PA 605 Purifier System Installation System Reference Printed Book No. Dec 2005 577217-02 Rev. 2

Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

  • Upload
    hahanh

  • View
    234

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 Purifier System

Installation System Reference

Printed

Book No.

Dec 2005

577217-02 Rev. 2

Page 2: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

roduced or written

Published By:Alfa Laval Tumba AB SE-147 80 Tumba, Sweden

Telephone: +46 8 530 650 00 Telefax: +46 8 530 310 40

© Alfa Laval Tumba AB 1 December 2005

This publication or any part there of may not be reptransmitted by any process or means without prior permission of Alfa Laval Tumba AB.

Page 3: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

Contents

1 Technical Data ......................................5

1.1 Demand Specifications Water .....5

1.2 Demand Specifications Air ...........5

1.3 System Data .....................................6

2 Drawings....................................................92.1 Flow Chart ..........................................9

2.2 Drawings ...........................................102.2.1 P 605 Separator Mounting Drawing,

DIN .......................................................10

2.2.2 P 605 Separator with Sludge Removal Kit Mounting Drawing, DIN .......................................................11

2.2.3 P 605 Separator Mounting Drawing, JIS.........................................................12

2.2.4 P 605 Separator with Sludge Removal Kit Mounting Drawing, JIS.........................................................13

2.2.5 P 605 Separator Basic Size Drawing ................................................14

2.2.6 P 605 Separator Foundation Drawing ................................................15

2.2.7 Valve Block Water Dimension Drawing ................................................16

2.2.8 Control Unit EPC 50 Dimension Drawing ................................................17

2.2.9 Starter Dimension Drawing...................18

2.3 Electrical System Layout ...........192.4 Electrical Diagrams .......................20

2.4.1 Cable List ............................................20

2.4.2 Interconnection Diagram, Starter ........232.4.3 Interconnection Diagram, Starter,

cont. .....................................................24

2.4.4 Interconnection Diagram, Transmitters..........................................25

2.4.5 Interconnection Diagram, Solenoid Valves ..................................................26

2.4.6 Interconnection Diagram, Solenoid Valves cont. ..........................................27

2.4.7 Interconnection Diagram, Optional Equipment ............................................28

2.4.8 Circuit Diagram, Power Circuits ...........29

2.4.9 Circuit Diagram, Separator Starter and Feed Pump ...................................30

2.4.10 Circuit Diagram, ESD-relay and Trip Contacts (optional) ...............................31

3 Remote Supervision........................33

4 Specifications .....................................354.1 Cables ................................................35

4.2 Cable Routing ..................................364.3 Oil, Water, Steam, and

Condensate Piping .........................36

4.4 Ambient Temperature Limitation ..........................................37

4.5 Sludge Tank .....................................374.6 Sludge Piping ...................................39

5 Commissioning and Initial Start ...........................................................415.1 Completion Check List .................41

5.2 Initial Start-up .................................43

5.2.1 Calculating Operating Pressure ...........45

6 Shut-down and Storage ................476.1 Shut-down after Use......................47

6.2 Protection and Storage ................486.3 Reassembly and Start up.............49

577217-02

Page 4: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

577217-02

Page 5: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1 TECHNICAL DATA

1 Technical Data

1.1 Demand Specifications WaterAlfa Laval ref. 574487 rev. 0

1.2 Demand Specifications AirSpecific requirements regarding the quality of air

1 Pressure 500 – 700 kPa.

2 Free from oil, and solid particles larger than 0.01 mm.

3 Dry, with dew point min. 10 °C below ambient temperature.

NOTE

Electrical interconnections must be made by qualified electricians.Mechanical interconnections must be made by qualified mechanical technicians.

Poor quality of the operating water may with time cause erosion, corrosion and/or operating problems. The water shall be treated to meet certain demands.

The following requirements are of fundamental importance:

1 Turbidity-free water, solids content <0,001% by volume. Max. particle size 50 µm. Deposits shall not be allowed to form in certain areas in the system.

2 Total hardness less than 180 mg CaCO3 per litre, which corresponds to 10 °dH or 12,5 °E. Hard water may with time form deposits in the operating mechanism. The precipitation rate is accelerated with increased operating temperature and low discharge frequency. These effects become more severe the harder the water is.

3 Chloride content max. 100 ppm NaCl (equivalent to 60 mg Cl/l). Chloride ions contribute to corrosion on surfaces in contact with the operating water.Corrosion is a process that is accelerated by increased separating temperature, low pH, and high chloride ion concentration.

4 6,5 < pH < 9 Bicarbonate content (HCO3) min. 70mg HCO3 per litre, which corresponds to 3,2 °dKH.

NOTE

Alfa Laval accepts no liability for consequences arising from unsatisfactorily purified operating water supplied by the customer.

577217-02 5

Page 6: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

1 TECHNICAL DATA PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

uel oil and lube oils for diesel engines

91 kg/m³ at 15 °C

0 cSt at 100 °C (600 cSt at 50 °C)

ax. 4 bar

ax. delivery height 2.5 bar

pen outlet

pen outlet

00 °C

in. +5 °C, max. +55 °C

in 2 bar, max. 6 bar

in. +5 °C, max. +55 °C (unheated water)

ax. 1000 kg/m³

o SV10: 8.0 l/m

o SV 15: 18 l/m

o SV 16: 0.9 l/m

nstrument air

in. 5 bar, max. 7 bar

.1 litre

/4”

x400/440/480 V ± 10%

30 V /110V/115 V/100V ± 10%, 10 A

4 V AC

0 or 60 Hz ± max. 5%

ax. 55 °C

0 m

months

in. +0 °C, max. +70 °C

elative humidity (RH) 10% – 95 % Non Condensing

in. IP 54

ote! Regularly check connections. Tighten if necessary.

nspection every 2000 hours or 3 months operation

verhaul every 8000 hours or 12 months operation

1.3 System Data

Media F

Feed density, max. 9

Viscosity, max. 5

Pressure:

Oil inlet

Oil outlet

Sludge outlet from separator

M

M

o

Water outlet o

Feed temperature, max. 1

Ambient temperature M

Operating water pressure M

Operating water temp. M

Operating water density M

Operating water flow t

t

t

Air quality I

Air pressure M

Discharge volume 1

Separator drain connection size 3

Mains supply voltage 3

Power consumption, control voltage; EPC supply voltage

2

Control voltage, operating 2

Frequency 5

Ambient temperature M

Control cabinet max. distance from unit 5

Storage time before use (with bowl removed) 6

Storage temp. M

Storage humidity R

Enclosure class M

Service intervals: N

Separator I

O

6 577217-02

Page 7: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1 TECHNICAL DATA

ce Kits

Ancillary Equipment

Repair

(components)

Separation System Planned Maintenan

Hours Period Separator

1000

2000

4000 6 months Inspection

12000 18 months Overhaul

24000 3 years Overhaul

As necessary

With delivery Inspection

Tools

577217-02 7

Page 8: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

1 TECHNICAL DATA PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

8 577217-02

Page 9: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

2 Drawings

X0

23

36

1D

2.1 Flow Chart

201 Oil inlet

206 Water for water seal and displacement

209 Oil Recirculation to tank

220 Clean oil outlet

221 Water outlet

Optional Alfa Laval delivery

Block mounted

Not included in Alfa Laval standard delivery

Starter

Control unit

Drain

Flow Control

Hea

ting

syst

em

222 Sludge discharge outlet

371 Operating water

372 Opening water

373 Closing water

462 Drain, lower

463 Drain, upper

501 Operating air

540 Ventilation

Tank

SRK

Alt.

Ref. 576791 Rev. 1

577217-0

2 9
Page 10: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

X0

23

85

3A

10 577217-02

2.2 Drawings

2.2.1 P 605 Separator Mounting Drawing, DIN

A

Ref. 576840 Rev. 2

Co

nn

ec

tio

ns

AF

lang

e D

N25

-PN

16-D

IN26

33

BF

lang

e D

N50

-PN

6-D

IN26

33

CW

ater

pip

e co

nnec

tion

IS

O-G

1/2

siz

e

DA

ir pi

pe c

onne

ctio

n

ISO

-G 1

/4 s

ize

*In

tern

al fl

exib

le c

onne

ctio

n (e

nclo

sed

with

Alfa

Lav

al

deliv

ery)

N

ot

incl

uded

in

A

lfa

L

aval

del

iver

y

Opt

iona

l Alfa

Lav

al

de

liver

y

201

Oil

inle

t

206

Wat

er fo

r se

al a

nd d

ispl

acem

ent

209

Oil

reci

rcul

atio

n to

tank

220

Cle

an o

il ou

tlet

221

Wat

er o

utle

t

222

Slu

dge

outle

t

371

Ope

ratin

g w

ater

- s

ee 1

.1

Dem

and

Spe

cific

atio

n W

ater

.P

ress

ure

200-

600

kPa

(2-6

bar

).Te

mp.

min

+5°

C, m

ax. +

55°C

372

Ope

ning

wat

er

373

Clo

sing

wat

er

501

Ope

ratin

g ai

r. pr

essu

re 5

00-7

00 k

Pa

(5-7

bar

).

540

Ven

tilat

ion

709

Mai

ns s

uppl

y: 3

x230

/400

/440

/48

0/57

5/69

0 V

AC

799

EP

C s

uppl

y vo

ltage

: 230

,110

/11

5V o

r 10

0V A

C

(0-6

bar

) P

ress

ure

gaug

e

(-1/

+1,

5 ba

r)

Vac

uum

ga

uge

Slu

dge

tank

(0-6

bar

) P

ress

ure

gaug

eD

etai

l

(If B

V m

ount

ed)

95

Fee

d pu

mp

Hea

ting

syst

em

(0-1

20 °

C)

Tem

pera

ture

In

dica

tor

Sta

rter

EP

C 5

0

Det

ail A

Page 11: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

X0

23

85

6A

2.2.2 P 605 Separator with Sludge Removal Kit Mounting Drawing, DIN

A

A

Ref. 578194 Rev. 0

Co

nn

ec

tio

ns

AF

lang

e D

N25

-PN

16-D

IN26

33

CW

ater

pip

e co

nnec

tion

IS

O-G

1/2

siz

e

DA

ir pi

pe c

onne

ctio

n

ISO

-G 1

/4 s

ize

EV

entil

atio

n pi

pe 2

” si

ze

*In

tern

al fl

exib

le c

onne

ctio

n (e

nclo

sed

with

Alfa

Lav

al

deliv

ery)

N

ot

incl

uded

in

A

lfa

L

aval

del

iver

y

Opt

iona

l Alfa

Lav

al

de

liver

y

201

Oil

inle

t

206

Wat

er fo

r se

al a

nd d

ispl

acem

ent

209

Oil

reci

rcul

atio

n to

tank

220

Cle

an o

il ou

tlet

221

Wat

er o

utle

t

222

Slu

dge

outle

t

371

Ope

ratin

g w

ater

- s

ee 1

.1

Dem

and

Spe

cific

atio

n W

ater

.P

ress

ure

200-

600

kPa

(2-6

bar

).Te

mp.

min

+5°

C, m

ax. +

55°C

372

Ope

ning

wat

er

373

Clo

sing

wat

er

501

Ope

ratin

g ai

r. pr

essu

re 5

00-7

00 k

Pa

(5-7

bar

).

540

Ven

tilat

ion

709

Mai

ns s

uppl

y: 3

x230

/400

/440

/48

0/57

5/69

0 V

AC

799

EP

C s

uppl

y vo

ltage

: 230

,110

/11

5V o

r 10

0V A

C

(0-6

bar

) P

ress

ure

gaug

e

(-1/

+1,

5 ba

r)

Vac

uum

ga

uge

(0-6

bar

) P

ress

ure

gaug

e

Det

ail

Fee

d pu

mp

Hea

ting

syst

em

(0-1

20 °

C)

Tem

pera

ture

In

dica

tor

Sta

rter

EP

C 5

0

Det

ail

577217-02 11

Page 12: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

X0

23

85

4A

2.2.3 P 605 Separator Mounting Drawing, JIS

Ref. 576841 Rev. 2

(0-6

bar

) P

ress

ure

gaug

e

(-1/

+1,

5 ba

r)

Vac

uum

ga

uge

Slu

dge

tank

(0-6

bar

) P

ress

ure

gaug

eD

etai

l

(If B

V m

ount

ed)

95

Fee

d pu

mp

Hea

ting

syst

em

(0-1

20 °

C)

Tem

pera

ture

In

dica

tor

Sta

rter

EP

C 5

0

Co

nne

cti

on

s

AF

lang

e JI

S 2

5A 1

0K

BF

lang

e JI

S 5

0A 1

0K

CW

ater

pip

e co

nnec

tion

ISO

G-1

/2 s

ize

DA

ir pi

pe c

onne

ctio

n

ISO

G-1

/4 s

ize

*In

tern

al fl

exib

le c

onne

ctio

n (e

nclo

sed

with

Alfa

Lav

al

deliv

ery)

N

ot

incl

uded

in

A

lfa

L

aval

del

iver

y

Opt

iona

l Alfa

Lav

al

de

liver

y

201

Oil

inle

t

206

Wat

er fo

r se

al a

nd d

ispl

acem

ent

209

Oil

reci

rcul

atio

n to

tank

220

Cle

an o

il ou

tlet

221

Wat

er o

utle

t

222

Slu

dge

disc

harg

e ou

tlet

371

Ope

ratin

g w

ater

- s

ee 1

.1

Dem

and

Spe

cific

atio

n W

ater

.P

ress

ure

200-

600

kPa

(2-6

bar

).Te

mp.

min

+5°

C, m

ax. +

55°C

372

Ope

ning

wat

er

373

Clo

sing

wat

er

501

Ope

ratin

g ai

r. pr

essu

re 5

00-7

00 k

Pa

(5-7

bar

).

540

Ven

tilat

ion

709

Mai

ns s

uppl

y: 3

x230

/400

/440

/48

0/57

5/69

0 V

AC

799

EP

C s

uppl

y vo

ltage

: 230

,110

/11

5V o

r 10

0V A

C

12 577217-02

Page 13: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

X0

23

85

5A

2.2.4 P 605 Separator with Sludge Removal Kit Mounting Drawing, JIS

Ref. 578193 Rev. 0

(0-6

bar

) P

ress

ure

gaug

e

(-1/

+1,

5 ba

r)

Vac

uum

ga

uge

(0-6

bar

) P

ress

ure

gaug

eD

etai

l

Fee

d pu

mp

Hea

ting

syst

em

(0-1

20 °

C)

Tem

pera

ture

In

dica

tor

Sta

rter

EP

C 5

0

Co

nn

ec

tio

ns

AF

lang

e JI

S 2

5A 1

0K

CW

ater

pip

e co

nnec

tion

ISO

G-1

/2 s

ize

DA

ir pi

pe c

onne

ctio

n

ISO

G-1

/4 s

ize

EV

entil

atio

n pi

pe 2

” si

ze

*In

tern

al fl

exib

le c

onne

ctio

n (e

nclo

sed

with

Alfa

Lav

al

deliv

ery)

N

ot

incl

uded

in

A

lfa

L

aval

del

iver

y

Opt

iona

l Alfa

Lav

al

de

liver

y

201

Oil

inle

t

206

Wat

er fo

r se

al a

nd d

ispl

acem

ent

209

Oil

reci

rcul

atio

n to

tank

220

Cle

an o

il ou

tlet

221

Wat

er o

utle

t

222

Slu

dge

disc

harg

e ou

tlet

371

Ope

ratin

g w

ater

- s

ee 1

.1

Dem

and

Spe

cific

atio

n W

ater

.P

ress

ure

200-

600

kPa

(2-6

bar

).Te

mp.

min

+5°

C, m

ax. +

55°C

372

Ope

ning

wat

er

373

Clo

sing

wat

er

501

Ope

ratin

g ai

r. pr

essu

re 5

00-7

00 k

Pa

(5-7

bar

).

540

Ven

tilat

ion

709

Mai

ns s

uppl

y: 3

x230

/400

/440

/48

0/57

5/69

0 V

AC

799

EP

C s

uppl

y vo

ltage

: 230

,110

/11

5V o

r 10

0V A

C

577217-02 13

Page 14: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

X0

23

36

4A

2.2.5 P 605 Separator Basic Size Drawing

Ref. 565297 Rev. 2

Con

nect

ion

201

and

220

turn

able

90°

All

conn

ectio

ns to

be

inst

alle

d n

on-

load

ed a

nd fl

exib

le

Max

imum

ver

tical

d

isp

lace

men

t at t

he s

olid

p

hase

out

let c

onne

ctio

n d

urin

g

oper

atio

n ±

10

mm

Max

imum

hor

izon

tal

dis

pla

cem

ent a

t the

in

let/

outle

t con

nect

ions

d

urin

g o

per

atio

n ±

20

mm

All

dim

ensi

ons

are

nom

inal

. R

eser

vatio

n fo

r in

div

idua

l d

evia

tions

due

to to

lera

nces

.

14 577217-02

Page 15: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

2.2.6 P 605 Separator Foundation Drawing

Min. lifting capacity required when doing service: 300 kg

Recommended free floor space for unloading when doing service.

No fixed installation within this area

Centre of gravity (complete machine)

Total static load max. 4 kN

Vertical force not exceeding 5 kN/foot

Max. height of largest component incl. lifting tool.

Horizontal force not exceeding 7 kN/foot

Centre of separator bowl

8 holes for foundation bolts

Centre of motor

Ref. 548711 Rev. 2

X0

23

36

5A

577217-02 15

Page 16: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

X0

23

36

7A

2.2.7 Valve Block Water Dimension Drawing

Ref. 1765927 Rev. 9

Con

nect

or is

not

del

iver

ed w

ith

artic

le n

o.

Hos

e le

ngth

- 1

050

mm

Del

iver

ed w

ith v

alve

blo

ck:

Hos

e fa

sten

ers

- 4

pcs

Fla

t pin

con

nect

ion

Iden

tific

atio

n la

bel

sym

bol:

Dra

in

Tec

hn

ica

l D

ata

Med

iaFr

esh

wat

er m

ax. 1

0 °d

H

Med

ia te

mp.

min

. 5 °

C –

max

55

°C

Wat

er p

ress

ure

200

– 60

0 kP

a (2

– 6

bar

)

Am

bien

t tem

pera

ture

min

10

°C –

max

55

°C

Mat

eria

lB

ody

– br

ass

Res

ilien

ts –

NB

R (

Bun

a-N

)

Ele

ctric

al d

ata

Pow

er c

onsu

mtio

nE

lect

ric c

onne

ctio

nC

able

con

nect

ion

Enc

losu

re

6W –

9W

acc.

to D

IN 4

3 65

0-A

Pg

11 (

for

cabl

e ∅

9 –

∅11

)IP

65

Mou

ntin

g st

yle

Upr

ight

as

show

n

Wei

ght

2.8

kg

16 577217-02

Page 17: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

X0

23

36

9C

2.2.8 Control Unit EPC 50 Dimension Drawing

Operating panel

Separator interlock indication (optional) Emergency stop,

separator

On-off, feed pump

Plugged holes for extra cable glands

Sludge valve interlock indication (optional)

On-off, separator

Technical Data

Ambient temperature Max. 55 °C

Protection class IP 65

Material in cabinet Sheet steel

Power supply 100,115, or 230 V AC 50/60 Hz

Operating voltage 24 v AC 50/60 Hz

Power consumption 70 VA (+200 VA for I/O)

Weight 19 kg

Optional

Ref. 568304

577217-02 17

Page 18: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

X0

23

37

0A

2.2.9 Starter Dimension Drawing

Technical Data

Mains supply 3x230, 400, 440, 480, 575, 690 V AC Max fuse 40 A

Current ranges Acc. to order (for separator 2.5 – 16 A and for pump 0.4 – 10 A)

Power supply to EPC 230 V, 300 VA

Weight 25 – 30 kg

Ref. 571340 Rev. 0

18 577217-02

Page 19: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

X0

23

85

7A

2.3 Electrical System Layout

Ref. 576789 Rev. 1

Op

tiona

l Alfa

Lav

al

del

iver

y

Func

tiona

l blo

cks

Sep

. int

erlo

ck S

witc

h

Circ

uit b

oar

ds

–Com

mun

icat

ion

–Hea

ter

cont

rol

–Rem

ote

alar

ms

Fee

d pu

mp

Rem

ote

OP

uni

t

Rem

ote

Sta

rt/S

top

Dat

a

Sys

tem

C

omm

.

Em

erg

ency

SU

M

Ala

rm

Tem

p. A

l.

Rem

ote

Sta

rter Mains supply

Hea

ting

syst

em

See

als

o fo

r:el

ectr

ic h

eate

r 17

6586

7 st

eam

hea

ter

1765

868

Con

trol

uni

t

Tank

Slu

dge

pum

p

SR

K

577217-02 19

Page 20: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

2.4 Electrical Diagrams

2.4.1 Cable List

Ref. 571356 Rev. 1

No. Type Connection point A

Instruction Connection point B

Remarks

Power cables (currents according to order)

1 MPRXCX 3x4 Mains supply Starter Fuse 20 A

1 MPRXCX 3x10 Mains supply Starter Fuse 35 A

2 MPRXCX 2x1.5 Starter EPC 50

3 MPRXCX 3x1.5 Starter Separator motor 2.5 – 6.3 A

3 MPRXCX 3x2.5 Starter Separator motor 6.3 – 16 A

71 MPRXCX 2x1.5 Starter Separator motor

4 MPRXCX 3x1.5 Starter Feed pump 0.4 – 6.3 A

4 MPRXCX 3x2.5 Starter Feed pump 6.3 – 10 A

72 MPRXCX 2x1.5 Starter Feed pump

20 577217-02

Page 21: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

h

No. Type Connection point A

Instruction Connection point B

Remarks

Signal cables

11 RFE-HF 1x2x0.75 EPC 50 SV1

14 RFE-HF 1x2x0.75 EPC 50 SV10

15 RFE-HF 1x2x0.75 EPC 50 SV15

16 RFE-HF 1x2x0.75 EPC 50 SV16

17 RFE-HF 1x2x0.75 EPC 50 SSC PT1

18 RFE-HF 1x2x0.75 EPC 50 SSC PT4

22 RFE-HF 1 x2x0.75 EPC 50 SUM Alarm

23 RFE-HF 4x2x0.75 EPC 50 SSC TT1/TT2

50 RFE-HF 4x2x0.75 EPC 50 Starter

51 RFE-HF 4x2x0.75 EPC 50 Starter

52 RFE-HF 1 x4x0.75 EPC 50 Starter

Options (as ordered)

25 (PVC 5GO.75) Starter SS, Sep.Switch Included in separator switc

30 RFE-HF 1 x4x0.75 EPC 50 YS, Vibr.Switch

31 RFE-HF 1 x4x0.75 EPC 50 SSC+EMC Rem. OP Unit

32 RFE-HF 1 x4x0.75 EPC 50 Rem. Temp. al.

33 MPRXCX 5x1.5 EPC 50 Rem. Start/stop

34 RFE-HF 1 x4x0.75 EPC 50 SSC+EMC Comm. Module

35 RFE-HF 1 x4x0.75 Starter GS, Valve Switch

36 RFE-HF 1 x2x0.75 EPC 50 LS, Sludge Level

37 RFE-HF 1 x2x0.75 EPC 50 SV6, Sol. Valve For pneumatic sludge pump

38 MPRXCX 4x1.5 EPC 50 Syst.Emergency 1)

40 RFE-HF 4x2x0.75 EPC 50 Power Unit

45 RFE-HF 1 x2x0.75 Starter Power Unit

41 RFE-HF 1 x4x0.75 EPC 50 Steam Reg. Val

44 RFE-HF 1 x2x0.75 EPC 50 Shut-off Valve

1) Cable cannot be longer than 25 meter to avoid voltage drop.Ref. 571356 Rev. 1

577217-02 21

Page 22: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

Other equivalent and approved cables may be used.

Cable areas are calculated with correction factor 0.7.

Cables used are Shipboard Cables, designed according to IEC 92-3.

Flame retardant according to IEC 332-3/A.

Halogen-free according to IEC 754-1

Code designations for cables obtainable through cable producers Helkama, Finland, and Acatel, France.

Where SSC is indicated it should be a Signal Shielded Cable with the shield properly connected to earth as shown in the electrical drawings.

For other connections, an armoured cable may be used provided the armour is connected to earth, as shown in the electrical drawings, and gives sufficient EMI protection. Copper wire armouring is normally used.

22 577217-02

Page 23: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

X0

23

37

2A

2.4.2 Interconnection Diagram, Starter

Ref. 571072 Rev. 1 Sheet 1

Mains suppy3x230,400, 440, 480, 575 or 690 V AC

Space heater 230 VAC Separator motoroptional

Systems emergency stop (Control voltage off)

230 V AC, 50/60 HzPower supply to EPC 50 (Sheet 5)

Separator motor

Select correct voltage on transformer T8

Contactor response, separator

Potential free contacts, max. 250 V 0.5 A

Feed pump motor optional

Space heater 230 VAC Separator motoroptionalContactor response, separator

Potential free contacts, max. 250 V 0.5 A

ES

D-relay option,

sheet 2

STA

RTE

R

577217-02 23

Page 24: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

X0

23

37

3A

2.4.3 Interconnection Diagram, Starter, cont.

Ref. 571072 Rev. 1 Sheet 2

To EPC 50 (sheet 5)

To EPC 50 (sheet 5)

Separator emergency stop (optional, external)

Sludge valve interlock switch optional

Remote stop

Remote startFeed pump

Feed pump interlock

Heater interlockPotential free contact, max. 250 V 0.5 A(Feed pump running = contact closed)Tripped motor circuit breakers (optional)

Potential free NC contacts, max. 250 V 0.5 A

Emergency Shut Down (ESD) feedback (optional)

* = Replaces jumper in terminals** = Internal connections

Emergency Shut Down (ESD) signal (optional)

Separator interlock switch optional

To EPC 50 (sheet 3)

STA

RTE

R

24 577217-02

Page 25: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

X0

23

85

8A

2.4.4 Interconnection Diagram, Transmitters

Sheet 4

Internal connections

Internal connections

CO

NTR

OL U

NIT E

PC

50

Note!

Sheet 4 X

7.5(for option X

S1)

Heater board

Optional

PT1

Temp. sensor, 2xPT 100

TT 1 (Alarm)

XS 1Vibration switchOptional

TT 2 (Control)

* Termination jumper. Only at sattbus end units.

Remote OP unit

PT4

From Starter (Sheet 2)

LSLevel Switch Sludge Tank (Optional)

Ref. 571072 Rev. 1 Sheet 3

577217-02 25

Page 26: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

X0

23

85

9A

2.4.5 Interconnection Diagram, Solenoid Valves

Signal to alarm panel.Pot. free contact, opens at alarm

Max. 50 V AC/DC, 1.0 A

SV1 Oil feed

SV10Water seal

SV16Closing water

SV15Opening water

CO

NTR

OL U

NIT E

PC

50P

reset internal connection to S

1

Internal connections

SV6 Solenoid valve for control of Pneumatic Sludge Pump(Optional)

Sheet 3

Sheet 3

Ref. 571072 Rev. 1 Sheet 4

26 577217-02

Page 27: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

2.4.6 Interconnection Diagram, Solenoid Valves cont.

X0

23

37

6A

Ref. 571072 Rev. 1 Sheet 5

Systems emergency stop (Control voltage off)

From starter (sheet 2)

From starter (sheet 2)

From starter (sheet 1)

Jump

ers at 100 V A

C

Jump

ers at 110/115 V A

C

Jump

ers at 230 V A

C

24 V p

hase24 V

neutral

Connections for alternative

voltages

577217-02 27

Page 28: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

X0

23

37

7A

2.4.7 Interconnection Diagram, Optional Equipment

Ref. 571072 Rev. 1 Sheet 6

Remote operation

Remote mode selected (output 24 V AC)Sep. status indication (output 24 V AC)Separation Start/Stop

NoteJumper X71:1 to X71:3 to avoid false alarm when not used.

Data communication

StartStop

Low temp. indicationPot. free contacts Max. 50 V AC/DC, 1.0 A Contact closes at alarm.

High temp. indication

Remote alarm indication

Bus GND

Line BShield

Line A

CO

MM

. BO

AR

DH

EAT

ER

BO

AR

DI/O

-EX

PAN

SIO

N B

OA

RD

CO

NTR

OL U

NIT E

PC

50

For elecrtric heater see 1765867For steam

heater see 1765868

28 577217-02

Page 29: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

X0

19

24

8A

2.4.8 Circuit Diagram, Power Circuits

Mains supply

Separator

Space heater(optional)

Feed pump(optional)

Space heater(optional)

Cont.

Ref. 571073 Rev. 1 Sheet 1

577217-02 29

Page 30: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

X0

19

24

9A

2.4.9 Circuit Diagram, Separator Starter and Feed Pump

Ref. 571073 Rev. 1 Sheet 2

CO

NTA

CTO

R,

SE

PAR

ATO

RS

TAR

T S

EPA

RAT

OR

SE

PAR

ATO

R F

EE

DB

AC

K

STA

RT

FE

ED

PU

MP

FE

ED

PU

MP

FE

ED

BA

CK

PIL

OT

LA

MP,

S

EPA

RAT

OR

CO

NTA

CTO

R, F

EE

D

PU

MP

PIL

OT

LA

MP,

FE

ED

P

UM

P

SLU

DG

E V

ALV

E IN

DIC

ATIO

N

Opt

iona

l

SE

PAR

ATO

R

INT

ER

LOC

K

SW

ITC

H

(Opt

iona

l)

SLU

DG

E

VA

LVE

IN

TE

RLO

CK

S

WIT

CH

(O

ptio

nal)

EM

ER

GE

NC

Y S

TOP

(R

emot

e in

dica

tion)

(R

emot

e in

dica

tion)

SE

PAR

ATO

R IN

TE

RLO

CK

IN

DIC

ATIO

N

Opt

iona

l

30 577217-02

Page 31: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS

X0

19

25

0A

2.4.10 Circuit Diagram, ESD-relay and Trip Contacts (optional)

Ref. 571073 Rev. 1 Sheet 3

ESD relay kit(optional)

Trip contact kit(optional)

577217-02 31

Page 32: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

2 DRAWINGS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

32 577217-02

Page 33: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 3 REMOTE SUPERVISION

3 Remote Supervision

NOTE

It is possible to supervise the Purifier System from a remote position. It is, however, not possible to operate the Purifier System from a remote position.

Connection to steering system via PROFIBUS or MODBUS fieldbus systems.

PROFIBUS or MODBUS communication protocol can be used to connect an EPC 50 Control Unit to a central steering system. The EPC 50 Control Unit uses a PROFIBUS DP or MODBUS RTU. Every node, or EPC 50 Control Unit, on the bus has a unique address, and can use 200 bytes for data exchange. An interface board is needed to connect an EPC 50 Control Unit to the respective fieldbus system. This is mounted on the I/O card.

Remote fieldbus connection for EPC 50 Control Unit is for use in those cases where the user wants access to data and operation information from the control cabinet, and supervision and/or remote control from his own steering system.

577217-02 33

Page 34: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

3 REMOTE SUPERVISION PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

Alternative PROFIBUS MODBUS

User interface To be arranged by customer.

To be arranged by customer.

Cable Cable for PROFIBUS aquired and installed by customer.

Cable for MODBUS aquired and installed by customer.

Manual Hardware and software instructions exist.

Hardware and software instructions exist.

Board Part no. 31830-6559-1 Part no. 31830-6558-1

34 577217-02

Page 35: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 4 SPECIFICATIONS

G0

32

22

4A

G0

32

24

4A

G0

32

21

4A

G0

32

23

4A

4 Specifications

4.1 Cables

Cable Identification

All cables are marked to simplify identification and fault finding.

Specifications

The following specifications apply to cables connected to and from Alfa Laval equipment.Follow the instructions given in the cable list.Examples of cable types that can be used:

• Steel armoured cable.

• Copper armoured cable with a separate earth core.

• Steel armoured and shielded signal cable; pair twisted or parallel.

• Shielded signal cable; pair twisted or parallel.

577217-02 35

Page 36: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

4 SPECIFICATIONS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

S0

02

89

1A

G0

32

27

3A

4.2 Cable Routing

4.3 Oil, Water, Steam, and Condensate PipingFor piping to and from Alfa Laval equipment, see the specifications below.

Specifications

• The correct pipe size must be used in the oil system.

• The number of bends in the oil pipes must be minimized.

• The suction height must be as low as possible.

• The oil feed pump must be a displacement type pump.

• The pump must be positioned close to the oil tank.

• The heater must be installed close to the purifier unit to maintain correct feed oil temperature.

• The recirculation line should be connected either directly to the settling tank (HFO) or to the oil outlet line from the separator (LO).

• The oil outlet line from the separator must be connected to the system tank for lube oil, or the service tank for fuel oil.

Recommendations

Power cables carry the power supply to motors, heaters, etc.Any distance between signal and power cables reduces electrical noise transfer.

Examples of recommended routing of various cable types.

• Power cables and signal cables routed on a cable rack should be separated.

• Sattbus cables should be routed away from power cables.

If the space is limited, cables can be routed in tubes.

Power Cables

Signal Cable

36 577217-02

Page 37: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 4 SPECIFICATIONS

G0

04

27

3A

G0

04

27

4A

4.4 Ambient Temperature Limitation

4.5 Sludge Tank

Specification

Leading classification societies state in their regulations for engine room equipment that the maximum ambient temperature permissible is +55 ° C. To meet this regulation, it is essential that electrical and electronic components have good ventilation, ant temperature control.

• Sludge tank volume per Purifier System should cover approximately up to 2 days storage at a discharge interval of 2 hours (for discharge volumes see technical data).

• A manhole should be installed for inspection and cleaning.

• The tank should be fitted with a sounding pipe.

• The tank floor, or most of it, should have a slope of minimum 15°.

• The sludge outlet pump connection should be positioned in the lowest part of the tank.

• A high level alarm switch, connected to the sludge pump, should be installed.

• A heating coil should be used to keep the sludge warm and fluid while being pumped out.

• Tank ventilation must follow the classification rules for evacuation of gases.

• There should be a ventilation pipe to fresh air.

• The ventilation pipe should be straight. If this is not possible, any bends must be gradual.

• The ventilation pipe must not extend below the tank top.

• A sludge tank with partition walls must have ventilation pipes in all compartments, or cutouts in the upper edge, to allow vapours to travel through the tank.

Sludge outlet pump connection

Min. height 400 mm

Ventilation pipe

Sludge pipe connection

Min. slope 15°

Manhole High level alarm switch

Heating coil

577217-02 37

Page 38: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

4 SPECIFICATIONS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

The number of ventilation pipes, and their minimum dimension, depend on the size and number of separators connected to the same tank. See table below.

Type 1 system 2 systems

PA 605 1 x ∅70 mm 1 x ∅100 mm

38 577217-02

Page 39: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 4 SPECIFICATIONS

A

G0

04

40

3A

G0

04

31

6A

4.6 Sludge Piping

Specification

• The sludge pipe from the separator to the sludge tank should be vertical.

If a vertical pipe is not possible, the deviation (A) from the vertical line must not exceed 30°.

• The sludge pipe must not extend below the tank top.

NOTE

An extended sludge pipe will obstruct ventilation and create back pressure that could cause separator problems.

577217-02 39

Page 40: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

4 SPECIFICATIONS PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

G0

04

41

2A

If more than one separator is connected to the same sludge tank, a butterfly valve should be installed in each sludge pipe.

NOTE

If a butterfly valve is not used, the bowl and the operating system may be affected.

• If a butterfly valve is used, it should be equipped with an interlocking switch (connected to the separator starter) to prevent the separator from being started when the valve is not fully open.

40 577217-02

Page 41: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 5 COMMISSIONING AND INITIAL START

5 Commissioning and Initial Start

5.1 Completion Check ListIt is essential before starting up the separation system that all units are in good operating condition and that all pipelines and control equipment are properly connected to assure correct operation.

Use this check list as a guide for completing the system installation:

WARNING!

Breakdown hazardCheck that the power frequency is in agreement with the machine plate. If incorrect, resulting overspeed may cause breakdown.

1 Check that transport seals are removed from all pipes.

2 Use flushing filters to prevent pipe work debris from being pumped into the separation system.

NOTE

The flushing filters must be removed after initial flushing.

3 Check that all separators are in proper working condition. Follow the manufacturer’s instructions.

4 Make sure that separators are lubricated in accordance with instructions.

NOTE

Make sure that the spindle bearings are prelubricated

5 Separators are delivered without oil in the oil sump. For information on oil filling and oil type, see the Service Manual booklet.

577217-02 41

Page 42: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

5 COMMISSIONING AND INITIAL START PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

NOTE

Too much, or too little oil may result in damage to separator bearings.Neglecting an oil change may result in damage to separator bearings.

6 Power on.

7 Check that the separator rotation direction corresponds with the arrow on the frame by doing a quick start/stop (1–2 seconds.) and looking at the motor fan rotation.

CAUTION!

If power cables have been installed incorrectly, the separator will rotate in reverse, and vital rotating parts can unscrew.

8 Check the pump function and direction.

42 577217-02

Page 43: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 5 COMMISSIONING AND INITIAL START

5.2 Initial Start-up

Use this check list for initial system start up:

1 Check that there is oil in the feed oil tank.

2 Check water and air supply. See ‘‘System Data” on page 6.

3 Check power supplies to the control unit and that the voltage is in accordance with data in ‘‘System Data” on page 6.

4 Check all parameter settings in the control unit. See Installation Parameters in the Parameter List booklet.

NOTE

The Control Unit is supplied with standard configuration parameters. You may have to make some changes to suit your installation.

5 Start the separation system as described in the Operating Instructions booklet.

6 Start up step by step, checking that the machine and units function properly.

7 Establish system pressures.

The delivery height pressure is the pressure in the oil pipe work down stream from the separation system, due to the pipe bends and the height (head) to the cleaned oil tank. If the cleaned oil tank is below the separation system the delivery height pressure may be very low. The oil paring disc pressure will have to be greater than the delivery height pressure for any oil to flow. Proceed as follows:

• Ensure the valves in the oil system are in the correct positions.

• The oil should be at separation temperature.Cont.

577217-02 43

Page 44: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

5 COMMISSIONING AND INITIAL START PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

• Ensure that V5 is closed.• Fully open the back pressure regulating valve

RV4.• The shut off valve V4 should be open.• Open SV15 for 3 seconds to prime the

operating slide.• Open SV16 for 15 seconds to close the bowl.• Open SV10 for 30 seconds to put water into

the bowl.• Feed oil to the separator at the normal flow

rate by opening SV1.• Note the pressure in the oil outlet PT4, both on

the pressure gauge and in the EPC50 display. This pressure is P min.

• Gradually close the back pressure regulating valve RV4. The pressure on PT4 will increase. The water pressure (PT5) decreases slightly as the paring tube moves inwards. The water pressure will suddenly drop when oil passes from the oil paring chamber to the water paring chamber. Note the pressure of PT4 both on the pressure gauge and in the EPC50 display. This pressure is P max.

• Open RV4.• Stop the oil feed to the separator and note the

pressure in the oil outlet. This is the delivery height pressure P del.

• Stop the heater.• Stop the separator.• Stop the feed pump when the heater has

cooled.

44 577217-02

Page 45: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 5 COMMISSIONING AND INITIAL START

5.2.1 Calculating Operating Pressure

• Calculate the normal back pressure level during operation as follows:

• Calculate the value for low pressure alarm setting (Pr 11) as follows:

• Calculate the value for high pressure alarm setting (Pr 10) as follows:

Adjust the back pressure to Pnormal

Set Pr 11 to give alarm at pressure decreasing below the Plow press. value.

Set Pr 10 to give alarm at pressure increasing above the Phigh press. value.

Pmin + Pmax = Pnormal

2

Pmin + Pnormal = Plow press.

2

Pnormal + Pmax= Phigh press.

2

577217-02 45

Page 46: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

5 COMMISSIONING AND INITIAL START PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

46 577217-02

Page 47: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 6 SHUT-DOWN AND STORAGE

6 Shut-down and Storage

> 6 months See

x This chapter

x This chapter

x Service manual

x Service manual

> 12 months

See

x Dismantling and Assembly in the Service Manual

x This chapter

x This chapter

x Service manual

x Service manual

Storage before Installation

If the separation system is stored before installation, the following safeguards must be taken:

6.1 Shut-down after UseIf the separation system is going to be shut down for a period of time, the following safeguards must be taken:

Storage period < 6 months

Action

Protect from dust, dirt, water, etc.

x

Protect with anti-rust oil

x

Inspection x

Overhaul

Shut-down period

< 3 months

(stand-by)

3 – 12 months

Action

Remove bowl x x

Protect from dust, dirt, water, etc.

x x

Protect with anti-rust oil

x x

Inspection x

Overhaul

577217-02 47

Page 48: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

6 SHUT-DOWN AND STORAGE PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

6.2 Protection and Storage

All system equipment, both the separator and the ancillary equipment, must be stored indoors at 5 – 55°C, if not delivered in water-resistant box for outdoor storage.

If there is a risk for condensation of water, the equipment must be protected by ventilation and heating above dew point.

The following protection products are recommended:

• Anti-rust oil with long lasting effective treatment for external surfaces. The oil should prevent corrosion attacks and give a waxy surface.

• Anti-rust oil (Dinitrol 40 or equivalent) thin and lubricating for inside protection. It gives a lubricating transparent oil film.

• Solvent, e.g. white spirit, to remove the anti-rust oil after the shut-down.

• If the storage time exceeds 12 months, the equipment must be inspected every 6 months and, if necessary, the protection be renewed.

Rubber Parts

• Gaskets, O-rings and other rubber parts should not be stored for more than two years. After this time, they should be replaced.

Separator

Dismantle the separator bowl and take out the O-rings. Clean the bowl with oil and reassemble without the O-rings. Place in a plastic bag with silica dessicant bags and seal the plastic bag.

Grease the spindle.

48 577217-02

Page 49: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 6 SHUT-DOWN AND STORAGE

Valves, Pipes and Similar Equipment

• Components like valves need to be cleaned with solvent and treated with anti-rust oil (type 112).

• Water pipes should be drained and treated with anti-rust oil (type 112).

• Articles made of rubber or plastics (e.g. seals) must not be treated with anti-rust oil.

6.3 Reassembly and Start up

• Clean away the anti-rust oil with white spirit.

• Remove the silica gel bags from all units.

• Follow all relevant instructions in the Service Manual and Operating Instructions.

577217-02 49

Page 50: Installation System Reference - cappato.net Laval/PDF/Depuratori/PA605/Manuale... · 2.2.8 Control Unit EPC 50 Dimension ... PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE 1

6 SHUT-DOWN AND STORAGE PA 605 PURIFIER SYSTEM INSTALLATION SYSTEM REFERENCE

50 577217-02