MVCBCT at UCSF A Team Creation

by Michèle AubinIGRT Specialist

Prostate Alignment

Page 2: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

Prostate Patient

Here is a typical Coherence screen after the 3D image acquisition and the automatic registration are done for a prostate patient.

Here is a typical Coherence screen after the 3D image acquisition and the automatic registration are done for a prostate patient.

Page 3: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- Click the ‘Fusion Bending’ tool, and the Blending Dialog will appear.

- Click the ‘Fusion Bending’ tool, and the Blending Dialog will appear.

Page 4: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- In the Blending Dialog window, slide to the left the blending tool (Cone Beam (CB) Image),

- Select Invert Grayscale in the Lookup Table and, adjust the Window-Values tool.

- In the Blending Dialog window, slide to the left the blending tool (Cone Beam (CB) Image),

- Select Invert Grayscale in the Lookup Table and, adjust the Window-Values tool.

Page 5: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- In the Blending Dialog window, slide to the right the blending tool (CT Reference Image),

- Select Grayscale in the Lookup Table and, adjust the Window-Values tool.

- In the Blending Dialog window, slide to the right the blending tool (CT Reference Image),

- Select Grayscale in the Lookup Table and, adjust the Window-Values tool.

Page 6: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

-Adjust the image with the Zoom tool.

-Adjust the image with the Zoom tool.

Page 7: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- In the Blending Dialog window, slide to the left the blending tool,

- On the coronal CB view (bottom), localize the three gold markers (GM) by scrolling images (Apex in this case).

- In the Blending Dialog window, slide to the left the blending tool,

- On the coronal CB view (bottom), localize the three gold markers (GM) by scrolling images (Apex in this case).

Page 8: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

(Right Base in this case)(Right Base in this case)

Page 9: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

(Left Base in this case)(Left Base in this case)

Page 10: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- In the coronal view, bring the red horizontal line over the left base GM . This will bring the GM in the transversal view (upper left).

- In the coronal view, bring the red horizontal line over the left base GM . This will bring the GM in the transversal view (upper left).

Page 11: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- In the coronal view, bring the green vertical line over the right base GM . This will bring the GM in the sagital view (upper right).

- In the coronal view, bring the green vertical line over the right base GM . This will bring the GM in the sagital view (upper right).

Page 12: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- In the coronal view, localize the apex GM . Now you have three different GM in each view; the left base in the transversal view (upper left), the right base in the sagital view (upper right) and the apex in the coronal view (bottom).

- In the coronal view, localize the apex GM . Now you have three different GM in each view; the left base in the transversal view (upper left), the right base in the sagital view (upper right) and the apex in the coronal view (bottom).

Page 13: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- Slide the blending tool to 1/3.

The CT and the CB appear together overlapping each other.

- Slide the blending tool to 1/3.

The CT and the CB appear together overlapping each other.

Page 14: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- Click on the Manual Registration tool and move the CT over the CB. Suggestion: Move the most obvious white CT-GM (in this case the right base) over the black CB-GM.

- Click on the Manual Registration tool and move the CT over the CB. Suggestion: Move the most obvious white CT-GM (in this case the right base) over the black CB-GM.

Page 15: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- Adjust one of the two other GM.- Adjust one of the two other GM.

Page 16: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment
Page 17: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- Click the Accept button.- Click the Accept button.

Page 18: MVCBCT at UCSF A Team Creation by Michèle Aubin IGRT Specialist Prostate Alignment

- On the left are the initial table coordinates.-On the middle are the new table coordinates (absolute).-On the right are the relative table moves.