6
Control Yoke Reconnection of EMBRAER 170 Eng.Ramez Enwesri (B1) Libya Petro Air Co.

Control yoke reconnection

Embed Size (px)

Citation preview

Page 1: Control yoke reconnection

Control Yoke Reconnection

of

EMBRAER 170

Eng.Ramez Enwesri (B1)

Libya – Petro Air Co.

Page 2: Control yoke reconnection

The Task

Task 27-11-12-840-801-A gives all steps and procedure to carry out the Control Yoke Disconnect Device – Reconnection.

In this presentation we will focus on some points which might be help, where we carried out this task few days ago.

But you have to obey the task.

Eng.Ramez Enwesri (B1) - Libya

Page 3: Control yoke reconnection

The Practices Note

You do not need to remove any parts to reach the Disconnect Device. The Area is clear to set the tools.

It will be good to use a Multimeter with long terminal leads, to be far enough to hear the sound, as result of Close Circuit between pins A & B.

You have to know that the Reconnect Wrench jaws movement should be out of each other.

When you hear the sound of the Multimeter, do not stop. Wait for seconds, and turn the Reconnect Wrench for more 2 or 3 turns. You will feel a strong reaction, then stop.

Eng.Ramez Enwesri (B1) - Libya

Page 4: Control yoke reconnection

Jaws movement

Floating Plate Movement Eng.Ramez Enwesri (B1) - Libya

Page 5: Control yoke reconnection
Page 6: Control yoke reconnection

Ramez Ramadan Enwesri

Eng. B1

Libya – Petro Air Co.

Email: [email protected]

Mobile: +218 91 324 6152