25
LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

Embed Size (px)

DESCRIPTION

2002 UW SPONSORED STUDY STUDY POSSIBILITY FOR INCREASED SIMULTANEOUS NITRIFICATION AND DENITRIFICATION INCREASED TANK LOADINGS TO ACCOMPLISH GOAL PROVIDED THE OPPORTUNITY TO EVALUATE PLANT CAPACITY

Citation preview

Page 1: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

LOW D.O. OPERATION:EFFECTS ON BIOLOGICAL PHOSPHORUS

REMOVAL, OXYGEN TRANSFER EFFICIENCY,DENITRIFICATION, AND ENERGY SAVINGS

Page 2: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

• IN 1980 THE PLANT WAS DESIGNED FOR 50 MGD NITRIFICATION

• IN 1996 THE PLANT WAS MODIFIED FOR BIO-P

• ABOUT 20% OF THE TANKAGE WAS REMOVED FROM AERATION

• IT WAS STILL ESTIMATED THE PLANT CAPACITY WAS 50 MGD

• TOO GOOD TO BE TRUE???

Page 3: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

2002 UW SPONSORED STUDY

• STUDY POSSIBILITY FOR INCREASED SIMULTANEOUS NITRIFICATION AND DENITRIFICATION

• INCREASED TANK LOADINGS TO ACCOMPLISH GOAL

• PROVIDED THE OPPORTUNITY TO EVALUATE PLANT CAPACITY

Page 4: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

NITRIFICATION/DENIT UW STUDY IN ‘83 & ‘84

•LOW D.O. WAS MAINTAINED IN AERATION TANKS (<0.5 MG/L)•DENITRIFICATION WAS THE GOAL•FILAMENTOUS GROWTH (TYPE 021N) AND NOCARDIA INTERRUPTED STUDY•FILAMENTOUS CONTROL WAS A CONSTANT BATTLE UNTIL BIO-P

Page 5: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

-The plant is a Modifed UCT process without mixed liquor recycle-Prior to study the D.O. setpoint for pass 2 was set at 1.5 mg/l and air flow controlled in passes 1 & 2 to meet it. The study setpoint was set at 0.3 mg/l-The D.O. setpoint in pass 3 controlled air flow to pass 3 and was normally set at 2.5 mg/l. The study setpoint was 1.0 mg/l.

Page 6: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

In August, ‘01 one half of plant 4 was removed from service in order to increase the organic loading and enable operating at lower D.O.’s Plant 3 was the control plant with the same volume of tankage in serviceduring both time periods.

Page 7: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

The goal was to maintain the same sludge age in both plants for both time periods.The higher organic loadings in plant 4 allowed operating at lower D.O.’s. The effluent TN was about 3 mg/l lower in plant 4 than plant 3 and the TP levels aboutthe same. The air usage/lb of BOD removed was 40% less in plant 4 than plant 3.

Page 8: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

Operating D.O. Levels & Oxygen Transfer Efficiency

Page 9: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

The District owns an off-gas apparatus for testing oxygen transfer efficiency. Thistool has been used for several research projects with the UW on fine bubble diffusion.The purpose for these investigations was to check if alpha was suppressed in the tankage as a result of maintaining lower D.O.’s.

Page 10: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

The points 1-1 thru 3-6 are points where the off-gas testing was carried out,in both plants 3 & 4, before and during the test period.

Page 11: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

-D.O. measurements are continuously recorded and compressed to hourly averages.-Prior to the test period the D.O. setpoint at the first point could be maintainedto + or - 0.5 mg/l about 70% of the time, but because of the low organic loadingsthe D.O.’s were always much higher at the tail end of the tank than the setpoint. -This was because minimum air flow setpoints controlled.

Page 12: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

During the test period the D.O. at the first probe in the tank could be maintained veryclose to the setpoint of 0.3 mg/l and at the tail end of the tank was within 0.2 mg/l ofthe 1.0 mg/l setpoint 75% of the time. The other 25% of the time were low loadingperiods and minimum air flow setpoints still controlled.

Page 13: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

The profile of alpha in the plant 4 tanks was approximately the same with normal,low loadings and high D.O.’s as during the test with higher loadings and low D.O.’s

Page 14: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

The D.O. profiles were much different with the two conditions

D.O.'s During 2002 Off-Gas Testing

0

1

2

3

4

5

6

7

8

1-1 1-2 2-1 2-2 2-3 2-4 2-5 2-6 3-1 3-2 3-3 3-4 3-5 3-6

D.O

. (m

g/l)

D.O. Plt4 7/14 (Normal Ops)

D.O. Plt4 8/28 (Test)

Page 15: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

-The field transfer efficiencies were much different because of the D.O. profiles. -If the demand can be satisfied in passes 2 & 3 and take advantage of low D.O.’s and high alpha values, significant air can be saved.

Page 16: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

BOD Loadings have increased 62% from Jan, ‘88 to Jan, ‘06

Avg Monthly BOD Loadingsy = 138.68x - 93473

R2 = 0.8803

0

20000

40000

60000

80000

100000

120000

Jan-

85

Jan-

86Ja

n-87

Jan-

88Ja

n-89

Jan-

90Ja

n-91

Jan-

92Ja

n-93

Jan-

94Ja

n-95

Jan-

96Ja

n-97

Jan-

98

Jan-

99Ja

n-00

Jan-

01Ja

n-02

Jan-

03Ja

n-04

Jan-

05Ja

n-06

Jan-

07Ja

n-08

Jan-

09Ja

n-10

Jan-

11Ja

n-12

Jan-

13Ja

n-14

Jan-

15Ja

n-16

Jan-

17

Jan-

18Ja

n-19

Jan-

20

BOD

Loa

ding

(lbs

/day

)

Page 17: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

TKN Loadings have increased 56% from Jan, ‘88 to Jan, ‘06

Average Monthly TKN Loadings

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

Jan-

85

Jan-

86

Jan-

87

Jan-

88

Jan-

89

Jan-

90

Jan-

91

Jan-

92

Jan-

93

Jan-

94

Jan-

95

Jan-

96

Jan-

97

Jan-

98

Jan-

99

Jan-

00

Jan-

01

Jan-

02

Jan-

03

Jan-

04

Jan-

05

Jan-

06

Jan-

07

Jan-

08

Jan-

09

Jan-

10

Jan-

11

Jan-

12

Jan-

13

Jan-

14

Jan-

15

Jan-

16

Jan-

17

Jan-

18

Jan-

19

Jan-

20

TKN

(lbs

/day

)

Page 18: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

Air use has increased 45% from Jan, ‘88 to Jan, ‘06, much less than 60%’02 The drop in air use was due to changing control strategy following this study--a savings of about $32,000 in ‘03 ‘85-’88 Reduced air use was due to replacement of coarse bubble diffusers with fine bubble and implementation of D.O. control

Air Flow vs. Time

0.00

10.00

20.00

30.00

40.00

50.00

60.00

Oct

-85

Oct

-86

Oct

-87

Oct

-88

Oct

-89

Oct

-90

Oct

-91

Oct

-92

Oct

-93

Oct

-94

Oct

-95

Oct

-96

Oct

-97

Oct

-98

Oct

-99

Oct

-00

Oct

-01

Oct

-02

Oct

-03

Oct

-04

Oct

-05

Air F

low

(m

il C

F/D)

Page 19: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

-Air flow is maintained constant at locations 1-1 & 1-2 regardles of D.O.’s. at about 1.3 cfm/diffuser -The D.O. setpoint for the second probe is 0.5 and controls air to pass #2 -The D.O. setpoint for the final probe is 3.0 mg/l, controls air in the last pass, and is set as such to assure an effluent D.O. of 5.0 mg/l

Page 20: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

A real time process calculator/simulator in the plant process control system was used to project plant capacity with the knowledge gained as a result of the study.

Page 21: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

The aeration capacity of the plant likely won’t be reached until the averageAnnual daily flow exceeds 60 MGD.

Page 22: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

Plant clarifier capacity may be reached sooner, when the average annualdaily flow exceeds 50 MGD.

Page 23: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

Operational Observations

• Diffusers have shown no more of a tendency to plug since Bio-P

• Occassionally there has been minor foaming organism growth on the tanks

• A related process, UV disinfection, has benefited from Bio-P; quartz tube are acid cleaned once/year versus every 3-4 weeks prior to Bio-P

Page 24: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

SUMMARY

• Plant was capable of N & P removal at higher loadings and much lower D.O. concentrations

• Settling remained good• Oxygen Transfer efficiency remained high at lower operating D.O. level• It appears optimistic projections for future

plant treatment capacity look good

Page 25: LOW D.O. OPERATION: EFFECTS ON BIOLOGICAL PHOSPHORUS REMOVAL, OXYGEN TRANSFER EFFICIENCY, DENITRIFICATION, AND ENERGY SAVINGS

A paper prepared and presented at Central States on this project can be found at www.cswea.org, click on

Published Papers,“Effect of Biological Phosphorus Removal On Plant Operations and

Capacity at the Nine Springs WWTP