Uputstvo za rad OLC 10 OLCT 10
Analogni gas detektor
Ref: NP010SRB revizija: G
_________________________________________________________________________________________ 1
Copyright 2010 by Oldham S.A.S All rights reserved. No reproduction of all or part of this document, in any form, is permitted without the written consent of Oldham S.A.S. All of the information that is provided in this document is accurate to the best of our knowledge. As a result of continuous research and development, the specifications of this product may be changed without prior notice. Oldham S.A.S Rue Orfila
Z.I. Est – CS 20417 F–62027 ARRAS Cedex Tel.: +33 (0)3 21 60 80 80 Fax: +33 (0)3 21 60 80 00 Ovlašćeni predstavnik u Srbiji:
SVECOM d.o.o Ustanička 128a / III 11000 Beograd tel.: +381 (0) 11 34 74 210 faks: +381 (0) 11 30 45 507 www.gasdetekcija.rs
_________________________________________________________________________________________ 2
Hvala što ste izabrali OLDHAM instrument.
Sve neophodne akcije su preduzete da bi obezbedili vašu potpunu satisfakciju sa ovom opremom.
Bitno je da pročitate ovo uputstvo potpuno i pažljivo.
Granica Vaše odgovornosti
OLDHAM ne preuzima odgovornost, ni prema kome, u pogledu materijalnih šteta, fizičkih povreda ili smrtnih ishoda koje su nastale delimičnom ili kompletnom neodgovarajućom upotrebom, instalacijom ili skladištenjem naše opreme koje su nastale usled nepoštovanja iznetih uputstava i upozorenja i/ili standarda i propisa koji su na snazi.
OLDHAM ne garantuje za, niti ovlašćuje bilo koju firmu niti fizičko ili pravno lice, da
preuzme odgovornost u ime OLDHAM-a, čak i ako oni učestvuju u prodaji OLDHAM-ovih proizvoda
OLDHAM se ne može smatrati odgovornim za direktnu ili indirektnu štetu ili da se od nas
zahteva direktna ili indirektna odšteta na ime kupovine ili upotrebe bilo kojeg od naših proizvoda AKO OVI PROIZVODI NISU DEFINISANI I IZABRANI OD STRANE OLDHAM-a ZA NjIHOVU SPECIFIČNU UPOTREBU.
Deo koji se odnosi na imovinu
Crteži, planovi, specifikacije i informacije koje se nalaze u ovom dokumentu sadrže poverljive informacije koje su vlasništvo OLDHAM-a.
Nijedna od ovih informacija se ne može reprodukovati, kopirati, objavljivati ili prevoditi, fizičkim, elektronskim ili bilo kojim drugim sredstvima, niti koristiti kao osnova, za proizvodnju ili prodaju OLDHAM opreme ili iz bilo kog drugog razloga bez prethodnog pristanka od strane OLDHAM-a.
Upozorenja
Ovaj dokument nije ugovorno obavezujuć. U interesu svojih korisnika, OLDHAM zadržava pravo modifikacije tehničkih specifikacija svoje opreme bez prethodnog obaveštenja, kako bi se performanse uređaja mogle poboljšavati.
PROČITAJTE OVO UPUTSTVO PAŽLjIVO PRE PRVE UPOTREBE OPREME: ovo uputstvo moraju pročitati sve osobe koje će biti odgovorne za upotrebu i održavanje.
Ova oprema će pružiti navedene nivoe performansi, samo ako se ista koristi, održava i popravlja u skladu sa uputstvima OLDHAM-a, od strane OLDHAM-ovog osoblja ili od strane osoblja koje je ovlastio OLDHAM.
Garancija
U normalnim uslovima upotrebe, na delove i tehničke popravke, kada se pošalju u naše servise, garancija je 2 godine, ne računajući potrošne delove (senzore, filtere, itd.)
_________________________________________________________________________________________ 3
_________________________________________________________________________________________ 4
SADRŽAJ
I PREDSTAVLjANjE RAZLIČITIH VERZIJA 6
II MEHANIČKA INSTALACIJA RAZLIČITIH VERZIJA, DIMENZIJE I POSTAVLjANjE
6
III ELEKTRIČNA INSTALACIJA RAZLIČITIH VERZIJA 8 1. Dijagram povezivanja OLC10 ili OLCT10 na centralnu jedinicu
za detekciju zapaljivih gasova 8
2. Dijagram povezivanja između dva OLC10 TWIN (eksplo) na kontrolnu jedinicu
9
3. Dijagram povezivanja dva OLCT10 TOX (maksimum 5) na kontrolnu jedinicu za detekciju otrovnih gasova
10
4. Dijagram povezivanja dva OLCT10 TOX mreže, za detekciju dva različita otrovna gasa ili monitoring dva povezana prostora na dva kanala kontrolne jedinice
11
IV ODRŽAVANjE 12 1. Periodično održavanje OLC10 detektora (eksplo gas) 12
2. Periodično održavanje OLC10 TWIN transmitera ( eksplo gas)
12
3. Periodično održavanje OLCT10 transmitera (eksplo ili otrovni gas)
13
4. Periodično održavanje sa nekoliko OLCT10 transmitera za otrovne gasove
14
5. Zamena ćelije 14
6. Odlaganje 14
V TEHNIČKE SPECIFIKACIJE 16 1. Tehničke specifikacije – OLC10/OLC10 Twin senzor 16
2. Tehničke specifikacije – OLC10 Eksplo transmiter 17
3. Tehničke specifikacije – OLC10 CO transmiter 18
4. Tehničke specifikacije – OLC10 SC transmiter 19
5. Tehničke specifikacije – OLCT10 NO transmiter 20
6. Tehničke specifikacije – OLCT10 NO2 transmiter 21
VI Detaljna specifikacija za korišćenje u eksplozivnoj atmosferi u skladu sa ATEX 94/9/CE Evropskom Direktivom
22
1. Specifikacija za mehaničku i električnu instalaciju u ATEX Zoni 2 klasifikovanog prostora
22
2. Metrološka specifikacija za OLC10 eks. detektore 22
2.1 Specijalne mere 22
2.2 Rakcija na druge eksplozivne gasove 22
3. Označavanje 23
VII DEKLARACIJA O USAGLAŠENOSTI 24
_________________________________________________________________________________________ 5
_________________________________________________________________________________________ 6
II .. PPRREEDDSSTTAAVVLLjjAANNjjEE RRAAZZLLIIČČIITTIIHH VVEERRZZIIJJAA
OLC10, OLC10 Twin i OLCT10 EXPLO detektori-transmiteri su detektori sa katalitičkim ćelijama posebno dizajnirani za upotrebu u prostorijama kotlarnica i parking mesta.
OLCT10 TOX gas detektori sa prenosom od 4-20mA, opremljeni sa elektrohemijskom ćelijom i posebno dizajnirani za detekciju otrovnih gasova u komercijalnom i lako industrijskom okruženju (parking mesta, prostorije kotlarnica, i td).
RRaazzlliiččiittee rraassppoolloožžiivvee vveerrzziijjee
- OLC10: zapaljivi gas - OLC10 TWIN: zapaljivi gas - OLCT10 EXPLO: eksplozivni gas (transmiter verzija, izlaz 4-20 mA) - OLCT10 TOX: otrovni gasovi (transmiter verzija, izlaz 4-20 mA)
IIII .. MMEEHHAANNIIČČKKAA IINNSSTTAALLAACCIIJJAA,, DDIIMMEENNZZIIJJEE II PPOOSSTTAAVVLLjjAANNjjEE
OLC/OLCT10 gas detektori-transmiteri se montiraju vertikalno sa kablovskim ulazom pozicioniranim nadole.
Izbušite dve rupe na rastojanju 104 mm na osnovi jedinice za montažu.
_________________________________________________________________________________________ 7
_________________________________________________________________________________________ 8
IIIIII .. EELLEEKKTTRRIIČČNNAA IINNSSTTAALLAACCIIJJAA RRAAZZLLIIČČIITTIIHH VVEERRZZIIJJAA
11.. PPoovveezziivvaannjjee OOLLCC1100,, OOLLCCTT1100 EExxpplloo iillii OOLLCCTT1100 SSCC ((ppoolluupprroovvooddnniiččkkii)) nnaa kkoonnttrroolleerr zzaa ddeetteekkcciijjuu zzaappaalllljjiivvoossttii
Napomene:
- Konfiguracija centrale će biti različito u zavisnosti od upotrebe OLC10 ili OLCT10.
- Kabl koji treba koristiti: sa 3 provodnika tip LiY-CY 3x1mm²
npr., Centrala MX15
Povežite3 i žile na odgovarajuće brojeve senzora
* analogni signal 4-20 mA (I out) na OLCT10
Povežite 3 žile na odgovarajuće brojeve kontrolera
_________________________________________________________________________________________ 9
22.. PPoovveezziivvaannjjee ddvvaa OOLLCCTT1100 TTwwiinn nnaa kkoonnttrroolleerr
Kabl koji treba koristiti: sa 3 i 4 žile, tip LiY-CY 3x1mm² i 4x1mm²
Povežite 3 žile na odgovarajuće brojeve kontrolera
senzora
Povežite 4 žile na odgovarajući broj predhodnog i narednog senzora Povežite 3 žile na odgovarajući broj prvog
_________________________________________________________________________________________ 10
33.. PPoovveezziivvaannjjee ddvvaa OOLLCCTT1100 TTooxx ((mmaakkssiimmaallnnoo 55)) nnaa kkoonnttoolleerr
Kabl koji treba koristiti: jedna parica (0.75 mm2) oklopljeni kabl
Napomena: slobodni terminali omogućuju povezivanje drugih mreža OLCT 10 TOX.
KOMENTARI:
- broj OLCT 10 TOX detektora će biti konfigurisan na kontroleru,
- očitan signal na kontroleru je prosečna vrednost “n” detektora. Kao rezultat ovoga, signal greške ne može da bude detektovan. U slučaju da se koriste dve mreže, ekonomičnije je da se koristi jedan kabl sa dve parice, u skladu sa električnim zahtevima u nastavku.
Povežite 2 žile na odgovarajuće brojeve MX15 kontroler kontrolera
na odgovarajući broj prvog senzora sledećeg senzora
Povežite 2 žile na Povežite 2 žile na odgovarajući broj
_________________________________________________________________________________________ 11
44.. PPoovveezziivvaannjjee ddvvee OOLLCCTT1100 TTooxx mmrreežžee ((mmaakkssiimmaallnnoo 55 sseennzzoorraa)) zzaa ddeetteekkcciijjuu ddvvaa rraazzlliiččiittaa oottrroovvnnaa ggaassaa iillii nnaaddgglleeddaannjjee ddvvaa ppoovveezzaannaa pprroossttoorraa nnaa ddvvoo kkaannaallnnoomm kkoonnttoolleerruu
Kabl koji se koristi: dvo parični kabl (0.75mm2)
Primer, jedna zona dva gasa
Detektor 1 Detektor 2 Detektor 3 Detektor 4
kabl sa 4 žile
Centralna jedinica sa minimalno 2 kanala
Informacije u ovom slučaju:
- kanal 1 je kanal na koji su povezana dva senzora za detekciju CO,
- kanal 2 je kanal na koji su povezana dva senzora za detekciju NO,
- Senzor 1 (CO) takođe služi kao razvodna kutija za detektor 2 (NO)
- Senzor 2 (NO) takođe služi kao razvodna kutija za detektor 3 (CO)
- Senzor 3 (NO) takođe služi kao razvodna kutija za detektor 4 (NO)
Kanal 1 Kanal 2
_________________________________________________________________________________________ 12
IIVV OODDRRŽŽAAVVAANNjjEE
Upozorenje: Radnje objašnjene u ovom odeljku su namenjene autorizovanom i uvežbanom pojedincu koji se pretežno bavi pitanjima bezbedne detekcije.
Detektori gasa su bezbedonosni uređaji. Prepoznajući ovu činjenicu, OLDHAM preporučuje sprovođenje funkcionalnog “ bump testa “ za svaki stacionarni instrument za detekciju gasa kao deo redovnog programa održavanja. Funkcionalni test je definisan kao kratko izlaganje detektora koncentraciji gasa koja premašuje najnižu alarmnu tačku senzora u cilju verifikacije senzora i rada alarma i nije zamena provere tačnosti merenja instrumenta. Učestalost ovakvog testiranja gasom zavisi od industrijskog okruženja u kome se detektori koriste, izloženosti gasu, tehnologiji senzora. Ispitivanja treba izvršiti mesec dana nakon puštanja u rad instalacije, a nakon toga period može da se poveća u slučaju da nisu uočena značajnija odstupanja. Interval između dva testa ne bi trebalo da prelazi 3 meseca.
Ako detektor ne reaguje zadovoljavajuće na gas, neophodna je kalibracija detektora. Učestanost kalibracije određuje se prema rezultatima testa (vlažnost, temperatura, prašina i td); međutim taj vremenski interval ne bi trebalo da bude duži od jedne godine.
Ove preporuke se baziraju na procedurama za bezbednost u radu, najboljoj industrijskoj praski i standardima kojis eodnose na bezbednost u radu. Oldham nije odgovoran za sprovodjenje bezbedonosnih procedura.
11.. PPeerriiooddiiččnnoo ooddrržžaavvaannjjee OOLLCC 1100 ddeetteekkttoorraa
- Pozicija “održavanja” je izabrana na kontrolnoj jedinici, relei su onesposobljeni (pogledaj uputstvo za odgovarajući proizvod)
Opomena: budite sigurni da imate čist vazduh, u protivnom dovideti sintetisan čist vazduh na senzor (pomoću kalibracionog kita) sa protokom od 60L/h, tada sačekajte stabilizaciju merenja.
- Izvršite podešavanje nule na kontrolnoj jedinici (pogledaj uputstvo za odgovarajući proizvod)
- Sada dvedite kalibracioni gas (60L/h) na senzor OLC10 i sačekajte stabilizaciju signala na displeju kontrolne jedinice
- Ukoliko je neophodno, kalibrišite osetljivost pomoću “S” potenciometra na centralnoj jedinici (pogledaj uputstvo za odgovarajući proizvod)
- Nakon završetka kalibracije: sačekajte “vraćanje na nulu” na displeju centralne jedinice
- Povratak u “normalan” režim na centralnoj jedinici (pogledaj uputstvo za odgovarajući proizvod)
22.. PPeerriiooddiiččnnoo ooddrržžaavvaannjjee OOLLCC 1100 TTwwiinn ddeetteekkttoorraa
- Procedura je skoro identična poziciji 1 (standardni OLC10), sa izuzetkom podešavanja osetljivosti koja se izvodi na OLCT 10 Twin detektoru koji je manje osetljiv.
- Da bi odredili detektor sa manjom osteljivošću, dovedite gas na oba detektora, prvo na jedan a onda na drugi ( sačekajte da se stabilizuje očitavanje nule). Detektor koji ma manje očitavanje ima manju osetljivost.
_________________________________________________________________________________________ 13
33.. PPeerriiooddiiččnnoo ooddrržžaavvaannjjee OOLLCCTT 1100 ttrraannssmmiitteerraa ((eekksspplloo iillii ttookkss..))
- Koristite kit koji je obezbedio Oldham ( refernca 6 147 872 )
- Uklonite završni poklopac koji obezbeđuje pristup podešavanju, lociran na desnoj strani ćelije
- Povežite kit na muški konektor na ploči, kako je prikazano ispod:
potenciometar NULE (4mA) potenciometar OSETETLJ.( 20mA)
KONEKTOR ODRŽAVANJA ŽICE:
- +V DC/crvena = napajanje - -4 do 20 mA/plava = - napon , prikaz 4 do 20 mA - +4 do 20 mA/zelena = + napon, prikaz 4 do 20 mA - S signal/žuta = signal 0mV do 1600 mV za podešavanje nule i osetljivosti - Ref 2.5V/siva = referenca 0 za očitavanje signala 0 mV do 1600 mV - GND/crna = masa elketričnog kola
- Prebacie chnager-over (sa povezanim) u “Cal” poziciju (desno).
Upozorenje: nakon 9 minuta transmiter se automatski vraća u normalni režim rada ( jedino verzija OLCT10 explo)
Napomena: budite sigurni da imate čist vazduh, u protivnom dovedite čist vazduh na senzor (pomoću kalibracionog kita) sa protokom od 60L/h, pa sačekajte stabilizaciju merenja na volt metru.
- Podesite NULU potenciometrom za nulu do očitavanja 0 mV na voltmetru
- Zatim ubrizgajte standardni gas (60 L/h) na ćeliju, sačekajte stabilizaciju signala na voltmetru
- Ukoliko je potrebno, podesite osetljivost “S” potenciometrom do očitavanja 1.600 mV za pun opseg skale (odgovara 20 mA)
- Zaustavite ubrizgavanje gasa (uklonite kalibracioni dodatak)
- Sačekajte povratak na vrednost nule na voltmetru
- Vratiti preklopnik chnager-over održavanja u normalnu poziciju (na levo)
_________________________________________________________________________________________ 14
Napomene za OLCT10 verziju za eksplozivne gasove:
- transmiter kontroliše „dvosmislenu rezoluciju“: ako senzor detektuje koncentraciju gasa preko 100% LEL (20 mA), signal će biti zaključan na 23.2 mA, ovo se potvrđuje isključivanje napajanja ili prebacivanjem prekidača održavanja. Dvosmislena rezolucija može biti automatski potvrđena ukoliko tačke PPS3 budu kratko spojene.
- Nakon uključivanja, izlazni signal je podešen na 2 mA u trakanju 60 sekundi stabilizacionog vremena.
44.. PPeerriiooddiiččnnoo ooddrržžaavvaannjjee ssaa nneekkoolliikkoo ttookk.. OOLLCCTT 1100 ttrraannssmmiitteerraa
Koristite proceduru objašnjenu u predhodnim paragrafima. Međutim:
- Startujte sa poslednjim transmiterom u petlji u odnosu na centralnu jedinicu
- Kalibrišite svaki transmiter u petlji i završite sa prvim.
55.. ZZaammeennaa sseennzzoorraa
Zamena ćelije je rezultat nemogućnosti kalibracije ili kao preventivna mera. Izvedite novu kalibraciju nakon zamene ćelije (pogledaj odeljak IV).
66.. OOddllaaggaannjjee
Za očuvanje, zaštitu i unapređenje kvaliteta životne sredine i za zaštitu zdravlja i mudro i racionalno korišćenje prirodnih resursa, OLCT 10 mora da bude uklonjen odvojeno kao elektronski otpad i ne može da budu uklonjeni sa kućnim otpadoma. Korisnik mora stoga da odvoji OLCT 10 od ostalog otpada da bi se reciklirao bezbedno za okolinu. Za više detalja o postojećim lokacijama, kontaktirajte lokalnu samoupravu ili prodavca opreme.
_________________________________________________________________________________________ 15
_________________________________________________________________________________________ 16
IIVV TTEEHHNNIIČČKKEE SSPPEECCIIFFIIKKAACCIIJJEE
11.. TTeehhnniiččkkee ssppeecciiffiikkaacciijjee OOLLCC 1100 // OOLLCC 1100 TTwwiinn
Detektor eksplozivnih gasova
Detekcioni princip Katalitički
Opseg 0 – 100% LEL metana, propana ili butana
Izlazni signal Wheastone mosno kolo
Napajanje Strujno preko MX15 centralne jedinice
Povezivanje OLC 10 verzija - 3 žični terminal, maksimalno rastojanje 300m i 1,5mm2 sa
centralnom jedinicom MX15 - 1 kablovski uvodnik M16: prečnik kabla 4 do 8 mm
OLC 10 Twin - jedan 3 žični terminal blok na centralnoj jedinici - jedan 4 žični terminal blok za sekundarni senzor - maksimalno ukupno rastojanje 300m i 1,5mm2 sa mX15 - dva kablovska uvodnika M16: prečnik kabla 4 do 8mm
Dimenzije Širina 118mm, Visina 157mm, Dubina 60mm
Materijal Plastika
Zaptivenost IP 66
Skladištenje 6 meseci bezbedno na vazduhu -10°C<T<35°C +10%<RH<60%
Preporučeni vek Veći od 36 meseci
Temperaturni opseg -10°C do + 45°C
Opseg vlažnosti 0% RH do 95% RH
Opseg pritiska 1bar ± 20%
Linearnost za opseg 0 do 70% LEL ≤ 1% LEL CH4 za opseg 70 do 100% LEL ≤ 7% LEL CH4
Dugoročni pomeraj merenja pod normalnim radnim uslovima
Nula < 10% LEL / godišnje Osetljivost < 20% merne vrednosti godišnje
Uticaj vlažnosto ± 5% ralativne osetljivosti
Vreme odziva T50<10 sekundi, T90<20 sekundi
Sertifikati Elektro magnetna kompatibilnost EN 50270
Eksplozivna atmosfera: II3 G / EEx nA IIC T6
_________________________________________________________________________________________ 17
22.. TTeehhnniiččkkee ssppeecciiffiikkaacciijjee OOLLCCTT 1100 eekksspplloo ttrraannssmmiitteerr
Transmiter eksplozivnih gasova
Detekcioni princip Katalitički Opseg 0 – 100% LEL metana, propana ili butana
Izlazni signal 4-20mA, standardno ≤ 0.5mA ili ≥ 23.2mA
Dvoznačna rezolucija Zaključano na 23.2mA ukoliko je merenje ≥ 100% LEL , brisanje gašenjem i paljenjem dvoznačna rezolucija transmitera se može ukloniti prespajanjem tačaka za programiranje
Podešavanje: Lokalno preko potenciometra za Nulu i Osetljivost Pozicija Održavanja 2mA 6 to pini konektor za merenje gasa i strujnog prikaza ( 100Ω šant)
Napajanje 15 do 30V DC Potrošnja: Maksimalno 100mA Dužina kabla U zavisnosti od kontrolera Opterećenje 300Ω Povezivanje 3 žični terminal blok, 2 žice za napajanje, 1 žica za signal
kablovski uvodnik M16: prečnik kabla 4 do 8mm
Dimenzije Širina 118mm, visina 157mm, dubina 60mm Materijal Plastika Zaštita IP66 Lagerovanje 0°C<T<35°C
Preporučeni vek Veći od 36 meseci Temperaturni opseg -10°C do + 40°C Opseg vlažnosti 0% RH do 95% RH Opseg pritiska 1bar ± 20% Linearnost za opseg 0 do 70% LEL ≤ 1% LEL CH4
za opseg 70 do 100% LEL ≤ 7% LEL CH4 Temperaturni pomeraj (-10°C + 40°C)
< ± 5% LEL Methane ili < 20% indikacije
Dugoročni pomeraj merenja pod normalnim radnim uslovima
Nula < 10% LEL / godišnje Osetljivost < 20% merne vrednosti godišnje
Uticaj vlažnosti ( 10 do 90% RH) na 40°C
± 5% ralativne osetljivosti
Vreme odziva T50<10 sekundi, T90<20 sekundi
Sertifikati: Elektro magnetna kompatibilnost EN 50270
Eksplozivna atmosfera: II3 G / EEx nA IIC T4
_________________________________________________________________________________________ 18
33.. TTeehhnniiččkkee ssppeecciiffiikkaacciijjee OOLLCCTT 1100 CCOO ttrraannssmmiitteerr
Detekcioni princip Elektro hemijska ćelija
Opseg 0 – 300ppm CO
Signalni izlaz 4-20mA Podešavanje: Lokalno preko potenciometara za Nulu i Osetljivost
Pozicija održavanja 2mA 6 to pini konektro za merenje gasa i strujnog prikaza
( 100Ω šant)
Napajanje: 15 do 30V DC Potrošnja: maksimalno 30mA Dužina kabla U zavisnosti od kontrolera Povezivanje: 1 terminal blok sa 2 ulazne žice, 1 terminal blok sa 2 izlazne
žice.
Ukoliko je kabl sa gas signalnim parom: 1 terminal blok sa 2 ulazne žice sa kopiranjem na 1 terminal sa 2 žice
Dva kablovska uvodnika M16:prečnik kabla 4 do 8mm
Dimenzije Širina 118mm, visina 157mm, dubina 60mm Materijal Plastika Zaptivenost IP66
Lagerovanje 6 meseci bezbedno na vazduhu -10°C<T<35°C +10%<RH<60%
Preporučeni vek Veći od 36 meseci Temperaturni opseg -10°C do + 45°C Opseg vlažnosti 15% RH do 90% RH Opseg pritiska 1bar ± 20% Linearnost 0-100 ppm ±3ppm
100-1000ppm ±4% relativno
Temperaturni pomeraj (-10°C + 40°C)
±5ppm ili < 5 % indikacije
Dugoročni pomeraj vrednosti pod normalnim radnim uslovima
Osetljivost < 10% merne vrednosti godišnje
Vreme odziva T50<15 sekundi, T90<30 sekundi
Sertifikati: Elektro magnetna kompatibilnost EN 50270
Eksplozivna atmosfera: II3 G / EEx nA IIC T4
_________________________________________________________________________________________ 19
44.. TTeehhnniiččkkee ssppeecciiffiikkaacciijjee OOLLCCTT 1100 SSCC ttrraannssmmiitteerr
Detekcioni princip Poluprovodnički senzor
Opseg 0 – 2000ppm R134A, R22
Signalni izlaz 4-20mA Podešavanje: Lokalno preko potenciometara za Nulu i Osetljivost
Pozicija održavanja 2mA 4 ro pini konektro za merenje gasa i strujnog prikaza
( 100Ω šant)
Napajanje: 15 do 30V DC Potrošnja: maksimalno 100mA Dužina kabla: U zavisnosti od kontrolera Povezivanje: 3 terminal blok, 2 žice napajanja, 1 žica signal.
Jedan kablovski uvodnik M16: prečnik kabla 4 do 8mm
Dimenzije Širina 118mm, visina 157mm, dubina 60mm Materijal Plastika Zaptivenost IP66 Lagerovanje 6 meseci bezbedno na vazduhu -10°C<T<35°C
+10%<RH<60% Preporučeni vek Veći od 24 meseci Temperaturni opseg -10°C do + 60°C Opseg vlažnosti 20% RH do 90% RH Opseg pritiska 1bar ± 20%
Linearnost 0-10ppm ±3ppm 10-30ppm ±5% relativno
Temperaturni pomeraj (-10°C + 40°C)
<±0.4ppm ili < 20 % indikacije
Dugoročni pomeraj vrednosti pod normalnim radnim uslovima
Osetljivost < 20% merne vrednosti godišnje
Vreme odziva T50<51s (R22)
T50<30s (R134A)
Minimalni prag osetljivos. 10ppm Makismalni prag osetljiv. 5000ppm u trajanju od 90s bez gubljenja osetljivosti Preporučeni alarmni prag 200ppm Minimalno vreme za detekciju minimalne koncentracije
Manje od 25s nakon dovođenja 500ppm R134A
Vreme oporavka Manje od 160s nakon dovođenja 1000ppm R134A 8 minuta
Sertifikati: Elektro magnetna kompatibilnost EN 50270 U skladu sa EN 14624 sertifikacijom
_________________________________________________________________________________________ 20
55.. TTeehhnniiččkkee ssppeecciiffiikkaacciijjee OOLLCCTT 1100 NNOO ttrraannssmmiitteerr
Detekcioni princip Elektro hemijska ćelija
Opseg 0 – 100ppm NO
Signalni izlaz 4-20mA Podešavanje: Lokalno preko potenciometara za Nulu i Osetljivost
Pozicija održavanja 2mA 4 ro pini konektro za merenje gasa i strujnog prikaza
( 100Ω šant)
Napajanje: 15 do 30V DC Potrošnja: maksimalno 30mA Dužina kabla: U zavisnosti od kontrolera Povezivanje: 1 terminal blok sa 2 ulazne žice, 1 terminal blok sa 2 izlazne
žice.
Ukoliko je kabl sa gas signalnim parom: 1 terminal blok sa 2 ulazne žice sa kopiranjem na 1 terminal sa 2 žice
Dva kablovska uvodnika M16:prečnik kabla 4 do 8mm
Dimenzije Širina 118mm, visina 157mm, dubina 60mm Materijal Plastika Zaptivenost IP66 Lagerovanje 6 meseci bezbedno na vazduhu -10°C<T<35°C
+10%<RH<60% Preporučeni vek Veći od 36 meseci Temperaturni opseg -10°C do + 45°C Opseg vlažnosti 15% RH do 90% RH Opseg pritiska 1bar ± 20%
Linearnost 0-10ppm ±3ppm 10-100ppm ±5% relativno
Temperaturni pomeraj (-10°C + 40°C)
<±10ppm ili < 10 % indikacije
Dugoročni pomeraj vrednosti pod normalnim radnim uslovima
Osetljivost < 20% merne vrednosti godišnje
Vreme odziva T90<120 sekundi
Sertifikati: Elektro magnetna kompatibilnost EN 50270
Eksplozivna atmosfera: II3 G / EEx nA IIC T4
_________________________________________________________________________________________ 21
66.. TTeehhnniiččkkee ssppeecciiffiikkaacciijjee OOLLCCTT 1100 NNOO22 ttrraannssmmiitteerr
Detekcioni princip Elektro hemijska ćelija
Opseg 0 – 30ppm NO2 Signalni izlaz 4-20mA Podešavanje: Lokalno preko potenciometara za Nulu i Osetljivost
Pozicija održavanja 2mA 4 ro pini konektro za merenje gasa i strujnog prikaza
( 100Ω šant)
Napajanje: 15 do 30V DC Potrošnja: maksimalno 30mA Dužina kabla U skladu sa kontrolerom Povezivanje: 1 terminal blok sa 2 ulazne žice, 1 terminal blok sa 2 izlazne
žice.
Ukoliko je kabl sa gas signalnim parom: 1 terminal blok sa 2 ulazne žice sa kopiranjem na 1 terminal sa 2 žice
Dva kablovska uvodnika M16:prečnik kabla 4 do 8mm
Dimenzije Širina 118mm, visina 157mm, dubina 60mm Materijal Plastika Zaštita IP66 Lagerovanje 6 meseci bezbedno na vazduhu -10°C<T<35°C
+10%<RH<60% Preporučeni vek Veći od 24 meseci Temperaturni opseg -10°C do + 50°C Opseg vlažnosti 15% RH do 90% RH Opseg pritiska 1bar ± 20%
Linearnost 0-10ppm ±0.3ppm 10-30ppm ±5% relativno
Temperaturni pomeraj (-10°C + 40°C)
<±0.4ppm ili < 20 % indikacije
Dugoročni pomeraj vrednosti pod normalnim radnim uslovima
Osetljivost < 20% merne vrednosti godišnje
Vreme odziva T90<60 sekundi
Sertifikati: Elektro magnetna kompatibilnost EN 50270
Eksplozivna atmosfera: II3 G / EEx nA IIC T4
_________________________________________________________________________________________ 22
VV II DETALjNE SPECIFIKACIJE ZA KORIŠĆENjE U EKSPLOZIVNOJ ATMOSFERI U SKLADU SA ATEX 94/9/CE EVROPSKOM DIREKTIVOM
OLC 10 senzor je usklađen sa zahtevima ATEX 94/9/CE Evropske Direktive u pogledu
eksplozivne atmosfere.
Upravnik pogona na kome je oprema instalirana treba uzeti u obzir i raditi u skladu sa informacijama u sledećim paragrafima. Konsultovati odredbe ATEX 1999/92/CE Evropske Direktive koje se tiču povečanaj bezbednosti i zdravlja radnika izloženih rizicima eksplozivne atmosfere.
11.. SSppeecciiffiikkaacciijjaa zzaa mmeehhaanniiččkkee ii eelleekkttrriiččnnee iissnnttaallaacciijjee uu AATTEEXX ZZoonnii 22 kkllaassiiffiikkoovvaannoomm pprroossttoorruu
Instalacija treba da bude izvedena u skladu sa postojećim standardima, u pojedinostima sa EN 600079-14 i EN 60079-17 standardima.
Detektor je dizajniran za površinsku industriju Grupa II, Kategorija (3)G zona 2 za minimalnu i maksimalnu temperaturu okoline od -25°C do + 70°C. Oni ne treba da budu izlagani mehaničkim vibracijama.
Detektori se instaliraju vertikalno ( tip za zidnu montažu) sa kablovskim izlazom okrenutim nadole. Bilo koji ugao preko 45° za vertikalnu ili horizontalnu poziciju ( verzija za montažu na plafonu) proizvešće grešku u merenju i zahteva ponovnu kalibraciju OLC10 detektora.
22.. MMeettrroolloošškkee ssppeecciiffiikkaacciijjee zzaa OOLLCC 1100 ddeetteekkttoorr eekkssllppoo ggaassoovvaa
OLC 10 eksplozivni gas detektor je usklađen sa Evropskim standardima EN 61779-1 do 4 za metan (kalibracioni gas), butan, propan i vodonik ( gas sledeće krive odziva), kada ga koristite sa SV4B, MX32, MX43, MX52 Oldhamovim centralnim jedinicama.
Napomena: Test vibracija zasnivan na EN61779-4 odeljak 4.13 nije izveden jer oni se ne primenjuju zbog radnih uslova ovog tipa detektora.
2.1 Specijalne mere
Ćelije su osetljive na neke otrove koji mogu uzrokovati njihovo uništenje: silikonske pare sa koncentracijama > 10ppm, vrste hlorinata ili sulfida sa koncentracijama >100ppm.
Nedostatak kiseonika (<15% O2) ili višak kiseonika (>23% O2) mogu uzrokovati podcenjenje ili precenjenje merenja.
2.2 Reakcija na drugi eksplozivni gas
Preporučeno je kalibrisati detektore sa gasom koji mere.Kada korisnik želi da ga kalibriše sa drugim gasom od onog koji detektuje i na koji je podešen u fabrici, konsultovati donju tabelu, koristeći preporučeni gas i odgovarajuće koeficijente.
_________________________________________________________________________________________ 23
Tabela 1 : KOEFICIJENTI ZA KALIBRACIJU
Gas Empirijska formula LEL 1 LSE 1
Gustina pare
Keficijent CH4
Keficijent H2
Keficijent But
Butan C4H10 1.5% 8.5 % 2 1.75 1.25 1.0
Vodonik H2 4.0% 75.6% 0.069 1.25 1.0 0.8
Metan CH4 5.0% 15.0% 0.55 1.0 0.75 0.55
Propan C3H8 2.0% 9.5 1.6 1.5 1.1 0.85
Preporučeni gas za kalibraciju senzora. Napomena:
-LEL varira u zavisnosti od izvora. Ovi koji su ovde dati su u skladu sa Evropskim standardom EN 50054.
-Koeficijenti su precizni ± 15%
33.. OOzznnaaččaavvaannjjaa
3.1 Verzija OLC10/OLC10 Twin
OLDHAM Arras
OLC10 / OLC10 TWIN
II 3G EEx nA IIc T6 OSA 05ATEX0116 Caution: electrostatic loads. Rub or wipe with a damp cloth only. Serial number, year of fabrication.
3.2. Version OLCT 10
OLDHAM Arras
OLCT10
II 3G OSA 05ATEX0116 Caution: electrostatic loads. Rub or wipe with a damp cloth only. Serial number, year of fabrication.
VI I . D E C L AR AT I O N S O F CO N F ORM I TY
24
25
_________________________________________________________________________________________ 26
Mi garantujemo
1 Prednosti
Brzi i efikasni odgovor na vaš zahtev za konsultaciju ili praćenje porudžbine kroz ceo svet putem odeljenja za servis kupca.
Brz odgovor što je pre moguće na sva tehnička pitanja.
2 Kvalitet
Da Vam obezbedimo maksimalni kvalitet naših proizvoda i servisa u skladu sa međunarodnim standardima i direktivama na snazi.
3 Pregled i pouzdanost
Da Vam obezbedimo pouzdanost opreme. Kvalitet naših proizvoda je od ključne važnosti za pouzdanost. Ovo garantuju vrlo strogi pregledi koji se sprovode prilikom dolaska sirovog materijala, tokom proizvodnje i na konačnom proizvodu (sva oprema koja se pošalje je konfigurisana prema Vašim individualnim zahtevima).
4 Puštanje u rad
Ukoliko zahtevate, da pustimo u rad Vašu opremu od starne naših Ism-ATEX kvalifikovanih specijalista. To Vam garantuje dodatnu bezbednost.
5 Obuka
Da pružimo odgovarajući program obuke. 6 Odeljenje za projektovanje
Naš tim će istražiti sve Vaše projekte detekcije gasa i plamena na licu mesta ili putem crteža. Možemo da Vam sugerišemo pred-projketna rešenja, dizajn, instalaciju i održavanje bezbedonosnih sistema u ATEX ili ne ATEX zonama sa potpunim poštovanjem svih važećih standarda.
7 Ugovor o održavanju
Sugerišemo Ugovor o održavanju koji će biti usklađen sa Vašim potrebama da bi obezbedili Vašu savršenu bezbednost:
Jedna ili više poseta godišnje, uključujući potrošni materijal
Prećutno obnovljiv Ugovor,
Uključujući podešavanje stabilnih detektora, i inspekciju kontrolnog sistema.
8 Opravka na licu mesta
Brzo slanje naših specijalista za postprodajno održavanje kod Vas. Ovo je moguće zbog naših predstavništva u Francuskoj i inostranstvu.
9 Popravka u fabrici
Za svaki problem koji ne može da se reši na licu mesta oprema se šalje u fabriku. Tim specijalnih tehničara će odmah popraviti Vašu opremu što je god to moguće brže, redukujući na taj način utrošeno vreme na minimum.
_________________________________________________________________________________________ 27
Za post prodajni servis u Francuskoj, kontaktirajte nas na email: [email protected] ili na telefon 0800-OLDHAM (0800 653 426).
The Fixed Gas Detection People
EUROPEAN PLANT AND OFFICES Z.I. Est – rue Orfila B.P. 20417 – 62027 ARRAS Cedex FRANCE
Tél.: 33 3 21 60 80 80 – Fax: 33 3 21 60 80 00 Web site : http://www.oldhamgas.com
Za post prodajni servis u Srbiji, kontaktirajte nas na email: office“svecom.rs ili telefon +381 (0) 11 34 74 210