2
FEATURES Made in USA 48V working voltage Individually balanced cells IP-67 rating Optional factory installed heat sink Fits in industry standard footprint APPLICATIONS High power High rate cycling High cycle life (>1,000,000 cycles) MARKETS Transportation Subsystem Engine starting Regen energy capture Backup power Grid/power correction UPS/ride through power MARKINGS Products are marked with the following: Rated capacitance, rated voltage, product number, name of manufacturer, positive and negative terminal marking, maximum energy content. www.ioxus.com | [email protected] iMOD™ 48V 165F Module 418 156.26 350 230 25 25 179.03 HEAT SINK HEAT SINK 193.85 200 4x 9 2X 170 2X 396.20 56.13 M8 POSITIVE TERMINAL M10 NEGATIVE TERMINAL I/O CONNECTOR 95.33 MOUNTING RECOMMENDATION Do not reverse polarize. Install following recommendations in Notes on Using Ultracapacitors, available at www.ioxus.com. Contact your Ioxus representative for ordering and application information regarding sizing and to purchase integration kits Corporate Headquarters North American Sales 18 Stadium Circle Oneonta, NY 13820, USA Toll Free: +1-877-751-4222 [email protected] TEL: 607-441-3500 FAX: 607-433-9014 Ioxus (Shanghai) Clean Energy Technology Co. 翱旭(上海)清洁能源技术有限公司 2616 Ascendas Plaza, 133 Tianyaoqiao Rd Xuhui District, Shanghai 200030, China 电子邮件: [email protected] 电话 : +86 13564250125 Ioxus Japan Co. LTD 1381-1 Okamotocho Kusatsu-city, Shiga Pref 525-0044, Japan [email protected] TEL : +81-77-569-5106 FAX: +81-77-569-5168 RETHINK POWER ©2015 Ioxus, Inc 150108

iMOD™ 48V 165F Module - Ioxus · TEL: 607-441-3500 FAX: 607-433-9014 Ioxus (Shanghai) Clean Energy Technology Co. 翱旭(上海)清洁能源技术有限公司 2616 Ascendas

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

FEATURESMade in USA48V working voltageIndividually balanced cellsIP-67 ratingOptional factory installed heat sinkFits in industry standard footprint

APPLICATIONSHigh power

High rate cyclingHigh cycle life (>1,000,000 cycles)

MARKETSTransportation Subsystem

Engine startingRegen energy capture

Backup powerGrid/power correction

UPS/ride through power

MARKINGSProducts are marked with the following: Rated capacitance, rated voltage, product number, name of manufacturer, positive and negative terminal marking, maximum energy content.

www.ioxus.com | [email protected]

iMOD™ 48V 165F Module

418

156.26

350

230

25

25

179.03

HEAT SINK

HEAT SINK

193.85 200

4x 9

2X 170

2X 396.20 56.13 M8 POSITIVE TERMINAL

M10 NEGATIVE TERMINAL

I/O CONNECTOR

95.33

MOUNTING RECOMMENDATIONDo not reverse polarize. Install following recommendations in Notes on Using Ultracapacitors, available at www.ioxus.com. Contact your Ioxus representative for ordering and application information regarding sizing and to purchase integration kits

Corporate HeadquartersNorth American Sales

18 Stadium Circle Oneonta, NY 13820, USA

Toll Free: [email protected]

TEL: 607-441-3500FAX: 607-433-9014

Ioxus (Shanghai) Clean Energy Technology Co.翱旭(上海)清洁能源技术有限公司

2616 Ascendas Plaza, 133 Tianyaoqiao RdXuhui District, Shanghai 200030, China电子邮件: [email protected]电话 : +86 13564250125

Ioxus Japan Co. LTD

1381-1 OkamotochoKusatsu-city, Shiga Pref

525-0044, [email protected]

TEL : +81-77-569-5106FAX: +81-77-569-5168

RETHINK POWER

©2015 Ioxus, Inc 150108

www.ioxus.com | [email protected]

PRODUCT SPECIFICATIONS

©2015 Ioxus, Inc

ADDITIONAL TECHNICAL INFORMATIONProduct specification test and calculation methods are available in Ioxus Notes on Datasheet Specifications

150108

ELECTRICAL\PART NUMBER iMOD048V165A22-01B iMOD048V165A22-31BCapacitance (F) [Min/Nom] 165/180

Voltage (Rated/Surge) [VR/VS] 48.6/51.3

DC ESR 10ms (mΩ) [Nom/Max] 3.5/5.0

IEC DC ESR (mΩ) [Nom/Max] 4.5/6.0

AC ESR(mΩ 1kHz) [Nom/Max] 3.3/4.0

Hi Pot Test Voltage 3500VDC

UL Max Operational Voltage (per UL810A) 750V (per series string)

CYCLING (Calculated from nominal values)

Current, Peak [1s] (A) 2600

Continuous Current (A) [20°Rise] 112 TBD >120

Current, Short Circuit (A) 13800

THERMAL (Reference)

Operational / Storage Range (°C) -40 to 65 °C / -40 to 70 °C

Resistance, Thermal (°C/W) [RTH] 0.317 TBD <0.300

ENERGY (Reference / Calculated using nominal values)

EMAX (Whr) [Min/Nom] 54.1/59.0

PHYSICAL (Nominal Values)

L (mm) 418

W (mm) 194 200

H (mm) 179 207

Mass (kg) 14.5 15.5

Volume (L) 14.5 17.3

Terminal Fastener Size / Max Torque M8/20Nm & M10/30Nm

LIFE (EOL Criteria) [Capacitance/IEC DC ESR] *Life is a provisional value

DC (10 Yr, 25°C, @VR) [F/mΩ] >132/<12

Endurance (1000hr, 65°C, @VR) [F/mΩ] >132/<12

Storage (4 yr, 25°C, @ 0V) [F/mΩ] >148/<9.0

Cycle (1M Cyc, 25°C, @ VR-VR/2) [F/mΩ] >132/<12

STANDARDS COMPLIANCE (Those in italics are pending)

Safety/Environmental RoHS, UL810a, Chinese RoHS, IEC 60068-2-14

Shock IEC 60068-2-27 ,SAE J2464 (T4), ISO 16750-3 (sec 4.2.2)

Vibration IEC 60068-2-6, SAE J2380 (T1), ISO 16750-3 (Tables 12 & 14)

MONITORING CONNECTOR (please see manual for additional details)Module Connector Conxall 7280-4PG-300

Recommended Mating Connector Conxall 6280-4SG-522

Thermistor Sensor (NTC) Cantherm MF52A1103G3380

Pin Out 1- Digital Over-Voltage (+), 2- Digital Over-Voltage (-), 3&4 Thermistor