LIPAc Control Systems A Reliability Approach

Alvaro Marqueta

LIPAc Project Team, Rokkasho, Japan

ARW’15, Knoxville, USA

Page 2: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA 2

Introduction to IFMIF/LIPAc

LIPAc -> Linear IFMIF Prototype Accelerator

IFMIF -> International Fusion Materials Irradiation Facility

(the fusion relevant neutron source)

Page 3: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 3 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

The first wall of the reactor vessel shall absorb neutrons energy

and breed tritium

ITER first wall will present <2 dpa at the end of its operational life

In a Fusion power plant

~150 dpa within 5 years are expected

Existing neutron sources do not provide the needed answers

Neutrons in first wall

Section of Vacuum Vessel of a Tokamak

Page 4: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 4 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

Deuterons at 40 MeV collide on a liquid Li screen

flowing at 15 m/s

IFMIF concept

A flux of 1018 n·m-2s-1 is stripped

with a broad peak at 14 MeV EVEDA Phase: LIPAc

Page 5: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 5 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

IFMIF/EVEDA phases

IFMIF/EVEDA A fruitful Japanese- European International collaboration

(under the Broader Approach Agreement)

EDA phase: EVA phase:

IFMIF I-EDR LIPAc

Test Facility

Target Facility

Page 6: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 6 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

Injector + LEBT CEA Saclay

RFQ INFN

JAEA Tokai MEBT CIEMAT Madrid

SRF Linac CEA Saclay

CIEMAT Madrid HEBT

CIEMAT Madrid BD CIEMAT Madrid

Diagnostics CEA Saclay

CIEMAT Madrid RF Power

CIEMAT Madrid CEA Saclay

SCK Mol

★ Rokkasho

Installed and commissioned in Rokkasho

EVEDA phase: LIPAc

Accelerator facility validation

Page 7: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 7 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

IFMIF/LIPAc Main Actors

IFMIF/EVEDA A fruitful Japanese- European International collaboration

(under the Broader Approach Agreement)

LIPAc contributions on control systems:

Japanese implementing agency

European implementing agency

(European coordinator) Central systems: - Network infrastructure - Central control system - Machine Protection system - Personnel Protection system - Timing system

Local control systems: - Injector + LEBT - RFQ - LLRF - MEBT - + (…) Beam Instrumentation

Page 8: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 8 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

IFMIF/LIPAc Main Actors

On-site organization: Japanese

implementing agency European

implementing agency

Integrated Team, responsible for: - Design Verification - Installation

coordination & QA - Commissioning - Operation - Systems

maintenance

Page 9: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 9 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

Local Control Systems

Injector + LEBT CEA Saclay

RFQ INFN

JAEA Tokai MEBT CIEMAT Madrid

SRF Linac CEA Saclay

CIEMAT Madrid HEBT

CIEMAT Madrid BD CIEMAT Madrid

Diagnostics CEA Saclay

CIEMAT Madrid RF Power

CIEMAT Madrid CEA Saclay

Overview of LIPAc Control Systems

Central Control System

Inje

ctor

RFQ

MEB

T

SRF

LIN

AC

HEBT

RF P

ower

LLRF

Beam

Inst

rum

enta

tion

MPS PPS

Timing System

EPIC

S

Envi

ronm

ent

Hard

wire

d En

viro

nmen

t

LAN

Page 10: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 10 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

LIPAc Control System: Main characteristics • Modular design, following the architecture of the whole

LIPAc, based on procurement ‘in-kind’: ₋ independent subsystems with common interface.

• Based on EPICS and CSS for software applications (OPI,

archiving, alarms…) ₋ common standardized EPICS platform

• Around 20.000 process variables managed globally

₋ considered medium size facility

• MPS fastest response (beam shutdown, hardwired loop) of around 20us ₋ But also has to manage slower PLC signals

Overview of LIPAc Control Systems

Page 11: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 11 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

Local Control Systems

Standard LCS architecture (standalone configuration) - European contribution, coordinated by CEA - EPICS standardization though guidelines, common EPICS/CSS platform - Delivered in local configuration to Rokkasho (to undergo acceptance tests before integration)

Local EPICS Apps

OPC Server

PLC VME

Field equipment (fast process)

Field equipment (slow process)

Profibus DP I/O signals

S7 Protocol

Channel Access Protocol

Modbus TCP I/O signals

Central Control System

Presenter
Presentation Notes
Developed independently by each institute According to common guidelines, that specify hw and sw and interfaces Designed to be able to operate in stand-alone mode (for individual system test – pre commissioning) But will be all coordinated from control room (CCS)
Page 12: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA 12

LIPAc Schedule

LIPAc Phase A

Injector checkout

Beam commissioning

LIPAc Phase B

RFQ Installation

Phase #2 commissioning

MEBT & D-plate Installation

LIPAc Phase C HEBT & Bdump Installation

Phase #3 commissioning

SRF Linac Installation

LIPAc Phase D

Phase A: Pulsed and CW, full intensity (125mA)

Phase B: Pulsed 0.01-0.1% DC, H+ and D+ full intensity (125mA)

Phase C: Pulsed 0.01-0.1% DC, H+ and D+ full intensity (125mA)

Phase D: Pulsed 0.1% DC to CW, H+ and D+ full intensity (125mA) Ramp up to full power

Currently…

Page 13: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 13 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

IFMIF Reliability Aspects

IFMIF inherent availability goals

Page 14: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA 14

Reliability of Control Systems

Recommended good practices during the design:

Control System Identification of critical components, implement redundancy in these systems

Good diagnosis tools, both HW and SW, for early identification of errors/failures

Standardize as much as possible, to reduce the catalogue of potential failures

Implement exhaustive V&V methodology, errors are less prone to occur when identified at the early design stages!

Use of isolation cards for I/O easier to identify when failures are localized

Page 15: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 15 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

First runtime experiences

LIPAc Ion source operating since November: • LCS “Successfully” commissioned mid-November (before ownership transfer)

• 3 month stop due to piping improvement in cooling system for safer D+ operation

• Several isolation and multiplexer cards IC damaged • Modbus modules communication problems • Old PLC interlocks still in place • Sometimes software still requires reboot…

Page 16: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 16 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

Early conclusions

When problems appear… • Documentation not always fully helpful (same with

drawings) • Remote support (+7/8h) limited availability • Several “black boxes” identified • Intervention on the delivered control system seems

unavoidable

Typical situations in in-kind procurement…

Page 17: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 17 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

The MPS particularities

• A trade-off between investment protection (avoid unsafe errors by all means) and availability (avoid spurious triggers as much as possible)

• LIPAc’s case: based on “proven” technology (derived from J-PARC experience)

• Looking for a redundant beam stop mechanism…

Page 18: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 18 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

The BRTZ case

• Increase availability by reducing re-arming time after beam shutdown:

• Directly Inhibiting the timing gate input • Valid for RF issues (arcs, reflected power) or BLoM events • Avoid reset and rearm by operator, when safety conditions

are met • Interfaces mostly LLRF, cavities and BLoM

Page 19: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta 19 Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA

Next steps

Page 20: LIPAc Control Systems - ORNL...Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA . 15 . First runtime experiences . LIPAc Ion source operating since November: • LCS

A. Marqueta Accelerator Reliability Workshop, 28 April 2015, Knoxville, USA 20