU
PRIMJENA METODOLOGIJE PREVENTIVNOG ODRŽAVANJA
PRIMJENA I W A METODOLOGIJE U ANALIZI GUBITAKA VODE I
PRIMJENE ODGOVARAJUĆIH INDIKATORA
3. DUGOROČNE MJERE
PLANSKA ZAMJENA I REKONSTRUKCIJA DOTRAJALIH CJEVOVODA
(PRIORITET DIONICE SA UTVRĐENIM NAJVEĆIM CURENJIMA)
PLAN REALIZACIJE PROJEKTA SMANJENJA GUBITAKA
NADZOR I KONTROLA DISTRIBUTIVNE MREŽE
VEOMA VAŽNU ULOGU U UPRAVLJANJU GUBICIMA U VODOVODNIM
SISTEMIMA IMA:
PODJELA DISTRIBUTIVNE MREŽE U ZONE (ZONIRANJE MREŽE),
USPOSTAVLJANJE SISTEMA DALJINSKOG NADZORA,
REDOVNO PRAĆENJE I ANALIZA INFORMACIJA.
NADZOR I KONTROLA DISTRIBUTIVNE MREŽE
VAŽNOST OPTIMALNIH PRITISAKA U SISTEMU
PRITISAK U VODOOPSKRBNOM SISTEMU DIREKTNO UTIČE NA
VELIČINU GUBITAKA - RASIPANJA VODE
Grafikon odnosa pritisak - gubitak
(promjer puknuća/otvora: 6 mm)
10.000,00
12.500,00
15.000,00
17.500,00
20.000,00
22.500,00
25.000,00
27.500,00
30.000,00
4 bar 6 bar 8 bar
Pritisak
gu
bit
ak (
m3/g
od
ina)
6
VAŽNOST OPTIMALNIH PRITISAKA U SISTEMU
IWA (MEĐUNARODNO UDRUŽENJE ZA VODE) JE OBJAVILA PODATAK DA
SVE VIŠE ZEMALJA VRŠI PROAKTIVNU KONTROLU PRITISKA U
VODOVODNIM SISTEMIMA,
U POSLEDNJIH 15-TAK GODINA POSTIGNUTI SU ZNAČAJNI REZULTATI U
SVIJETU PRIMJENOM AKTIVNE KONTROLE PRITISKA,
PRITISAK U CJEVOVODIMA VEOMA JE VAŽAN NA FREKVENCIJU POJAVE
NOVIH KVAROVA ALI I NA INTENZITET CURENJA POSTOJEĆIH,
NAROČITO JE VAŽNO SPREČAVANJE OSCILIRAJUĆEG PRITISKA U MREŽI
(HIDRAULIČKI UDARI),
SMANJENJEM PRITISKA U DISTRIBUTIVNOJ MREŽI POSTIŽEMO DIREKTNI
UTICAJ NA SMNJENJE GUBITAKA VODE NA SVIM ELEMNTIMA SISTEMA
(CJEVOVODI, ČVORNA MJESTA, INTERNI SISTEMI POTROŠAČA ITD.)
VENTILI ZA REDUKCIJU PRITISKA
VENTIL SA PROMJENJIVIM IZLAZNIM PRITISKOM
(REDUCIR VENTIL NADOGRAĐEN S AUTOMATIKOM KOJA IMA MOGUĆNOST
IZVRŠAVATI UNAPRIJED PROGRAMIRANE PROMJENE PRITISKA)
VENTIL SA STALNIM IZLAZNIM PRITISKOM
(PRIMJENJUJE SE VEĆ DUŽI NIZ GODINA,
EFEKTI SU DOBRI ALI IZLAZNI PRITISAK
IMA KONSTANTNU VRIJEDNOST)
UREĐAJ ZA REGULACIJU PRITISKA U MREŽI
UPRAVLJAN PREKO NAJVIŠEG POTROŠAČA - REGULO
OPĆINA GRAČANICA
GRAČANICA JE GRAD I OPĆINA KOJA SE NALAZI U SJEVERIOSTOČNOJ BOSNI, U TUZLANSKOM KANTONU,
PO NOVOM POPISU IZ 2013 GODINE U OPĆINI ŽIVI OKO 50.000 STANOVNIKA, A U GRADSKOM PODRUČJU OKO 16.000 STAN.,
POVRŠINA KOJU OPĆINA OBUHVATA IZNOSI 219,5 km2
VODOVODNI SISTEM GRAČANICA
„NULTO STANJE” – 2004 GODINA
PRIJE INTENZIVIRANJA AKTIVNOSTI NA SMANJENJU GUBITAKA
U SISTEMU STANJE JE BILO SLJEDEĆE:
KOMBINOVANI SISTEM VODOSNABDIJEVANJA, 5 PUMPNIH
STANICA SA INSTALISANOM SNAGOM N=90 Kw,
PODRUČJE VODOSNABDIJEVANJA PREKO 18.000 STANOV. I
CJELOKUPNA INDUSTRIJA,
OKO 5.400 PRIKLJUČAKA U SISTEMU DISTRIBUCIJE VODE,
DOMINIRAJU CJEVOVODI OD PEHD-a I PVC-a, A UKUPNA
DUŽINA CJEVOVODA U MREŽI JE OKO 125 km,
IZDAŠNOST POSTOJEĆIH IZVORIŠTA NE ZADOVOLJAVA
POTREBE ZA VODOM,
REDUKCIJE U VODOSNABDIJEVANJU (NOĆNE U
KONTINUITETU, A DNEVNE U SUŠNOM PERIODU GODINE),
GODIŠNJI BROJ KVAROVA U SISTEMU U NEKIM GODINAMA BIO JE I PREKO 600,
VODOVODNI SISTEM GRAČANICA
„NULTO STANJE” – 2004 GODINA
GUBICI U VODOVODNOM SISTEMU – NOBRAČUNATA VODA,
IZNOSILI SU OKO 58% OD UKUPNO PROIZVEDENIH KOLIČINA,
NEZADOVOLJAVAJUĆI STEPEN NAPLATE POTRAŽIVANJA,
USLJED REDUKCIJA U SNABDIJEVANJU I NEMINOVNIH
HIDRAULIČKIH UDARA NASTAJAO JE VELIKI BROJ
KVAROVA U SISTEMU,
NEZADOVOLJSTVO GRAĐANA OPŠTIM STANJEM,
PROSTORNI RASPORED IZVORIŠTA
SPIRALA ESKALACIJE PROBLEMA
GRAČANICA
ULAGANJE U SMANJENJE GUBITAKA JE NAJJEFTINIJI
NAČIN UVOĐENJA NOVIH KOLIČINA VODE U SISTEM
INTENZIVIRANJE „BORBE” SA GUBICIMA NA
SVIM „FRONTOVIMA” - 2005 GODINA
IZRAĐENA JE “ANALIZA VODOVODNOG SISTEMA GRAČANICA”
KOJA JE NA OSNOVU PROVEDENIH MJERENJA (PRITISKA
I PROTOKA) I IZVRŠENIH HIDRAULIČKIH PRORAČUNA POKAZALA
DA PRVA FAZA TREBA DA OBUHVATI:
BALANSIRANJE SISTEMA UVOĐENJEM KONTROLE I
AUTOMATSKE REGULACIJE PRITISKA U SISTEMU,
DALJINSKI NADZOR POTROŠNJE (PROTOKA) I PRITISKA U
SISTEMU FORMIRANJEM DMA ZONA
UTVRĐIVANJE MJESTA PROPUŠTANJA U MREŽI – PRONALAŽENJEM NEVIDLJIVIH CURENJA
STANICA ZA USPOSTAVU AUTOMATSKE
KONTROLE I REGULACIJE PRITISKA
ARMIRANO BETONSKI ŠAHT DIMENZIJA 5,50x3,0x2,0 m SA
UGRAĐENOM SLJEDEĆOM OPREMOM:
DVA HIDRAULIČKA REDUCIR VENTILA DN 150 , “CLA-VAL”,
FAZONSKI KOMADI I ARMATURE (U PRAVCU + BAJPAS)
UREĐAJ ZA AUTOMATSKU REGULACIJU PRITISKA PO VREMENU I
PROTOKU “MODULO” ENGLESKOG PROIZVOĐAČA “TEHNOLOG”
(BATERIJSKI NAPAJAN)
DATA LOGGER “CELLO” PROIZVOĐAČA “TEHNOLOG” SA UGRAĐENOM
GSM KARTICOM ZA PRENOS PODATAKA PUTEM SMS PORUKA
(BATERIJSKI NAPAJAN) – DALJINSKI NADZOR
PUŠTANJE U RAD SISTEMA ODVIJALO SE U
FAZAMA: 1. FIKSNA REGULACIJA: NIZVODNI PRITISAK JE REDUCIRAN ZA 1,5 BARA U
ODNOSU NA STANJE PRIJE REGULACIJE (SA 5,5 NA 4,0 BARA, A U KASNIJOJ FAZI EKSPLATACIJE NA 3,70 bara)
2. VREMENSKA REGULACIJA: ZATIM JE USPOSTAVLJENA AUTOMATSKA REGULACIJA “PO VREMENU” SA DODATNIM SMANJENJEM PRITISKA U NOĆNIM SATIMA ZA DODATNIH 1,0 BARA (SNABDIJEVANJE UREDNO)
3. REGULACIJA PO PROTOKU: OPCIJA REGULACIJE NIZVODNOG PRITISKA “PO PROTOKU” SE ODVIJALA NA OSNOVU PROMJENE NIZVODNE POTROŠNJE
POSTOJI MOGUĆNOST PODEŠAVANJA USLOVIMA U SISTEMU.
NOĆNI PRITISAK JE U GRANICAMA OPTIMALNOG TAKO DA SVI POTROŠAČI IMAJU DOVOLJAN PRITISAK.
PRITISAK U SISTEMU SE RELATIVNO BRZO PRILAGOĐAVA NIZVODNOJ POTROŠNJI ALI NE VEĆI OD UNAPRIJED MAX. DEFINISANOG OD 4,0 BARA
CIJELO VRIJEME UZ POMOĆ DALJINSKOG NADZORA PRATILI SMO PROTOK
I PRITISAK NA REDUCIR STANICI
Vrijednost pritiska na lokaciji reducir stanice prije i poslije
uvođenja sistema automatske regulacije
0,00
1,00
2,00
3,00
4,00
5,00
6,00
12
:00
:00
12
:45
:00
13
:30
:00
14
:15
:00
15
:00
:00
15
:45
:00
16
:30
:00
17
:15
:00
18
:00
:00
18
:45
:00
19
:30
:00
20
:15
:00
21
:00
:00
21
:45
:00
22
:30
:00
23
:15
:00
0:0
0:0
0
0:4
5:0
0
1:3
0:0
0
2:1
5:0
0
3:0
0:0
0
3:4
5:0
0
4:3
0:0
0
5:1
5:0
0
6:0
0:0
0
6:4
5:0
0
7:3
0:0
0
8:1
5:0
0
9:0
0:0
0
9:4
5:0
0
10
:30
:00
11
:15
:00
12
:00
:00
Vrijeme
Pri
tisak (
bar)
Prije uspostavljanja regulacije Poslije uspostavljanja regulacije
EFEKTI UVOĐENJA SISTEMA KONTROLE I
AUTOMATSKE REGULACIJE PRITISKA U VODOVODU
GRAČANICA :
SMANJENJE DNEVNE ISPORUKE VODE ZA 500-700 m3 (12-15 %)
(SMANJENJE GUBITAKA VODE U SISTEMU DO 10%)
SMANJENJE TROŠKOVA EKSPLATACIJE SISTEMA (DO 20 %),
ZNAČAJNO SMANJEN BROJ KVAROVA U SISTEMU ; ZA 50 % (PROSJEČNO MJESEČNO SA 24 NA 12 KVAROVA),
USPOSTAVLJENO KVALITETNO 24-ČASOVNO SNABDIJEVANJE STANOVNIŠTVA I INDUSTRIJE VODOM,
UMANJENA MOGUĆNOST POJAVE HIDRAULIČKIH UDARA I STVORENI OPTIMALNI USLOVI RADA SISTEMA,
PRODUŽEN EKSPLATACIONI VIJEK DISTRIBUTIVNE MREŽE,
STVORENI USLOVI ZA KVALITETNO SNABDIJEVANJE U VRIJEME LOŠIJIH HIDROLOŠKIH PERIODA.
EFEKTI UVOĐENJA SISTEMA KONTROLE I
AUTOMATSKE REGULACIJE PRITISKA : UŠTEDA
ZAMJENI U OPISU !!!
UPOREDNI DIJAGRAM DNEVNIH ISPORUKA JANUAR 2005-JANUAR 2006
0
500
1.000
1.500
2.000
2.500
3.000
3.500
4.000
4.500
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Vrijeme
Dn
ev
na
is
po
ruk
a (
m3
)
Dnevna isporuka Jan 2005-prije uvođenja regulacije
Dnevna isporuka Jan 2006-nakon uvođenja regulacije
JP „VODOVOD I KANALIZACIJA” GRAČANICA
NASTAVAK AKTIVNOSTI NA SMANJENJU GUBITAKA
U VODOVODNOM SISTEMU U PERIODU
2006-2014 GODINA
SPIRALA SIGURNE I USPJEŠNE BUDUĆNOSTI
VODOVODNOG SISTEMA
JP „VODOVOD I KANALIZACIJA” GRAČANICA
NA OSNOVU IZVRŠENIH MJERENJA I PROVEDENIH POTREBNIH
ANALIZA PRIPREMLJEN JE DOKUMENT „ANALIZA GUBITAKA U VDS
GRAČANICA” I ZATIM PLANSKI NASTAVLJENE AKTIVNOSTI NA
SISTEMSKOM RJEŠAVANJU GUBITAKA
DEFINISANI SU SLJEDEĆI KORACI DJELOVANJA:
KORAK A: -UTVRĐENO STANJE GUBITAKA (PRIMJENA
NAJBOLJIH SVJETSKIH ISKUSTAVA)
-IZRAĐENA BILANSA VODE
KORAK B: -USTANOVLJENO JE „GDJE SE NALAZIMO”
(PRIMIJENJENI SU USPOREDIVI INDIKATORI)
KORAK C: -ANALIZIRANI SU PODACI I KREIRANA JE STRATEGIJA
-UTVRĐENI SU GENERALNI CILJEVI (2-3% GODIŠNJE
SMANJENJE GUBITAKA I SMANJENJE ILI INDIKATORA)
JP „VODOVOD I KANALIZACIJA” GRAČANICA
KORAK D: -IMPLEMENTACIJA PROGRAMA
NASTAVAK ZONIRANJA DISTRIBUTIVNE MREŽE
(USPOSTAVLJENE 3 NOVE DMA ZONE U GRADSKOM SISTEMU),
PROŠIRENJE SISTEMA DALJINSKOG NADZORA (FORMIRANE 4
NOVE STANICE DALJINSKOG NADZORA),
UNAPREĐENJE SISTEMA REGULACIJE PRITISKA – 2008 -2010
(UVEDENA DVA DODATNA STEPENA FIKSNE REGULACIJE U
ZONI GRAD I DVIJE FIKSNE REGULACIJE U SISTEMU PRIBAVA),
USAVRŠEN SISTEM REGULACIJE PRITISKA – 2013 GODINA
U ZONI GRAD INSTALIRAN UREĐAJ „REGULO” I SADA
REGULACIJOM PRITISKA „ONLINE” UPRAVLJA NAJVIŠI
POTROŠAČ U SISTEMU,
IZVRŠENA NABAVKA OPREME
(KORELATOR, GEOFON, UZ MJERAČ PROTOKA,
DETEKTOR CIJEVI, DIGITALNI MJERAČ PRITISKA, ITD),
JP „VODOVOD I KANALIZACIJA” GRAČANICA
REDOVNA AKTIVNOST NA DETEKCIJI CURENJA SA BRZIM
DJELOVANJEM NA SANACIJI,
UVEDEN RADISKI SISTEM OČITANJA VODOMJERA
PRIVREDNIH SUBJEKATA U INDUST. ZONI DONJI GRAD,
POKRENUT PROCES UVOĐENJA RADISKOG OČITANJA U
STANOVIMA KOLEKTIVNOG STANOVANJA
REALIZOVANA PRVA , DRUGA I TREĆA FAZA
UVEDEN I USAVRŠEN NADZORNO-UPRAVLJAČKI SISTEM U
DISPEČERSKOM CENTRU PUTEM SCADA SISTEMA.
PRENOS PODATAKA PUTEM GPRS-a,
OSAVREMENJEN SISTEM DEZINFEKCIJE VODE
ANALIZA REZIDUALNOG HLORA NA MJESTU
DEZINFEKCIJE I NA VIŠE MJESTA U MREŽI SA „ONLINE”
PODACIMA NA SCADA,
REKONSTRUKCIJA DIJELA DISTRIBUTIVNE MREŽE U
SISTEMU
PREGLED DMA ZONA, LOKACIJA NADZORA I MJESTA
MJERENJA U SISTEMU GRAČANICA
DMA ZONE U SISTEMU GRAČANICA
ZONA GORNJI GRAD
ZONA SREDNJI GRAD
ZONA DONJI GRAD
ZONA ČIRIŠ
ZONA MEJDANIĆ
ZONA DRAFNIĆI
ZONA RITOŠIĆI
ZONA PRIBAVA
UPOREDNI DIJAGRAM MJESEČNE ISPORUKE IZ REZERVOARA
U PERIODU 2004-2013 GODINA
NADZORNO-UPRAVLJAČKI CENTAR - SCADA
GENERALNI PREGLED GUBITAKA U PERIODU
2004-2014
Zemlje u
razvoju Razvijene zemlje
GRUPA Izračunati ILI
za ovaj sustav Opći opis kategorija kontrole stvarnih gubitaka za razvijene zemlje i zemlje u razvoju
ILI raspon ILI raspon
manje od 4 manje od 2 A 2,8
Daljnje smanjenje gubitaka možda će biti ekonomski neopravdano osim u slučaju
nestašice vode; potrebna je precizna analiza da bi se utvrdila financijski najisplativija
poboljšanja
4 do < 8 2 do < 4 B Potencijal za navedena poboljšanja; razmislite o kontroli tlaka, boljoj aktivnoj kontroli
curenja i boljem upravljanju i održavanju sustava
8 do < 16 4 do < 8 C
Slaba kontrola gubitaka; može se podnijeti jedino ako je voda jefitina i u izobilju; čak i u
tom slučaju, analizirajte stupanj i prirodu gubitaka i povećajte nastojanja u smanjenju
gubitaka
16 ili više 8 ili više D Jako neučinkovita upotreba resursa; programi smanjenja gubitaka su prijeko potrebni i
trebali bi biti prioritet
GRAFIČKI PRIKAZ ODNOSA OBRAČUNATE (FAKTURISANE) I
NEOBRAČUNATE KOLIČINE VODE U PERIODU 2004-2014
GODINA
FINANSIJSKI EFEKTI PRIMJENE SVIH MJERA NA OPTIMIZACIJI I
SMANJENJU GUBITAKA VODE KAO I UŠTEDA ELEKTRIČNE
ENERGIJE
FINANSIJSKE UŠTEDE PRIMJENOM SVIM MJERA NA
OPTIMIZACIJI I SMANJENJU NEOBRAČUNATE VODE:
PROSJEČNO 20% SMANJENJE UKUPNIH GODIŠNJIH TROŠKOVA U
PROIZVODNJI I ODRŽAVANJU VODOVODNOG SISTEMA
MJERE UNAPREĐENJA U NAREDNOM PERIODU
REDNI
BROJ
KATEGORIJE UNAPREĐENJA
AKTIVNOSTI I MJERE GENERALNI CILJEVI
1 PRIMJENA I W A
METODOLOGIJE U ANALIZI
GUBITAKA VODE
BILANSA VODE
BABE METODA
FAVAD METODA
UTVRĐIVANJE ICF INDIKATORA
KRATKOROČNO RAZDOBLJE
(2-3 GODINE):
ILI INDIKATOR=ispod 2,5
GUBICI U SISTEMU= ispod 30%
SREDNJOROČNO RAZDOBLJE
(CCA 5 GODINA):
ILI INDIKATOR=ispod 2
GUBICI U SISTEMU= ispod 27%
2 ZONIRANJE I SISTEM
DALJINSKOG NADZORA
3 NOVE LOKACIJE (UREĐAJA) ZA DALJINSKI
NADZOR (PROTOK, PRITISAK, NIVO)
3 BALANSIRANJE SISTEMA ANALIZA UNAPREĐENJA REGULACIJE PRITISKA
(I PRIMJENA ZRAČNIH VENTILA) U SISTEMU
IZRADA HIDRAULIČKO-MATEMATIČKOG
MODELA
4 OSAVREMENJAVANJE NABAVKA DODATNIH UREĐAJA
USTANOVLJAVANJE BAZE PODATAKA
IMPLEMENTACIJA PROGRAMSKIH RJEŠENJA,
PRAĆENJA I ANALIZE
PROGRAMSKA NADOGRADNJA KATASTRA
INSTALACIJA I PRIKLJUČAKA POTROŠAČA
5 ORGANIZACIJA I
ODGOVORNOSTI
UNAPREĐENJE SLUŽBE ZA GUBITKE
USPOSTAVLJANJE PROCEDURA I
ODGOVORNOSTI ZA IZVRŠENJE I KONTROLU
6 PREVENTIVNO ODRŽAVANJE PRIMJENA METODOLOGIJE PREVENTIVNOG
ODRŽAVANJA
7 PRIMJENA INDIKATORA PRIMJENA I W A INDIKATORA O STANJU
SISTEMA I UČINKOVITOSTI U KONTROLI
GUBITAKA
ZAKLJUČAK
DOLAZI VRIJEME „PAMETNIH“ VODOVODNIH
SISTEMA
NEUM, 09.07.2015.
HVALA NA PAŽNJI