38
Interior Maintenance Company, Inc. Jon Barrett- Business Development Specialist Phone: 267-886-7903 Email: [email protected] Specialists in Industrial and Commercial Cleaning services including Combustible Dust, High Surface, HVAC Air Duct System, Dust Collector, and Lab Fume Hood System cleaning, serving the United States. Copyright 2010 Interior Maintenance Company, Inc. www.imc.cc

Imc comdust presentation revised 092310

Embed Size (px)

Citation preview

Page 1: Imc comdust presentation revised 092310

Interior Maintenance Company, Inc.Jon Barrett- Business Development Specialist

Phone: 267-886-7903 Email: [email protected]

Specialists in Industrial and Commercial Cleaning services including Combustible Dust, High Surface,

HVAC Air Duct System, Dust Collector, and Lab Fume Hood System cleaning, serving the United States.

Copyright 2010 Interior Maintenance Company, Inc. www.imc.cc

Page 2: Imc comdust presentation revised 092310

CSB Combustible Dust Safety Video

WWW.IMC.CC

Page 3: Imc comdust presentation revised 092310

Got Dust?

www.imc.cc

Significant accumulation of particulate dust at the ceiling of production facility.

Page 4: Imc comdust presentation revised 092310

Fresh footprints

WWW.IMC.CC

PVC Resin Dust- 2 feet Deep in some Areas!

Page 5: Imc comdust presentation revised 092310

PVC Resin Dust-several inches thick on Overhead Beams!

WWW.IMC.CC

Page 6: Imc comdust presentation revised 092310

Show Me The Dust!

www.imc.ccSignificant accumulation of dust within an HVAC duct system.

Page 7: Imc comdust presentation revised 092310

Treat All Dust as if they are Combustible Dust, Unless Tested!

• Have a Sampling of Dust Tested, for Kst Value!

Page 8: Imc comdust presentation revised 092310

Combustible Dust KST Value Chart

When looking to protect your equipment against a dust explosion, it is critical that you know the

Kst value of your material. Kst, is the dust deflagration index, and it measures the relative

explosion severity compared to other dusts. This is a relative index, however, and any material

with a Kst value greater than zero is considered to be at risk of an explosion. In fact, sugar has a

relatively low Kst value, but was the fuel for for a massive explosion in 2008 that claimed the lives

of 14 workers1.

Examples of Kst Values for Different Types of Dusts2

Dust explosion

class* Kst (bar.m/s)* Characteristic* Typical material**

St 0 0 No explosion Silica

St 1 >0 and ? 200 Weak explosion Powdered milk, charcoal, sulfur, sugar

and zinc

St 2 >200 and ?

300 Strong explosion

Cellulose, wood flour, and poly methyl

acrylate

St 3 >300 Very strong

explosion

Anthraquinone, aluminum, and

magnesium

The actual class is sample specific and will depend on varying characteristics of the material such

as particle size or moisture.

* OSHA CPL 03-00-008 - Combustible Dust National Emphasis Program.

** NFPA 68, Standard on Explosion Prevention by Deflagration Venting.

Page 9: Imc comdust presentation revised 092310

IMC Technicians Performing High Surface cleaning of Dust

WWW.IMC.CC

Page 10: Imc comdust presentation revised 092310

HEPA Vacuuming Combustible Aluminum/Titanium Dust on Ceiling Beam

www.imc.cc

Page 11: Imc comdust presentation revised 092310

Initial Combustible Dust Hazards

• Manufacturing facilities need to Test/Evaluate Combustible Dust/Particulate, in all areas with the presence of dust. MSDS do not address the Combustible Dust Hazard.

• Most manufacturing facility's Housekeeping or Custodial staff are not typically trained, nor equipped for safe cleaning procedures, proper containment, recycling, and disposal of Combustible Dust/Particulate.

www.imc.cc

Page 12: Imc comdust presentation revised 092310

HEPA Vacuuming Combustible Aluminum/Titanium Dust on Vertical Wall Surface

www.imc.cc

Page 13: Imc comdust presentation revised 092310

Facility Awareness• Combustible Dust must be contained at

the source.

• A simple spark from a Forklift contacting a concrete floor, could set off an explosion.

• Static Electricity may also set off an explosion.

• Electrical systems need to be evaluated.

www.imc.cc

Page 14: Imc comdust presentation revised 092310

IMC Technicians Performing High Surface cleaning of Dust

www.imc.cc

Page 15: Imc comdust presentation revised 092310

Contain The Source!

www.imc.cc

Accumulation of dust particulate buildup inside a filter chamber of an HVAC system.

Page 16: Imc comdust presentation revised 092310

Why 1/32 of an Inch of Dust?• Any amount of Dust accumulation, on any surface

or piece of equipment, acts as an insulator.• This added insulation of dust may cause

manufacturing, electronics and other equipment to heat up and breakdown.

• Added insulation of dust may also cause Electric and Utility costs to increase and may cause Fire Suppression Systems to fail. Is that a high Return On your Investment?

• Insurance Companies require a clean facility and equipment to keep rates down and to ensure decreased liability from hazards.

www.imc.cc

Page 17: Imc comdust presentation revised 092310

Dust Collectors• Dust Collectors- designed to capture dust and

particulate at the source.• So why so much dust?

1) Broken or Leaking seals/gaskets

2) Clogged ductwork/piping

3) Filters and bags are clogged, torn, undersized, or “missing”

4) Not enough CFM pull, from exhaust fans

5) Preventative Maintenance Program/ Housekeeping is non-existent

www.imc.cc

Page 18: Imc comdust presentation revised 092310

Diagram of Dust Collector

www.imc.cc

Page 19: Imc comdust presentation revised 092310

Dust Collectors

www.imc.cc

Page 20: Imc comdust presentation revised 092310

Aluminum Dust in Exhaust System

WWW.IMC.CC

Page 21: Imc comdust presentation revised 092310

HVAC Systems

• HVAC Air Conveyance Systems- designed to filter and deliver conditioned air.

• So why so much dust in HVAC Systems?

1) Dust Collector and other production equipment emitting heavy concentrations of dust and particulate into the air.

2) Clogged ductwork/piping

3) Filters are clogged, undersized, not installed properly, torn or “missing”

4) Not enough CFM pull, from exhaust fans

5) Preventative Maintenance Program/ Housekeeping is non-existent

www.imc.cc

Page 22: Imc comdust presentation revised 092310

Diagram of HVAC System

www.imc.cc

Page 23: Imc comdust presentation revised 092310

HVAC System

www.imc.cc

Page 24: Imc comdust presentation revised 092310

HVAC Rooftop Unit and Ductwork

www.imc.cc

Page 25: Imc comdust presentation revised 092310

Paper Dust in Recycling Center Office Area

Ceiling Tile

Batt Insulation

WWW.IMC.CC

Page 26: Imc comdust presentation revised 092310

Paper Dust-Above Office Space Areas

Ductwork

WWW.IMC.CC

Page 27: Imc comdust presentation revised 092310

Lab Fume Hoods• Lab Fume Hoods- designed to remove carbon,

smoke, particulate, and vapors from lab workspaces.

• Why decreased draw or decreased face velocity?

1) Dust Collector emitting heavy concentrations of dust and particulate into the air2) Clogged Fume Hood, ductwork/piping 3) Filters are clogged, undersized, or “missing” 4) Not enough CFM pull, from exhaust fans5) Preventative Maintenance Program/ Housekeeping is non-existent

www.imc.cc

Page 28: Imc comdust presentation revised 092310

Diagram of Lab Fume Hood

www.imc.cc

Page 29: Imc comdust presentation revised 092310

Lab Fume Hood

www.imc.cc

Page 30: Imc comdust presentation revised 092310

Heat Exchanger• Heat Exchanger and Portable heaters- designed to heat

air in designated work area space.

• Why so much dust on heat exchanger or not enough heat?

1) Dust Collector emitting heavy concentrations of dust and particulate into the air2) Airborne Dust in high concentrations3) Improper installation of Heat Exchanger (too close to ceiling, or another surface4) Preventative Maintenance Program/ Housekeeping is non-existent

www.imc.cc

Page 31: Imc comdust presentation revised 092310

Heat Exchanger

www.imc.cc

Page 32: Imc comdust presentation revised 092310

Health Concerns and Indoor Air Quality, with Any Dust

• Lungs and heart- become congested, decreased blood flow to body. Many types of diseases and disabilities to occur, (Silicosis, Black Lung), short term and long term exposure, increase in Sick Days

• Eyes- unsafe working conditions, may lead to accidents, increase in Sick Days

• Fatigue- workers may decrease productivity, may lead to an accident, increase in Sick Days

• Insurance- Increase in Workmen’s Compensation, Short term and Long term disability, Increase in Liability insurance

• PPE- Increase use of proper PPE, may decrease sick days

www.imc.cc

Page 33: Imc comdust presentation revised 092310

HEPA Vacuuming Combustible Aluminum/Titanium Dust on Horizontal Beam

www.imc.cc

Page 34: Imc comdust presentation revised 092310

Maintenance Issues With Dust

• Lighting is decreased

• More Electric or Power is required, as a result - Utilities are increased

• Decreased safety awareness, lower employee morale

www.imc.cc

Page 35: Imc comdust presentation revised 092310

Combustible Dust Cleaning Per NFPA 654

• Prevent ANY Dust Clouds!

• Do NOT use Compressed Air!

• Do NOT Broom Sweep!

• Use Certified, Tested, HEPA Explosion Proof Vacuums!

• Foam Cleaning can be used, for Certain Dusts/Areas- (But NOT to be used for ANY Metal Dusts!)

www.imc.cc

Page 36: Imc comdust presentation revised 092310

Treat All Dust as if they are Combustible Dust, Unless Tested!

• Have a Sampling of Dust Tested, for Kst Value!

www.imc.cc

Page 37: Imc comdust presentation revised 092310

Clean Up the Dust, and Go Home Safely!

www.imc.cc

Page 38: Imc comdust presentation revised 092310

About IMC

Please contact IMC to provide a free estimate regarding any of your combustible dust

cleaning needs.Jon Barrett can be reached at

(267) 886-7903 or Email: [email protected] is N.F.P.A. and Fire Protection Research

Foundation trained for Explosive DustCleaning, and Chilworth Technology trained for

Dust Explosion Inspection and Cleaning.

Thank you for your time and consideration!

www.imc.cc