1
^ _ ^ _ ^ _ ^ _ ^ _ ^ _ ^ _ STA. 110 STA. 115 STA. 120 STA. 125 STA. 130 STA. 135 STA. 140 STA. 145 STA. 150 STA. 155 STA. 160 STA. 165 STA. 167 STA. 170 STA. 175 STA. 180 STA. 185 STA. 190 STA. 195 STA. 200 STA. 205 STA. 505 STA. 240 STA. 515 STA. 517 STA. 520 STA. 535 STA. 207 STA. 105 STA. 100 STA. 90 STA. 83 ATLANTA CHARLOTTE RICHMOND PHILADELPHIA NEW YORK CITY WASHINGTON DC BALTIMORE ATLANTIC SUNRISE EXPANSION PROJECT TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC. APRIL 16, 2014 GAS PIPELINE ^ _ ^ _ ^ _ STA. 520 STA. 517 STA. 515 STA. 505 STA. 205 STA. 200 STA. 195 STA. 190 STA. 185 WASHINGTON DC BALTIMORE PHILADELPHIA YORK TIOGA PIKE BERKS LYCOMING KENT WAYNE SULLIVAN LUZERNE CLINTON BUCKS CENTRE BRADFORD PERRY LANCASTER CHESTER ADAMS POTTER MONROE SUSSEX SCHUYLKILL BURLINGTON DAUPHIN CECIL MORRIS SUSSEX FREDERICK ATLANTIC BALTIMORE UNION SULLIVAN CARROLL SUSQUEHANNA LEHIGH CARBON HARFORD ORANGE WYOMING SNYDER LEBANON MIFFLIN SALEM JUNIATA COLUMBIA FAIRFAX WARREN CUMBERLAND CUMBERLAND NEW CASTLE HUNTERDON MONTGOMERY LACKAWANNA MONTGOMERY CAROLINE SOMERSET TALBOT HOWARD MERCER CAMDEN ULSTER NORTHAMPTON GLOUCESTER PRINCE GEORGES NORTHUMBERLAND CAPE MAY QUEEN ANNES DELAWARE JEFFERSON MONTOUR PRINCE WILLIAM PHILADELPHIA UNION CLARKE DELAWARE BALTIMORE CITY WASHINGTON FULTON QUEEN ANNES ESSEX CULPEPER PROPOSED PIPELINES PROPOSED REPLACEMENTS EXISTING TRANSCO PIPELINE " ) EXISTING TRANSCO COMPRESSOR STATION MARCELLUS SHALE BASIN : 0 80 160 40 Miles FIGURE 1.1-2 REV. 3 (PO XXXX) 5 1 7 6 1 1 2 1 4 3 PROPOSED PRELIMINARY PROJECT SCOPE ATLANTIC SUNRISE EXPANSION PROJECT (Case 5D8-1) 1) 2) 3) 4) 5) 42" Central Penn Line South 30" Central Penn Line North 36" E Line GRUGAN LOOP 42" D Line UNITY LOOP 30" A & B Lines VIRGINIA Replacement 122.19 56.35 5.45 9.00 2.52 LENGTH IN MILES PIPELINE FACILITIES/MODIFICATIONS 6) STA 605 - Construct a Greenfield compressor station around MP 53.9 7) STA 610 - Construct a Greenfield compressor station around MP 100.5 8) Receipt meter station at Owego 9) STA 520 - Add 1 ea. Solar Mars 100S (16,000 ISO HP ea.) 10) STA 520 - Replace compressor #6 & 7 internal wheels and Modify Compressor #8 aero assemblies to accomodate new flow parameters 11) STA 517 - Add 1 ea. Solar Mars 100S (16,000 ISO HP ea.) with 3 bays of cooling and one scrubber 12) Receipt meter station at Zick 13) Interconnect at springville pipeline crossing 14) Regular station at Transco tie-in MP L92.7 15) Tie-in at 515L40 at MP L113.75 (West Diamond) 16) Regular station at Transco tie-in MP L113.75 (West Diamond) 17) Regular station at Transco MP 1682.65 (River Road) with tie-in to three mainlines and ODEC lateral 18) STA 190 - Modify valves and yard piping for southflow compression 19) STA 190 - Add 1 X 25,000HP electric compressor unit 20) STA 185 - Modify valves and yard piping for southflow compression 21) STA 170 - Modify valves and yard piping for southflow compression 22) STA 160 - Modify valves, yard piping and regulation for southflow compression 23) STA 150 - Modify valves and yard piping for southflow compression, re-located Iredell lateral backpressure regulator 24) STA 145 - Modify valves and yard piping for southflow compression 25) Supplemental Odorization from Station 140 to Station 160 i. Odor masking / de-odorization of valves at valve sites for venting 11 valve sites ii. Odor masking / de-odorization of valves at 4 compressor stations (145, 150, 155, 160) iii. Odor Detection and supplemental odorization at 41 meter stations FOR DISCUSSION PURPOSES ONLY SUBJECT TO CHANGE 1 5 18 1 7 6 2 1 4 3 9 9 11 20 12 18 20 25 21 22 23 24 25 25 25 11 BI-D I R EC T I ON AL GA S FL OW BI- D IR EC TI O N A L GAS F LO W B I-D IR E CT I ON AL G AS F L O W 10 14 8 15 16 17 13 12 19 8 13 14 15 16 17 19 10 25 G:\101769\16.0 GIS\Project Location Map\Northern Market Area 032814.mxd

Williams Transco Atlantic Sunrise Project Map

Embed Size (px)

DESCRIPTION

A map of the proposed nearly $3 billion upgrade to the Transco natural gas pipeline that will, for the first time in 50 years, change the direction gas flows along the pipeline. The change will allow Williams to flow cheap, abundant Marcellus Shale gas to the south and southwest. The change will make the pipeline bidirectional and includes building new pipeline and upgrading compressor stations. Williams is currently in the pre-filing stage with the Federal Energy Regulatory Commission.

Citation preview

Page 1: Williams Transco Atlantic Sunrise Project Map

STA. 110

STA. 115STA. 120

STA. 125

STA. 130

STA. 135 STA. 140

STA. 145STA. 150

STA. 155

STA. 160

STA. 165 STA. 167STA. 170

STA. 175STA. 180

STA. 185

STA. 190

STA. 195

STA. 200 STA. 205STA. 505

STA. 240

STA. 515STA. 517STA. 520

STA. 535

STA. 207

STA. 105

STA. 100

STA. 90STA. 85

STA. 83

STA. 80

ATLANTA

CHARLOTTE

RICHMOND

PHILADELPHIA

NEW YORK CITY

WASHINGTON DC BALTIMORE

ATLANTIC SUNRISE EXPANSION PROJECTTRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC.

APRIL 16, 2014 GAS PIPELINE

STA. 520STA. 517 STA. 515

STA. 505

STA. 205STA. 200

STA. 195

STA. 190

STA. 185 WASHINGTON DC

BALTIMORE

PHILADELPHIA

YORK

TIOGA

PIKE

BERKS

LYCOMING

KENT

WAYNE SULLIVAN

LUZERNECLINTON

BUCKS

CENTRE

BRADFORD

PERRY

LANCASTERCHESTER

ADAMS

POTTER

MONROE SUSSEX

SCHUYLKILL

BURLINGTON

DAUPHIN

CECIL

MORRIS

SUSSEX

FREDERICK ATLANTICBALTIMORE

UNION

SULLIVAN

CARROLL

SUSQUEHANNA

LEHIGH

CARBON

HARFORD

ORANGEWYOMING

SNYDER

LEBANON

MIFFLIN

SALEM

JUNIATA

COLUMBIA

FAIRFAX

WARREN

CUMBERLAND

CUMBERLANDNEW CASTLE

HUNTERDON

MONTGOMERY

LACKAWANNA

MONTGOMERY

CAROLINE

SOMERSET

TALBOT

HOWARD

MERCER

CAMDEN

ULSTER

NORTHAMPTON

GLOUCESTER

PRINCE GEORGES

NORTHUMBERLAND

CAPE MAYQUEEN ANNES

DELAWARE

JEFFERSON

MONTOUR

PRINCE WILLIAM

PHILADELPHIA

UNION

CLARKE

DELAWARE

BALTIMORE CITY

WASHINGTON

FULTON

QUEEN ANNES

ESSEX

CULPEPER

PROPOSED PIPELINESPROPOSED REPLACEMENTSEXISTING TRANSCO PIPELINE

") EXISTING TRANSCO COMPRESSOR STATIONMARCELLUS SHALE BASIN

:0 80 16040Miles

FIGURE 1.1-2 REV. 3 (PO XXXX)

5

17

6

11

2143

PROPOSED PRELIMINARY PROJECT SCOPEATLANTIC SUNRISE EXPANSION PROJECT (Case 5D8-1)

1)2)3)4)5)

42" Central Penn Line South 30" Central Penn Line North 36" E Line GRUGAN LOOP 42" D Line UNITY LOOP 30" A & B Lines VIRGINIA Replacement

122.1956.355.459.002.52

LENGTH IN MILESPIPELINE

FACILITIES/MODIFICATIONS 6) STA 605 - Construct a Greenfield compressor station around MP 53.97) STA 610 - Construct a Greenfield compressor station around MP 100.58) Receipt meter station at Owego9) STA 520 - Add 1 ea. Solar Mars 100S (16,000 ISO HP ea.) 10) STA 520 - Replace compressor #6 & 7 internal wheels and Modify Compressor #8 aero assemblies to accomodate new flow parameters11) STA 517 - Add 1 ea. Solar Mars 100S (16,000 ISO HP ea.) with 3 bays of cooling and one scrubber12) Receipt meter station at Zick13) Interconnect at springville pipeline crossing14) Regular station at Transco tie-in MP L92.715) Tie-in at 515L40 at MP L113.75 (West Diamond)16) Regular station at Transco tie-in MP L113.75 (West Diamond)17) Regular station at Transco MP 1682.65 (River Road) with tie-in to three mainlines and ODEC lateral18) STA 190 - Modify valves and yard piping for southflow compression19) STA 190 - Add 1 X 25,000HP electric compressor unit20) STA 185 - Modify valves and yard piping for southflow compression21) STA 170 - Modify valves and yard piping for southflow compression22) STA 160 - Modify valves, yard piping and regulation for southflow compression23) STA 150 - Modify valves and yard piping for southflow compression, re-located Iredell lateral backpressure regulator24) STA 145 - Modify valves and yard piping for southflow compression25) Supplemental Odorization from Station 140 to Station 160 i. Odor masking / de-odorization of valves at valve sites for venting 11 valve sites ii. Odor masking / de-odorization of valves at 4 compressor stations (145, 150, 155, 160) iii. Odor Detection and supplemental odorization at 41 meter stations

FOR DISCUSSION PURPOSES ONLY SUBJECT TO CHANGE

11

5

18

17

6

2143

99

11

20

12

1820

25

21

22

23

24

25

2525

11

BI-DIRECTIONAL GAS FLOW

BI-DIRECTIONAL GAS FLOW

BI-DIR

ECTIO

NALG

ASFL

OW

10

14

8

1516

17

13

12

19

813

141516

17

19

10

25