Paging Station

SPS 8 sept 2016

Page 2: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Content

1 Overview

2 Connections

3 Basic use and configuration

4 Use and advanced settings

Page 3: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Overview 1

SPS 8 overview

The SPS-8 is a paging station designed specifically for the BlueLine system and is

compatible with DigiLine. This guide describes the features of the SPS 8 as well as

its functionality..

Dimensions: 210 x 40 x 135 mm

Weight: 620g

Page 4: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

CONNECTIONS 2

SPS 8 connection ports:

Page 5: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Ethernet port, for the connection of SPS 8 to the local network. It is compatible with PoE, therefore it can be supplied through the Ethernet port, avoiding the need of connecting it to an external power supply. It must be taken under consideration that for the direct conection to a PC it is necessary to use a cross network cable (it is not necessary unless your System is compatible with Auto-MDIX).

Euroblock A connection, to connect the external power supply source (+5VDC)and the alarm System. It is usually an open contact. It can be programmed with one or several OSC commands that can be assigned to the alarm event.

Euroblock B connection, to connect to the the monitor audio output. The signal provided by this connection is the same that the one of the Ethernet. It is an unbalanced audio output.

RCA connection, to connect the audio source of the auxiliary input.

XLR-3 base, to connect a dynamic microphone to the SPS 8. If other type of microphone is used, it could damage the paging station.

Page 6: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

USING & BASIC SETUP

3

Buttons

All basic control functions are made through physic buttons placed in frontal panel of SPS 8.

Botones de selección de zona

These 8 multi-function programmable buttons are placed at the left hand of the control board. By default, each button is preset to work with a specific zone (from 1 to 8). It is possible to program and assign the diferent advanced functions to each button through WorkCAD software:

1-It is possible to assign an OSC command or series of OSC to each one of the buttons in order to program one or several actions.

2-it is possible to assign one or several zones to a zone selection button, thus it can work as a multi-zone selection button.

Any action or command assigned to the zone selection button can be triggered when “TALK” is pressed.

Push to Talk button

Placed on the low part of the central zone of the control board, when pressed every device which has been previously selected through the zone selection buttons, stop their emission to give preference to SPS 8 microphone. It is mandatory to keep it pressed when talking. Once the button is not pressed, every device go back to its previous state.

Botón de selección de entrada de audio auxiliar

It is placed in the central area of the board. When pressed, it activates the auxiliary audio input in order to be able to select whether ot use the microphone or the auxiliary audio. When the button is pressed for more than 5 seconds, the Station starts working in “AUX” mode, as a streamer which broadcasts seamless (no need to press the “TALK” button) the auxiliary audio input source connected to the RCA of the rear panel. In this mode, if the “TALK” button is pressed, the microphone will have priority over the auxiliar audio input, being capable of stoping the broadcast and activating the

Page 7: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

microphone until the button is released. When released, the Station goes back to its previous mode, which in this example is “AUX-IN”. In the case of a reset or shut down, its working mode keeps saved.

Unselection button

It is placed in the central area of the board, the “CLR” button, when pressed, any other activated zone button will be automatically deactivated.

Preset selection button

It is placed in the righ hand of the board and is composed of 4 multi-function buttons that can be programmed. One of these buttons is set by default to actívate the 8 zone selection buttons. The program and function assignment for each button can be made in two different ways depending on the requirements:

1-Basic: To program a preset button to select several zones. For this, users have to select the zone that they want to use through the zone selection buttons from 1 to 8.

Once the zones have been selected, users have to keep pressed the “Clear” button while pressing the preset button (from 1 to 4) in which we want to save the configuration. SPS 8 will indicate us that the preset has been correctly recorded by turning off every state LED.

Page 8: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

2-Advanced: It is made through WorkCAD Software. It is possible to assign an OSC command or series of commands to each one of the buttons available in order to program one or more actions. In the following updates, it will be possible to configure the buttons as “Push” (to work as a push button) or “Toggle” (to work as a switch). SPS 8’s preset buttons can be configured to interact with different components of an installation, from turning on and off the lighting to start an alarm or open a door.

Page 9: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

ADVANCED CONFIGURATION 4 ADVANCED

Using WorkCAD

All advanced control functions must be made using WorkCAD software. It can be downloaded from Workpro website.

SPS 8 detection with WorkCAD

Start WorkCAD and select the “Network” tab to see the devices which are connected to the network.

When users place the mouse over “SPS 8”, they can see up to 3 different icons:

^: It indicates that the devices is not updated. +: Clicking on this icon, users will add the device to the Project. It has to be taken under consideration that if the device is not updated, it can’t be added to the Project.

i : When users place the mouse over this icon, it will be shown information

about the device (fixed IP, dynamic IP, name, versión, etc.)

Page 10: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Getting SPS-8 information in WorkCAD

If you want to obtain information about a device, place the mouse over “i” icon of desired device.

Update of a SPS 8 in WorkCAD

After the instalation of the BlueLine devices, it is recommended to update all of them to the latest version, with bug-fix and new functionalities. The steps to take in the update of a devices are: 1.Start WorkCAD and go to the “Network” tab, where we will find every BlueLine devices available on the network. 2.When moving the mouse over the name of the device, if the icon “^” is shown, we should update the device.

Page 11: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

3.Click on the "^" icon (if shown) in order to update the device.

If selecting “Yes” you see an error message, please check that the IP range of the PC and the WorkCAD is the same tan the BlueLine device that you mean to update.

SPS-8

Page 12: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

4.Click on “YES” and the update process will start.

5.During the update process, the progress bar will stop for a few seconds when the device is auto-reseting. Please, wait and do not disconnect the device until the process has ended.

6. When the update is eneded, WorkCAD will show a message informing that the process has been done successful.

Change the name of a SPS-8 with WorkCAD

1- To change the name of a device it is necessary to add it to the Project (clicking on the “+” icon of the “Network” tab). The device will be add to the “Project Inspector” window of the project.

Page 13: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

2- Right click on the name of the device. Select “Rename” from the list of option that

will be shown.

Page 14: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

3-Give a new name to the device.

One the name or IP address of a device has been changed, it is highly advisable to restart the device to correctly save the data.

Change the IP address of a SPS 8 with WorkCAD

1-Right click on the name of the device. Select “Change static IP” from the list of option that will be shown.

Page 15: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

2- Give a new IP address to the device.

Once modified the name or IP address, it is advisable to restart the device in order to save the data correctly

Restart of a SPS-8 from WorkCAD

1- Right click on the name of the device. Select “RebootDevice” from the list of option that will be shown

2- WorkCAD will ask users for a confirmation to restart the device.

Page 16: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Selection of the broadcast channel

From WorkCAD, we select the channel which is going to Broadcast the SPS 8. In the “BlueLine System” panel, we will choose the “Stand Alone” option to adjust the broadcast channel through the rotatory Switch of the SPS 8 or “Set Source” to adjust the broadcast channel by introducing a specific channel number.

Zone selection

By default, every emitter of BlueLine Digital System belong to zone -1. If you want to change the emitter of the zone, keep in mind that zone 0 and zone 1 are taken for “Broadcast” and “Receivers”, respectively.

Assignment of functions to each zone and preset selection Button

From the menu “Zone & Presets” it is possible to set advanced configurations for each zone and preset button

Page 17: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

1º-Click over the “Configure button” and select the button you want to assign an specific function to.

2º- We choose whether the command will be triggered on activate or deactivate.

3º-Set the IP address of the device we want to send the message to. If we want to send a message to the whole network, we should introduce: 255.255.255.255.

Page 18: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Then we need to specify the port number. By default, BlueLine Digital System set the port number 3126 for the control pack reception. 4º- Introduce the command (ASCII) that we want to send. Keep in mind that WorkCAD incorporates an “OSC to ASCII” tool in case you need to check any command.

Once the command is written, click over “Add” and then “Apply” the changes.

Ajuste del tipo de codificación

Users can adjust the type of coding according to the requirements of the installation. For that, it is possible to choose PCM, ADPCM and MP3.

Page 19: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Deactivate the function IGMP querier

By default, all the senders of BlueLine Digital System have the IGMP querier function. However, it is just activated when the sender is assigned to the broadcast channel 0. If the SPS 8 is assigned to channel 0 but you don’t want to make it work with the querier function, this box must be checked.

Activate the function AUX Mode

If the “AUX Mode” function is actívate, the station will work then as sender, broadcasting seamless the source connected to the “AUX IN” input. For more information, please check the “AUX” button section of this presentation.

Priority configuration

When an installation requires 2 or more SPS 8, it is necessary to set and assign priorities. For that, before the installation, each paging station should be connected to a PC and, through WorkCAD, configure independently the SPS 8. Just one SPS 8 can be set as “Master”, which means that every command triggered by it has priority over the rest of SPS 8 connected to the network.

Page 20: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Alarm management

SPS 8 adds an alarm port through a circuit board and Euroblock type. By default, the alarm function hasn’t any function assigned. If users want to assign a function, it is possible to do it using WorkCAD. Users can set advanced functions when the activation of the alarm is done, thus beside triggering the channel priority, it is possible to trigger other commands to interact with doors, signals, sirens… The command and function management to the alarm port is done through WorkCAD. It is possible to add these commands using the alarm configuration menu. The alarm works as the 4 preset buttons, with the exception that it is triggered through the alarm connection.

Page 21: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Setting the preset keys such as Paging the zone selection keys

The SPS-8 has 8 zone selection access keys. It is possible to extend these keys

virtually using the 4 Preset keys as a paging mode, being able to have access

to the selection of up to 32 zones.

The steps to follow are those:

1- Select the preset key.

2- Select the preset key that we want to configure as "Paging" between

pages of zones. In the IP field we introduce "127.0.0.1" and in the Port

field we enter "9000"

Page 22: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

3- We turn off all the LEDs on the preset keys by command:

//sps8/selectPreset/[1,2,3,4];i;0;

Press "Add" to add the command.

4- We indicate the page that we want to select with that key by means of

the command:

//sps8/zonePage;i;page number;

Page number = 1 to select the zones 1-8

a. To select zone 9-16

b. To select zone 17-24

c. To select zone 25-32

Press "Add" to add the command.

5- We turn on the Led of the selected preset with the command:

//sps8/selectPreset/page number;i;1;

número de página = 1 To iluminate the preset led 1 2 To iluminate the preset led 2

3 To iluminate the preset led 3

4To iluminate the preset led 4

Page 23: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Press "Add" to add the command and press "Apply" to apply the changes.

NOTES:

If you have stored a command on some of the zone selection keys, it will be

executed regardless of the page you are in.

There is no limited number of pages, here it is indicated to choose between

the first four pages, however, it is possible to configure an SPS8 for zones 1-

32 and another SPS8 for zones 33-64 and so on.

Ding Dong sound emission setting at startup

The SPS-8 can generate a Ding Dong before sending the message. The

microphone will not be operational until the melody is finished. Once the

melody is finished, you can start the message.

Page 24: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

It is possible to generate a Ding Dong after sending the

message.

Setting SPS8 to maintain a selected zone

By default when the user releases the Push to Talk button after the message,

the selected zone is cleared, leaving the SPS8 clean for a new selection.

It is possible to configure the SPS8 to keep the selected zone always, even

after releasing the "Push to Talk" button. To do this, check the box: "Keep Zone

selection After Talking"

Page 25: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact

Setting the Push to Talk Button Behavior

You can select the behavior of the “Push to Talk” button. By default the button

behaves like a "Push button" which means that the user must hold the button

pressed to speak.

It is possible to configure the "Push to Talk" button to behave like "Toggle" which

means that after pressing the button once the microphone will remain active

until the "Push to Talk" is pressed again.

Page 26: Paging Station SPS 8 sept 2016 · 2017-04-20 · SPS 8 sept 2016. Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings. Overview 1 ... interact