    INSTALLATION GUIDE

    Specifications RKL40 RPKL40 RKLB40

    BASE PART NUMBER 929N 929P 928N

    INPUT VOLTAGE (VDC) 12VDC 12VDC 12VDC

    CURRENT

    STANDBY AVG1 170mA 170mA 195mA

    MAX AVG2 185mA 185mA 255mA

    PEAK3 250mA 250mA 320mA

    OPERATING TEMPERATURE

    -4°F to 149°F (-20°C to 65°C)

    -4°F to 149°F (-20°C to 65°C)

    14°F to 122°F (-10°C to 50°C)

    CABLE LENGTH Communication Lines Wiegand

    500ft - 22 AWG (152m) 300ft - 24 AWG (91m)

    RS-485 Max Bus Length: 4000ft (1,219m) - 24 AWG

    Max Lenth Between Nodes: 1640ft (500m) - 24 AWG

    UL REF NUMBER4 RKL40Ex1x2x3 RPKL40Ex1x2x3 RKLB40Ex1x2x3 SRD MODEL RKCL40E RPKCL40E RKCLB40E

    1 Standby AVG - RMS current draw without a card in the RF field. ² Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL. 3 Peak - highest instantaneous current draw during RF communication. 4 UL Reference Number Deciphering

    x1 Reader Colors K = Black, G = Gray

    x2 Wiring N = Pigtail, T = Terminal

    x3 Communications N = No Module, R = RS-485

    Parts Reader and base plate assembly (1) Installation Guide (1) iCLASS SE Biometric Reader User Guide (RKCLB40 only) (1) Terminal connector (2) M3.5 mm x 12 mm Phillips machine screw (4) #6-32 x .375" Phillips self-tapping machine screw (4) #6 x 1.5" Phillips sheet metal screw (4) #6-32 x .4375" Spanner security screw, anti-tamper (black) (3) #6-32 x .4375" Phillips security screw (black) (3) Mounting Gasket (1) SE BIO Initial Setup Reset Card 1 (RKLB40 only) SE BIO Initial Setup Reset Card 2 (RKLB40 only)

    Recommended Cable, 4 conductor, 22 or 24 AWG (65 mm or 51 mm) twisted pair, over-all shield and UL approved (Belden 3107A, or equivalent) - RS–485 + power Cable, 6 to 9 conductor, 22 or 24 AWG (65 mm or 51 mm) over-all shield, (Alpha 1296C or equivalent) - Wiegand + power DC power supply Metal or plastic double-gang junction box Reader spacer when mounting on or near metal or metal junction boxes - see How to Order Guide Security tool (for spanner security screw, anti- tamper) HID 04-0001-03

    iCLASS SE® Biometric/ iCLASS SE Display Reader RKL40, RPKL40, RKLB40 SRD MODEL: RKCL40E, RPKCL40E, RKCLB40E

    This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.

    © 2017 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID Brick Logo, the Chain Design, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.

  • RKL40, RPKL40, RKLB40 SRD MODEL: RKCL40E, RPKCL40E, RKCLB40E

    iCLASS SE® Biometric/ iCLASS SE Display Reader PLT-03331, Rev. A.2

    2

    PIGTAIL TERMINAL DESCRIPTION Yellow P1-1 Beeper Input

    Orange P1-2 LED Input (GRN)

    Black P1-3 Ground (RTN)

    Red P1-4 +VDC

    Drain P1-5 Unused

    Brown P1-6 LED Input (RED)

    Blue P1-7 Hold Input

    Red/Green P2-7 GPIO1/OSDP (RS485-FDX/HDX-A)

    Tan P2-6 GPIO2/OSDP (RS485-FDX/HDX-B)

    Violet P2-5 *Open Collector Output / Tamper

    White P2-4 **Wiegand Data 1 / Clock

    Green P2-3 **Wiegand Data 0 / Data

    Pink P2-2 GPIO3 (RS485-FDX-Z)

    Gray P2-1 GPIO4 (RS485-FDX-Y)

    Wall backplate

    Install gasket

    Junction box not included

    ATTENTION Observe precautions for handling ELECTROSTATIC SENSITIVE DEVICES

    P1

    P2

    Beeper GRN LED

    GND +VDC

    DRAIN RED

    HOLD

    GPIO1 GP102 OC/TMPR DATA1/CLK DATA2/DATA GPIO3 GPIO4

    Beeper GRN LED

    GND +VDC

    DRAIN RED

    HOLD

    GPIO1 GP102 OC/TMPR DATA1/CLK DATA2/DATA GPIO3 GPIO4

    1 Mounting

    2 Wiring

    Mounting holes for US double-gang electrical boxes.

    Terminal Reader (Terminal block and

    module position varies)

    Notes Previous iCLASS readers had reversed RS-485 wiring (P2-7 & P2-6 - A & B). When upgrading to an iCLASS SE reader, ensure proper connections as defined below. It is possible to reuse existing Wiegand wiring for OSDP, however, using simple stranded cable typical of Wiegand access control readers is usually not meeting the RS485 twisted pair recommendations. For OSDP cable lengths greater than 200ft. (61M) or EMF interference, install 120Ω +/- 2Ω resistor across RS-485 termination ends. Wiring the reader incorrectly may permanently damage the reader.

    Reverse Configuration Rotating the backplate 180° allows for placing the LCD display on left and the reader on right. See PLT-02969 - Alternate Reader Assembly for instructions, before proceeding to Step 2: Wiring. Scan the QR Code or visit www.hidglobal.com/PLT-02969

  • RKL40, RPKL40, RKLB40 SRD MODEL: RKCL40E, RPKCL40E, RKCLB40E

    iCLASS SE® Biometric/ iCLASS SE Display Reader PLT-03331, Rev. A.2

    3

    3 Attach to Backplate

    Mount the Reader Assembly (Reader, LCD Assembly, and reader backplate)

    to the wall backplate.

    Standard Configuration: Slide Reader Assembly towards the right to lock.

    Alternate Configuration: Slide Reader Assembly to the left to lock.

    Install Security screws.

    4 Power and Testing

    Notes With a keypad reader, operating as 26 bit emulation; upon power up you have five seconds to enter the Facility Code followed by #. If unsuccessful, the reader LED displays solid Red. Power-cycle the reader and retry entering the Facility Code. The Facility Code needs to be manually entered as three digits (i.e. a Facility Code of 10 is entered as 0-1-0-#). SE readers only use Facility Codes between 1-255, and there is no default Facility Code. Once the Facility Code has been entered, the LED will display Violet and then to Red. Power-cycle the reader to complete the Facility Code configuration. When using a keypad, if two short beeps are heard after entering your PIN, the reader does not have a Facility Code configured yet. In this event, an Admin will need to power-cycle the reader and enter the Facility Code before the reader will accept a PIN.

  • hidglobal.com

    PLT-03331, Rev. A.2

    GUIDE D'INSTALLATION

    Caractéristiques RKL40 RPKL40 RKLB40

    RÉFÉRENCE DE BASE 929N 929P 928N

    TENSION D'ENTRÉE (Vcc) 12 Vcc 12 Vcc 12 Vcc

    COURANT

    MOY VEILLE1 170 mA 170 mA 195 mA

    MOY MAX.2 185 mA 185 mA 255 mA

    CRÊTE3 250 mA 250 mA 320 mA

    TEMPÉRATURE DE FONCTIONNEMENT

    -4 °F à 149 °F (-20 °C à 65 °C)

    -4 °F à 149 °F (-20 °C à 65 °C)

    14 °F à 122 °F (-10 °C à 50 °C)

    LONGUEUR DE CÂBLE Lignes de communication Wiegand

    500' - 22 AWG (152 m) 300' - 24 AWG (91 m)

    RS-485 Long. max du bus : 4000' (1219 m) - 24 AWG

    Distance max. entre nœuds : 1640' (500 m) - 24 AWG

    NUMÉRO DE RÉF. UL4 RKL40Ex1x2x3 RPKL40Ex1x2x3 RKLB40Ex1x2x3 MODÈLE SRD RKCL40E RPKCL40E RKCLB40E

    1 MOY veille : courant efficace sans carte dans le champ RF. ² MOY max. : courant efficace durant les lectures de carte continues. Non évalué UL. 3 Crête : courant instantané le plus élevé durant une communication RF. 4 Décryptage du numéro de référence UL

    x1 Couleurs du lecteur :

    K = Noir, G = Gris

    x2 Câblage N = Pigtail, T = Borne

    x3 Communications N = aucun module, R = RS-485

    Pièces Ensemble lecteur et socle (1) Guide d'installation (1) Guide de l'utilisateur du lecteur biométrique iCLASS SE (RKCLB40 uniquement) (1) Connecteur de borne (2) Vis à métaux Phillips M3,5 mm x 12 mm (4) Vis autotaraudeuse Phillips n° 6-32 x 0,375” (4) Vis à tôle Phillips n° 6 x 1,5” (4) Vis de fixation à entretoise n° 6-32 x 0,4375”, inviolable (noire) (3) Vis de fixation Phillips n° 6-32 x 0,4375” (noire) (3) Support d'assemblage (1) Carte de réinitialisation 1 pour la configuration initiale du SE BIO (RKLB40 uniquement) Carte de réinitialisation 2 pour la configuration initiale du SE BIO (RKLB40 uniquement)

    Pièces recommandées Câble 4 conducteurs 22 ou 24 AWG [65 mm ou 51 mm] à paires torsadées, entièrement blindé et homologué UL (Belden 3107A ou équivalent) - RS-485 + alimentation Câble 6 à 9 conducteurs 22 ou 24 AWG [65 mm ou 51 mm] entièrement blindé (Alpha 1296C ou équivalent) - Wiegand + alimentation Alimentation cc Boîtier de raccordement à double commande en métal ou plastique Pièce d'espacement pour le montage sur ou à proximité de métal ou de boîtiers de raccordement en métal - voir le Guide des commandes Outil de sécurité (pour vis de fixation à entretoise inviolable) HID 04-0001-03

    Lecteur biométrique iCLASS SE®/Lecteur iCLASS SE RKL40, RPKL40, RKLB40 MODÈLE SRD : RKCL40E, RPKCL40E, RKCLB40E

  • RKL40, RPKL40, RKLB40 SRD MODEL: RKCL40E, RPKCL40E, RKCLB40E

    iCLASS SE® Biometric/ iCLASS SE Display Reader PLT-03331, Rev. A.2

    5

    PIGTAIL BORNE DESCRIPTION Jaune P1-1 Entrée bip

    Orange P1-2 Entrée LED (VERT)

    Noir P1-3 Masse (RTN)

    Rouge P1-4 +V cc

    Drain P1-5 Non utilisé

    Marron P1-6 Entr