XC14
P.2
XCR
XCP
XCN
2
30-A01
3' - 0" 10' - 0"
45' -
0"
12' -
0"
9' -
6"
9' -
6"
30-A015
6'-0"W X 6'-8"H
INSULATED METAL
DOORS AND FRAME
MANUFACTURED
STORAGE BUILDING
EXISTING METAL
PANEL SYSTEM
EXISTING 2'-0" THICK
CONCRETE WALL
EXISTING 2-HR RATED
WALL ASSEMBLY
EXISTING 90-MINUTE
RATED DOORS TO
REMAIN
EXIST. CONCRETE PAVINGEXIST. GRAVEL
DEMO EXISTING
CONCRETE PAVING IN
HATCHED AREA.
EXISTING BOLLARD
TO REMAIN, TYPICAL
4" SLAB w/ 6x6~W4xW4 WWF
ON 6" COMPACTED FREE
DRAINING GRANULAR FILL.
B03 - BALLROOM-51' - 2 3/8"
B04 - SERVICE PLATFORM-67' - 7 1/4"
XC14
1' -
9"
8' -
6"
EXISTING 2'-0" THICK
CONCRETE WALL
MANUFACTURED STORAGE
BUILDING
EXISTING CURTAIN WALL
SYSTEM
6' -
6"
5K, MIN 26 GA, GALVALUME
GUTTER, PAINT TO MATCH
SIDING
10' - 0"
10' -
3"
CONCRETE PAD AND FOOTER30-A01
3 TYP
B04 - SERVICE PLATFORM-67' - 7 1/4"
XCPXCN
2
30-A01
PROJECT DESCRIPTION:
TO ADD MANUFACTURED SHEDS ON THE B4 LEVEL
SITE INFORMATION:
PP NO: 101-60- (17,18,19 20, 24,25, 36)
300 LAKESIDE AVE, CLEVELAND, OH 44113
APPLICABLE CODES:
2017 OHIO BUILDING CODE W/2017 UPDATES
2017 NATIONAL ELECTRIC CODE
2017 OHIO FIRE CODE
2012 INTERNATIONAL ENERGY EFFICIENCY CODE
CODE SUMMARY:
USE CLASSIFICATION
SECTION 311 S-1
GENERAL EXISTING BUILDING DATA
SECTION 602 TYPE OF CONSTRUCTION 2B
BUILDING FIRE RESISTANCE RATINGS FOR EXTERIOR WALLS
TABLE 602 FIRE RATING OF EXTERIOR WALL BASED ON SEPARATION DISTANCE
X < 5' 2 HOUR FOR S-1
PROJECT AREA
STORAGE SHED ADDITION: 450 SF
SITE LOCATION MAPN
LIFE SAFETY SUMMARY
30-A01 URBAN FARM STORAGE BUILDING ADDITION
30-E01 URBAN FARM STORAGE BUILDING ELECTRICAL PLAN
DRAWING INDEX
GLOBAL CENTER FOR HEALTH INNOVATION ABOVE
STORAGE SHED
HUNTINGTON CONVENTION CENTER OF CLEVELAND
OCCUPIED AREASUNEXCAVATED AREA
SMG
1 ST CLAIR AVENUE, NE
MEZZANINE LEVEL
CLEVELAND, OH 44114
STRUCTURAL ENGINEER
CLIENT
RICHARD L. BOWEN & ASSOCIATES INC.
13000 SHAKER BOULEVARD
CLEVELAND, OHIO 44120
216.491.9300 (PH)
216.491.8053 (FX)
Contact Person: JEFF GRAHAM
ELECTRICAL ENGINEERRICHARD L. BOWEN & ASSOCIATES INC.
13000 SHAKER BOULEVARD
CLEVELAND, OHIO 44120
216.491.9300 (PH)
216.491.8053 (FX)
Contact Person: JACK MCNEELY
BUILDING OWNERCUYAHOGA COUNTY CONVENTION FACILITES
DEVELOPMENT CORPORATION
1 ST. CLAIR AVENUE, NE
3RD FLOOR
CLEVELAND, OH 44114
RICHARD L. BOWEN & ASSOCIATES INC.
13000 SHAKER BOULEVARD
CLEVELAND, OHIO 44120
216.491.9300 (PH)
216.491.8053 (FX)
Contact Person: KEN CHOW
ARCHITECT
PROJECT TEAM
30-A01
1
PROPOSED STORAGE SHED
EXISTING CONCRETE
WALKWAY TO REMAIN
EXISTING BOLLARD TO
REMAIN, TYPICAL
EXISTING RETAINING WALL
AND FENCE TO REMAIN,
TYPICAL
EXISTING WATER FEATURE
EXISTING LIVESTOCK
FEEDER/WATERER
EXISTING CHICKEN COOP
RS
WPG
2-#10, 1-#10 GND IN 3/4" C
1
RS-6
WPG
2-#10, 1-#10 GND IN 3/4" C
1
RS-4
2' - 0"4'
- 0
"
8"
(2)-#5 CONT.
TOP & BOT.
CONC. SLAB - SEE PLAN
PRE-FABRICATED BUILDING WALL,
BASE ANGLE AND ATTACHMENT BY
PRE-ENGINEERED BUILDING
SUPPLIERS
#4 2'-0"x2'-0" @ 1'-6" O.C.
4. BUILDING CODE: 2017 OHIO BUILDING CODE (OBC)
SITE CLASS ................................................................................................................................................................ D
Ss .......................................................................................................................................................................... 0.172
S1 .......................................................................................................................................................................... 0.057
GENERAL
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN, INSTALLATION, AND THE FINAL CLEARANCE OF
ANY TEMPORARY NEEDLING, UNDERPINNING, SHORING, OR BRACING OF EXISTING STRUCTURES.
7. CONSTRUCTION LOADS SHALL NOT EXCEED DESIGN LIVE LOADS. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR ALL DESIGN REQUIRED TO SUPPORT CONSTRUCTION EQUIPMENT USED IN
CONSTRUCTING THIS PROJECT. SHORING AND RESHORING IS THE RESPONSIBILITY OF THE CONTRACTOR.
1. COORDINATE WITH ALL DRAWINGS FOR INFORMATION RELATED TO STRUCTURAL WORK. ANY CHANGES TO
THE BUILDING STRUCTURAL SYSTEM SHALL BE REDESIGNED ONLY BYRICHARD L. BOWEN + ASSOCIATES, INC.
ALL CHANGES MUST HAVE PRIOR AUTHORIZATION OF THE OWNER AND RICHARD L. BOWEN + ASSOCIATES, INC.
2. ALL CONTRACTORS SHALL COORDINATE WITH ALL DRAWINGS WITHIN THE CONTRACT DOCUMENTS.
3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND CONDITIONS RELATED TO EXISTING
CONSTRUCTION, EXISTING SERVICES, AND THE SITE BEFORE BEGINNING WORK.
17. ALL WALL FOOTING REINFORCING SHALL RUN CONTINUOUS THROUGH COLUMN FOOTINGS.
18. BEND ALL HORIZONTAL BARS AROUND ADJACENT CORNERS AND LAP ACCORDING TO TABLE #1.
19. BONDBREAKER MATERIAL SHALL BE 15 POUND FELT PAPER.
14. CHAMFER EXPOSED EDGES OF CONCRETE 3/4", UNLESS NOTED OTHERWISE.
15. PROVIDE CONTROL JOINTS IN ALL SLABS ON GRADE AS SHOWN ON DRAWINGS.
5. DESIGN LOADS:
SEISMIC DESIGN DATA:
OCCUPANCY CATEGORY............................................................................................................................................ I
ROOF LIVE LOAD................................................................................................................................................ 20 PSF
GROUND SNOW LOAD ............................................................................................................................ Pg=30.0 PSF
FLAT ROOF SNOW LOAD .................................................................................................................. Pf=21.0 + DRIFT
ROOF SNOW LOAD:
FLOOR LIVE LOAD............................................................................................................................................ 100 PSF
SEISMIC IMPORTANCE FACTOR ....................................................................................................................... Ie=1.0
SLABS ON GRADE (WELDED WIRE FABRIC).......................................................1/3 SLAB THICKNESS FROM TOP OF SLAB
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH..............................................................................3"
LOCATION CLEARANCE
TYPICAL REINFORCING BAR CLEARANCE TABLE.
WIND DESIGN DATA:
MINIMUM LAP SPLICE AND ANCHORAGE DIMENSION TABLE #1
BAR SIZE
1. WHEN LAPPING TWO DIFFERENT SIZE BARS, USE THE LAP DIMENSION OF THE SMALLER BAR OR
THE ANCHORAGE DIMENSION OF THE LARGER BAR. USE WHICHEVER DIMENSIONIS LARGER.
#5
#4
#6
#3
Fy = GRADE 60, NON-COATED BARS
32"
22"
43"
16"
3000 PSI CONCRETE
OTHER BARS
34"
26"
17"
43"
33"
22"
16" 13"
TOP BARS
56"
42"
29"
#5
#4
#6
#3 21"
LAP ANCHORAGE ANCHORAGELAPBAR SIZE
8. IF THE FABRICATOR HAS BEEN AUTHORIZED TO USE THE ARCHITECT AND ENGINEER'S DRAWINGS AS
ERECTION DRAWINGS, THE FABRICATOR MUST REMOVE ALL TITLE BLOCKS, PROFESSIONAL SEALS AND ANY
OTHER REFERENCES TO THE ARCHITECT AND ENGINEER FROM THAT ERECTION DRAWING. THE
FABRICATOR'S NAME AND TITLE SHALL BE PLACED ON THE ERECTION DRAWINGS.
CAST-IN-PLACE CONCRETE
1. CAST IN PLACE CONCRETE SHALL CONFORM TO THE LATEST ACI 318 & 350 CODE, STANDARDS AND ACI 301
"STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE", EXCEPT AS MODIFIED HEREIN.
2. SUBMIT LABORATORY TEST REPORTS FOR CONCRETE MATERIALS AND PROPOSED MIX DESIGN TESTS
AND DATA.
3. MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE IN 28 DAYS SHALL BE:
3000 PSI - SPREAD FOOTINGS: MINIMUM CEMENT CONTENT OF 470 LB/CUBIC YARD; WC .50
3500 PSI - INTERIOR SLAB: MINIMUM CEMENT CONTENT OF 517 LB/CUBIC YARD; WC .44
4500 PSI - ALL OTHER CONCRETE MINIMUM CEMENT CONTENT OF 564 LB/CUBIC YARD; WC .45
4. REINFORCING BARS: A615 GRADE 60 KSI YIELD STRENGTH, UNLESS NOTED OTHERWISE. WELDING OR TACK
WELDING A615 BARS SHALL NOT BE PERMITTED.
5. REINFORCING BARS FOR WELDED APPLICATIONS SHALL CONFORM WITH A706, 60 KSI YIELD STRENGTH.
6. WELDED WIRE FABRIC: ASTM A185, FLAT SHEET. ROLLED WWF SHALL NOT BE PERMITTED.
7. CALCIUM CHLORIDE SHALL NOT BE PERMITTED NOR SHALL ANY ADMIXTURE CONTAINING CALCIUM
CHLORIDE BE PERMITTED.
8. ALL CONCRETE SHALL CONTAIN A WATER REDUCING ADMIXTURE CONFORMING TO ASTM C494, TYPE A, F OR G.
9. ALL CONCRETE EXPOSED TO THE WEATHER OR IN A LOCATION VULNERABLE TO DEICERS SHALL CONTAIN
AN AIR-ENTRAINED ADMIXTURE CONFORMING TO ASTM C260. THE AMOUNT OF ENTRAINED AIR SHALL BE
6% ± 1%.
10. CONCRETE SHALL BE DISCHARGED AT THE SITE WITHIN 1 1/2 HOURS AFTER WATER HAS BEEN ADDED TO
THE CEMENT AND AGGREGATES. ADDITION OF WATER TO THE MIX AT THE PROJECT SITE WILL NOT BE
PERMITTED. ALL WATER MUST BE ADDED AT THE BATCH PLANT. SLUMP MAY BE ADJUSTED ONLY THROUGH
THE USE OF ADDITIONAL WATER REDUCING ADMIXTURE OR HIGH RANGE WATER REDUCING ADMIXTURE.
11. PRECAST CONCRETE CUBES OR SAND PLATE CHAIRS SHALL BE USED FOR THE SUPPORT OF
REINFORCING ON GRADE. CONCRETE BLOCK OR CLAY MASONRY BRICK ARE NOT PERMITTED.
12. CONSTRUCTION JOINTS SHALL BE SUBJECT TO REVIEW BY RICHARD L. BOWEN + ASSOCIATES, INC., AND
SHALL BE LOCATED AND DETAILED AS SPECIFIED ON THE DRAWINGS OR AS NOTED.
13. ALL WELDED WIRE FABRIC SHALL BE CHAIRED TO ITS PROPER HEIGHT AND MAINTAINED AT THE PROPER
HEIGHT THROUGHOUT THE CONCRETE PLACING OPERATION. LIFTING OF WELDED WIRE FABRIC WITH A
HOOK DURING CONCRETE PLACEMENT SHALL NOT BE PERMITTED.
16. TOP LAYER OF REINFORCING STEEL IN FOOTINGS SHALL BE CONSIDERED TO BARS REGARDLESS OF
THICKNESS OF CONCRETE BELOW THE BARS.
20. DETERMINE SIZE AND LOCATION OF MECHANICAL EQUIPMENT AND MAKE PROVISIONS FOR BOLTS,
SLEEVES, PADS, ETC., IN ACCORDANCE WITH THE MANUFACTURER'S CERTIFIED DRAWINGS. THIS WORK
SHALL BE COORDINATED WITH THE TRADES INVOLVED PRIOR TO ANY CONCRETE PLACEMENT.
21. REINFORCING BAR LAP SPLICES AND ANCHORAGE LENGTH SHALL CONFORM WITH "MINIMUM LAP
SPLICE AND ANCHORAGE DIMENSION TABLE #1" UNLESS NOTED OTHERWISE ON THE DRAWINGS.
BASIC WIND SPEED .............................................................................................................................V = 105 MPH
OCCUPANCY CATEGORY.................................................................................................................. CATEGORY I
WIND EXPOSURE ................................................................................................................................................... B
SNOW LOAD IMPORTANCE FACTOR .............................................................................................................. Is = 0.8
SNOW EXPOSURE FACTOR ........................................................................................................................... Ce = 1.0
SNOW THERMAL FACTOR ............................................................................................................................... Ct = 1.0
1. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE SURVEY BEFORE BEGINNING CONSTRUCTION.
2. DESIGN SOIL BEARING PRESSURE IS 1000 PSF ASSUMED. FROST DEPTH IS 42".
3. SOIL SUITABILITY AND BEARING CAPACITY SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION.
5. NOTIFY THE ARCHITECT AS SOON AS POSSIBLE OF ANY UNUSUAL SOIL CONDITIONS.
6. SET FOUNDATIONS AT ELEVATIONS SHOWN, OR ON FIRM MATERIAL OF DESIGN BEARING CAPACITY,
WHICHEVER IS LOWER.
A. ALL SOIL SURROUNDING AND UNDER ALL FOOTINGS, FLOOR SLABS, ETC. SHALL BE PROTECTED
FROM FREEZING AND FROST ACTION DURING CONSTRUCTION.
B. WHERE FOOTINGS ARE IN CLOSE PROXIMITY OF SEWERS, DRAINS, CONDUITS, UNDERFLOOR PIPES,
ETC., BOTTOM OF ALL FOOTINGS SHALL BE AT OR BELOW INVERT ELEVATIONS OF ELEMENTS
NOTED HEREIN.
7. STEP FOOTINGS AT A RATIO OF ONE (1) VERTICAL TO TWO (2) HORIZONTAL, WITH A MAXIMUM VERTICAL
STEP OF 2'-0", UNLESS NOTED OTHERWISE.
FOUNDATIONS
4. DESIGN PRESSURES FOR WALLS BELOW GRADE:
SOIL WEIGHT ................................................................................................................................................ 120 PCF
AT REST ...................................................................................................................................................... 60 PSF/FT
AT ACTIVE ................................................................................................................................................... 35 PSF/FT
DRAWING NO.
DATES AND REVISIONS
NOTICEAR
CHIT
EC
TS
SREE
NIG
NE
C
®
ONS
T
RU
CT
IO
NM
AN
AG
ERS
THIS ARCHITECTURAL ANDENGINEERING DRAWING IS GIVEN
IN CONFIDENCE. NO USE ORDISSEMINATION MAY BE MADE
WITHOUT PRIOR WRITTENCONSENT OF THE ARCHITECT.
ALL RIGHTS ARE HEREBYSPECIFICALLY RESERVED.
© 2017 RICHARD L. BOWEN + ASSOCIATES, INC.
No. Date / Description
1300
0 S
hake
r B
oule
vard
/ C
leve
land
, Ohi
o 4
4120
Pho
ne:
(216
) 49
1-93
00
Fax
: (21
6) 4
91-8
053
ww
w.r
lba.
com
- e
mai
l@rlb
a.co
m
RIC
HA
RD
L. B
OW
EN
+ A
SS
OC
IAT
ES
INC
.
RLB NO.:
CHECKED BY:
DRAWN BY:
C:\R
evit
Pro
ject
s\88
32 -
Cle
vela
nd M
edic
al M
art_
kcho
w_r
lba_
com
.rvt
10/9
/201
8 4:
08:0
5 P
M
30-A01
GLO
BA
L C
EN
TE
R F
OR
HE
ALT
H IN
NO
VA
TIO
N
8832
1 S
T C
LAIR
AV
EN
UE
NE
, CLE
VE
LAN
D, O
H 4
4114
ST
OR
AG
E B
UIL
DIN
G A
DD
ITIO
N
KKC
KKC
18.10.08 BID AND PERMIT
UR
BA
N F
AR
M
SCALE: 1/8" = 1'-0"30-A01
1 FARM STORAGE SHED PLAN
SCALE: 1/8" = 1'-0"30-A01
2 FARM STORAGE SHED SECTION
SCALE: 1/8" = 1'-0"30-A01
5 FARM STORAGE SHED ELEVATION
MANUFACTURED METAL BUILDING NOTES:
1. PROVIDE 29 GA MIN METAL SIDING WITH 2" MIN RIGID FOAM INSULATION SUPPORTED
BY METAL STUDS AT 16" O.C. MAX.
2. PROVIDE 29 GA MIN METAL ROOF WITH 2" MIN RIGID FOAM INSULATION SUPPORTED
BY METAL STRUCTURE.
3. PROVIDE 12 GA MIN METAL FRAMING.
4. ROOF AND SIDING TO BE SHOP PRIMED AND PAINTED. COLOR TO BE DETERMINED BY
ARCHITECT.
5. PROVIDE MIN 1/2" THICK PRESSURE TREATED OSB INTERIOR WALL FINISH. PRIME
AND PAINT WALLS WITH
6. STORAGE SHED BASIS OF DESIGN: CARPORT CENTRAL (980) 321-9898.
7. METAL BUILDING FABRICATOR TO SUBMIT SHOP DRAWINGS FOR ARCHITECT'S
REVIEW.
8. METAL BUILDING FABRICATOR TO SUBMIT DRAWINGS FOR AHJ REVIEW AS NEEDED.
NOT TO SCALE
PLA
N
NO
RT
HKEY PLAN
METAL INSULATED DOORS AND FRAMES NOTES:
1. DOORS TO BE 72" WIDE X 80" TALL, INSULATED WITH 18GA MIN GALVANIZED FACE
SHEETS WITH INSULATED GLASS HALF LITES.
2. SHOP PRIME AND PAINT BOTH SIDES OF METAL DOORS AND FRAMES TO MATCH
METAL SIDING.
3. DOORS AND FRAMES TO BE BY SAME MANUFACTURER.
4. PROVIDE VERTICAL RODS ON INACTIVE DOORS; PROVIDE MORTISE LOCKSETS WITH
STOREROOM FUNCTION ON ACTIVE DOORS. PROVIDE LOCK CORE AND CYLINDER.
COORDINATE KEYING WITH OWNER.
GUTTER AND DOWNSPOUT NOTES:
1. PROVIDE MIN 2" DOWNSPOUT IN SAME MATERAIL AS GUTTER. PAINT TO MATCH
METAL SIDING. COORDIANTE LOCATION WITH OWNER.
2. PROVIDE STRAPS, ANCHORS, AND OTHER ACCESSORIES NECESSARY FOR GUTTER
AND DOWNSPOUT INSTALLATION.
GENERAL PROJECT NOTES:
1. SUBMIT ALL PRODUCTS FOR ARCHITECT'S REVIEW.
SCALE: 1/16" = 1'-0"30-A01
A SITE PLANSCALE: 1" = 1'-0"30-A01
3 SECTION0 2' 4' 8' 16'
0 3" 6" 1' 2' 0 1' 2' 4' 8'
0 1' 2' 4' 8'
0 1' 2' 4' 8'
Sheets30-A01 - STORAGE BUILDING ADDITION