Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Main FeaturesThe DTI can collect information from up to 10 of each of the following Autoflame products:
•Mk7MMController,MiniMk8MMController,MiniMk7MMController,oranycombinationtoatotal of 10 units
•AutoflameExhaustGasAnalyser,eitherusedinconjunctionwithanMMControllerfortrim,orlinkeddirectlytotheDTIformonitoringpurposesonly
•Upto10Input/Outputmoduleswithbothanalogue and digital connections
There are up to 150 items of information that are viewableviatheDTIfromeachMMController&EGA.
OverviewTheDTI(DataTransferInterface)letsusersknowinrealtimehowtheboilersareperforming,eitheron-sitethroughitsbuilt-intouchscreen,viaalocalPC,orviaaBMSsystem.Itstoresdatahistoryofallboilersfor2years.
TheDTIisagatewayforcommunicatingwiththeAutoflameMMController/EGArangeofproducts.The DTI can collect and store information from a maximumof10AutoflameSystemsinonelocation.TheinformationgatheredislateravailablefortransmissiontoanexternalsourcesuchasaBMSviaRS422orEthernetlinks.ThedatagatheredbytheAutoflameDTIcanbesynchronisedandviewedusingtheincludedCEMS(ContinuousEmissionsMonitoring)software,whichallowsdatacollectionoveralocalnetworkorovertheinternet.TheMk7DTIalsosupportstheModbusprotocoloverethernetandRS422asstandard.
TouchscreenMk7DTI
Monitor up to 10 Boilers RemotelyModbus/LAN/RemoteConnectivity•SaveDatafor2Years
BMS LocalPC
Upto10MMControllers
Upto10EGA’s
Upto10I/O’s
TypicalConfiguration
DTIMk7:DataTransferInterface
AutoflameEngineeringLtd.Autoflame.com
EGAInformation(Viewable&StoredwithintheDTIfor2Years)•O2,CO2,CO,NO,SO2&NO2percentile&ppmvalues
•Exhausttemperature,combustionefficiency,fuelconsumption&emissionsauditingdata
•EGAerrorconditions
•Flow-metering&on-lineExhaustGasAnalysisdata,bothinstantaneous&totalisedfor:O2,CO2,H2O,NO,CO,SO2,N2,totalemissionsasaweight,&correspondingvolumeatexhaustexittemperature&pressure
•Heatinput,heatloss&netusefulheat
•Netefficiency,grossefficiency&temperaturechange
•Fuelflowperhour&fuelflowtotalised
•Calculatedcostoffuelused(costpertonne)
DTI Input ValuesThefollowingsettingsmaybemodifiedinindividualMMControllersviatheDTI:
•Altersetpoint(individual&global)
•Enable/disableburner
•Re-orderboilersequencing&selectleadboiler
•Input/Outputlabelling&control
•Remoteloadindexcontrol
ConnectivityTheAutoflamenetworkoperatesusingatwo-corescreenedcable.TheDTIassesseseachitemonthenetworkperiodically,storingup-to-dateinformationontheDTI&outputstodefinedModbusaddresses.Thesearethenavailabletothirdpartysystems.TheDTIfeaturesdedicateddataportsforRS422&Ethernetconnections.The10.4”touch-screendisplaystheoperationalstatusoftheDTI’scommunications,withcorrespondingerrorconditionsintheeventofacommunicationfailure.
AutoflameCEMSAuditSoftwareManager/Supervisor•Customizablesitelayouts,boilerimages,sitenaming, ancillaries,mechanical&electricaldrawings
•AbilitytoviewlivestreameddatathroughaMk7MMControllerscreen&EGAscreen
•Remoteorlocalcontrol
•RemoteconnectiontoDTIoverinternetorLAN
Thedataissampledat1minuteintervals&storedonanSDCardwithintheMk7DTIandwithintheEGA.
Avarietyofconfigurationsareavailable,includingtheabilitytomonitormultipleDTI’sfromasinglePC(requiresadditionalproducts).ContactAutoflameoryourlocaltechnologycentreformoreinformation.
MMControllerData(Viewable&Stored within the DTI for Two Years):•Requiredandactualboilertemperatureorpressure
•Burnerfiringrate(%)
•Fuelselected&flowmeteringvalues
•Auto/Hand/Lowflameholdoperation
•Numberofcontrolchannelsoptionedshowingbothactual&commissionedpositions
•Maximum/minimumsetpointacceptedfromDTI
•Sequencestatus(on,stand-by,warm,off)&leadboilerstatus
•Enable/disabledstatus&errorconditions
•Alarmstatus
•Firstoutannunciation*
•Draftcontrol*
FlameSafeguardFunctions•Burnerfiringstatus(off,firing,purge,ignition,offline)
•Hoursrun&numberofstart-ups
•Lockoutstatus
•Gaspressure(online&commissioned)
•Oilpressure(online&commissioned)
•Airpressure(online&commissioned)
WaterLevelControlFunctions•Operationalinformation:steamandfeedwater*
•Temperature,pumpstatusandvalveposition*
•Probeinformation:temperature,signalvalue*
•Steamflowmeteringdata*
*RequiresMk7MMControllerwithExpansionBoard
DTIMk7:DataTransferInterface