25
1 18/03/2004 ECONOMIE D’ENERGIE UNE SOURCE ADAPTEE A L’APPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

Embed Size (px)

Citation preview

Page 1: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

1 18/03/2004

ECONOMIE D’ENERGIE

UNE SOURCE ADAPTEE A L’APPLICATION

UN LUMINAIRE JUDICIEUSEMENT CHOISI

Page 2: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

2 18/03/2004

RENDEMENT (lm/W) IRC TEMPERATURE(°K) DUREE VIE (h)

INCAND 10 100 2700 1000

HALOGENE 20 100 3000 3000

TUBES 79/90 85 2700/6000 12000

FLUO COMPACTE 70 85 2700/4000 10000

SHP 125 25 1950 20000

IODURES METALIQUES 85 85 3000/4000 12000

LAMPES A FILAMENT

LAMPES FLUORESCENTES

LAMPES A DECHARGE

PERFORMANCE DES SOURCES

Page 3: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

3 18/03/2004

•DES RENDEMENTS TRES DIFFERENTS SELON LES APPAREILS

•DES LUMINAIRES DIFFERENTS SELON LES APPLICATIONS

Page 4: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

4 18/03/2004

LA DUREE DE VIE DES SOURCES

•LES DIFFERENTES DUREE DE VIE

•L’INFLUENCE DE L’ALIMENTATION

Page 5: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

5 18/03/2004

•DUREE DE VIE INDIVIDUELLE

•DUREE DE VIE MOYENNE

•DUREE DE VIE ECONOMIQUE

•MORTALITE

Page 6: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

6 18/03/2004

DUREE DE VIE MOYENNE (h)

DUREE DE VIE ECONOMIQUE (h)

CYCLE 2h45+15' TFP CU 15000 12000TFP HF-B 13000 10000TFP HF-P 20000 17000BI 15000 7500

TUBES FLUORESCENTS

Page 7: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

7 18/03/2004

•ALIMENTATION FERRO-MAGNETIQUE

•BALLAST HF-B

•BALLAST HF-P

•BALLAST HF-R

Page 8: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

8 18/03/2004

INFLUENCE DE L’ALIMENTATION SELON CYCLE D’ALLUMAGE

CYCLE CU + starter HF-P HF-B11h30+30' 17000 23000 190002h45+15' 14000 20000 130000h50'+10' 11000 16000 7000

DUREE DE VIE MOYENNE

Page 9: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

9 18/03/2004

GESTION DE L’ECLAIRAGE

•CYCLE DE VIE DU BATIMENT•GESTION LOCALE•GESTION DU BATIMENT•DALI•L’INDUSTRIE

Page 10: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

10 18/03/2004

CYCLES DE VIE COMPOSANTSDU BATIMENT

CLOS ET COUVERT 50 ANS

INSTALLATIONS PRIMAIRESENERGIE, EAU , ELECTRICITE etc EC

LAIR

AG

E

20 ANS

INSTALLATIONS SECONDAIRESTELEPHONE , STORES etc

10 ANS

INFORMATIQUE TERMINAUX 5 ANS

POSTE DE TRAVAIL AMENAGEMENT 2 ANSDG / CPE

Page 11: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

11 18/03/2004

BALLASTS HF BALLASTS HF

BALLASTS HF

BALLASTS HF

BALLASTS HF

GESTION CENTRALISE

E

+

+

+

+GESTION

CENTRALISEE

GESTION CENTRALISE

E

GESTION CENTRALISE

E

COMMANDE LOCALE IR

COMMANDE LOCALE IR

COMMANDE LOCALE IR

CONTRÔLE LUMIERE DU JOUR

CONTRÔLE LUMIERE DU JOUR

DETCTION PRESENCE

+

+

+

+

++

14 kw.h / m2 / an

16 kw.h / m2 / an

20 kw.h / m2 / an

22 kw.h / m2 / an

30 kw.h / m2 / an

40 kw.h / m2 / an

LAMPES FLUO

BALLASTS Fe / Cu

15 W / m2

2700 H par AN

+

+

+

BILAN ENERGETIQUE

DG / CPE

Page 12: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

12 18/03/2004

COUT DE L’ECLAIRAGE DANS UN BATIMENT DE

BUREAUX

INVESTISSEMENT

ENERGIEDEPLACEMENT

CLOISONSMAINTENANCE

LUMINAIRES

+

INSTALLATION

+

CABLAGE

kW.H

0.60F

LAMPES

+

M.O.

CABLAGE

ELECRIQUE

42 € / m2 3.7 €/ m2 / An

1.6 €/ m2 / An

6.5 €/ m2 / An

Page 13: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

13 18/03/2004

TEMPS DE RETOUR

INSTALLATION

CLASSIQUE

ECLAIRAGE

INTELLIGENT

INVESTISSEMENT F /m2 42 € / m2 46 à 84 € / m2

ENERGIE F / m2 / AN 3.7 € - 1 à - 2.3 €

RELAMPING F / m2 / AN

RECONFIGURATION F / m2 /AN

TEMPS DE RETOUR

1.6 €

6.5 €

- 0.5 à - 1 €

-6.5 €

1 à 4 ANS

DG / CPE /

Page 14: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

14 18/03/2004

GESTION LOCALE : OCCUSWITCH

Page 15: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

15 18/03/2004

GESTION LOCALE : SCENARIO

Page 16: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

16 18/03/2004

FONCTIONS DE GESTION DE L’ECLAIRAGE

• ALLUMAGE / EXTINCTION• GRADATION/MEMORISATION• REGULATION EN FONCTION DES APPORTS

DE LUMIERE NATURELLE• AUTOMATISMES LIES A L ‘ OCCUPATION

DES LOCAUX• PROGRAMMATION TEMPORELLE• ASSERVISSEMNENT A D‘AUTRES

FONCTIONS DU BATIMENTDG / CPE

Page 17: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

17 18/03/2004

LCU 5315

LRC 5040

LRC 5225

secteur 230v

230v

115

0VA

CO

NT

LE

1/1

0v

100

balla

sts

secteur 220v

LRI 8133

CAPTEUR

IRT 8050

TELECOMMANDE IR

bus alimentation bus

1 P

AR

ZO

NE

Marketing HA

horloge

contrôleur

PC

SYSTEME HELIO

UNILON LOGICIEL GRAPHIQUE DE CONFIGURATION

Page 18: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

18 18/03/2004

Digital Adressable Lighting Interface

Une interface en entrée du ballast pour graduer et commuter la source

Communication numérique bi-directionnelle

•Informations vers le ballastcommande allumage / extinctionvaleur de gradation

•Informations provenant du ballastétat de la lampe et du ballast

DALI

BALLAST INTELLIGENT…...

Page 19: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

19 18/03/2004

Câblage 1-10V

9 Contrôleurs230v

Page 20: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

20 18/03/2004

Câblage DALI

1 Contrôleur230v

230v

DALI

Page 21: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

21 18/03/2004

COMPARAISON TRIOS DALI TRIOS 1-10V

TRIOS

LRC120

230 V

230 V

230 V

230 V

Capteurs

Circuit 1

Circuit 2

Circuit 3

TRIOS

LRC1020

230 V

TRIOS

LRC1020

230 V

Page 22: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

22 18/03/2004

TRIOS DALI -1

TRIOS

DALI

LRC1620

230 V

230 V

230 V

230 V

Capteurs

Circuit 1

Circuit 2

Circuit 3

Page 23: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

23 18/03/2004

TRIOS DALI-2

TRIOS

DALI

LRC1620

230 V

230 V

230 V

230 V

Capteurs

Circuit 1

Circuit 2

Circuit 3

Modification du nombre de ballast de chaque circuit : PAR PROGAMMATION

Page 24: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

24 18/03/2004

COMPARAISON TRIOS DALI TRIOS 1-10V

TRIOS

LRC120

230 V

230 V

230 V

230 V

Capteurs

Circuit 1

Circuit 2

Circuit 3

TRIOS

LRC1020

230 V

TRIOS

LRC1020

230 V

Modification du nombre de ballast de chaque circuit = changement du câblage

Page 25: 1 18/03/2004 ECONOMIE DENERGIE UNE SOURCE ADAPTEE A LAPPLICATION UN LUMINAIRE JUDICIEUSEMENT CHOISI

25 18/03/2004

Controleurs DALIO

Bus LON

Trois types de contrôles possible

Contrôle centralisé: DALI + LON