Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
FORM 1: IDENTIFICATION OF THE APPLICANTExplanations of the datasheets are provided in the NCCD System Guidelines. Allapplicants shall fill 'Form l' for each project submitted for appraisal. Apart from this,relevant datasheet for individual components to be filled by beneficiary seeking subsidy.
A: Identification ofthe Applicant
Narne of Promoter (s)
Name of Commercial Entity/Enterprise
Type of Commercial Entity(Proprietorship jPartnership jPvt. Ltd / Ltd / PSU/ StateUndertaking)Postal address of Entity
Tel/Fax Mob. No E-mail
Present activity in brief
Name of Contact Person Phone:
Mobile No:
Email:
B: Project Milestone
Date for aoolication for subsidyDate of Project StartAmount of Bank Loan SanctionDate of Bank Loan Sanction
.
Last Annroval/lnsoection StatusName of Aooroving BodvPAN Number registered withbank.If Project Commissioned Date of comnletion certificate I Issuinl' Authority
I
C: Project Identification: Pre-Cooler/Cold storage / Pack-House / Reefer Vehicles / RetailShopsName of ProjectType of Project (please tick) New Project Expansion Modernisation
.
Location of Project Address Village/Town(complete address) District StateManpower Employed(on rolls/on cop tract)What Business model is used
i(rental, captiv~, part of supplychain service, ~ixed)Years in businessComponents of Project submitted Integrated pack house(please tick) Pre-cooling unit
Cold Room (Staging)Check list for individual Cold Storage Unit Type 1Data sheets submitted Cold Storage Unit Type 2
CAGeneratorSpecialised CADoorCATentProgrammed Logic Control SystemsDock Leveller System .
, WDRA-NWR Equipmenti Specialised Packagingi, High Reach MHE
Modernisation of RefrigerationModernisation of InsulationReefer Container Units .
Advanced Grader systemStacking System
i Retail Shelf / CabinetAlternate Energy OptionRefrigerated Transport VehicleRipening FacilityOthers (please name)
Type of Products to be handled Temperature Zones(Frozen, Chill, Mild-chill) < -l8°C 0-1O°C lO-20°C
Fill up relevant data sheet for each project component.
MIDH OPERATIONAL GUIDELINES- ANNEXURE-V (C6) & ANNEXURE-VII (Bl, B2)
COLD STORAGE UNITS
Data Sheet for Cold Storage Type 1: (refer sample sheet)
i) ColdStore Chamber Sizing and CapacityPlease enclose Sketch with Plan layout and sections showing the storage chamber
~~~ tIiambefcl?i~ ~~~~~~r~~~ ch:imber:3':;tr Chamller4 :<i~i?ChamblifSJ'J¥'(, ""?(,, x> "';"-'I; _"iC, ~( ,:_,_, _~';~-,,_ BL ;".' "'W: - ',:,i ;.~~',,' ,M;:._ // '''''---''', ,;,-
Temp. Zone & RelativeHumidity conditionsName of Produce
.
Number of platform perI
chamber IIII
Type of platform used
Dimensions of CS chambers ineach group (Lx W x H) m
Storage Capacity of eachchamber in tons
Storage unit used (Bags,crates, carton, bulk heap, etc.)
Total number of storage unit
Weight per storage unit
Heat load per chamber (kW)•
Any other information
.
I
ii
Describe Handling, receiving area(covered, open shed)
Describe Loading / Unloadingplatform
iin Facilitv covered AreasCold Storage Area and height
Machine room areal height
.
Generator room area / height,
Admin Block area / height
ivl Buildinl! & Construction DetailsType of building construction
External walls/Internal walls/Partition walls of cold chambers
Specification ofRoof/Ceiling
I!,
Lighting fixtur~s in cold chambers
,!
Specification in process/External/compound areas
Others
vl Insulation and Vapour Barrier,'I't,;:"';" :;::;:T:;:, '. f,,; " ',,:;. WaIr' ,Type ofInsuliltlon11'.; • ':; E' I 'f.,. ,. :; .L,,", ;..••..' :; '",1,1:; xterna' 'I, Internal".Specification of insulation material
Specification of composite panels
Relevant IS Code
Thermal Conductivity (k-value) at+10°C (mean temperature) in W/m.K
!U-value {W/(m2~))
IThermal diffusi~ity (m2/ sec)
!
Vapour barrier specification
Total Insulation thickness and number
oflayers
Specification on! Cladding
I
I,Locking/Fixing & Sealing System incase of Metal Skin composite Panels,
i
Type hinged / sliding/ Rolling
Details
J
Size of door opening (W x H). I
Insulation Material-Type and Uvalue {W/(m2K)}
Thickness of Insulation (mm)
Type of skin :,,
:i!
Provision of' Strip curtains/Aircurtains -nos and dimensions(WxH)m.
Internal Emergency Door release
vii) Heat Load Estimation InputsProduct wise Storage condition:
Storage temperature in °C:
!Relative humidity in %:
Air circulation:rate in CMH:Loading Period (days/weeks)
:.i:
Maximum storage period(weeks/months)
Product loading temperature (OC)
Loading rate per day (MT/day) .
Pull down rate (hours)
Estimated Daily unloading rate
from each cold:chaml:>er (MT/day)
Ante Room cum staging areaconditions (DC)
CO, Concentration Control (PPM)
,
Number' of Fresh air changes per
day
Brief Description of Fresh AirVentilation system
I;
!Explain heat 'recovery system, if I 'used
VIII Heat Load Calculation of Coolin S stem - SummaAmbient Conditions
D
Building dimensions:
Total Capacity of the storage:
Number of the chambersNote: Please attach additional heat load estimation for, as applicable depending upon, different group ofcommodity planned.
ratioti'l..dad j";@J!X;;,*;~. ;.~:~,DurinTransmission Load (kW)
I
Product Load (]kW)Ii
Internal Lighting load
Load (kW)
Occupancy load
Infiltration Load (kW)
Ventilationf Fresh Air (kW)Refurbishment Load
I
i
j
Equipment Load - Evap. Fanmotors, MHEetc. (kW)
Pull Down Period
Holding period
Defrosting Period
Cooling System Design Detail
ix) Coolin" System Confi"uration: Mechanical Refril'erationType of Refrigerant
Total refrigeration system capacity(kW)
Type of System
Type of compressor
Type of capacity control
SpecifY Unloading steps inpercentage
Type of condenser
Cooling Towers (if applicable)
Type of Evaporatorsf Air cooler
Type of defrosting
Humidification System &Control
. t
Refrigeration Equipment Detailsxl CoinDressor I Rack Detail
Compressorf Operating... .. -
Total... .. . ...
Refrigeration PowerRacks Qty. Compo Parameters Capacity Consumption connected Remarks WorkingType, RPM SST. f Condo Motor fStandby
Make &Model! Terrio f0el (kW) .(kW)rkW)
Full load:
Part load:
xil Condenser DetailsCondenser IQty. Operating Condenser Electric Fan Total Remarks Working
Type, Make &: Parameters Heat Rejection fPump Motor Electric . fStandbyModel Condensing' Capacity Rating ".Power,
Temp.(CT) (kW) . (kW) (kW)WBT, waterinJout
temofoCl..., ..
Fan&Pump TotalElectricPower"
Remarks WorkingfStandby .
xiiil Pressure VesselsDescription Type
.. _.Refrigerant Operating
..Construction . Total Holding Volume ,I
Horizontal Temp & Shell, Dish Ends Refrigeration ~ " ".'.
Vertical .. Pressure & Nozzles loadLowPressure
I
HighPressure
Note: The design and testing of the pressure vessel should comply with ASMESec VIII Div 1.
'TD - Temperature difference between Evap. (SST) DC & Return Air (at coil inlet).
Note: Please attach D.etailed Technical Performance Data Sheets of each equipment namelyCompressors; Condensers, Cooling Towers, Air Cooling Units giving General Layout andDimensions duly Certified by the respective equipment manufacturers with reference to theRelevant Codrs & Standards.
xv) ElectricalInstallation:Total Connect~d load (kW)
iI
Estimated power requirement atPeak Load Period (kW)Estimated power requirement atHolding Load Period (kW)
Estimated power requirement atLean Load Period (kW)
•Capacity ofTr~nsformer (kVA),
Size of Capacitor
Make & Capacity of standby D.G.Sets(nos and kVA)
xvi
Material Handling Procedures& Equipment
Capacityconveyormotor
of mechanised belt(k:-V) if any-Rating of
Any other device please specify,Attach a Plan & Layout of the proposed Cold Store unit approved by a Registered Architect.
JI
xvii) Safety Provisions:Include Machine room ventilation s stem for se1f-containin
Fire Fighting equipment installed asper Fire safety standards of StateFire Department
Handling measures for Refrigerants& Leaks installed.
Safety devices - LP/H P cut outs,safety valves, shut off valves etc.installed
Emergency lighting in Coldchambers & other areas installed
Lightening arrestors installed
Any other safety provisionsdescribe
Natural Lighting for general areas
VFD / Electronic Technology for fans/ compressors
.. ,BriefDescri .tioll lInd saVih S~f
RefrigerantAutomation
Air Purger
Controls and
Power Factor Controller
Energy recovery
Any other Components
Coefficient OfPerformance (COP)of the ColdStqre Unit
Ii
Power Consumption (kWh/Day)
,;;('Brief DescJ'J tionallllSavin'
Prevailing(Rs/kWh)
Electricity . costs
xx) Brief description of any other technologies or infrastructure usedReefer trucks operated (if any)
Specialised packaging lines (if any)
PLCAutomation (ifany)!
DockLevellers systems (if any)
Alternate energy options (if any)
Modern Pack-house (if any). .
OthersI
Project declares compliance with all mandatory codes and regulations are complied with
Append details in separate data sheets for 'add-on components' if also applying for thesecomponents.
Total number of Chambers
ii) Chamber Sizing and InformationPlease bnclose Sketch with Plan layout and sections showing the storage chamber
,k5"'i,;'~""'!" '"g", Chambers Chambers Chambers Cllambers :'. Chambers;m;\:~ ,1"~,y 1'~,~::C,!,,"'1~"'--,;~:'Deta~,ls' ' ;k, Group l' , GrOlip2, , ' Groun3, , " Group'ii j,"--~ )1'. 0 Y. "" ii Grouu4,
Storage ConditiqnTemo, & RelativeHumiditvProduct,types
Number of chambers pergroup
Dimensions of chambers ineach group (LxWx H)m
Storage Capacity of Eachchamber group (cubicmetres)
Storage units (Pallets, bulkbins, cartons, etc,)
Stacking system lused,i
Total Heat Load calculatedper chamber group (kW)
Total Refrigeration capacityper chamber group (kW)
iii Enclosed Ante Room & Handlin Area::j*'";~t-~~tf~_~i~'k2t>_et~-i1s _,-~-:;--M-1~'Jiiforlti~ti:O'n_;t\---;{/~Ante room/Handling Area(LxWxH)m
Refrigeration Load (kW)
Number of Access Doors
Dock Leveller system
ivl Facilitv Covered AreasCold Storage ~rea and height
IAnte room area
Receiving room area and height
Machine room area and height
Generator room area,,,I,
Admin Block ~rea and height
v) B\Iildin2 & Construction DetailsType of building construction(load bearing construction)
;
External walls/Internalwalls/Partition walls of coldchambers
I
1
Roof/Ceiling ~onstruction
IIIII
--l,
Lighting fixtures in cold chambers
Externaljcompound areas
Others,I,
vi Insulation and Va our Barrier,;'~e',(){jfi~:ul~Uon~4y~t~;f~_;ll1C\:;_,,J;lti~¥J:
Specification of insulation material,,
Specification 0 composite panels
Relevant ISCode
Thermal Conductivity (k-value) at+ 10°C (mean temperature) inW/m.K
U-value{W /(m'K)}
Thermal diffusivity (m'/sec)
Vapour barrier specification
Specification on Cladding
Locking/Fixing & Sealing System incase of Metal Skin composite Panels
vii) Stora2e Chamber insulation & details:, Chamber Ceiling
-External wall Internal wall Floor Internal
number thiCkness (mm) thicloiess(mm) thickness(mm) insulation Dimensionsthicknessfmml fLxBxH)m
1 .
2
3
4
5
6
7
8
9 I
i10 I11 I
I,12
Total volume of all chambers (cubic metres)
Total Transmission load of chambers (kW)
viii) Cold Store Doors & Air IStrip barrier or curtainChamber Nu~berof .. .Door Ope'1ing Thickness(mm) . Strip curtain Opens tonumber q.oors (wxh) m , .& 'U-value' or air curtairi (ante-room
I oroulsidel1 ,,
2
3
4
5
6
7
8t
Chamber Number <if .Door Opening Thickness(liIm) Strip curtain Opens to .. number l>oors . (wxh)m' -& 'U-valUe' or air curtain (ante-room ...
or outsidel,
. '.'-
9
10
11
12
ixl Heat Load Estimation InDutsProduct Storage condition
Storage temperature in 0C:,I
Relative humi~ity required in %:I,
Air circulation'rate in CMH:Daily Door Opening
Estimated mass of products to beloaded and unloaded daily (MT)
Ante Room area conditions (0C)
Special Provisions (describe)
xl Fresh Air I Ventilation SvstemNumber of Fresh air chanpesBrief Description of Fresh AirVentilation system
CO, Concentration Control RangePPM)Monitoring & Control Instrument,
II
iI
Explain heat recovery system,if used.
xi Heat Load Calculation of Coolin S stem - SummaAmbient Conditions
Dry Bulb temperature (Summer)
Building external dimensions: mtrs
Total Capacity of the storage: cubic mtrs
Number of the chambers: nos
Note: Please attach additional heat load estimation for, as applicable depending upon, different group ofcommodity planned.
..... . Refril!eration Peak Load in kW(for storal!e chambers) .Transmission Load (kW)
Product Load (kW)
Lighting load•I
Occupancy load.. I
Infiltration Load (kW)
Internali Load(kW)
Ventilation/ Fresh Air (kW)Refurbishment Load
Equipment Load - Evap. Fanmotors, MHEetc. [kW1Total Load of Ante.room
Pull Down Period
Compressor Holding period
OperationHourS/Day
Defrosting Period
....
I Multipliers (Safe! Factor) 1,--' _
[ .. Peak Period(kW) . Holding Period(kW) ..Total Refriget:ation Load
Cooling System Design Detail
system capacity
Type of compressors
Type of capacity controls used
SpecifY Unloading steps in percentage
Type of condensers
Cooling Towers (if applicable)
Type of Evaporatorsf Air cooler
Type of defrosting system
Humidification~ System &Control!I
Refrigeration Equipment Detailsxiiil ComDressor I Rack Detail
Compressorf! Operating Refrigeration. Power TotalRacks Qty. Compo Parameters Capacity .. Consumption connected Remarks WorkingType, RPM SST. fCond. Motor fStandby
Make &Model TemD fOC) (kW) (kW) (kW) .
Full load:
Part load:
xiv) Condenser Details.Condenser: t Qty Operating Condenser Electric Fan Total Remarks. Working
Type, Make &; Parameters Heat fPump Motor Electric fStandbyModel Condensing Rejection Rating Power
: Temp.(CT) Capa~ity (kW) (kW), WBT, water infout (kW),temDfOC)
Fan& PumpCapacity
(CMHfLPS) &Motor k
TotalElectricPower
k
Remarks WorkingfStandby
xvi) Pressure VesselsDescription Type Refrigerant' Operating ConstrUction-
-_._- -Total
--Holding Volume
Horizontal Temp&. Shell, Dish Refrigerationor Pressure- Ends &Nozzles loadVertical - --
LowPressure
HighPressure
Note:The design and testing of the pressure vessel should comply with ASMESec VIIIDiv 1.
xviiACUType,Make &Model
MateriillofCoil Tubes&Fins
Fin pitch(mm)
Total FanElectric
Power (kW)
'TO - Temperature difference between Evap. (SST) 0C& Return Air (at coil inlet).Ii
Note: Please! attach Detailed Technical Performance Data Sheets of each equipment namelyCompressors, Condensers. Cooling Towers, Air Cooling Units giving General Layout andDimensions ~uly Certified by the respective equi pment manufacturers with reference to theRelevant Codes & Standards. .
xviii) Electrical Installation:Total Connected load (kWlEstimated power requirement atPeak Load Period (kW)Estimated power requirement atHoldin~ Load Period (kWlEstimated power requirement at LeanLoad Period (kWlCapacity ofTransformer(kVA)
Size of Capacitor
Make & Capacity of standby D.G. SetsI
(nos and kVA)!,
xix) Material Handlin!! procedure-- I'rocedure
'v." Brief Description- - ~_..
Material Handling Procedures& Equipment
Capacity of mechanised beltconveyor (kW) if any-Rating ofmotor
Any other devices, please specify
Attach a Plan& Layout of the proposed ColdStore unit approved by a Registered Architect
xx) Safety Provisions: MandatoryhInclude Mac ine room ventilation svstem for self.containinl!
~",;;"'1,'" ';;,1"5,'m';;,Yes I,No;;","'''' ,o,oF '; ;t;~'"rHFire Fighting equipment as per Firesafety standards of State FireDenartment installedRefrigerant Leak detections system
Safety devices - LP/HP cut outs,safety valves, 'shut off valves etc.installedEmergency lighting in Cold chambers& other areas installedLightening arreftors installed
Any other safety provisions installed(describe)
'i'BriefDescri tioll.uld s;iViii's,;i
Natural Lighting for general areas
VFD / Electronic Technology for fans /compressors
Refrigerant Controls and Automation
Air Purger
Power Factor Controller
Energy recovery