LZR - I30 /S600 PARAMETERS

A - NO

P - NC

A - NOP - NC P - NC

A - NOP - NCA - NO

R1

R2

A = activeP = passive

NO = normally openNC = normally closed

OUTPUT CONF IGURAT ION

MINIMUM OBJECT S IZE

The distances between the curtains depends on the mounting height and side.When mounted on the left, the distance between curtain C1 and curtain C4 is approximately 4 in. for every 3 ft (mounting height).EXAMPLE: At 15 ft. mounting height, the distance between C1 and C4 is 20 in.

LZR T IPS

T H E L Z R - I 3 0 R E Q U I R E S 1 0 - 3 5 V C L E A N D C P O W E R

( N O N - R E C T I F I E D )

A F T E R 3 0 M I N U T E S , T H E S E N S O R L O C K S A C C E S S T O

T H E R E M O T E C O N T R O L S E S S I O N . P O W E R C Y C L E T H E

S E N S O R T O R E C O N F I G U R E .

A BEA UNIVERSAL REMOTE IS REQUIRED TO

CONF IGURE THE LZR - I30 .

UN IVERSAL REMOTE CONTROL T IPS

T O Q U E S T I O N A PA R A M E T E R , P R E S S

A F T E R U N L O C K I N G A N D C H O O S I N G A

PA R A M E T E R . C O U N T T H E L E D F L A S H E S .

C O N S I D E R U S I N G A N A C C E S S C O D E

TO SET AN ACCESS CODE:

TO DELETE AN ACCESS CODE:

V I RT U A L P U S H P L AT E :

FA C T O RY D E FA U LT S :

A LWAY S F I N I S H A N A D J U S T M E N T S E S S I O N

B Y L A U N C H I N G A S E T U P :

T O T U R N T H E L E D s O N / O F F :

F O R V I S I B L E L A S E R B E A M S :

T O C H A N G E O R Q U E S T I O N A PA R A M E T E R ,

S TA RT B Y P R E S S I N G T H E A N D F I N I S H

T H E S E S S I O N B Y P R E S S I N G

# OF ACT IVE DETECT ION CURTAINS

Increase in case of snow, dead leaves, etc.

UNCOVERED ZONE

2 i n 4 i n 6 i n 8 i n 10 i n

MOUNTING S IDE

left right left center

WITH BACKGROUND WITHOUT BACKGROUND

right

indoor outdoorlow

outdoormed

outdoorhigh

Choose between environment or object.

IMMUNITY F I LTER

FOR CRITICAL ENVIRONMENTS(RAIN, SNOW, FOG)

indoor outdoorlow

outdoormed

outdoorhigh

FOR CRITICAL OBJECTS(BLACK CARS)

O F F 3 i n 4 i n 6 i n 8 i n

OUTPUT ACT IVAT ION DELAY

O F F 100ms 200ms 300ms 400ms 500ms 600ms 700ms 800ms 900ms

The relays are triggered when the detection duration ≥ the selected time.

CURTAIN C1 C2 C3 C4

CURTAIN IS INACTIVE ON BOTH FIELDS

CURTAIN IS ACTIVE ON OPTIONAL FIELD

CURTAIN IS ACTIVE ON SAFETY FIELD

CURTAIN IS ACTIVE ON BOTH FIELDS

C1 + C2 ARE ACTIVE ON SAFETY FIELDC3 + C4 ARE ACTIVE ON OPTIONAL FIELD

C1 IS ACTIVE ON BOTH FIELDSC2 + C3 ARE ACTIVE ON SAFETY FIELDC4 IS INACTIVE

ALL CURTAINS ARE ACTIVE ON BOTH FIELDS

EXAMPLE CONF IGURAT IONS

OPT IONAL F IELD WIDTH

OPT IONAL F IELD HE IGHT

SAFETY F IELD WIDTH

SAFETY F IELD HE IGHT

UNIVERSAL REMOTE CONTROL | FALCON & IS40 SER IES

79.0216.01 20150217

M ICROWAVE PARAMETERS

INFRARED PARAMETERS

LEARN T IME EXPLANAT ION

UNIVERSAL REMOTE CONTROL T IPS

T O Q U E S T I O N A PA R A M E T E R , P R E S S

A F T E R U N L O C K I N G A N D C H O O S I N G A

PA R A M E T E R . C O U N T T H E L E D F L A S H E S .

C O N S I D E R U S I N G A N A C C E S S C O D E

TO SET AN ACCESS CODE:

TO DELETE AN ACCESS CODE:

R E L AY C O N F I G U R AT I O N :

FA C T O RY D E FA U LT S :

A LWAY S F I N I S H A N A D J U S T M E N T S E S S I O N

B Y L A U N C H I N G A S E T U P :

T O C H A N G E O R Q U E S T I O N A PA R A M E T E R ,

S TA RT B Y P R E S S I N G T H E A N D F I N I S H

T H E S E S S I O N B Y P R E S S I N G

1-4

low

SENS IT IV ITY

XXS XS S > > > > XL XXL

0.5s 1s 2s 3s 4s 5s 6s 8s 9s7s

ACT IVAT ION RELAY HOLD T IME

bi uni unidepart

bi = two-way detectionuni = one-way detection towards sensoruni depart = one-way detection away from sensor

DETECT ION MODE

1 2 3 4 5 6

REJECT ION MODE

1: DETECTION OF ALL KINDS OF TARGETS IN MOTION2: DETECTION OF ALL KINDS OF TARGETS IN MOTION + INTERFERENCE IMMUNITY3: LOW ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY4: MEDIUM ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY5: HIGH ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY6: HIGHEST ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY

NOTES FACTORY DEFAULTS

DOOR DOOR DOOR DOORDOOR1 2 3 4 5

DOOR DOOR DOOR DOOR6 7 8 9

IR PATTERN S IZE

FREQUENCY

IR IMMUNITY

AUTOMATIC LEARN T IME

low

high

medium high

30s 1 min 2 min 5 min 10 min 20 min 1 h 1.5 h 2 h

I R TARGET S IZE

DOOR

3x3

DOOR

4x4

DOOR

3x2

DOOR

1x2 1x1

2x2

IF AN OBJECT IS IN THE PRESENCE DETECTION FIELD AND REMAINS MOTIONLESS FOR LONGER THAN THE PROGRAMMED LEARN TIME, THE SENSOR WILL ACCEPT THE OBJECT AS PART OF ITS BACKGROUND/REFERENCE POINT AND WILL DROP THE DETECTION SIGNAL.

**INFINITY ( ∞ ) WILL NEVER LEARN A NEW BACKGROUND**∞

L