Installation Manual - Jetmaster .1 Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU,

  • View
    216

  • Download
    0

Embed Size (px)

Text of Installation Manual - Jetmaster .1 Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU,...

  • 1Heat & Glo MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual 2304-970 Rev. F 4/15

    Models:

    Installation ManualInstallation and Appliance Setup

    INSTALLER: Leave this manual with party responsible for use and operation.OwNER: Retain this manual for future reference.

    NOTICE: DO NOT discard this manual!

    DO NOTstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthisoranyotherappliance.

    Whattodoifyousmellgas - DO NOTtrytolightanyappliance.- DO NOTtouchanyelectricalswitch.DO

    NOTuseanyphoneinyourbuilding.- Leavethebuildingimmediately.- Immediately call your gas supplier fromaneighborsphone.Followthegassup-pliersinstructions.

    - Ifyoucannotreachyourgassupplier,callthefiredepartment.

    Installationandservicemustbeperformedbyaqualifiedinstaller,serviceagency,orthegassupplier.

    wARNING: FIRE OR EXPLOSION HAZARDFailuretofollowsafetywarningsexactlycould result in serious injury, death, or propertydamage.

    DANGERHOT GLASS WILLCAUSEBURNS.

    DO NOT TOUCH GLASSUNTILCOOLED.

    NEVER ALLOWCHILDRENTOTOUCHGLASS.

    A barrier designed to reduce the risk ofburnsfromthehotviewingglassisprovidedwiththisapplianceandshallbeinstalledforthe protection of children and other at-riskindividuals.

    MEZZO-1000-AUMEZZO-1300-AUMEZZO-1300ST-AUMEZZO-1600-AU

    NOTE: NOT INTENDED FOR FIREPLACE INSERT.

    Ref No: GMK10222AS4553:

    DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE wHILE IT IS IN OPERATION. DO NOT MODIFY THIS APPLIANCE.

  • 2Heat & Glo MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual 2304-970 Rev. F 4/15

    Safety Alert Key: DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE: Used to address practices not related to personal injury.

    Table of Contents

    InstallationStandardWorkChecklist. . . . . . . . . . . . . . . . . . . . 3

    1ProductSpecificandImportantSafetyInformation A. ApplianceCertification. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4B. GlassSpecifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4C.GasPressureRequirements. . . . . . . . . . . . . . . . . . . . . . . 4D.HighAltitudeInstallations. . . . . . . . . . . . . . . . . . . . . . . . . . 5E. Non-CombustibleMaterialsSpecification..............5F. CombustibleMaterialsSpecification . . . . . . . . . . . . . . . . . 5G.ElectricalCodes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

    2GettingStartedA. DesignandInstallationConsiderations. . . . . . . . . . . . . . . 6B. ToolsandSuppliesNeeded. . . . . . . . . . . . . . . . . . . . . . . . 6C. InspectApplianceandComponents. . . . . . . . . . . . . . . . . . 6

    3FramingandClearances A. Appliance/DecorativeFrontDimensionDiagrams. . . . . . . 7B. ClearancestoCombustibles . . . . . . . . . . . . . . . . . . . . . . 11C.ConstructingtheApplianceChase. . . . . . . . . . . . . . . . . . 12D. FloorProtection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    4 Termination Location and Vent Information A. VentTerminationMinimumClearances. . . . . . . . . . . . . . 16B. ChimneyDiagram...............................17C. ApprovedPipe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18D.UseofElbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18E. MeasuringStandards. . . . . . . . . . . . . . . . . . . . . . . . . . . . 18F. ExhaustRestrictorInstructions.....................18G.VentDiagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    5VentClearancesandFraming A. PipeClearancestoCombustibles . . . . . . . . . . . . . . . . . . 26B. WallPenetrationFraming/Firestops. . . . . . . . . . . . . . . . . 26C. InstalltheCeilingFirestop. . . . . . . . . . . . . . . . . . . . . . . . 27D. InstallAtticInsulationShield. . . . . . . . . . . . . . . . . . . . . . . 27E. InstallingtheHeat-ZoneKit . . . . . . . . . . . . . . . . . . . . . . 28

    6 Appliance Preparation

    A. VentCollarPreparation. . . . . . . . . . . . . . . . . . . . . . . . . . 29B. SecuringandLevelingtheAppliance. . . . . . . . . . . . . . . . 30

    7VentingandChimneys A. AssembleVentSections. . . . . . . . . . . . . . . . . . . . . . . . . 31B. AssembleSlipSections. . . . . . . . . . . . . . . . . . . . . . . . . . 32C. SecureTheVentSections. . . . . . . . . . . . . . . . . . . . . . . . 32D.DisassembleVentSections. . . . . . . . . . . . . . . . . . . . . . . 33E. VerticalTerminationRequirements. . . . . . . . . . . . . . . . . . 34F. HorizontalTerminationRequirements . . . . . . . . . . . . . . . 35

    8 Electrical Information A. GeneralInformation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37B. WiringRequirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    9 Gas Information A. FuelConversion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39B. GasPressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39C.GasServiceAccess. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39D.GasConnection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41E. HighAltitudeInstallations. . . . . . . . . . . . . . . . . . . . . . . . . 41F. AirShutterSetting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

    10FinishingA.FacingandFinishingInstructions...................43B. MantelandWallProjections. . . . . . . . . . . . . . . . . . . . . . . 48C.DecorativeFrontDimensionsforFinishing . . . . . . . . . . . 49

    11 Appliance Setup A. FixedGlassAssembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 50B.RemovetheShippingMaterials. . . . . . . . . . . . . . . . . . . . 50C.CleantheAppliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50D.InstallGlassRefractoryPanels. . . . . . . . . . . . . . . . . . . . 50E. InstallMedia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51F.InstallLogSet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53G.ApplianceOperation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

    12 Reference Materials A. VentComponentsDiagrams . . . . . . . . . . . . . . . . . . . . . . 54B. Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

    =Containsupdatedinformation.

  • 3Heat & Glo MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual 2304-970 Rev. F 4/15

    Installation Standard work Checklist

    Customer: Lot/Address:

    Model (circle one): MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1600-AU, MEZZO-1300ST-AU

    Date Installed: Location of Fireplace:Installer:Dealer/Distributor Phone # Serial #:

    Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed ______________________________________________________________________________________________________________________________________________________________________________________Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)

    Appliance Install Sections 3 and 6 YES IF NO, WHY?Veri ed that the chase is insulated and sealed. (Pg. 12) ___________________________Required factory-installed non-combustible board is in place. ___________________________Veri ed clearances to combustibles. (Pg. 11,13,14) ___________________________Fireplace is leveled and secured. (Pg. 30) ___________________________Pipe heat shield is attached to header. Header no wider than 3.5 in.(2x4) (Pg. 29) ___________________________

    Venting/Chimney Sections 4,5 and 7Venting con guration complies to vent diagrams. (Pg. 18-25) ___________________________Venting installed, locked, and secured in place with proper clearance. ___________________________Firestops installed. (Section 5) ___________________________Attic insulation shield installed. (Pg. 27) ___________________________Exterior wall/Roof ashing installed and sealed. (Section 7) ___________________________Terminations installed and sealed. (Section 7) ___________________________

    Electrical Section 8 (Pg 37-38)Unswitched power (220/240 VAC) provided to the appliance. ___________________________Switch wires properly installed. ___________________________

    Gas Section 9 (Pg 39-42)Proper appliance for fuel type. ___________________________Was a conversion performed? ___________________________Leak check performed and inlet pressure veri ed. ___________________________Veri ed proper air shutter setting for installation type. ___________________________

    Finishing Section 10 (Pg 43-49)Combustible materials not installed in non-combustible areas. ___________________________Veri ed all clearances meet installation manual requirements. ___________________________Finishing done correctly using inside t or overlap t method. ___________________________ Finishing template removed. ___________________________Mantels and wall projections com