Transcript

2H

2H

2H

2H

2H

2H

2H

2H

2H

2H

2H

2H

2H

2H

2H

2H

0.1

1

1

3

3

4

7

8

8

9

9

10

10

2.1

3.1

E

F

G

H

CC

DD

EE

FF

5

8.1 8.2

3.3

120B120A

130A

129A

128A

127A

141A

142A

126A

132B

132A

142

149

C

A4.02

1404 SF120

INTERDISCIPLINARYLAB

848 SF132

STUDENTLOUNGE

268 SF131

STUDENTBREAKROOM

866 SF126

LIBRARY

159 SF130

STUDYROOM

168 SF129

STUDYROOM

157 SF128

SECURITY142 SF127

MAINTENANCE

232 SF141

WOMEN WCFIRST LEVEL

120 SF123

ELEC. ROOM

ELEVATOR

97 SF124

ENTRANCEFACILITY

40 SF122

JANITOR

137 SF121

BLDG SERV.

A3.02

1

A3.02

3

A3.02

4

A3.02

2

A3.027

A3.02

6

A3.01

1

A3.02

5

A3.02

8

A

A4.01

a

A4.01

A

A4.02

B

A4.02

PLUMBING CHASE

41

'-6"

10

'-0"

30'-1

0"

14'-9" 16'-3" 30'-10"

30'-0"

13'-6"

3'-10"

7'-6"

1'-5"

24'-10"

2

A4.12

234 SF142

MEN WCFIRST LEVEL

8.4

F.4

3.4

125A

17 SF125

FIRE RISERROOM

124A

126B

G.3

G.4

STAIR #3

22'-10"

8'-0"

17'-6"

13'-6"

123A

121A

131A

133A

72 SF133

ELEV. MECH.

461

9"11"

A6.507 8

A6.50

5

A6.50

6

MKBD-3

14

MK

BD

-2

MK

BD

-24

A4.12

3

A4.12

5

A4.12

ELECTRIC VEHICLECHARGER STATION

A1.202

A1.20

3

115' - 10"

5'-6" 7'-6" 18'-0" 30'-10"

61'-10"

61'-10"

82

'-4"

A3

A3

H3

D6

D3

D3

D3

D6 D6HL3

A3

A3

HL3

D6

D6

UL6

UL6

A3

56'-3"

B6

A6

A5.201

MATCHLINE A2.01N

A5.20

69

78

FLOOR PLAN GENERAL NOTES

SEE SHEET A6.60 FOR TYPICAL EXTERIOR AND INTERIOR WALLTYPES.C. ALL PIPING, CONDUITS AND RELATED MECHANICAL ANDELECTRICAL ITEMS SHALL BE CONCEALED WITHIN DRYWALLFURRING AS REQUIRED IN FINISHED AREAS WHETHER SHOWN ON

DRAWINGS OR NOT, UNO.D. PROVIDE METAL PLATE BACKING IN WALLS WHERE WALL-MOUNTED EQUIPMENT IS SHOWN ON PLANS OR ELEVATIONS.VERIFY HEIGHT AND LENGTH WITH ACTUAL EQUIPMENT.REFERENCE 1G/S106 FOR BACKING TYPE.E. VERIFY EXISTING DIMENSIONS, CONDITIONS AND FINISHESBEFORE PRICING AND/OR PROCEEDING WITH WORK.DISCREPANCIES SHALL BE BROUGHT TO THE ARCHITECT'S

ATTENTION IMMEDIATELY.F. ALL DIMENSIONS ARE CLEAR FROM THE FACE OF FINISHEDWALL/PARTITION TO FACE OF FINISHED WALL/PARTITION ORFACE OF EXISTING WALLS. SEE PARTITION TYPES FOR ACTUALTHICKNESS OF PARTITIONS. MASONRY WALLS ARE DIMENSIONEDTO NOMINAL FACE.G. MATCH FINISHED WALL OR PARTITION THICKNESS WHERE NEWWALLS OR PARTITIONS OCCUR IN LINE WITH EXISTING WALLS.

H. PATCH ALL HOLES IN EXISTING SURFACES WHERE EQUIPMENTHAS BEEN REMOVED OR DEMOLITION HAS OCCURRED. PREPARESURFACES AS REQUIRED FOR NEW FINISHES. PATCH TO MATCHADJACENT SURFACE IF NOT SCHEDULED.I.ALL EXISTING FLOOR OPENINGS AND DEPRESSIONS IN THEWORK SHALL BE FILLED OR CLOSED, UNO, WITH MATERIALS TOMATCH ADJACENT SURFACES, FINISHES AND FIRE RATINGS.J. REFER TO SHEET A000 FOR TYPICAL RATED PENETRATION

DETAILSK. FOR GLAZING TYPES AT BUILDING EXTERIOR - SEE BUILDINGELEVATIONS AND SHEET A000 AND A000L. ALL FREESTANDING FURNITURE TO BE PROVIDED ANDINSTALLED BY OWNER U.N.IM. REFER TO DETAILS A000 AND A000 FOR OPENING DETAILSN. ALL MECHANICAL EQUIPMENT PADS TO BE 1'-4"HIGH UNLESSOTHERWISE NOTED. LENGTH AND WIDTH OF PADS TO BE

VERIFIED BY CONTRACTOR.O. REFER TO SHEET A660 AND A661 FOR ACOUSTICAL PARTITIONTYPE AND DETAILP. PATCH WALLS WHERE CONNECTIONS OF ELECTRICAL AND ORDATA/COMMUNICATION OUTLETS ARE BEING REMOVED.Q. SEE SHEETS A000 AND A000 FOR TYPICAL CEILING DETAILS.R. NOT USED.S. REF SPECIFICATION AND DRAWINGS FOR ALTERANTES

T. REF A000 AND A000 FOR CASEWORK DETAILS, AND REFERENCEA600 FOR TYPICAL MOUNTING HEIGHTS.U. ALL INTERIOR PARTITIONS AND DRYWALL CEILING SHALL BEPAINTED AS <PT-1 > UNO.V. PROVIDE ALL NEW FIRE EXTINGUISHER PER FLOOR PLAN &ELEVATION. CONTRACTOR TO VERIFY LOCATION & TYPEW. PROVIDE (N) WALL BASE THROUGHOUT AG BUILDING ATLOCATIONS MISSING WALL BASE, COLOR & TYPE TO MATCH

EXISTINGX. REFERENCE A421 FOR TYPICAL CMU MODULE, AND COURSEINFORMATION.Y. PROVIDE ON ALL EXTEIROR WINDOW. UNO.

A. VERIFY DIMENSIONS, CONDITIONS & FINISHES BEFORE PRICING&/OR PROCEEDING WITH WORK. DISCREPANCIES SHALL BEBROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY.

B. ALL EXTERIOR WALL ARE TYPE MB U.N.O.

ALL INTERIOR WALL ARE TYPE B3 U.N.O.

xxx

WALL RATINGS

1 HR RATED CONSTRUCTION

FLOOR PLAN LEGEND

FLOOR DRAIN PER PLUMBINGDRAWINGS

NOTES AND SYMBOLS

MB EXTERIOR WALL TYPE, SEE SHEETA6.60 FOR DETAILS

WX EXTERIOR WINDOW TYPE, SEEA0.82

DOOR NUMBER, SEE A0.80 FORDOOR SCHEDULE1

01A

1BRATING

1 ...

FLOOR PLAN KEY NOTES

2

NOTE:...

B3 INTERIOR WALL TYPE, SEE SHEETA6.60 FOR DETAILS

....

3 .....

PH PANIC HARDWARE

S a n t a M o n i c a , C a l i f o r n i a U S A 9 0 4 0 5

1 9 1 8 M a i n S t r e e t

H a m m e l , G r e e n a n d A b r a h a m s o n , I n c .

A r c h i t e c t u r e | E n g i n e e r i n g | P l a n n i n g

T e l e p h o n e 3 1 0 . 5 5 3 . 6 8 8 8 F a c s i m i l e 3 1 0 . 5 5 3 . 1 6 6 8

I D E N T I F I C A T I O N S T A M P

D I V I S I O N O F

T H E S T A T E A R C H I T E C T

SSS DATE

FILE #

AC FLS

APPL #

NORTH NORTH NORTH NORTH

DRAWN BY

DATE

SCALE

HGA COMM. NO.

C COPYRIGHT HAMMEL, GREEN AND ABRAHAMSON, INC.

I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORTWAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM A DULY LICENSED ARCHITECT UNDER THELAWS OF THE STATE OF

NAME:DATE:REGISTRATION NUMBER:

NOT F

OR

CONSTRUCTIO

N

PROJECT

SHEET NUMBER

SHEET TITLE

KEY PLAN

ISSUE

AGENCY APPROVAL

REGISTRATION STAMP

Local ArchitectO2 Architecture 760.778.8165

StructuralSaiful Bouquet 626.304.2616

Mechanical / Plumbing / ElectricalHGA Inc. 612.758.4000

CivilMSA Consulting 760.320.9811

LandscapeRGA Landscape Architects 760.568.3624

AcousticalNewson Brown Acoustics 310.829.6343

Audio Visual, Technology, SecuritySextant Group 480.831.8580

Code / Fire ProtectionRolf Jensen & AssociateInc.

310.782.0850

Food Service ConsultingCini-Little International,Inc.

626.441.7700

Graphics & Signage ConsultingDavies Associates 310.247.9572

Hardware ConsultingFinish Hardware Consulting 818.387.6083

MARK DATE DESCRIPTION

02.01.1202.01.1202.01.1202.01.12 SSSSDDDD PPPPRRRROOOOGGGGRRRREEEESSSSSSSS PPPPRRRRIIIINNNNTTTT

02.14.1202.14.1202.14.1202.14.12 100% SD PRINT100% SD PRINT100% SD PRINT100% SD PRINT

4201 N. INDIAN CANYON DR.PALM DESERT, CA 92262

04.20.1204.20.1204.20.1204.20.12 DDDDDDDD PPPPRRRROOOOGGGGRRRREEEESSSSSSSS PPPPRRRRIIIINNNNTTTT

06.05.1206.05.1206.05.1206.05.12 100% DD100% DD100% DD100% DD

1/8" = 1'-0"

6/4

/2012 3

:02:5

0 P

MC

:\U

sers

\lsro

drigoe

\Do

cum

ents

\Revit L

oca

l File

s\3

18

8-0

01

-00 C

OD

WV

C P

H1 B

LD

G C

OM

PLE

X_ls

rodrigoe-P

C6339.r

vt

Commission Number

Author

SOUTH BUILDING PARTIAL -FIRST LEVEL FLOOR PLAN

A2.01S

name and phone

PHASE 01 BUILDINGCOMPLEX

100% DD 06/05/2012

COLLEGE OF THE DESERTWEST VALLEY CAMPUS

DESIGN DEVELOPMENT

100% DD 06/05/2012

1/8" = 1'-0"1SOUTH BUILDING PARTIAL - FIRST LEVEL FLOOR PLAN