Upload
others
View
7
Download
0
Embed Size (px)
Citation preview
PROČIŠĆAVANJE
OTPADNIH VODA
GRADOVA I INDUSTRIJE
Prof. dr. Laszlo Sipos
Sveučilište u Zagrebu
Fakultet kemijskog inženjerstva i
tehnologije, Zagreb
TEMELJNI PRINCIPI PROČIŠĆAVNJA
OTPADNIH VODA
Višak
mulja
UREĐAJI ZA PROČIŠĆAVANJE OTPADNIH VODA
POSTUPAK S AKTIVNIM MULJEM
1. Gruba i fina rešetka (GFR)
2. Aerirani pjeskolov mastolov(APM)
3. Primarna taložnica (PT)
4. Aeracijski spremnik (AS)
5. Sekundarna taložnica (ST)
GFR APM PT
AS
ST
Influent Efluent
Povratni
mulj
t=5-30 min
10 %
t=2-3 h
30 %
t= 10 -24 h t= 2-5 h
> 90 %
TMELJNI PROCESI PROČIŠĆAVANJA
OTPADNIH VODA
Uklanjanje organskih tvari
C6H12O6 + 6 O2 = 6 CO2 + 6 H2O
APM PT AS ST
Proizvodnja biomase
NH4+ + 1,83 O2 1,98 HCO3
- =
0,021 C5H7NO2 + 0,98 NO3-+ 1,041 H2O + 1,88 H2CO3
Denitrifikacija
2 NO3 + 2H+ = N2(g) + H2O + 5(O)
APM AS N/DN T
Nitrifikacija
HN4+ + 1,5 O2 = NO2
- + H2O + 2 H+ (Nitrosomonas)
NO2 + 0,5 O2 = NO3- (Nitrobakter)
NH4 + 2O2 = NO3- + H2O + 2 H+
KINETIKA BIOLOŠKIH
PROCESA PROČIŠĆAVANJA
OTPADNIH VODA
X
S
X
S
KINETIKA PRIRASTA BIOMSE I POTROŠNJE
SUPSTRATA
kXdt
dXxr
S Ks
ko
ko/2
SK
Skk
s
o
SsK
XSk
dtdX
xr
**0
Monod-ova konstanta brzine reakcije
sYrdtdS
Yxr
)(
**
SsKY
XSok
Y
rsr
x
Xdkdt
dXdr *
XdkSsK
XSok
dtdX
sr ***
BILANCA BIOMASE I SUPSTRATA U SUSTAVU S
AKTIVNIM MULJEM
Q0, S0, X0
V, X, S
AS T
Qr, Xu
Qu, Xu
Q0+ QR, X, S Q0 - Qw, Xe, S
Qw, Xu
Efluent In
Višak mulja
Biomasa
uXwQeXwQoQXdkSK
XSkVoXoQ
s
o
)()(
SwQSwQoQXdkSKY
XSkVoSoQ
s
o
)())(
(
Supstrat
Pretpostavke:
SoS
eX
oX
0
0
Procesi se odvijaju samu u AS !
dkVX
XQ
SK
SK uw
s
o
)( SoSVX
YQ
SK
SK o
s
s
doVX
YQ
VX
XQkSSouw )(
Hidrauličko vrijeme zadržavanja:
oQV
Starost mulja:
uwXQVX
c
Uvrštavanjem i preuređenjem jednadžbi
dobivamo:
X
SSY o
c *
)(1
)1(
)(
cd
oc
k
SSYX
Prostorno opterećenje (VL ili BR):
XY
kSoS
c
cd *1(
)(Xf
V
QSLV o
dm
kgBPK3
5
Muljno opterećenje (F/M ili BTS):
kgSTd
kgBPK5
VX
SSQMF
)(/ 0
UČINAK PROČIŠĆAVANJA OVISNO O
MULJNOM OPTEREĆENJU
0
50
100
0.01 0.1 1 10
)223.0*log956.0(10
)1
*60(100
TSBA
A
A
BTS
/%
TEHNOLOŠKI PARAMETRI UREĐAJA ZA
PROČIŠĆAVANJA OTPADNIH VODA
TIPIČNI VRIJEDNOSTI TEHNOLOŠKIH PARAMETARA
UREĐAJA ZA PROČIŠĆAVNJE OTPADNIH VODA
BTS kg BPk5/kg ST d 0.05 0.15 >1.0
Efikas. % 96 92.5 ~60
ST g/L 5 3.3 2-3
BR kgBPK5/m3d 0.25 0.5 >3.5
t h ~24 2 0.5
OO kgO2/kgBPK5 2 2 ~0.7
f 1.25 1.25 2
P kWh/kg BPK5 1.04 1.08 0.5
Višak
mulja
UREĐAJI ZA PROČIŠĆAVANJE OTPADNIH VODA
POSTUPAK S AKTIVNIM MULJEM
UZ PRIMARNI TALOŽNIK
1. Gruba i fina rešetka (GFR)
2. Aerirani pjeskolov mastolov(APM)
3. Primarna taložnica (PT)
4. Aeracijski spremnik (AS)
5. Sekundarni taložnik (ST)
GFR APM PT
AS
ST
Influent Efluent
Povratni
mulj
t=5-30 min
10 %
t=2-3 h
30 %
t= 10 -24 h t= 2-5 h
> 90 %
UREĐAJI ZA PROČIŠĆAVANJE OTPADNIH VODA
POSTUPAK S AKTIVNIM MULJEM
BEZ PRIMARNE TALOŽNICE
1. Gruba i fina rešetka (GFR)
2. Aerirani pjeskolov mastolov(APM)
3. Aeracijski spremnik (AS)
4. Taložnik (T)
GFR APM
Influent
t=5-30 min
10 %
Višak
mulja
AS
T
Efluent
Povratni
mulj
t= 10 -24 h t= 2-5 h
> 90 %
UKLANJANJE DUŠIKA I FOSFORA
IZ OTPADNIH VODA
SPOJEVI DUŠIKA U OTPADNIM VODAMA
Org-N u mulju: 5.9
mg/L
TN=33.6 mg/L
NO2+3-N
3.0 mg/L
NH4-N
18.4 mg/L
Org-N
12.2 mg/L
NO2+3-N
12.6 mg/L
NH4-N
1.0 mg/L
Org-N
2.3 mg/L
Denitrifikacija
Redukcija Nitrifikacija
Amonifikacija
Precipitacija Asimilacija
N2 15.1 mg/L
POSTUPCI PROČIŠĆAVANJA
Ovisno o primijenjenim procesima pročišćavanja
razlikujemo:
- Pročišćavnja bez nitrifikacije;
- Pročišćavanja uz nitrifikaciju;
- Pročišćavanja uz uklanjanje spojeva dušika, a i fosfora.
Spojevi dušika uklanjanju se postupkom nitrifikacije i denitrifikacije.
Postoji niz različitih reaktorskih sustava za ove procese. Neki od tih su:
- Prethodna denitrifikacija;
- Naknadna denitrifikacija;
- Simultana denitrifikacija;
- Kaskadna denitrifikacija;
- Izmjenična denitrifikacija;
- Denitrifikacija s prekidima, a i drugi.
Prethodna denitrifikacija
Sekundarni
taložnik Denitrifikacija Nitrifikacija
Povrat mulja
Ulaz vode
Efluent
Višak mulja
Interna recirkulacija
Naknadna denitrifikacija
Sekundarni
taložnik Denitrifikacija Nitrifikacija
Povrat mulja
Ulaz vode
Efluent
Višak mulja
Naknadna
aeracija
Simultana denitrifikacija
Sekundarni
taložnik
Denitrifikacija
Nitrifikacija
Povrat mulja
Ulaz vode
Efluent
Višak mulja
Kaskadna denitrifikacija
Sekundarni
taložnik D Nitrifikacija
Povrat mulja
Ulaz vode
Efluent
Višak mulja
Nitrifikacija D
D = Denitrifikacija
Izmjenična denitrifikacija
Sekundarni
taložnik
Nitrifikacija
Povrat mulja
Ulaz vode Efluent
Višak mulja
Denitrifikacija
Denitrifikacija s prekidima
Sekundarni
taložnik
Denitrifikacija
Nitrifikacija
ili
Povrat mulja
Ulaz vode Efluent
Višak mulja
UKLANJANJE SPOJEVA FOSFORA
a) Biološko uklanjanje fosfora
b) Uklanjanje kemijskim postupcima
FeCl3 + PO43- = FePO4 +3 Cl-
Temelji se na procesima adsorpcije i
ugradnje u biomsu.
Fosfor je prisutan u obliku PO43- i Org-P
ULAZNI PODACI ZA DIMENZIONIRANJE
UREĐAJA ZA PROČIŠĆAVANJE
OTPADNIH VODA
KAKVOĆA OTPADNIH VODA
TIPIČNI POKAZATELJI KAKVOĆE
KOMUNALNIH OTPADNIH VODA
Industrijske otpadne vode:
KPK, O2 mg/L 500-10000
Protok, Q, m3/h
Susp. tvar., mg/L 220 30
Vol. susp. tvari., ml/ 10
BPK5, O2, mg/L 220 25
KPK, O2, mg/L 500 125
Tot. N, mg/L 40 10
Org-N, mg/L 15
NH3-N, mg/L 25
NO2-N, mg/L 0
NO3-N, mg/L 0
Tot. P, mg/L 8 2 Org-P, mg/L 3
Anorg-P, mg/L 5
Kloridi, Cl- 50
Alk., CaCO3,, mg/L 100
Masti i ulja, mg/L 100
Pokazatelj kakvoće Koncentracija MDK efluenta
WASTEWATER TREATMEN PLANT BJELOVAR
The values of COD (mg/L O2) at different treatment steps
0
100
200
300
400
500
600
700
800
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Date January 2002
CO
D, m
g/L
O
2
Ulaz
Izlaz A
Izlaz B
WASTEWATER FLOW RATE GAREŠNICA
30.8. - 6.9. 2004.
0.00
0.01
0.01
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.05
30.8. 8:00 31.8. 8:00 1.9. 8:00 2.9. 8:00 3.9. 8:00 4.9. 8:00 5.9. 8:00 6.9. 8:00
Time/ day
Q / m
3/s
Dnevne varijacije protoka otpadnih voda
0
100
200
300
400
500
600
0 2 4 6 8 10 12 14 16 18 20 22 24
Sati
Pro
tok
/m3
/h
Dnevni prosjek
Maksimalni satni protok
ULAZNI PODACI ZA DIMENZIONIRANJE
UREĐAJA ZA PROČIŠĆAVNJE OTPADNIH
VODA
PROTOK VODE
EKVIVALENTI STANOVNIKA (ES)
Broj stanovnika
Protok vode L/(ES*dan)
<5000
150
5000 – 10000
180
10000 – 50000
220
50000 – 250000
250
>250000
300
PODACI NA TEMELJU TERENSKIH MJERENJA
Dnevne količine otpadnih voda – sušno razdoblje:
Qd - Prosječni dnevni protok
QT,d - Prosječni dnevni protok – sušno razdoblje
QT,h,max - Maksimalni satni protok – sušno razdoblje
Sušni protok:
Qt = QT,d
Kišni protok:
QW = 2* Qt
OPTEREĆENJE OTPADNIH VODA
EKVIVALENTI STANOVNIKA
BPK5 60 g/(ES*d)
KPK 120 g/(ES*d)
ST 70 g/(ES*d)
N 12 g/(ES*d)
P 3 g/(ES*d)
MJERENJE PROTOKA OTPADNIH
VODA U KANALIZACIJSKOJ
MREŽI
Shematski prikaz pregradne ploče za mjerenja protoka otpadne vode.
Dimenzije su u mm.
ghlhQ 2
Q = protok m3/s
L = širina toka, m
h = visina toka, m
g = 9,81 m/s2
PRAVOKUTNI PRELJEV ZA MJERENJE
PROTOKA OTPADNE VODE
Mjerni profil s ultrazvučnim mjeračem razine na glavnom kolektoru otpadnih voda u Đakovu
Lokacija uzorkovanja na glavnom kolektoru otpadnih voda grada Đakova
Mjerni kanal s instaliranim mjeračem razina na izlazu uređaja za pročišćavanje
otpadnih voda grada Križevaca
MJERENJA PROTOKA OTPADNIH
VODA
Mjerenje protoka otpadnih voda
ultrazvučnom sondom primjenjujući
Doppler-ov efekt.
V
h
Area-Velocity Flow Meter
AVFM
UZIMANJE UZORAKA
OTPADNIH VODA
SHEMATSKI PRIKA AUTOMATSKOG
UZORKIVAČA OTPADNIH VODA
Vacuum Tlak
Spremnik
za uzorak
Kanal
Automatski uzorkivač na ulazu uređaja za pročišćavanje otpadnih voda grada Križevaca
NOVI TRENDOVI U RAZVOJU POSTUPAKA
PROČIŠĆAVNJA OTPADNIH VODA
PRIMJENA MEMBRANSKIH TEHNOLOGIJA
Koncentracija biomase biomase 3 – 5 g/L
APM AS N/DN T
Membranska filtracija
APM AS N/DN F
0
200
400
600
800
1.000
1.200
1.400
1.600
1.800
0 2 4 6 8 10 12 14 16
Koncentracija mulja [kg/m3]
Vo
lum
en
bazen
a [
m3]
V= f(X)
Koncentracija biomase 12 – 15 g/L
APM AS N/DN F
F
APM AS N/DN T
Koncentracija biomase biomase 3 – 5 g/L
Spektar filtracije
0.0001 0.001 0.01 0.1 1 10 100m
hair Crypto-
sporidium
smallest
micro-
organism
polio
virus
Suspended solids
Parasites
Bacteria
Org. macro. molecules
Viruses
Colloids Dissolved salts
Sand filtration
Microfiltration
Ultrafiltration
Nanofiltration
Reverse Osmosis
ZW® - Shematski prikaz vlakna
Membrana
Veliki mjehuri
Difuzor Veliki mjehuri
Difuzor
Nosivi sloj
Filtrat prema gornjem kolektoru
Filtrat prema donjem kolektoru
Biomasa
Aeracija Mjehuri
(za mješanje fluida)
Membrane sa
šupljim vlaknima Pločaste membrane
ZeeWeed® ZW500 membrane sa
šupljim vlaknima
6 m Zeno Okvir sa 6 Kaseta - 48 modula
1 Kaseta sa 8 ZeeWeed modula
484 m2 površine filtracije
12 m Zeno Okvir sa 12 Kaseta - 96 modula
Dijagram toka
Filtrat
Uronjene
membrane
Čišćenje/Otpad
Bazen sa
membranama
Pumpa filtrata
Spremnik za
protustrujno
ispiranje
Dotok vode koja
se pročišćava
ZenoGem® MBR Shema
Otpadni mulj @1.5%-2.0%
Tretirana voda
ZeeWeed Membranski Bioreaktor
Backpulse spremnik
Fino sito
Spremnik aditiva
Puhala
1. Ulazna graðevina
2. Kišna retencija
3. Upravna zgrada
4. Pjeskolov
5. Prvi biološki stupanj
6. Aeracijski spremnik
7. Taložnici
8. Laguna za mulj Proèišæena
voda
Ispust
UREÐAJ ZA PROÈIŠÆAVANJE OTPADNIH VODA GRADA
BJELOVARA
Slika 3. Varijanta 1a Stanje 2003. godine
1
2
3
4
5 6
7
8 Mulj
1. Ulazna graðevina9. Novi aeracijski spremnik
2. Kišna retencija10. Novi taložnik
3. Upravna zgrada
4. Pjeskolov
5. Prvi biološki stupanj
6. Aeracijski spremnik
7.Taložnici
8. Laguna za mulj
Proèišæena voda
Ispust
UREÐAJ ZA PROÈIŠÆAVANJE OTPADNIH VODA GRADA BJELOVARA
Slika 5. Varijanta 2b i 2c
1
2
3
4
5
6
7
8
Mulj
9 9 10 19
1. Ulazna graðevina
2. Kišna retencija
3. Upravna zgrada
4. Pjeskolov
5. Prvi biološki stupanj
6. Aeracijski spremnik
7. Taložnici
8. Laguna za mulj
Proèišæena
voda
Ispust
UREÐAJ ZA PROÈIŠÆAVANJE OTPADNIH VODA GRADA
BJELOVARA
Slika 7. Varijanta 2d
1
2
3
4
5 6
7
8 Mulj
KRAJ