Upload
duongtu
View
212
Download
0
Embed Size (px)
Citation preview
2H
2H
2H
2H
2H
2H
2H
2H
2H
2H
2H
2H
2H
2H
2H
2H
0.1
1
1
3
3
4
7
8
8
9
9
10
10
2.1
3.1
E
F
G
H
CC
DD
EE
FF
5
8.1 8.2
3.3
120B120A
130A
129A
128A
127A
141A
142A
126A
132B
132A
142
149
C
A4.02
1404 SF120
INTERDISCIPLINARYLAB
848 SF132
STUDENTLOUNGE
268 SF131
STUDENTBREAKROOM
866 SF126
LIBRARY
159 SF130
STUDYROOM
168 SF129
STUDYROOM
157 SF128
SECURITY142 SF127
MAINTENANCE
232 SF141
WOMEN WCFIRST LEVEL
120 SF123
ELEC. ROOM
ELEVATOR
97 SF124
ENTRANCEFACILITY
40 SF122
JANITOR
137 SF121
BLDG SERV.
A3.02
1
A3.02
3
A3.02
4
A3.02
2
A3.027
A3.02
6
A3.01
1
A3.02
5
A3.02
8
A
A4.01
a
A4.01
A
A4.02
B
A4.02
PLUMBING CHASE
41
'-6"
10
'-0"
30'-1
0"
14'-9" 16'-3" 30'-10"
30'-0"
13'-6"
3'-10"
7'-6"
1'-5"
24'-10"
2
A4.12
234 SF142
MEN WCFIRST LEVEL
8.4
F.4
3.4
125A
17 SF125
FIRE RISERROOM
124A
126B
G.3
G.4
STAIR #3
22'-10"
8'-0"
17'-6"
13'-6"
123A
121A
131A
133A
72 SF133
ELEV. MECH.
461
9"11"
A6.507 8
A6.50
5
A6.50
6
MKBD-3
14
MK
BD
-2
MK
BD
-24
A4.12
3
A4.12
5
A4.12
ELECTRIC VEHICLECHARGER STATION
A1.202
A1.20
3
115' - 10"
5'-6" 7'-6" 18'-0" 30'-10"
61'-10"
61'-10"
82
'-4"
A3
A3
H3
D6
D3
D3
D3
D6 D6HL3
A3
A3
HL3
D6
D6
UL6
UL6
A3
56'-3"
B6
A6
A5.201
MATCHLINE A2.01N
A5.20
69
78
FLOOR PLAN GENERAL NOTES
SEE SHEET A6.60 FOR TYPICAL EXTERIOR AND INTERIOR WALLTYPES.C. ALL PIPING, CONDUITS AND RELATED MECHANICAL ANDELECTRICAL ITEMS SHALL BE CONCEALED WITHIN DRYWALLFURRING AS REQUIRED IN FINISHED AREAS WHETHER SHOWN ON
DRAWINGS OR NOT, UNO.D. PROVIDE METAL PLATE BACKING IN WALLS WHERE WALL-MOUNTED EQUIPMENT IS SHOWN ON PLANS OR ELEVATIONS.VERIFY HEIGHT AND LENGTH WITH ACTUAL EQUIPMENT.REFERENCE 1G/S106 FOR BACKING TYPE.E. VERIFY EXISTING DIMENSIONS, CONDITIONS AND FINISHESBEFORE PRICING AND/OR PROCEEDING WITH WORK.DISCREPANCIES SHALL BE BROUGHT TO THE ARCHITECT'S
ATTENTION IMMEDIATELY.F. ALL DIMENSIONS ARE CLEAR FROM THE FACE OF FINISHEDWALL/PARTITION TO FACE OF FINISHED WALL/PARTITION ORFACE OF EXISTING WALLS. SEE PARTITION TYPES FOR ACTUALTHICKNESS OF PARTITIONS. MASONRY WALLS ARE DIMENSIONEDTO NOMINAL FACE.G. MATCH FINISHED WALL OR PARTITION THICKNESS WHERE NEWWALLS OR PARTITIONS OCCUR IN LINE WITH EXISTING WALLS.
H. PATCH ALL HOLES IN EXISTING SURFACES WHERE EQUIPMENTHAS BEEN REMOVED OR DEMOLITION HAS OCCURRED. PREPARESURFACES AS REQUIRED FOR NEW FINISHES. PATCH TO MATCHADJACENT SURFACE IF NOT SCHEDULED.I.ALL EXISTING FLOOR OPENINGS AND DEPRESSIONS IN THEWORK SHALL BE FILLED OR CLOSED, UNO, WITH MATERIALS TOMATCH ADJACENT SURFACES, FINISHES AND FIRE RATINGS.J. REFER TO SHEET A000 FOR TYPICAL RATED PENETRATION
DETAILSK. FOR GLAZING TYPES AT BUILDING EXTERIOR - SEE BUILDINGELEVATIONS AND SHEET A000 AND A000L. ALL FREESTANDING FURNITURE TO BE PROVIDED ANDINSTALLED BY OWNER U.N.IM. REFER TO DETAILS A000 AND A000 FOR OPENING DETAILSN. ALL MECHANICAL EQUIPMENT PADS TO BE 1'-4"HIGH UNLESSOTHERWISE NOTED. LENGTH AND WIDTH OF PADS TO BE
VERIFIED BY CONTRACTOR.O. REFER TO SHEET A660 AND A661 FOR ACOUSTICAL PARTITIONTYPE AND DETAILP. PATCH WALLS WHERE CONNECTIONS OF ELECTRICAL AND ORDATA/COMMUNICATION OUTLETS ARE BEING REMOVED.Q. SEE SHEETS A000 AND A000 FOR TYPICAL CEILING DETAILS.R. NOT USED.S. REF SPECIFICATION AND DRAWINGS FOR ALTERANTES
T. REF A000 AND A000 FOR CASEWORK DETAILS, AND REFERENCEA600 FOR TYPICAL MOUNTING HEIGHTS.U. ALL INTERIOR PARTITIONS AND DRYWALL CEILING SHALL BEPAINTED AS <PT-1 > UNO.V. PROVIDE ALL NEW FIRE EXTINGUISHER PER FLOOR PLAN &ELEVATION. CONTRACTOR TO VERIFY LOCATION & TYPEW. PROVIDE (N) WALL BASE THROUGHOUT AG BUILDING ATLOCATIONS MISSING WALL BASE, COLOR & TYPE TO MATCH
EXISTINGX. REFERENCE A421 FOR TYPICAL CMU MODULE, AND COURSEINFORMATION.Y. PROVIDE ON ALL EXTEIROR WINDOW. UNO.
A. VERIFY DIMENSIONS, CONDITIONS & FINISHES BEFORE PRICING&/OR PROCEEDING WITH WORK. DISCREPANCIES SHALL BEBROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY.
B. ALL EXTERIOR WALL ARE TYPE MB U.N.O.
ALL INTERIOR WALL ARE TYPE B3 U.N.O.
xxx
WALL RATINGS
1 HR RATED CONSTRUCTION
FLOOR PLAN LEGEND
FLOOR DRAIN PER PLUMBINGDRAWINGS
NOTES AND SYMBOLS
MB EXTERIOR WALL TYPE, SEE SHEETA6.60 FOR DETAILS
WX EXTERIOR WINDOW TYPE, SEEA0.82
DOOR NUMBER, SEE A0.80 FORDOOR SCHEDULE1
01A
1BRATING
1 ...
FLOOR PLAN KEY NOTES
2
NOTE:...
B3 INTERIOR WALL TYPE, SEE SHEETA6.60 FOR DETAILS
....
3 .....
PH PANIC HARDWARE
S a n t a M o n i c a , C a l i f o r n i a U S A 9 0 4 0 5
1 9 1 8 M a i n S t r e e t
H a m m e l , G r e e n a n d A b r a h a m s o n , I n c .
A r c h i t e c t u r e | E n g i n e e r i n g | P l a n n i n g
T e l e p h o n e 3 1 0 . 5 5 3 . 6 8 8 8 F a c s i m i l e 3 1 0 . 5 5 3 . 1 6 6 8
I D E N T I F I C A T I O N S T A M P
D I V I S I O N O F
T H E S T A T E A R C H I T E C T
SSS DATE
FILE #
AC FLS
APPL #
NORTH NORTH NORTH NORTH
DRAWN BY
DATE
SCALE
HGA COMM. NO.
C COPYRIGHT HAMMEL, GREEN AND ABRAHAMSON, INC.
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORTWAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM A DULY LICENSED ARCHITECT UNDER THELAWS OF THE STATE OF
NAME:DATE:REGISTRATION NUMBER:
NOT F
OR
CONSTRUCTIO
N
PROJECT
SHEET NUMBER
SHEET TITLE
KEY PLAN
ISSUE
AGENCY APPROVAL
REGISTRATION STAMP
Local ArchitectO2 Architecture 760.778.8165
StructuralSaiful Bouquet 626.304.2616
Mechanical / Plumbing / ElectricalHGA Inc. 612.758.4000
CivilMSA Consulting 760.320.9811
LandscapeRGA Landscape Architects 760.568.3624
AcousticalNewson Brown Acoustics 310.829.6343
Audio Visual, Technology, SecuritySextant Group 480.831.8580
Code / Fire ProtectionRolf Jensen & AssociateInc.
310.782.0850
Food Service ConsultingCini-Little International,Inc.
626.441.7700
Graphics & Signage ConsultingDavies Associates 310.247.9572
Hardware ConsultingFinish Hardware Consulting 818.387.6083
MARK DATE DESCRIPTION
02.01.1202.01.1202.01.1202.01.12 SSSSDDDD PPPPRRRROOOOGGGGRRRREEEESSSSSSSS PPPPRRRRIIIINNNNTTTT
02.14.1202.14.1202.14.1202.14.12 100% SD PRINT100% SD PRINT100% SD PRINT100% SD PRINT
4201 N. INDIAN CANYON DR.PALM DESERT, CA 92262
04.20.1204.20.1204.20.1204.20.12 DDDDDDDD PPPPRRRROOOOGGGGRRRREEEESSSSSSSS PPPPRRRRIIIINNNNTTTT
06.05.1206.05.1206.05.1206.05.12 100% DD100% DD100% DD100% DD
1/8" = 1'-0"
6/4
/2012 3
:02:5
0 P
MC
:\U
sers
\lsro
drigoe
\Do
cum
ents
\Revit L
oca
l File
s\3
18
8-0
01
-00 C
OD
WV
C P
H1 B
LD
G C
OM
PLE
X_ls
rodrigoe-P
C6339.r
vt
Commission Number
Author
SOUTH BUILDING PARTIAL -FIRST LEVEL FLOOR PLAN
A2.01S
name and phone
PHASE 01 BUILDINGCOMPLEX
100% DD 06/05/2012
COLLEGE OF THE DESERTWEST VALLEY CAMPUS
DESIGN DEVELOPMENT
100% DD 06/05/2012
1/8" = 1'-0"1SOUTH BUILDING PARTIAL - FIRST LEVEL FLOOR PLAN