2
Electricity Supply Act 1997 (Act 447) P.U.(A)38/94 Electricity Regulations 1994 Regulation 15 Apparatus, conductor, accessory or apparatus that is exposed to weather, water, corrosion, undue heating or use in inflammable surroundings or in an explosive atmosphere shall be constructed or protected in such a manner as to prevent danger. Regulation 16 Switch, switch fuse, fuse switch, circuit breaker, contractor, fuse or circuit breaker shall be constructed and arranged in such a manner so as to break the current when it exceeds a given value for such a sufficient time to prevent danger or overheating, arcing or from the scattering of hot metal or other substances or enclose. Project 1 Application of Building Services Elaine Bong Poh Hui // 0310432 Electrical Supply System Stormwater Drainage System Laws of Malaysia Act 133, Street Drainage and Building Act 1947 Regulation 54 Cleansing and emptying surface and storm water drains, etc. (2) The local authority may, with the sanction of the State Authority, cause all or any of such surface and storm water drains, culverts, gutters and water-courses to communicate with and be emptied into the sea or other fit place, or may cause the refuse from the same to be conveyed by a proper channel to the most convenient site for its deposit, and may sell or otherwise dispose of the said refuse for any agricultural or other purposes as are deemed expedient so that it shall not become a nuisance. Regulation 56 Rain-water pipes not to be used as soil pipes (1) No pipe used for the carrying off of rain water from any roof shall be used for the purpose of carrying off the soil or drainage from any privy or water-closet or any sullage water. Ground Floor Plan // NTS First Floor Plan // NTS Electric Meter Distribution Board LED 24W Downlight Switch 13A Switch Socket Outlet Kitchen Chandelier LED Wall Light Ceiling Fan Air Conditioner Gutter and Downpipe Roof Plan // NTS

Building service board

Embed Size (px)

Citation preview

Page 1: Building service board

Electricity Supply Act 1997 (Act 447) P.U.(A)38/94 Electricity Regulations 1994

Regulation 15Apparatus, conductor, accessory or apparatus that is exposed to weather, water, corrosion,

undue heating or use in inflammable surroundings or in an explosive atmosphere shall be constructed or protected in such a manner as to prevent danger.

Regulation 16Switch, switch fuse, fuse switch, circuit breaker, contractor, fuse or circuit breaker shall be

constructed and arranged in such a manner so as to break the current when it exceeds a given value for such a sufficient time to prevent danger or overheating, arcing or from the

scattering of hot metal or other substances or enclose.

Project 1 Application of Building Services Elaine Bong Poh Hui //

0310432

Electrical Supply System

Stormwater Drainage SystemLaws of Malaysia Act 133, Street Drainage and Building Act 1947

Regulation 54 Cleansing and emptying surface and storm water drains, etc.(2) The local authority may, with the sanction of the State Authority, cause all or any of such surface and storm water drains, culverts, gutters and water-courses to communicate with and

be emptied into the sea or other fit place, or may cause the refuse from the same to be conveyed by a proper channel to the most convenient site for its deposit, and may sell or otherwise dispose of the said refuse for any agricultural or other purposes as are deemed

expedient so that it shall not become a nuisance.

Regulation 56 Rain-water pipes not to be used as soil pipes(1) No pipe used for the carrying off of rain water from any roof shall be used for the purpose

of carrying off the soil or drainage from any privy or water-closet or any sullage water.

Ground Floor Plan // NTS

First Floor Plan // NTS

Electric Meter Distribution Board LED 24W Downlight Switch 13A Switch

Socket Outlet

Kitchen Chandelier LED Wall Light Ceiling Fan Air Conditioner

Gutter and DownpipeRoof Plan // NTS

Page 2: Building service board

Sewage and Sanitary System Laws of Malaysia Act 133, Street Drainage and Building /act 1947(1) No water-pipe, stack-pipe or down spout used for conveying surface water from any

premises shall be used or be permitted to serve or to act as a ventilating shaft to any drain or sewer.

ReasoningThe installation and the design of the sanitary place is safe, so that the disposal waste could

be directed out of the building safely, without threatening the health of occupants.

Cold Water and Hot Water Supply SystemUBBL BY-LAW

84. Suitable measures should be taken to prevent penetration of dampness and moisture into the building.

89. A chase made in wall for pipes and other services facilities shall leave the wall at the back of the chase, not less than 100mm thick in external wall and not less than 100mm

thick in party wall and shall not be wider than 200mm.123. (2) The access openings to ducts or enclosures shall be long enough and suitably

placed to enable lengths of pipe to be installed and removed.

Project 1 Application of Building Services Elaine Bong Poh Hui //

0310432

Vent Pipe Gully PipeManhole Cover S Trap

Ground Floor Plan // NTS

Floor Trap

Ground Floor Plan // NTS

Cold Water Tank

Hot Water Tank

Water Meter Stop Cock Gate Valve Ball Valve Cold Water and Hot Water Supply System Schematic Diagram

Sewage and Sanitary Schematic Diagram

Referencechina-ogpe.com,. (2014). Gate Valve. Retrieved from http://www.china-ogpe.com/catalog/19/gate_valve_214_16.htmlCitrad,. (2014). LED 24W Downlight. Retrieved from http://www.citrad.com/wp-content/uploads/2014/04/LED-24W-

Downlight1.jpgFocus Technology Co., Ltd.,. (2014). Socket Outlet. Retrieved from http://image.made-in-

china.com/2f0j00ISPTGLeCgEkn/13A-Switched-Socket-Outlet-S86K1Z3F-S86K2Z3F-.jpgGil-Lec Electrical Wholesalers Ltd.,. (2014). Switch. Retrieved from

http://lgcdn.gillec.co.uk/media/catalog/product/cache/1/image/9df78eab33525d08d6e5fb8d2 7136e95/m/k/mk-logic-architrave-switch-1gang-k4841whi.jpgPerbadanan Putrajaya,. (2014). Uniform Building By-Laws 1984. Malaysia: MDC Publishers Sdn Bhd.Plumb 24/7,. (2014). What is subsoil drainage? - Professional Plumbing Services. Professional Plumbing Services.

Retrieved 27 November 2014, from http://www.plumb247.co.za/what-is-subsoil-drainage/Stein, B., Reynolds, J., & McGuinness, W. (1992). Mechanical and electrical equipment for buildings. New York: J. Wiley

& Sons.