1/2" = 1'-0" (on an 11 x 17 sheet) Scale Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. Fabricator is responsible for fabrication and overall level of quality. Any changes in design, materials, fabrication method or other details must be approved by Corbin Design and Oregon Health & Science University. Notes 109 East Front Suite 304 Traverse City, MI 49684 231 947.1236 Date Description KNIGHT CANCER INSTITUTE ELECTRICAL FEED: Custom fabricate aluminum raceway with weather tight access panels to support necessary transformers and painted to match - dark gray. Use GTO sleeving for power supply conduit. INDIVIDUAL LETTERS: Colite LP4 Face Lit Letters (or equal) with silver metallic translucent vinyl over white acrylic faces and painted opaque returns. Sign appears silver metallic during the day and white faces at night when lighted. Letters are mounted to the aluminum frame using threaded fasteners, drill and tap method.FONT: Myriad SemiBold Condensed. All capital letters. ALUMINUM FRAME: Cutout 1/4" aluminum plate frame with bottom flange break-formed for attachment to U-channel and painted to match - silver metallic and dark gray. 3/8" x 1 1/4" aluminum bar mechanically fastened to backer frame using stainless steel fasteners and painted to match metallic silver. Sign must be appearance grade when viewed from behind. FRONT VIEW TOP VIEW SIDE VIEW LETTERS AND FRAME ASSEMBLED KNIGHT CANCER INSTITUTE KNIGHT CANCER INSTITUTE Equal sections of raceway covers (Removeable) 1 1/4" 5" 1/4" 1 3/4" 3" 1'-2" 1'-4 1/4" 14'-11" 14'-9 1/2" 08.30.13 Design Intent 10.21.13 Revised 05.03.18 Branding Update 49 STANDARDS MANUAL FOR WAYFINDING SIGNAGE

KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Sign Type

Ix-6a Individual Letters

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Notes

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

01.31.18 Review

KNIGHT CANCER INSTITUTEKNIGHT CANCER INSTITUTE

ELECTRICAL FEED:Custom fabricate aluminum raceway with weather tight access panels to support necessary transformers and painted to match - dark gray. Use GTO sleeving for power supply conduit.

INDIVIDUAL LETTERS:Colite LP4 Face Lit Letters (or equal) with silver metallic translucent vinyl over white acrylic faces and painted opaque returns. Sign appears silver metallic during the day and white faces at night when lighted. Letters are mounted to the aluminum frame using threaded fasteners, drill and tap method.FONT: Myriad SemiBold Condensed. All capital letters.

ALUMINUM FRAME:Cutout 1/4" aluminum plate frame with bottom flange break-formed for attachment to U-channel and painted to match - silver metallic and dark gray. 3/8" x 1 1/4" aluminum bar mechanically fastened to backer frame using stainless steel fasteners and painted to match metallic silver. Sign must be appearance grade when viewed from behind.

FRONT VIEW

TOP VIEW

SIDE VIEW

LETTERS AND FRAME ASSEMBLED

KNIGHT CANCER INSTITUTE

KNIGHT CANCER INSTITUTEKNIGHT CANCER INSTITUTE

Equal sections of raceway covers(Removeable)

1 1/4"

5"

1/4"

1 3/4"3"

1'-2"

1'-4 1/4"

14'-11"

14'-9 1/2"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

49STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 2: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

FRONT VIEWSIDE VIEW

������

�����������������������

Ix-6b INDIVIDUAL LETTERSScale: 1/4” = 1’-0“ on an 11” x 17” sheet

INTERNALLY ILLUMINATED INDIVIDUAL LETTERSThe total area of the sign equals 38.9 sq ft

FONT:Myriad SemiBold Condensed.All capital letters.

SERA & Fabricator to verify dimensions and location prior to fabrication and installation.

Letter Detail

6'-5 1/8"

WEST ELEVATION A317:

29'-8"

1'-6 1/2"1'-3 3/4" 1'-3 3/4"

50STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 3: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Ix-6b INDIVIDUAL LETTERS - DETAILScale: 1/2” = 1’-0“ on an 11” x 17” sheet

INDIVIDUAL LETTERS:Colite LP4 Face Lit Letters (or equal) with metallic silver translucent vinyl over white acrylic faces and painted opaque returns. Sign appears metallic silver during the day and white faces at night when lighted. Letters are mounted to the aluminum frame using threaded fasteners, drill and tap method.

ELECTRICAL FEED:Custom fabricate aluminum raceway with weather tight access panels to support necessary transformers and painted to match - dark gray. Use GTO sleeving for power supply conduit.

ALUMINUM FRAME:Cutout 1/4" aluminum plate frame with bottom flange break-formed for attachment to U-channel and painted to match - metallic silver and dark gray. 3/8" x 1 1/4" aluminum bar mechanically fastened to backer frame using stainless steel fasteners and painted to match metallic silver.

FRONT VIEWSIDE VIEW

LETTERS AND FRAME ASSEMBLED

TOP VIEW

1 3/16"

1/4"

1'-6 1/2"

1'-6 1/2"

1'-3 3/4"

1'-3 3/4"

29'- 8"

6 1/4"

6 1/4"

5 1/4"

4'-11 3/4"EQUAL SECTIONS OF RACEWAY COVERS

(removeable)

1 3/16"

6"1/4"

SECTION A

51STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 4: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

SECTION A

DETAIL:The above detail is for reference only and is not final. Fabricator to engineer letter attachment.

LOOKING SOUTH

5 1/4"

1'-3 3/4"

1'-6 1/2"

6 1/4"

2"

Letters attached to backer using countersunk stainless steel fasteners

LP4 FACE LIT LETTERS BY COLITE:White acrylic with white LED lighting embedded into acrylic

1/4" aluminum backer frame with cutout letter forms with break-formed base at 90° add gussets if necessary. Mount to U-channel using stainless steel mechanical fasteners.

Drill holes for necessary access for power supply at base of letters.

Custom raceway cover using 1/8” thick aluminum panel mounted to backer using L-brackets using countersunk stainless steel fasteners.

3/8" x 1 1/4" aluminum bar mechanically fastened to backer frame using stainless steel fasteners.

ELECTRICAL FEED:Owner is responsible for providing the electrical feed to the to sign. Fabricator to provide shop drawings showing detail of electrical location and specifications. Fabricator to provide final connection.

Custom aluminum fabricated U-channel painted to match canopy rafter. Mechanically fasten to rafter using stainless steel nut and bolt fasteners. Fabricator to field measure canopy rafter for tight fit and match bottom angle.

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-6bIndividual Letters Detail

52STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 5: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

INDIVIDUAL LETTERS:Colite LP4 Face Lit Letters (or equal) with metallic silver translucent vinyl over white acrylic faces and painted opaque returns. Sign appears metallic silver during the day and white faces at night when lighted. Letters are mounted to the aluminum frame using threaded fasteners, drill and tap method.

ELECTRICAL FEED:Custom fabricate aluminum raceway with weather tight access panels to support necessary transformers and painted to match - dark gray. Use GTO sleeving for power supply conduit.

ALUMINUM FRAME:Cutout 1/4" aluminum plate frame with bottom flange break-formed for attachment to U-channel and painted to match - metallic silver and dark gray. 3/8" x 1 1/4" aluminum bar mechanically fastened to backer frame using stainless steel fasteners and painted to match metallic silver.

FRONT VIEW1/2” = 1’-0”

SIDE VIEW1/2” = 1’-0”

LETTERS AND FRAME ASSEMBLED

TOP VIEW

SIGN: 12

1 3/16"

1/4"

1'-8 1/4"

1'-8"

1'-6"

1'-6"

6 1/4"

6"1/4"

SECTION A

4"

0808

08

12

12

4'-4 3/4"EQUAL SECTIONS OF RACEWAY COVERS

(removable)

22'-0"

1'-9"

21'-6"

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-6bBuilding Name Detail

53STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 6: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

SECTION ALOOKING SOUTH

1'-6"

1'-8 1/4"

2"

Letters attached to backer using countersunk stainless steel fasteners

LP4 FACE LIT LETTERS BY COLITE:White acrylic with white LED lighting embedded into acrylic

1/4" aluminum backer frame with cutout letter forms with break-formed base at 90° add gussets if necessary. Mount to U-channel using stainless steel mechanical

fasteners.

Drill holes for necessary access for power supply at base of letters.

Custom raceway cover using 1/8” thick aluminum panel mounted to backer using L-brackets using countersunk stainless steel fasteners.

Raceway mechanically fastened to existing canopy. Inset 2 1/2" from front edge.

ELECTRICAL FEED:Owner is responsible for providing the electrical feed to the to sign. Fabricator to provide shop drawings

showing detail of electrical location and specifications. Fabricator to provide final connection.

CANOPY DETAILS:TBD. Architect to supply drawings to awarded fabricator.

10"

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-6bBuilding Name Detail

54STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 7: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent07.29.16 For Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-7Entrance ID, ProjectingSmall, Illuminated

Exit Only

PPatientDrop-off

FRONT VIEW

ALTERNATE LAYOUTS1/2" = 1'-0"

END VIEW

TOP VIEW

268.5°

267.5°

3'-9"

3'-8"

1'-0" 4"

10"

2'-0 3/4"2'-5 1/2" 9 3/4"

1"

1 1/4"

3'-10 1/2"

5"7"

10"

1'-0"

2'-9"

4" square aluminum tube and mounting plate.

Copy and graphics to be push-through 1/32", 3/8" (th.) translucent white acrylic. Acrylic to be stud mounted to the back of the sign face. Illuminated using white LED's. Transfomers are to be located within the cabinet. Font: Gotham Condensed Medium

Signs are hard-wired, with electrical conduit to run through square aluminum tube frame into the sign cabinet.

05

Top and bottom rules painted to match silver metallic.

08

Main Cabinet and Installation:Aluminum channel frame with aluminum support tubes welded to an aluminum plate. Frame skinned with 1/8" (th.) painted aluminum faces to match silver metallic. Top and bottom skins attached with counter-sunk flush screws to cover hand holes for installation.

08

Face Cabinet (double-sided):1/8" (th.) aluminum faces painted to match blue and bonded to an aluminum tube frame. Faces are fixed in place.

01

08

07

6 1/2"

9 3/8"11 1/4"1'-7" 1'-5 1/2"

7"5"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

55STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 8: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent07.29.16 For Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-7aEntrance ID, ProjectingSmall, Non-illuminated

Exit Only

PPatientDrop-off

FRONT VIEW

ALTERNATE LAYOUT1/2" = 1'-0"

END VIEW

TOP VIEW

268.5°

267.5°

3'-9"

3'-8"

1'-0" 4"

10"

2'-0 3/4"2'-5 1/2" 9 3/4"

1"

1 1/4"

3'-10 1/2"

5"7"

10"

1'-0"

2'-9"

4" square aluminum tube and mounting plate.

Copy and graphics to be engineer grade reflective vinyl. Font: Gotham Condensed Medium

05

Top and bottom rules painted to match silver metallic.

08

Main Cabinet and Installation:Aluminum channel frame with aluminum support tubes welded to an aluminum plate. Frame skinned with 1/8" (th.) painted aluminum faces to match silver metallic. Top and bottom skins attached with counter-sunk flush screws to cover hand holes for installation.

08

Face Cabinet (double-sided):1/8" (th.) aluminum faces painted to match blue and bonded to an aluminum tube frame. Faces are fixed in place.

01

08

07

11 1/4"1'-7" 1'-5 1/2"

7"5"

6 1/2"

9 3/8"

ParkingElevator

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

56STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 9: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent07.29.16 For Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-8Entrance ID, Panel

AMBUL ANCE ONLY9'-4"

1'-2 1/2"

1 1/8"

Installation Detail

Side View Front View

10"

1" square aluminum tube frame with an 1/8" (th.) painted aluminum face bonded to frame. Copy and graphics to be opaque vinyl. Sign is mechanically fastened to the wall. Font: Gotham Condensed Medium.

Aluminum angle bracket fastened to the wall.

06

07

07

06

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

57STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 10: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-9Individual Letters –Illuminated

3/8" whiteacrylic face

stainless steelcounter sunk screw

.080" thick returns

See scale notes

Exterior Wall

1/8" thickback panel

White LED lights

Section Detail(trim cap)

Dark text on light backgroundLight text on dark background

High bond adhesiveto attach acrylic faceto letter return

Aluminum angle support

MountingHardwareStainless steel

counter sunk screw

3/8" whiteacrylic face

stainless steelcounter sunk screw

.080" thick returns

See scale notes

Exterior Wall

1/8" thickback panel

White LED lights

Section Detail(trimless)

High bond adhesiveto attach acrylic faceto letter return

Aluminum angle support

MountingHardwareStainless steel

counter sunk screw

Individual letters for building façades with dark background. Aluminum channel letters with white acrylic face and LED internal illumination. Letter returns are to be painted to match building facade or background panel color. Trim cap, if used, to be painted white. Interior of letterforms to be painted white or covered with 3M light enhancement film. Font: Gotham Condensed, Medium (or custom layout per project).

Alternate background panel fabricated from 1/8" (th.) aluminum painted to match project-specific custom color (see elevation).

07 Individual letters for building façades with light background. Aluminum channel letters with day/night acrylic faces and LED internal illumination. Letter returns are to be painted to match building facade or background panel color. Trim cap, if used, to be painted dark gray. Interior of letterforms to be painted dark gray or covered with 3M light enhancement film. Font: Gotham Condensed, Medium (or custom layout per project).

12

SCALE NOTE:The sign can be scaled

proportionally to accommodate various installation conditions or

signage codes.

SCALE• Letter height and scale to be determined based on

application and appropriate code requirements. • Channel letters located on the first or second story

of a building are to have 3" returns and trimless construction.

• Channel letters located on the third story or higher may use a low-profile trim cap.

• Jewel trim is not acceptable.

Low-profile trim cap(see scale notes)

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

58STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 11: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-9aIndividual Letters –Non-Illuminated

Dark text on light backgroundLight text on dark background

1/4" (th.) painted aluminum letters. flush-mounted to painted backer panel. Attach backer panel to existing masonry structure with studs welded to reverse side of panel, secured with silicone adhesive or other per code.

Side View with PanelSide View without Panel

Letters on a dark background painted to match White. Font: Gotham Condensed, Medium (or custom layout per project).

07 Letters on a light background painted to match Dark Gray. Font: Gotham Condensed, Medium (or custom layout per project).

12Alternate background panel fabricated from 1/8" (th.) aluminum painted to match project-specific custom color (see elevation).

SCALE NOTE:The sign can be scaled

proportionally to accommodate various installation conditions or

signage codes.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

59STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 12: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

05.31.12 Design Intent01.31.18 Review

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-10 Offsite Building ID(Vertical)

Family Medicineat Gabriel Park

4411 SW Vermont

TOP VIEW

SIDE VIEW SIDE VIEW(curb side)

FRONT VIEW

3/8" thick clear or whiteacrylic face

Stainless steelcounter sunk screw

.125" thick aluminum returns

1/8" thickback panel

White LED lights

High bond adhesiveto attach acrylic faceto aluminum return

Stainless steelcounter sunk screw

Rabbit notch acrylic to accept aluminum returns

Aluminum angle support

Section DetailAcrylic Face with Aluminum Cabinet

Section Detail

4'-2"

4'-3 3/4"

4'-5 3/4"

9"10"

4 1/2"9"

1'-3"5'-4 1/2"

3"

3'-4 3/4"

3"2"

1'-4"

4"

7'-2 1/2"

2 1/4"

3"

5"

3 1/4"

07

01

07

01

08

08

10

1 1/2"

1/8” thick aluminum fabricated base to have textured painted finish for a faux limestone appearance. Sign attachment, foundation and footing details to be engineered by fabricator.

All aluminum fabricated cabinet core, reveals and internal structure. Exterior surfaces painted to match brushed aluminum.

BODY PANEL1/8” thick aluminum sign face with cut-out/push-through white acrylic letters and numbers. Two-sided

HEADER PANEL3/8” thick acrylic sign face with mask and spray blue background with translucent white vinyl for logo symbol (see section details). Two-sided

Electrical connection to be coordinated by fabricator.

Two-sided, internally illuminated aluminum sign cabinet, fabricated from 1/8" (th.) material. To be illuminated with LED lighting system.

1 1/2"

1 1/2"

11"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

60STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 13: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

05.31.12 Design Intent01.31.18 Review

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-10 Layout Options

Clinic Nameat Location

1234 Street Name

PartnerHospital

1234 Street Name

Clinic Nameat Location

1234 Street Name

PartnerHospital

OHSU CLINIC PARTNER CLINICPARTNER HOSPITAL

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

61STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 14: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

05.31.12 Design Intent01.31.18 Review

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-10a Offsite Building ID(Horizontal)

Family Medicine at Richmond3930 SE Division Street

SIDE VIEW FRONT VIEW SIDE VIEW(curb side)

TOP VIEW

3/8" thick clear or whiteacrylic face

Stainless steelcounter sunk screw

.125" thick aluminum returns

1/8" thickback panel

White LED lights

High bond adhesiveto attach acrylic faceto aluminum return

Stainless steelcounter sunk screw

Rabbit notch acrylic to accept aluminum returns

Aluminum angle support

Section DetailAcrylic Face with Aluminum Cabinet

Section Detail

1 1/2"

1 1/2"

11"

07

01

07

01

BODY PANEL1/8” thick aluminum sign face with cut-out/push-through white acrylic letters and numbers. Two-sided

HEADER PANEL3/8” thick acrylic sign face with mask and spray blue background with translucent white vinyl for logo symbol (see section details). Two-sided

08

08

10

1/8” thick aluminum fabricated base to have textured painted finish for a faux limestone appearance. Sign attachment, foundation and footing details to be engineered by fabricator.

All aluminum fabricated cabinet core, reveals and internal structure. Exterior surfaces painted to match brushed aluminum.

Electrical connection to be coordinated by fabricator.

Two-sided, internally illuminated aluminum sign cabinet, fabricated from 1/8" (th.) material. To be illuminated with LED lighting system.

6'-6 5/8"

6'-5"

2 1/4"

1 1/2"

1'-3"4'-8"

3"

2'-8"

3"2"

1'-4"

4"

6'-6"

6'-7 1/2"6'-5"

6'-6 5/8"

9"4 1/2"

5"

3 1/4"

2 5/8"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

62STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 15: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

05.31.12 Design Intent01.31.18 Review

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-10a Layout Options

Partner Hospital1234 Street Name

Clinic Name at Location1234 Street Name

Clinic Name at Location1234 Street Name

Partner Hospital

OHSU CLINIC PARTNER CLINICPARTNER HOSPITAL

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

63STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 16: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

04.10.13 Design Intent04.25.13 Revised05.10.13 Design Submittal05.15.13 Revised Design01.31.18 Revised Logo

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-10c Offsite Building IDCustom

4212 SE Division Street2415 SE 43rd

SIDE VIEW FRONT VIEW

SIDE VIEW(curb side)

TOP VIEW

Electrical connectionto be coordinated by fabricator.

Concrete foundation depth to need of exceed local code.

Break-formed corners

Internal structure

3/8" thick white acrylic facewith masked and sprayed opaque graphics.

Translucent vinyl graphics

3"3"

1'-8 3/4"

01

07

07

08

08 All aluminum fabricated cabinet core, reveals and internal structure. Exterior surfaces painted to match brushed aluminum.

Internal steel structure. Post size and cross members to be engineered by fabricator.

Removable panel to access mounting bolts.

BODY PANEL1/8" thick aluminum sign face with masked and sprayed letters (Message on both sides).

1/8" thick aluminum sign face with masked and sprayed letters (Message on both sides).

Two-sided, internally illuminated aluminum sign cabinet, fabricated from 1/8" (th.) material. To be illuminated with LED lighting system.

6'-6 5/8"

6'-5"

1 1/2"

3"2"

1'-4"

4"

6'-7 1/2"6'-5"

6'-6 5/8"

9"4 1/2"

2 1/2"

6'-2 1/2"

2 1/4"

10 1/8" thick aluminum fabricated base to have textured painted finish for a faux limestone appearance. Sign mounting, foundation and footing details to be engineered by fabricator.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

64STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 17: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

nts

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-11 Offsite Building ID(Horizontal)

OHSU Clinics

Partner Hospital

TOP VIEW

SIDE VIEW

SIDE VIEW

FRONT VIEW - Layout Option 1

FRONT VIEW - Layout Option 2

Partner HospitalClinic Name

FRONT VIEW - Layout Option 3

Section Detail

Fro

nt

Flex Face Section Detail – Side View (nts)

Cover screwpart #5195

Break-formcover

#10 x 1/2" stainless steelscrew (every 8" – 10" oncenter depending on size of face).

Sign Comp™Bleed Fascia Frame

Part #2092

White LED lights

Mounting hardwareas required

Aluminum tubesupport frame

05.31.12 Design Intent01.31.18 Review

NOT TO SCALE

NOT TO SCALEFABRICATOR TO FIELD VERIFY DIMENSIONS

DO NOT EXCEED MAXIMUM SQ FT FOR ON BUILDING SIGNAGE ACCORDING TO LOCAL CODE

01

08

08

Internally illuminated (LED) sign cabinet with flexible fabric face and aluminum returns and back.Wall-mounted.

Surface applied transparent white vinyl for OHSU logo with opaque blue background.

SCALE NOTE:The sign can be scaled

proportionally to accommodate various installation conditions or

signage codes.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

65STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 18: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Ix-11a Offsite Building ID(Vertical)

PartnerHospital

OHSUClinics

TOP VIEW

SIDE VIEW SIDE VIEWFRONT VIEW - Layout Option1 FRONT VIEW - Layout Option 2

Clinic Name

FRONT VIEW - Layout Option 3

Fro

nt

Flex Face Section Detail – Side View (nts)

Cover screwpart #5195

Break-formcover

#10 x 1/2" stainless steelscrew (every 8" – 10" oncenter depending on size of face).

Sign Comp™Bleed Fascia Frame

Part #2092

Section Detail

White LED lights

Mounting hardwareas required

Aluminum tubesupport frame

PartnerHospital

01

08

08

Internally illuminated (LED) sign cabinet with flexible fabric face and aluminum returns and back.Wall-mounted.

Surface applied transparent white vinyl for OHSU logo and text with opaque blue backround.

SCALE NOTE:The sign can be scaled

proportionally to accommodate various installation conditions or

signage codes.

NOT TO SCALEFABRICATOR TO FIELD VERIFY DIMENSIONS

DO NOT EXCEED MAXIMUM SQ FT FOR ON BUILDING SIGNAGE ACCORDING TO LOCAL CODE

NOT TO SCALE

66STANDARDS MANUAL FOR WAYFINDING SIGNAGE

08.30.13 Design Intent10.21.13 Revised

Page 19: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

06.27.13 Design Intent10.21.13 Revised01.24.14 Revised01.31.18 Revised

Ix-12a,b,c,dRetrofit Panels

Ix-12a Retrofit Aluminum Panel, IlluminatedCut-out/Push-through copy

Ix-12b Retrofit Acrylic Panel, IlluminatedTranslucent

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

OHSU Clinics

Layouts:

OHSU Clinics

Partner Hospital

Partner Hospital

PartnerHospital

OHSUClinics

PartnerHospital

Clinic Name

Clinic Name

01

07 Push through acrylic logo to match white.

07 Push through acrylic messsaging to match white.Font: Gotham Condensed Medium.

RETROFIT:Replace existing aluminum panel with cut-out push-through acrylic messaging/graphics to match specified annotated sign layout.

Sign dimensions are location specific. See annotated layouts for approximate sizes. Fabricator to field verify before

creating shop drawings.

Acrylic panel painted to match blue.

Messaging knocked out of painted background.Font: Gotham Condensed Medium.

OHSU Clinics

Logo knocked out of painted background.

01

07

07

RETROFIT:Replace existing panel with new acrylic panel to match specified annotated sign layout.

Ix-12d Retrofit Aluminum Panel, Non-illuminatedMask and Spray

Individual painted message panel fabricated from 1/8” (th.) aluminum and internal structure as required to fit existing sign.

Messaging to be mask-and-spray painted to match white.Font: Gotham Condensed Medium.

OHSU Clinics

Logo to be mask-and-spray painted to match white.

01

07

07

RETROFIT:Replace existing sign panel with new painted aluminum panel and mask-and-spray graphics to match specified annotated sign layout.

Individual message panels fabricated from 1/8” (th.) aluminum and internal structure as required to fit existing sign.

Ix-12c Retrofit Aluminum Panel, Non-illuminatedReflective

OHSU Clinics01 Individual painted message panels

fabricated from 1/8” (th.) acrylic and internal structure as requied to fit existing sign.

07 Logo to be surface applied reflective vinyl to match white.

07 Messaging to be surface applied reflective vinyl to match white.Font: Gotham Condensed Medium.

RETROFIT:Replace existing sign panel with new painted aluminum panel and reflective graphics to match specified annotated sign layout.

Applied vinyl divder rule line 08

SCALE NOTE:The sign can be scaled

proportionally to accommodate various installation conditions or

signage codes.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

67STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 20: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Kx-1Pedestrian Map Kiosk

INFORMATION

Fabricated aluminum cabinet. Fabricator to field verify all mounting conditions and determine final mounting hardware. Masked and sprayed graphics.

SIDE VIEW

BACK VIEW

FRONT VIEW

TOP VIEW

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to preventgalvanic reaction between dissimilar metals.

083" square steel post. Wall thickness to be determined by fabricator. Post painted with

epoxy primer to prevent galvanic reaction between dissimilar metals.

3/16" high pressure laminate panelmap panel mechanically mounted to

sign cabinet with tamper-resistent stainless steel screws.

Internal steel post bolted to footing. External aluminum sleeve secured with counter-sunk screws painted to match post.

Internal steel bracket bolted to footing. External aluminum sleeve secured with

counter-sunk screws painted to match post.

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATORConcrete foundation

cylinder

Galvanized or stainless steel "J" Anchor Bolts

08 Fabricated aluminum panel constructed to support sign cabinet.

Tapered post cap08

01

02

4"1 1/4"

88°

92°

88°

3'-6 1/4"

2'-8 1/2"1/2"

6"2 1/8" 2'-1"

4'-10"

2'-0"

8"

2"

1"

3'-8 1/8"

1 1/2"

eq

3'-3 3/4"

1 1/2"5"

1 1/2"3"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

68STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 21: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Kx-2 Pedestrian Map, SmallWall Mounted

INFORMATION

3/16" high pressure laminate panelmap panel mechanically mounted to

sign cabinet with tamper-resistent stainless steel screws.

88°

92°

88°

3'-1/2"

2'-8 1/2"2 1/8" 2'-1"

4'-10"

8"

2"

1"

3'-8 1/8"

1 1/2"

eq

eq

3'-4"

1 1/2"5"

1 1/2"3"

TOP VIEW

SIDE VIEW FRONT VIEW

0102

Fabricated aluminum cabinet. Fabricator to field verify all wall conditions and determine final mounting hardware. Masked and sprayed graphics.

Painted band and return edgeswith surface applied reflective vinyl copy.

01

Fabricated aluminum cabinet. Painted band and return edges.

08

2"

3"

Approximately 2'-0"above grade

WALL MOUNTING BRACKETS AND/OR HARDWARE TO BE

ENGINEERED BY FABRICATOR

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

69STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 22: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

09.21.17 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Kx-3Parking KioskOptions

OPENFULL

OPENFULL

PRood FamilyGarage

PCHHGarage

05

0808

Fabricated aluminum cabinet. Fabricator to field verify all mounting conditions and determine final mounting hardware. Masked and sprayed graphics.

OPENFULL

OPENFULL

PRood FamilyGarage

PCHHGarage

Fabricated aluminum cabinet. Fabricator to field verify all mounting conditions and determine final mounting hardware. Masked and sprayed graphics.

Monochrome electronic LED message boards (one on each face)

mounted within sign cabinet. Product specifications TBD.

08

08

08

SIDE VIEW

FRONT VIEW

TOP VIEW

084" steel post. Wall thickness to be determined by fabricator. Post painted with

epoxy primer to prevent galvanic reaction between dissimilar metals.

Internal steel bracket bolted to footing. External aluminum sleeve secured with

counter-sunk screws painted to match post.

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

08 Fabricated aluminum panel constructed to support sign cabinet.

Can we reduce the size of the planter box to accommodate space for the Parking Kiosk?

Fire Hydrant

07Messaging is cutout, pushed-through flush white translucent acrylic copy and

parking symbol circles.

07Messaging is cutout, pushed-through flush white translucent acrylic copy and

parking symbol circles.

Monochrome electronic LED message boards (one on each face)

mounted within sign cabinet. Product specifications TBD.

05

0508

FRONT VIEW

TOP VIEW

084" steel post. Wall thickness to be determined by fabricator. Post painted with

epoxy primer to prevent galvanic reaction between dissimilar metals.

Internal steel bracket bolted to footing. External aluminum sleeve secured with

counter-sunk screws painted to match post.

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR Concrete foundation

cylinder

Galvanized or stainless steel "J" Anchor Bolts

05

OPTION 1 OPTION 2

GVLTT

B1

Q1

TYP.

TYP.

K3

TYP.K3TYP.H2 TYP.K1TYP.B2TYP.H1TYP.Q2TYP.P3TYP.C1TYP.P1TYP.Q4

B1

TYP.

TYP.

TYP.

TYP.

TYP. Q1

P1

C1

P3

Q7

TYP.B1 TYP.Q2TYP.P1 TYP.B1 Q2

GVLTT

B1

Q1

TYP.

TYP.

K3

TYP.H2 TYP.K1TYP.B2TYP.H1TYP.Q2TYP.P3TYP.C1TYP.P1TYP.Q4

B1

TYP.

TYP.

TYP.

TYP.

TYP. Q1

P1

C1

P3

Q7

TYP.B1 TYP.Q2TYP.P1

88°

92°

88°

2 1/8"

4'-10"

2'-0"

2'-8 5/8"

2'-11"

3'-1 1/8"

3"

10"

4"

SIDE VIEW

4"

10"

4'-5 3/16"

2'-1 1/2"

2'-8 1/2"

2'-8 1/2"

2'-2 1/8"

2'-2 1/8"

10"

10"

Proposed Parking Kiosk location

Manholes

Tram Track/Right Turn sign

Light Pole

Utility Vault

EXISTING PLAN RECOMMENDED PLAN

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

70STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 23: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

TOP VIEW

SIDE VIEW

AuthorizedPersonnel Only

See Front Security Desk for Entry

Loading Dock8:00am - 4:30pm

For assistanceplease call 503-250-2386

For after hours assistance please call 503-494-7744

For after hours assistance please call 503-494-7744

TOP VIEW

SIDE VIEW

1'-0"

1'-0"

1'-0"

1'-0"

NOTICE PLAQUE:1/8” Painted aluminum plaque with silk-screened copy and graphics.

Nx-1 NOTICE PLAQUEScale: 1 1/2” = 1’-0“ on an 11” x 17” sheet

Nx-1 NOTICE PLAQUEScale: 1/2” = 1’-0“ on an 11” x 17” sheet

AuthorizedPersonnel Only

See Front Security Desk for Entry

Loading Dock8:00am - 4:30pm

For assistanceplease call 503-250-2386

For after hours assistance please call 503-494-7744

AuthorizedPersonnel Only

See Front Security Desk for Entry

Loading Dock8:00am - 4:30pm

For assistanceplease call 503-250-2386

For after hours assistance please call 503-494-7744

1'-0"

1'-0"

1'-0"

1'-0"

5 1/2"

5 1/2"

1 5/8"

1 5/8"

1 1/8"

1 5/8"5/8"

FONT:Gotham Condensed,Medium @ 10% kerning

SMALL FONT:Gotham Condensed,Medium @ 5% kerning

FONT:Gotham Condensed,Medium @ 0% kerning

SMALL FONT:Gotham Condensed,Medium @ 5% kerning

2"

1 5/8"

1 1/8"3/4"

1 5/8"

1 1/8"

Nx-1Notice Plaque

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

71STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 24: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent10.21.13 Revised

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-1Garage IDFreestanding, LargeNon-Illuminated

Patients and Visitors park here for:

Hatfield Research Ctr

OHSU Hospital

Sam Jackson Hall

D

Visitor ParkingP

SIDE VIEW FRONT VIEW

Surface applied reflective vinyl 0705

REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue

with surface applied reflective vinyl graphics.

0705

TOP VIEW

08

08

DOUBLE-SIDEDFabricated aluminum cabinet.

Fabricated aluminum panel constructed to support sign cabinet.

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to preventgalvanic reaction between dissimilar metals.

08 Snap frame extrusion to allow message panel to be changed.

Painted band and return edgeswith surface applied reflective vinyl copy.

01

07

03 Masked and sprayed background field and white border with gold reflective graphics.

01

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATORConcrete foundation

cylinder

Galvanized or stainless steel "J" Anchor Bolts

Metal landscaping trim ring with drain holes.

Recess filled to grade with grey colored gravel.

Tapered post cap08

3'-9 1/2"

3'-2"2 1/2"

6"1/2"

3"

4"1 1/4"

2'-8"

11"

1"1 1/2"

1'-6"

4 3/4"2"

1 1/2"3 5/8"

3 5/8"

3 5/8"

3 5/8"

3 5/8"

6'-10 1/2"

2'-6"

4'-5 1/2"

1 1/4"

1'-11"

6 1/2"

5"

88°

92°

88° 1 1/2"THIS SIDE IS ALWAYSCLOSEST TO ROAD

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

72STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 25: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-1aGarage IDFreestanding, LargeIlluminated

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

Visitor ParkingP

FULLOPEN

SIDE VIEW FRONT VIEW

0705

REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue

with surface applied reflective vinyl graphics.

0705

TOP VIEW

08

08 Fabricated aluminum panel constructed to support sign cabinet.

Tapered post cap

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to preventgalvanic reaction between dissimilar metals.

08 Snap frame extrusion to allow message panel to be changed.

07

Custom LED symbol. Black whennot illuminated. Red LED “X” when illuminated.

01

03

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

DATA SOURCE NOTEOwner to provide hardwire data

connection at sign location.

ALTERNATE DATA SOURCEWireless data connection moduleincorporated into sign cabinet.

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

Metal landscaping trim ring with drain holes.

Recess filled to grade with grey colored gravel.

Cut-out, pushed-through flush white translucent acrylic circle with surface applied translucent graphic.

Cut-out, pushed-through flush white translucent acrylic panel with surface applied translucent graphic.

DOUBLE-SIDEDINTERNALLY ILLUMINATEDFabricated aluminum cabinet. White LEDs to back light 12" circle and triple diamond symbol.

Painted band and return edgeswith surface applied reflective vinyl copy.

Painted band and return edges

Quantity 2 (one for each side)7"H x 18"W x 2.5"deep commercially available TCL LED direct-view display.OPEN (green) FULL (red)

01

11

08

Electrical/data connection to be coordinated by fabricator and owner representative.

3'-9 1/2"

3'-2"2 1/2"

6"1/2"

3"

4"1 1/4"

2'-8"

11"

1"1 1/2"

1'-6"

2"1 1/2"3 5/8"1 3/4"3 5/8"

3 5/8"

3 5/8"6'-10 1/2"

2'-6"

4'-5 1/2"

1 1/4"

1'-11"

6 1/2"

5"

2 3/4"

2 3/4"

88°

92°

88° 1 1/2"

THIS SIDE IS ALWAYSCLOSEST TO ROAD

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

73STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 26: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent10.21.13 Revised

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-1bGarage IDFreestanding, LargeIlluminated w/ Display

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

FULLOPEN

DatronicsAF-3200

SIDE VIEW FRONT VIEW

0705

TOP VIEW

08

08 Fabricated aluminum panel constructed to support sign cabinet.

Tapered post cap

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals.

086" wide x 4" deep fabricated aluminum support leg with 3" internal steel post. Post

painted with epoxy primer to prevent galvanic reaction between dissimilar metals.

07

Custom LED symbol. Black whennot illuminated. Red LED “X” when illuminated.

01

03

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

DATA SOURCE NOTEOwner to provide hardwire data

connection at sign location.

ALTERNATE DATA SOURCEWireless data connection moduleincorporated into sign cabinet.

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

Metal landscaping trim ring with drain holes.

Recess filled to grade with grey colored gravel.

Cut-out, pushed-through flush white translucent acrylic circle with surface applied translucent graphic.

Cut-out, pushed-through flush white translucent acrylic panel with surface applied translucent graphic.

DOUBLE-SIDEDINTERNALLY ILLUMINATEDFabricated aluminum cabinet. White LEDs to back light 12" circle and triple diamond symbol.

Painted band and return edgeswith surface applied reflective vinyl copy.

Painted band and return edges

Quantity 2 (one for each side)7"H x 18"W x 2.5"deep commercially available TCL LED direct-view display.OPEN (green) FULL (red)

Double-sided 19"H x 34"W x 10" deep (5" deep each) Daktronics AF-3200

8mm pixel amber LED displays.

01

11

Fabricated aluminum cabinet.11

08

Electrical/data connection to be coordinated by fabricator and owner representative.

3'-9 1/2"

3'-2"2 1/2"

6"1/2"

3"

4"1 1/4"

2'-8"

11"

1"1 1/2"

1'-6"

2"1 1/2"3 5/8"1 3/4"3 5/8"

3 5/8"

3 5/8"6'-10 1/2"

2'-6"

4'-5 1/2"

1 1/4"

1'-11"

6 1/2"

5"

3"

3"

10"

88°

92°

88° 1 1/2"THIS SIDE IS ALWAYSCLOSEST TO ROAD

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

74STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 27: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-2Garage IDProjectingIlluminated

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

Visitor ParkingP

FRONT VIEW SIDE VIEW

SIDE VIEW FRONT VIEW

TOP VIEW

08

08 Fabricated aluminum panel constructed to support sign cabinet.

08 6" half round aluminum post.

08 Snap frame extrusion to allow message panel to be changed.

Painted band and return edgeswith translucent white copy.

01

07

0301

MOUNTING BRACKET AND ANY ADDITIONALSTRUCTURAL SUPPORT WITHIN THE WALL TO

BE ENGINEERED BY FABRICATOR

DOUBLE-SIDEDFabricated aluminum cabinet.

Tapered post cap080705Translucent graphics

Translucent graphics

3'-5"

3'-2"2 1/2"

88°

92°

3"1/2"

3"

4" 1 1/4"

2'-8"

11"

1"1 1/2"

1'-6"

6'-10 1/2"

Final height tobe determined

4'-5 1/2"

1 1/4"

1'-11"

5 3/8"

2"1 1/2"3 5/8"1 3/4"3 5/8"

3 5/8"

3 5/8"

6 1/2"

5"

1 1/2"

DOUBLE-SIDEDINTERNALLY ILLUMINATEDFabricated cabinet with white LEDs.Panaflex faces for upper cabinet with opaque background and internally illuminated letters and graphics.

Flexface cabinet

REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue

with surface applied reflective vinyl graphics.

0705

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

75STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 28: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-2b/Px-2cGarage ID, ElectronicProjecting/Wall Mounted

92°

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

FULLOPEN

DatronicsAF-3200

6 1/2"

5"

3"

3"

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

FULLOPEN

DatronicsAF-3200

6 1/2"

Px-2b SIDE VIEW Px-2b FRONT VIEW Px-2c FRONT VIEW

TOP VIEW

08

08 Fabricated aluminum panel constructed to support sign cabinet.

08 6" half round aluminum post.

Painted band and return edgeswith translucent white letters

01

07

0301

MOUNTING BRACKET AND ANY ADDITIONALSTRUCTURAL SUPPORT WITHIN THE WALL TO

BE ENGINEERED BY FABRICATOR

Surface applied translucent graphic.

Px-2c is a single side wall mounted verison of the Px-2b.

DOUBLE-SIDEDINTERNALLY ILLUMINATEDFabricated cabinet with white LEDs.Panaflex faces for upper cabinet with opaque background and internally illuminated letters and graphics.

Fabricated aluminum cabinet

Tapered post cap08

Electrical connection to be coordinated by fabricator and

owner representative.

0705illuminated circle with surface applied translucent graphic.

Flexface cabinet

Fabricated aluminum cabinet

Custom LED symbol. Black whennot illuminated. Red LED “X” when illuminated.

DATA SOURCE NOTEOwner to provide hardwire data

connection at sign location.

ALTERNATE DATA SOURCEWireless data connection moduleincorporated into sign cabinet.

Quantity 2 (one for each side)7"H x 18"W x 2.5"deep commercially available TCL LED direct-view display.OPEN (green) FULL (red)

Double-sided 19"H x 34"W x 10" deep (5" deep each) Daktronics AF-3200

8mm pixel amber LED displays.

3'-5"

3'-2"2 1/2"

88° 88°

92°

3"1/2"

3"

4" 1 1/4"

2'-8"

11"

1"1 1/2"

1'-6"

6'-10 1/2"

Final height tobe determined

4'-5 1/2"

1 1/4"

1'-11"

2"1 1/2"3 5/8"1 3/4"3 5/8"

3 5/8"

3 5/8"

10"

1 1/2"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

76STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 29: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent70.08.14 Revised

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-2dGarage IDWall MountedNon-Illuminated

Park here for:

DoernbecherChildren’s Hospital

OHSU Hospital

D

Visitor ParkingP

FRONT VIEW

MOUNTING BRACKET AND ANY ADDITIONALSTRUCTURAL SUPPORT WITHIN THE WALL TO

BE ENGINEERED BY FABRICATOR

0705Reflective graphics

TOP VIEW

SIDE VIEW

08 Fabricated aluminum cabinet. Fabricator to field verify all wall conditions and determine final mounting hardware.

08 Snap frame extrusion to allow message panel to be changed.

Painted band and return edgeswith surface applied reflective vinyl copy.

01

2"

4"

3'-5"

3'-2"2 1/2"

88°

92°

3 1/2"

3"

2'-8"

11"

1"1 1/2"

1'-6"

6'-10 1/2"

Final height tobe determined

4'-5 1/2"

1 1/4"

1'-11"

5 3/8"

2"1 1/2"3 5/8"1 3/4"3 5/8"

3 5/8"

3 5/8"

1 1/2"

Flexface cabinet

REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue

with surface applied reflective vinyl graphics.

0705

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

77STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 30: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent07.29.16 For Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-2eGarage ID, Projecting, Small, Illuminated

Rood FamilyPavilion

P OPENFULL

Center forHealth & Healing

P OPENFULL

ALTERNATE LAYOUT1/2" = 1'-0"

FRONT VIEWEND VIEW

TOP VIEW

3'-9 1/2"

3'-10 1/4"

3'-1 1/2"

1'-7"

1'-3 1/2"

4 1/2"

6"

1'-4"

1'-3"

07

Main Cabinet and Installation:Aluminum channel frame skinned with 1/8" (th.) painted aluminum faces to match silver metallic. Cabinet is mounted flush to the wall. Awarded fabricator to engineer the mounting details. Architect to provide wall cross-sections drawings to awarded fabricator.

08

Quantity 2 (one for each side)7"H x 18"W x 2.5"deep commercially available TCL LED direct-view display.OPEN (green) FULL (red). Displays may sit proud of face up to 1", prefer 1/2".

Lower Face Cabinet (double-sided):Removable 1/8" (th.) aluminum panels installed into a thin retainer system. Painted to match blue (panels and retainers). Retainers on side of sign to be easily removed for access to insert panels. Copy to be push-through 1/32", 3/8" (th.) translucent white acrylic. Acrylic to be stud mounted to the back of the aluminum insert panel. Illuminated using white LED's. Transfomers are to be located within the cabinet. Font: Gotham Condensed Medium

05

Upper Face Cabinet (double-sided):1/8" (th.) aluminum faces painted to match blue and bonded to an aluminum tube frame. Faces are fixed in place. Parking symbol to be push-through 1/32", 3/8" (th.) translucent white acrylic with translucent blue vinyl on first surface. Acrylic to be stud mounted to the back of the sign face. Illuminated using white LED's. Transfomers are to be located within the cabinet.

05

07

08

1'-6"

1/2"

2 1/2"

7"

5"

1'-7"

1'-3 1/2"

Signs are hard-wired, with electrical conduit to run into the sign cabinet.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

78STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 31: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent10.21.13 Revised01.31.18 Revised

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-3 Garage IDBulkhead Mounted

SIDE VIEW FRONT VIEW

2"

4"

TOP VIEW

Electrical connection to be coordinated by fabricator and owner representative.

88°

92°

88°

WALL MOUNTING BRACKETS AND/OR HARDWARE TO BE

ENGINEERED BY FABRICATOR

A Park here for:

Emma Jones Hall

07

0301

1'-6" 1'-0"

1"eq

eq

08

translucent circle with surface applied translucent graphic.

0705

6'-7"

6'-3 1/2"

2 1/8"

2'-3"

4"

1'-9 1/2"

1 1/2"

2 1/2"

6"

2 1/8"3 5/8"

4 1/2"INTERNALLY ILLUMINATEDFabricated cabinet with white LEDs.Panaflex faces with opaque background and internally illuminated letters and graphics.

Flexface cabinet

Fabricated aluminum cabinetto form background element.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

79STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 32: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-3a Garage IDWall Mounted,Custom Curve

01.31.18 Revised

CPatients and Visitors

Park here for:OHSU Hospital and Sam Jackson Hall

SIDE VIEW FRONT VIEW

TOP VIEW

ALTERNATE LAYOUT

88°88°

1'-6" 1'-0"

1"eq

eq

Surface applied white reflective circle with translucent parking blue field with cut out letter.

Surface applied white reflective graphics.07

0705

C Permit Parking Only

07

03 Masked and sprayed background field and white border with gold reflective graphics.

01

1/8” thick painted aluminum panel.

01

MOUNTING TO BEENGINEERED BY FABRICATOR

CUSTOM CURVED PANEL REQUIRED.FABRICATOR TO FIELD VERIFY CURVE DIMENSIONS.

Masked and sprayed graphics

01

08

07

6'-3 1/2"

2 1/8"

1'-9 1/2"

9"

3 5/8"

4 1/2"

3 5/8"

3 3/4"2 7/8"2 5/8"1 3/4"2 5/8"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

80STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 33: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-4Garage IDFreestanding, Small

APark here for:

Emma Jones Hall

Visitor ParkingP

APark here for:

Emma Jones Hall

Visitor ParkingP

SIDE VIEW

BACK VIEW

0705

REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue

with surface applied reflective vinyl graphics.

07

07

03

05

TOP VIEW

08

08

DOUBLE-SIDEDFabricated aluminum cabinet.

Fabricated aluminum panel constructed to support sign cabinet.

Masked and sprayed background field and white border with gold reflective graphics.

08 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to preventgalvanic reaction between dissimilar metals.

083" square steel post. Wall thickness to be determined by fabricator. Post painted with

epoxy primer to prevent galvanic reaction between dissimilar metals.

08 Snap frame extrusion to allow message panel to be changed.

Painted band and return edgeswith surface applied reflective vinyl copy.

01

01

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

Metal landscaping trim ring with

drain holes.

Recess filled to grade with grey colored gravel.

Tapered post cap08Surface applied reflective vinyl

FRONT VIEW

Concrete foundation cylinder

Galvanized or stainless steel "J" Anchor Bolts

3'-9 1/2"

5'-6"

3'-2"

3'-1"

1 1/4"

1'-11"

2 1/2"

1'-3 1/2"

1'-6" 1'-0"

1"2"

3 3/4"2"

1 1/2"3"

3"

6"1/2"

1'-10"

4"1 1/4"

6 1/2"

5"

88°

92°

88° 1 1/2"

THIS SIDE IS ALWAYSCLOSEST TO ROAD

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

81STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 34: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-5Staff Lot IDFreestanding

TOP VIEW

10

07

07

Reflective vinylgraphics

Reflectivevinyl graphics

REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue with surface

applied reflective vinyl graphics.

0705

StaffParking

SIDE VIEW

BACK VIEW

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

FRONT VIEW

083" square aluminum post. Wall thickness to be

determined by fabricator.

Concrete foundation cylinder

1/8" thick aluminum plate

2'-2"

2 3/8"

1'-2 1/2"

7/8"2 1/2"

8 3/8"

12

3'-3"

2'-6 1/2"

1'-8"

5 1/8"

4"1 3/4"

08 Snap frame extrusion to allow message panel to be changed.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

82STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 35: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Px-6a GARAGE EXIT IDENTIFI-ER, WALL-MOUNTED, ILLUMI-NATEDPainted aluminum sign cabinet with cut-out push-through white acrylic circle and applied red translucent vinyl.

Px-6 GARAGE ENTRANCE IDENTIFIER, WALL-MOUNTED, ILLUMINATEDPainted aluminum sign cabinet with cut-out push-through white acrylic letters. Painted PVC clearance bar with applied vinyl graphics and lettering. Clearance bar to have end caps.

EXIT ONLY

0'-0" Clearance

ENTR ANCE

8'-0"

1'-4 3/4"

8'-0"

1'-4 3/4" P P

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3/4" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-6/Px-6aGarage Entrance ID

Wall Mounted

Px-6dGarage Clearance Bar

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

83STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 36: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

ENTRANCEP P??'-??" Clearance

NOT AN EXIT

FRONT VIEW

BACK VIEW

SIDE VIEW

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent07.29.16 For Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-6bGarage Entrance IDClearance Bar, IlluminatedDouble-sided

4"

6"

2 1/4"6"

SIGN CABINET:Internally-illumined, double-sided painted aluminum cabinet fabricated from 1/8" (th) aluminum. Copy and graphics to be push-through 1/32", 3/8" (th.) translucent white acrylic. Acrylic to be stud mounted to the back of the sign face. Illuminated using white LED's. Transfomers are to be located within the cabinet. Center copy vertically on sign face and horizontally between parking symbols. Font: Gotham Condensed Medium

05

CLEARANCE PANEL AND CHAINS:Painted aluminum cabinet with mask and spray graphics. Chain height and number to be coordinated with parking consultant.Font: Gotham Condensed Medium

00

11

INSTALLATION:2 1/4" sq. aluminum tube with welded mounting plate mechanically fastened to building. Engineering to be provided by awarded fabricator. Electrical feed to run through one of the support tubes.

08

06

07

08

TBD, based on clearance height.

1'-6" 1'-0" 9"

7" 4"

8'-6"1'-6"

5'-6"

Signs are hard-wired, with electrical conduit to run through square aluminum tube frame into the sign cabinet.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

84STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 37: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

EXIT ONLY

LEFT TURN ONLY

6"

2 1/4"6"

SIGN CABINET:Internally-illumined, double-sided painted aluminum cabinet fabricated from 1/8" (th) aluminum. Copy and graphics to be push-through 1/32", 3/8" (th.) translucent white acrylic. Acrylic to be stud mounted to the back of the sign face. Illuminated using white LED's. Transfomers are to be located within the cabinet. Center copy vertically on sign face and horizontally between parking symbols. Font: Gotham Condensed Medium

05

INSTALLATION:2 1/4" sq. aluminum tube with welded mounting plate mechanically fastened to building. Engineering to be provided by awarded fabricator. Electrical feed to run through one of the support tubes.

08

06

07

08

TBD, based on clearance height.

1'-6" 1'-0" 9"

9"

8'-6"1'-6"

FRONT VIEW

BACK VIEW

SIDE VIEW

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

06.27.13 Design Intent07.29.16 For Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-6cGarage Exit IDIlluminated, Double-sided

1'-6"

8'-6"3" 3"

Signs are hard-wired, with electrical conduit to run through square aluminum tube frame into the sign cabinet.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

85STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 38: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-6dGarage Clearance Bar

SIDE VIEW FRONT VIEW

7'-0" Clearance

7'-0" Clearance – 8'-2" Accessible Clearance

4"

CLEARANCE PANEL AND CHAINS:Painted aluminum cabinet with mask and spray graphics. Chain height and number to be coordinated with parking consultant.Font: Gotham Condensed Medium.

Sign to be attached to entrance drive portal. Portal design to be prepared by SRG and will extend over the drive aisle. Fabricator to engineer attachment of clearance bar to entrance drive portal sign.

00

11

7"

9'-1"

SIDE VIEW FRONT VIEW

4"

CLEARANCE PANEL AND CHAINS:Painted aluminum cabinet with mask and spray graphics. Chain height and number to be coordinated with parking consultant.Font: Gotham Condensed Medium.

Fabricator to engineer attachment.

00

11

7"

9'-1"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

86STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 39: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Px-6e GARAGE ENTRANCE ID w/ CLEARANCE BARScale: 1/2” = 1’-0“ on an 11” x 17” sheet

Px-6f GARAGE EXIT IDENTIFIERScale: 1/2” = 1’-0“ on an 11” x 17” sheet

Parking Entrance PP Exit Only

NOT AN EXIT Left Turn Only

7'-0" Clearance – 8'-2" Accessible Clearance

13'-7"

1'-6"

10'-0"

1'-6"

Distance to bedeterminedby Owner

Distance to bedeterminedby Owner

8 1/2"1'-2"

4"

8 1/2"1'-2"

2'-4" 2'-4"2'-3"2'-3"

13'-7"

1'-6" 8 1/2"1'-2"

2'-3"2'-3"

4"

6" 2'-3" 9'-1"

9 1/4"

11 3/8"

8 3/8"

10'-0"

1'-6"

2'-4" 5'-4"6"

SYMBOLS:Cut-out pushed-through white acrylic circle and dash with surface applied red translucent vinyl.

SYMBOLS:Cut-out pushed-through white acrylic with blue translucent vinyl.

SIGN CABINET:Painted aluminum cabinet with cut-out pushed-through white acrylic letters. Center copy vertically on sign face and horizontally between do not enter symbols.

FONT:Gotham Condensed, Medium.Optical kerning set @ 50%

SIGN CABINET:Painted aluminum cabinet with cut-out pushed-through white acrylic letters and circle P symbol. Center copy vertically on sign face and horizontally between parking symbols.

MOUNTING:Mounting height to be determined on site. Owner to verify clearance.

MOUNTING:Mounting height to be determined on site. Owner to verify clearance.

BACK VIEW BACK VIEW

SIGN CABINET FONT:Gotham Condensed, Medium.Optical kerning set @ 50%

SIGN CABINET FONT:Gotham Condensed, Medium.Optical kerning set @ 50%ALL CAPITAL LETTERS.

CLEARANCE CHAINS:To be coordinated with parking consultant.

CLEARANCE BAR FONT:Gotham Condensed, Medium.Optical kerning set @ 25%

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-6e/Px-6fGarage Entrance/Exit ID

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

87STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 40: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Px-7a GARAGE EXIT IDENTIFIER, WALL-MOUNTED, NON-ILLUMINATEDPainted aluminum sign cabinet with reflective vinyl letters and graphics.

Px-7 GARAGE ENTRANCE IDENTIFIER, WALL-MOUNTED, NON-ILLUMINATEDPainted aluminum sign cabinet with reflective vinyl letters and graphics. Painted PVC clearance bar with applied vinyl graphics and lettering. Clearance bar to have end caps.

CUSTOM MOUNTING CONDITIONSClean and repaint existing overhead steel structure OHSU parking blue. Mount Px-7 and Px7a to horizontal cross member.

E X I T O N LY

0'-0" Clearance

E N T R A N C E

8'-0"

1'-4 3/4"

8'-0"

1'-4 3/4"

SIDE VIEW

SIDE VIEW

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3/4" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-7Garage Entrance IDWall Mounted

RENDERING OF LOCATION 1

RENDERING OF LOCATION 2

0'-0" Clearance

E N T R A N C EE X I T O N LY

0'-0" Clearance

E N T R A N C EE X I T O N LY

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

88STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 41: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

SIDE VIEW

SIDE VIEW

3/4" = 1'-0"(on an 11 x 17 sheet)

Parking

Parking

9 1/8"2'-1"

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-8/8a/8.2Overhead Guide, Long

SIDE VIEW

6 1/2"1'-0"

5'-6"

6 1/2"1'-0"

5'-6"

Px-8 Suspended Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Px-8.2 Suspended, double-sided Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Px-8a Beam Mounted Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Aluminum frame is mechanically fastened to ceiling.

NOTE: Fabricator to verify ceiling heights prior to construction to maintain posted clearance height and determine frame tube lengths.

FONT:Gotham Condensed Mediumkerning set at 50%.

FONT:Gotham Condensed Mediumkerning set at 25%.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

89STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 42: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

ALTERNATE LAYOUTS

3/4" = 1'-0"(on an 11 x 17 sheet)

Parking Exit

Park ExitExpress LaneCredit Cards, Permits, Validations

Level

3"

3 1/4"

3 1/4"

P6Level

P6Level

P 1

Elevators Valet Pickup

Right Turn Only Level P3Patient & Patient Visitor Parking

3"

3 1/4"

3 1/4"

Right TurnOnly

ExitBadge AccessOnly

Exit/Parking

Level P5Permit Parking OnlyP5Level P2

Guest House Parking OnlyP2

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-8/8a/8.2Layout Options

1'-5"

2'-1"

4 1/2"

2"1"

1"

5 3/8"

1'-5 5/8" 2'-8"

5'-6"

1'-1 1/4"

1"

5 3/8"

1'-5 5/8" 2'-8"

3 1/4"

1"

5 3/8"

1'-5 5/8" 2'-8"

Layouts for parking levels

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

90STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 43: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

SIDE VIEW

SIDE VIEW

3/4" = 1'-0"(on an 11 x 17 sheet)

Parking7 5/8"

1'-8 3/4"

Right Turn Only11"

SIDE VIEW

10"

4'-7"

10"

4'-7"

5 1/2"

Px-8b Suspended Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Px-8b.2 Suspended, double-sided

Painted 1/8” aluminum panel with reflective vinyl

letters and graphics.

Px-8c Beam Mounted Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Aluminum frame is mechanically fastened to ceiling.

Aluminum frame is mechanically fastened to ceiling through 4" layer of insulation.

NOTE: Fabricator to verify ceiling heights prior to construction to maintain posted clearance height and determine frame tube lengths.

FONT:Gotham Condensed Mediumkerning set at 50%.

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-8b/8c/8b.2Overhead Guide, Long

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

91STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 44: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

SIDE VIEW

SIDE VIEW

ALTERNATE LAYOUTS

3/4" = 1'-0"(on an 11 x 17 sheet)

Parking

Parking

Exit No Exit

1'-0"

1'-0"

4'-7"

6 1/2"

1'-0"

4'-7"

9 1/8"

Px-9 Suspended Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Px-9a Beam Mounted Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Aluminum frame is mechanically fastened to ceiling.

NOTE: Fabricator to verify ceiling heights prior to construction to maintain posted clearance height and determine frame tube lengths.

SIDE VIEW

Px-9.2 Suspended, double-sided Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

FONT:Gotham Condensed Mediumkerning set at 50%.

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-9/9a/9.2Overhead Guide, Short

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

92STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 45: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

SIDE VIEW

SIDE VIEW

ALTERNATE LAYOUTS

3/4" = 1'-0"(on an 11 x 17 sheet)

Exit

No Exit

Parking10"

7 5/8"

SIDE VIEW

10"

3'-10"

10"

3'-10"

5 1/2"

Px-9b Suspended Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Px-9b.2 Suspended, double-sided Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Px-9c Beam Mounted Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Aluminum frame is mechanically fastened to ceiling.

Aluminum frame is mechanically fastened to ceiling through 4" layer of insulation.

NOTE: Fabricator to verify ceiling heights prior to construction to maintain posted clearance height and determine frame tube lengths.FONT:

Gotham Condensed Mediumkerning set at 50%.

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-9b/9c/9b.2Overhead Guide, Short

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

93STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 46: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

SIDE VIEW

SIDE VIEW

3/4" = 1'-0"(on an 11 x 17 sheet)

Two-way Traffic

Two-way Traffic

Two-way Traffic

4 5/8"

9 3/8"

1'-2 3/4"

FONT:Gotham Condensed Mediumkerning set at 25%.

4'-7"

1'-0"

4'-7"

1'-0"

Px-10 OVERHEAD TWO WAY TRAFFIC, SUSPENDEDPainted 1/8” aluminum panel with black reflective vinyl letters and graphics.

Px-10a OVERHEAD TWO WAY TRAFFIC, BEAM MOUNTEDPainted 1/8” aluminum panel with black reflective vinyl letters and graphics.

Back-view

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-10, Px-10aOverhead Two Way TrafficLong

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

94STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 47: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3/4" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-11, Px-11aOverhead ClearanceSuspended/Beam Mounted

0'-0" Clearance

Caution: Clearance Change

Caution: Clearance Change

0'-0" Clearance

4'-7"

1'-0"

4'-7"

1'-0"

4"

Px-11 OVERHEAD CLEARANCE, SUSPENDED

Painted 1/8” aluminum panel with black reflective vinyl letters and graphics. Painted PVC clearance bar with applied vinyl graphics and lettering. Clearance bar to have end caps.

Px-11a OVERHEAD CLEARANCE, BEAM MOUNTED

Painted 1/8” aluminum panel with black reflective vinyl letters and graphics. Painted PVC clearance bar with applied vinyl graphics and lettering. Clearance bar to have end caps.

Aluminum frame is mechanically fastened to ceiling.

SIDE VIEW

SIDE VIEW

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

95STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 48: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Px-11b OVERHEAD CLEARANCEBEAM MOUNTED

Painted 1/8” aluminum panel with black reflective vinyl letters and graphics. Painted PVC clearance bar with applied vinyl graphics and lettering. Clearance bar to have end caps.

Aluminum frame is mechanically fastened to ceiling.

7'-0" Clearance

E N T R A N C E4'-7"

1'-0"

SIDE VIEW

6"

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3/4" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-11bOverhead Entrance/Clearance, Beam Mounted

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

96STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 49: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

ALTERNATE LAYOUTS

Elevators Elevators

SIDE VIEW

Elevators

3'-10"

10"

Px-12 OVERHEAD, PEDESTRIAN, SUSPENDEDPainted 1/8” aluminum panel with reflective vinyl letters and graphics.

Px-12a OVERHEAD, PEDESTRIAN, BEAM MOUNTEDPainted 1/8” aluminum panel with reflective vinyl letters and graphics.

SIDE VIEW

3'-10"

10" ElevatorsAluminum frame is mechanically fastened to ceiling.

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3/4" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-12, Px-12aOverhead Pedestrian

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

97STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 50: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

SIDE VIEW

ALTERNATE LAYOUTS

3'-10"

10" Elevators

Elevators Elevators Patient ParkingValet Parking

7"

8 1/4"4"

1’-0”

10 3/8"

3"

4 3/4"

Px-12b Painted 1/8” aluminum panel with reflective vinyl letters and graphics.

Aluminum frame is mechanically fastened to ceiling.

4" 7"7"

3"

3"

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3/4" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-12bOverhead Pedestrian

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

98STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 51: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

PORTLANDIA

PARKING GARAGE

ROOD PAVILION PARKING ONLY

STAFF PARKING ONLY

PATIENT & VISITOR PARKING

PORTLANDIA

PARKING GARAGE

PORTLANDIA

PARKING GARAGE

2 3/8"

1 1/2"2 3/4"

1 5/8"

3 7/8"3'-8"

4'-6"

4'-1 5/8"

2"

3 3/4" 3 3/8"

10 1/8"

1"

5 1/2"2 1/2"

4 1/2"

5 1/4"

1"

Px-14 ELEVATOR LEVEL IDENTIFIERSign is fabricated from two 1/8” (th.) painted aluminum panels. Graphics in the upper portion and lower black band are applied reflective vinyl with digitally printed graphics. Use exterior UV inks and graffiti resistant over-laminate. Silver rule lines are exposed background color. Sign panel flush mounted to wall with welded studs and silicone adhesive - no through face, or exposed mounting.

FONT:Gotham Condensed Medium.

TOP VIEW

ALTERNATE COLOR LAYOUT

ALTERNATE MESSAGE LAYOUTS

FONT:Gotham Condensed Medium.

FONT:Gotham Condensed Mediumkerning set @ 50%.

3/4" = 1'-0"(on an 11 x 17 sheet)

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-14 Elevator Level ID

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

99STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 52: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

GARAGE C

GARAGE A GARAGE B

GARAGE B GARAGE D GARAGE E

GARAGE F GARAGE B

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-14Elevator Level IDLayouts

LIGHTHOUSE

BRIDGE COAST

COAST

FALLS COAST

CRATER LAKE ROSE GARDEN

nts

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

100STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 53: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3/4" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-14aElevator Level ID, Small

P1LEVEL

LIGHTHOUSE

GARAGE C

3'-4 1/2"

2'-9"

Sign is fabricated from two 1/8” (th.) painted aluminum panels. Graphics in the upper portion and lower black band are applied reflective vinyl with digitally printed graphics. Use exterior UV inks and graffiti resistant over-laminate. Silver rule lines are exposed background color. Sign panel flush mounted to wall with welded studs and silicone adhesive - no through face, or exposed mounting.

FONT:Gotham Condensed Medium.

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

101STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 54: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

LIGHTHOUSE

Center for Health& Healing Garage

P1LEVEL

BUILDING

2'-9"

Sign is fabricated from two 1/8” (th.) painted aluminum panels. Entire face of sign is applied 3M™ 7930 Engineer Grade Prismatic reflective vinyl with digitally printed graphics to match specified color, Black and White. Use exterior UV inks and 3M™ 1170 Protective Overlay Film. Silver rule lines are exposed background color. Sign panel flush mounted to wall with welded studs and silicone adhesive - no through face, or exposed mounting.

FONT:Gotham Condensed Medium.

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3/4" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-14bElevator Level ID, Small(No Icon)

3'-9"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

102STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 55: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

LIGHTHOUSE

GARAGE C

LIGHTHOUSE

GARAGE C

LIGHTHOUSE

GARAGE C

Elevators

Elevators

LIGHTHOUSE

GARAGE C

Stairs

Stairs

LIGHTHOUSE

GARAGE C

Elevators

Valet Pickup

LIGHTHOUSE

GARAGE C

Doernbecher

LIGHTHOUSE

GARAGE C

EMERGENCY

Elevators

LIGHTHOUSE

GARAGE C

Valet Pickupon this Level

1'-10"

1'-10"

2'-4 1/2"

2'-9"

6'-8"

4'

Minimum mounting height

Maximum mounting height

Px-15b LEVEL IDENTIFIER - GUIDE (TWO LINES)

Px-15 LEVEL IDENTIFIERSign is fabricated from an 1/8” (th.) painted aluminum panel. Graphics in the upper portion of the sign are applied reflective vinyl with digitally printed graphics. Use exterior UV inks and graffiti resistant over-laminate. Footer consists of a painted black background and applied reflective vinyl lettering. Sign panel flush mounted to wall with welded studs and silicone adhesive - no through face, or exposed mounting.

FONT:Gotham Condensed Medium.

Px-15a LEVEL IDENTIFIER -GUIDE (ONE LINE)Guide information is reflective vinyl with painted background.

Alternate Layout Alternate Layout

Alternate LayoutAlternate Layout Alternate Layout

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3/4" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-15/15a/15bGarage Level ID

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

103STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 56: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

BRIDGE COAST

CRATER LAKE ROSE GARDEN

FALLS

LIGHTHOUSE COAST

P1LEVEL

P2LEVEL

P3LEVEL

P5LEVEL

P6LEVEL

P7LEVEL

P8LEVEL

GARAGE C GARAGE B GARAGE DP4LEVEL

GARAGE E

GARAGE A GARAGE B GARAGE F GARAGE F

COAST

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

01.31.18 Review

nts

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-15Garage Level IDLayouts

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

104STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 57: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

P4ParkingElevator

P2LEVEL

Guest HouseElevator

P2Building 2

Guest HouseElevator

Parking Elevator

Building

Building

Building 2

1'-10"

1'-10"

6'-8"

4'

Minimum mounting height

Maximum mounting height

Px-15d LEVEL IDENTIFIER - NO ICON - TWO LINESSign is fabricated from an 1/8” (th.) painted aluminum panel. Level identification is applied 3M™ 7930 Engineer Grade Prismatic reflective vinyl with digitally printed graphics. Guide information is reflective vinyl with painted background. Use exterior UV inks and 3M™ 1170 Protective Overlay Film. Sign panel flush mounted to wall with welded studs and silicone adhesive - no through face, or exposed mounting.

FONT:Gotham Condensed Medium.

Px-15e LEVEL IDENTIFIER -NO ICON - THREE LINES

Alternate Layouts

LEVEL

LEVELLEVEL

LEVEL

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3/4" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-15d/Px-15eGarage Level ID(No Icon, 2-3 Lines)

2'-5"

2'-3 1/2"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

105STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 58: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Skybridge to Sam Jackson, exit on Level 3.

COAST

PHYSICIANS PAVILION

To reach OHSU Hospital, exit on Level 1.

FALLS

GARAGE F

TEALLEVEL P5

YELLOWLEVEL P6

PURPLELEVEL P1

ORANGELEVEL P2

GREENBridge to DoernbecherLEVEL P3

REDLEVEL P4

BLUELEVEL P7

BROWNLEVEL P8

BROWNLEVEL P9

FLOOR 4

FLOOR 3

FLOOR 1

9"

1'-2"

Skybridge to Sam Jackson and OHSU Hospital

FLOOR 2

GARAGE B

TEALLEVEL P5

PURPLELEVEL P1

ORANGELEVEL P2

REDLEVEL P4

GREENLEVEL P3 Valet Pick-up

APCO FullView™ FVS1485(V)Large format printed insert with graphics TBD per project scope.

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-16Elevator Directory Level ID

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

106STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 59: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

3" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-16aElevator Directory Level IDLarge

Center for Health & Healing

Building 1

To access Building 1,exit on Floor 1 and

take the visitor elevator.

PURPLELEVEL P1

GREENLEVEL P3

ORANGELEVEL P2 Valet

Lobby & Street AccessFLOOR 1

March Wellness & Fitness CenterFLOOR 2

APCO FullView™ FVS1711(V)Large format printed styrene insert with graphics TBD per project scope.

11 1/2"

1'-5"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

107STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 60: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

ALTERNATE LAYOUT

ALTERNATE LAYOUTALTERNATE LAYOUT

ALTERNATE LAYOUT

ALTERNATE LAYOUT

ALTERNATE LAYOUT

3/4" = 1'-0"(on an 11 x 17 sheet)

Exit

PARKINGONE WAYTRAFFIC

9 1/8"

PARKINGONE WAYTRAFFIC

PARKING

EXIT

6 1/2"

3 7/8"

3 7/8"

3 7/8"

5 3/4"

3 1/8"

VALETDROP-OFF

FREE PATIENTPARKING

P4Exit

P6- P9Permit Parking

P1-P4Patient & Permit1'-6"

1'-2"

3'-0"

9"

9"

9"

7"

2 1/4"CL

9 1/4"

4 5/8"

3 1/8"1 3/8"3 1/8"

1 7/8"3/8"2"

2 1/4"1"

2 1/4"CL

9 1/4"

2 7/8"

6 1/2"

2 5/8"

Px-17Painted 1/8” aluminum panel with reflective vinyl letters and graphics. Sign panel flush mounted to wall with welded studs and silicone adhesive - no through face, or exposed mounting.

FONT:Gotham Condensed Mediumkerning set at 50%.

FONT:Gotham Condensed Mediumkerning set at 10%. ALL CAPITAL LETTERS.

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

Scale

Notes

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-17Vehicular GuideColumn Mounted

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

108STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 61: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

OHSU to confirm fabrication materials. Sign installed flush to wall, no through face, or exposed mounting.

FONT:Gotham Condensed Mediumkerning set at 25%.

top view

side view

Pay Stations AreLocated In The Lobby

Take Your TicketWith You

Pay Stations AreLocated In The Lobby

Take Your TicketWith You

1'-6"

2'-0"

8 5/8"

8 1/8"

5 1/2"

3/8"

1'-3"

2 1/8"

1 1/8"

1 1/16"

1 9/16"

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1 1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-18Remember Your Ticket

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

109STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 62: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

P8 - Permit

P7 - Permit

P6 - Permit

P5 - Permit

P4 - Metered Parking

P3 - Metered Parking

P2 - Patient & Visitor

P1 - Patient & Visitor

FP8 - Permit

P7 - Permit

P6 - Permit

P5 - Permit

P4 - Metered Parking

P3 - Metered Parking

P2 - Patient & Visitor

P1 - Patient & Visitor

F

FP1 - Patient & Visitor

P2 - Patient & Visitor

P3 - Patient & Visitor

P4 - Patient & Visitor

P5 - Patient & Visitor

1/8" thick surfaceapplied vinyl line

TOP VIEW TOP VIEW

Px-20 ELECTRONIC LEVEL SIGNPainted aluminum sign cabinet with cut-out pushed-through acrylic messaging. Sign is internally illuminated with white LED lighting. Sign is single-sided. Ground mounted. Individual electronic displays: Signal-Tech 7"x 18" Seven Segment Display.

ELECTRONIC COUNTER COMPONENTSAll details for required electronic components should

be verified with the parking electronics vendor before final sign fabrication. Back of sign must be

built so that internal components of the sign can be accessed for maintenance.

Px-20a ELECTRONIC LEVEL SIGNPainted aluminum sign cabinet with cut-out pushed-through acrylic messaging. Sign is internally illuminated with white LED lighting. Sign is single-sided. Wall mounted.

SIDE VIEW FRONT VIEW FRONT VIEWSIDE VIEWSIDE VIEW

ALTERNATE LAYOUT

88°

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

Electrical connection to be coordinated by fabricator and owner representative.

Mounting height to bedetermined

Final locations and wallconditions to be determined

Client

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

01.31.18 Review

Sign Type

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Px-20/Px-20aElectronic Sign

7"

4'-3"

3'-10 1/2" 4 1/2"2 3/4"

1'-0 3/4"

7"

1 5/8"

9 5/8"

1 5/8"2"

2 3/4"

2" 1"

eq6"

eq

6'-2 1/2"

8"

7'-1 1/2"

1'-5"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update

110STANDARDS MANUAL FOR WAYFINDING SIGNAGE

Page 63: KNIGHT CANCER INSTITUTE - OHSU › sites › default › files › 2018-10 › ... · Sign Type Ix-6a Individual Letters Client This drawing is design-intent only. ... with silver

This drawing is design-intent only.Fabricator is responsible for fabricationand overall level of quality. Any changesin design, materials, fabrication methodor other details must be approved byCorbin Design and Oregon Health & Science University.

1/2" = 1'-0"(on an 11 x 17 sheet)

Scale

Notes

Sign Type

Client

109 East Front Suite 304Traverse City, MI 49684

231 947.1236

Date Description

Rx-1/Rx-3Regulatory,Wall Mounted/Post Mounted

TOP VIEW

1'-6"

4"

4"1/2"

VanAccessible

AccessibleParking

ReservedParking

SPECIAL RESERVATIONREQUIRED AT ALL TIMES

Unauthorized vehicles willbe ticketed and towed at

owners expense.

ReservedParking

SPACE #14KSPECIAL PERMIT

REQUIRED AT ALL TIMES

Unauthorized vehicles will be ticketed and towed at

owners expense.

ReservedParking

EmergencyParking Only

ReservedParking

PhysiciansOnly

ReservedParking

PhysiciansOnly

ReservedParking

PhysiciansOnly

No Entry Patient drop-off only, please.

WheelchairUser Only

AccessibleParkingNo Parking

P

FOUNDATION AND MOUNTING TOBE ENGINEERED BY FABRICATOR

Rx-1 FRONT VIEW

ALTERNATE LAYOUTS

Rx-1 SIDE VIEW Rx-3 FRONT VIEW Rx-3 BACK VIEW Rx-3 SIDE VIEW

Concrete foundation cylinder

1/8" thick aluminum panel with engineer grade reflective white background. Mounted to wall with bolts through sign face.

Surface appled opaque vinyl graphics.

PANEL ATTACHMENTPanels bonded to painted aluminum “L” channel brackets. Brackets are attached to post with round head screws.

082" square aluminum post

MOUNTING TO BEENGINEERED BY FABRICATOR

1'-0"

1'-6"

05

07

08

08

3 1/8"2"

1 3/8"2"

3 3/8"

1/4" rule line

1 3/8"3/4"3/4"

1/8” thick painted aluminum panel.

Approximatley 4'-6"above grade

6'-0"

08.30.13 Design Intent10.21.13 Revised05.03.18 Branding Update