Sandhurst Geotech Pty Ltd, Trading as Geotechnical Testing Services – Southern. ABN: 18 169 924 109 ACN: 169 924 109
Email: [email protected]; Ph: 03 5441 4881; Fax: 03 5441 5089; Mail Address: PO Box 13, STRATHDALE, Vic, 3550
Offices: La Trobe University Applied Science 2 Building 7 Sharon Street, Flora Hill, VIC 3550; Shed 3, 140 Ogilvie Avenue, Echuca , VIC 3654,
Geotechnical Investigations Contract Drilling Land Capability Assessments Contamination Assessments Compaction Control Testing On-site Wastewater Management Site Classifications Residential and Industrial Soil, Concrete and Aggregate Testing Laboratories Site Laboratory
Construction Material Testing Services www.geotestsouthern.com.au
Proposed Sewer Alignment
Dukes Lane, Strathfieldsaye
Geotechnical investigation for Tomkinson
Report 20C 1181 October 2020
Dukes Lane, Strathfieldsaye
Geotechnical Investigation for
Tomkinson
Revision
Revision Authorised Date
20C 1181 SEH 26/10/20
Distribution (this version only)
Recipient Format Date
GTS On file 26/10/20
Tomkinson Attn: Matt Elliot
Email PDF [email protected]
26/10/20
Geotechnical Testing Services – Southern Report: 20C 1181 Report
TABLE OF CONTENTS
1 INTRODUCTION ......................................................................................................... 1
2 SITE AND GEOLOGY ................................................................................................. 1
2.1 SITE LOCATION AND GENERAL CONDITIONS ................................................ 1
2.2 GEOLOGY ............................................................................................................ 1
3 FIELDWORK ............................................................................................................... 1
4 DISCUSSION ............................................................................................................... 3
5 IMPORTANT NOTES ABOUT THIS REPORT ............................................................ 4
6 DISCLAIMER ............................................................................................................... 4
APPENDIX
Site Plan Engineering Logs Descriptive Terms
Geotechnical Testing Services – Southern Page 1 Report: 20C 1181 Report
1 INTRODUCTION
Tomkinson commissioned Geotechnical Testing Services (GTS) to undertake a geotechnical
investigation for the proposed sewer pipeline at Dukes Lane, Strathfieldsaye.
The purpose of the investigation was to assess general subsurface conditions at the site with a view
to providing comments and design parameters for the proposed construction.
2 SITE AND GEOLOGY
2.1 SITE LOCATION AND GENERAL CONDITIONS
The site is located on the western side of Dukes Lane, Strathfieldsaye.
The site has a slight fall to the west and is currently vacant. Sheepwash Creek forms the western
boundary of the site. At the time of the investigation, the surface of the site was moist with a good
coverage of seeded and natural grasses. There were many small to large sized trees surround the
road and creek reserve bordering the investigation site. There was no visual evidence of surface
cracking or exposed surface rock.
2.2 GEOLOGY
The Victorian Government’s online “Geovic” map shows the site to be underlain by Quaternary aged
alluvial deposits, with Ordovician aged sedimentary deposits of the Castlemaine group towards the
sites south-eastern boundary. This was generally confirmed by the field data.
3 FIELDWORK
The geotechnical investigation was conducted on the 8 of October 2020 and involved the drilling of
3 boreholes by a Gemco drilling rig to depths of 4.5 to 9.3 metres. Pocket Penetrometer (PP) tests
were conducted in the boreholes with the results included on the engineering logs.
It is noted that a 4th borehole was proposed, however that area was too wet for access.
The field investigation was conducted by a technician under the direction of a Geotechnical
Engineer, who logged the subsurface profile and determined the testing program. The engineering
logs are included in the Appendix with their locations as designated by the client shown on the
enclosed site plan.
Geotechnical Testing Services (Southern) Report: 20C 1181 Report
Page 2
The field investigation indicated that the soil profile is variable across the site, but typical of an alluvial
profile and may be summarized as follows:
Borehole 1
(Gravelly) Silty CLAY, medium plasticity, brown, pale brown, black, dark grey, stiff to very stiff
to a depth of 3.2 metres
Overlying
(Gravelly) Silty CLAY, dark grey, mottled brown, orange brown, soft
To termination at 4.5 metres
Borehole 2
FILL: Clayey Sandy SILT, fine to medium, brown, low plasticity, medium dense
To a depth of 0.2 metres
Overlying
Silty CLAY, medium plasticity, brown, mottled brown, pale brown, stiff,
to a depth of 1.1 metres
Overlying
Clayey SAND & Clayey Sandy GRAVEL, fine to coarse, brown, orange/brown, medium dense
to a depth of 3.2 metres
Overlying
Silty CLAY, low plasticity, pale grey, stiff,
to a depth of 4.2 metres
Overlying
SILTSTONE, extremely weathered, pale grey, low to moderate strength
To refusal depth of 9.3 metres
Borehole 2
FILL: Clayey Sandy SILT, fine to medium, brown, low plasticity, medium dense
To a depth of 0.1 metres
Overlying
Clayey/Gravelly SAND, fine to medium, orange/brown, medium dense to dense
to a depth of 2.5 metres
Overlying
SILTSTONE, extremely weathered, off white, low strength
To termination depth of 3.0 metres
Geotechnical Testing Services (Southern) Report: 20C 1181 Report
Page 3
Reference should be made to the appended engineering logs for a full description of subsurface
conditions at each location.
The ground water level was monitored in each borehole after being left open for a short period of
time and has been summarised in the following table:
Borehole (BH) Depth below (m)
1 3.3
2 2.8
3 Dry
It is noted that the ground water level may vary from the above due to seasonal and climatic
changes.
4 DISCUSSION
It is understood that the pipeline is to consist of a sewer and most likely to be open trenching with
potential for under boring.
Based on the results of this investigation, the material to be encountered will vary from Silty Clay to
Gravelly/Clayey Sand, Clayey Sandy Gravel and weathered Siltstone rock. Field assessment and
insitu strength tests indicate that there is an allowable bearing pressure of 100kPa available for the
proposed pipeline.
It is expected that excavation/boring will generally be achieved with conventional earthmoving
equipment (large excavators). However, it is noted that weathered Siltstone rock was encountered
at depths of 2.5 (BH3) and 4.2m (BH2). Past experience with our drill rig indicates that it can drill
through extremely weathered rock but refuses on moderate strength rock or better. It is noted that
refusal was encountered in BH2 at a depth of 9.3m which is short of the targeted depth of 11m. In
addition, it is noted that with weathered Ordovician rock (Siltstone/Sandstone), it can vary over short
distances and harder Sandstone seams maybe encountered in areas not directly investigated. As
such, the use of a ripper or pneumatic hammer may be required. If rock is encountered while under
boring, the use of rock coring bits may be required for the horizontal bores.
In regards to the stability of the excavations, with the variability between clay and sand along the
alignment, and the presence of groundwater at depths of 2.8 and 3.3 metres in 2 of the boreholes,
pending invert levels, instability of the excavations may be encountered particularly in cohesionless
sands and gravels. As such, shoring of trenches or casing of underbores is likely to be required.
Geotechnical Testing Services (Southern) Report: 20C 1181 Report
Page 4
For excavations above the water table and in the weathered rock, it is expected that they will remain
stable in the near vertical in the short term (1 week). For longer term opening it may be necessary
to batter the walls back to 1:2 (H:V) with the top soil material being at 1:1 or even benched out. The
stability of the weathered rock can be dependent on the jointing/bedding of the rock should be
inspected by a Geotechnical Engineer during excavation.
It is recommended that plant equipment (i.e. trucks, excavators etc) and excavated material remain
at minimum of 1.5 metres away from the trench opening to ensure that no additional loading is
influencing the excavated trench walls which may increase the risk of trench instability or failure.
5 IMPORTANT NOTES ABOUT THIS REPORT
The results from this investigation relate to the specified sites labelled throughout this document,
and hence the information obtained may need to be extrapolated to the rest of the designated area.
While care has been taken throughout this investigation, soil conditions can vary between each
individual test site and at depths greater than that drilled during this investigation. Hence, if variations
from this report are found during excavations/construction then Geotechnical Testing Services
should be notified so it can be assessed and appropriate advice provided.
The soil colours provided in the bore logs attached may vary with soil moisture content and individual
interpretation, therefore colour alone should not be used to identify these soils.
Strength characteristics of soils often exhibit a large variation between wet and dry conditions. Soil
characteristics of a soil profile are given on the soil conditions at the time of the investigation.
6 DISCLAIMER
This investigation has been carried out in goodwill and under the instructions of Tomkinson. The
investigation has been undertaken with the care and skill of competent personnel as defined within
Geotechnical Testing Services quality system. It is not a comprehensive investigation but a guide to
the conditions throughout the designated area.
This document has been prepared for Tomkinson, and hence no responsibility or liability is being
accepted to any third party, where any part of the report is used in either isolation or without
consideration of the whole document. This document is not appropriate where there has been a
significant change in the project or either for the specific needs of the reader.
Geotechnical Testing Services (Southern) Report: 20C 1181 Report
Page 5
Please, don’t hesitate to contact the undersigned, if you require any further information or
assistance.
Shane Hampton (BE (Hons)) MIEAust Principal Geotechnical Engineer Telephone: (03) 5441 4881 Mobile: 0437 496 215 Email: [email protected]
Geotechnical Testing Services (Southern) Report: 20C 1181 Report
Page 6
APPENDIX
BH3
BH2
BH1
D
U
K
E
S
L
A
N
E
LA
N
E
DU
KE
S
GTS REF: 20C 1181
DATE: 08 OCT. 2020
GEOTECHNICAL INVESTIGATION
APPROXIMATE LOCATIONS
NOT TO SCALE
CLIENT: TOMKINSON
LOCATION: DUKES LANE,
STRATHFIELDSAYE
PROPOSED SEWER ALIGNMENT
Borehole no.
Sheet no.
PO Box 13, Strathdale 3550 Job no.
Ph (03) 54414881 Fax (03) 5441 5089
Client : Date:
Project : Logged by:
Location : Dukes Lane, Strathfieldsaye
Drill model : Gemco HS7 Slope 90 deg RL surface: Not measured
Hole diameter : 100mm Bearing - deg Datum : -
Gravelly Silty CLAY (CI), medium M Stplasticity, brown, pale brown, black, some fine sand
0.50
1.00 PP 1.0m = 250 kPa
1.50 PP 1.5m = 250 kPa
2.00
2300mmSilty CLAY (CI), medium plasticity, M VStdark grey mottled brown 2.50
3.00 PP 3.0m = 340 kPa
3200mmSilty CLAY (CI), medium plasticity, M S SWL 3.3mdark grey mottled brown PP 3.5m = 90 kPa
4.00Gravelly Silty CLAY (CI), medium M Splasticity, dark grey mottled brown, orange/brown
BH1 terminated at 4.5 metres 4.50
Gra
phic
log
Wat
er
Moi
stur
e co
nditi
on
Con
sist
ency
den
sity
, in
dex Structure, additional
observations
Met
hod
Sup
portNotes
Samples Tests
ENGINEERINGBOREHOLE LOG
1
1 of 1
20C 1181
Tomkinson 8/10/2020
Proposed Sewer Alignment RC & MM
Material DescriptionDepth
(m)
Borehole no.
Sheet no.
PO Box 13, Strathdale 3550 Job no.
Ph (03) 54414881 Fax (03) 5441 5089
Client : Date:
Project : Logged by:
Location : Dukes Lane, Strathfieldsaye
Drill model : Gemco HS7 Slope 90 deg RL surface: Not measured
Hole diameter : 100mm Bearing - deg Datum : -
FILL: Clayey Sandy SILT (ML), M MD FILLbrown, low plasticity 200mmSilty CLAY (CI), medium plasticity, M Stbrown mottled pale brown, some fine sand 0.50
1.00 PP 1.0m = 210 kPa1100mm
Clayey SAND (SP), fine, orange/brown, M MDlow plasticity
1.50
1800mmClayey Sandy GRAVEL (GW), fine M MDto coarse, brown, orange/brown, 2.00low plasticity, fine sand
2.50
SWL 2.8m
3.00
3200mmSilty CLAY (CL), low plasticity, M Stpale grey
3.50
4.00 PP 4.0m = 210 kPa
Proposed Sewer Alignment RC & MM
Material DescriptionDepth
(m)
Gra
phic
log
Wat
er
Moi
stur
e co
nditi
on
Con
sist
ency
den
sity
, in
dex Structure, additional
observations
ENGINEERINGBOREHOLE LOG
2
1 of 3
20C 1181
Tomkinson 8/10/2020
Notes Samples
Tests Met
hod
Sup
port
Borehole no.
Sheet no.
PO Box 13, Strathdale 3550 Job no.
Ph (03) 54414881 Fax (03) 5441 5089
Client : Date:
Project : Logged by:
Location : Dukes Lane, Strathfieldsaye
Drill model : Gemco HS7 Slope 90 deg RL surface: Not measured
Hole diameter : 100mm Bearing - deg Datum : -
Silty CLAY (CL), low plasticity, M Stpale grey 4200mmSILTSTONE (XW), extremely M-D L - M Rock: low to mediumweathered, pale grey strength
4.50
5.00
5.50
6.00
6.50
7.00
7.50
8.00
2 of 3
20C 1181
Tomkinson 8/10/2020
Proposed Sewer Alignment RC & MM
ENGINEERINGBOREHOLE LOG
2
Con
sist
ency
den
sity
, in
dex Structure, additional
observations
Notes Samples
Tests Met
hod
Sup
port
Material DescriptionDepth
(m)
Gra
phic
log
Wat
er
Moi
stur
e co
nditi
on
Borehole no.
Sheet no.
PO Box 13, Strathdale 3550 Job no.
Ph (03) 54414881 Fax (03) 5441 5089
Client : Date:
Project : Logged by:
Location : Dukes Lane, Strathfieldsaye
Drill model : Gemco HS7 Slope 90 deg RL surface: Not measured
Hole diameter : 100mm Bearing - deg Datum : -
SILTSTONE (XW), extremely M-D L - M Rock: low to mediumweathered, pale grey strength
8.50
9.00
BH2 terminated at 9.3 metres By Refusal9.50
10.00
10.50
11.00
11.50
12.00
BOREHOLE LOG2
3 of 3
20C 1181
Tomkinson 8/10/2020
ENGINEERING
Proposed Sewer Alignment RC & MM
Material DescriptionDepth
(m)
Gra
phic
log
Wat
er
Moi
stur
e co
nditi
on
Con
sist
ency
den
sity
, in
dex Structure, additional
observations
Notes Samples
Tests Met
hod
Sup
port
Borehole no.
Sheet no.
PO Box 13, Strathdale 3550 Job no.
Ph (03) 54414881 Fax (03) 5441 5089
Client : Date:
Project : Logged by:
Location : Dukes Lane, Strathfieldsaye
Drill model : Gemco HS7 Slope 90 deg RL surface: Not measured
Hole diameter : 100mm Bearing - deg Datum : -
FILL: Clayey Sandy SILT (ML), 100mm M MD FILLbrown, low plasticityClayey SAND (SP), fine, orange/brown, M MDlow plasticity
0.50
1.00
1.50
1800mmGravelly SAND (SP), fine to M MD-medium, orange/brown, 2.00 Dfine to coarse gravel
2500mm 2.50SILTSTONE (XW), extremely D L Rock: Low strengthweathered, off white
3.00BH3 terminated at 3.0 metres
3.50
4.00
1 of 1
20C 1181
Tomkinson 8/10/2020
Proposed Sewer Alignment RC & MM
ENGINEERINGBOREHOLE LOG
3
Con
sist
ency
den
sity
, in
dex Structure, additional
observations
Notes Samples
Tests Met
hod
Sup
port
Material DescriptionDepth
(m)
Gra
phic
log
Wat
er
Moi
stur
e co
nditi
on
DESCRIPTIVE TERMS BOREHOLE/EXCAVATION LOG
Classification Symbol & Soil Name Classification of material and its description is based on the Unified Classification System as referenced in AS1726 – 1993 Geotechnical Site Investigations, Appendix A. A summary of the more common terms is included within. Particle Size Descriptive Terms
Name Subdivision Size
Boulders >200mm
Cobbles 63 – 200mm
Gravel Coarse 20 – 63mm
Medium 6 – 20mm
Fine 2.36 – 6mm
Sand Coarse 0.6 – 2.36mm
Medium 200 – 600 micron
Fine 75 – 200 micron
Silt 2 – 75 micron
Clay < 2 micron
Consistency of Cohesive Soils
Term Undrained shear strength,
su (kPa)
Field Guide
Very Soft (VS)
<12 A finger can be pushed well into the soil with little effort
Soft (S)
12 – 25 A finger can be pushed into the soil to about 25mm depth
Firm (F)
25 – 50 The soil can be indented about 5mm with the thumb
Stiff (St)
50 – 100 The surface of the soil can be indented with the thumb
Very Stiff (VSt)
100 – 200 The surface of the soil can be indented by thumb nail
Hard (H)
>200 The surface of the soil can be marked only with the thumbnail
Friable (F)
- Crumbles or powders when scraped by thumbnail
Density of Granular Soils
Term Density Index (%)
Very Loose (VL) < 15
Loose (L) 15 – 35
Medium Dense (MD) 35 – 65
Dense (D) 65 – 85
Very Dense (VD) > 85
Minor Components
Term Field Guide Proportion of Minor Component In:
Trace of Presence just detectable by feel or eye
Coarse grained soils: <5% Fine grained soils: <15%
Some Presence easily detectable by feel or eye
Coarse grained soils: 5-12% Fine grained soils: 15-30%
Moisture Condition Dry (D) Looks & feels dry. Cohesive soils are usually
hard, powdery or friable. Granular soils run freely through the hand.
Moist (M) Soil feels cool and darkened in colour. Cohesive soils can be moulded. Granular soils tend to cohere. Free water does not form.
Wet (W) As for moist, but with free water forming on hands when remoulded.
Method S Auger Screwing D Auger Drilling R Roller/tricone
W Washboring N Natural Exposure E Existing Excavation
B Blade/bucket C Coring H Hammer Drill
Support * Nil C Casing M Mud/polymer
Water * Not observed Observed water level (date shown) Observed water inflow Observed water outflow R Refer to report for details Structures, Additional Observations PP Pocket Penetrometer test (kPa) DCP Dynamic Cone Penetrometer test (blows/100mm)
Notes, Samples, Tests U63 Undisturbed sample, 63mm diameter D Disturbed sample N* Standard Penetration Test, (*) Sample Figure = results Surface Known boundary - - - - - - - - - - Probably boundary -?-?-?-?-?-?- Possible boundary