Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
ACCOMMODATION BLOCK & WALKWAYS
End view of modules. 10.3m Accommodation Modules
GENERAL SPECIFICATION:
Fire Rating: A60 Rated
Design: DNV 2.7-1 / DNV 2.7-3 /EN12079- IMO & SOLAS compliant
Area Classification: Suitable for either Safe Area or Hazardous Area (Zone 11)
Dimensions: 10.3m L x 3.3m W x 3.3m H (34ft x 11ft x 11ft)
Weight: 16 tonnes
Electrical Supplies: 440v, 60Hz, 3 phase (normal & emergency supply)
254v, 60Hz, 1 phase (emergency supply)
Socket supply: 240v / 220v / 110v
Layout: Level 1 & 2 floors: provides eight 3 person cabins with
dedicated wet units ( Four modules.)
Levels 3 & 4 floors: provides one 3 person office and
Open plan office space for ten persons capability and the
Fourth floor offers Gym and Television/Games Room.
4 off completely enclosed, pressurised internal stairwell
Modules (stairs complete with handrails)
There are external walkways provided –see drawings
All modules are designed for ‘plug and play’ tie-in’s
Piping connections: Black and Grey water drainage, Potable water supply,
ACCOMMODATION BLOCK & WALKWAYS Firewater supply, Sprinklers comply with NFPA 13
Standard, Roof drains, and Instrument air (DNV-2-7-1 /IP54)
Electrical connections: Normal plus standby / emergency power supplies,
Main isolator, stand alone Fire & Gas panel etc, Fire JB,
Flow switch, PA/GA JB, Fan trip JB, TV JB, Telephone/Data,
Condenser isolator x 2, and Public address system
HVAC system: Air cooled Single centralised duty / standby HVAC system to
supply the Accommodation Block (12 off modules)
Power Supply: 440v, 60Hz, 3 phase, 4 wires to each module.
Operating at: +25.6 D c 90% RH & -7.4 D c 100% RH
Interior cabin temperature: + 21 D c adjustable, + or -3 D c
to each 2 person cabin
Conforms to EU directive: 94/9/EC ‘ATEX’ for use in a Zone 1
(2G) Gas Group 11A temp class T3 hazardous area.
Modules HVAC will maintain a 50 Pa differential pressure
Ventilation system will provide positive pressurisation
HVAC Unit in warehouse HVAC Skid with external ducting
ACCOMMODATION BLOCK & WALKWAYS
4 Levels high stacked modules and walkways –side views
Side and End view of Stairwell Modules -4 off in total.
ACCOMMODATION BLOCK & WALKWAYS
Three Person cabin interior View showing single bed & desk
INTERNAL PHOTOGRAPHS -3 PERSON CABINS
Three Person cabin interior Cabin Wet Unit
ACCOMMODATION BLOCK & WALKWAYS
Stairwell Level 1/2 Stairwell Level 1-Main Power
INTERNAL PHOTOGRAPHS – STAIRWELL MODULES
Stairwell Level 2 Plant Rooms Stairwell Level 4
ACCOMMODATION BLOCK & WALKWAYS
Level 3 & 4 (Stairwell toilets) Tea Prep Area open plan-level 3
AIKEN GROUP WEBSITE: www.aikengoup.com