ELIS PLZEŇ a. s. ELIS PLZEŇ a. s.
PRODUCTSPRODUCTS
ULTRASONIC WATER ULTRASONIC WATER ANDAND FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic1
ULTRASONIC FLOW METERSULTRASONIC FLOW METERS
• Intended for measurement of conductive and non- conductive clean liquids as water, demineralized water, fuel, oil, etc.
• Principal: transit time (measurement of time of flying ultrasonic beam from one to second transductor in direction of flow and in opposite direction of flow).
• The flow rate is calculated from difference of time.
• Flow meters are produced in single and dual beam version.
• They don’t have any moving parts
• They have min. pressure loses
2ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
• Produced categories of ultrasonic flow meters:Produced categories of ultrasonic flow meters:
• Battery supplied single or dual beam:Battery supplied single or dual beam:
• FLOMIC FL5024, FL5044 (DN32 to DN200)(DN32 to DN200)
• FLOMIC FL5034, FL5054 (DN32 to DN300)(DN32 to DN300)
• FLOMIC FL3085 (DN200 to DN1200)(DN200 to DN1200)
• FLOMIC FL3005 (DN200 to DN2000) for direct(DN200 to DN2000) for direct assembly into pipingassembly into piping
3
ULTRASONIC FLOW METERSULTRASONIC FLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
• Main powered single or dual beam:Main powered single or dual beam:
• SONOELIS SE404X, SE406X (DN32 to DN300)(DN32 to DN300)
• SONOELIS SE401X, SE402X (DN200 to DN1200)(DN200 to DN1200)
• SONOELIS SE804X, SE806X (DN200 to DN1200)(DN200 to DN1200)for direct assembly in to pipingfor direct assembly in to piping
4
ULTRASONIC FLOW METERSULTRASONIC FLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5024 (single beam)FLOMIC FL5044 (dual beam)
5
BATTERY POWERED BATTERY POWERED ULTRASONIC WATERULTRASONIC WATER METERS METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5024 (single beam)FLOMIC FL5044 (dual beam)
• Certified according to MID (European metrology certificate) and OIML R49
• Designed in observance of standard EN14154
• Intended for measurement of clean water and substitution Intended for measurement of clean water and substitution ofof mechanical water meters WOmechanical water meters WOLLTMAN typeTMAN type
• Intended for diagnostic of general condition of water network Intended for diagnostic of general condition of water network and water leakages in pipingand water leakages in piping
• They can measure instantaneous flow rate in both direction, They can measure instantaneous flow rate in both direction, consumption of water, pressureconsumption of water, pressure
• They don’t have any moving partsThey don’t have any moving parts• They have very low pressure loses They have very low pressure loses
6
BATTERY POWERED BATTERY POWERED ULTRASONIC WATERULTRASONIC WATER METERS METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5024 (single beam), FLOMIC FL5044 (dual beam)
• Nominal diameter: DN32 to DN200 (single beam), DN65 to DN200 (dual beam)
Technical parametersFLOMIC FL5024
FLOMIC FL5044
Nominal diameter 32 40 50 65 80 100 125 150 200
Overload flow [m3/hr] 12,5 20 31,25 50 78,75 125 200 312,5 500
Permanent flow [m3/hr] 10 16 25 40 63 100 160 250 400
Transition flow [m3/hr] 0,32 0,512 0,8 1,28 2,016 3,2 5,12 8,0 12,8
0,64 1,0 1,6 2,5 4,0 6,4
Min. flow [m3/hr] 0,2 0,32 0,5 0,8 1,26 2,0 3,2 5,0 8,0
0,4 0,63 1,0 1,6 2,5 4,0
Pulse number [liters/pulse]
10 10 25 50 50 100 100 100 250
7
BATTERY POWERED BATTERY POWERED ULTRASONIC WATERULTRASONIC WATER METERS METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5024 (single beam)FLOMIC FL5044 (dual beam)
• Material of sensor: casting from cast iron• Connection: flanges (EN, ANSI, JIS)• Water pressure class: MAP16• Temperature class: T50• Flow-profile sensitivity class: U5 (FL5044), U10 (FL5024) – in
front of meter D3 (FL5044), D5 (FL5024) – behind meter• Pressure loss class: ∆P10• Climatic and mechanical class: B• Electromagnetic environment: E1, E2• Display unit: single-line 8 character LC display• Flow rate sampling period: 1 sec• Protection class: IP68
8
BATTERY POWERED BATTERY POWERED ULTRASONIC WATERULTRASONIC WATER METERS METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5024 (single beam)FLOMIC FL5044 (dual beam)
• Power supply: Li battery 3,6 V/19Ah – live time 8 years
• Output: passive pulse output (U= 3 to 30V, I = 0,002 to 10mA, timp = 30ms)passive current output 4 to 20mA(U = 10 to 24 V)
• Optional equipment: bi-directional measurement (± passive pulse output)passive current output 4 to 20mA in
combination of electrical contact for flow directionUSB, RS232 or RS232 + USB converterGSM module FLODAT FD1.00
9
BATTERY POWERED BATTERY POWERED ULTRASONIC WATERULTRASONIC WATER METERS METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5024 (single beam)FLOMIC FL5044 (dual beam)
• BASIC DIMENSIONS and WEIGHT
Diameter 32 40 50 65 80 100 125 150 200
L [mm] 260 300 300 300 350 350 350 350 350
S [mm] 140 145 150 155 160 165 180 190 205
Weight [kg] 4,5 7 10 11 15 17,5 22,5 26 36,5
10
BATTERY POWERED BATTERY POWERED ULTRASONIC WATERULTRASONIC WATER METERS METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5034 (single beam)FLOMIC FL5054 (dual beam)
11
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5034 (single beam)FLOMIC FL5054 (dual beam)
• Intended for measurement of clean water• They can measure instantaneous flow rate in both direction,
consumption of water, pressure• They don’t have any moving parts• They have very low pressure loses
12
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5034 (single beam), FLOMIC FL5054 (dual beam)
• Nominal diameter: DN32 to DN300 (single beam), DN40 to DN300 (dual beam)
Technical parameters
FL5034
FL5054
Nominal diameter
32 40 50 65 80 100 125 150 200 250 300
Overload flow [m3/hr]
20 31,25 50 78,75 125 200 250 312,5 500 787,5 1250
Permanent flow [m3/hr]
16 25 40 63 100 160 200 250 400 630 1000
Transition flow [m3/hr]
0,4 0,635 1,02 1,6 2,52 4,0 5,0 6,3 12,8 20,1 32,0
0,32 0,51 0,8 1,28 2,05 2,56 3,2 6,4 10,08 16,0
Min. flow [m3/hr]
0,25 0,397 0,635 1,0 1,587 2,54 3,17 3,97 8,0 12,6 20,0
0,2 0,32 0,5 0,8 1,28 1,6 2,0 4,0 6,3 10,0
Pulse number [liters/pulse]
10 10 25 50 50 100 100 100 250 250 500
13
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5034 (single beam)FLOMIC FL5054 (dual beam)
• Material of sensor: weldment (measuring part is made from ss-steel 1.4403, flanges and cover from
carbon steel)• Connection: flanges (EN, ANSI, JIS)• Water pressure class: MAP16, MAP40• Temperature class: T50• Flow-profile sensitivity class: U5 (FL5044), U10 (FL5024) – in
front of meterD3 (FL5044), D5 (FL5024) – behind meter
• Pressure loss class: ∆P10• Climatic and mechanical class: B• Electromagnetic environment: E1, E2• Display unit: single-line 8 character LC display
14
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5034 (single beam)FLOMIC FL5054 (dual beam)
• Flow rate sampling period: 1 sec• Power supply: Li battery 3,6 V/19Ah – live time 8 years • Protection class: IP68• Output: passive pulse output (U= 3 to 30V, I = 0,002 to 10mA,
timp = 30ms)passive current output 4 to 20mA (U = 10 to 24V)
• Optional equipment: complete ss-sensorbi-directional measurement (± passive pulse output)passive current output 4 to 20mA in combinationof electrical contact for flow directionUSB, RS232 or RS232 + USB converterGSM module FLODAT FD1.00
15
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL5034 (single beam)FLOMIC FL5054 (dual beam) • BASIC DIMENSIONS and WEIGHT
Diameter 32 40 50 65 80 100 125 150 200 250 300
L [mm] 360 360 360 360 360 360 360 360 450 450 450
S [mm] 175 180 185 190 200 210 225 235 255 280 305
Weight [kg] 1,6 MPa 18 19 20 29 46 59
Weight [kg] 4,0 MPa 10 10 12 13 16 18 21 22 38 71 85
16
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL3085 (single beam)
17
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL3085 (single beam)
• Intended for measurement of clean water in big dimensions• Measurement of instantaneous flow rate in both direction
and consumption of water• Storage data• They don’t have any moving parts• They have very low pressure loses
18
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL3085 (single beam)
• Nominal diameter: DN200 to DN1200 • Material of sensor: weldment, material from carbon
steel, painted• Connection: flanges (EN, ANSI, JIS)• Nominal pressure: PN6, PN10, PN16, PN40• Temperature of liquid: 0 to 150°C• Ultrasonic transductors: 2 pcs of US2.1 (manufactured by
ELIS PLZEŇ a. s.)• Display unit: single-line 8 character LC display• Power supply: Li-battery + 2 x Alkali batteries 9V,
live time 4 years• Transductors connection cable: max. 20m• Accuracy: ±1% in range 1:20
19
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL3085 (single beam)
• Flow rate sampling period: 1 sec• Protection class: of electronic: IP65• Protection of sensor: IP54/IP68• Outputs: passive pulse output (U= 30V,
I = 10mA)passive current output 4
to 20mA (U = 24V)
• Optional equipment: complete ss-sensorbi-directional measurement (± passive
pulse output)passive current output 4 to 20mA in
combination of electrical contact for flow direction
USB, RS232 or RS232 + USB converter
20
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL3085 (single beam)
21
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL3005 (single beam)
22
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL3005 (single beam)
23
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL3005 (single beam)
• Intended for measurement of clean water on big piping • Installation directly to existing piping• Measurement of instantaneous flow rate in both direction
and consumption of water• Theoretical calibration after installation• Storage data
24
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL3005 (single beam)
• Nominal diameter: DN200 to DN2000 • Nominal pressure: PN40• Temperature of liquid: 0 to 150°C• Ultrasonic transductors: 2 pcs of US2.1 (manufactured
by ELIS PLZEN a. s.)• Display unit: single-line 8 character LC display• Flow rate sampling period: 1 sec• Power supply: Li-battery + 2 x Alkali batteries 9V,
live time 4 years• Transductors connection cable: max. 20m• Protection class of electronic: IP65• Protection of sensor: IP54/IP68
25
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
FLOMIC FL3005 (single beam)
• Output: passive pulse output (U= 3 to 30V, I = 10mA) passive current output 4 to 20mA, (U = 24V)
communication interface RS232• Accuracy: ± 2% in range 1:20• Optional equipment: bi-directional measurement (± passive
pulse output)passive current output 4 to 20mA in
combination of electrical contact for flow direction
USB, RS232 or RS232 + USB converter
26
BATTERY POWERED BATTERY POWERED ULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE404X (single beam)SONOELIS SE406X (dual beam)
27
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE404X (single beam)SONOELIS SE406X (dual beam)
• Intended for measurement of non conductive and conductive clean liquids as water, demineralized water, condensate, fuel, diesel, oil
• Measurement of instantaneous flow rate in both direction and consumption of water
• Measurement of mass flow and mass of water with connection of temperature sensor Pt100
• They don’t have any moving parts• They have very low pressure loses
28
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE404X (single beam)SONOELIS SE406X (dual beam)
• Nominal diameter: DN32 to DN300• Nominal pressure: PN16, PN40• Measurement accuracy: ±1% for velocity of liquid v>0,5 m/s (SE404X)• ±0,5% for velocity of liquid v>0,5 m/s (SE406X)• Temperature of liquid: 0 to 150°C• Ambient temperature: +5 to +55°C• Display unit: alpha-numerical LCD unit, 2 lines,
16 characters each• Power supply: 90 to 230V AC, 50 to 60Hz• Protection class: electronics IP65, sensor IP67
29
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE404X (single beam)SONOELIS SE406X (dual beam)
• Material of sensor: weldment (measuring part is made from ss-steel 1.4301, flanges and cover from carbon steel)
• Flow-profile sensitivity class: U5 (SE406X), U10 (SE404X) – in front of meterD3 (SE406X), D5 (SE404X) – behind meter
• Outputs: pulse output (selected 0.1 to 1,000 l/pulse)Frequency output, selected 0 t 1,000 Hz or 10kHzRelay type 24V AC/0,1A
30
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE404X (single beam)SONOELIS SE406X (dual beam)
• Optional equipment: communication line RS485extended temperature range for sensors: - 20° to 180°CCurrent output (0)4 to 20mAMass-flow rate measurement capabilityFlow rate measurement in two directionssensor protection class IP68100 m (max.) transductors connection cable
31
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE404X (single beam)SONOELIS SE406X (dual beam)
• METER VERSION, CONFIGURATION and TYPE DESIGNATION
VERSION COMPACT REMOTE
CONFIGURATION Economic Standard Comfort Economic Standard Comfort
SINGLE-BEAM SENSOR
SE4040 SE4042 SE4044 SE4041 SE4043 SE4045
DUAL-BEAM SENSOR
SE4060 SE4062 SE4064 SE4061 SE4063 SE4065
32
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE404X (single beam)SONOELIS SE406X (dual beam)
33
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
34
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE401X (single beam)SONOELIS SE402X (dual beam)
• Intended for measurement of non conductive and conductive clean liquids as water, demineralized water
• Measurement of instantaneous flow rate in both direction and consumption of water
• Measurement of mass flow and mass of water with connection of temperature sensor Pt100
• They don’t have any moving parts• They have very low pressure loses
35
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE401X (single beam)SONOELIS SE402X (dual beam)
• Nominal diameter: DN200 to DN1200• Nominal pressure: PN16, PN40• Measurement accuracy: ±1% for velocity of liquid v>0,5 m/s (SE401X)• ±0,5% for velocity of liquid v>0,5 m/s (SE402X)• Temperature of liquid: 0 to 150°C• Ambient temperature: +5 to +55°C• Display unit: alpha-numerical LCD unit, 2 lines,
16 characters each• Power supply: 90 to 230V AC, 50 to 60Hz• Protection class: electronics IP65, sensor IP54
36
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE401X (single beam)SONOELIS SE402X (dual beam)
• Material of sensor: weldment (material of measuring part flanges from carbon steel)
• Flow-profile sensitivity class: U5 (SE402X), U10 (SE401X) – in front of meter
D3 (SE402X), D5 (SE401X) – behind meter• Outputs: pulse output (selected 0.1 to 1,000 l/pulse)
Frequency output, selected 0 t 1,000 Hz or 10kHzRelay type 24VAC/0,1A
37
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE401X (single beam)SONOELIS SE402X (dual beam)
• Optional equipment: communication line RS485extended temperature range for sensors:
- 20° to 180°CCurrent output (0)4 to 20mAMass-flow rate measurement capabilityFlow rate measurement in two directionssensor protection class IP68100 m (max.) transductors connection
cable
38
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE401X (single beam)SONOELIS SE402X (dual beam)
• METER VERSION, CONFIGURATION and TYPE DESIGNATION
VERSION REMOTE
CONFIGURATION ECONOMIC STANDARD
COMFORT
SINGLE-BEAM SENSOR SE4011 SE4013 SE4015
DUAL-BEAM SENSOR SE4021 SE4023 SE4025
39
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE401X (single beam)SONOELIS SE402X (dual beam)
40
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
41
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE804X (single beam)SONOELIS SE806X (dual beam)
42
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE804X (single beam)SONOELIS SE806X (dual beam)
• Intended for measurement of clean water on big piping • Installation directly to existing piping• Measurement of instantaneous flow rate in both direction
and consumption of water• Measurement of mass flow and mass of water with connection
of temperature sensor Pt100• Theoretical calibration after installation
43
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE804X (single beam)SONOELIS SE806X (dual beam)
• Nominal diameter: DN200 to DN1200 • Nominal pressure: PN40• Temperature of liquid: 0° to 150°C• Ultrasonic transductors: 2 pcs of US2.1 (manufactured
by ELIS PLZEŇ a. s.)• Display unit: single-line 8 character LC display• Power supply: 90 to 250VAC, 50 to 60Hz• Transductors connection cable: max. 100m• Protection class of electronic: IP65• Protection of sensor: IP54
44
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
SONOELIS SE804X (single beam)SONOELIS SE806X (dual beam)
• Output: passive pulse output (U= 3 to 30V, I = 10mA)passive current output 4 to 20mA, (U =
24V)communication interface RS232
• Accuracy: ± 2% in range 1:20• Optional equipment: communication line RS485
extended temperature range for sensors-20° to 180°CCurrent output (0) 4 to 20mAMass-flow rate measurement capabilityFlow rate measurement in two directionssensor protection class IP68100 m (max.) transductors connection
cable
45
MAIN POWEREDMAIN POWEREDULTRASONIC ULTRASONIC FLOW METERSFLOW METERS
ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic
ELIS PLZEŇ a. s.ELIS PLZEŇ a. s.
Luční 15Luční 15
301 64 Plzeň301 64 Plzeň
Czech RepublicCzech Republic
PhonePhone: : +420 +420 377 517 751377 517 751
Fax: Fax: +420 +420 377 517 722377 517 722
E-mail: E-mail: [email protected]
http://www.elis.cz
46
Thank you for your attentionThank you for your attention