1
XC14 P.2 XCR XCP XCN 2 30-A01 3' - 0" 10' - 0" 45' - 0" 12' - 0" 9' - 6" 9' - 6" 30-A01 5 6'-0"W X 6'-8"H INSULATED METAL DOORS AND FRAME MANUFACTURED STORAGE BUILDING EXISTING METAL PANEL SYSTEM EXISTING 2'-0" THICK CONCRETE WALL EXISTING 2-HR RATED WALL ASSEMBLY EXISTING 90-MINUTE RATED DOORS TO REMAIN EXIST. CONCRETE PAVING EXIST. GRAVEL DEMO EXISTING CONCRETE PAVING IN HATCHED AREA. EXISTING BOLLARD TO REMAIN, TYPICAL 4" SLAB w/ 6x6~W4xW4 WWF ON 6" COMPACTED FREE DRAINING GRANULAR FILL. B03 - BALLROOM -51' - 2 3/8" B04 - SERVICE PLATFORM -67' - 7 1/4" XC14 1' - 9" 8' - 6" EXISTING 2'-0" THICK CONCRETE WALL MANUFACTURED STORAGE BUILDING EXISTING CURTAIN WALL SYSTEM 6' - 6" 5K, MIN 26 GA, GALVALUME GUTTER, PAINT TO MATCH SIDING 10' - 0" 10' - 3" CONCRETE PAD AND FOOTER 30-A01 3 TYP B04 - SERVICE PLATFORM -67' - 7 1/4" XCP XCN 2 30-A01 PROJECT DESCRIPTION: TO ADD MANUFACTURED SHEDS ON THE B4 LEVEL SITE INFORMATION: PP NO: 101-60- (17,18,19 20, 24,25, 36) 300 LAKESIDE AVE, CLEVELAND, OH 44113 APPLICABLE CODES: 2017 OHIO BUILDING CODE W/2017 UPDATES 2017 NATIONAL ELECTRIC CODE 2017 OHIO FIRE CODE 2012 INTERNATIONAL ENERGY EFFICIENCY CODE CODE SUMMARY: USE CLASSIFICATION SECTION 311 S-1 GENERAL EXISTING BUILDING DATA SECTION 602 TYPE OF CONSTRUCTION 2B BUILDING FIRE RESISTANCE RATINGS FOR EXTERIOR WALLS TABLE 602 FIRE RATING OF EXTERIOR WALL BASED ON SEPARATION DISTANCE X < 5' 2 HOUR FOR S-1 PROJECT AREA STORAGE SHED ADDITION: 450 SF SITE LOCATION MAP N LIFE SAFETY SUMMARY 30-A01 URBAN FARM STORAGE BUILDING ADDITION 30-E01 URBAN FARM STORAGE BUILDING ELECTRICAL PLAN DRAWING INDEX GLOBAL CENTER FOR HEALTH INNOVATION ABOVE STORAGE SHED HUNTINGTON CONVENTION CENTER OF CLEVELAND OCCUPIED AREAS UNEXCAVATED AREA SMG 1 ST CLAIR AVENUE, NE MEZZANINE LEVEL CLEVELAND, OH 44114 STRUCTURAL ENGINEER CLIENT RICHARD L. BOWEN & ASSOCIATES INC. 13000 SHAKER BOULEVARD CLEVELAND, OHIO 44120 216.491.9300 (PH) 216.491.8053 (FX) Contact Person: JEFF GRAHAM ELECTRICAL ENGINEER RICHARD L. BOWEN & ASSOCIATES INC. 13000 SHAKER BOULEVARD CLEVELAND, OHIO 44120 216.491.9300 (PH) 216.491.8053 (FX) Contact Person: JACK MCNEELY BUILDING OWNER CUYAHOGA COUNTY CONVENTION FACILITES DEVELOPMENT CORPORATION 1 ST. CLAIR AVENUE, NE 3RD FLOOR CLEVELAND, OH 44114 RICHARD L. BOWEN & ASSOCIATES INC. 13000 SHAKER BOULEVARD CLEVELAND, OHIO 44120 216.491.9300 (PH) 216.491.8053 (FX) Contact Person: KEN CHOW ARCHITECT PROJECT TEAM 30-A01 1 PROPOSED STORAGE SHED EXISTING CONCRETE WALKWAY TO REMAIN EXISTING BOLLARD TO REMAIN, TYPICAL EXISTING RETAINING WALL AND FENCE TO REMAIN, TYPICAL EXISTING WATER FEATURE EXISTING LIVESTOCK FEEDER/WATERER EXISTING CHICKEN COOP RS WP G 2-#10, 1-#10 GND IN 3/4" C 1 RS-6 WP G 2-#10, 1-#10 GND IN 3/4" C 1 RS-4 2' - 0" 4' - 0" 8" (2)-#5 CONT. TOP & BOT. CONC. SLAB - SEE PLAN PRE-FABRICATED BUILDING WALL, BASE ANGLE AND ATTACHMENT BY PRE-ENGINEERED BUILDING SUPPLIERS #4 2'-0"x2'-0" @ 1'-6" O.C. 4. BUILDING CODE: 2017 OHIO BUILDING CODE (OBC) SITE CLASS ................................................................................................................................................................ D Ss .......................................................................................................................................................................... 0.172 S1 .......................................................................................................................................................................... 0.057 GENERAL 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN, INSTALLATION, AND THE FINAL CLEARANCE OF ANY TEMPORARY NEEDLING, UNDERPINNING, SHORING, OR BRACING OF EXISTING STRUCTURES. 7. CONSTRUCTION LOADS SHALL NOT EXCEED DESIGN LIVE LOADS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DESIGN REQUIRED TO SUPPORT CONSTRUCTION EQUIPMENT USED IN CONSTRUCTING THIS PROJECT. SHORING AND RESHORING IS THE RESPONSIBILITY OF THE CONTRACTOR. 1. COORDINATE WITH ALL DRAWINGS FOR INFORMATION RELATED TO STRUCTURAL WORK. ANY CHANGES TO THE BUILDING STRUCTURAL SYSTEM SHALL BE REDESIGNED ONLY BYRICHARD L. BOWEN + ASSOCIATES, INC. ALL CHANGES MUST HAVE PRIOR AUTHORIZATION OF THE OWNER AND RICHARD L. BOWEN + ASSOCIATES, INC. 2. ALL CONTRACTORS SHALL COORDINATE WITH ALL DRAWINGS WITHIN THE CONTRACT DOCUMENTS. 3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND CONDITIONS RELATED TO EXISTING CONSTRUCTION, EXISTING SERVICES, AND THE SITE BEFORE BEGINNING WORK. 17. ALL WALL FOOTING REINFORCING SHALL RUN CONTINUOUS THROUGH COLUMN FOOTINGS. 18. BEND ALL HORIZONTAL BARS AROUND ADJACENT CORNERS AND LAP ACCORDING TO TABLE #1. 19. BONDBREAKER MATERIAL SHALL BE 15 POUND FELT PAPER. 14. CHAMFER EXPOSED EDGES OF CONCRETE 3/4", UNLESS NOTED OTHERWISE. 15. PROVIDE CONTROL JOINTS IN ALL SLABS ON GRADE AS SHOWN ON DRAWINGS. 5. DESIGN LOADS: SEISMIC DESIGN DATA: OCCUPANCY CATEGORY............................................................................................................................................ I ROOF LIVE LOAD................................................................................................................................................ 20 PSF GROUND SNOW LOAD ............................................................................................................................ Pg=30.0 PSF FLAT ROOF SNOW LOAD .................................................................................................................. Pf=21.0 + DRIFT ROOF SNOW LOAD: FLOOR LIVE LOAD............................................................................................................................................ 100 PSF SEISMIC IMPORTANCE FACTOR ....................................................................................................................... Ie=1.0 SLABS ON GRADE (WELDED WIRE FABRIC).......................................................1/3 SLAB THICKNESS FROM TOP OF SLAB CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH..............................................................................3" LOCATION CLEARANCE TYPICAL REINFORCING BAR CLEARANCE TABLE. WIND DESIGN DATA: MINIMUM LAP SPLICE AND ANCHORAGE DIMENSION TABLE #1 BAR SIZE 1. WHEN LAPPING TWO DIFFERENT SIZE BARS, USE THE LAP DIMENSION OF THE SMALLER BAR OR THE ANCHORAGE DIMENSION OF THE LARGER BAR. USE WHICHEVER DIMENSIONIS LARGER. #5 #4 #6 #3 Fy = GRADE 60, NON-COATED BARS 32" 22" 43" 16" 3000 PSI CONCRETE OTHER BARS 34" 26" 17" 43" 33" 22" 16" 13" TOP BARS 56" 42" 29" #5 #4 #6 #3 21" LAP ANCHORAGE ANCHORAGE LAP BAR SIZE 8. IF THE FABRICATOR HAS BEEN AUTHORIZED TO USE THE ARCHITECT AND ENGINEER'S DRAWINGS AS ERECTION DRAWINGS, THE FABRICATOR MUST REMOVE ALL TITLE BLOCKS, PROFESSIONAL SEALS AND ANY OTHER REFERENCES TO THE ARCHITECT AND ENGINEER FROM THAT ERECTION DRAWING. THE FABRICATOR'S NAME AND TITLE SHALL BE PLACED ON THE ERECTION DRAWINGS. CAST - IN - PLACE CONCRETE 1. CAST IN PLACE CONCRETE SHALL CONFORM TO THE LATEST ACI 318 & 350 CODE, STANDARDS AND ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE", EXCEPT AS MODIFIED HEREIN. 2. SUBMIT LABORATORY TEST REPORTS FOR CONCRETE MATERIALS AND PROPOSED MIX DESIGN TESTS AND DATA. 3. MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE IN 28 DAYS SHALL BE: 3000 PSI - SPREAD FOOTINGS: MINIMUM CEMENT CONTENT OF 470 LB/CUBIC YARD; WC .50 3500 PSI - INTERIOR SLAB: MINIMUM CEMENT CONTENT OF 517 LB/CUBIC YARD; WC .44 4500 PSI - ALL OTHER CONCRETE MINIMUM CEMENT CONTENT OF 564 LB/CUBIC YARD; WC .45 4. REINFORCING BARS: A615 GRADE 60 KSI YIELD STRENGTH, UNLESS NOTED OTHERWISE. WELDING OR TACK WELDING A615 BARS SHALL NOT BE PERMITTED. 5. REINFORCING BARS FOR WELDED APPLICATIONS SHALL CONFORM WITH A706, 60 KSI YIELD STRENGTH. 6. WELDED WIRE FABRIC: ASTM A185, FLAT SHEET. ROLLED WWF SHALL NOT BE PERMITTED. 7. CALCIUM CHLORIDE SHALL NOT BE PERMITTED NOR SHALL ANY ADMIXTURE CONTAINING CALCIUM CHLORIDE BE PERMITTED. 8. ALL CONCRETE SHALL CONTAIN A WATER REDUCING ADMIXTURE CONFORMING TO ASTM C494, TYPE A, F OR G. 9. ALL CONCRETE EXPOSED TO THE WEATHER OR IN A LOCATION VULNERABLE TO DEICERS SHALL CONTAIN AN AIR-ENTRAINED ADMIXTURE CONFORMING TO ASTM C260. THE AMOUNT OF ENTRAINED AIR SHALL BE 6% ± 1%. 10. CONCRETE SHALL BE DISCHARGED AT THE SITE WITHIN 1 1/2 HOURS AFTER WATER HAS BEEN ADDED TO THE CEMENT AND AGGREGATES. ADDITION OF WATER TO THE MIX AT THE PROJECT SITE WILL NOT BE PERMITTED. ALL WATER MUST BE ADDED AT THE BATCH PLANT. SLUMP MAY BE ADJUSTED ONLY THROUGH THE USE OF ADDITIONAL WATER REDUCING ADMIXTURE OR HIGH RANGE WATER REDUCING ADMIXTURE. 11. PRECAST CONCRETE CUBES OR SAND PLATE CHAIRS SHALL BE USED FOR THE SUPPORT OF REINFORCING ON GRADE. CONCRETE BLOCK OR CLAY MASONRY BRICK ARE NOT PERMITTED. 12. CONSTRUCTION JOINTS SHALL BE SUBJECT TO REVIEW BY RICHARD L. BOWEN + ASSOCIATES, INC., AND SHALL BE LOCATED AND DETAILED AS SPECIFIED ON THE DRAWINGS OR AS NOTED. 13. ALL WELDED WIRE FABRIC SHALL BE CHAIRED TO ITS PROPER HEIGHT AND MAINTAINED AT THE PROPER HEIGHT THROUGHOUT THE CONCRETE PLACING OPERATION. LIFTING OF WELDED WIRE FABRIC WITH A HOOK DURING CONCRETE PLACEMENT SHALL NOT BE PERMITTED. 16. TOP LAYER OF REINFORCING STEEL IN FOOTINGS SHALL BE CONSIDERED TO BARS REGARDLESS OF THICKNESS OF CONCRETE BELOW THE BARS. 20. DETERMINE SIZE AND LOCATION OF MECHANICAL EQUIPMENT AND MAKE PROVISIONS FOR BOLTS, SLEEVES, PADS, ETC., IN ACCORDANCE WITH THE MANUFACTURER'S CERTIFIED DRAWINGS. THIS WORK SHALL BE COORDINATED WITH THE TRADES INVOLVED PRIOR TO ANY CONCRETE PLACEMENT. 21. REINFORCING BAR LAP SPLICES AND ANCHORAGE LENGTH SHALL CONFORM WITH "MINIMUM LAP SPLICE AND ANCHORAGE DIMENSION TABLE #1" UNLESS NOTED OTHERWISE ON THE DRAWINGS. BASIC WIND SPEED .............................................................................................................................V = 105 MPH OCCUPANCY CATEGORY.................................................................................................................. CATEGORY I WIND EXPOSURE ................................................................................................................................................... B SNOW LOAD IMPORTANCE FACTOR .............................................................................................................. Is = 0.8 SNOW EXPOSURE FACTOR ........................................................................................................................... Ce = 1.0 SNOW THERMAL FACTOR ............................................................................................................................... Ct = 1.0 1. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE SURVEY BEFORE BEGINNING CONSTRUCTION. 2. DESIGN SOIL BEARING PRESSURE IS 1000 PSF ASSUMED. FROST DEPTH IS 42". 3. SOIL SUITABILITY AND BEARING CAPACITY SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. 5. NOTIFY THE ARCHITECT AS SOON AS POSSIBLE OF ANY UNUSUAL SOIL CONDITIONS. 6. SET FOUNDATIONS AT ELEVATIONS SHOWN, OR ON FIRM MATERIAL OF DESIGN BEARING CAPACITY, WHICHEVER IS LOWER. A. ALL SOIL SURROUNDING AND UNDER ALL FOOTINGS, FLOOR SLABS, ETC. SHALL BE PROTECTED FROM FREEZING AND FROST ACTION DURING CONSTRUCTION. B. WHERE FOOTINGS ARE IN CLOSE PROXIMITY OF SEWERS, DRAINS, CONDUITS, UNDERFLOOR PIPES, ETC., BOTTOM OF ALL FOOTINGS SHALL BE AT OR BELOW INVERT ELEVATIONS OF ELEMENTS NOTED HEREIN. 7. STEP FOOTINGS AT A RATIO OF ONE (1) VERTICAL TO TWO (2) HORIZONTAL, WITH A MAXIMUM VERTICAL STEP OF 2'-0", UNLESS NOTED OTHERWISE. FOUNDATIONS 4. DESIGN PRESSURES FOR WALLS BELOW GRADE: SOIL WEIGHT ................................................................................................................................................ 120 PCF AT REST ...................................................................................................................................................... 60 PSF/FT AT ACTIVE ................................................................................................................................................... 35 PSF/FT DRAWING NO. DATES AND REVISIONS NOTICE A R C H I T E C T S S R E E N I G N E C ® O N S T R U C T I O N M A N A G E R S THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE. NO USE OR DISSEMINATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF THE ARCHITECT. ALL RIGHTS ARE HEREBY SPECIFICALLY RESERVED. © 2017 RICHARD L. BOWEN + ASSOCIATES, INC. No. Date / Description 13000 Shaker Boulevard / Cleveland, Ohio 44120 Phone: (216) 491-9300 Fax: (216) 491-8053 www.rlba.com - [email protected] RICHARD L. BOWEN + ASSOCIATES INC. RLB NO.: CHECKED BY: DRAWN BY: C:\Revit Projects\8832 - Cleveland Medical Mart_kchow_rlba_com.rvt 10/9/2018 4:08:05 PM 30-A01 GLOBAL CENTER FOR HEALTH INNOVATION 8832 1 ST CLAIR AVENUE NE, CLEVELAND, OH 44114 STORAGE BUILDING ADDITION KKC KKC 18.10.08 BID AND PERMIT URBAN FARM SCALE: 1/8" = 1'-0" 30-A01 1 FARM STORAGE SHED PLAN SCALE: 1/8" = 1'-0" 30-A01 2 FARM STORAGE SHED SECTION SCALE: 1/8" = 1'-0" 30-A01 5 FARM STORAGE SHED ELEVATION MANUFACTURED METAL BUILDING NOTES : 1. PROVIDE 29 GA MIN METAL SIDING WITH 2" MIN RIGID FOAM INSULATION SUPPORTED BY METAL STUDS AT 16" O.C. MAX. 2. PROVIDE 29 GA MIN METAL ROOF WITH 2" MIN RIGID FOAM INSULATION SUPPORTED BY METAL STRUCTURE. 3. PROVIDE 12 GA MIN METAL FRAMING. 4. ROOF AND SIDING TO BE SHOP PRIMED AND PAINTED. COLOR TO BE DETERMINED BY ARCHITECT. 5. PROVIDE MIN 1/2" THICK PRESSURE TREATED OSB INTERIOR WALL FINISH. PRIME AND PAINT WALLS WITH 6. STORAGE SHED BASIS OF DESIGN: CARPORT CENTRAL (980) 321-9898. 7. METAL BUILDING FABRICATOR TO SUBMIT SHOP DRAWINGS FOR ARCHITECT'S REVIEW. 8. METAL BUILDING FABRICATOR TO SUBMIT DRAWINGS FOR AHJ REVIEW AS NEEDED. NOT TO SCALE PLAN NORTH KEY PLAN METAL INSULATED DOORS AND FRAMES NOTES : 1. DOORS TO BE 72" WIDE X 80" TALL, INSULATED WITH 18GA MIN GALVANIZED FACE SHEETS WITH INSULATED GLASS HALF LITES. 2. SHOP PRIME AND PAINT BOTH SIDES OF METAL DOORS AND FRAMES TO MATCH METAL SIDING. 3. DOORS AND FRAMES TO BE BY SAME MANUFACTURER. 4. PROVIDE VERTICAL RODS ON INACTIVE DOORS; PROVIDE MORTISE LOCKSETS WITH STOREROOM FUNCTION ON ACTIVE DOORS. PROVIDE LOCK CORE AND CYLINDER. COORDINATE KEYING WITH OWNER. GUTTER AND DOWNSPOUT NOTES : 1. PROVIDE MIN 2" DOWNSPOUT IN SAME MATERAIL AS GUTTER. PAINT TO MATCH METAL SIDING. COORDIANTE LOCATION WITH OWNER. 2. PROVIDE STRAPS, ANCHORS, AND OTHER ACCESSORIES NECESSARY FOR GUTTER AND DOWNSPOUT INSTALLATION. GENERAL PROJECT NOTES : 1. SUBMIT ALL PRODUCTS FOR ARCHITECT'S REVIEW. SCALE: 1/16" = 1'-0" 30-A01 A SITE PLAN SCALE: 1" = 1'-0" 30-A01 3 SECTION 0 2' 4' 8' 16' 0 3" 6" 1' 2' 0 1' 2' 4' 8' 0 1' 2' 4' 8' 0 1' 2' 4' 8'

30-A01 - Huntington Convention Center of Cleveland...4500 PSI - ALL OTHER CONCRETE MINIMUM CEMENT CONTENT OF 564 LB/CUBIC YARD; WC .45 4. REINFORCING BARS: A615 GRADE 60 KSI YIELD

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • XC14

    P.2

    XCR

    XCP

    XCN

    2

    30-A01

    3' - 0" 10' - 0"

    45' -

    0"

    12' -

    0"

    9' -

    6"

    9' -

    6"

    30-A015

    6'-0"W X 6'-8"H

    INSULATED METAL

    DOORS AND FRAME

    MANUFACTURED

    STORAGE BUILDING

    EXISTING METAL

    PANEL SYSTEM

    EXISTING 2'-0" THICK

    CONCRETE WALL

    EXISTING 2-HR RATED

    WALL ASSEMBLY

    EXISTING 90-MINUTE

    RATED DOORS TO

    REMAIN

    EXIST. CONCRETE PAVINGEXIST. GRAVEL

    DEMO EXISTING

    CONCRETE PAVING IN

    HATCHED AREA.

    EXISTING BOLLARD

    TO REMAIN, TYPICAL

    4" SLAB w/ 6x6~W4xW4 WWF

    ON 6" COMPACTED FREE

    DRAINING GRANULAR FILL.

    B03 - BALLROOM-51' - 2 3/8"

    B04 - SERVICE PLATFORM-67' - 7 1/4"

    XC14

    1' -

    9"

    8' -

    6"

    EXISTING 2'-0" THICK

    CONCRETE WALL

    MANUFACTURED STORAGE

    BUILDING

    EXISTING CURTAIN WALL

    SYSTEM

    6' -

    6"

    5K, MIN 26 GA, GALVALUME

    GUTTER, PAINT TO MATCH

    SIDING

    10' - 0"

    10' -

    3"

    CONCRETE PAD AND FOOTER30-A01

    3 TYP

    B04 - SERVICE PLATFORM-67' - 7 1/4"

    XCPXCN

    2

    30-A01

    PROJECT DESCRIPTION:

    TO ADD MANUFACTURED SHEDS ON THE B4 LEVEL

    SITE INFORMATION:

    PP NO: 101-60- (17,18,19 20, 24,25, 36)

    300 LAKESIDE AVE, CLEVELAND, OH 44113

    APPLICABLE CODES:

    2017 OHIO BUILDING CODE W/2017 UPDATES

    2017 NATIONAL ELECTRIC CODE

    2017 OHIO FIRE CODE

    2012 INTERNATIONAL ENERGY EFFICIENCY CODE

    CODE SUMMARY:

    USE CLASSIFICATION

    SECTION 311 S-1

    GENERAL EXISTING BUILDING DATA

    SECTION 602 TYPE OF CONSTRUCTION 2B

    BUILDING FIRE RESISTANCE RATINGS FOR EXTERIOR WALLS

    TABLE 602 FIRE RATING OF EXTERIOR WALL BASED ON SEPARATION DISTANCE

    X < 5' 2 HOUR FOR S-1

    PROJECT AREA

    STORAGE SHED ADDITION: 450 SF

    SITE LOCATION MAPN

    LIFE SAFETY SUMMARY

    30-A01 URBAN FARM STORAGE BUILDING ADDITION

    30-E01 URBAN FARM STORAGE BUILDING ELECTRICAL PLAN

    DRAWING INDEX

    GLOBAL CENTER FOR HEALTH INNOVATION ABOVE

    STORAGE SHED

    HUNTINGTON CONVENTION CENTER OF CLEVELAND

    OCCUPIED AREASUNEXCAVATED AREA

    SMG

    1 ST CLAIR AVENUE, NE

    MEZZANINE LEVEL

    CLEVELAND, OH 44114

    STRUCTURAL ENGINEER

    CLIENT

    RICHARD L. BOWEN & ASSOCIATES INC.

    13000 SHAKER BOULEVARD

    CLEVELAND, OHIO 44120

    216.491.9300 (PH)

    216.491.8053 (FX)

    Contact Person: JEFF GRAHAM

    ELECTRICAL ENGINEERRICHARD L. BOWEN & ASSOCIATES INC.

    13000 SHAKER BOULEVARD

    CLEVELAND, OHIO 44120

    216.491.9300 (PH)

    216.491.8053 (FX)

    Contact Person: JACK MCNEELY

    BUILDING OWNERCUYAHOGA COUNTY CONVENTION FACILITES

    DEVELOPMENT CORPORATION

    1 ST. CLAIR AVENUE, NE

    3RD FLOOR

    CLEVELAND, OH 44114

    RICHARD L. BOWEN & ASSOCIATES INC.

    13000 SHAKER BOULEVARD

    CLEVELAND, OHIO 44120

    216.491.9300 (PH)

    216.491.8053 (FX)

    Contact Person: KEN CHOW

    ARCHITECT

    PROJECT TEAM

    30-A01

    1

    PROPOSED STORAGE SHED

    EXISTING CONCRETE

    WALKWAY TO REMAIN

    EXISTING BOLLARD TO

    REMAIN, TYPICAL

    EXISTING RETAINING WALL

    AND FENCE TO REMAIN,

    TYPICAL

    EXISTING WATER FEATURE

    EXISTING LIVESTOCK

    FEEDER/WATERER

    EXISTING CHICKEN COOP

    RS

    WPG

    2-#10, 1-#10 GND IN 3/4" C

    1

    RS-6

    WPG

    2-#10, 1-#10 GND IN 3/4" C

    1

    RS-4

    2' - 0"4'

    - 0

    "

    8"

    (2)-#5 CONT.

    TOP & BOT.

    CONC. SLAB - SEE PLAN

    PRE-FABRICATED BUILDING WALL,

    BASE ANGLE AND ATTACHMENT BY

    PRE-ENGINEERED BUILDING

    SUPPLIERS

    #4 2'-0"x2'-0" @ 1'-6" O.C.

    4. BUILDING CODE: 2017 OHIO BUILDING CODE (OBC)

    SITE CLASS ................................................................................................................................................................ D

    Ss .......................................................................................................................................................................... 0.172

    S1 .......................................................................................................................................................................... 0.057

    GENERAL

    6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN, INSTALLATION, AND THE FINAL CLEARANCE OF

    ANY TEMPORARY NEEDLING, UNDERPINNING, SHORING, OR BRACING OF EXISTING STRUCTURES.

    7. CONSTRUCTION LOADS SHALL NOT EXCEED DESIGN LIVE LOADS. THE CONTRACTOR SHALL BE

    RESPONSIBLE FOR ALL DESIGN REQUIRED TO SUPPORT CONSTRUCTION EQUIPMENT USED IN

    CONSTRUCTING THIS PROJECT. SHORING AND RESHORING IS THE RESPONSIBILITY OF THE CONTRACTOR.

    1. COORDINATE WITH ALL DRAWINGS FOR INFORMATION RELATED TO STRUCTURAL WORK. ANY CHANGES TO

    THE BUILDING STRUCTURAL SYSTEM SHALL BE REDESIGNED ONLY BYRICHARD L. BOWEN + ASSOCIATES, INC.

    ALL CHANGES MUST HAVE PRIOR AUTHORIZATION OF THE OWNER AND RICHARD L. BOWEN + ASSOCIATES, INC.

    2. ALL CONTRACTORS SHALL COORDINATE WITH ALL DRAWINGS WITHIN THE CONTRACT DOCUMENTS.

    3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND CONDITIONS RELATED TO EXISTING

    CONSTRUCTION, EXISTING SERVICES, AND THE SITE BEFORE BEGINNING WORK.

    17. ALL WALL FOOTING REINFORCING SHALL RUN CONTINUOUS THROUGH COLUMN FOOTINGS.

    18. BEND ALL HORIZONTAL BARS AROUND ADJACENT CORNERS AND LAP ACCORDING TO TABLE #1.

    19. BONDBREAKER MATERIAL SHALL BE 15 POUND FELT PAPER.

    14. CHAMFER EXPOSED EDGES OF CONCRETE 3/4", UNLESS NOTED OTHERWISE.

    15. PROVIDE CONTROL JOINTS IN ALL SLABS ON GRADE AS SHOWN ON DRAWINGS.

    5. DESIGN LOADS:

    SEISMIC DESIGN DATA:

    OCCUPANCY CATEGORY............................................................................................................................................ I

    ROOF LIVE LOAD................................................................................................................................................ 20 PSF

    GROUND SNOW LOAD ............................................................................................................................ Pg=30.0 PSF

    FLAT ROOF SNOW LOAD .................................................................................................................. Pf=21.0 + DRIFT

    ROOF SNOW LOAD:

    FLOOR LIVE LOAD............................................................................................................................................ 100 PSF

    SEISMIC IMPORTANCE FACTOR ....................................................................................................................... Ie=1.0

    SLABS ON GRADE (WELDED WIRE FABRIC).......................................................1/3 SLAB THICKNESS FROM TOP OF SLAB

    CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH..............................................................................3"

    LOCATION CLEARANCE

    TYPICAL REINFORCING BAR CLEARANCE TABLE.

    WIND DESIGN DATA:

    MINIMUM LAP SPLICE AND ANCHORAGE DIMENSION TABLE #1

    BAR SIZE

    1. WHEN LAPPING TWO DIFFERENT SIZE BARS, USE THE LAP DIMENSION OF THE SMALLER BAR OR

    THE ANCHORAGE DIMENSION OF THE LARGER BAR. USE WHICHEVER DIMENSIONIS LARGER.

    #5

    #4

    #6

    #3

    Fy = GRADE 60, NON-COATED BARS

    32"

    22"

    43"

    16"

    3000 PSI CONCRETE

    OTHER BARS

    34"

    26"

    17"

    43"

    33"

    22"

    16" 13"

    TOP BARS

    56"

    42"

    29"

    #5

    #4

    #6

    #3 21"

    LAP ANCHORAGE ANCHORAGELAPBAR SIZE

    8. IF THE FABRICATOR HAS BEEN AUTHORIZED TO USE THE ARCHITECT AND ENGINEER'S DRAWINGS AS

    ERECTION DRAWINGS, THE FABRICATOR MUST REMOVE ALL TITLE BLOCKS, PROFESSIONAL SEALS AND ANY

    OTHER REFERENCES TO THE ARCHITECT AND ENGINEER FROM THAT ERECTION DRAWING. THE

    FABRICATOR'S NAME AND TITLE SHALL BE PLACED ON THE ERECTION DRAWINGS.

    CAST-IN-PLACE CONCRETE

    1. CAST IN PLACE CONCRETE SHALL CONFORM TO THE LATEST ACI 318 & 350 CODE, STANDARDS AND ACI 301

    "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE", EXCEPT AS MODIFIED HEREIN.

    2. SUBMIT LABORATORY TEST REPORTS FOR CONCRETE MATERIALS AND PROPOSED MIX DESIGN TESTS

    AND DATA.

    3. MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE IN 28 DAYS SHALL BE:

    3000 PSI - SPREAD FOOTINGS: MINIMUM CEMENT CONTENT OF 470 LB/CUBIC YARD; WC .50

    3500 PSI - INTERIOR SLAB: MINIMUM CEMENT CONTENT OF 517 LB/CUBIC YARD; WC .44

    4500 PSI - ALL OTHER CONCRETE MINIMUM CEMENT CONTENT OF 564 LB/CUBIC YARD; WC .45

    4. REINFORCING BARS: A615 GRADE 60 KSI YIELD STRENGTH, UNLESS NOTED OTHERWISE. WELDING OR TACK

    WELDING A615 BARS SHALL NOT BE PERMITTED.

    5. REINFORCING BARS FOR WELDED APPLICATIONS SHALL CONFORM WITH A706, 60 KSI YIELD STRENGTH.

    6. WELDED WIRE FABRIC: ASTM A185, FLAT SHEET. ROLLED WWF SHALL NOT BE PERMITTED.

    7. CALCIUM CHLORIDE SHALL NOT BE PERMITTED NOR SHALL ANY ADMIXTURE CONTAINING CALCIUM

    CHLORIDE BE PERMITTED.

    8. ALL CONCRETE SHALL CONTAIN A WATER REDUCING ADMIXTURE CONFORMING TO ASTM C494, TYPE A, F OR G.

    9. ALL CONCRETE EXPOSED TO THE WEATHER OR IN A LOCATION VULNERABLE TO DEICERS SHALL CONTAIN

    AN AIR-ENTRAINED ADMIXTURE CONFORMING TO ASTM C260. THE AMOUNT OF ENTRAINED AIR SHALL BE

    6% ± 1%.

    10. CONCRETE SHALL BE DISCHARGED AT THE SITE WITHIN 1 1/2 HOURS AFTER WATER HAS BEEN ADDED TO

    THE CEMENT AND AGGREGATES. ADDITION OF WATER TO THE MIX AT THE PROJECT SITE WILL NOT BE

    PERMITTED. ALL WATER MUST BE ADDED AT THE BATCH PLANT. SLUMP MAY BE ADJUSTED ONLY THROUGH

    THE USE OF ADDITIONAL WATER REDUCING ADMIXTURE OR HIGH RANGE WATER REDUCING ADMIXTURE.

    11. PRECAST CONCRETE CUBES OR SAND PLATE CHAIRS SHALL BE USED FOR THE SUPPORT OF

    REINFORCING ON GRADE. CONCRETE BLOCK OR CLAY MASONRY BRICK ARE NOT PERMITTED.

    12. CONSTRUCTION JOINTS SHALL BE SUBJECT TO REVIEW BY RICHARD L. BOWEN + ASSOCIATES, INC., AND

    SHALL BE LOCATED AND DETAILED AS SPECIFIED ON THE DRAWINGS OR AS NOTED.

    13. ALL WELDED WIRE FABRIC SHALL BE CHAIRED TO ITS PROPER HEIGHT AND MAINTAINED AT THE PROPER

    HEIGHT THROUGHOUT THE CONCRETE PLACING OPERATION. LIFTING OF WELDED WIRE FABRIC WITH A

    HOOK DURING CONCRETE PLACEMENT SHALL NOT BE PERMITTED.

    16. TOP LAYER OF REINFORCING STEEL IN FOOTINGS SHALL BE CONSIDERED TO BARS REGARDLESS OF

    THICKNESS OF CONCRETE BELOW THE BARS.

    20. DETERMINE SIZE AND LOCATION OF MECHANICAL EQUIPMENT AND MAKE PROVISIONS FOR BOLTS,

    SLEEVES, PADS, ETC., IN ACCORDANCE WITH THE MANUFACTURER'S CERTIFIED DRAWINGS. THIS WORK

    SHALL BE COORDINATED WITH THE TRADES INVOLVED PRIOR TO ANY CONCRETE PLACEMENT.

    21. REINFORCING BAR LAP SPLICES AND ANCHORAGE LENGTH SHALL CONFORM WITH "MINIMUM LAP

    SPLICE AND ANCHORAGE DIMENSION TABLE #1" UNLESS NOTED OTHERWISE ON THE DRAWINGS.

    BASIC WIND SPEED .............................................................................................................................V = 105 MPH

    OCCUPANCY CATEGORY.................................................................................................................. CATEGORY I

    WIND EXPOSURE ................................................................................................................................................... B

    SNOW LOAD IMPORTANCE FACTOR .............................................................................................................. Is = 0.8

    SNOW EXPOSURE FACTOR ........................................................................................................................... Ce = 1.0

    SNOW THERMAL FACTOR ............................................................................................................................... Ct = 1.0

    1. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE SURVEY BEFORE BEGINNING CONSTRUCTION.

    2. DESIGN SOIL BEARING PRESSURE IS 1000 PSF ASSUMED. FROST DEPTH IS 42".

    3. SOIL SUITABILITY AND BEARING CAPACITY SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION.

    5. NOTIFY THE ARCHITECT AS SOON AS POSSIBLE OF ANY UNUSUAL SOIL CONDITIONS.

    6. SET FOUNDATIONS AT ELEVATIONS SHOWN, OR ON FIRM MATERIAL OF DESIGN BEARING CAPACITY,

    WHICHEVER IS LOWER.

    A. ALL SOIL SURROUNDING AND UNDER ALL FOOTINGS, FLOOR SLABS, ETC. SHALL BE PROTECTED

    FROM FREEZING AND FROST ACTION DURING CONSTRUCTION.

    B. WHERE FOOTINGS ARE IN CLOSE PROXIMITY OF SEWERS, DRAINS, CONDUITS, UNDERFLOOR PIPES,

    ETC., BOTTOM OF ALL FOOTINGS SHALL BE AT OR BELOW INVERT ELEVATIONS OF ELEMENTS

    NOTED HEREIN.

    7. STEP FOOTINGS AT A RATIO OF ONE (1) VERTICAL TO TWO (2) HORIZONTAL, WITH A MAXIMUM VERTICAL

    STEP OF 2'-0", UNLESS NOTED OTHERWISE.

    FOUNDATIONS

    4. DESIGN PRESSURES FOR WALLS BELOW GRADE:

    SOIL WEIGHT ................................................................................................................................................ 120 PCF

    AT REST ...................................................................................................................................................... 60 PSF/FT

    AT ACTIVE ................................................................................................................................................... 35 PSF/FT

    DRAWING NO.

    DATES AND REVISIONS

    NOTICEAR

    CHIT

    EC

    TS

    SREE

    NIG

    NE

    C

    ®

    ONS

    T

    RU

    CT

    IO

    NM

    AN

    AG

    ERS

    THIS ARCHITECTURAL ANDENGINEERING DRAWING IS GIVEN

    IN CONFIDENCE. NO USE ORDISSEMINATION MAY BE MADE

    WITHOUT PRIOR WRITTENCONSENT OF THE ARCHITECT.

    ALL RIGHTS ARE HEREBYSPECIFICALLY RESERVED.

    © 2017 RICHARD L. BOWEN + ASSOCIATES, INC.

    No. Date / Description

    1300

    0 S

    hake

    r B

    oule

    vard

    / C

    leve

    land

    , Ohi

    o 4

    4120

    Pho

    ne:

    (216

    ) 49

    1-93

    00

    Fax

    : (21

    6) 4

    91-8

    053

    ww

    w.r

    lba.

    com

    - e

    mai

    l@rlb

    a.co

    m

    RIC

    HA

    RD

    L. B

    OW

    EN

    + A

    SS

    OC

    IAT

    ES

    INC

    .

    RLB NO.:

    CHECKED BY:

    DRAWN BY:

    C:\R

    evit

    Pro

    ject

    s\88

    32 -

    Cle

    vela

    nd M

    edic

    al M

    art_

    kcho

    w_r

    lba_

    com

    .rvt

    10/9

    /201

    8 4:

    08:0

    5 P

    M

    30-A01

    GLO

    BA

    L C

    EN

    TE

    R F

    OR

    HE

    ALT

    H IN

    NO

    VA

    TIO

    N

    8832

    1 S

    T C

    LAIR

    AV

    EN

    UE

    NE

    , CLE

    VE

    LAN

    D, O

    H 4

    4114

    ST

    OR

    AG

    E B

    UIL

    DIN

    G A

    DD

    ITIO

    N

    KKC

    KKC

    18.10.08 BID AND PERMIT

    UR

    BA

    N F

    AR

    M

    SCALE: 1/8" = 1'-0"30-A01

    1 FARM STORAGE SHED PLAN

    SCALE: 1/8" = 1'-0"30-A01

    2 FARM STORAGE SHED SECTION

    SCALE: 1/8" = 1'-0"30-A01

    5 FARM STORAGE SHED ELEVATION

    MANUFACTURED METAL BUILDING NOTES:

    1. PROVIDE 29 GA MIN METAL SIDING WITH 2" MIN RIGID FOAM INSULATION SUPPORTED

    BY METAL STUDS AT 16" O.C. MAX.

    2. PROVIDE 29 GA MIN METAL ROOF WITH 2" MIN RIGID FOAM INSULATION SUPPORTED

    BY METAL STRUCTURE.

    3. PROVIDE 12 GA MIN METAL FRAMING.

    4. ROOF AND SIDING TO BE SHOP PRIMED AND PAINTED. COLOR TO BE DETERMINED BY

    ARCHITECT.

    5. PROVIDE MIN 1/2" THICK PRESSURE TREATED OSB INTERIOR WALL FINISH. PRIME

    AND PAINT WALLS WITH

    6. STORAGE SHED BASIS OF DESIGN: CARPORT CENTRAL (980) 321-9898.

    7. METAL BUILDING FABRICATOR TO SUBMIT SHOP DRAWINGS FOR ARCHITECT'S

    REVIEW.

    8. METAL BUILDING FABRICATOR TO SUBMIT DRAWINGS FOR AHJ REVIEW AS NEEDED.

    NOT TO SCALE

    PLA

    N

    NO

    RT

    HKEY PLAN

    METAL INSULATED DOORS AND FRAMES NOTES:

    1. DOORS TO BE 72" WIDE X 80" TALL, INSULATED WITH 18GA MIN GALVANIZED FACE

    SHEETS WITH INSULATED GLASS HALF LITES.

    2. SHOP PRIME AND PAINT BOTH SIDES OF METAL DOORS AND FRAMES TO MATCH

    METAL SIDING.

    3. DOORS AND FRAMES TO BE BY SAME MANUFACTURER.

    4. PROVIDE VERTICAL RODS ON INACTIVE DOORS; PROVIDE MORTISE LOCKSETS WITH

    STOREROOM FUNCTION ON ACTIVE DOORS. PROVIDE LOCK CORE AND CYLINDER.

    COORDINATE KEYING WITH OWNER.

    GUTTER AND DOWNSPOUT NOTES:

    1. PROVIDE MIN 2" DOWNSPOUT IN SAME MATERAIL AS GUTTER. PAINT TO MATCH

    METAL SIDING. COORDIANTE LOCATION WITH OWNER.

    2. PROVIDE STRAPS, ANCHORS, AND OTHER ACCESSORIES NECESSARY FOR GUTTER

    AND DOWNSPOUT INSTALLATION.

    GENERAL PROJECT NOTES:

    1. SUBMIT ALL PRODUCTS FOR ARCHITECT'S REVIEW.

    SCALE: 1/16" = 1'-0"30-A01

    A SITE PLANSCALE: 1" = 1'-0"30-A01

    3 SECTION0 2' 4' 8' 16'

    0 3" 6" 1' 2' 0 1' 2' 4' 8'

    0 1' 2' 4' 8'

    0 1' 2' 4' 8'

    Sheets30-A01 - STORAGE BUILDING ADDITION