Gillette Generators, Inc. •••• 2921 Thorne Dr. •Elkhart, IN • 46514 • Ph: 574-264-9639 • Fax: 574-262-1840 • Web: www.gillettegenerators.com • spc4-190719 1
60 HZ MODEL
SPJD-1550 LIQUID COOLED DIESEL ENGINE GENERATOR SET
GENERATOR RATINGS
GENERATOR
MODEL
VOLTAGE PH HZ
120°°°°C RISE STANDBY RATING POWER LEAD
CONNECTIONS L-N L-L KW/KVA AMP
SPJD-1550-1-1 120 240 1 60 155/155 646 4 LEAD DEDICATED 1 PH
SPJD-1550-3-2 120 208 3 60 151/188.8 525 12 LEAD LOW WYE
SPJD-1550-3-3 120 240 3 60 151/188.8 455 12 LEAD HIGH DELTA
SPJD-1550-3-4 277 480 3 60 155/193.8 233 12 LEAD HIGH WYE
SPJD-1550-3-5 127 220 3 60 151/188.8 496 12 LEAD LOW WYE
SPJD-1550-3-16 346 600 3 60 155/193.8 186 4 LEAD DEDICATED 3 PH
RATINGS: All single phase gen-sets are dedicated 4 lead windings, rated at unity (1.0) power factor. All three phase gen-sets are 12 lead windings, rated at .8 power factor. 120° C “STANDBY RATINGS” are strictly for gen-sets that are used for back-up emergency power to a failed normal utility power source. This standby rating allows varying loads, with no overload capability, for the entire duration of utility power outage. All gen-set power ratings are based on temperature rise measured by resistance method as defined by MIL-STD 705C and IEEE STD 115, METHOD 6.4.4. All generators have class H (180°C) insulation system on both rotor and stator windings. All factory tests and KW/KVA charts shown above are based 120°C (standby) R/R winding temperature, within a maximum 40°C ambient condition. Generators operated at standby power ratings must not exceed the temperature rise limitation for class H insulation system, as specified in NEMA MG1-22.40. Specifications & ratings are subject to change without prior notice.
Model STANDBY
120ºC RISE HZ
SPJD-1550-60 HERTZ 60 151/155
“OPEN” GEN-SET
There is no enclosure, so gen-set must be placed within a weather protected area, un-inhabited by humans or animals, with proper ventilation. Silencer not supplied, as installation requirements are not known. However, this item is available as optional equipment.
“LEVEL 2” HOUSED GEN-SET
Full aluminum weather protection and superior sound attenuation for specific low noise applications. Critical grade muffler is standard.
All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested.
UL2200, UL1446, UL508, UL142, UL498
NFPA 110, 99, 70, 37 All generator sets meet NFPA-110 Level 1, when equipped with the necessary accessories and installed per NFPA standards.
NEC 700, 701, 702, 708 NEMA ICS10, MG1, ICS6, AB1 ANSI C62.41, 27, 59, 32, 480, 40Q, 81U, 360-05 ASCE 7-05 & 7-10
All generator sets meet 180 MPH rating. EPA 40CFR Part 60, 1048, 1054, 1065, 1068
Gillette Generators, Inc. •••• 2921 Thorne Dr. •Elkhart, IN • 46514 • Ph: 574-264-9639 • Fax: 574-262-1840 • Web: www.gillettegenerators.com • spc4-190719 2
GENERATOR SPECIFICATIONS
Manufacturer ................................... Stamford Electric Generators Model & Type ........... UCI274H-06, 4 Pole, 4 Lead, Single Phase ....... UCI274G-311, 4 Pole, 12 Lead re-connectable, Three Phase ........................ UCI274F-17, 4 Pole, 6 Lead, 600 V, Three Phase Exciter ..................................................... Brushless, shunt excited Voltage Regulator ....................................... Solid State, HZ/Volts Voltage Regulation ................................ ½%, No load to full load Frequency ............................................................................ 60 HZ Frequency Regulation ........ ± ½% (1/2 cycle, no load to full load) Unbalanced Load Capability ..................... 100% of standby amps Total Stator and Load Insulation ........................... Class H, 180°C Temperature Rise ......... 120°C R/R, standby rating @ 40°C amb. 1 Ø Motor Starting @ 30% Voltage Dip (240V) ............ 560 kVA 3 Ø Motor Starting @ 30% Voltage Dip (208-240V) ..... 580 kVA 3 Ø Motor Starting @ 30% Voltage Dip (480V) ............ 740 kVA 3 Ø Motor Starting @ 30% Voltage Dip (600V) ............ 665 kVA Bearing ..................................................... 1, Pre-lubed and sealed Coupling .......................................................... Direct flexible disc Total Harmonic Distortion ............... Max 3½% (MIL-STD705B) Telephone Interference Factor ............ Max 50 (NEMA MG1-22) Deviation Factor ................................. Max 5% (MIL-STD 405B) Ltd. Warranty Period .................. 24 Months from start-up date or ........................................................ 1000 hours use, first to occur
ENGINE ___________________________________
Manufacturer ............................................................... John Deere Model and Type .................... 6068HF285, 4 cycle, liquid Cooled Aspiration ................................................................ Turbocharged Charged Air Cooled System ……………….………… Air to Air Cylinder Arrangement ................................... 6 Cylinders, In-Line Displacement Cu. In. (Liters) .......................................... 415 (6.8) Bore & Stroke In. (Cm.) .............................. 4.19 x 5 (10.6 x 12.7) Compression Ratio .............................................................. 19.0:1 Main Bearings & Style .............................Tin-Aluminum, Babbitt Cylinder Head ................................................................. Cast Iron Pistons ............................................................ 6, Aluminum Alloy Crankshaft ................................................... Forged Chrome Steel Exhaust Valve ................................... Forged Heat Resistant Steel Governor ............................... JDEC Electronic L16 DENSO HP3 Frequency Regulation ........................................................ ± 1/4% Air Cleaner ......................................... Dry, Replaceable Cartridge Engine Speed ................................................................. 1800 rpm Max Power, bhp (kwm) Standby .................. ................ 237 (177) BMEP: psi (kpa) Standby ............................. .............. 252 (1735) Ltd. Warranty Period ........... 24 months or 2000 hrs, first to occur
FUEL SYSTEM ____________________________
Type ......................................... Diesel Fuel Oil (ASTM No. 2-D) Combustion System ............................................. Direct Injection Fuel Injection Pump ................................. Stanadyne Rotary Type 12 VDC air intake heaters ............................. Standard Equipment Fuel Filter and Water Separator……………………………Yes
GENERATOR FEATURES
• World Renown Stamford Electric Generator having UL-1446 certification.
• Full generator protection with Deep Sea 7420 controller, having UL-508 certification.
• Automatic voltage regulator with over-excitation, under-frequency compensation, under-speed protection, and EMI filtering. Entire solid-state board is encapsulated for moisture protection.
• Generator power ratings are based on temperature rise, measured by resistance method, as defined in MIL-STD 705C and IEEE STD 115, Method 6.4.4.
• Power ratings will not exceed temperature rise limitation for class H insulation as per NEMA MG1-22.40.
• Insulation resistance to ground, exceeds 1.5 meg-ohm. • Stator receives 2000 V. hi-potential test on main windings,
and rotor windings receive a 1500 V. hi-potential test, as per MIL-STD 705B.
• Full amortisseur windings with UL-1446 certification. • Complete engine-generator torsional acceptance, confirmed
during initial prototype testing.
• Full load testing on all engine-generator sets, before shipping. • Self ventilating and drip-proof & revolving field design
FUEL CONSUMPTION
GAL/HR (LITER/HR) STANDBY
100% LOAD 12.1 (45.8) 75% LOAD 9.4 (35.6) 50% LOAD 6.2 (23.5)
OIL SYSTEM
Type ......................................................................... Full Pressure Oil Pan Capacity qt. (L) ..................................................25 (23.9) Oil Pan Cap. W/ filter qt. (L) ..........................................26 (24.6) Oil Filter .................................................. 1, Replaceable Spin-On
ELECTRICAL SYSTEM _____________________
Ignition System ............................................................. Electronic Eng. Alternator/Starter: 12 VDC, negative ground, 65 amp/hr.
Recommended Battery to -18°C (0°F): ... 12 VDC, Size BCI# 27, Max Dimensions: ........ 12" lg X 6 3/4” wi X 9" hi, with standard round posts. Min output at 700 CCA. Battery tray (max. dim. at 12”lg x 7”wi), hold down straps, battery cables, and battery charger, is furnished. Installation of (1) starting battery is required, with possible higher AMP/HR rating, as described above, if normal environment averages -13°F (-25°C) or cooler.
CERTIFICATIONS
All engines are CARB and EPA emissions certified. All stationary diesel engines are Tier III compliant.
APPLICATION AND ENGINEERING DATA FOR MODEL SPJD-1550-60 HZ
ENGINE SPECIFICATIONS AND APPLICATIONS DATA
Gillette Generators, Inc. •••• 2921 Thorne Dr. •Elkhart, IN • 46514 • Ph: 574-264-9639 • Fax: 574-262-1840 • Web: www.gillettegenerators.com • spc4-190719 3
COOLING SYSTEM
Type of System ............................ Air to Air, Charged Air Cooler Coolant Pump ..................................... Pre-lubricated, self-sealing Cooling Fan Type (no. of blades) ................................. Pusher (7) Fan Diameter inches (cm) ............................................. 22" (55.9) Ambient Capacity of Radiator °F (°C) .......................... 125 (51.6) Engine Jacket Coolant Capacity Qt. (L) ......................... 13 (12.3) Radiator Coolant Capacity Qt. (L) .................................. 24 (22.7) Water Pump Capacity gpm (L/min) .............. ............... 48 (181.7) Heat Reject Coolant: Btu/min (kw) ............. ............. 5324 (93.5) Air to Air Heat Reject(kw) .......................... ................ 1821 (32) Low Radiator Coolant Level Shutdown……………...…Standard Note: Coolant temp. shut-down switch setting at 212°F (100°C) with 50/50 (water/antifreeze) mix.
COOLING AIR REQUIREMENTS
Combustion Air cfm (m3/min) ...................... ............... 480 (13.6) Max Air Intake Restrictions: Clean Air Cleaner, H2O (KPa) ............... ................. 15 (3.75) Intake Manifold Pressure, Psi (kPa) .............. ................. 27 (187) Max. Allowable Temp. Rise, Amb. Air to Eng. Inlet, °F (°C) ....................... ................. …15 (8) Max. Temp. out of Charger Air Cooler @ 77° F (25°C), Amb. Air °F (°C) ........ ................. 140 (60) Radiator Cooling Air, SCFM (m3/min)………….....8000 (226.5)
EXHAUST SYSTEM Exhaust Outlet Size ................................................................. 3.5" Max. Back Pressure in H2O (kpa) ..................................... 30 (7.5) Exhaust Flow, at rated KW, cfm (m3/min) ... ................ 1201 (34) Exhaust Temp, at rated KW, °F (ºC)............. ................ 941 (505)
Deep Sea 7420
The “7420” controller is an auto start mains (utility) failure module for single gen-set applications. This controller includes a backlit LCD display which continuously displays the status of the engine and generator at all times.
The “7420” controller will also monitor speed, frequency, voltage, current, oil pressure, coolant temp., and fuel levels. These modules have been designed to display warning and shut down status. It also includes: (11) configurable inputs • (8) configurable outputs • voltage monitoring • mains (utility) failure detection • (250) event logs • configurable timers • automatic shutdown or warning during fault detection • remote start (on load) • engine preheat • advanced metering capability • hour meter • text LCD displays • protected solid state outputs • test buttons for: stop/reset • manual mode • auto mode • lamp test • start button • power monitoring (kWh, kVAr, kVAh, kVArh)
SOUND LEVELS MEASURED IN dB(A) Open Level 2 Set Encl. Level 2, Critical Silencer ......................... 84............ ........... 75 Level 3, Hospital Silencer ........................................ ........... 70
Note: Open sets (no enclosure) have silencer system choices due to unknown job-site applications. Level 2 enclosure has installed critical silencer with upgrade to Level 3 hospital silencer. Sound tests are averaged from several test points and taken at 23 ft. (7 m) from source of noise at normal operation.
DERATE GENERATOR FOR ALTITUDE
3% per 1000 ft.(305 meters) above 3000 ft. (914 meters) from sea level.
DERATE GENERATOR FOR TEMPERATURE
2% per 10°F (12°C) above 104°F (40°C)
DIMENSIONS AND WEIGHTS Open Level 2 Set Enclosure Length in (cm) ......................... 110 (280) ..... ................ 134 (341) Width in (cm) ........................... 48 (122) ...... ................. 48 (122) Height in (cm) .......................... 55 (140) ...... ............... 72.5 (183) 1 Ø Net Weight lbs (kg) ........ 3269 (1483) ... ............ 4319 (1959) 1 Ø Ship Weight lbs (kg) ...... 3429 (1555) ... ............ 4644 (2106) 3 Ø Net Weight lbs (kg) ........ 3209 (1455) ... ............ 4169 (1891) 3 Ø Ship Weight lbs (kg) ...... 3459 (1568) ... ............ 4489 (2036)
This controller includes expansion features including RS232, RS484 (using MODBUS-RTU/TCP), direct USB connection with PC, expansion optioned using DSENet for remote annunciation and remote relay interfacing for a distance of up to 3300FT. The controller software is freely downloadable from the internet and allows monitoring with direct USB cable, LAN, or by internet via the built in web interface.
Further expansion is available by adding the optional “WebNet“ gateway interface module. This device will allow comprehensive monitoring of the generator via the cloud including identification, location, and status. Some advantages of this module include: reduced site visits and maintenance costs • remote fuel management • fault analysis • asset tracking • automatic system alerts • maximized system up-time.
APPLICATION AND ENGINEERING DATA FOR MODEL SPJD-1550-60 HZ
DEEP SEA 7420 DIGITAL MICROPROCESSOR CONTROLLER
Gillette Generators, Inc. •••• 2921 Thorne Dr. •Elkhart, IN • 46514 • Ph: 574-264-9639 • Fax: 574-262-1840 • Web: www.gillettegenerators.com • spc4-190719 4
CONTROL PANEL: Deep Sea 7420 digital microprocessor with logic allows programming in the field. Controller has: • STOP-MANUAL-AUTO modes and automatic engine
shutdowns, signaled by full text LCD indicators: • Low oil pressure Engine fail to start • High engine temp Engine over speed Low Radiator Level Engine under speed Three auxiliary alarms Over & under voltage Battery fail alarm
Also included is tamper-proof engine hour meter
ENGINE:
Full flow oil filter • Air filter • Oil pump • Solenoid type starter motor • Hi-temp radiator • Jacket water pump • Thermostat • Pusher fan and guard • Exhaust manifold • 12 VDC battery charging alternator • Flexible exhaust connector • ”Isochronous” duty, electronic governor • Vibration isolators • Closed coolant recovery system with 50/50 water to anti-freeze mixture • flexible oil & radiator drain hose.
AC GENERATOR SYSTEM:
AC generator • Shunt excited • Brushless design • Circuit Breaker installed and wired to gen-set • Direct connection to engine with flex disc • Class H, 180°C insulation • Self ventilated • Drip proof construction • UL Certified
VOLTAGE REGULATOR:
½% Voltage regulation • EMI filter • Under-speed protection • Over-excitation protection • total encapsulation
DC ELECTRICAL SYSTEM:
Battery tray • Battery cables • Battery hold down straps • 2-stage battery float charger with maintaining & recharging automatic charge stages
WEATHER/SOUND PROOF ALUMINUM HOUSING
CORROSION RESISTANT PROTECTION CONSISTING OF:
• 9 Heated And Agitated Wash Stages • Zinc Phosphate Etching-coating Stage • Final Baked On Enamel Powder Coat • 18/8 Stainless Steel Hardware
STANDARD FEATURES FOR MODEL SPJD-1550-60 HZ
STANDARD FEATURES
Design & specifications subject to change without prior notice. Dimensions shown are approximate. Contact Gillette for certified drawings. DO NOT USE DIMENSIONS FOR INSTALLATION PURPOSES.
Engi
ne P
erfo
rman
ce C
urve
s60
68 -
Gen
erat
orO
ctob
er 2
006
Ref
: En
gine
Em
issi
on L
abel
Tier
-3 E
mis
sion
Cer
tific
atio
ns:
Cer
tifie
d by
:
Not
es:
ENG
INE
PER
FOR
MA
NC
E C
URV
E
Air I
ntak
e R
estri
ctio
n...
......
......
....1
2 in
.H2O
(3 kP
a)
Exha
ust B
ack
Pres
sure
......
.....
30 in
.H2O
(7.5
kPa
)
Gro
ss p
ower
gua
rant
eed
with
in +
or -
5%
at S
AE J
1995
an
d IS
O 3
046
cond
ition
s:77
°F (2
5 °C
) air
inle
t tem
pera
ture
29.3
1 in
.Hg
(99
kPa)
bar
omet
er10
4 °F
(40
°C) f
uel i
nlet
tem
pera
ture
0.85
3 fu
el s
peci
fic g
ravi
ty @
60
°F (1
5.5
°C)
Con
vers
ion
fact
ors:
Pow
er:
kW =
hp
x 0.
746
Fuel
: 1
gal =
7.1
lb,
1 L
= 0.
85 k
gTo
rque
: N
•m =
lb-ft
x 1
.356
All v
alue
s ar
e fro
m c
urre
ntly
ava
ilabl
e da
ta a
nd a
re s
ubje
ct
to c
hang
e w
ithou
t not
ice.
STAN
DAR
D C
ON
DIT
ION
S
All O
EM G
en S
et E
ngin
e Ap
plic
atio
ns m
ust
be p
re-
scre
ened
for
tors
iona
l vib
ratio
n co
mpa
tibilit
y w
ith th
ere
spec
tive
alte
rnat
or e
nd h
ardw
are.
OEM
Eng
ine
Appl
icat
ion
Engi
neer
ing
will
perfo
rm th
isco
mpu
ter-b
ased
ana
lysis
wor
k up
on re
ques
t.
- PR
IME
- STA
ND
BY
70 (32) 50 (23) 30 (14)
Fuel -- lb/hr (kg/hr)
20 (15)
220
(164
)26
0(1
90)
140
(104
)18
0(1
34)
60 (45)
100
(75) B
rake
Pow
er --
hp
(kW
)
300
(224
)
Pow
erTe
ch E
TM 6
.8L
Engi
neM
odel
: 606
8HF2
85
216
hp (1
61 k
W) P
rime
237
hp (1
77 k
W) S
tand
by
[See
Opt
ion
Cod
e Ta
bles
]
Rat
ing:
Gro
ss P
ower
Appl
icat
ion:
Gen
erat
or (6
0 H
z)Ta
rget
:15
0 kW
e St
andb
y M
arke
t
* Rev
ised
Dat
aC
urve
606
8HF2
8518
0023
7...
......
......
......
......
..She
et 1
of 2
Oct
ober
200
6
Nom
inal
Eng
ine
Pow
er @
180
0 RP
M
Prim
eSt
andb
y
HP
kWH
PkW
216
161
237
177
Gen
erat
or
Effic
ienc
y %
Fan
Pow
er(6
% o
f Sta
ndby
)Po
wer
Fa
ctor
Prim
e R
atin
g 2
Stan
dby
Rat
ing
1,2
ISO
852
8 G
2 Bl
ock
Load
C
apab
ility
hpkW
kWe
kVA
kWe
kVA
88-9
213
.19.
80.
813
3-13
916
6-17
414
7-15
418
4-19
3N
AN
ote
1: B
ased
on
nom
inal
eng
ine
pow
er. D
erat
e 20
% fo
r 100
% b
lock
load
cap
abilit
y.N
ote
2: k
We
/ kVA
ratin
g as
sum
es 9
0% e
ffici
ency
. “G
ener
ator
Effi
cien
cy %
” will
vary
.
CA
RB
; EPA
Engi
ne P
erfo
rman
ce C
urve
s60
68 -
Gen
erat
orN
ovem
ber 2
006
All v
alue
s at
rate
d sp
eed
and
pow
er w
ith s
tand
ard
optio
ns u
nles
s ot
herw
ise
note
d.
Engi
ne In
stal
latio
n C
riter
iaG
ener
al D
ata
Mod
el...
......
......
......
......
......
......
......
......
......
......
6068
HF2
85N
umbe
r of C
ylin
ders
......
......
......
......
......
......
......
......
......
...6
Bore
and
Stro
ke--i
n. (m
m)..
......
......
4.19
x 5
.00
(106
x 1
27)
Dis
plac
emen
t--in
.3 (L).
......
......
......
......
......
......
......
415
(6.8
)C
ompr
essi
on R
atio
......
......
......
......
......
......
......
......
...19
.0:1
Valv
es p
er C
ylin
der--
Inta
ke/E
xhau
st...
......
......
......
......
.2 /
2Fi
ring
Ord
er...
......
......
......
......
......
......
......
......
....1
-5-3
-6-2
-4C
ombu
stio
n Sy
stem
......
......
......
......
......
......
...U
nit I
njec
tion
Engi
ne T
ype.
......
......
......
......
......
......
......
.....
In-li
ne, 4
-Cyc
leAs
pira
tion.
......
......
......
......
......
......
......
......
.....T
urbo
char
ged
Cha
rge
Air C
oolin
g Sy
stem
......
......
......
......
......
.....A
ir-to
-Air
Engi
ne C
rank
case
Ven
t Sys
tem
......
......
......
......
......
..O
pen
Phys
ical
Dat
aLe
ngth
--in.
(mm
)....
......
......
......
......
......
......
......
.44.
2 (1
123)
Wid
th--i
n. (m
m).
......
......
......
......
......
......
......
......
..25.
9 (6
57)
Hei
ght--
in. (
mm
)....
......
......
......
......
......
......
......
..40.
8 (1
036)
Wei
ght,
with
oil-
-lb (k
g)...
......
......
......
......
......
......
1340
(608
) (In
clud
es fl
ywhe
el h
sg.,
flyw
heel
& e
lect
rics)
Cen
ter o
f Gra
vity
Loc
atio
n (E
stim
ated
bas
ed o
n Ti
er 2
)Fr
om R
ear F
ace
of B
lock
(X-a
xis)
--in.
(mm
).14
.5 (3
69)
Rig
ht o
f Cra
nksh
aft (
Y-ax
is)--
in. (
mm
)....
......
......
0.1
(3)
Abov
e C
rank
shaf
t (Z-
axis
)--in
. (m
m).
......
......
.6.1
(154
)M
ax. A
llow.
Sta
tic B
endi
ng M
omen
t at R
ear
Face
of F
lyw
hl H
sg w
/ 5-G
Loa
d--lb
-ft (N
•m).
.600
(814
)Th
rust
Bea
ring
Load
Lim
it --l
b (N
)Fo
rwar
dR
earw
ard
Inte
rmitt
ent..
......
......
......
......
..899
(400
0)...
..450
(200
0)C
ontin
uous
......
......
......
......
...49
5 (2
200)
.....2
25 (1
000)
Max
. Fro
nt o
f Cra
nk. T
orsi
onal
Vib
ratio
n--D
DA
......
......
0.25
Max
. Con
tinuo
us D
ampe
r Tem
p--°
F (°
C).
......
......
..180
(82)
Elec
tric
al S
yste
m12
Vol
t24
Vol
tM
in. B
atte
ry C
apac
ity (C
CA)
--am
p....
......
..800
......
......
570
Max
. Allo
w. S
tart.
Circ
’t R
esis
t.--O
hm..0
.001
2...
......
0.00
2St
arte
r Rol
ling
Cur
rent
:At
32
°F (
0 °C
)--am
p...
......
......
......
......
.920
......
......
600
At -2
2 °F
(-30
°C)--
amp.
......
......
......
....1
300
......
......
700
Min
. Vol
ts a
t EC
U w
hile
Cra
nkin
g--v
olts
......
...6
......
......
..10
Max
. EC
U T
empe
ratu
re--°
F (°
C).
......
......
.....2
21 (1
05)
Max
. Har
ness
Tem
pera
ture
--°F
(°C
)....
......
..248
(120
)M
axim
um V
olta
ge F
rom
Eng
ine
Cra
nksh
aft/
Gen
erat
or S
haft
to G
roun
d--V
AC*.
......
..0.1
5*...
......
0.15
*
Air
Syst
emPr
ime
Stan
dby
Max
. Allo
wab
le T
emp
Ris
e--A
mbi
ent A
ir to
Engi
ne In
let--
°F (°
C)..
......
......
......
......
......
.....1
5 (8
)M
axim
um A
ir In
take
Res
trict
ion
Dirt
y Ai
r Cle
aner
--in.
H2O
(kPa
).....
......
....2
5 (6
.25)
Cle
an A
ir C
lean
er--i
n.H
2O (k
Pa)..
......
.....1
5 (3
.75)
Engi
ne A
ir Fl
ow--f
t3 /m
in (m
3 /m
in).
...47
0 (1
3.3)
..480
(13.
6)Ai
r Cle
aner
Effi
cien
cy--%
......
......
......
......
......
...99
.9
Cha
rge
Air
Coo
ling
Syst
emPr
ime
Stan
dby
Air/A
ir Ex
chan
ger H
eat R
ejec
tion-
-BT
U/m
in (k
W).
......
......
......
......
......
....1
702(
29.9
)...
1821
(32.
0)C
ompr
ess.
Dis
chrg
. Tem
p.(R
ated
)@
77
°F (2
5°C
) Am
b. A
ir--°
F (°
C)3
52(1
78).
...36
9(18
7)C
ompr
ess.
Dis
chrg
. Tem
p.(M
ax.)
@ 4
7°C
am
b. a
nd
80 k
Pa b
ar.--
°F (°
C).
......
......
......
...N
A (N
A)...
..NA
(NA)
Pres
s. D
rop,
thru
CAC
--in.
H2O
(kPa
)M
ax. .
......
......
......
......
......
......
......
......
......
.64
(16)
Min
. ....
......
......
......
......
......
......
......
......
......
.32
(8)
Inta
ke M
anifo
ld P
ress
ure-
-psi
(kPa
)...2
5 (1
70).
....2
7 (1
87)
CAC
Out
Tem
p @
77°
F (2
5°C
) Am
b.--°
F (°
C)
Max
. ...
......
......
......
......
......
......
......
......
.....1
40 (6
0)M
in.
......
......
......
......
......
......
......
......
......
...11
8 (4
8)C
AC O
ut T
emp
@ a
ny A
mbi
ent--
°F (°
C)
Max
.....
......
......
......
......
......
......
......
......
.....1
90 (8
8)
Coo
ling
Syst
emPr
ime
Stan
dby
Engi
ne H
eat R
ejec
t.--B
TU/m
in (k
W)..
.NA
(NA)
..53
24 (9
3.5)
Coo
lant
Flo
w--g
al/m
in (L
/min
).....
......
...48
(180
)....
..48(
180)
Ther
mos
tat S
tart
to O
pen-
-°F
(°C
)....
......
.....1
80 (8
2)Th
erm
osta
t Ful
ly O
pen-
-°F
(°C
).....
......
......
..203
(95)
Engi
ne C
oola
nt C
apac
ity--q
t (L)
......
......
.....1
3 (1
1.9)
Min
. Pre
ssur
e C
ap--p
si (k
Pa).
......
......
......
14.5
(100
)M
ax. T
op T
ank
Tem
p--°
F (°
C).
......
......
......
.230
(110
)M
in. C
oola
nt F
ill R
ate-
-gal
/min
(L/m
in).
......
.....3
(11)
M
in. A
ir-to
-Boi
l Tem
pera
ture
--°F
(°C
)....
......
117
(47)
Min
. Pum
p In
let P
ress
ure-
-psi
(kPa
).....
......
..4.4
(30)
Exha
ust S
yste
mPr
ime
Stan
dby
Exha
ust F
low
--ft3 /
min
(m3 /
min
).....
.116
5 (3
3.0)
.120
1(34
.0)
Exha
ust T
empe
ratu
re--°
F (°
C).
......
...91
6 (4
91).
..941
(505
)M
ax. E
xhau
st R
estri
ctio
n----
in. H
2O (k
Pa)..
....3
0 (7
.5)
Min
. Exh
aust
Res
trict
ion-
---in
. H2O
(kPa
).....
......
Non
eM
ax. B
end.
Mom
ent,
Turb
o O
ut.--
lb-ft
(N•m
).5.
2 (7
.0)
Max
. She
ar o
n Tu
rbo
Out
let--
lb (k
g)...
......
......
.24
(11)
Fuel
Sys
tem
Prim
eSt
andb
yEC
U D
escr
iptio
n...
......
......
......
......
......
..L16
Con
trolle
rFu
el In
ject
ion
Pum
p ...
......
......
......
......
......
Den
so H
P3G
over
nor T
ype.
......
......
......
......
......
......
......
.Ele
ctro
nic
Tota
l Fue
l Flo
w--l
b/hr
(kg/
hr)..
......
...18
5(84
.0).
....2
01(9
1.2)
Fuel
Con
sum
ptio
n--lb
/hr (
kg/h
r)...
......
..77(
35).
......
..84
(38)
Max
. Fue
l Inl
et T
emp.
--°F
(°C
)....
......
......
......
.176
(80)
Fuel
Tem
p. R
ise,
Inlt
to R
etrn
--°F
(°C
)75.
6(42
)....
....8
1(45
)M
ax. F
uel I
nlet
Res
trict
ion-
-in. H
2O (k
Pa).
......
80 (2
0)M
ax. F
uel I
nlet
Pre
ssur
e--in
. H2O
(kPa
)....
....N
A (N
A)M
ax. F
uel R
etur
n Pr
essu
re--i
n. H
2O (k
Pa).
.....8
0 (20
)
Lubr
icat
ion
Syst
emPr
ime
Stan
dby
Oil
Pres
s. a
t Rat
ed S
peed
--psi
(kPa
).44
(300
)....
.44
(300
)M
in.O
il Pr
essu
re--p
si (k
Pa)..
......
......
......
......
..15
(105
)M
ax. O
il C
arry
over
in B
low
-by-
-lb/h
r (g/
hr)0
.002
(1.0
)M
ax. A
irflo
w in
Blo
w-b
y--g
al/m
in (l
/min
).....
....3
4 (1
30)
Max
. Cra
nkca
se P
ress
ure-
-in. H
2O (k
Pa)..
......
.2 (0
.5)
Perf
orm
ance
Dat
aPr
ime
Stan
dby
Rat
ed P
ower
--hp
(kW
)....
......
......
...21
6 (1
61)..
....2
37 (1
77)
Rat
ed S
peed
--rpm
......
......
......
......
......
..18
00...
......
....1
800
Low
Idle
Spe
ed--r
pm...
......
......
......
......
..115
0....
......
....1
150
Rat
ed T
orqu
e--lb
-ft (N
•m)..
......
.....
1158
(854
)....1
273
(939
)BM
EP--p
si (k
Pa).
......
......
......
......
.229
(157
8)...
.252
(173
5)Fr
ictio
n Po
wer
@
Rat
ed S
peed
--hp
(kW
)....
......
....2
3 (1
7)...
......
.23
(17)
Altit
ude
Cap
abilit
y--ft
(m).
......
......
10,0
00(3
050)
...10
,000
(305
0)R
atio
--Air
: Fue
l.....
......
......
......
......
......
.25
: 1...
......
...24
: 1
Smok
e @
Rat
ed S
peed
--Bos
ch N
o....
...0.
43...
......
.....
0.74
Noi
se--d
B(A)
@ 1
m...
......
......
......
......
.....
NA.
......
......
...N
A
Fuel
Con
sum
ptio
n --
lb/h
r (kg
/h)
Prim
eSt
andb
y
25 %
Pow
er...
......
......
......
......
......
..NA
(NA)
......
24.3
(11.
0)50
% P
ower
......
......
......
......
......
.....N
A (N
A)...
...47
.4 (2
1.5)
75 %
Pow
er...
......
......
......
......
......
..NA
(NA)
......
65.0
(29.
5)10
0 %
Pow
er...
......
......
......
......
......
NA
(NA)
......
83.8
(38.
0)
* Rev
ised
Dat
aC
urve
606
8HF2
8518
0023
7....
......
......
......
......
....S
heet
2 o
f 2O
ctob
er 2
006
APPRO
VED D
OC
UM
ENT
UCI274H - Winding 06
Technical Data Sheet
APPRO
VED D
OC
UM
ENT
UCI274HSPECIFICATIONS & OPTIONS
STANDARDSStamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of otherinternational standards such as BS5000, VDE 0530,NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.
VOLTAGE REGULATORS
SX460 AVR - STANDARDWith this self excited control system the main statorsupplies power via the Automatic Voltage Regulator (AVR)to the exciter stator. The high efficiency semiconductors ofthe AVR ensure positive build-up from initial low levels ofresidual voltage.The exciter rotor output is fed to the main rotor through athree phase full wave bridge rectifier. This rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit.
AS440 AVRWith this self-excited system the main stator providespower via the AVR to the exciter stator. The highefficiency semi-conductors of the AVR ensure positivebuild-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through athree-phase full-wave bridge rectifier. The rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permitparallel operation with other ac generators.
TERMINALS & TERMINAL BOX
Dedicated Single Phase windings have 4 ends brought outto the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It hasremovable panels for easy access.
SHAFT & KEYS
All generator rotors are dynamically balanced to betterthan BS6861:Part 1 Grade 2.5 for minimum vibration inoperation. Two bearing generators are balanced with a halfkey.
INSULATION/IMPREGNATION
The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanicalstrength required for rotating components.
QUALITY ASSURANCE
Generators are manufactured using production procedureshaving a quality assurance level toBS EN ISO 9001.
The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any changein performance will fall within the limits of Criteria 'B' of EN61000 6 2:2001 At no time will the steady state voltage
STANDARDSStamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of otherinternational standards such as BS5000, VDE 0530,NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.
VOLTAGE REGULATORS
SX460 AVR - STANDARDWith this self excited control system the main statorsupplies power via the Automatic Voltage Regulator (AVR)to the exciter stator. The high efficiency semiconductors ofthe AVR ensure positive build-up from initial low levels ofresidual voltage.The exciter rotor output is fed to the main rotor through athree phase full wave bridge rectifier. This rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit.
AS440 AVRWith this self-excited system the main stator providespower via the AVR to the exciter stator. The highefficiency semi-conductors of the AVR ensure positivebuild-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through athree-phase full-wave bridge rectifier. The rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permitparallel operation with other ac generators.
MX341 AVRThis sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the main exciter,giving a source of constant excitation power independentof generator output. The main exciter output is then fed tothe main rotor, through a full wave bridge, protected by asurge suppressor. The AVR has in-built protection againstsustained over-excitation, caused by internal or externalfaults. This de-excites the machine after a minimum of 5seconds.An engine relief load acceptance feature can enable fullload to be applied to the generator in a single step.
MX321 AVRThe most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally over voltageprotection built-in and short circuit current leveladjustments as an optional facility.
WINDINGS & ELECTRICAL PERFORMANCE
All generator stators are wound to 2/3 pitch. Thiseliminates triplen (3rd, 9th, 15th …) harmonics on thevoltage waveform and is found to be the optimum designfor trouble-free supply of non-linear loads. The 2/3 pitchdesign avoids excessive neutral currents sometimes seenwith higher winding pitches, when in parallel with themains. A fully connected damper winding reducesoscillations during paralleling. This winding, with the 2/3pitch and carefully selected pole and tooth designs,ensures very low waveform distortion.
TERMINALS & TERMINAL BOX
Dedicated Single Phase windings have 4 ends brought outto the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It hasremovable panels for easy access.
SHAFT & KEYS
All generator rotors are dynamically balanced to betterthan BS6861:Part 1 Grade 2.5 for minimum vibration inoperation. Two bearing generators are balanced with a halfkey.
INSULATION/IMPREGNATION
The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanicalstrength required for rotating components.
QUALITY ASSURANCE
Generators are manufactured using production procedureshaving a quality assurance level toBS EN ISO 9001.
The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any changein performance will fall within the limits of Criteria 'B' of EN61000-6-2:2001. At no time will the steady-state voltageregulation exceed 2%.
DE RATES
All values tabulated on page 7 are subject to the followingreductions
5% when air inlet filters are fitted.3% for every 500 metres by which the operating altitudeexceeds 1000 metres above mean sea level.3% for every 5 C by which the operational ambienttemperature exceeds 40 C.
Note: Requirement for operating in an ambient exceeding60 C must be referred to the factory.
NB Continuous development of our products entitles us tochange specification details without notice, therefore theymust not be regarded as binding.
Front cover drawing typical of product range.
STANDARDSStamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of otherinternational standards such as BS5000, VDE 0530,NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.
VOLTAGE REGULATORS
SX460 AVR - STANDARDWith this self excited control system the main statorsupplies power via the Automatic Voltage Regulator (AVR)to the exciter stator. The high efficiency semiconductors ofthe AVR ensure positive build-up from initial low levels ofresidual voltage.The exciter rotor output is fed to the main rotor through athree phase full wave bridge rectifier. This rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit.
AS440 AVRWith this self-excited system the main stator providespower via the AVR to the exciter stator. The highefficiency semi-conductors of the AVR ensure positivebuild-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through athree-phase full-wave bridge rectifier. The rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permitparallel operation with other ac generators.
MX341 AVRThis sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the main exciter,giving a source of constant excitation power independentof generator output. The main exciter output is then fed tothe main rotor, through a full wave bridge, protected by asurge suppressor. The AVR has in-built protection againstsustained over-excitation, caused by internal or externalfaults. This de-excites the machine after a minimum of 5seconds.An engine relief load acceptance feature can enable fullload to be applied to the generator in a single step.
MX321 AVRThe most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally over voltageprotection built-in and short circuit current leveladjustments as an optional facility.
WINDINGS & ELECTRICAL PERFORMANCE
All generator stators are wound to 2/3 pitch. Thiseliminates triplen (3rd, 9th, 15th …) harmonics on thevoltage waveform and is found to be the optimum designfor trouble-free supply of non-linear loads. The 2/3 pitchdesign avoids excessive neutral currents sometimes seenwith higher winding pitches, when in parallel with themains. A fully connected damper winding reducesoscillations during paralleling. This winding, with the 2/3pitch and carefully selected pole and tooth designs,ensures very low waveform distortion.
TERMINALS & TERMINAL BOX
Dedicated Single Phase windings have 4 ends brought outto the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It hasremovable panels for easy access.
SHAFT & KEYS
All generator rotors are dynamically balanced to betterthan BS6861:Part 1 Grade 2.5 for minimum vibration inoperation. Two bearing generators are balanced with a halfkey.
INSULATION/IMPREGNATION
The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanicalstrength required for rotating components.
QUALITY ASSURANCE
Generators are manufactured using production procedureshaving a quality assurance level toBS EN ISO 9001.
The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any changein performance will fall within the limits of Criteria 'B' of EN61000-6-2:2001. At no time will the steady-state voltageregulation exceed 2%.
DE RATES
All values tabulated on page 7 are subject to the followingreductions
5% when air inlet filters are fitted.3% for every 500 metres by which the operating altitudeexceeds 1000 metres above mean sea level.3% for every 5 C by which the operational ambienttemperature exceeds 40 C.
Note: Requirement for operating in an ambient exceeding60 C must be referred to the factory.
NB Continuous development of our products entitles us tochange specification details without notice, therefore theymust not be regarded as binding.
Front cover drawing typical of product range.
2
APPRO
VED D
OC
UM
ENT
CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.
A.V.R. MX341 MX321
VOLTAGE REGULATION ± 1% ± 0.5 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT
CONTROL SYSTEM SELF EXCITED
A.V.R. SX460 AS440
VOLTAGE REGULATION ± 1.0 % ± 1.0 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT
INSULATION SYSTEM
PROTECTION
RATED POWER FACTOR
STATOR WINDING
WINDING PITCH
WINDING LEADS
MAIN STATOR RESISTANCE
MAIN ROTOR RESISTANCE
EXCITER STATOR RESISTANCE
EXCITER ROTOR RESISTANCE
R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others
WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING LINEAR LOAD < 5.0%
MAXIMUM OVERSPEED 2250 Rev/Min
BEARING DRIVE END BALL. 6315-2RS (ISO)
BEARING NON-DRIVE END BALL. 6310-2RS (ISO)
0.091 Ohms PER PHASE AT 22°C
WINDING 06UCI274H
0.8
IP23
CLASS H
REFER TO SHORT CIRCUIT DECREMENT CURVES (page 6)
1.82 Ohms at 22°C
20 Ohms at 22°C
SINGLE LAYER CONCENTRIC
0.007 Ohms AT 22°C SERIES CONNECTED
4
TWO THIRDS
BEARING NON-DRIVE END BALL. 6310-2RS (ISO)
1 BEARING 2 BEARING
WEIGHT COMP. GENERATOR
WEIGHT WOUND STATOR
WEIGHT WOUND ROTOR
WR² INERTIA
SHIPPING WEIGHTS in a crate
PACKING CRATE SIZE
TELEPHONE INTERFERENCE
COOLING AIR
VOLTAGE SERIES
VOLTAGE PARALLELkVA BASE RATING FOR REACTANCE VALUESXd DIR. AXIS SYNCHRONOUS
X'd DIR. AXIS TRANSIENT
X''d DIR. AXIS SUBTRANSIENT
Xq QUAD. AXIS REACTANCE
X''q QUAD. AXIS SUBTRANSIENT
XL LEAKAGE REACTANCE
X2 NEGATIVE SEQUENCE
X0 ZERO SEQUENCE
REACTANCES ARE SATURATED
T'd TRANSIENT TIME CONST. 0.042 s
T''d SUB-TRANSTIME CONST. 0.012 s
T'do O.C. FIELD TIME CONST. 1.1 s
Ta ARMATURE TIME CONST. 0.012 s
SHORT CIRCUIT RATIO 1/Xd
1.21
0.16
0.10
0.15
0.10
0.14
0.09
0.13
0.08
0.080.09
227.53 kg
1.9349 kgm2
0.13
1.44
0.19
0.12
1.32
0.17
0.11
123 x 67 x 103(cm)
TIF<50
659 kg
0.20 0.19 0.17
626 kg
253 kg
123 x 67 x 103(cm)
THF<2%
641 kg
253 kg
216.57 kg
1.8843 kgm2
673 kg
115 120110
240
156.3
0.617 m³/sec 1308 cfm
1.99
220
156.3
2.37
230
156.3
2.17
SHORT CIRCUIT RATIO 1/Xd
3
APPRO
VED D
OC
UM
ENT
UCI274HWinding 06
SINGLE PHASE EFFICIENCY CURVES
44
APPRO
VED D
OC
UM
ENT
UCI274HWinding 06
Locked Rotor Motor Starting CurvesSX
0
5
10
15
20
25
30
0 50 100 150 200 250 300 350 400 450LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
220V 230V 240V
SX
MX
0
5
10
15
20
25
30
0 50 100 150 200 250 300 350 400 450LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
220V 230V 240V
0
5
10
15
20
25
30
0 50 100 150 200 250 300 350 400 450 500 550 600LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
220V 230V 240V
55
APPRO
VED D
OC
UM
ENT
UCI274HWinding 06
Based on series connection.Short Circuit Decrement Curve. No-load Excitation at Rated Speed
Sustained Short Circuit = 2840 Amps
Note
100
1000
10000
100000
0.001 0.01 0.1 1 10TIME (secs)
CUR
REN
T (A
mps
)
SYMMETRICAL
ASYMMETRICAL
Voltage Factor220V X 1.00230V X 1.05240V X 1.09
The sustained current value is constant irrespectiveof voltage level
Sustained Short Circuit = 2840 Amps
NoteThe following multiplication factors should be used to adjust thevalues from curve between time 0.001 seconds and the minimumcurrent point in respect of nominal operating voltage :
100
1000
10000
100000
0.001 0.01 0.1 1 10TIME (secs)
CUR
REN
T (A
mps
)
SYMMETRICAL
ASYMMETRICAL
66
APPRO
VED D
OC
UM
ENT
Class - Temp Rise
Series (V) 220 230 240 220 230 240 220 230 240 220 230 240Parallel (V) 110 115 120 110 115 120 110 115 120 110 115 120
kVA 143.8 143.8 143.8 156.3 156.3 156.3 143.8 143.8 143.8 156.3 156.3 156.3
kW 115.0 115.0 115.0 125.0 125.0 125.0 143.8 143.8 143.8 156.3 156.3 156.3
Efficiency (%) 86.7 86.9 87.2 86.3 86.7 86.9 89.6 89.9 90.1 89.3 89.6 89.9
kW Input 132.6 132.3 131.9 144.8 144.2 143.8 160.5 160.0 159.6 175.0 174.4 173.9
DIMENSIONS
UCI274H
Cont. F - 105/40°C 0.8pf
Cont. H - 125/40°C 0.8pf
Cont. F - 105/40°C 1.0pf
Cont. H - 125/40°C 1.0pf
Winding 06
RATINGS60Hz60Hz
77
APPRO
VED D
OC
UM
ENT
UCI274H-06-TD-EN-SG-A
Head Office Address:Barnack Road, StamfordLincolnshire, PE9 2NB
United KingdomTel: +44 (0) 1780 484000Fax: +44 (0) 1780 484100
www.cumminsgeneratortechnologies.com
Copyright 2010, Cummins Generator Technologies Ltd, All Rights ReservedStamford and AvK are registered trade marks of Cummins Generator Technologies Ltd
Cummins and the Cummins logo are registered trade marks of Cummins Inc.
UCI274H-06-TD-EN-SG-A
Head Office Address:Barnack Road, StamfordLincolnshire, PE9 2NB
United KingdomTel: +44 (0) 1780 484000Fax: +44 (0) 1780 484100
www.cumminsgeneratortechnologies.com
Copyright 2010, Cummins Generator Technologies Ltd, All Rights ReservedStamford and AvK are registered trade marks of Cummins Generator Technologies Ltd
Cummins and the Cummins logo are registered trade marks of Cummins Inc.
APPRO
VED D
OC
UM
ENT
UCI274G - Winding 311
Technical Data Sheet
APPRO
VED D
OC
UM
ENT
UCI274GSPECIFICATIONS & OPTIONS
STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other internationalstandards such as BS5000, VDE 0530, NEMA MG1-32, IEC34,CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.
VOLTAGE REGULATORS
SX460 AVR - STANDARD
With this self excited control system the main stator suppliespower via the Automatic Voltage Regulator (AVR) to the exciterstator. The high efficiency semiconductors of the AVR ensurepositive build-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through a threephase full wave bridge rectifier. This rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit.
AS440 AVR
With this self-excited system the main stator provides power viathe AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial lowlevels of residual voltage.The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permit paralleloperation with other ac generators.
MX341 AVR
This sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the main exciter,giving a source of constant excitation power independent ofgenerator output. The main exciter output is then fed to themain rotor, through a full wave bridge, protected by a surgesuppressor. The AVR has in-built protection against sustainedover-excitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds.An engine relief load acceptance feature can enable full load tobe applied to the generator in a single step.If three-phase sensing is required with the PMG system theMX321 AVR must be used.We recommend three-phase sensing for applications withgreatly unbalanced or highly non-linear loads.
MX321 AVR
The most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally, three-phase rmssensing, for improved regulation and performance.Over voltage protection is built-in and short circuit current leveladjustments is an optional facility.
WINDINGS & ELECTRICAL PERFORMANCE
All generator stators are wound to 2/3 pitch. This eliminatestriplen (3rd, 9th, 15th …) harmonics on the voltage waveformand is found to be the optimum design for trouble-free supplyof non-linear loads. The 2/3 pitch design avoids excessiveneutral currents sometimes seen with higher winding pitches,when in parallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. This winding,with the 2/3 pitch and carefully selected pole and toothdesigns, ensures very low waveform distortion.
TERMINALS & TERMINAL BOX
Standard generators are 3-phase reconnectable with 12 endsbrought out to the terminals, which are mounted on a cover atthe non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It has removablepanels for easy access.
SHAFT & KEYS
All generator rotors are dynamically balanced to better thanBS6861:Part 1 Grade 2.5 for minimum vibration in operation.Two bearing generators are balanced with a half key.
INSULATION/IMPREGNATION
The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanical strengthrequired for rotating components.
QUALITY ASSURANCE
Generators are manufactured using production procedureshaving a quality assurance level to BS EN ISO 9001.
The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any change inperformance will fall within the limits of Criteria 'B' of EN61000-6-2:2001. At no time will the steady-state voltageregulation exceed 2%.
DE RATES
All values tabulated on page 8 are subject to the followingreductions
5% when air inlet filters are fitted.3% for every 500 metres by which the operating altitudeexceeds 1000 metres above mean sea level.3% for every 5°C by which the operational ambienttemperature exceeds 40°C.
Note: Requirement for operating in an ambient exceeding60°C must be referred to the factory. NB Continuous development of our products entitles us tochange specification details without notice, therefore theymust not be regarded as binding.
Front cover drawing typical of product range.
2
APPRO
VED D
OC
UM
ENT
CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.
A.V.R. MX321 MX341
VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT
CONTROL SYSTEM SELF EXCITED
A.V.R. SX460 AS440
VOLTAGE REGULATION ± 1.0 % ± 1.0 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT
INSULATION SYSTEM CLASS H
PROTECTION
RATED POWER FACTOR
STATOR WINDING
WINDING PITCH
WINDING LEADS
STATOR WDG. RESISTANCE
ROTOR WDG. RESISTANCE
EXCITER STATOR RESISTANCE
EXCITER ROTOR RESISTANCE
R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others
WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%
MAXIMUM OVERSPEED
BEARING DRIVE END
BEARING NON-DRIVE END
WEIGHT COMP. GENERATORWEIGHT WOUND STATORWEIGHT WOUND ROTORWR² INERTIASHIPPING WEIGHTS in a cratePACKING CRATE SIZE
TELEPHONE INTERFERENCECOOLING AIRVOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138kVA BASE RATING FOR REACTANCE VALUES 182 182 182 N/A 205 218 218 231
Xd DIR. AXIS SYNCHRONOUS 2.15 1.94 1.80 - 2.43 2.31 2.11 2.06X'd DIR. AXIS TRANSIENT 0.19 0.17 0.16 - 0.21 0.20 0.18 0.18X''d DIR. AXIS SUBTRANSIENT 0.13 0.12 0.11 - 0.15 0.14 0.13 0.12Xq QUAD. AXIS REACTANCE 1.29 1.16 1.08 - 1.47 1.40 1.28 1.24X''q QUAD. AXIS SUBTRANSIENT 0.18 0.16 0.15 - 0.18 0.17 0.16 0.15XL LEAKAGE REACTANCE 0.08 0.07 0.07 - 0.09 0.08 0.08 0.07X2 NEGATIVE SEQUENCE 0.13 0.12 0.11 - 0.16 0.15 0.13 0.13X0 ZERO SEQUENCE 0.08 0.07 0.07 - 0.10 0.09 0.08 0.08
REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATEDT'd TRANSIENT TIME CONST.T''d SUB-TRANSTIME CONST.T'do O.C. FIELD TIME CONST.Ta ARMATURE TIME CONST.SHORT CIRCUIT RATIO
REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7)
BALL. 6310-2RS (ISO)
1/Xd
0.038 s0.012 s
1 s0.01 s
1.69 Ohms at 22°C
0.0199 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED
BALL. 6315-2RS (ISO)
210.35 kg1.7674 kgm2
IP23
0.8
DOUBLE LAYER CONCENTRIC
TWO THIRDS
12
598 kg580 kg225 kg
UCI274G
0.514 m³/sec 1090 cfm 0.617 m³/sec 1308 cfm
50 HzTHF<2%
60 HzTIF<50
199.39 kg1.7169 kgm2
WINDING 311
20 Ohms at 22°C
0.091 Ohms PER PHASE AT 22°C
630 kg 123 x 67 x 103 (cm)
613 kg 123 x 67 x 103 (cm)
1 BEARING 2 BEARING
2250 Rev/Min
225 kg
3
APPRO
VED D
OC
UM
ENT
Winding 311UCI274G
THREE PHASE EFFICIENCY CURVES
50Hz
4
APPRO
VED D
OC
UM
ENT
Winding 311UCI274G
THREE PHASE EFFICIENCY CURVES
60Hz
5
APPRO
VED D
OC
UM
ENT
UCI274GWinding 311
Locked Rotor Motor Starting Curve
MX SX
50Hz
60Hz
MX SX
0
5
10
15
20
25
30
0 100 200 300 400 500 600LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
346V 380V 400V 415V
0
5
10
15
20
25
30
0 100 200 300 400 500 600 700 800LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
380V 416V 440V 460V 480V
0
5
10
15
20
25
30
0 50 100 150 200 250 300 350 400 450 500 550LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
346V 380V 400V 415V
0
5
10
15
20
25
30
0 100 200 300 400 500 600 700LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
380V 416V 440V 460V 480V
6
APPRO
VED D
OC
UM
ENT
3-phase 2-phase L-L 1-phase L-NVoltage Factor Voltage Factor x 1.00 x 0.87 x 1.30
380v X 1.00 416v X 1.00 x 1.00 x 1.80 x 3.20400v X 1.07 440v X 1.06 x 1.00 x 1.50 x 2.50415v X 1.12 460v X 1.12 10 sec. 5 sec. 2 sec.
480v X 1.17The sustained current value is constant irrespectiveof voltage level
Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated SpeedBased on star (wye) connection.
Max. sustained durationAll other times are unchanged
Instantaneous
SustainedMinimum
UCI274G
50Hz 60Hz
Sustained Short Circuit = 850 Amps
Sustained Short Circuit = 970 AmpsNote 1The following multiplication factors should beused to adjust the values from curve betweentime 0.001 seconds and the minimum currentpoint in respect of nominal operating voltage :
Note 2The following multiplication factor should be used to convert thevalues calculated in accordance with NOTE 1 to those applicableto the various types of short circuit :
Note 3Curves are drawn for Star (Wye) connected machines. For otherconnection the following multipliers should be applied to currentvalues as shown : Parallel Star = Curve current value X 2Series Delta = Curve current value X 1.732
50Hz
60Hz
10
100
1000
10000
0.001 0.01 0.1 1 10TIME (secs)
CUR
RENT
(Am
ps)
SYMMETRICAL
ASYMMETRICAL
10
100
1000
10000
0.001 0.01 0.1 1 10TIME (secs)
CUR
RENT
(Am
ps)
SYMMETRICAL
ASYMMETRICAL
7
APPRO
VED D
OC
UM
ENT
Class - Temp Rise
Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440
Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220
Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254
kVA 164.6 164.6 164.6 N/A 182.0 182.0 182.0 N/A 187.0 187.0 187.0 N/A 200.0 200.0 200.0 N/A
kW 131.7 131.7 131.7 N/A 145.6 145.6 145.6 N/A 149.6 149.6 149.6 N/A 160.0 160.0 160.0 N/A
Efficiency (%) 92.3 92.6 92.8 N/A 92.0 92.3 92.5 N/A 91.9 92.2 92.5 N/A 91.6 92.0 92.2 N/A
kW Input 142.7 142.2 141.9 N/A 158.3 157.7 157.4 N/A 162.8 162.2 161.8 N/A 174.7 173.9 173.5 N/A
Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480
Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240
Series Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277
kVA 192.8 199.0 199.0 212.2 205.0 218.5 218.5 231.4 213.0 228.8 228.8 250.0 218.5 234.0 234.0 253.3
kW 154.2 159.2 159.2 169.8 164.0 174.8 174.8 185.1 170.4 183.0 183.0 200.0 174.8 187.2 187.2 202.6
Efficiency (%) 92.4 92.7 92.9 93.0 92.2 92.4 92.7 92.7 92.0 92.2 92.5 92.5 91.9 92.1 92.4 92.5
kW Input 166.9 171.7 171.4 182.5 177.9 189.2 188.6 199.7 185.2 198.5 197.9 216.2 190.2 203.3 202.6 219.1
UCI274GWinding 311 / 0.8 Power Factor
RATINGSCont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C
DIMENSIONS
50Hz
60Hz
8
APPRO
VED D
OC
UM
ENT
UC274G-311-TD-EN-SG-A
Head Office Address:Barnack Road, StamfordLincolnshire, PE9 2NB
United KingdomTel: +44 (0) 1780 484000Fax: +44 (0) 1780 484100
www.cumminsgeneratortechnologies.com
Copyright 2010, Cummins Generator Technologies Ltd, All Rights ReservedStamford and AvK are registered trade marks of Cummins Generator Technologies Ltd
Cummins and the Cummins logo are registered trade marks of Cummins Inc.
APPRO
VED D
OC
UM
ENT
UCI274F - Winding 17
Technical Data Sheet
APPRO
VED D
OC
UM
ENT
UCI274FSPECIFICATIONS & OPTIONS
STANDARDS
Stamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of other internationalstandards such as BS5000, VDE 0530, NEMA MG1-32, IEC34,CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.
VOLTAGE REGULATORS
SX460 AVR - STANDARD
With this self excited control system the main stator suppliespower via the Automatic Voltage Regulator (AVR) to the exciterstator. The high efficiency semiconductors of the AVR ensurepositive build-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through a threephase full wave bridge rectifier. This rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit.
AS440 AVR
With this self-excited system the main stator provides power viathe AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial lowlevels of residual voltage.The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permit parallel
WINDINGS & ELECTRICAL PERFORMANCE
All generator stators are wound to 2/3 pitch. This eliminatestriplen (3rd, 9th, 15th …) harmonics on the voltage waveformand is found to be the optimum design for trouble-free supplyof non-linear loads. The 2/3 pitch design avoids excessiveneutral currents sometimes seen with higher winding pitches,when in parallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. This winding,with the 2/3 pitch and carefully selected pole and toothdesigns, ensures very low waveform distortion.
TERMINALS & TERMINAL BOX
Standard generators are 3-phase reconnectable with 12 endsbrought out to the terminals, which are mounted on a cover atthe non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It has removablepanels for easy access.
SHAFT & KEYS
All generator rotors are dynamically balanced to better thanBS6861:Part 1 Grade 2.5 for minimum vibration in operation.
INSULATION/IMPREGNATION
The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanical strengthrequired for rotating components.
STANDARDS
Stamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of other internationalstandards such as BS5000, VDE 0530, NEMA MG1-32, IEC34,CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.
VOLTAGE REGULATORS
SX460 AVR - STANDARD
With this self excited control system the main stator suppliespower via the Automatic Voltage Regulator (AVR) to the exciterstator. The high efficiency semiconductors of the AVR ensurepositive build-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through a threephase full wave bridge rectifier. This rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit.
AS440 AVR
With this self-excited system the main stator provides power viathe AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial lowlevels of residual voltage.The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permit paralleloperation with other ac generators.
MX341 AVR
This sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the main exciter,giving a source of constant excitation power independent ofgenerator output. The main exciter output is then fed to themain rotor, through a full wave bridge, protected by a surgesuppressor. The AVR has in-built protection against sustainedover-excitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds.An engine relief load acceptance feature can enable full load tobe applied to the generator in a single step.If three-phase sensing is required with the PMG system theMX321 AVR must be used.We recommend three-phase sensing for applications withgreatly unbalanced or highly non-linear loads.
MX321 AVR
The most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally, three-phase rmssensing, for improved regulation and performance.Over voltage protection is built-in and short circuit current leveladjustments is an optional facility.
WINDINGS & ELECTRICAL PERFORMANCE
All generator stators are wound to 2/3 pitch. This eliminatestriplen (3rd, 9th, 15th …) harmonics on the voltage waveformand is found to be the optimum design for trouble-free supplyof non-linear loads. The 2/3 pitch design avoids excessiveneutral currents sometimes seen with higher winding pitches,when in parallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. This winding,with the 2/3 pitch and carefully selected pole and toothdesigns, ensures very low waveform distortion.
TERMINALS & TERMINAL BOX
Standard generators are 3-phase reconnectable with 12 endsbrought out to the terminals, which are mounted on a cover atthe non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It has removablepanels for easy access.
SHAFT & KEYS
All generator rotors are dynamically balanced to better thanBS6861:Part 1 Grade 2.5 for minimum vibration in operation.
INSULATION/IMPREGNATION
The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanical strengthrequired for rotating components.
QUALITY ASSURANCE
Generators are manufactured using production procedureshaving a quality assurance level to BS EN ISO 9001.
The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any change inperformance will fall within the limits of Criteria 'B' of EN61000-6-2:2001. At no time will the steady-state voltageregulation exceed 2%.
DE RATES
All values tabulated on page 6 are subject to the followingreductions
5% when air inlet filters are fitted.3% for every 500 metres by which the operating altitudeexceeds 1000 metres above mean sea level.3% for every 5 C by which the operational ambienttemperature exceeds 40 C.
Note: Requirement for operating in an ambient exceeding60 C must be referred to the factory.
NB Continuous development of our products entitles us tochange specification details without notice, therefore theymust not be regarded as binding.
Front cover drawing typical of product range.
STANDARDS
Stamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of other internationalstandards such as BS5000, VDE 0530, NEMA MG1-32, IEC34,CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.
VOLTAGE REGULATORS
SX460 AVR - STANDARD
With this self excited control system the main stator suppliespower via the Automatic Voltage Regulator (AVR) to the exciterstator. The high efficiency semiconductors of the AVR ensurepositive build-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through a threephase full wave bridge rectifier. This rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit.
AS440 AVR
With this self-excited system the main stator provides power viathe AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial lowlevels of residual voltage.The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permit paralleloperation with other ac generators.
MX341 AVR
This sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the main exciter,giving a source of constant excitation power independent ofgenerator output. The main exciter output is then fed to themain rotor, through a full wave bridge, protected by a surgesuppressor. The AVR has in-built protection against sustainedover-excitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds.An engine relief load acceptance feature can enable full load tobe applied to the generator in a single step.If three-phase sensing is required with the PMG system theMX321 AVR must be used.We recommend three-phase sensing for applications withgreatly unbalanced or highly non-linear loads.
MX321 AVR
The most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally, three-phase rmssensing, for improved regulation and performance.Over voltage protection is built-in and short circuit current leveladjustments is an optional facility.
WINDINGS & ELECTRICAL PERFORMANCE
All generator stators are wound to 2/3 pitch. This eliminatestriplen (3rd, 9th, 15th …) harmonics on the voltage waveformand is found to be the optimum design for trouble-free supplyof non-linear loads. The 2/3 pitch design avoids excessiveneutral currents sometimes seen with higher winding pitches,when in parallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. This winding,with the 2/3 pitch and carefully selected pole and toothdesigns, ensures very low waveform distortion.
TERMINALS & TERMINAL BOX
Standard generators are 3-phase reconnectable with 12 endsbrought out to the terminals, which are mounted on a cover atthe non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It has removablepanels for easy access.
SHAFT & KEYS
All generator rotors are dynamically balanced to better thanBS6861:Part 1 Grade 2.5 for minimum vibration in operation.
INSULATION/IMPREGNATION
The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanical strengthrequired for rotating components.
QUALITY ASSURANCE
Generators are manufactured using production procedureshaving a quality assurance level to BS EN ISO 9001.
The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any change inperformance will fall within the limits of Criteria 'B' of EN61000-6-2:2001. At no time will the steady-state voltageregulation exceed 2%.
DE RATES
All values tabulated on page 6 are subject to the followingreductions
5% when air inlet filters are fitted.3% for every 500 metres by which the operating altitudeexceeds 1000 metres above mean sea level.3% for every 5 C by which the operational ambienttemperature exceeds 40 C.
Note: Requirement for operating in an ambient exceeding60 C must be referred to the factory.
NB Continuous development of our products entitles us tochange specification details without notice, therefore theymust not be regarded as binding.
Front cover drawing typical of product range.
2
APPRO
VED D
OC
UM
ENT
CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.
A.V.R. MX321 MX341
VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT
CONTROL SYSTEM SELF EXCITED
A.V.R. SX460 AS440
VOLTAGE REGULATION ± 1.5 % ± 1.0 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT
INSULATION SYSTEM CLASS H
PROTECTION
RATED POWER FACTOR
STATOR WINDING
WINDING PITCH
WINDING LEADS
STATOR WDG. RESISTANCE
ROTOR WDG. RESISTANCE
EXCITER STATOR RESISTANCE
EXCITER ROTOR RESISTANCE
R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others
WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%
MAXIMUM OVERSPEED
BEARING DRIVE END
BEARING NON-DRIVE END
UCI274FWINDING 17
REFER TO SHORT CIRCUIT DECREMENT CURVES (page 5)
BALL. 6310-2RS (ISO)
IP23
0.8
1.52 Ohms at 22°C
0.038 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED
TWO THIRDS
12
20 Ohms at 22°C
0.091 Ohms PER PHASE AT 22°C
DOUBLE LAYER CONCENTRIC
2250 Rev/Min
BALL. 6315-2RS (ISO)
WEIGHT COMP. GENERATORWEIGHT WOUND STATORWEIGHT WOUND ROTORWR² INERTIASHIPPING WEIGHTS in a cratePACKING CRATE SIZETELEPHONE INTERFERENCECOOLING AIRVOLTAGE SERIES STARVOLTAGE PARALLEL STARVOLTAGE SERIES DELTA kVA BASE RATING FOR REACTANCE VALUESXd DIR. AXIS SYNCHRONOUSX'd DIR. AXIS TRANSIENTX''d DIR. AXIS SUBTRANSIENTXq QUAD. AXIS REACTANCEX''q QUAD. AXIS SUBTRANSIENTXL LEAKAGE REACTANCEX2 NEGATIVE SEQUENCEX0 ZERO SEQUENCE
REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATEDT'd TRANSIENT TIME CONST. 0.035sT''d SUB-TRANSTIME CONST. 0.011sT'do O.C. FIELD TIME CONST. 0.9sTa ARMATURE TIME CONST. 0.009sSHORT CIRCUIT RATIO 1/Xd
346V
206.3
2.170.18
0.140.08
0.121.300.170.07
600V300V
0.617 m³/sec 1308 cfm
1 BEARING 2 BEARING
200 kg
577 kg 123 x 67 x 103(cm)
563 kg
545 kg
THF<2% TIF<50
177.71 kg
1.5044 kgm2
188.67 kg
1.555 kgm2
( )
530 kg
123 x 67 x 103(cm)
200 kg
33
APPRO
VED D
OC
UM
ENT
UCI274FWinding 17
Locked Rotor Motor Starting CurvesSX
600V600V600V600V600V
0
5
10
15
20
25
30
0 100 200 300 400 500 600LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
SX
MX
600V600V600V600V600V
0
5
10
15
20
25
30
0 100 200 300 400 500 600LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
600V600V600V600V600V
0
5
10
15
20
25
30
0 100 200 300 400 500 600 700 800LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
44
APPRO
VED D
OC
UM
ENT
UCI274FWinding 17
Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed
THREE PHASE EFFICIENCY CURVES
Based on star (wye) connection.
1000
10000
)
SYMMETRICAL
ASYMMETRICAL
3-phase 2-phase L-L 1-phase L-Nx 1.00 x 0.87 x 1.30x 1.00 x 1.80 x 3.20x 1.00 x 1.50 x 2.5010 sec. 5 sec. 2 sec.
SustainedMax. sustained duration
All other times are unchanged
InstantaneousMinimum
Sustained Short Circuit = 700 Amps
NoteThe following multiplication factor should be used to convert the values from curve for thevarious types of short circuit :
10
100
1000
10000
0.001 0.01 0.1 1 10TIME (secs)
CU
RR
ENT
(Am
ps)
SYMMETRICAL
ASYMMETRICAL
55
APPRO
VED D
OC
UM
ENT
Class - Temp Rise
Series Star (V)Parallel Star (V)Series Delta (V)
kVA
kW
Efficiency (%)
kW Input 183.6
346
218.8
175.0
92.5
189.2
346
212.5
170.0
92.6
150.0
92.9
161.4
346
206.3
165.0
92.7
178.1
DIMENSIONS
UCI274F
Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C
Winding 17 / 0.8 Power Factor
RATINGS
346
187.5
600300
600300
600300
600300
60Hz60Hz
66
APPRO
VED D
OC
UM
ENT
UCI274F-17-TD-EN-SG-A
Head Office Address:Barnack Road, StamfordLincolnshire, PE9 2NB
United KingdomTel: +44 (0) 1780 484000Fax: +44 (0) 1780 484100
www.cumminsgeneratortechnologies.com
Copyright 2010, Cummins Generator Technologies Ltd, All Rights ReservedStamford and AvK are registered trade marks of Cummins Generator Technologies Ltd
Cummins and the Cummins logo are registered trade marks of Cummins Inc.
UCI274F-17-TD-EN-SG-A
Head Office Address:Barnack Road, StamfordLincolnshire, PE9 2NB
United KingdomTel: +44 (0) 1780 484000Fax: +44 (0) 1780 484100
www.cumminsgeneratortechnologies.com
Copyright 2010, Cummins Generator Technologies Ltd, All Rights ReservedStamford and AvK are registered trade marks of Cummins Generator Technologies Ltd
Cummins and the Cummins logo are registered trade marks of Cummins Inc.
DSE7410/20AUTO START & AUTO MAINS FAILURE MODULES
DSEGenset
®
11ph2ph3phN
1ph2ph3phEN
1ph2ph3phN
1
11
232
6 4
MODEM
ISSUE 1
RS232 ANDRS485
CONFIGURABLEINPUTS
DC OUTPUTS ANALOGUESENDERS
EMERGENCY STOP
DC POWER SUPPLY 8-35V
DEUTZISUZUPERKINSCATERPILLARMTUVOLVOCUMMINSSCANIA
+D +W/L
GENERATOR SENSING
VOLTSVOLTS CURRENT
ELECTRONICENGINES &MAGNETIC PICK-UP
FUEL & CRANKOUTPUTSFLEXIBLE WITH CAN
CHARGEALTERNATOR
N/O VOLTFREE OUTPUT
N/C VOLT FREEOUTPUT
+
COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OFGEN-SET APPLICATIONS
7
OTHER
DSE7410/20
The DSE7410 is an Auto StartControl Module and the DSE7420is an Auto Mains (Utility) FailureControl Module suitable for a widevariety of single, diesel or gas, gen-set applications.
A sophisticated module monitoringan extensive number of engineparameters, the DSE74xx willannunciate warnings, shutdownand engine status information onthe back-lit LCD screen, illuminatedLED, remote PC, audible alarm andvia SMS text alerts. The moduleincludes RS232, RS485 & Ethernetports as well as dedicatedterminals for system expansion.
The DSE7400 Series modules arecompatible with electronic (CAN)and non-electronic (magnetic pick-up/alternator sensing) engines andoffer a comprehensive number offlexible inputs, outputs andextensive engine protections so thesystem can be easily adapted tomeet the most demanding industryparalleling requirements.
The modules can be easilyconfigured using the DSEConfiguration Suite Software.Selected front panel editing is alsoavailable.
FEATURES
ENVIRONMENTAL TESTING STANDARDS
ELECTRO-MAGNETIC COMPATIBILITYBS EN 61000-6-2EMC Generic Immunity Standard for the Industrial EnvironmentBS EN 61000-6-4EMC Generic Emission Standard for the Industrial Environment
ELECTRICAL SAFETYBS EN 60950Safety of Information Technology Equipment, including Electrical Business Equipment
TEMPERATUREBS EN 60068-2-1Ab/Ae Cold Test -30 oCBS EN 60068-2-2Bb/Be Dry Heat +70 oC
VIBRATIONBS EN 60068-2-6Ten sweeps in each of three major axes5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn
HUMIDITYBS EN 60068-2-30Db Damp Heat Cyclic 20/55 oC@ 95% RH 48 HoursBS EN 60068-2-78Cab Damp Heat Static 40 oC@ 93% RH 48 Hours
SHOCKBS EN 60068-2-27Three shocks in each of three major axes15 gn in 11 mS
DEGREES OF PROTECTIONPROVIDED BY ENCLOSURESBS EN 60529IP65 - Front of module when installed into thecontrol panel with the supplied sealing gasket.
DSE2130DSE2131DSE2133DSE2152DSE2157DSE2548 485
MODBUS
USBPORT
USBHOST
ETHERNET
PC
DSENETEXPANSION
MAINS (UTILITY) SENSING (DSE7420)BUS SENSING (DSE7410)
DEEP SEA ELECTRONICS PLC UKHighfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PHTELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303EMAIL [email protected] WEBSITE www.deepseaplc.com
DEEP SEA ELECTRONICS INC USA3230 Williams Avenue, Rockford, IL 61101-2668 USATELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708EMAIL [email protected] WEBSITE www.deepseausa.com
055-108/01/12 (1)
KEY FEATURES• Configurable inputs (11)• Configurable outputs (8)• Voltage measurement• Mains (utility) failure detection• Dedicated load test button• kW overload alarms• Comprehensive electrical
protection• RS232, RS485 & Ethernet
remote communications• Modbus RTU/TCP • PLC functionality• Multi event exercise timer • Back-lit LCD 4-line text display• Multiple display languages• Automatic start/Manual start• Audible alarm• Fixed and flexible LED indicators • Event log (250)• Engine protection• Fault condition notification to
a designated PC• Front panel mounting• Protected front panel
programming• Configurable alarms and timers• Configurable start and stop timers
• Five key menu navigation• Front panel editing with PIN
protection• 3 configurable maintenance
alarms• CAN and magnetic pick-up/Alt.
sensing• Fuel usage monitor and low fuel
alarms• Charge alternator failure alarm• Manual speed control (on
compatible CAN engines)• Manual fuel pump control • “Protections disabled” feature• Reverse power protection• Power monitoring (kW h, kV Ar,
kV A h, kV Ar h)• Load switching (load shedding
and dummy load outputs)• Automatic load transfer (DSE7420)• Unbalanced load protection• Independent earth fault trip• Fully configurable via DSE
Configuration Suite PC software• Configurable display languages• Remote SCADA monitoring via
DSE Configuration Suite PCsoftware
• Advanced SMS messaging(additional external modemrequired)
• Start & stop capability via SMSmessaging
• Additional display screens tohelp with modem diagnostics
• DSENet® expansion • Integral PLC editor
KEY BENEFITS• RS232, RS485 & Ethernet can
be used at the same time• DSENet® connection for
system expansion• PLC functionality• Five step dummy load support• Five step load shedding support• High number of inputs and
outputs• Worldwide language support• Direct USB connection to PC• Ethernet monitoring• USB host• Data logging & trending
RELATED MATERIALSTITLE PART NO’SDSE7410 Installation Instructions 053-085DSE7420 Installation Instructions 053-088DSE74xx Quick Start Guide 057-162DSE74xx Operator Manual 057-161DSE74xx PC Configuration Suite Manual 057-160
SPECIFICATION
DC SUPPLYCONTINUOUS VOLTAGE RATING8 V to 35 V Continuous
CRANKING DROPOUTSAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropoutand supply recovers to 5 V. This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT260 mA at 12 V, 130 mA at 24 V
MAXIMUM STANDBY CURRENT120 mA at 12 V, 65 mA at 24 V
CHARGE FAIL/EXCITATION RANGE0 V to 35 V
OUTPUTSOUTPUT A (FUEL)15 A DC at supply voltage
OUTPUT B (START)15 A DC at supply voltage
OUTPUTS C & D8 A AC at 250 V AC (Volt free)
AUXILIARY OUTPUTS E,F,G,H,I & J2 A DC at supply voltage
GENERATOR VOLTAGE RANGE 15 V to 333 V AC (L-N)
FREQUENCY RANGE3.5 Hz to 75 Hz
MAINS (UTILITY) (DSE7420)VOLTAGE RANGE 15 V to 333 V AC (L-N)
FREQUENCY RANGE3.5 Hz to 75 Hz
BUS (DSE7410)VOLTAGE RANGE 15 V to 333 V AC (L-N)
FREQUENCY RANGE3.5 Hz to 75 Hz
MAGNETIC PICK UPVOLTAGE RANGE+/- 0.5 V to 70 V
FREQUENCY RANGE10,000 Hz (max)
DIMENSIONSOVERALL240 mm x 172 mm x 57 mm 9.4” x 6.8” x 2.2”
PANEL CUTOUT 220 mm x 160 mm 8.7” x 6.3”
MAXIMUM PANEL THICKNESS8 mm0.3”
STORAGE TEMPERATURE RANGE-40 oC to +85 oC
DSE7410/20AUTO START & AUTO MAINS FAILURE MODULES
®
DSEGenset
FEATURES
Registered in England & Wales No.01319649VAT No.316923457
Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to changethe details shown on this data sheet without prior notice. The contents are intended for guidance only.
DSE7410
DSE7420
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG23G0200TFFJNNNNNN
PRODUCT VIEW (Use Mouse to Rotate and Zoom)
Tech Data for Configured Product
Power Defense Catalog Number PDG23G0200TFFJNNNNNNFrame Size Frame 2Poles 3 PoleVoltage 480V ACInterruption or Breaking Capacity ( Icu/Ics) 35kAContinuous Current Rating (In) 200ATrip Unit Type TM Trip UnitTrip Unit Options 1 FixedTrip Unit Options 2 FixedIndicating Accessories NoneIndicating Accessories Terminal NoneTripping Accessories NoneTripping Accessory Terminal NoneTripping Accessory Voltage NoneLine Type Description Option 1 - Standard TerminalLine Conductor Options (1) 4 - 4/0Line Terminal Type AluminumLoad Type Description Option 1 - Standard TerminalLoad Conductor Options (1) 4 - 4/0Load Terminal Type AluminumSpecial Options - Type of Modification NoneDetails NoneAdditional Description None
PDF Datasheet Powered by CADENAS PARTsolutions
Eaton’s Power Defense™ molded case circuit breakers, a globally rated platform designed to help keep your power system safe with latest protection technology. Engineered for the future: IoT and Industry 4.0 features such as built-in communications, advanced energy metering, and algorithms that signal breaker maintenance; zone selective interlock technology that clears faults quickly and locally; ArcFlash reduction options that help protect your people, and not to mention Eaton’s best-inclass support and service.
Datasheet creation date: 13/11/2019 22:35
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG23G0200TFFJNNNNNN
PDF Datasheet Powered by CADENAS PARTsolutions
Technical drawings
Datasheet creation date: 13/11/2019 22:35
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG23G0200TFFJNNNNNN
PDF Datasheet Powered by CADENAS PARTsolutions
Datasheet creation date: 13/11/2019 22:35
General Technical Data
Frame Rating (In) 200AReference Standard UL489, CSA 22.2, IEC 60947-2 & GBNumber of poles 3Neutral rating -Interruption Rating Designator F / G / K / M / N / PUL Interruption Rating to UL 489 (240Vac) 35 / 65 / 85 / 100 / 150 / 200kAUL Interruption Rating to UL 489 (480Vac) 25 / 35 / 50 / 65(a) / 85 / 100kAUL Interruption Rating to UL 489 (600Vac) 14 / 18 / 22 / 25 / 30 / 35kAUL Interruption Rating to UL 489 (125/250Vdc) 10 / 10 / 10 / 22 / 22 / 22kAUL Current Limiting N / N / Y / Y / Y / YRated breaking capacity to IEC 60947-2 (220-240 Vac lcu) 35 / 55 / 85 / 100 / 150 / 200kARated breaking capacity to IEC 60947-2 (220-240 Vac lcs) 35 / 55 / 85 / 100 / 100 / 150kARated breaking capacity to IEC 60947-2 (380-415 Vac lcu) 25 / 36 / 50 / 70 / 70 / 100kARated breaking capacity to IEC 60947-2 (380-415 Vac lcs) 25 / 36 / 50 / 53 / 70 / 70kARated breaking capacity to IEC 60947-2 (440 Vac lcu) 25 / 30 / 35 / 50 / 70 / 100kARated breaking capacity to IEC 60947-2 (440 Vac lcs) 20 / 22.5 / 35 / 40 / 50 / 65kARated breaking capacity to IEC 60947-2 (525 Vac lcu)Rated breaking capacity to IEC 60947-2 (525 Vac lcs) 15 / 15 / 15 / 15 / 15 / 18kARated breaking capacity to IEC 60947-2 (690 Vac lcu) - / 8 / 10 / 10 / 10 / 10kARated breaking capacity to IEC 60947-2 (690 Vac lcs) - / 4 / 5 / 5 / 5 / 5kARated breaking capacity to IEC 60947-2 (125V DC lcu) 10 / 10 / 10 / 22 / 22 / 22kARated breaking capacity to IEC 60947-2 (250V DC 2P in series lcs) 10 / 10 / 10 / 22 / 22 / 22kAFrequency 50/60HzTrip Unit Type TM Trip UnitContinuous Current Range Fixed100% UL489 RatedInstantaneous/Short Circuit Range FixedMagnetic/Instantaneous Override 2000ADimensions H x W x D (inches) 6 x 4.12 x 3.50Pole to pole distance inches 1,375Approx Weight lbs 4RoHS Compliance YesUL File Number E7819Ambient Temp CalibrationDerating at 50CDerating at 60C 95%Derating at 70C 90%
1. 480Vac corresponds to 277Vac for 1P 2. 600Vac corresponds to 347Vac for 1P
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0250B2NJNNNNNN
PRODUCT VIEW (Use Mouse to Rotate and Zoom)
Tech Data for Configured Product
Power Defense Catalog Number PDG33G0250B2NJNNNNNNFrame Size Frame 3Poles 3 PoleVoltage 480V ACInterruption or Breaking Capacity ( Icu/Ics) 35kAContinuous Current Rating (In) 250ATrip Unit Type PXR10Trip Unit Options 1 LSITrip Unit Options 2 NoneIndicating Accessories NoneIndicating Accessories Terminal NoneTripping Accessories NoneTripping Accessory Terminal NoneTripping Accessory Voltage NoneLine Type Description Option 1 - Standard TerminalLine Conductor Options (1) 250 - 500Line Terminal Type AluminumLoad Type Description Option 1 - Standard TerminalLoad Conductor Options (1) 250 - 500Load Terminal Type AluminumSpecial Options - Type of Modification NoneDetails NoneAdditional Description None
PDF Datasheet Powered by CADENAS PARTsolutions
Eaton’s Power Defense™ molded case circuit breakers, a globally rated platform designed to help keep your power system safe with latest protection technology. Engineered for the future: IoT and Industry 4.0 features such as built-in communications, advanced energy metering, and algorithms that signal breaker maintenance; zone selective interlock technology that clears faults quickly and locally; ArcFlash reduction options that help protect your people, and not to mention Eaton’s best-inclass support and service.
Datasheet creation date: 02/12/2019 17:27
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0250B2NJNNNNNN
PDF Datasheet Powered by CADENAS PARTsolutions
Technical drawings
Datasheet creation date: 02/12/2019 17:27
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0250B2NJNNNNNN
PDF Datasheet Powered by CADENAS PARTsolutions
Datasheet creation date: 02/12/2019 17:27
General Technical Data
Frame Rating (In) 250AReference Standard UL489, CSA 22.2, IEC 60947-2 & GBNumber of poles 3Neutral rating -Interruption Rating Designator F / G / K / M / N / PUL Interruption Rating to UL 489 (240Vac) 35 / 65 / 85 / 100 / 150 / 200kAUL Interruption Rating to UL 489 (480Vac) 25 / 35 / 50 / 65(a) / 85 / 100kAUL Interruption Rating to UL 489 (600Vac) 14 / 18 / 25 / 35 / 50 / 65kAUL Interruption Rating to UL 489 (125/250Vdc)UL Current Limiting N / N / N / Y / Y / YRated breaking capacity to IEC 60947-2 (220-240 Vac lcu) 35 / 55 / 85 / 100 / 150 / 200kARated breaking capacity to IEC 60947-2 (220-240 Vac lcs) 35 / 55 / 85 / 100 / 100 / 150kARated breaking capacity to IEC 60947-2 (380-415 Vac lcu) 25 / 36 / 50 / 70 / 70 / 100kARated breaking capacity to IEC 60947-2 (380-415 Vac lcs) 25 / 36 / 50 / 53 / 70 / 70kARated breaking capacity to IEC 60947-2 (440 Vac lcu) 25 / 30 / 35 / 50 / 70 / 100kARated breaking capacity to IEC 60947-2 (440 Vac lcs) 20 / 22.5 / 35 / 40 / 50 / 50kARated breaking capacity to IEC 60947-2 (525 Vac lcu) 18 / 20 / 25 / 30 / 35 / 40kARated breaking capacity to IEC 60947-2 (525 Vac lcs) 5 / 7.5 / 10 / 15 / 25 / 25kARated breaking capacity to IEC 60947-2 (690 Vac lcu) - / 8 / 10 / 15 / 20 / 20kARated breaking capacity to IEC 60947-2 (690 Vac lcs) - / 4 / 5 /7. 5 / 10 / 10kARated breaking capacity to IEC 60947-2 (125V DC lcu)Rated breaking capacity to IEC 60947-2 (250V DC 2P in series lcs) 10 / 10 / 10 / 22 / 22 / 22kAFrequency 50/60HzTrip Unit Type PXR10Continuous Current Range 90 - 250A100% UL489 Rated YesInstantaneous/Short Circuit Range 2 - 15 InMagnetic/Instantaneous Override 4400ADimensions H x W x D (inches) 10.125 x 5.47 x 4.297Pole to pole distance inches 1,719Approx Weight lbs 16RoHS Compliance YesUL File Number E7819Ambient Temp CalibrationDerating at 50CDerating at 60CDerating at 70C
1. 480Vac corresponds to 277Vac for 1P 2. 600Vac corresponds to 347Vac for 1P
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0600B2NJNNNNNN
PRODUCT VIEW (Use Mouse to Rotate and Zoom)
Tech Data for Configured Product
Power Defense Catalog Number PDG33G0600B2NJNNNNNNFrame Size Frame 3Poles 3 PoleVoltage 480V ACInterruption or Breaking Capacity ( Icu/Ics) 35kAContinuous Current Rating (In) 600ATrip Unit Type PXR10Trip Unit Options 1 LSITrip Unit Options 2 NoneIndicating Accessories NoneIndicating Accessories Terminal NoneTripping Accessories NoneTripping Accessory Terminal NoneTripping Accessory Voltage NoneLine Type Description Option 1 - Standard TerminalLine Conductor Options (2) 2 - 500Line Terminal Type AluminumLoad Type Description Option 1 - Standard TerminalLoad Conductor Options (2) 2 - 500Load Terminal Type AluminumSpecial Options - Type of Modification NoneDetails NoneAdditional Description None
PDF Datasheet Powered by CADENAS PARTsolutions
Eaton’s Power Defense™ molded case circuit breakers, a globally rated platform designed to help keep your power system safe with latest protection technology. Engineered for the future: IoT and Industry 4.0 features such as built-in communications, advanced energy metering, and algorithms that signal breaker maintenance; zone selective interlock technology that clears faults quickly and locally; ArcFlash reduction options that help protect your people, and not to mention Eaton’s best-inclass support and service.
Datasheet creation date: 02/12/2019 17:40
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0600B2NJNNNNNN
PDF Datasheet Powered by CADENAS PARTsolutions
Technical drawings
Datasheet creation date: 02/12/2019 17:40
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0600B2NJNNNNNN
PDF Datasheet Powered by CADENAS PARTsolutions
Datasheet creation date: 02/12/2019 17:40
General Technical Data
Frame Rating (In) 600AReference Standard UL489, CSA 22.2, IEC 60947-2 & GBNumber of poles 3Neutral rating -Interruption Rating Designator F / G / K / M / N / PUL Interruption Rating to UL 489 (240Vac) 35 / 65 / 85 / 100 / 150 / 200kAUL Interruption Rating to UL 489 (480Vac) 25 / 35 / 50 / 65(a) / 85 / 100kAUL Interruption Rating to UL 489 (600Vac) 14 / 18 / 25 / 35 / 50 / 65kAUL Interruption Rating to UL 489 (125/250Vdc)UL Current Limiting N / N / N / N / Y / YRated breaking capacity to IEC 60947-2 (220-240 Vac lcu) 35 / 55 / 85 / 100 / 150 / 200kARated breaking capacity to IEC 60947-2 (220-240 Vac lcs) 35 / 55 / 85 / 100 / 100 / 150kARated breaking capacity to IEC 60947-2 (380-415 Vac lcu) 25 / 36 / 50 / 70 / 70 / 100kARated breaking capacity to IEC 60947-2 (380-415 Vac lcs) 25 / 36 / 50 / 53 / 70 / 70kARated breaking capacity to IEC 60947-2 (440 Vac lcu) 25 / 30 / 35 / 50 / 70 / 100kARated breaking capacity to IEC 60947-2 (440 Vac lcs) 20 / 22.5 / 35 / 40 / 50 / 50kARated breaking capacity to IEC 60947-2 (525 Vac lcu) 18 / 20 / 25 / 30 / 35 / 40kARated breaking capacity to IEC 60947-2 (525 Vac lcs) 5 / 7.5 / 10 / 15 / 25 / 25kARated breaking capacity to IEC 60947-2 (690 Vac lcu) - / 8 / 10 / 15 / 20 / 20kARated breaking capacity to IEC 60947-2 (690 Vac lcs) - / 4 / 5 /7. 5 / 10 / 10kARated breaking capacity to IEC 60947-2 (125V DC lcu)Rated breaking capacity to IEC 60947-2 (250V DC 2P in series lcs) 10 / 10 / 10 / 22 / 22 / 22kAFrequency 50/60HzTrip Unit Type PXR10Continuous Current Range 250 - 600A100% UL489 Rated YesInstantaneous/Short Circuit Range 2 - 10 InMagnetic/Instantaneous Override 7200ADimensions H x W x D (inches) 10.125 x 5.47 x 4.297Pole to pole distance inches 1,719Approx Weight lbs 16RoHS Compliance YesUL File Number E7819Ambient Temp CalibrationDerating at 50CDerating at 60CDerating at 70C
1. 480Vac corresponds to 277Vac for 1P 2. 600Vac corresponds to 347Vac for 1P
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG43G0800B2NJNNNNNN
PRODUCT VIEW (Use Mouse to Rotate and Zoom)
Tech Data for Configured Product
Power Defense Catalog Number PDG43G0800B2NJNNNNNNFrame Size Frame 4Poles 3 PoleVoltage 240V ACInterruption or Breaking Capacity ( Icu/Ics) 55kAContinuous Current Rating (In) 800ATrip Unit Type PXR10Trip Unit Options 1 LSITrip Unit Options 2 NoneIndicating Accessories NoneIndicating Accessories Terminal NoneTripping Accessories NoneTripping Accessory Terminal NoneTripping Accessory Voltage NoneLine Type Description Option 1 - Standard TerminalLine Conductor Options (3) 3/0 - 400Line Terminal Type AluminumLoad Type Description Option 1 - Standard TerminalLoad Conductor Options (3) 3/0 - 400Load Terminal Type AluminumSpecial Options - Type of Modification NoneDetails NoneAdditional Description None
PDF Datasheet Powered by CADENAS PARTsolutions
Eaton’s Power Defense™ molded case circuit breakers, a globally rated platform designed to help keep your power system safe with latest protection technology. Engineered for the future: IoT and Industry 4.0 features such as built-in communications, advanced energy metering, and algorithms that signal breaker maintenance; zone selective interlock technology that clears faults quickly and locally; ArcFlash reduction options that help protect your people, and not to mention Eaton’s best-inclass support and service.
Datasheet creation date: 20/11/2019 22:02
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG43G0800B2NJNNNNNN
PDF Datasheet Powered by CADENAS PARTsolutions
Technical drawings
Datasheet creation date: 20/11/2019 22:02
Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG43G0800B2NJNNNNNN
PDF Datasheet Powered by CADENAS PARTsolutions
Datasheet creation date: 20/11/2019 22:02
General Technical Data
Frame Rating (In) 800AReference Standard UL489, CSA 22.2, IEC 60947-2 & GBNumber of poles 3Neutral rating -Interruption Rating Designator G / K / MUL Interruption Rating to UL 489 (240Vac) 65 / 85 / 100kAUL Interruption Rating to UL 489 (480Vac) 35 / 50 / 65(a)kAUL Interruption Rating to UL 489 (600Vac) 18 / 25 / 35kAUL Interruption Rating to UL 489 (125/250Vdc)UL Current Limiting -Rated breaking capacity to IEC 60947-2 (220-240 Vac lcu) 55 / 85 / 100 / 100kARated breaking capacity to IEC 60947-2 (220-240 Vac lcs) 55 / 85 / 100 / 100kARated breaking capacity to IEC 60947-2 (380-415 Vac lcu) 36 / 50 / 70 / 70kARated breaking capacity to IEC 60947-2 (380-415 Vac lcs) 36 / 50 / 53 / 70kARated breaking capacity to IEC 60947-2 (440 Vac lcu) 30 / 35 / 50 / 65kARated breaking capacity to IEC 60947-2 (440 Vac lcs) 22.5 / 35 / 40 / 50kARated breaking capacity to IEC 60947-2 (525 Vac lcu) 20 / 25 / 30 / 35kARated breaking capacity to IEC 60947-2 (525 Vac lcs) 16.5 / 20 / 25 / 25kARated breaking capacity to IEC 60947-2 (690 Vac lcu) 8 / 10 / 15 / 20kARated breaking capacity to IEC 60947-2 (690 Vac lcs) 4 / 5 /7. 5 / 10kARated breaking capacity to IEC 60947-2 (125V DC lcu)Rated breaking capacity to IEC 60947-2 (250V DC 2P in series lcs) 22 / 22 / 25kAFrequency 50/60HzTrip Unit Type PXR10Continuous Current Range 320 - 800A100% UL489 Rated YesInstantaneous/Short Circuit Range 2 - 8 InMagnetic/Instantaneous Override 6800ADimensions H x W x D (inches) 16 x 8.25 x 4.38Pole to pole distance inches 2,75Approx Weight lbs 29,98RoHS Compliance YesUL File Number E7819Ambient Temp CalibrationDerating at 50CDerating at 60CDerating at 70C
1. 480Vac corresponds to 277Vac for 1P 2. 600Vac corresponds to 347Vac for 1P
Phone: 800-767-8541 • Fax: 707-226-9670 • www.guestindustrial.com12
Genset Chargers
2
5
6
10
1
1
1
2
2
5
6
5/5
12V
24V
12V
12V+12V
100 - 13050/60Hz
100 - 13050/60Hz
100 - 13050/60Hz
100 - 13050/60Hz
6' w/ Connect-
Charge plug
6' SJT 18-3w/ Connect- Charge plug
6' cable w/molded plugrated -40 to 105C
Studs
4' w/ ring terminals
6' SJT 18-3w/ ring
terminals
4' w/ ring terminals
rated -40 to 105C
Studs
2.9" x 5.1" x 1.5"
7.4" x 6.3" x 2.4"
3.5" x 6.4" x 2.3"
5.5" x 7.8" x 2.4"
UL
UL
UL
–
UL
2
4.5
4
5.6
2602A-12
2602A-12-B (bulk)
2605A-1-24RT-01(bulk pack only) (1)
2608A-B-01 (bulk pack only) (1)
2610A
2610A-B (bulk)
MODEL TOTALAMPS
OUT-PUTS
AMPS PEROUTPUT
BATTERYSYSTEM
INPUTVOLTAGE AC DC DIMENSIONS AGENCY
LISTINGWT.
(LBS)
(bulk only)
Genset Chargers
Guest chargers are proven performers in genset applications.For specific application information, or if you are developing a newproduct, be sure to consult with the Guest applications engineeringteam to ensure the correct charger is specified.
2602A-12
2610A
2608A-B-01
Individual agency listings as shown in product chart.(1) 2-stage charging
14
BERGARI
SOLUTIO
NS
mem
ber of the m
and
ersgroup
09/15/2017O
VERA
LL HEIG
HT C
HA
NG
EC
B
INFO
RMA
TION
±1°
.XXXX = ±0.03125.XXX = ±0.0625.XX = ±0.125.X = ±0.25
ALL A
NG
LESO
THERWISE SPEC
IFIED
ENGINEERING
DRAW
N BY
CHEC
KED BY
MA
NUFAC
TURING
02
TOLERA
NC
ES DO
NO
T APPLY TO
TOLERA
NC
ES UNLESS
REVEC
OD
ESCRIPTIO
NC
OM
MERC
IAL FEA
TURES
permission from
Bergari Solutions, LLC.
DESCRIPTIO
N
DATE
DATE
DATE
GA
GE TH
ICKN
ESS OR
copied or shared in any form w
ithout the express
DATE
ENG
INE
INFO
RMA
TION
RESON
ATO
R ALPHA
SILENC
ER Km
ENG
INE M
AKE
ENG
INE M
ODEL
DISPLAC
EMEN
T
EXHAUST FLO
W
EXHAUST TEM
PERATURE
MA
X BAC
K PRESSURE
RAW
SOUN
D PRESSURE
CO
NSTRUC
TION
MA
TERIAL
FINISH
PART N
UMBER
WEIG
HT (LBS)59
SHEET SIZE
THIRD A
NG
LE PROJEC
TION
RESON
ATO
R FREQUEN
CY
SCA
LE (DO N
OT SC
ALE)
A
1
BCD
23
45
67
8
PSI
5.7L
537
1063
1300
---
---------
1:7B
CS
HIG
H TEM
P BLAC
K PAIN
T
500-00834602
CB
3.50-3.50 Ø14.00
SIL: CO
MP C
RIT CS S-E
CB
CB
CB
09/15/2017
CUSTO
MER
CUSTO
MER P/N
------
SILENC
ER IL
SHEET3 OF 3
---
40
26.00 OA
L F:5.50 ---
07/13/2017
REV.
BYD
ATE
This drawing and the inform
ation contained is confidential and the property of Bergari
Solutions, LLC. N
one of this information is to be
SILENC
ER
---
12.00
3.50 OD
10.00
19.07
3.63 OD
SLOTTED
CUFF
10.00
14.00N
OM
0.50-14.00 NPT D
RAIN
5.50
20.50
26.00 22.00
3.00TYP
D
TYPTYP
4.00
3.00
8.00
3.00
11.00
DETA
IL DSC
ALE 2 : 7
0.75
TYP TYP
0.50TYP
1.05
1.00TYP