    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 1 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    LABORATORY LOCATION: (PERMANENT LABORATORY)

    METCAL TECHNOLOGIES (M) SDN. BHD. NO. 36, CANGKAT BUKIT BELAH 11920 BAYAN LEPAS PULAU PINANG MALAYSIA

    FIELDS OF CALIBRATION: DIMENSIONAL, MASS, FORCE, TORQUE, TEMPERATURE, PRESSURE, VOLUME, ELECRTRICAL, TIME AND FREQUENCY

    This laboratory has demonstrated its technical competence to operate in accordance with MS ISO/IEC 17025:2017 (ISO/IEC 17025:2017). This laboratory’s fulfillment of the requirements of ISO/IEC 17025 means the laboratory meets both the technical competence requirements and management system requirements that are necessary for it to consistently deliver technically valid test results and calibrations. The management system requirements in ISO/IEC 17025 are written in language relevant to laboratory operations and operate generally in accordance with the principles of ISO 9001 (see Joint ISO-ILAC-IAF Communiqué dated April 2017). * The expanded uncertainties are based on an estimated confidence probability of approximately 95% and have a coverage factor of k=2 unless stated otherwise.

    SCOPE OF CALIBRATION: DIMENSIONAL

    SITE: CATEGORY I

    Instrument Calibrated/

    Measurement Parameter

    Calibration and Measurement

    Capability Expressed as an Uncertainty(±)*

    Range Remarks

    Coordinate Measuring Machine

    X-axis : 0 to 1500 mm Y-axis : 0 to 1500 mm Z-axis : 0 to 1500 mm

    Diagonal : 0 to 1500 mm

    (0.4 + 13 L) µm

    ‘L’ in metre

    Long Gauge Block, Ball Bar based on ISO 10360-2:2010 and 10360-5:2010

    Profile Projector X, Y-axis: 3 µm Comparison with

    (Measuring Accuracy 0 to 300 mm standard scale

    of Individual Axis) based on

    JIS B 7184:1999

    Measuring Scope X, Y-axis: 2 µm Comparison with

    (Measuring Accuracy 0 to 300 mm standard scale

    of Individual Axis) based on

    JIS 7153:1995

    Surface Plate 600 x 600 mm 1.3 µm Planekator,

    1200 x 1200 mm 1.5 µm micro-indicator

    1800 x 1800 mm 1.7 µm based on

    JIS B 7513:1992

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 2 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: DIMENSIONAL

    SITE: CATEGORY I

    Signatories:

    1. Kenny Ching Ah Hoo ( except CMM ) 2. Eunice Wong Phaik Gaik ( except CMM ) 3. Ching Kar Chien 4. Chew Siou Lian ( except CMM )

    Instrument Calibrated /

    Measurement Parameter

    Range

    Calibration and Measurement

    Capability Expressed as an Uncertainty(±)*

    Remarks

    Vernier, Dial & Digital Height Gauge / Linear Height

    0 mm to 600 mm

    (1.3 + 4.7L) µm

    ‘L’ in metre

    Comparison with gauge blocks,

    length comparator height master

    riser blocks based on

    JIS B 7517:2018

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 3 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: DIMENSIONAL

    Signatories:

    1. Kenny Ching Ah Hoo 2. Eunice Wong Phaik Gaik 3. Ching Kar Chien 4. Chew Siou Lian

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement

    Capability Expressed as an Uncertainty(±)*

    Remarks

    Gauge Block 0.5 mm to 100 mm (0.11 + 3L) µm

    ‘L’ in metre

    Comparison with master gauge block based on ISO 3650 /

    JIS B 7506:2004

    High Accuracy 0 mm to 25 mm 0.4 µm Comparison with gauge block

    based on JIS B 7502:2016

    Micrometer (0.0001 mm res.)

    External Micrometer 0 mm to 25 mm 0.8 µm

    25 mm to 100 mm 0.8 µm

    100 mm to 250 mm 2.3 µm

    250 mm to 500 mm

    4.7 µm

    Vernier, Dial & Digital 0 mm to 600 mm (6.4 + 3.4L) µm Comparison with

    Caliper caliper checker /

    ‘L’ in metre gauge block based

    on JIS B 7507:2016

    Dial Gauge / 0 mm to 50 mm 1.7 µm Comparison with

    Digital Indicator gauge tester based

    on JIS B 7503:2017

    Dial Test Indicator 0 mm to 1.6 mm 1.6 µm Comparison with

    gauge tester based

    on JIS B 7533:2015

    Vernier, Dial & Digital Height Gauge

    0 mm to 100 mm 100 mm to 600 mm

    (0.6 + 2.8L) µm (9.3L) µm

    ‘L’ in metre

    Comparison with caliper checker /

    gauge block based on JIS B 7517:2018

    Dial & Digital Thickness Gauge

    0 to 20 mm 2.5 µm Comparison with gauge block based on JIS B 7503:2017

    Plain Pin Gauge (diameter only)

    0.10 mm to 25 mm 0.58 µm Direct measurement with micrometer based on

    JIS B 7420:1997

    Feeler Gauge 0.01 mm to 3 mm 0.78 µm Direct measurement with micrometer based

    on JIS B 7524:2008

    Depth Micrometer/Gauge

    0 mm to 300 mm 6 µm Comparison with gauge block based on JIS B 7544:1994 /

    JIS B 7518:1993

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 4 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: DIMENSIONAL

    Signatories:

    1. Ching Kar Chien 2. Chew Siou Lian

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Plain Ring Gauge 20 mm to 100 mm (0.4 µm + 12L) µm Length

    Comparator

    ‘L’ in metre JIS B 7420:1997

    Glass Scale 0 mm to 200 mm 6.2 µm Measuring

    System and

    Reference

    Scale on

    JIS B 7541:2001

    Steel Ruler 0 mm to 300 mm 0.068 mm Measuring

    Projector

    JIS B 7516:2005

    Angle Protractor 0 Degree to 60 Degree 0.13 Degree Sine Bar, Slip

    Gauges,

    Comparator

    VDI/WDE/DGQ

    2618

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 5 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: DIMENSIONAL

    Instrument Calibrated/ Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Height Master Up to 300 mm 2.3 µm Comparison with

    gauge block

    based on

    AS 3779:1990

    Riser Block Up to 300 mm 2.3 µm Comparison with

    gauge block

    based on

    AS 3779:1990

    Electrical Comparator ± 5 µm 0.10 µm Comparison with

    (Mu-checker) ± 15 µm 0.16 µm gauge block

    ± 50 µm 0.31 µm based on

    ± 150 µm 1.2 µm JIS B 7536:1982

    ± 500 µm 2.9 µm

    ± 1500 µm 12 µm

    Parallel Thread Plug Major diameter 0.6 µm Three wire

    Gauge 1 mm to 25 mm method

    based on

    Pitch diameter 1.7 µm JIS B 0261:2004

    0.25 mm to 6 mm

    Pitch 3.4 µm

    0.25mm to 3 mm

    Signatories:

    1. Eunice Wong Phaik Gaik (Except for Scope Parallel Thread Plug Gauge) 2. Ching Kar Chien 3. Chew Siou Lian

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 6 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: MASS SITE: CATEGORY I

    Instrument Calibrated/ Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Weighing Balance Up to 50 g 0.039 mg Standard weight based on

    ASTM E898-88:2013

    (Analytical Balance, Up to 250 g 0.27 mg

    Scale, Electronic type, Up to 5000 g 0.019 g

    platform or pallet) Up to 10 kg 0.65 g

    Up to 20 kg 2.6 g

    Up to 150 kg 0.049 kg

    Up to 300 kg 0.067 kg

    Up to 500 kg 0.12 kg

    Up to 1000 kg 0.45 kg

    Up to 3000 kg 1.6 kg

    Standard Weight 1 kg 2 kg 5 kg 10 kg 20 kg

    13 mg 19 mg 40 mg 77 mg 0.16 g

    Direct Comparison using the ABBA or

    AB1…. BnA weighing sequence

    Signatories:

    1. Kenny Ching Ah Hoo ( except Standard Weight ) 2. Eunice Wong Phaik Gaik ( except Standard Weight ) 3. Ching Kar Chien 4. Chew Chii Tsong

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 7 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: MASS

    Instrument Calibrated/ Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Standard Weights 1 mg 0.009 mg Direct Comparison

    using the ABBA or AB1 …BnA

    weighing sequence.

    2 mg 0.009 mg

    5 mg 0.009 mg

    10 mg 0.009 mg

    20 mg 0.010 mg

    50 mg 0.010 mg

    100 mg 0.010 mg

    200 mg 0.011 mg

    500 mg 0.011 mg

    1 g 0.012 mg

    2 g 0.013 mg

    5 g 0.015 mg

    10 g 0.018 mg

    20 g 0.018 mg

    50 g 0.046 mg

    100 g 0.12 mg

    200 g 0.14 mg

    500 g 0.89 mg

    1 kg 0.96 mg

    2 kg 1.5 mg

    5 kg 4.7 mg

    10 kg 0.012 g

    20 kg 0.018 g

    50 kg 9.3 g

    Signatories:

    1. Ching Kar Chien 2. Chew Siou Lian

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 8 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: FORCE

    SITE: CATEGORY I

    Instrument Calibrated/ Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Hardness Testing Machine (HRC)

    30 to 60 HRC 0.25 HRC Standard hardness block

    Force Indicating Device (Tension)

    0 N to 10 N 10 N to 50 N 50 N to 100 N

    0.0013 N 0.013N 0.13 N

    Dead Weights

    method based on ISO 7500-1:2018

    Force Indicating Device (Compression)

    0 N to 10 N 10 N to 50 N 50 N to 100 N

    100 N to 500 N

    0.0013 N 0.013 N 0.13 N 1.3 N

    Signatories:

    1. Kenny Ching Ah Hoo (except Force Indicating Device) 2. Eunice Wong Phaik Gaik (except Force Indicating Device) 3. Ching Kar Chien 4. Chew Chii Tsong (except Hardness Testing Machine)

    SCOPE OF CALIBRATION: FORCE

    Instrument Calibrated/ Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Durometer Hardness Spring force for 0.65 durometer point Durometer Calibrator

    ASTM D 2240:2015

    Type A, B & O

    Type C, D & DO

    Force Gauge / Push- Pull Gauge

    0 N to 10 N 10 N to 50 N 50 N to 500 N

    500 N to 1000 N

    ± 0.0011 N ± 0.011 N ± 0.080 N ± 0.80 N

    Dead weights method

    ISO 7500-1:2018

    Signatories:

    1. Kenny Ching Ah Hoo (except Durometer Hardness) 2. Eunice Wong Phaik Gaik (except Durometer Hardness) 3. Ching Kar Chien 4. Chew Chii Tsong (except Durometer Hardness)

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 9 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: PRESSURE

    SITE: CATEGORY I

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement

    Capability Expressed as an Uncertainty(±)*

    Remarks

    Pressure Indicating

    Devices (Pressure

    Gauge, Vacuum

    Gauge, Manometer,

    Magnehelic)

    Manometer -5.8 to 5.8 psi 0.00078 psi Comparison

    with Reference

    Vacuum -12 to 0 psi 0.022 psi Pressure

    Calibrator

    Pneumatic/Hydraulic 0 to 300 psi 0.049 psi

    Hydraulic 300 to 10000 psi 4.8 psi

    Signatories:

    1. Ching Kar Chien 2. Chew Siou Lian 3. Chew Chii Tsong

    SCOPE OF CALIBRATION: PRESSURE

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement

    Capability Expressed as an Uncertainty(±)*

    Remarks

    Pressure Indicating

    Devices (Pressure

    Gauge, Vacuum

    Gauge, Manometer,

    Magnehelic)

    Manometer -5.8 to 5.8 psi 0.00078 psi Comparison

    with Reference

    Vacuum -12 to 0 psi 0.022 psi Pressure

    Calibrator

    Pneumatic/Hydraulic 0 to 300 psi 0.049 psi

    Hydraulic 300 to 10000 psi 4.8 psi

    Signatories:

    1. Ching Kar Chien 2. Chew Siou Lian 3. Chew Chii Tsong

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 10 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: TORQUE

    SITE: CATEGORY I

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Torque Tools (Torque Wrench,

    Torque Driver Fixed or Adjustable)

    0 N.m to 1 N.m 0.0055 N.m Based on ISO 6789-1:2017

    Above 1 N.m to 5 N.m 0.048 N.m

    Signatories:

    1. Ching Kar Chien 2. Chew Chii Tsong

    SCOPE OF CALIBRATION: TORQUE

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Torque Measuring Devices

    0 N.m to 1 N.m Above 1 N.m to 10 N.m

    Above 10 N.m to 40 N.m Above 40 N.m to 300 N.m

    Above 300 N.m to 1000 N.m Above 1000 N.m to 1500 N.m

    0.012 N.m 0.020 N.M 0.042 N.M 0.34 N.m 1.1 N.m 2.4 N.m

    Calibration using dead weights and known radius of torque wheel / double-ended

    calibration beam

    Torque Tools (Torque

    Wrench, Torque Driver, Fixed or

    Adjustable)

    Up to 1 N.m Above 1 N.m to 5 N.m Above 5 N.m to 10 N.m

    Above 10 N.m to 40 N.m Above 40 N.m to 150 N.m Above 150 N.m to 600 N.m

    Above 600 N.m to 1000 N.m Above 1000 N.m to 1500 N.m

    0.0055 N.m 0.048 N.m 0.054 N.m 0.18 N.m 0.48 N.m 1.4 N.m 1.8 N.m 2.7 N.m

    Based on ISO 6789-1:2017

    Signatories:

    1. Kenny Ching Ah Hoo (except Torque Tools) 2. Eunice Wong Phaik Gaik (except Torque Tools) 3. Ching Kar Chien 4. Chew Chii Tsong (except Torque Measuring Devices) 5. Chew Siou Lian (except Torque Measuring Devices)

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 11 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: TEMPERATURE SITE: CATEGORY I

    Signatories:

    1. Ching Kar Chien 2. Chew Siou Lian 3. Chew Chii Tsong

    4. Nor Faeizah Binti Azmi (Temperature Sensor only)

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Temperature Enclosure

    -95 °C to -40 °C Above -40 °C to 200 °C

    Above 200 °C to 500 °C

    0.83 °C 0.23 °C 0.58 °C

    Using temperature sensor / logger

    based on DKD-R 5-7 /

    AS 2853-1986

    Humidity 10 % RH to 98 % RH 2.5 % RH Using Dry bulb &

    Enclosure Wet bulb

    10 °C to 95 °C 0.58 °C sensor / logger

    based on

    JTM K01-1991

    Temperature -90 °C to -80 °C 0.090 °C Comparison with

    Sensor Above -80 °C to -40 °C 0.072 °C PT 100 in Metrology

    Above -40 °C to 100 °C 0.043 °C Well / Liquid Bath /

    Above 100 °C to 300 °C 0.12 °C Temperature

    Above 300 °C to 500 °C 0.51 °C Block Calibrator

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 12 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: TEMPERATURE

    SITE: CATEGORY I

    Signatories:

    1. Ching Kar Chien 2. Chew Chii Tsong

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Temperature

    Simulator

    K -100 ˚C to 1300 ˚C 0.19 ˚C Measurement using

    Temperature Calibrator

    J -100 ˚C to 1200 ˚C 0.16 ˚C

    T -100 ˚C to 400 ˚C 0.18 ˚C

    E -100 ˚C to 950 ˚C 0.13 ˚C

    N -200 ˚C to 1300 ˚C 0.25 ˚C

    B 600 to 1800 ˚C 0.93 ˚C

    R 0 to 1700 ˚C 0.64 ˚C

    S 0 to 1700 ˚C 0.60 ˚C

    Pt 100 -100 to 800 ˚C 0.059 ˚C

    Temperature Indicator

    Electrical simulation using

    Temperature Calibrator based

    on EURAMET/cg-

    11/v.01

    K -100 to 1300 ˚C 0.14 ˚C

    J -100 to 1200 ˚C 0.12 ˚C

    T -100 to 400 ˚C 0.12 ˚C

    E -100 to 950 ˚C 0.10 ˚C

    N -200 ˚C to 1300 ˚C 0.16 ˚C

    B 600 to 1800 ˚C 0.50 ˚C

    R 0 to 1700 ˚C 0.35 ˚C

    S 0 to 1700 ˚C 0.33 ˚C

    Pt 100 -100 to 800 ˚C 0.065 ˚C

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 13 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: TEMPERATURE

    Signatories:

    1. Ching Kar Chien 2. Chew Chii Tsong 3. Nor Faeizah Binti Azmi (Temperature Sensor only)

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Temperature Sensor -90 ˚C to -40 ˚C Above -40 ˚C to 100 ˚C Above 100 ˚C to 300 ˚C Above 300 ˚C to 500 ˚C

    0.050 ˚C 0.032 ˚C 0.10 ˚C 0.51 ˚C

    Comparison with PT 100 / Type K-

    Sensor in Metrology Well /

    Liquid Bath / Temperature

    Block Calibrator

    Surface Sensor 0 ˚C to 50 ˚C 0.50 ˚C Comparison with

    50 ˚C to 200 ˚C 0.55 ˚C reference

    200 ˚C to 300 ˚C 0.71 ˚C surface sensor

    on electronic

    hotplate /

    equalizing block

    of dry bath

    Temperature Block

    Calibrator

    -20 ˚C to 300 ˚C 300 ˚C to 600 ˚C 600 ˚C to 700 ˚C

    0.061 ˚C 0.12 ˚C 1.0 ˚C

    Comparison with PT 100 /

    Thermocouple Type-K

    EURAMET cg-13 Version 3.0

    Radiation / Infrared Thermometer

    -30 ˚C to 0 ˚C Above 0 ˚C to 100 ˚C

    Above 100 ˚C to 200 ˚C Above 200 ˚C to 300 ˚C Above 300 ˚C to 400 ˚C Above 400 ˚C to 500 ˚C Above 500 ˚C to 650 ˚C

    0.72 ˚C 0.44 ˚C 0.78 ˚C 1.2 ˚C 1.7 ˚C 2.1 ˚C 2.7 ˚C

    Comparison with PT100 and Type K

    In Blackbody Source ASTM E 2847:2014

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 14 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: TEMPERATURE

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement

    Capability Expressed as an Uncertainty(±)*

    Remarks

    Themohygro Devices

    A) Relative Humidity 20 %rh to 80 %rh 1.8 %rh Comparison with

    80 %rh to 90 %rh 2.2 %rh Reference Standard

    in

    Temperature 0 °C to 60 °C 0.10 °C Temperature/Humidity

    Chamber

    B) Relative Humidity 11 %rh 1.1 %rh Fixed Point

    (Fixed Point) 33 %rh 1.3 %rh Calibration in Salt

    75 %rh 1.4 %rh Chamber

    97 %rh 1.7 %rh

    Temperature 25 °C 0.31 °C

    Liquid – In – Glass 0 °C to 200 °C 0.10 °C Comparison with

    Thermometer PT100 in a stirred

    (Total Immersion) liquid bath

    Signatories:

    1. Ching Kar Chien 2. Chew Siou Lian 3. Chew Chii Tsong

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 15 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: TEMPERATURE

    Signatories:

    1. Ching Kar Chien 2. Chew Chii Tsong

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Temperature

    Indicator

    K -200 to 0 °C 0.14 °C Electrical

    0 to 1370 °C 0.12 °C simulation using

    multi-product

    J -210 to 0 °C 0.12 °C calibrator based

    0 to 1200 °C 0.10 °C on ITS-90 Table

    T -200 to 0 °C 0.12 °C

    0 to 400 °C 0.10 °C

    -200 to 0 °C 0.10 °C

    E

    N

    0 to 1300 °C 0.10 °C

    -200 to 0 °C 0.16 °C

    0 to 1300 °C 0.10 °C

    B 250 to 600 °C 0.50 °C

    600 to 1820 °C 0.15 °C

    -50 to 0 °C 0.35 °C

    R

    0 to 1760 °C 0.14 °C

    S -50 to 0 °C 0.33 °C

    0 to 1760 °C 0.16 °C

    Pt 100 -200 to 850 °C 0.065 °C

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 16 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: TEMPERATURE

    Signatories:

    1. Ching Kar Chien 2. Chew Chii Tsong

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Temperature

    Simulator

    K -200 to 0 °C 0.19 °C Measurement

    0 to 1370 °C 0.13 °C using multimeter

    based on ITS-90

    J -210 to 0 °C 0.16 °C Table

    0 to 1200 °C 0.11 °C

    T -200 to 0 °C 0.18 °C

    0 to 400 °C 0.10 °C

    E -200 to 0 °C 0.13 °C

    0 to 1000 °C 0.10 °C

    -200 to 0 °C 0.25 °C

    N

    0 to 1300 °C 0.11 °C

    B 250 to 600 °C 0.93 °C

    600 to 1820 °C 0.23 °C

    -50 to 0 °C 0.64 °C

    R

    0 to 1760 °C 0.21 °C

    S -50 to 0 °C 0.60 °C

    0 to 1760 °C 0.24 °C

    Pt 100 -200 to 850 °C 0.059 °C

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 17 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: VOLUME

    SITE: CATEGORY 1

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    pH Meter 4.01 pH 0.03 pH Standard Buffer 7.01 pH 0.03 pH Solutions

    10.01 pH

    0.04 pH

    Conductivity Meter

    84 µS/cm

    1413 µS/cm

    2 µS/cm

    10 µS/cm

    Calibrated NIST

    Traceable Standard solution based on ASTM D 1125-14

    Signatories:

    1. Chew Siou Lian 2. Ching Kar Chien

    SCOPE OF CALIBRATION: VOLUME

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    pH Meter 4.01 pH 0.03 pH Standard Buffer 7.01 pH 0.03 pH Solutions

    10.01 pH

    0.03 pH

    Conductivity Meter

    84 µS/cm

    1413 µS/cm

    2 µS/cm 9 µS/cm

    Calibrated NIST

    Traceable Standard solution based on ASTM D 1125-14

    Refractometer / Sucrose Mass

    Fraction / Refractive Index

    0 % to 50 % Brix

    (1.333 nD ~ 1.420 nD)

    ± 0.32 % Brix

    Sucrose powder with analytical

    balance

    Signatories:

    1. Chew Siou Lian 2. Ching Kar Chien

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 18 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: VOLUME

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Volumetric 1 to 20 µl 0.040 µl Apparatus Above 20 to 100 µl 0.10 µl Gravimetric

    (To Deliver) Above 100 to 200 µl 0.15 µl Method based Above 200 to 1000 µl 0.48 µl on ISO 8655-

    Piston-Operated Above 1000 to 5000 µl 3.4 µl 6:2002 Pipette, Type A

    One-Mark 1 to 10 ml 0.0066 ml Pipette Above 10 to 100 ml 0.019 ml

    Above 100 to 200 ml 0.029 ml Above 200 to 500 ml 0.069 ml Above 500 to 1000 ml 0.15 ml

    Volumetric 1 to 10 ml 0.041 ml Apparatus Above 10 to 100 ml 0.24 ml

    (To Contain) Above 100 to 200 ml 0.35 ml Above 200 to 500 ml 0.58 ml

    Measuring Above 500 to 1000 ml 1.6 ml Cylinder Flask

    Signatories:

    1. Chew Siou Lian 2. Ching Kar Chien

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 19 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF SCOPE OF CALIBRATION: ELECTRICAL SCOPE: CATEGORY I

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Measuring Instruments

    DC Voltage

    0 mV to 320 mV 0.32 V to 3.2 V 3.2 V to 32 V 32 V to 320 V

    320 V to 1050 V

    5.7 μV/V + 1.1 μV 8.1 μV/V + 6.4 μV 13 μV/V + 2.4 μV 12 μV/V + 33 μV

    4.5 μV/V + 5.1 mV

    Generation using

    Calibrator model

    Wavetek 9100

    AC Voltage 0 V to 1050 V See Matrix A

    DC Current

    0 µA to 320 µA 0.32 mA to 3.2 mA 3.2 mA to 32 mA 32 mA to 320 mA

    0.32 A to 3.2 A 3.2 A to 20 A

    390 μA/A + 5.2 mA 5.9 μA/A + 0.13 mA 34 μA/A + 0.038 mA 33 μA/A + 0.0012 mA 0.29 mA/A + 0.11 mA 0.58 mA/A + 0.55 mA

    AC Current 0 A to 20 A See Matrix B

    Resistance 0 Ω to 40 Ω

    40 Ω to 400 Ω 400 Ω to 4 kΩ 4 kΩ to 40 kΩ

    40 kΩ to 400 kΩ 400 kΩ to 4 MΩ 4 MΩ to 40 MΩ

    40 MΩ to 400 MΩ

    0.055 mΩ/Ω + 0.18 mΩ 0.017 mΩ/Ω + 1.7 mΩ 0.013 mΩ/Ω + 3.9 mΩ 0.019 mΩ/Ω + 19 mΩ 0.035 mΩ/Ω + 1.3 Ω 0.11 mΩ/Ω + 26 Ω

    0.020 mΩ/Ω + 0.43 kΩ 0.59 mΩ/Ω + 40 kΩ

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 20 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF SCOPE OF CALIBRATION: ELECTRICAL SCOPE: CATEGORY I

    Matrix A

    AC Voltage Measurement

    Range Frequency

    Hz kHz

    0 to 10 10 to 50 0.05 to 1 1 to 30 30 to 50 50 to 100

    0 mV to 320 mV 0.0007 + 0.12

    0.0027 + 0.084

    0.00024 + 0.084

    0.00028 + 0.21

    0.00093 + 0.21

    0.00028 + 0.47

    320 mV to 3.2 V 0.34 + 0.006

    0.24 + 0.0093

    0.2 + 0.0092

    0.66 + 0.00010

    0.44 + 0.11 1.5 + 0.00010

    3.2 V to 32 V 0.42 +0.56 0.33 + 0.55 0.33 + 0.54 0.54 + 1.2 0.62 + 2.7 1.6 + 4.0

    32 V to 320 V 0.34 + 7.2 0.35 + 3.4 0.35 + 3.4 0.11 + 32

    320 V to 1050 V 0.68 + 130 0.68 + 130 1.1 + 240

    The expanded uncertainties given in above table are expressed in mV/V + mV

    Matrix B

    AC Current Measurement

    Range Frequency (Hz )

    Frequency ( kHz )

    0 to 10 0.01 to 3 3 to 10 10 to 30

    0 to 320 µA 0.11 mA/A + 285 mA

    0.096 mA/A + 285 mA

    0.068 mA/A + 285 mA

    0.089 mA/A + 285 mA

    320 µA to 3.2 mA 0.16 mA/A + 0.27 µA

    0.27 mA/A + 0.23 µA

    0.22 mA/A + 0.24 µA

    0.22 mA/A + 0.25 µA

    3.2 mA to 32 mA 0.28 mA/A + 0.32 μA

    0.27 mA/A + 0.23 μA

    0.27 mA/A + 0.21 μA

    0.47 mA/A + 0.26 μA

    32 mA to 320 mA 0.68 mA/A + 13 μA

    0.67 mA/A +13 μA

    0.68 mA/A + 13 μA

    0.76mA/A + 9.2 μA

    0.32 A to 3.2 A 0.50 mA/A + 0.30 mA

    0.69 mA/A + 0.067 mA

    0.69 mA/A + 0.067 mA

    3.2 A to 20 A

    - 0.35 mA/A - -

    Signatories:

    1. Kenny Ching Ah Hoo 2. Gabriel Ching Kar Ee 3. Ching Kar Chien

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 21 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF SCOPE OF CALIBRATION: ELECTRICAL SCOPE: CATEGORY I

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Measuring

    Instruments

    Frequency 0.5 Hz to 320 Hz 29 ppm Generation using

    320 Hz to 3.2 kHz 29 ppm Calibrator model

    3.2 kHz to 32 kHz 29 ppm Wavetek 9100

    32 kHz to 3.2 MHz 29 ppm

    3.2 MHz to 10 MHz 29 ppm

    Capacitance 0.5 nF to 4 nF 4.9 mF/F

    4 nF to 40 nF 3.7 mF/F

    40 nF to 400 nF 2.4 mF/F

    400 nF to 4 µF 2.7 mF/F

    4 µF to 40 µF 3.7 mF/F

    40 µF to 400 µF 3.9 mF/F

    400 µF to 4 mF 3.9 mF/F

    4 mF to 40 mF 5.1 mF/F

    Resistance 10 mΩ to 90 mΩ 8.7 mΩ/Ω Direct

    100 mΩ to 900 mΩ 1.2 mΩ/Ω measurement

    1 Ω to 9 Ω 0.24 mΩ/Ω with TIME

    10 Ω to 90 Ω 0.17 mΩ/Ω Decade

    100 Ω to 900 Ω 0.16 mΩ/Ω Resistance Box

    1 kΩ to 9 kΩ 0.16 mΩ/Ω

    10 kΩ to 90 kΩ 0.16 mΩ/Ω

    100 kΩ to 900 kΩ 0.16 mΩ/Ω

    1 MΩ to 9 MΩ 0.16 mΩ/Ω

    10 MΩ to 90 MΩ 0.16 mΩ/Ω

    100 MΩ to 199.99 MΩ

    0.16 mΩ/Ω

    Clamp Meter

    DC Current (+/- polarities)

    - 50 Turn Coil 1.6 to 16 A 0.37 mA/A Generating using

    16 to 160 A 0.37 mA/A Calibrator model

    160 to 525 A 0.12 mA/A Wavetek 9100

    525 to 1000 A 0.58 mA/A with Current Coil

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 22 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF SCOPE OF CALIBRATION: ELECTRICAL SCOPE: CATEGORY I

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Clamp Meter

    AC Current - 50 Turn Coil

    1.6 to 16 A 10 to 100 Hz

    100 to 440 Hz

    1.6 to 16 A 10 to 100 Hz

    100 to 440 Hz

    1.6 to 16 A 10 to 100 Hz

    100 to 440 Hz

    1.3 mA/A 3.2 mA/A

    1.4 mA/A 3.4 mA/A

    1.3 mA/A 3.2 mA/A

    Generating using Calibrator model Wavetek 9100 with Current Coil

    Generating Instruments

    DC Voltage

    0 to 100 mV 100 mV to 1 V

    1 V to 10 V 10 V to 100 V

    100 V to 1000 V

    3.2 nV/V + 1.7 μV 7.7 μV/V + 0.85 μV 6.9 μV/V + 1.6 μV 4.8 μV/V + 21 μV 5.3 μV/V + 250 μV

    Measurement Keysight 3458A

    Digital Multimeter

    AC Voltage 0 to 1000 V See Matrix C

    DC Current

    0 to 100 μA

    100 μA to 1 mA 1 mA to 10 mA

    10 mA to 100 mA 100 mA to 1 A

    46 mA/A + 17 nA 7.5 μA /A + 14 nA 4.9 μA /A + 19 nA 5.6 μA/A + 12 nA

    0.014 mA/A + 2.9 μA

    1 A to 3 A

    1.5 mA/A + 2.0 mA

    Measurement Agilent 34401A Multimeter

    AC Current

    0 to 3 A

    See Matrix D

    Measurement

    Keysight 3458A Digital Multimeter

    Resistance 0 to 10 Ω 10 Ω to 100 Ω 100 Ω to 1 kΩ 1 kΩ to 10 kΩ

    10 kΩ to 100 kΩ 100 kΩ to 1 MΩ 1 MΩ to 10 MΩ

    10 MΩ to 100 MΩ

    42 nΩ/Ω + 0.32 mΩ 15 μΩ/Ω + 0.18 mΩ 13 μΩ/Ω + 0.44 mΩ 4.7 μΩ/Ω + 20 mΩ 4.8 μΩ/Ω + 66 mΩ 3.7 μΩ/Ω + 1.3 Ω 26 μΩ/Ω + 79 Ω

    130 μΩ/Ω + 38 kΩ

    Frequency 1 Hz to 40 Hz 40 Hz to 100 Hz

    100 Hz to 100 kHz 100 kHz to 10 MHz

    570 ppm 120 ppm 120 ppm 130 ppm

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 23 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF SCOPE OF CALIBRATION: ELECTRICAL SCOPE: CATEGORY I

    Generating Instruments

    AC Voltage:

    Matrix C

    Frequency

    Voltage

    Hz kHz

    0 to 40 0.04 to 1 1 to 20 20 to 50 50 to 100

    0 to 10 mV 2.9 mV/V 0.88 mV/V 0.55 mV/V 0.31 mV/V 1.1 mV/V + 19 μV + 3.7 μV + 7.4 μV + 15 μV + 15 μV

    10 mV to 100 mV 4.7 mV/V 0.12 mV/V 0.11 mV/V 0.80 mV/V 0.71 mV/V + 73 μV + 12 μV + 12 μV + 9.6 μV + 18 μV

    100 mV to 1 V 109 μV/V 114 μV/V 102 μV/V 184 μV/V 185 μV/V + 18 μV + 12 μV + 12 μV + 71 μV + 70 μV

    1 V to 10 V 76 μV/V 77 μV/V 69 μV/V 188 μV/V 190 μV/V + 50 μV + 49 μV + 45 μV + 67 μV + 66 μV

    10 V to 100 V 79 μV/V 80 μV/V 46 μV/V 180 μV/V 700 μV/V + 19 μV + 19 μV + 1.2 mV + 4.7 mV + 9.4 mV

    100 V to 1000 V 68 μV/V 68 μV/V - - - + 1.2 mV + 1.2 mV

    The expanded uncertainties given in above table are expressed in mV/V

    AC Current:

    Matrix D

    Frequency

    Voltage

    Hz kHz Measuring

    Instrument

    0 to 50 0.05 to 1 1 to 5 5 to 30

    0 A to 1 mA 0.26 mA/A 0.17 mA/A 0.21 mA/A 0.92 mA/A Keysight + 0.38 μA + 70 nA + 59 nA + 59 nA 3458A

    1 mA to 10 mA 0.19 mA/A 0.23 mA/A 0.23 mA/A 0.15 mA/A Keysight + 0.45 μA + 9.9 nA + 45 nA + 0.84 nA 3458A

    10 mA to 100 mA 0.21 mA/A 0.21 mA/A 0.21 mA/A 0.21 mA/A Keysight + 0.21 μA + 0.17 μA + 0.17 μA + 0.17 μA 3458A

    100 mA to 1 A 4.7 mA/A 0.17 mA/A 1.2 mA/A - Keysight + 240 μA + 24 μA + 240 μA 3458A

    1 A to 3 A 0.81 mA/A 0.81 mA/A 0.81 mA/A - Agilent

    + 0.15 mA + 0.15 mA + 0.15 mA 34401A The expanded uncertainties given in above table are expressed in mA/A

    Signatories:

    1. Gabriel Ching Kar Ee 2. Ching Kar Chien

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 24 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF SCOPE OF CALIBRATION: ELECTRICAL

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Measuring

    Instrument

    DC Voltage 0 V to 320 mV 5.7 μV/V + 1.1 μV Generation using

    0.32 V to 3.2 V 8.1 μV/V + 6.4 μV calibrator model

    3.2 V to 32 V 13 μV/V + 2.4 μV Wavetek 9100

    32 V to 320 V 12 μV/V + 33 μV

    320 V to 1050 V

    4.5 μV/V + 5.1 mV

    AC Voltage 0 V to 1050 V See Matrix A

    DC Current 0 A to 320 µA 390 μA/A + 5.2 mA

    0.32 mA to 3.2 mA 5.9 μA/A + 0.13 mA

    3.2 mA to 32 mA 34 μA/A + 0.038 mA

    32 mA to 320 mA 33 μA/A + 0.0012 mA

    0.32 A to 3.2 A 0.29 mA/A + 0.11 mA

    3.2 A to 20 A

    0.58 mA/A + 0.55 mA

    AC Current 0 A to 20 A See Matrix B

    Resistance 0 Ω to 40 Ω 0.055 mΩ/Ω + 0.18 mΩ

    40 Ω to 400 Ω 0.017 mΩ/Ω + 1.7 mΩ

    400 Ω to 4 kΩ 0.013 mΩ/Ω + 3.9 mΩ

    4 kΩ to 40 kΩ 0.019 mΩ/Ω + 19 mΩ

    40 kΩ to 400 kΩ 0.035 mΩ/Ω + 1.3 Ω

    400 kΩ to 4 MΩ 0.11 mΩ/Ω + 26 Ω

    4 MΩ to 40 MΩ 0.020 mΩ/Ω + 0.43 kΩ

    40 MΩ to 400 MΩ

    0.59 mΩ/Ω + 40 kΩ

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 25 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    Matrix A AC Voltage Measurement

    The expanded uncertainties given in above table are expressed in mV/V + mV

    Matrix B AC Current Measurement

    Range Frequency Frequency

    (Hz ) ( kHz )

    0 to 10 0.01 to 3 3 to 10 10 to 30

    0 to 320 µA 0.11 mA/A 0.096 mA/A 0.068 mA/A 0.089 mA/A

    + 285 mA + 285 mA + 285 mA + 285 mA

    320 µA to 3.2 mA 0.16 mA/A 0.27 mA/A 0.22 mA/A 0.22 mA/A

    + 0.27 μA + 0.23 μA + 0.24 μA + 0.25 μA

    3.2 mA to 32 mA 0.28 mA/A 0.27 mA/A 0.27 mA/A 0.47 mA/A

    + 0.32 μA + 0.23 μA + 0.21 μA + 0.26 μA

    32 mA to 320 mA 0.68 mA/A 0.67 mA/A 0.68 mA/A 0.76 mA/A

    + 13 μA + 13 μA + 13 μA + 9.2 μA

    0.32 A to 3.2 A 0.50 mA/A 0.69 mA/A 0.69 mA/A -

    + 0.30 mA + 0.067 mA + 0.067 mA

    3.2 A to 20 A

    - 0.35 mA/A

    - -

    Signatories:

    1. Kenny Ching Ah Hoo 2. Gabriel Ching Kar Ee 3. Ching Kar Chien

    Range Frequency

    Hz kHz

    0 to 10 10 to 50 0.05 to 1 1 to 30 30 to 50 50 to 100

    0 mV to 320 mV 0.0007 + 0.12

    0.0027 + 0.084

    0.00024 + 0.084

    0.00028 + 0.21

    0.00093 + 0.21

    0.00028 + 0.47

    320 mV to 3.2 V 0.34 + 0.006

    0.24 + 0.0093

    0.2 + 0.0092

    0.66 + 0.00010

    0.44 + 0.11

    1.5 + 0.00010

    3.2 V to 32 V 0.42 +0.56 0.33 + 0.55 0.33 + 0.54 0.54 + 1.2 0.62 + 2.7 1.6 + 4.0

    32 V to 320 V 0.34 + 7.2 0.35 + 3.4 0.35 + 3.4 0.11 + 32

    320 V to 1050 V 0.68 + 130 0.68 + 130 1.1 + 240

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 26 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF SCOPE OF CALIBRATION: ELECTRICAL

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Measuring

    Instruments

    Frequency 0.5 Hz to 320 Hz 320 Hz to 3.2 kHz 3.2 kHz to 32 kHz 32 kHz to 3.2 MHz 3.2 MHz to 10 MHz

    29 ppm Generation

    29 ppm using Calibrator

    29 ppm model Wavetek

    29 ppm 9100

    29 ppm

    Capacitance 0.5 to 4 nF 4.9 mF/F

    4 nF to 40 nF 3.7 mF/F

    40 nF to 400 nF 2.4 mF/F

    400 nF to 4 µF 2.7 mF/F

    4 µF to 40 µF 3.7 mF/F

    40 µF to 400 µF 3.9 mF/F

    400 µF to 4 mF 3.9 mF/F

    4 mF to 40 mF 5.1 mF/F

    Resistance 10 mΩ to 90 mΩ 100 mΩ to 900 mΩ

    1 Ω to 9 Ω 10 Ω to 90 Ω

    100 Ω to 900 Ω 1 kΩ to 9 kΩ

    10 kΩ to 90 kΩ 100 kΩ to 900 kΩ

    1 MΩ to 9 MΩ 10 MΩ to 90 MΩ

    100 MΩ to 199.99 MΩ

    8.7 mΩ/Ω 1.2 mΩ/Ω 0.24 mΩ/Ω 0.17 mΩ/Ω 0.16 mΩ/Ω 0.16 mΩ/Ω 0.16 mΩ/Ω 0.16 mΩ/Ω 0.16 mΩ/Ω 0.16 mΩ/Ω 0.16 mΩ/Ω

    Direct

    measurement with TIME Decade

    Resistance Box

    Clamp Meter

    DC Current (+/- polarities)

    - 50 Turn Coil 1.6 A to 16 A 0.37 mA/A Generating using

    16 A to 160 A 0.37 mA/A Calibrator model

    160 A to 525 A 0.12 mA/A Wavetek 9100

    525 A to 1000 A 0.58 mA/A with Current Coil

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 27 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: ELECTRICAL

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Clamp Meter

    Generating using Calibrator model Wavetek 9100

    with Current Coil

    AC Current 1.6 A to 16 A

    - 50 Turn Coil 10 Hz to 100 Hz 1.3 mA/A

    100 Hz to 440 Hz 3.2 mA/A

    16 A to 160A

    10 Hz to 100 Hz 1.4 mA/A

    100 Hz to 440 Hz 3.4 mA/A

    160 A to 1000 A

    10 Hz to 100 Hz 1.3 mA/A

    100 Hz to 440 Hz

    3.2 mA/A

    Generating

    Instruments

    DC Voltage 0 mV to 100 mV 36 nV/V + 1.7 µV Measurement

    100 mV to 1 V 7.7 µV/V + 0.85 µV using Keysight

    1 V to 10 V 6.9 µV/V + 1.6 µV 3458A Digital

    0 to 1 000 V See Ma trix C Multimeter

    10 V to 100 V 4.8 µV/V + 21 µV

    100 V to 1000 V

    5.3 µV/V + 250 µV

    AC Voltage 0 V to 1000 V See Matrix C

    DC Current 0 µA to 100 µA 46 mA/A + 17 nA

    100 µA to 1 mA 7.5 µA/A + 14 nA

    1 mA to 10 mA 4.9 µA/A + 19 nA

    10 mA to 100 mA 5.6 µA/A + 12 nA

    100 mA to 1 A 0.014 mA/A + 2.9 µA

    Measurement

    1 A to 3 A 1.5 mA/A + 2.0 mA using Agilent

    34401A Multimeter

    AC Current 0 to 3 A See Matrix D

    Measurement using Keysight 3458A Digital

    Multimeter

    Resistance 0 Ω to 10 Ω

    10 Ω to 100 Ω 100 kΩ to 1 kΩ 1 kΩ to 10 kΩ

    10 kΩ to 100 kΩ 100 kΩ to 1 MΩ 1 MΩ to 10 MΩ

    10 MΩ to 100 MΩ

    42 µΩ/Ω + 0.32 mΩ 15 µΩ/Ω + 0.18 mΩ 13 µΩ/Ω + 0.44 mΩ 4.7 µΩ/Ω + 20 mΩ 4.8 µΩ/Ω + 66 mΩ 3.7 µΩ/Ω + 1.3 Ω 26 µΩ/Ω + 79 Ω

    130 µΩ/Ω + 38 kΩ

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 28 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: ELECTRICAL

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Generating

    Instruments

    Frequency 1 Hz to 40 Hz 570 ppm Measuring using

    40 Hz to 100 Hz 120 ppm SANWA CD

    100 Hz to 100 kHz 120 ppm 800a Multimeter

    100 kHz to 10 MHz 130 ppm

    Capacitance 1 µF to 10 µF 40 µF/F + 150 nF

    10 µF to 100 µF 1.2 mF/F + 0.12 µF

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 29 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    AC Voltage:

    Matrix C

    Frequency

    Voltage

    Hz kHz

    0 to 40 0.04 to 1 1 to 20 20 to 50 50 to 100

    0 to 10 mV 2.9 mV/V 0.88 mV/V 0.55 mV/V 0.31 mV/V 1.1 mV/V + 19 μV + 3.7 μV + 7.4 μV + 15 μV + 15 μV

    10 mV to 100 mV 4.7 mV/V 0.12 mV/V 0.11 mV/V 0.80 mV/V 0.71 mV/V + 73 μV + 12 μV + 12 μV + 9.6 μV + 18 μV

    100 mV to 1 V 109 μV/V 114 μV/V 102 μV/V 184 μV/V 185 μV/V + 18 μV + 12 μV + 12 μV + 71 μV + 70 μV

    1 V to 10 V 76 μV/V 77 μV/V 69 μV/V 188 μV/V 190 μV/V + 50 μV + 49 μV + 45 μV + 67 μV + 66 μV

    10 V to 100 V 79 μV/V 80 μV/V 46 μV/V 180 μV/V 700 μV/V + 19 μV + 19 μV + 1.2 mV + 4.7 mV + 9.4 mV

    100 V to 1000 V 68 μV/V 68 μV/V - - - + 1.2 mV + 1.2 mV

    AC Current:

    Matrix D

    Frequency

    Voltage

    Hz kHz Measuring

    Instrument

    0 to 50 0.05 to 1 1 to 5 5 to 30

    0 A to 1 mA 0.26 mA/A 0.17 mA/A 0.21 mA/A 0.92 mA/A Keysight + 0.38 μA + 70 nA + 59 nA + 59 nA 3458A

    1 mA to 10 mA 0.19 mA/A 0.23 mA/A 0.23 mA/A 0.15 mA/A Keysight + 0.45 μA + 9.9 nA + 45 nA + 0.84 nA 3458A

    10 mA to 100 mA 0.21 mA/A 0.21 mA/A 0.21 mA/A 0.21 mA/A Keysight + 0.21 μA + 0.17 μA + 0.17 μA + 0.17 μA 3458A

    100 mA to 1 A 4.7 mA/A 0.17 mA/A 1.2 mA/A - Keysight + 240 μA + 24 μA + 240 μA 3458A

    1 A to 3 A 0.81 mA/A 0.81 mA/A 0.81 mA/A - Agilent

    + 0.15 mA + 0.15 mA + 0.15 mA 34401A

    Signatories:

    1. Gabriel Ching Kar Ee 2. Ching Kar Chien

    http://www.jsm.gov.my/cab-directories

  • Schedule

    SKIM AKREDITASI MAKMAL MALAYSIA (SAMM) LABORATORY ACCREDITATION SCHEME OF MALAYSIA

    MS ISO/IEC 17025

    Issue date: 22 February 2019 Valid until: 15 October 2020

    NO: SAMM 256 (Issue 3, 22 February 2019 replacement of SAMM 256 dated 2 November 2017)

    Page: 30 of 30

    Scan t

    his

    QR

    Co

    de

    or

    vis

    it w

    ww

    .jsm

    .go

    v.m

    y/c

    ab

    -dir

    ecto

    ries f

    or

    the c

    urr

    ent

    sco

    pe o

    f a

    ccre

    ditatio

    n

    SCOPE OF CALIBRATION: TIME AND FREQUENCY SITE: CATEGORY I

    Instrument Calibrated/

    Measurement Parameter

    Range

    Calibration and Measurement Capability

    Expressed as an Uncertainty(±)*

    Remarks

    Stopwatch and Timer

    0 to 9 hours 0.35 sec

    Time measurement according to NIST

    stopwatch and timer calibration

    Tachometer

    (rpm measuring devices)

    (Non-contact) 0 to 599 rpm

    600 to 30,000 rpm

    25 ppm

    3.6 ppm + 0.013 rpm

    Frequency Generator with Agilent 34401A

    Multimeter

    (Contact) 0 to 5,000 rpm

    1.6 rpm

    Comparison with

    Reference Tachometer

    Signatories:

    1. Gabriel Ching Kar Ee 2. Ching Kar Chien 3. Chew Chii Tsong

    SCOPE OF CALIBRATION: TIME AND FREQUENCY

    Instrument Calibrated/

    Measurement Parameter

    Range Calibration and Measurement Capability Expressed as an

    Uncertainty(±)* Remarks

    Stopwatch and Timer

    0 to 9 hours 0.11 sec Time measurement according to NIST

    stopwatch and timer calibration

    Tachometer (rpm measuring

    devices)

    (Non-contact) 0 to 599 rpm

    600 to 99,999 rpm

    25 ppm 12 ppm + 0.005 rpm

    Frequency Generator with Universal Counter

    HP 5335A

    (Contact) 0 to 5,000 rpm

    1.6 rpm

    Comparison with Reference Tachometer

    Signatories:

    1. Gabriel Ching Kar Ee 2. Ching Kar Chien 3. Chew Chii Tsong