49
Gillette Generators, Inc. 2921 Thorne Dr. Elkhart, IN 46514 Ph: 574-264-9639 Fax: 574-262-1840 Web: www.gillettegenerators.com spc4-190719 1 60 HZ MODEL SPJD-1550 LIQUID COOLED DIESEL ENGINE GENERATOR SET GENERATOR RATINGS GENERATOR MODEL VOLTAGE PH HZ 120°C RISE STANDBY RATING POWER LEAD CONNECTIONS L-N L-L KW/KVA AMP SPJD-1550-1-1 120 240 1 60 155/155 646 4 LEAD DEDICATED 1 PH SPJD-1550-3-2 120 208 3 60 151/188.8 525 12 LEAD LOW WYE SPJD-1550-3-3 120 240 3 60 151/188.8 455 12 LEAD HIGH DELTA SPJD-1550-3-4 277 480 3 60 155/193.8 233 12 LEAD HIGH WYE SPJD-1550-3-5 127 220 3 60 151/188.8 496 12 LEAD LOW WYE SPJD-1550-3-16 346 600 3 60 155/193.8 186 4 LEAD DEDICATED 3 PH RATINGS: All single phase gen-sets are dedicated 4 lead windings, rated at unity (1.0) power factor. All three phase gen-sets are 12 lead windings, rated at .8 power factor. 120° C “STANDBY RATINGS” are strictly for gen-sets that are used for back-up emergency power to a failed normal utility power source. This standby rating allows varying loads, with no overload capability, for the entire duration of utility power outage. All gen-set power ratings are based on temperature rise measured by resistance method as defined by MIL-STD 705C and IEEE STD 115, METHOD 6.4.4. All generators have class H (180°C) insulation system on both rotor and stator windings. All factory tests and KW/KVA charts shown above are based 120°C (standby) R/R winding temperature, within a maximum 40°C ambient condition. Generators operated at standby power ratings must not exceed the temperature rise limitation for class H insulation system, as specified in NEMA MG1-22.40. Specifications & ratings are subject to change without prior notice. Model STANDBY 120ºC RISE HZ SPJD-1550-60 HERTZ 60 151/155 “OPEN” GEN-SET There is no enclosure, so gen-set must be placed within a weather protected area, un- inhabited by humans or animals, with proper ventilation. Silencer not supplied, as installation requirements are not known. However, this item is available as optional equipment. “LEVEL 2” HOUSED GEN-SET Full aluminum weather protection and superior sound attenuation for specific low noise applications. Critical grade muffler is standard. All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested. UL2200, UL1446, UL508, UL142, UL498 NFPA 110, 99, 70, 37 All generator sets meet NFPA-110 Level 1, when equipped with the necessary accessories and installed per NFPA standards. NEC 700, 701, 702, 708 NEMA ICS10, MG1, ICS6, AB1 ANSI C62.41, 27, 59, 32, 480, 40Q, 81U, 360-05 ASCE 7-05 & 7-10 All generator sets meet 180 MPH rating. EPA 40CFR Part 60, 1048, 1054, 1065, 1068

60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Gillette Generators, Inc. •••• 2921 Thorne Dr. •Elkhart, IN • 46514 • Ph: 574-264-9639 • Fax: 574-262-1840 • Web: www.gillettegenerators.com • spc4-190719 1

60 HZ MODEL

SPJD-1550 LIQUID COOLED DIESEL ENGINE GENERATOR SET

GENERATOR RATINGS

GENERATOR

MODEL

VOLTAGE PH HZ

120°°°°C RISE STANDBY RATING POWER LEAD

CONNECTIONS L-N L-L KW/KVA AMP

SPJD-1550-1-1 120 240 1 60 155/155 646 4 LEAD DEDICATED 1 PH

SPJD-1550-3-2 120 208 3 60 151/188.8 525 12 LEAD LOW WYE

SPJD-1550-3-3 120 240 3 60 151/188.8 455 12 LEAD HIGH DELTA

SPJD-1550-3-4 277 480 3 60 155/193.8 233 12 LEAD HIGH WYE

SPJD-1550-3-5 127 220 3 60 151/188.8 496 12 LEAD LOW WYE

SPJD-1550-3-16 346 600 3 60 155/193.8 186 4 LEAD DEDICATED 3 PH

RATINGS: All single phase gen-sets are dedicated 4 lead windings, rated at unity (1.0) power factor. All three phase gen-sets are 12 lead windings, rated at .8 power factor. 120° C “STANDBY RATINGS” are strictly for gen-sets that are used for back-up emergency power to a failed normal utility power source. This standby rating allows varying loads, with no overload capability, for the entire duration of utility power outage. All gen-set power ratings are based on temperature rise measured by resistance method as defined by MIL-STD 705C and IEEE STD 115, METHOD 6.4.4. All generators have class H (180°C) insulation system on both rotor and stator windings. All factory tests and KW/KVA charts shown above are based 120°C (standby) R/R winding temperature, within a maximum 40°C ambient condition. Generators operated at standby power ratings must not exceed the temperature rise limitation for class H insulation system, as specified in NEMA MG1-22.40. Specifications & ratings are subject to change without prior notice.

Model STANDBY

120ºC RISE HZ

SPJD-1550-60 HERTZ 60 151/155

“OPEN” GEN-SET

There is no enclosure, so gen-set must be placed within a weather protected area, un-inhabited by humans or animals, with proper ventilation. Silencer not supplied, as installation requirements are not known. However, this item is available as optional equipment.

“LEVEL 2” HOUSED GEN-SET

Full aluminum weather protection and superior sound attenuation for specific low noise applications. Critical grade muffler is standard.

All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested.

UL2200, UL1446, UL508, UL142, UL498

NFPA 110, 99, 70, 37 All generator sets meet NFPA-110 Level 1, when equipped with the necessary accessories and installed per NFPA standards.

NEC 700, 701, 702, 708 NEMA ICS10, MG1, ICS6, AB1 ANSI C62.41, 27, 59, 32, 480, 40Q, 81U, 360-05 ASCE 7-05 & 7-10

All generator sets meet 180 MPH rating. EPA 40CFR Part 60, 1048, 1054, 1065, 1068

Page 2: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Gillette Generators, Inc. •••• 2921 Thorne Dr. •Elkhart, IN • 46514 • Ph: 574-264-9639 • Fax: 574-262-1840 • Web: www.gillettegenerators.com • spc4-190719 2

GENERATOR SPECIFICATIONS

Manufacturer ................................... Stamford Electric Generators Model & Type ........... UCI274H-06, 4 Pole, 4 Lead, Single Phase ....... UCI274G-311, 4 Pole, 12 Lead re-connectable, Three Phase ........................ UCI274F-17, 4 Pole, 6 Lead, 600 V, Three Phase Exciter ..................................................... Brushless, shunt excited Voltage Regulator ....................................... Solid State, HZ/Volts Voltage Regulation ................................ ½%, No load to full load Frequency ............................................................................ 60 HZ Frequency Regulation ........ ± ½% (1/2 cycle, no load to full load) Unbalanced Load Capability ..................... 100% of standby amps Total Stator and Load Insulation ........................... Class H, 180°C Temperature Rise ......... 120°C R/R, standby rating @ 40°C amb. 1 Ø Motor Starting @ 30% Voltage Dip (240V) ............ 560 kVA 3 Ø Motor Starting @ 30% Voltage Dip (208-240V) ..... 580 kVA 3 Ø Motor Starting @ 30% Voltage Dip (480V) ............ 740 kVA 3 Ø Motor Starting @ 30% Voltage Dip (600V) ............ 665 kVA Bearing ..................................................... 1, Pre-lubed and sealed Coupling .......................................................... Direct flexible disc Total Harmonic Distortion ............... Max 3½% (MIL-STD705B) Telephone Interference Factor ............ Max 50 (NEMA MG1-22) Deviation Factor ................................. Max 5% (MIL-STD 405B) Ltd. Warranty Period .................. 24 Months from start-up date or ........................................................ 1000 hours use, first to occur

ENGINE ___________________________________

Manufacturer ............................................................... John Deere Model and Type .................... 6068HF285, 4 cycle, liquid Cooled Aspiration ................................................................ Turbocharged Charged Air Cooled System ……………….………… Air to Air Cylinder Arrangement ................................... 6 Cylinders, In-Line Displacement Cu. In. (Liters) .......................................... 415 (6.8) Bore & Stroke In. (Cm.) .............................. 4.19 x 5 (10.6 x 12.7) Compression Ratio .............................................................. 19.0:1 Main Bearings & Style .............................Tin-Aluminum, Babbitt Cylinder Head ................................................................. Cast Iron Pistons ............................................................ 6, Aluminum Alloy Crankshaft ................................................... Forged Chrome Steel Exhaust Valve ................................... Forged Heat Resistant Steel Governor ............................... JDEC Electronic L16 DENSO HP3 Frequency Regulation ........................................................ ± 1/4% Air Cleaner ......................................... Dry, Replaceable Cartridge Engine Speed ................................................................. 1800 rpm Max Power, bhp (kwm) Standby .................. ................ 237 (177) BMEP: psi (kpa) Standby ............................. .............. 252 (1735) Ltd. Warranty Period ........... 24 months or 2000 hrs, first to occur

FUEL SYSTEM ____________________________

Type ......................................... Diesel Fuel Oil (ASTM No. 2-D) Combustion System ............................................. Direct Injection Fuel Injection Pump ................................. Stanadyne Rotary Type 12 VDC air intake heaters ............................. Standard Equipment Fuel Filter and Water Separator……………………………Yes

GENERATOR FEATURES

• World Renown Stamford Electric Generator having UL-1446 certification.

• Full generator protection with Deep Sea 7420 controller, having UL-508 certification.

• Automatic voltage regulator with over-excitation, under-frequency compensation, under-speed protection, and EMI filtering. Entire solid-state board is encapsulated for moisture protection.

• Generator power ratings are based on temperature rise, measured by resistance method, as defined in MIL-STD 705C and IEEE STD 115, Method 6.4.4.

• Power ratings will not exceed temperature rise limitation for class H insulation as per NEMA MG1-22.40.

• Insulation resistance to ground, exceeds 1.5 meg-ohm. • Stator receives 2000 V. hi-potential test on main windings,

and rotor windings receive a 1500 V. hi-potential test, as per MIL-STD 705B.

• Full amortisseur windings with UL-1446 certification. • Complete engine-generator torsional acceptance, confirmed

during initial prototype testing.

• Full load testing on all engine-generator sets, before shipping. • Self ventilating and drip-proof & revolving field design

FUEL CONSUMPTION

GAL/HR (LITER/HR) STANDBY

100% LOAD 12.1 (45.8) 75% LOAD 9.4 (35.6) 50% LOAD 6.2 (23.5)

OIL SYSTEM

Type ......................................................................... Full Pressure Oil Pan Capacity qt. (L) ..................................................25 (23.9) Oil Pan Cap. W/ filter qt. (L) ..........................................26 (24.6) Oil Filter .................................................. 1, Replaceable Spin-On

ELECTRICAL SYSTEM _____________________

Ignition System ............................................................. Electronic Eng. Alternator/Starter: 12 VDC, negative ground, 65 amp/hr.

Recommended Battery to -18°C (0°F): ... 12 VDC, Size BCI# 27, Max Dimensions: ........ 12" lg X 6 3/4” wi X 9" hi, with standard round posts. Min output at 700 CCA. Battery tray (max. dim. at 12”lg x 7”wi), hold down straps, battery cables, and battery charger, is furnished. Installation of (1) starting battery is required, with possible higher AMP/HR rating, as described above, if normal environment averages -13°F (-25°C) or cooler.

CERTIFICATIONS

All engines are CARB and EPA emissions certified. All stationary diesel engines are Tier III compliant.

APPLICATION AND ENGINEERING DATA FOR MODEL SPJD-1550-60 HZ

ENGINE SPECIFICATIONS AND APPLICATIONS DATA

Page 3: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Gillette Generators, Inc. •••• 2921 Thorne Dr. •Elkhart, IN • 46514 • Ph: 574-264-9639 • Fax: 574-262-1840 • Web: www.gillettegenerators.com • spc4-190719 3

COOLING SYSTEM

Type of System ............................ Air to Air, Charged Air Cooler Coolant Pump ..................................... Pre-lubricated, self-sealing Cooling Fan Type (no. of blades) ................................. Pusher (7) Fan Diameter inches (cm) ............................................. 22" (55.9) Ambient Capacity of Radiator °F (°C) .......................... 125 (51.6) Engine Jacket Coolant Capacity Qt. (L) ......................... 13 (12.3) Radiator Coolant Capacity Qt. (L) .................................. 24 (22.7) Water Pump Capacity gpm (L/min) .............. ............... 48 (181.7) Heat Reject Coolant: Btu/min (kw) ............. ............. 5324 (93.5) Air to Air Heat Reject(kw) .......................... ................ 1821 (32) Low Radiator Coolant Level Shutdown……………...…Standard Note: Coolant temp. shut-down switch setting at 212°F (100°C) with 50/50 (water/antifreeze) mix.

COOLING AIR REQUIREMENTS

Combustion Air cfm (m3/min) ...................... ............... 480 (13.6) Max Air Intake Restrictions: Clean Air Cleaner, H2O (KPa) ............... ................. 15 (3.75) Intake Manifold Pressure, Psi (kPa) .............. ................. 27 (187) Max. Allowable Temp. Rise, Amb. Air to Eng. Inlet, °F (°C) ....................... ................. …15 (8) Max. Temp. out of Charger Air Cooler @ 77° F (25°C), Amb. Air °F (°C) ........ ................. 140 (60) Radiator Cooling Air, SCFM (m3/min)………….....8000 (226.5)

EXHAUST SYSTEM Exhaust Outlet Size ................................................................. 3.5" Max. Back Pressure in H2O (kpa) ..................................... 30 (7.5) Exhaust Flow, at rated KW, cfm (m3/min) ... ................ 1201 (34) Exhaust Temp, at rated KW, °F (ºC)............. ................ 941 (505)

Deep Sea 7420

The “7420” controller is an auto start mains (utility) failure module for single gen-set applications. This controller includes a backlit LCD display which continuously displays the status of the engine and generator at all times.

The “7420” controller will also monitor speed, frequency, voltage, current, oil pressure, coolant temp., and fuel levels. These modules have been designed to display warning and shut down status. It also includes: (11) configurable inputs • (8) configurable outputs • voltage monitoring • mains (utility) failure detection • (250) event logs • configurable timers • automatic shutdown or warning during fault detection • remote start (on load) • engine preheat • advanced metering capability • hour meter • text LCD displays • protected solid state outputs • test buttons for: stop/reset • manual mode • auto mode • lamp test • start button • power monitoring (kWh, kVAr, kVAh, kVArh)

SOUND LEVELS MEASURED IN dB(A) Open Level 2 Set Encl. Level 2, Critical Silencer ......................... 84............ ........... 75 Level 3, Hospital Silencer ........................................ ........... 70

Note: Open sets (no enclosure) have silencer system choices due to unknown job-site applications. Level 2 enclosure has installed critical silencer with upgrade to Level 3 hospital silencer. Sound tests are averaged from several test points and taken at 23 ft. (7 m) from source of noise at normal operation.

DERATE GENERATOR FOR ALTITUDE

3% per 1000 ft.(305 meters) above 3000 ft. (914 meters) from sea level.

DERATE GENERATOR FOR TEMPERATURE

2% per 10°F (12°C) above 104°F (40°C)

DIMENSIONS AND WEIGHTS Open Level 2 Set Enclosure Length in (cm) ......................... 110 (280) ..... ................ 134 (341) Width in (cm) ........................... 48 (122) ...... ................. 48 (122) Height in (cm) .......................... 55 (140) ...... ............... 72.5 (183) 1 Ø Net Weight lbs (kg) ........ 3269 (1483) ... ............ 4319 (1959) 1 Ø Ship Weight lbs (kg) ...... 3429 (1555) ... ............ 4644 (2106) 3 Ø Net Weight lbs (kg) ........ 3209 (1455) ... ............ 4169 (1891) 3 Ø Ship Weight lbs (kg) ...... 3459 (1568) ... ............ 4489 (2036)

This controller includes expansion features including RS232, RS484 (using MODBUS-RTU/TCP), direct USB connection with PC, expansion optioned using DSENet for remote annunciation and remote relay interfacing for a distance of up to 3300FT. The controller software is freely downloadable from the internet and allows monitoring with direct USB cable, LAN, or by internet via the built in web interface.

Further expansion is available by adding the optional “WebNet“ gateway interface module. This device will allow comprehensive monitoring of the generator via the cloud including identification, location, and status. Some advantages of this module include: reduced site visits and maintenance costs • remote fuel management • fault analysis • asset tracking • automatic system alerts • maximized system up-time.

APPLICATION AND ENGINEERING DATA FOR MODEL SPJD-1550-60 HZ

DEEP SEA 7420 DIGITAL MICROPROCESSOR CONTROLLER

Page 4: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Gillette Generators, Inc. •••• 2921 Thorne Dr. •Elkhart, IN • 46514 • Ph: 574-264-9639 • Fax: 574-262-1840 • Web: www.gillettegenerators.com • spc4-190719 4

CONTROL PANEL: Deep Sea 7420 digital microprocessor with logic allows programming in the field. Controller has: • STOP-MANUAL-AUTO modes and automatic engine

shutdowns, signaled by full text LCD indicators: • Low oil pressure Engine fail to start • High engine temp Engine over speed Low Radiator Level Engine under speed Three auxiliary alarms Over & under voltage Battery fail alarm

Also included is tamper-proof engine hour meter

ENGINE:

Full flow oil filter • Air filter • Oil pump • Solenoid type starter motor • Hi-temp radiator • Jacket water pump • Thermostat • Pusher fan and guard • Exhaust manifold • 12 VDC battery charging alternator • Flexible exhaust connector • ”Isochronous” duty, electronic governor • Vibration isolators • Closed coolant recovery system with 50/50 water to anti-freeze mixture • flexible oil & radiator drain hose.

AC GENERATOR SYSTEM:

AC generator • Shunt excited • Brushless design • Circuit Breaker installed and wired to gen-set • Direct connection to engine with flex disc • Class H, 180°C insulation • Self ventilated • Drip proof construction • UL Certified

VOLTAGE REGULATOR:

½% Voltage regulation • EMI filter • Under-speed protection • Over-excitation protection • total encapsulation

DC ELECTRICAL SYSTEM:

Battery tray • Battery cables • Battery hold down straps • 2-stage battery float charger with maintaining & recharging automatic charge stages

WEATHER/SOUND PROOF ALUMINUM HOUSING

CORROSION RESISTANT PROTECTION CONSISTING OF:

• 9 Heated And Agitated Wash Stages • Zinc Phosphate Etching-coating Stage • Final Baked On Enamel Powder Coat • 18/8 Stainless Steel Hardware

STANDARD FEATURES FOR MODEL SPJD-1550-60 HZ

STANDARD FEATURES

Design & specifications subject to change without prior notice. Dimensions shown are approximate. Contact Gillette for certified drawings. DO NOT USE DIMENSIONS FOR INSTALLATION PURPOSES.

Page 5: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Engi

ne P

erfo

rman

ce C

urve

s60

68 -

Gen

erat

orO

ctob

er 2

006

Ref

: En

gine

Em

issi

on L

abel

Tier

-3 E

mis

sion

Cer

tific

atio

ns:

Cer

tifie

d by

:

Not

es:

ENG

INE

PER

FOR

MA

NC

E C

URV

E

Air I

ntak

e R

estri

ctio

n...

......

......

....1

2 in

.H2O

(3 kP

a)

Exha

ust B

ack

Pres

sure

......

.....

30 in

.H2O

(7.5

kPa

)

Gro

ss p

ower

gua

rant

eed

with

in +

or -

5%

at S

AE J

1995

an

d IS

O 3

046

cond

ition

s:77

°F (2

5 °C

) air

inle

t tem

pera

ture

29.3

1 in

.Hg

(99

kPa)

bar

omet

er10

4 °F

(40

°C) f

uel i

nlet

tem

pera

ture

0.85

3 fu

el s

peci

fic g

ravi

ty @

60

°F (1

5.5

°C)

Con

vers

ion

fact

ors:

Pow

er:

kW =

hp

x 0.

746

Fuel

: 1

gal =

7.1

lb,

1 L

= 0.

85 k

gTo

rque

: N

•m =

lb-ft

x 1

.356

All v

alue

s ar

e fro

m c

urre

ntly

ava

ilabl

e da

ta a

nd a

re s

ubje

ct

to c

hang

e w

ithou

t not

ice.

STAN

DAR

D C

ON

DIT

ION

S

All O

EM G

en S

et E

ngin

e Ap

plic

atio

ns m

ust

be p

re-

scre

ened

for

tors

iona

l vib

ratio

n co

mpa

tibilit

y w

ith th

ere

spec

tive

alte

rnat

or e

nd h

ardw

are.

OEM

Eng

ine

Appl

icat

ion

Engi

neer

ing

will

perfo

rm th

isco

mpu

ter-b

ased

ana

lysis

wor

k up

on re

ques

t.

- PR

IME

- STA

ND

BY

70 (32) 50 (23) 30 (14)

Fuel -- lb/hr (kg/hr)

20 (15)

220

(164

)26

0(1

90)

140

(104

)18

0(1

34)

60 (45)

100

(75) B

rake

Pow

er --

hp

(kW

)

300

(224

)

Pow

erTe

ch E

TM 6

.8L

Engi

neM

odel

: 606

8HF2

85

216

hp (1

61 k

W) P

rime

237

hp (1

77 k

W) S

tand

by

[See

Opt

ion

Cod

e Ta

bles

]

Rat

ing:

Gro

ss P

ower

Appl

icat

ion:

Gen

erat

or (6

0 H

z)Ta

rget

:15

0 kW

e St

andb

y M

arke

t

* Rev

ised

Dat

aC

urve

606

8HF2

8518

0023

7...

......

......

......

......

..She

et 1

of 2

Oct

ober

200

6

Nom

inal

Eng

ine

Pow

er @

180

0 RP

M

Prim

eSt

andb

y

HP

kWH

PkW

216

161

237

177

Gen

erat

or

Effic

ienc

y %

Fan

Pow

er(6

% o

f Sta

ndby

)Po

wer

Fa

ctor

Prim

e R

atin

g 2

Stan

dby

Rat

ing

1,2

ISO

852

8 G

2 Bl

ock

Load

C

apab

ility

hpkW

kWe

kVA

kWe

kVA

88-9

213

.19.

80.

813

3-13

916

6-17

414

7-15

418

4-19

3N

AN

ote

1: B

ased

on

nom

inal

eng

ine

pow

er. D

erat

e 20

% fo

r 100

% b

lock

load

cap

abilit

y.N

ote

2: k

We

/ kVA

ratin

g as

sum

es 9

0% e

ffici

ency

. “G

ener

ator

Effi

cien

cy %

” will

vary

.

CA

RB

; EPA

Page 6: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Engi

ne P

erfo

rman

ce C

urve

s60

68 -

Gen

erat

orN

ovem

ber 2

006

All v

alue

s at

rate

d sp

eed

and

pow

er w

ith s

tand

ard

optio

ns u

nles

s ot

herw

ise

note

d.

Engi

ne In

stal

latio

n C

riter

iaG

ener

al D

ata

Mod

el...

......

......

......

......

......

......

......

......

......

......

6068

HF2

85N

umbe

r of C

ylin

ders

......

......

......

......

......

......

......

......

......

...6

Bore

and

Stro

ke--i

n. (m

m)..

......

......

4.19

x 5

.00

(106

x 1

27)

Dis

plac

emen

t--in

.3 (L).

......

......

......

......

......

......

......

415

(6.8

)C

ompr

essi

on R

atio

......

......

......

......

......

......

......

......

...19

.0:1

Valv

es p

er C

ylin

der--

Inta

ke/E

xhau

st...

......

......

......

......

.2 /

2Fi

ring

Ord

er...

......

......

......

......

......

......

......

......

....1

-5-3

-6-2

-4C

ombu

stio

n Sy

stem

......

......

......

......

......

......

...U

nit I

njec

tion

Engi

ne T

ype.

......

......

......

......

......

......

......

.....

In-li

ne, 4

-Cyc

leAs

pira

tion.

......

......

......

......

......

......

......

......

.....T

urbo

char

ged

Cha

rge

Air C

oolin

g Sy

stem

......

......

......

......

......

.....A

ir-to

-Air

Engi

ne C

rank

case

Ven

t Sys

tem

......

......

......

......

......

..O

pen

Phys

ical

Dat

aLe

ngth

--in.

(mm

)....

......

......

......

......

......

......

......

.44.

2 (1

123)

Wid

th--i

n. (m

m).

......

......

......

......

......

......

......

......

..25.

9 (6

57)

Hei

ght--

in. (

mm

)....

......

......

......

......

......

......

......

..40.

8 (1

036)

Wei

ght,

with

oil-

-lb (k

g)...

......

......

......

......

......

......

1340

(608

) (In

clud

es fl

ywhe

el h

sg.,

flyw

heel

& e

lect

rics)

Cen

ter o

f Gra

vity

Loc

atio

n (E

stim

ated

bas

ed o

n Ti

er 2

)Fr

om R

ear F

ace

of B

lock

(X-a

xis)

--in.

(mm

).14

.5 (3

69)

Rig

ht o

f Cra

nksh

aft (

Y-ax

is)--

in. (

mm

)....

......

......

0.1

(3)

Abov

e C

rank

shaf

t (Z-

axis

)--in

. (m

m).

......

......

.6.1

(154

)M

ax. A

llow.

Sta

tic B

endi

ng M

omen

t at R

ear

Face

of F

lyw

hl H

sg w

/ 5-G

Loa

d--lb

-ft (N

•m).

.600

(814

)Th

rust

Bea

ring

Load

Lim

it --l

b (N

)Fo

rwar

dR

earw

ard

Inte

rmitt

ent..

......

......

......

......

..899

(400

0)...

..450

(200

0)C

ontin

uous

......

......

......

......

...49

5 (2

200)

.....2

25 (1

000)

Max

. Fro

nt o

f Cra

nk. T

orsi

onal

Vib

ratio

n--D

DA

......

......

0.25

Max

. Con

tinuo

us D

ampe

r Tem

p--°

F (°

C).

......

......

..180

(82)

Elec

tric

al S

yste

m12

Vol

t24

Vol

tM

in. B

atte

ry C

apac

ity (C

CA)

--am

p....

......

..800

......

......

570

Max

. Allo

w. S

tart.

Circ

’t R

esis

t.--O

hm..0

.001

2...

......

0.00

2St

arte

r Rol

ling

Cur

rent

:At

32

°F (

0 °C

)--am

p...

......

......

......

......

.920

......

......

600

At -2

2 °F

(-30

°C)--

amp.

......

......

......

....1

300

......

......

700

Min

. Vol

ts a

t EC

U w

hile

Cra

nkin

g--v

olts

......

...6

......

......

..10

Max

. EC

U T

empe

ratu

re--°

F (°

C).

......

......

.....2

21 (1

05)

Max

. Har

ness

Tem

pera

ture

--°F

(°C

)....

......

..248

(120

)M

axim

um V

olta

ge F

rom

Eng

ine

Cra

nksh

aft/

Gen

erat

or S

haft

to G

roun

d--V

AC*.

......

..0.1

5*...

......

0.15

*

Air

Syst

emPr

ime

Stan

dby

Max

. Allo

wab

le T

emp

Ris

e--A

mbi

ent A

ir to

Engi

ne In

let--

°F (°

C)..

......

......

......

......

......

.....1

5 (8

)M

axim

um A

ir In

take

Res

trict

ion

Dirt

y Ai

r Cle

aner

--in.

H2O

(kPa

).....

......

....2

5 (6

.25)

Cle

an A

ir C

lean

er--i

n.H

2O (k

Pa)..

......

.....1

5 (3

.75)

Engi

ne A

ir Fl

ow--f

t3 /m

in (m

3 /m

in).

...47

0 (1

3.3)

..480

(13.

6)Ai

r Cle

aner

Effi

cien

cy--%

......

......

......

......

......

...99

.9

Cha

rge

Air

Coo

ling

Syst

emPr

ime

Stan

dby

Air/A

ir Ex

chan

ger H

eat R

ejec

tion-

-BT

U/m

in (k

W).

......

......

......

......

......

....1

702(

29.9

)...

1821

(32.

0)C

ompr

ess.

Dis

chrg

. Tem

p.(R

ated

)@

77

°F (2

5°C

) Am

b. A

ir--°

F (°

C)3

52(1

78).

...36

9(18

7)C

ompr

ess.

Dis

chrg

. Tem

p.(M

ax.)

@ 4

7°C

am

b. a

nd

80 k

Pa b

ar.--

°F (°

C).

......

......

......

...N

A (N

A)...

..NA

(NA)

Pres

s. D

rop,

thru

CAC

--in.

H2O

(kPa

)M

ax. .

......

......

......

......

......

......

......

......

......

.64

(16)

Min

. ....

......

......

......

......

......

......

......

......

......

.32

(8)

Inta

ke M

anifo

ld P

ress

ure-

-psi

(kPa

)...2

5 (1

70).

....2

7 (1

87)

CAC

Out

Tem

p @

77°

F (2

5°C

) Am

b.--°

F (°

C)

Max

. ...

......

......

......

......

......

......

......

......

.....1

40 (6

0)M

in.

......

......

......

......

......

......

......

......

......

...11

8 (4

8)C

AC O

ut T

emp

@ a

ny A

mbi

ent--

°F (°

C)

Max

.....

......

......

......

......

......

......

......

......

.....1

90 (8

8)

Coo

ling

Syst

emPr

ime

Stan

dby

Engi

ne H

eat R

ejec

t.--B

TU/m

in (k

W)..

.NA

(NA)

..53

24 (9

3.5)

Coo

lant

Flo

w--g

al/m

in (L

/min

).....

......

...48

(180

)....

..48(

180)

Ther

mos

tat S

tart

to O

pen-

-°F

(°C

)....

......

.....1

80 (8

2)Th

erm

osta

t Ful

ly O

pen-

-°F

(°C

).....

......

......

..203

(95)

Engi

ne C

oola

nt C

apac

ity--q

t (L)

......

......

.....1

3 (1

1.9)

Min

. Pre

ssur

e C

ap--p

si (k

Pa).

......

......

......

14.5

(100

)M

ax. T

op T

ank

Tem

p--°

F (°

C).

......

......

......

.230

(110

)M

in. C

oola

nt F

ill R

ate-

-gal

/min

(L/m

in).

......

.....3

(11)

M

in. A

ir-to

-Boi

l Tem

pera

ture

--°F

(°C

)....

......

117

(47)

Min

. Pum

p In

let P

ress

ure-

-psi

(kPa

).....

......

..4.4

(30)

Exha

ust S

yste

mPr

ime

Stan

dby

Exha

ust F

low

--ft3 /

min

(m3 /

min

).....

.116

5 (3

3.0)

.120

1(34

.0)

Exha

ust T

empe

ratu

re--°

F (°

C).

......

...91

6 (4

91).

..941

(505

)M

ax. E

xhau

st R

estri

ctio

n----

in. H

2O (k

Pa)..

....3

0 (7

.5)

Min

. Exh

aust

Res

trict

ion-

---in

. H2O

(kPa

).....

......

Non

eM

ax. B

end.

Mom

ent,

Turb

o O

ut.--

lb-ft

(N•m

).5.

2 (7

.0)

Max

. She

ar o

n Tu

rbo

Out

let--

lb (k

g)...

......

......

.24

(11)

Fuel

Sys

tem

Prim

eSt

andb

yEC

U D

escr

iptio

n...

......

......

......

......

......

..L16

Con

trolle

rFu

el In

ject

ion

Pum

p ...

......

......

......

......

......

Den

so H

P3G

over

nor T

ype.

......

......

......

......

......

......

......

.Ele

ctro

nic

Tota

l Fue

l Flo

w--l

b/hr

(kg/

hr)..

......

...18

5(84

.0).

....2

01(9

1.2)

Fuel

Con

sum

ptio

n--lb

/hr (

kg/h

r)...

......

..77(

35).

......

..84

(38)

Max

. Fue

l Inl

et T

emp.

--°F

(°C

)....

......

......

......

.176

(80)

Fuel

Tem

p. R

ise,

Inlt

to R

etrn

--°F

(°C

)75.

6(42

)....

....8

1(45

)M

ax. F

uel I

nlet

Res

trict

ion-

-in. H

2O (k

Pa).

......

80 (2

0)M

ax. F

uel I

nlet

Pre

ssur

e--in

. H2O

(kPa

)....

....N

A (N

A)M

ax. F

uel R

etur

n Pr

essu

re--i

n. H

2O (k

Pa).

.....8

0 (20

)

Lubr

icat

ion

Syst

emPr

ime

Stan

dby

Oil

Pres

s. a

t Rat

ed S

peed

--psi

(kPa

).44

(300

)....

.44

(300

)M

in.O

il Pr

essu

re--p

si (k

Pa)..

......

......

......

......

..15

(105

)M

ax. O

il C

arry

over

in B

low

-by-

-lb/h

r (g/

hr)0

.002

(1.0

)M

ax. A

irflo

w in

Blo

w-b

y--g

al/m

in (l

/min

).....

....3

4 (1

30)

Max

. Cra

nkca

se P

ress

ure-

-in. H

2O (k

Pa)..

......

.2 (0

.5)

Perf

orm

ance

Dat

aPr

ime

Stan

dby

Rat

ed P

ower

--hp

(kW

)....

......

......

...21

6 (1

61)..

....2

37 (1

77)

Rat

ed S

peed

--rpm

......

......

......

......

......

..18

00...

......

....1

800

Low

Idle

Spe

ed--r

pm...

......

......

......

......

..115

0....

......

....1

150

Rat

ed T

orqu

e--lb

-ft (N

•m)..

......

.....

1158

(854

)....1

273

(939

)BM

EP--p

si (k

Pa).

......

......

......

......

.229

(157

8)...

.252

(173

5)Fr

ictio

n Po

wer

@

Rat

ed S

peed

--hp

(kW

)....

......

....2

3 (1

7)...

......

.23

(17)

Altit

ude

Cap

abilit

y--ft

(m).

......

......

10,0

00(3

050)

...10

,000

(305

0)R

atio

--Air

: Fue

l.....

......

......

......

......

......

.25

: 1...

......

...24

: 1

Smok

e @

Rat

ed S

peed

--Bos

ch N

o....

...0.

43...

......

.....

0.74

Noi

se--d

B(A)

@ 1

m...

......

......

......

......

.....

NA.

......

......

...N

A

Fuel

Con

sum

ptio

n --

lb/h

r (kg

/h)

Prim

eSt

andb

y

25 %

Pow

er...

......

......

......

......

......

..NA

(NA)

......

24.3

(11.

0)50

% P

ower

......

......

......

......

......

.....N

A (N

A)...

...47

.4 (2

1.5)

75 %

Pow

er...

......

......

......

......

......

..NA

(NA)

......

65.0

(29.

5)10

0 %

Pow

er...

......

......

......

......

......

NA

(NA)

......

83.8

(38.

0)

* Rev

ised

Dat

aC

urve

606

8HF2

8518

0023

7....

......

......

......

......

....S

heet

2 o

f 2O

ctob

er 2

006

Page 7: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274H - Winding 06

Technical Data Sheet

Page 8: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274HSPECIFICATIONS & OPTIONS

STANDARDSStamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of otherinternational standards such as BS5000, VDE 0530,NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.

VOLTAGE REGULATORS

SX460 AVR - STANDARDWith this self excited control system the main statorsupplies power via the Automatic Voltage Regulator (AVR)to the exciter stator. The high efficiency semiconductors ofthe AVR ensure positive build-up from initial low levels ofresidual voltage.The exciter rotor output is fed to the main rotor through athree phase full wave bridge rectifier. This rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit.

AS440 AVRWith this self-excited system the main stator providespower via the AVR to the exciter stator. The highefficiency semi-conductors of the AVR ensure positivebuild-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through athree-phase full-wave bridge rectifier. The rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permitparallel operation with other ac generators.

TERMINALS & TERMINAL BOX

Dedicated Single Phase windings have 4 ends brought outto the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It hasremovable panels for easy access.

SHAFT & KEYS

All generator rotors are dynamically balanced to betterthan BS6861:Part 1 Grade 2.5 for minimum vibration inoperation. Two bearing generators are balanced with a halfkey.

INSULATION/IMPREGNATION

The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanicalstrength required for rotating components.

QUALITY ASSURANCE

Generators are manufactured using production procedureshaving a quality assurance level toBS EN ISO 9001.

The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any changein performance will fall within the limits of Criteria 'B' of EN61000 6 2:2001 At no time will the steady state voltage

STANDARDSStamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of otherinternational standards such as BS5000, VDE 0530,NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.

VOLTAGE REGULATORS

SX460 AVR - STANDARDWith this self excited control system the main statorsupplies power via the Automatic Voltage Regulator (AVR)to the exciter stator. The high efficiency semiconductors ofthe AVR ensure positive build-up from initial low levels ofresidual voltage.The exciter rotor output is fed to the main rotor through athree phase full wave bridge rectifier. This rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit.

AS440 AVRWith this self-excited system the main stator providespower via the AVR to the exciter stator. The highefficiency semi-conductors of the AVR ensure positivebuild-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through athree-phase full-wave bridge rectifier. The rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permitparallel operation with other ac generators.

MX341 AVRThis sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the main exciter,giving a source of constant excitation power independentof generator output. The main exciter output is then fed tothe main rotor, through a full wave bridge, protected by asurge suppressor. The AVR has in-built protection againstsustained over-excitation, caused by internal or externalfaults. This de-excites the machine after a minimum of 5seconds.An engine relief load acceptance feature can enable fullload to be applied to the generator in a single step.

MX321 AVRThe most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally over voltageprotection built-in and short circuit current leveladjustments as an optional facility.

WINDINGS & ELECTRICAL PERFORMANCE

All generator stators are wound to 2/3 pitch. Thiseliminates triplen (3rd, 9th, 15th …) harmonics on thevoltage waveform and is found to be the optimum designfor trouble-free supply of non-linear loads. The 2/3 pitchdesign avoids excessive neutral currents sometimes seenwith higher winding pitches, when in parallel with themains. A fully connected damper winding reducesoscillations during paralleling. This winding, with the 2/3pitch and carefully selected pole and tooth designs,ensures very low waveform distortion.

TERMINALS & TERMINAL BOX

Dedicated Single Phase windings have 4 ends brought outto the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It hasremovable panels for easy access.

SHAFT & KEYS

All generator rotors are dynamically balanced to betterthan BS6861:Part 1 Grade 2.5 for minimum vibration inoperation. Two bearing generators are balanced with a halfkey.

INSULATION/IMPREGNATION

The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanicalstrength required for rotating components.

QUALITY ASSURANCE

Generators are manufactured using production procedureshaving a quality assurance level toBS EN ISO 9001.

The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any changein performance will fall within the limits of Criteria 'B' of EN61000-6-2:2001. At no time will the steady-state voltageregulation exceed 2%.

DE RATES

All values tabulated on page 7 are subject to the followingreductions

5% when air inlet filters are fitted.3% for every 500 metres by which the operating altitudeexceeds 1000 metres above mean sea level.3% for every 5 C by which the operational ambienttemperature exceeds 40 C.

Note: Requirement for operating in an ambient exceeding60 C must be referred to the factory.

NB Continuous development of our products entitles us tochange specification details without notice, therefore theymust not be regarded as binding.

Front cover drawing typical of product range.

STANDARDSStamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of otherinternational standards such as BS5000, VDE 0530,NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.

VOLTAGE REGULATORS

SX460 AVR - STANDARDWith this self excited control system the main statorsupplies power via the Automatic Voltage Regulator (AVR)to the exciter stator. The high efficiency semiconductors ofthe AVR ensure positive build-up from initial low levels ofresidual voltage.The exciter rotor output is fed to the main rotor through athree phase full wave bridge rectifier. This rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit.

AS440 AVRWith this self-excited system the main stator providespower via the AVR to the exciter stator. The highefficiency semi-conductors of the AVR ensure positivebuild-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through athree-phase full-wave bridge rectifier. The rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permitparallel operation with other ac generators.

MX341 AVRThis sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the main exciter,giving a source of constant excitation power independentof generator output. The main exciter output is then fed tothe main rotor, through a full wave bridge, protected by asurge suppressor. The AVR has in-built protection againstsustained over-excitation, caused by internal or externalfaults. This de-excites the machine after a minimum of 5seconds.An engine relief load acceptance feature can enable fullload to be applied to the generator in a single step.

MX321 AVRThe most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally over voltageprotection built-in and short circuit current leveladjustments as an optional facility.

WINDINGS & ELECTRICAL PERFORMANCE

All generator stators are wound to 2/3 pitch. Thiseliminates triplen (3rd, 9th, 15th …) harmonics on thevoltage waveform and is found to be the optimum designfor trouble-free supply of non-linear loads. The 2/3 pitchdesign avoids excessive neutral currents sometimes seenwith higher winding pitches, when in parallel with themains. A fully connected damper winding reducesoscillations during paralleling. This winding, with the 2/3pitch and carefully selected pole and tooth designs,ensures very low waveform distortion.

TERMINALS & TERMINAL BOX

Dedicated Single Phase windings have 4 ends brought outto the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It hasremovable panels for easy access.

SHAFT & KEYS

All generator rotors are dynamically balanced to betterthan BS6861:Part 1 Grade 2.5 for minimum vibration inoperation. Two bearing generators are balanced with a halfkey.

INSULATION/IMPREGNATION

The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanicalstrength required for rotating components.

QUALITY ASSURANCE

Generators are manufactured using production procedureshaving a quality assurance level toBS EN ISO 9001.

The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any changein performance will fall within the limits of Criteria 'B' of EN61000-6-2:2001. At no time will the steady-state voltageregulation exceed 2%.

DE RATES

All values tabulated on page 7 are subject to the followingreductions

5% when air inlet filters are fitted.3% for every 500 metres by which the operating altitudeexceeds 1000 metres above mean sea level.3% for every 5 C by which the operational ambienttemperature exceeds 40 C.

Note: Requirement for operating in an ambient exceeding60 C must be referred to the factory.

NB Continuous development of our products entitles us tochange specification details without notice, therefore theymust not be regarded as binding.

Front cover drawing typical of product range.

2

Page 9: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.

A.V.R. MX341 MX321

VOLTAGE REGULATION ± 1% ± 0.5 % With 4% ENGINE GOVERNING

SUSTAINED SHORT CIRCUIT

CONTROL SYSTEM SELF EXCITED

A.V.R. SX460 AS440

VOLTAGE REGULATION ± 1.0 % ± 1.0 % With 4% ENGINE GOVERNING

SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT

INSULATION SYSTEM

PROTECTION

RATED POWER FACTOR

STATOR WINDING

WINDING PITCH

WINDING LEADS

MAIN STATOR RESISTANCE

MAIN ROTOR RESISTANCE

EXCITER STATOR RESISTANCE

EXCITER ROTOR RESISTANCE

R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others

WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING LINEAR LOAD < 5.0%

MAXIMUM OVERSPEED 2250 Rev/Min

BEARING DRIVE END BALL. 6315-2RS (ISO)

BEARING NON-DRIVE END BALL. 6310-2RS (ISO)

0.091 Ohms PER PHASE AT 22°C

WINDING 06UCI274H

0.8

IP23

CLASS H

REFER TO SHORT CIRCUIT DECREMENT CURVES (page 6)

1.82 Ohms at 22°C

20 Ohms at 22°C

SINGLE LAYER CONCENTRIC

0.007 Ohms AT 22°C SERIES CONNECTED

4

TWO THIRDS

BEARING NON-DRIVE END BALL. 6310-2RS (ISO)

1 BEARING 2 BEARING

WEIGHT COMP. GENERATOR

WEIGHT WOUND STATOR

WEIGHT WOUND ROTOR

WR² INERTIA

SHIPPING WEIGHTS in a crate

PACKING CRATE SIZE

TELEPHONE INTERFERENCE

COOLING AIR

VOLTAGE SERIES

VOLTAGE PARALLELkVA BASE RATING FOR REACTANCE VALUESXd DIR. AXIS SYNCHRONOUS

X'd DIR. AXIS TRANSIENT

X''d DIR. AXIS SUBTRANSIENT

Xq QUAD. AXIS REACTANCE

X''q QUAD. AXIS SUBTRANSIENT

XL LEAKAGE REACTANCE

X2 NEGATIVE SEQUENCE

X0 ZERO SEQUENCE

REACTANCES ARE SATURATED

T'd TRANSIENT TIME CONST. 0.042 s

T''d SUB-TRANSTIME CONST. 0.012 s

T'do O.C. FIELD TIME CONST. 1.1 s

Ta ARMATURE TIME CONST. 0.012 s

SHORT CIRCUIT RATIO 1/Xd

1.21

0.16

0.10

0.15

0.10

0.14

0.09

0.13

0.08

0.080.09

227.53 kg

1.9349 kgm2

0.13

1.44

0.19

0.12

1.32

0.17

0.11

123 x 67 x 103(cm)

TIF<50

659 kg

0.20 0.19 0.17

626 kg

253 kg

123 x 67 x 103(cm)

THF<2%

641 kg

253 kg

216.57 kg

1.8843 kgm2

673 kg

115 120110

240

156.3

0.617 m³/sec 1308 cfm

1.99

220

156.3

2.37

230

156.3

2.17

SHORT CIRCUIT RATIO 1/Xd

3

Page 10: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274HWinding 06

SINGLE PHASE EFFICIENCY CURVES

44

Page 11: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274HWinding 06

Locked Rotor Motor Starting CurvesSX

0

5

10

15

20

25

30

0 50 100 150 200 250 300 350 400 450LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

.

220V 230V 240V

SX

MX

0

5

10

15

20

25

30

0 50 100 150 200 250 300 350 400 450LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

.

220V 230V 240V

0

5

10

15

20

25

30

0 50 100 150 200 250 300 350 400 450 500 550 600LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

.

220V 230V 240V

55

Page 12: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274HWinding 06

Based on series connection.Short Circuit Decrement Curve. No-load Excitation at Rated Speed

Sustained Short Circuit = 2840 Amps

Note

100

1000

10000

100000

0.001 0.01 0.1 1 10TIME (secs)

CUR

REN

T (A

mps

)

SYMMETRICAL

ASYMMETRICAL

Voltage Factor220V X 1.00230V X 1.05240V X 1.09

The sustained current value is constant irrespectiveof voltage level

Sustained Short Circuit = 2840 Amps

NoteThe following multiplication factors should be used to adjust thevalues from curve between time 0.001 seconds and the minimumcurrent point in respect of nominal operating voltage :

100

1000

10000

100000

0.001 0.01 0.1 1 10TIME (secs)

CUR

REN

T (A

mps

)

SYMMETRICAL

ASYMMETRICAL

66

Page 13: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

Class - Temp Rise

Series (V) 220 230 240 220 230 240 220 230 240 220 230 240Parallel (V) 110 115 120 110 115 120 110 115 120 110 115 120

kVA 143.8 143.8 143.8 156.3 156.3 156.3 143.8 143.8 143.8 156.3 156.3 156.3

kW 115.0 115.0 115.0 125.0 125.0 125.0 143.8 143.8 143.8 156.3 156.3 156.3

Efficiency (%) 86.7 86.9 87.2 86.3 86.7 86.9 89.6 89.9 90.1 89.3 89.6 89.9

kW Input 132.6 132.3 131.9 144.8 144.2 143.8 160.5 160.0 159.6 175.0 174.4 173.9

DIMENSIONS

UCI274H

Cont. F - 105/40°C 0.8pf

Cont. H - 125/40°C 0.8pf

Cont. F - 105/40°C 1.0pf

Cont. H - 125/40°C 1.0pf

Winding 06

RATINGS60Hz60Hz

77

Page 14: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274H-06-TD-EN-SG-A

Head Office Address:Barnack Road, StamfordLincolnshire, PE9 2NB

United KingdomTel: +44 (0) 1780 484000Fax: +44 (0) 1780 484100

www.cumminsgeneratortechnologies.com

Copyright 2010, Cummins Generator Technologies Ltd, All Rights ReservedStamford and AvK are registered trade marks of Cummins Generator Technologies Ltd

Cummins and the Cummins logo are registered trade marks of Cummins Inc.

UCI274H-06-TD-EN-SG-A

Head Office Address:Barnack Road, StamfordLincolnshire, PE9 2NB

United KingdomTel: +44 (0) 1780 484000Fax: +44 (0) 1780 484100

www.cumminsgeneratortechnologies.com

Copyright 2010, Cummins Generator Technologies Ltd, All Rights ReservedStamford and AvK are registered trade marks of Cummins Generator Technologies Ltd

Cummins and the Cummins logo are registered trade marks of Cummins Inc.

Page 15: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274G - Winding 311

Technical Data Sheet

Page 16: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274GSPECIFICATIONS & OPTIONS

STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other internationalstandards such as BS5000, VDE 0530, NEMA MG1-32, IEC34,CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.

VOLTAGE REGULATORS

SX460 AVR - STANDARD

With this self excited control system the main stator suppliespower via the Automatic Voltage Regulator (AVR) to the exciterstator. The high efficiency semiconductors of the AVR ensurepositive build-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through a threephase full wave bridge rectifier. This rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit.

AS440 AVR

With this self-excited system the main stator provides power viathe AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial lowlevels of residual voltage.The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permit paralleloperation with other ac generators.

MX341 AVR

This sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the main exciter,giving a source of constant excitation power independent ofgenerator output. The main exciter output is then fed to themain rotor, through a full wave bridge, protected by a surgesuppressor. The AVR has in-built protection against sustainedover-excitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds.An engine relief load acceptance feature can enable full load tobe applied to the generator in a single step.If three-phase sensing is required with the PMG system theMX321 AVR must be used.We recommend three-phase sensing for applications withgreatly unbalanced or highly non-linear loads.

MX321 AVR

The most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally, three-phase rmssensing, for improved regulation and performance.Over voltage protection is built-in and short circuit current leveladjustments is an optional facility.

WINDINGS & ELECTRICAL PERFORMANCE

All generator stators are wound to 2/3 pitch. This eliminatestriplen (3rd, 9th, 15th …) harmonics on the voltage waveformand is found to be the optimum design for trouble-free supplyof non-linear loads. The 2/3 pitch design avoids excessiveneutral currents sometimes seen with higher winding pitches,when in parallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. This winding,with the 2/3 pitch and carefully selected pole and toothdesigns, ensures very low waveform distortion.

TERMINALS & TERMINAL BOX

Standard generators are 3-phase reconnectable with 12 endsbrought out to the terminals, which are mounted on a cover atthe non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It has removablepanels for easy access.

SHAFT & KEYS

All generator rotors are dynamically balanced to better thanBS6861:Part 1 Grade 2.5 for minimum vibration in operation.Two bearing generators are balanced with a half key.

INSULATION/IMPREGNATION

The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanical strengthrequired for rotating components.

QUALITY ASSURANCE

Generators are manufactured using production procedureshaving a quality assurance level to BS EN ISO 9001.

The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any change inperformance will fall within the limits of Criteria 'B' of EN61000-6-2:2001. At no time will the steady-state voltageregulation exceed 2%.

DE RATES

All values tabulated on page 8 are subject to the followingreductions

5% when air inlet filters are fitted.3% for every 500 metres by which the operating altitudeexceeds 1000 metres above mean sea level.3% for every 5°C by which the operational ambienttemperature exceeds 40°C.

Note: Requirement for operating in an ambient exceeding60°C must be referred to the factory. NB Continuous development of our products entitles us tochange specification details without notice, therefore theymust not be regarded as binding.

Front cover drawing typical of product range.

2

Page 17: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.

A.V.R. MX321 MX341

VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING

SUSTAINED SHORT CIRCUIT

CONTROL SYSTEM SELF EXCITED

A.V.R. SX460 AS440

VOLTAGE REGULATION ± 1.0 % ± 1.0 % With 4% ENGINE GOVERNING

SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT

INSULATION SYSTEM CLASS H

PROTECTION

RATED POWER FACTOR

STATOR WINDING

WINDING PITCH

WINDING LEADS

STATOR WDG. RESISTANCE

ROTOR WDG. RESISTANCE

EXCITER STATOR RESISTANCE

EXCITER ROTOR RESISTANCE

R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others

WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%

MAXIMUM OVERSPEED

BEARING DRIVE END

BEARING NON-DRIVE END

WEIGHT COMP. GENERATORWEIGHT WOUND STATORWEIGHT WOUND ROTORWR² INERTIASHIPPING WEIGHTS in a cratePACKING CRATE SIZE

TELEPHONE INTERFERENCECOOLING AIRVOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138kVA BASE RATING FOR REACTANCE VALUES 182 182 182 N/A 205 218 218 231

Xd DIR. AXIS SYNCHRONOUS 2.15 1.94 1.80 - 2.43 2.31 2.11 2.06X'd DIR. AXIS TRANSIENT 0.19 0.17 0.16 - 0.21 0.20 0.18 0.18X''d DIR. AXIS SUBTRANSIENT 0.13 0.12 0.11 - 0.15 0.14 0.13 0.12Xq QUAD. AXIS REACTANCE 1.29 1.16 1.08 - 1.47 1.40 1.28 1.24X''q QUAD. AXIS SUBTRANSIENT 0.18 0.16 0.15 - 0.18 0.17 0.16 0.15XL LEAKAGE REACTANCE 0.08 0.07 0.07 - 0.09 0.08 0.08 0.07X2 NEGATIVE SEQUENCE 0.13 0.12 0.11 - 0.16 0.15 0.13 0.13X0 ZERO SEQUENCE 0.08 0.07 0.07 - 0.10 0.09 0.08 0.08

REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATEDT'd TRANSIENT TIME CONST.T''d SUB-TRANSTIME CONST.T'do O.C. FIELD TIME CONST.Ta ARMATURE TIME CONST.SHORT CIRCUIT RATIO

REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7)

BALL. 6310-2RS (ISO)

1/Xd

0.038 s0.012 s

1 s0.01 s

1.69 Ohms at 22°C

0.0199 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED

BALL. 6315-2RS (ISO)

210.35 kg1.7674 kgm2

IP23

0.8

DOUBLE LAYER CONCENTRIC

TWO THIRDS

12

598 kg580 kg225 kg

UCI274G

0.514 m³/sec 1090 cfm 0.617 m³/sec 1308 cfm

50 HzTHF<2%

60 HzTIF<50

199.39 kg1.7169 kgm2

WINDING 311

20 Ohms at 22°C

0.091 Ohms PER PHASE AT 22°C

630 kg 123 x 67 x 103 (cm)

613 kg 123 x 67 x 103 (cm)

1 BEARING 2 BEARING

2250 Rev/Min

225 kg

3

Page 18: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

Winding 311UCI274G

THREE PHASE EFFICIENCY CURVES

50Hz

4

Page 19: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

Winding 311UCI274G

THREE PHASE EFFICIENCY CURVES

60Hz

5

Page 20: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274GWinding 311

Locked Rotor Motor Starting Curve

MX SX

50Hz

60Hz

MX SX

0

5

10

15

20

25

30

0 100 200 300 400 500 600LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

.

346V 380V 400V 415V

0

5

10

15

20

25

30

0 100 200 300 400 500 600 700 800LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

.

380V 416V 440V 460V 480V

0

5

10

15

20

25

30

0 50 100 150 200 250 300 350 400 450 500 550LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

.

346V 380V 400V 415V

0

5

10

15

20

25

30

0 100 200 300 400 500 600 700LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

.

380V 416V 440V 460V 480V

6

Page 21: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

3-phase 2-phase L-L 1-phase L-NVoltage Factor Voltage Factor x 1.00 x 0.87 x 1.30

380v X 1.00 416v X 1.00 x 1.00 x 1.80 x 3.20400v X 1.07 440v X 1.06 x 1.00 x 1.50 x 2.50415v X 1.12 460v X 1.12 10 sec. 5 sec. 2 sec.

480v X 1.17The sustained current value is constant irrespectiveof voltage level

Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated SpeedBased on star (wye) connection.

Max. sustained durationAll other times are unchanged

Instantaneous

SustainedMinimum

UCI274G

50Hz 60Hz

Sustained Short Circuit = 850 Amps

Sustained Short Circuit = 970 AmpsNote 1The following multiplication factors should beused to adjust the values from curve betweentime 0.001 seconds and the minimum currentpoint in respect of nominal operating voltage :

Note 2The following multiplication factor should be used to convert thevalues calculated in accordance with NOTE 1 to those applicableto the various types of short circuit :

Note 3Curves are drawn for Star (Wye) connected machines. For otherconnection the following multipliers should be applied to currentvalues as shown : Parallel Star = Curve current value X 2Series Delta = Curve current value X 1.732

50Hz

60Hz

10

100

1000

10000

0.001 0.01 0.1 1 10TIME (secs)

CUR

RENT

(Am

ps)

SYMMETRICAL

ASYMMETRICAL

10

100

1000

10000

0.001 0.01 0.1 1 10TIME (secs)

CUR

RENT

(Am

ps)

SYMMETRICAL

ASYMMETRICAL

7

Page 22: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

Class - Temp Rise

Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440

Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220

Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254

kVA 164.6 164.6 164.6 N/A 182.0 182.0 182.0 N/A 187.0 187.0 187.0 N/A 200.0 200.0 200.0 N/A

kW 131.7 131.7 131.7 N/A 145.6 145.6 145.6 N/A 149.6 149.6 149.6 N/A 160.0 160.0 160.0 N/A

Efficiency (%) 92.3 92.6 92.8 N/A 92.0 92.3 92.5 N/A 91.9 92.2 92.5 N/A 91.6 92.0 92.2 N/A

kW Input 142.7 142.2 141.9 N/A 158.3 157.7 157.4 N/A 162.8 162.2 161.8 N/A 174.7 173.9 173.5 N/A

Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480

Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240

Series Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277

kVA 192.8 199.0 199.0 212.2 205.0 218.5 218.5 231.4 213.0 228.8 228.8 250.0 218.5 234.0 234.0 253.3

kW 154.2 159.2 159.2 169.8 164.0 174.8 174.8 185.1 170.4 183.0 183.0 200.0 174.8 187.2 187.2 202.6

Efficiency (%) 92.4 92.7 92.9 93.0 92.2 92.4 92.7 92.7 92.0 92.2 92.5 92.5 91.9 92.1 92.4 92.5

kW Input 166.9 171.7 171.4 182.5 177.9 189.2 188.6 199.7 185.2 198.5 197.9 216.2 190.2 203.3 202.6 219.1

UCI274GWinding 311 / 0.8 Power Factor

RATINGSCont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C

DIMENSIONS

50Hz

60Hz

8

Page 23: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UC274G-311-TD-EN-SG-A

Head Office Address:Barnack Road, StamfordLincolnshire, PE9 2NB

United KingdomTel: +44 (0) 1780 484000Fax: +44 (0) 1780 484100

www.cumminsgeneratortechnologies.com

Copyright 2010, Cummins Generator Technologies Ltd, All Rights ReservedStamford and AvK are registered trade marks of Cummins Generator Technologies Ltd

Cummins and the Cummins logo are registered trade marks of Cummins Inc.

Page 24: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274F - Winding 17

Technical Data Sheet

Page 25: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274FSPECIFICATIONS & OPTIONS

STANDARDS

Stamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of other internationalstandards such as BS5000, VDE 0530, NEMA MG1-32, IEC34,CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.

VOLTAGE REGULATORS

SX460 AVR - STANDARD

With this self excited control system the main stator suppliespower via the Automatic Voltage Regulator (AVR) to the exciterstator. The high efficiency semiconductors of the AVR ensurepositive build-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through a threephase full wave bridge rectifier. This rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit.

AS440 AVR

With this self-excited system the main stator provides power viathe AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial lowlevels of residual voltage.The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permit parallel

WINDINGS & ELECTRICAL PERFORMANCE

All generator stators are wound to 2/3 pitch. This eliminatestriplen (3rd, 9th, 15th …) harmonics on the voltage waveformand is found to be the optimum design for trouble-free supplyof non-linear loads. The 2/3 pitch design avoids excessiveneutral currents sometimes seen with higher winding pitches,when in parallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. This winding,with the 2/3 pitch and carefully selected pole and toothdesigns, ensures very low waveform distortion.

TERMINALS & TERMINAL BOX

Standard generators are 3-phase reconnectable with 12 endsbrought out to the terminals, which are mounted on a cover atthe non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It has removablepanels for easy access.

SHAFT & KEYS

All generator rotors are dynamically balanced to better thanBS6861:Part 1 Grade 2.5 for minimum vibration in operation.

INSULATION/IMPREGNATION

The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanical strengthrequired for rotating components.

STANDARDS

Stamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of other internationalstandards such as BS5000, VDE 0530, NEMA MG1-32, IEC34,CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.

VOLTAGE REGULATORS

SX460 AVR - STANDARD

With this self excited control system the main stator suppliespower via the Automatic Voltage Regulator (AVR) to the exciterstator. The high efficiency semiconductors of the AVR ensurepositive build-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through a threephase full wave bridge rectifier. This rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit.

AS440 AVR

With this self-excited system the main stator provides power viathe AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial lowlevels of residual voltage.The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permit paralleloperation with other ac generators.

MX341 AVR

This sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the main exciter,giving a source of constant excitation power independent ofgenerator output. The main exciter output is then fed to themain rotor, through a full wave bridge, protected by a surgesuppressor. The AVR has in-built protection against sustainedover-excitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds.An engine relief load acceptance feature can enable full load tobe applied to the generator in a single step.If three-phase sensing is required with the PMG system theMX321 AVR must be used.We recommend three-phase sensing for applications withgreatly unbalanced or highly non-linear loads.

MX321 AVR

The most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally, three-phase rmssensing, for improved regulation and performance.Over voltage protection is built-in and short circuit current leveladjustments is an optional facility.

WINDINGS & ELECTRICAL PERFORMANCE

All generator stators are wound to 2/3 pitch. This eliminatestriplen (3rd, 9th, 15th …) harmonics on the voltage waveformand is found to be the optimum design for trouble-free supplyof non-linear loads. The 2/3 pitch design avoids excessiveneutral currents sometimes seen with higher winding pitches,when in parallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. This winding,with the 2/3 pitch and carefully selected pole and toothdesigns, ensures very low waveform distortion.

TERMINALS & TERMINAL BOX

Standard generators are 3-phase reconnectable with 12 endsbrought out to the terminals, which are mounted on a cover atthe non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It has removablepanels for easy access.

SHAFT & KEYS

All generator rotors are dynamically balanced to better thanBS6861:Part 1 Grade 2.5 for minimum vibration in operation.

INSULATION/IMPREGNATION

The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanical strengthrequired for rotating components.

QUALITY ASSURANCE

Generators are manufactured using production procedureshaving a quality assurance level to BS EN ISO 9001.

The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any change inperformance will fall within the limits of Criteria 'B' of EN61000-6-2:2001. At no time will the steady-state voltageregulation exceed 2%.

DE RATES

All values tabulated on page 6 are subject to the followingreductions

5% when air inlet filters are fitted.3% for every 500 metres by which the operating altitudeexceeds 1000 metres above mean sea level.3% for every 5 C by which the operational ambienttemperature exceeds 40 C.

Note: Requirement for operating in an ambient exceeding60 C must be referred to the factory.

NB Continuous development of our products entitles us tochange specification details without notice, therefore theymust not be regarded as binding.

Front cover drawing typical of product range.

STANDARDS

Stamford industrial generators meet the requirements ofBS EN 60034 and the relevant section of other internationalstandards such as BS5000, VDE 0530, NEMA MG1-32, IEC34,CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.

VOLTAGE REGULATORS

SX460 AVR - STANDARD

With this self excited control system the main stator suppliespower via the Automatic Voltage Regulator (AVR) to the exciterstator. The high efficiency semiconductors of the AVR ensurepositive build-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through a threephase full wave bridge rectifier. This rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit.

AS440 AVR

With this self-excited system the main stator provides power viathe AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial lowlevels of residual voltage.The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by asurge suppressor against surges caused, for example, by shortcircuit or out-of-phase paralleling.The AS440 will support a range of electronic accessories,including a 'droop' Current Transformer (CT) to permit paralleloperation with other ac generators.

MX341 AVR

This sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the main exciter,giving a source of constant excitation power independent ofgenerator output. The main exciter output is then fed to themain rotor, through a full wave bridge, protected by a surgesuppressor. The AVR has in-built protection against sustainedover-excitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds.An engine relief load acceptance feature can enable full load tobe applied to the generator in a single step.If three-phase sensing is required with the PMG system theMX321 AVR must be used.We recommend three-phase sensing for applications withgreatly unbalanced or highly non-linear loads.

MX321 AVR

The most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally, three-phase rmssensing, for improved regulation and performance.Over voltage protection is built-in and short circuit current leveladjustments is an optional facility.

WINDINGS & ELECTRICAL PERFORMANCE

All generator stators are wound to 2/3 pitch. This eliminatestriplen (3rd, 9th, 15th …) harmonics on the voltage waveformand is found to be the optimum design for trouble-free supplyof non-linear loads. The 2/3 pitch design avoids excessiveneutral currents sometimes seen with higher winding pitches,when in parallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. This winding,with the 2/3 pitch and carefully selected pole and toothdesigns, ensures very low waveform distortion.

TERMINALS & TERMINAL BOX

Standard generators are 3-phase reconnectable with 12 endsbrought out to the terminals, which are mounted on a cover atthe non-drive end of the generator. A sheet steel terminal boxcontains the AVR and provides ample space for thecustomers' wiring and gland arrangements. It has removablepanels for easy access.

SHAFT & KEYS

All generator rotors are dynamically balanced to better thanBS6861:Part 1 Grade 2.5 for minimum vibration in operation.

INSULATION/IMPREGNATION

The insulation system is class 'H'.All wound components are impregnated with materials andprocesses designed specifically to provide the high buildrequired for static windings and the high mechanical strengthrequired for rotating components.

QUALITY ASSURANCE

Generators are manufactured using production procedureshaving a quality assurance level to BS EN ISO 9001.

The stated voltage regulation may not be maintained in thepresence of certain radio transmitted signals. Any change inperformance will fall within the limits of Criteria 'B' of EN61000-6-2:2001. At no time will the steady-state voltageregulation exceed 2%.

DE RATES

All values tabulated on page 6 are subject to the followingreductions

5% when air inlet filters are fitted.3% for every 500 metres by which the operating altitudeexceeds 1000 metres above mean sea level.3% for every 5 C by which the operational ambienttemperature exceeds 40 C.

Note: Requirement for operating in an ambient exceeding60 C must be referred to the factory.

NB Continuous development of our products entitles us tochange specification details without notice, therefore theymust not be regarded as binding.

Front cover drawing typical of product range.

2

Page 26: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.

A.V.R. MX321 MX341

VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING

SUSTAINED SHORT CIRCUIT

CONTROL SYSTEM SELF EXCITED

A.V.R. SX460 AS440

VOLTAGE REGULATION ± 1.5 % ± 1.0 % With 4% ENGINE GOVERNING

SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT

INSULATION SYSTEM CLASS H

PROTECTION

RATED POWER FACTOR

STATOR WINDING

WINDING PITCH

WINDING LEADS

STATOR WDG. RESISTANCE

ROTOR WDG. RESISTANCE

EXCITER STATOR RESISTANCE

EXCITER ROTOR RESISTANCE

R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others

WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%

MAXIMUM OVERSPEED

BEARING DRIVE END

BEARING NON-DRIVE END

UCI274FWINDING 17

REFER TO SHORT CIRCUIT DECREMENT CURVES (page 5)

BALL. 6310-2RS (ISO)

IP23

0.8

1.52 Ohms at 22°C

0.038 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED

TWO THIRDS

12

20 Ohms at 22°C

0.091 Ohms PER PHASE AT 22°C

DOUBLE LAYER CONCENTRIC

2250 Rev/Min

BALL. 6315-2RS (ISO)

WEIGHT COMP. GENERATORWEIGHT WOUND STATORWEIGHT WOUND ROTORWR² INERTIASHIPPING WEIGHTS in a cratePACKING CRATE SIZETELEPHONE INTERFERENCECOOLING AIRVOLTAGE SERIES STARVOLTAGE PARALLEL STARVOLTAGE SERIES DELTA kVA BASE RATING FOR REACTANCE VALUESXd DIR. AXIS SYNCHRONOUSX'd DIR. AXIS TRANSIENTX''d DIR. AXIS SUBTRANSIENTXq QUAD. AXIS REACTANCEX''q QUAD. AXIS SUBTRANSIENTXL LEAKAGE REACTANCEX2 NEGATIVE SEQUENCEX0 ZERO SEQUENCE

REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATEDT'd TRANSIENT TIME CONST. 0.035sT''d SUB-TRANSTIME CONST. 0.011sT'do O.C. FIELD TIME CONST. 0.9sTa ARMATURE TIME CONST. 0.009sSHORT CIRCUIT RATIO 1/Xd

346V

206.3

2.170.18

0.140.08

0.121.300.170.07

600V300V

0.617 m³/sec 1308 cfm

1 BEARING 2 BEARING

200 kg

577 kg 123 x 67 x 103(cm)

563 kg

545 kg

THF<2% TIF<50

177.71 kg

1.5044 kgm2

188.67 kg

1.555 kgm2

( )

530 kg

123 x 67 x 103(cm)

200 kg

33

Page 27: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274FWinding 17

Locked Rotor Motor Starting CurvesSX

600V600V600V600V600V

0

5

10

15

20

25

30

0 100 200 300 400 500 600LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

.

SX

MX

600V600V600V600V600V

0

5

10

15

20

25

30

0 100 200 300 400 500 600LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

.

600V600V600V600V600V

0

5

10

15

20

25

30

0 100 200 300 400 500 600 700 800LOCKED ROTOR kVA

PER

CEN

T TR

AN

SIEN

T VO

LTA

GE

DIP

.

44

Page 28: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274FWinding 17

Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed

THREE PHASE EFFICIENCY CURVES

Based on star (wye) connection.

1000

10000

)

SYMMETRICAL

ASYMMETRICAL

3-phase 2-phase L-L 1-phase L-Nx 1.00 x 0.87 x 1.30x 1.00 x 1.80 x 3.20x 1.00 x 1.50 x 2.5010 sec. 5 sec. 2 sec.

SustainedMax. sustained duration

All other times are unchanged

InstantaneousMinimum

Sustained Short Circuit = 700 Amps

NoteThe following multiplication factor should be used to convert the values from curve for thevarious types of short circuit :

10

100

1000

10000

0.001 0.01 0.1 1 10TIME (secs)

CU

RR

ENT

(Am

ps)

SYMMETRICAL

ASYMMETRICAL

55

Page 29: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

Class - Temp Rise

Series Star (V)Parallel Star (V)Series Delta (V)

kVA

kW

Efficiency (%)

kW Input 183.6

346

218.8

175.0

92.5

189.2

346

212.5

170.0

92.6

150.0

92.9

161.4

346

206.3

165.0

92.7

178.1

DIMENSIONS

UCI274F

Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C

Winding 17 / 0.8 Power Factor

RATINGS

346

187.5

600300

600300

600300

600300

60Hz60Hz

66

Page 30: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

APPRO

VED D

OC

UM

ENT

UCI274F-17-TD-EN-SG-A

Head Office Address:Barnack Road, StamfordLincolnshire, PE9 2NB

United KingdomTel: +44 (0) 1780 484000Fax: +44 (0) 1780 484100

www.cumminsgeneratortechnologies.com

Copyright 2010, Cummins Generator Technologies Ltd, All Rights ReservedStamford and AvK are registered trade marks of Cummins Generator Technologies Ltd

Cummins and the Cummins logo are registered trade marks of Cummins Inc.

UCI274F-17-TD-EN-SG-A

Head Office Address:Barnack Road, StamfordLincolnshire, PE9 2NB

United KingdomTel: +44 (0) 1780 484000Fax: +44 (0) 1780 484100

www.cumminsgeneratortechnologies.com

Copyright 2010, Cummins Generator Technologies Ltd, All Rights ReservedStamford and AvK are registered trade marks of Cummins Generator Technologies Ltd

Cummins and the Cummins logo are registered trade marks of Cummins Inc.

Page 31: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

DSE7410/20AUTO START & AUTO MAINS FAILURE MODULES

DSEGenset

®

11ph2ph3phN

1ph2ph3phEN

1ph2ph3phN

1

11

232

6 4

MODEM

ISSUE 1

RS232 ANDRS485

CONFIGURABLEINPUTS

DC OUTPUTS ANALOGUESENDERS

EMERGENCY STOP

DC POWER SUPPLY 8-35V

DEUTZISUZUPERKINSCATERPILLARMTUVOLVOCUMMINSSCANIA

+D +W/L

GENERATOR SENSING

VOLTSVOLTS CURRENT

ELECTRONICENGINES &MAGNETIC PICK-UP

FUEL & CRANKOUTPUTSFLEXIBLE WITH CAN

CHARGEALTERNATOR

N/O VOLTFREE OUTPUT

N/C VOLT FREEOUTPUT

+

COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OFGEN-SET APPLICATIONS

7

OTHER

DSE7410/20

The DSE7410 is an Auto StartControl Module and the DSE7420is an Auto Mains (Utility) FailureControl Module suitable for a widevariety of single, diesel or gas, gen-set applications.

A sophisticated module monitoringan extensive number of engineparameters, the DSE74xx willannunciate warnings, shutdownand engine status information onthe back-lit LCD screen, illuminatedLED, remote PC, audible alarm andvia SMS text alerts. The moduleincludes RS232, RS485 & Ethernetports as well as dedicatedterminals for system expansion.

The DSE7400 Series modules arecompatible with electronic (CAN)and non-electronic (magnetic pick-up/alternator sensing) engines andoffer a comprehensive number offlexible inputs, outputs andextensive engine protections so thesystem can be easily adapted tomeet the most demanding industryparalleling requirements.

The modules can be easilyconfigured using the DSEConfiguration Suite Software.Selected front panel editing is alsoavailable.

FEATURES

ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITYBS EN 61000-6-2EMC Generic Immunity Standard for the Industrial EnvironmentBS EN 61000-6-4EMC Generic Emission Standard for the Industrial Environment

ELECTRICAL SAFETYBS EN 60950Safety of Information Technology Equipment, including Electrical Business Equipment

TEMPERATUREBS EN 60068-2-1Ab/Ae Cold Test -30 oCBS EN 60068-2-2Bb/Be Dry Heat +70 oC

VIBRATIONBS EN 60068-2-6Ten sweeps in each of three major axes5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn

HUMIDITYBS EN 60068-2-30Db Damp Heat Cyclic 20/55 oC@ 95% RH 48 HoursBS EN 60068-2-78Cab Damp Heat Static 40 oC@ 93% RH 48 Hours

SHOCKBS EN 60068-2-27Three shocks in each of three major axes15 gn in 11 mS

DEGREES OF PROTECTIONPROVIDED BY ENCLOSURESBS EN 60529IP65 - Front of module when installed into thecontrol panel with the supplied sealing gasket.

DSE2130DSE2131DSE2133DSE2152DSE2157DSE2548 485

MODBUS

USBPORT

USBHOST

ETHERNET

PC

DSENETEXPANSION

MAINS (UTILITY) SENSING (DSE7420)BUS SENSING (DSE7410)

Page 32: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

DEEP SEA ELECTRONICS PLC UKHighfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PHTELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303EMAIL [email protected] WEBSITE www.deepseaplc.com

DEEP SEA ELECTRONICS INC USA3230 Williams Avenue, Rockford, IL 61101-2668 USATELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708EMAIL [email protected] WEBSITE www.deepseausa.com

055-108/01/12 (1)

KEY FEATURES• Configurable inputs (11)• Configurable outputs (8)• Voltage measurement• Mains (utility) failure detection• Dedicated load test button• kW overload alarms• Comprehensive electrical

protection• RS232, RS485 & Ethernet

remote communications• Modbus RTU/TCP • PLC functionality• Multi event exercise timer • Back-lit LCD 4-line text display• Multiple display languages• Automatic start/Manual start• Audible alarm• Fixed and flexible LED indicators • Event log (250)• Engine protection• Fault condition notification to

a designated PC• Front panel mounting• Protected front panel

programming• Configurable alarms and timers• Configurable start and stop timers

• Five key menu navigation• Front panel editing with PIN

protection• 3 configurable maintenance

alarms• CAN and magnetic pick-up/Alt.

sensing• Fuel usage monitor and low fuel

alarms• Charge alternator failure alarm• Manual speed control (on

compatible CAN engines)• Manual fuel pump control • “Protections disabled” feature• Reverse power protection• Power monitoring (kW h, kV Ar,

kV A h, kV Ar h)• Load switching (load shedding

and dummy load outputs)• Automatic load transfer (DSE7420)• Unbalanced load protection• Independent earth fault trip• Fully configurable via DSE

Configuration Suite PC software• Configurable display languages• Remote SCADA monitoring via

DSE Configuration Suite PCsoftware

• Advanced SMS messaging(additional external modemrequired)

• Start & stop capability via SMSmessaging

• Additional display screens tohelp with modem diagnostics

• DSENet® expansion • Integral PLC editor

KEY BENEFITS• RS232, RS485 & Ethernet can

be used at the same time• DSENet® connection for

system expansion• PLC functionality• Five step dummy load support• Five step load shedding support• High number of inputs and

outputs• Worldwide language support• Direct USB connection to PC• Ethernet monitoring• USB host• Data logging & trending

RELATED MATERIALSTITLE PART NO’SDSE7410 Installation Instructions 053-085DSE7420 Installation Instructions 053-088DSE74xx Quick Start Guide 057-162DSE74xx Operator Manual 057-161DSE74xx PC Configuration Suite Manual 057-160

SPECIFICATION

DC SUPPLYCONTINUOUS VOLTAGE RATING8 V to 35 V Continuous

CRANKING DROPOUTSAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropoutand supply recovers to 5 V. This is achieved without the need for internal batteries

MAXIMUM OPERATING CURRENT260 mA at 12 V, 130 mA at 24 V

MAXIMUM STANDBY CURRENT120 mA at 12 V, 65 mA at 24 V

CHARGE FAIL/EXCITATION RANGE0 V to 35 V

OUTPUTSOUTPUT A (FUEL)15 A DC at supply voltage

OUTPUT B (START)15 A DC at supply voltage

OUTPUTS C & D8 A AC at 250 V AC (Volt free)

AUXILIARY OUTPUTS E,F,G,H,I & J2 A DC at supply voltage

GENERATOR VOLTAGE RANGE 15 V to 333 V AC (L-N)

FREQUENCY RANGE3.5 Hz to 75 Hz

MAINS (UTILITY) (DSE7420)VOLTAGE RANGE 15 V to 333 V AC (L-N)

FREQUENCY RANGE3.5 Hz to 75 Hz

BUS (DSE7410)VOLTAGE RANGE 15 V to 333 V AC (L-N)

FREQUENCY RANGE3.5 Hz to 75 Hz

MAGNETIC PICK UPVOLTAGE RANGE+/- 0.5 V to 70 V

FREQUENCY RANGE10,000 Hz (max)

DIMENSIONSOVERALL240 mm x 172 mm x 57 mm 9.4” x 6.8” x 2.2”

PANEL CUTOUT 220 mm x 160 mm 8.7” x 6.3”

MAXIMUM PANEL THICKNESS8 mm0.3”

STORAGE TEMPERATURE RANGE-40 oC to +85 oC

DSE7410/20AUTO START & AUTO MAINS FAILURE MODULES

®

DSEGenset

FEATURES

Registered in England & Wales No.01319649VAT No.316923457

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to changethe details shown on this data sheet without prior notice. The contents are intended for guidance only.

DSE7410

DSE7420

Page 33: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG23G0200TFFJNNNNNN

PRODUCT VIEW (Use Mouse to Rotate and Zoom)

Tech Data for Configured Product

Power Defense Catalog Number PDG23G0200TFFJNNNNNNFrame Size Frame 2Poles 3 PoleVoltage 480V ACInterruption or Breaking Capacity ( Icu/Ics) 35kAContinuous Current Rating (In) 200ATrip Unit Type TM Trip UnitTrip Unit Options 1 FixedTrip Unit Options 2 FixedIndicating Accessories NoneIndicating Accessories Terminal NoneTripping Accessories NoneTripping Accessory Terminal NoneTripping Accessory Voltage NoneLine Type Description Option 1 - Standard TerminalLine Conductor Options (1) 4 - 4/0Line Terminal Type AluminumLoad Type Description Option 1 - Standard TerminalLoad Conductor Options (1) 4 - 4/0Load Terminal Type AluminumSpecial Options - Type of Modification NoneDetails NoneAdditional Description None

PDF Datasheet Powered by CADENAS PARTsolutions

Eaton’s Power Defense™ molded case circuit breakers, a globally rated platform designed to help keep your power system safe with latest protection technology. Engineered for the future: IoT and Industry 4.0 features such as built-in communications, advanced energy metering, and algorithms that signal breaker maintenance; zone selective interlock technology that clears faults quickly and locally; ArcFlash reduction options that help protect your people, and not to mention Eaton’s best-inclass support and service.

Datasheet creation date: 13/11/2019 22:35

Page 34: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG23G0200TFFJNNNNNN

PDF Datasheet Powered by CADENAS PARTsolutions

Technical drawings

Datasheet creation date: 13/11/2019 22:35

Page 35: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG23G0200TFFJNNNNNN

PDF Datasheet Powered by CADENAS PARTsolutions

Datasheet creation date: 13/11/2019 22:35

General Technical Data

Frame Rating (In) 200AReference Standard UL489, CSA 22.2, IEC 60947-2 & GBNumber of poles 3Neutral rating -Interruption Rating Designator F / G / K / M / N / PUL Interruption Rating to UL 489 (240Vac) 35 / 65 / 85 / 100 / 150 / 200kAUL Interruption Rating to UL 489 (480Vac) 25 / 35 / 50 / 65(a) / 85 / 100kAUL Interruption Rating to UL 489 (600Vac) 14 / 18 / 22 / 25 / 30 / 35kAUL Interruption Rating to UL 489 (125/250Vdc) 10 / 10 / 10 / 22 / 22 / 22kAUL Current Limiting N / N / Y / Y / Y / YRated breaking capacity to IEC 60947-2 (220-240 Vac lcu) 35 / 55 / 85 / 100 / 150 / 200kARated breaking capacity to IEC 60947-2 (220-240 Vac lcs) 35 / 55 / 85 / 100 / 100 / 150kARated breaking capacity to IEC 60947-2 (380-415 Vac lcu) 25 / 36 / 50 / 70 / 70 / 100kARated breaking capacity to IEC 60947-2 (380-415 Vac lcs) 25 / 36 / 50 / 53 / 70 / 70kARated breaking capacity to IEC 60947-2 (440 Vac lcu) 25 / 30 / 35 / 50 / 70 / 100kARated breaking capacity to IEC 60947-2 (440 Vac lcs) 20 / 22.5 / 35 / 40 / 50 / 65kARated breaking capacity to IEC 60947-2 (525 Vac lcu)Rated breaking capacity to IEC 60947-2 (525 Vac lcs) 15 / 15 / 15 / 15 / 15 / 18kARated breaking capacity to IEC 60947-2 (690 Vac lcu) - / 8 / 10 / 10 / 10 / 10kARated breaking capacity to IEC 60947-2 (690 Vac lcs) - / 4 / 5 / 5 / 5 / 5kARated breaking capacity to IEC 60947-2 (125V DC lcu) 10 / 10 / 10 / 22 / 22 / 22kARated breaking capacity to IEC 60947-2 (250V DC 2P in series lcs) 10 / 10 / 10 / 22 / 22 / 22kAFrequency 50/60HzTrip Unit Type TM Trip UnitContinuous Current Range Fixed100% UL489 RatedInstantaneous/Short Circuit Range FixedMagnetic/Instantaneous Override 2000ADimensions H x W x D (inches) 6 x 4.12 x 3.50Pole to pole distance inches 1,375Approx Weight lbs 4RoHS Compliance YesUL File Number E7819Ambient Temp CalibrationDerating at 50CDerating at 60C 95%Derating at 70C 90%

1. 480Vac corresponds to 277Vac for 1P 2. 600Vac corresponds to 347Vac for 1P

Page 36: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0250B2NJNNNNNN

PRODUCT VIEW (Use Mouse to Rotate and Zoom)

Tech Data for Configured Product

Power Defense Catalog Number PDG33G0250B2NJNNNNNNFrame Size Frame 3Poles 3 PoleVoltage 480V ACInterruption or Breaking Capacity ( Icu/Ics) 35kAContinuous Current Rating (In) 250ATrip Unit Type PXR10Trip Unit Options 1 LSITrip Unit Options 2 NoneIndicating Accessories NoneIndicating Accessories Terminal NoneTripping Accessories NoneTripping Accessory Terminal NoneTripping Accessory Voltage NoneLine Type Description Option 1 - Standard TerminalLine Conductor Options (1) 250 - 500Line Terminal Type AluminumLoad Type Description Option 1 - Standard TerminalLoad Conductor Options (1) 250 - 500Load Terminal Type AluminumSpecial Options - Type of Modification NoneDetails NoneAdditional Description None

PDF Datasheet Powered by CADENAS PARTsolutions

Eaton’s Power Defense™ molded case circuit breakers, a globally rated platform designed to help keep your power system safe with latest protection technology. Engineered for the future: IoT and Industry 4.0 features such as built-in communications, advanced energy metering, and algorithms that signal breaker maintenance; zone selective interlock technology that clears faults quickly and locally; ArcFlash reduction options that help protect your people, and not to mention Eaton’s best-inclass support and service.

Datasheet creation date: 02/12/2019 17:27

Page 37: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0250B2NJNNNNNN

PDF Datasheet Powered by CADENAS PARTsolutions

Technical drawings

Datasheet creation date: 02/12/2019 17:27

Page 38: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0250B2NJNNNNNN

PDF Datasheet Powered by CADENAS PARTsolutions

Datasheet creation date: 02/12/2019 17:27

General Technical Data

Frame Rating (In) 250AReference Standard UL489, CSA 22.2, IEC 60947-2 & GBNumber of poles 3Neutral rating -Interruption Rating Designator F / G / K / M / N / PUL Interruption Rating to UL 489 (240Vac) 35 / 65 / 85 / 100 / 150 / 200kAUL Interruption Rating to UL 489 (480Vac) 25 / 35 / 50 / 65(a) / 85 / 100kAUL Interruption Rating to UL 489 (600Vac) 14 / 18 / 25 / 35 / 50 / 65kAUL Interruption Rating to UL 489 (125/250Vdc)UL Current Limiting N / N / N / Y / Y / YRated breaking capacity to IEC 60947-2 (220-240 Vac lcu) 35 / 55 / 85 / 100 / 150 / 200kARated breaking capacity to IEC 60947-2 (220-240 Vac lcs) 35 / 55 / 85 / 100 / 100 / 150kARated breaking capacity to IEC 60947-2 (380-415 Vac lcu) 25 / 36 / 50 / 70 / 70 / 100kARated breaking capacity to IEC 60947-2 (380-415 Vac lcs) 25 / 36 / 50 / 53 / 70 / 70kARated breaking capacity to IEC 60947-2 (440 Vac lcu) 25 / 30 / 35 / 50 / 70 / 100kARated breaking capacity to IEC 60947-2 (440 Vac lcs) 20 / 22.5 / 35 / 40 / 50 / 50kARated breaking capacity to IEC 60947-2 (525 Vac lcu) 18 / 20 / 25 / 30 / 35 / 40kARated breaking capacity to IEC 60947-2 (525 Vac lcs) 5 / 7.5 / 10 / 15 / 25 / 25kARated breaking capacity to IEC 60947-2 (690 Vac lcu) - / 8 / 10 / 15 / 20 / 20kARated breaking capacity to IEC 60947-2 (690 Vac lcs) - / 4 / 5 /7. 5 / 10 / 10kARated breaking capacity to IEC 60947-2 (125V DC lcu)Rated breaking capacity to IEC 60947-2 (250V DC 2P in series lcs) 10 / 10 / 10 / 22 / 22 / 22kAFrequency 50/60HzTrip Unit Type PXR10Continuous Current Range 90 - 250A100% UL489 Rated YesInstantaneous/Short Circuit Range 2 - 15 InMagnetic/Instantaneous Override 4400ADimensions H x W x D (inches) 10.125 x 5.47 x 4.297Pole to pole distance inches 1,719Approx Weight lbs 16RoHS Compliance YesUL File Number E7819Ambient Temp CalibrationDerating at 50CDerating at 60CDerating at 70C

1. 480Vac corresponds to 277Vac for 1P 2. 600Vac corresponds to 347Vac for 1P

Page 39: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0600B2NJNNNNNN

PRODUCT VIEW (Use Mouse to Rotate and Zoom)

Tech Data for Configured Product

Power Defense Catalog Number PDG33G0600B2NJNNNNNNFrame Size Frame 3Poles 3 PoleVoltage 480V ACInterruption or Breaking Capacity ( Icu/Ics) 35kAContinuous Current Rating (In) 600ATrip Unit Type PXR10Trip Unit Options 1 LSITrip Unit Options 2 NoneIndicating Accessories NoneIndicating Accessories Terminal NoneTripping Accessories NoneTripping Accessory Terminal NoneTripping Accessory Voltage NoneLine Type Description Option 1 - Standard TerminalLine Conductor Options (2) 2 - 500Line Terminal Type AluminumLoad Type Description Option 1 - Standard TerminalLoad Conductor Options (2) 2 - 500Load Terminal Type AluminumSpecial Options - Type of Modification NoneDetails NoneAdditional Description None

PDF Datasheet Powered by CADENAS PARTsolutions

Eaton’s Power Defense™ molded case circuit breakers, a globally rated platform designed to help keep your power system safe with latest protection technology. Engineered for the future: IoT and Industry 4.0 features such as built-in communications, advanced energy metering, and algorithms that signal breaker maintenance; zone selective interlock technology that clears faults quickly and locally; ArcFlash reduction options that help protect your people, and not to mention Eaton’s best-inclass support and service.

Datasheet creation date: 02/12/2019 17:40

Page 40: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0600B2NJNNNNNN

PDF Datasheet Powered by CADENAS PARTsolutions

Technical drawings

Datasheet creation date: 02/12/2019 17:40

Page 41: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG33G0600B2NJNNNNNN

PDF Datasheet Powered by CADENAS PARTsolutions

Datasheet creation date: 02/12/2019 17:40

General Technical Data

Frame Rating (In) 600AReference Standard UL489, CSA 22.2, IEC 60947-2 & GBNumber of poles 3Neutral rating -Interruption Rating Designator F / G / K / M / N / PUL Interruption Rating to UL 489 (240Vac) 35 / 65 / 85 / 100 / 150 / 200kAUL Interruption Rating to UL 489 (480Vac) 25 / 35 / 50 / 65(a) / 85 / 100kAUL Interruption Rating to UL 489 (600Vac) 14 / 18 / 25 / 35 / 50 / 65kAUL Interruption Rating to UL 489 (125/250Vdc)UL Current Limiting N / N / N / N / Y / YRated breaking capacity to IEC 60947-2 (220-240 Vac lcu) 35 / 55 / 85 / 100 / 150 / 200kARated breaking capacity to IEC 60947-2 (220-240 Vac lcs) 35 / 55 / 85 / 100 / 100 / 150kARated breaking capacity to IEC 60947-2 (380-415 Vac lcu) 25 / 36 / 50 / 70 / 70 / 100kARated breaking capacity to IEC 60947-2 (380-415 Vac lcs) 25 / 36 / 50 / 53 / 70 / 70kARated breaking capacity to IEC 60947-2 (440 Vac lcu) 25 / 30 / 35 / 50 / 70 / 100kARated breaking capacity to IEC 60947-2 (440 Vac lcs) 20 / 22.5 / 35 / 40 / 50 / 50kARated breaking capacity to IEC 60947-2 (525 Vac lcu) 18 / 20 / 25 / 30 / 35 / 40kARated breaking capacity to IEC 60947-2 (525 Vac lcs) 5 / 7.5 / 10 / 15 / 25 / 25kARated breaking capacity to IEC 60947-2 (690 Vac lcu) - / 8 / 10 / 15 / 20 / 20kARated breaking capacity to IEC 60947-2 (690 Vac lcs) - / 4 / 5 /7. 5 / 10 / 10kARated breaking capacity to IEC 60947-2 (125V DC lcu)Rated breaking capacity to IEC 60947-2 (250V DC 2P in series lcs) 10 / 10 / 10 / 22 / 22 / 22kAFrequency 50/60HzTrip Unit Type PXR10Continuous Current Range 250 - 600A100% UL489 Rated YesInstantaneous/Short Circuit Range 2 - 10 InMagnetic/Instantaneous Override 7200ADimensions H x W x D (inches) 10.125 x 5.47 x 4.297Pole to pole distance inches 1,719Approx Weight lbs 16RoHS Compliance YesUL File Number E7819Ambient Temp CalibrationDerating at 50CDerating at 60CDerating at 70C

1. 480Vac corresponds to 277Vac for 1P 2. 600Vac corresponds to 347Vac for 1P

Page 42: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG43G0800B2NJNNNNNN

PRODUCT VIEW (Use Mouse to Rotate and Zoom)

Tech Data for Configured Product

Power Defense Catalog Number PDG43G0800B2NJNNNNNNFrame Size Frame 4Poles 3 PoleVoltage 240V ACInterruption or Breaking Capacity ( Icu/Ics) 55kAContinuous Current Rating (In) 800ATrip Unit Type PXR10Trip Unit Options 1 LSITrip Unit Options 2 NoneIndicating Accessories NoneIndicating Accessories Terminal NoneTripping Accessories NoneTripping Accessory Terminal NoneTripping Accessory Voltage NoneLine Type Description Option 1 - Standard TerminalLine Conductor Options (3) 3/0 - 400Line Terminal Type AluminumLoad Type Description Option 1 - Standard TerminalLoad Conductor Options (3) 3/0 - 400Load Terminal Type AluminumSpecial Options - Type of Modification NoneDetails NoneAdditional Description None

PDF Datasheet Powered by CADENAS PARTsolutions

Eaton’s Power Defense™ molded case circuit breakers, a globally rated platform designed to help keep your power system safe with latest protection technology. Engineered for the future: IoT and Industry 4.0 features such as built-in communications, advanced energy metering, and algorithms that signal breaker maintenance; zone selective interlock technology that clears faults quickly and locally; ArcFlash reduction options that help protect your people, and not to mention Eaton’s best-inclass support and service.

Datasheet creation date: 20/11/2019 22:02

Page 43: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG43G0800B2NJNNNNNN

PDF Datasheet Powered by CADENAS PARTsolutions

Technical drawings

Datasheet creation date: 20/11/2019 22:02

Page 44: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Molded Case Circuit BreakersPower Defense ™ UL Global SeriesPart Number: PDG43G0800B2NJNNNNNN

PDF Datasheet Powered by CADENAS PARTsolutions

Datasheet creation date: 20/11/2019 22:02

General Technical Data

Frame Rating (In) 800AReference Standard UL489, CSA 22.2, IEC 60947-2 & GBNumber of poles 3Neutral rating -Interruption Rating Designator G / K / MUL Interruption Rating to UL 489 (240Vac) 65 / 85 / 100kAUL Interruption Rating to UL 489 (480Vac) 35 / 50 / 65(a)kAUL Interruption Rating to UL 489 (600Vac) 18 / 25 / 35kAUL Interruption Rating to UL 489 (125/250Vdc)UL Current Limiting -Rated breaking capacity to IEC 60947-2 (220-240 Vac lcu) 55 / 85 / 100 / 100kARated breaking capacity to IEC 60947-2 (220-240 Vac lcs) 55 / 85 / 100 / 100kARated breaking capacity to IEC 60947-2 (380-415 Vac lcu) 36 / 50 / 70 / 70kARated breaking capacity to IEC 60947-2 (380-415 Vac lcs) 36 / 50 / 53 / 70kARated breaking capacity to IEC 60947-2 (440 Vac lcu) 30 / 35 / 50 / 65kARated breaking capacity to IEC 60947-2 (440 Vac lcs) 22.5 / 35 / 40 / 50kARated breaking capacity to IEC 60947-2 (525 Vac lcu) 20 / 25 / 30 / 35kARated breaking capacity to IEC 60947-2 (525 Vac lcs) 16.5 / 20 / 25 / 25kARated breaking capacity to IEC 60947-2 (690 Vac lcu) 8 / 10 / 15 / 20kARated breaking capacity to IEC 60947-2 (690 Vac lcs) 4 / 5 /7. 5 / 10kARated breaking capacity to IEC 60947-2 (125V DC lcu)Rated breaking capacity to IEC 60947-2 (250V DC 2P in series lcs) 22 / 22 / 25kAFrequency 50/60HzTrip Unit Type PXR10Continuous Current Range 320 - 800A100% UL489 Rated YesInstantaneous/Short Circuit Range 2 - 8 InMagnetic/Instantaneous Override 6800ADimensions H x W x D (inches) 16 x 8.25 x 4.38Pole to pole distance inches 2,75Approx Weight lbs 29,98RoHS Compliance YesUL File Number E7819Ambient Temp CalibrationDerating at 50CDerating at 60CDerating at 70C

1. 480Vac corresponds to 277Vac for 1P 2. 600Vac corresponds to 347Vac for 1P

Page 45: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

Phone: 800-767-8541 • Fax: 707-226-9670 • www.guestindustrial.com12

Genset Chargers

2

5

6

10

1

1

1

2

2

5

6

5/5

12V

24V

12V

12V+12V

100 - 13050/60Hz

100 - 13050/60Hz

100 - 13050/60Hz

100 - 13050/60Hz

6' w/ Connect-

Charge plug

6' SJT 18-3w/ Connect- Charge plug

6' cable w/molded plugrated -40 to 105C

Studs

4' w/ ring terminals

6' SJT 18-3w/ ring

terminals

4' w/ ring terminals

rated -40 to 105C

Studs

2.9" x 5.1" x 1.5"

7.4" x 6.3" x 2.4"

3.5" x 6.4" x 2.3"

5.5" x 7.8" x 2.4"

UL

UL

UL

UL

2

4.5

4

5.6

2602A-12

2602A-12-B (bulk)

2605A-1-24RT-01(bulk pack only) (1)

2608A-B-01 (bulk pack only) (1)

2610A

2610A-B (bulk)

MODEL TOTALAMPS

OUT-PUTS

AMPS PEROUTPUT

BATTERYSYSTEM

INPUTVOLTAGE AC DC DIMENSIONS AGENCY

LISTINGWT.

(LBS)

(bulk only)

Genset Chargers

Guest chargers are proven performers in genset applications.For specific application information, or if you are developing a newproduct, be sure to consult with the Guest applications engineeringteam to ensure the correct charger is specified.

2602A-12

2610A

2608A-B-01

Individual agency listings as shown in product chart.(1) 2-stage charging

Page 46: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

14

Page 47: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc

BERGARI

SOLUTIO

NS

mem

ber of the m

and

ersgroup

09/15/2017O

VERA

LL HEIG

HT C

HA

NG

EC

B

INFO

RMA

TION

±1°

.XXXX = ±0.03125.XXX = ±0.0625.XX = ±0.125.X = ±0.25

ALL A

NG

LESO

THERWISE SPEC

IFIED

ENGINEERING

DRAW

N BY

CHEC

KED BY

MA

NUFAC

TURING

02

TOLERA

NC

ES DO

NO

T APPLY TO

TOLERA

NC

ES UNLESS

REVEC

OD

ESCRIPTIO

NC

OM

MERC

IAL FEA

TURES

permission from

Bergari Solutions, LLC.

DESCRIPTIO

N

DATE

DATE

DATE

GA

GE TH

ICKN

ESS OR

copied or shared in any form w

ithout the express

DATE

ENG

INE

INFO

RMA

TION

RESON

ATO

R ALPHA

SILENC

ER Km

ENG

INE M

AKE

ENG

INE M

ODEL

DISPLAC

EMEN

T

EXHAUST FLO

W

EXHAUST TEM

PERATURE

MA

X BAC

K PRESSURE

RAW

SOUN

D PRESSURE

CO

NSTRUC

TION

MA

TERIAL

FINISH

PART N

UMBER

WEIG

HT (LBS)59

SHEET SIZE

THIRD A

NG

LE PROJEC

TION

RESON

ATO

R FREQUEN

CY

SCA

LE (DO N

OT SC

ALE)

A

1

BCD

23

45

67

8

PSI

5.7L

537

1063

1300

---

---------

1:7B

CS

HIG

H TEM

P BLAC

K PAIN

T

500-00834602

CB

3.50-3.50 Ø14.00

SIL: CO

MP C

RIT CS S-E

CB

CB

CB

09/15/2017

CUSTO

MER

CUSTO

MER P/N

------

SILENC

ER IL

SHEET3 OF 3

---

40

26.00 OA

L F:5.50 ---

07/13/2017

REV.

BYD

ATE

This drawing and the inform

ation contained is confidential and the property of Bergari

Solutions, LLC. N

one of this information is to be

SILENC

ER

---

12.00

3.50 OD

10.00

19.07

3.63 OD

SLOTTED

CUFF

10.00

14.00N

OM

0.50-14.00 NPT D

RAIN

5.50

20.50

26.00 22.00

3.00TYP

D

TYPTYP

4.00

3.00

8.00

3.00

11.00

DETA

IL DSC

ALE 2 : 7

0.75

TYP TYP

0.50TYP

1.05

1.00TYP

Page 48: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc
Page 49: 60 HZ MODEL SPJD-1550 - Gillette Generators, Inc