View
2
Download
0
Category
Preview:
Citation preview
Perma-Column® combines the durability of concrete with the value of post-frame construction for a long-lasting foundation performance.
Build better, build stronger, build to last.
Perma-Column® is 3x stronger than standard concrete
Supports solid posts, nail-laminated or glue-laminated wood columns
10,000 psi precast concrete
60,000 psi rebar
Powder-coated ¼” steel bracket
Uplift anchors and 12” and 24” column extenders available
Guaranteed to last generations
The International Code Council has evaluated and certified Perma-Column® precast concrete posts are compliant with the following:
• 2018 and 2015 International Building Code® (IBC)• 2018 and 2015 International Residential Code® (IRC)• 2017 Florida Building Code—Building• 2017 Florida Building Code—Residential• 2016 California Building Code (CBC)• 2016 California Residential Code (CRC)
• Easier permitting and approvals• Assured code-compliance
• Trust in Perma-Column® quality• Confidence in their lasting investment See ICC-ES Evaluation Report No. ESR-4238 at icc-es.org/report-listing/esr-4238/
Builder advantages
Customer benefits
CERTIFIED EXCELLENCEICC-ES certified
The Perma-Column® difference
LOAD AND RESISTANCE FACTOR DESIGN (LRFD)
PLRFD (lb)
PC6300 PC6400 PC6600 PC8300 PC8400 PC8500
VLRFD-x
(lb)VLRFD-z
(lb)VLRFD-x
(lb)VLRFD-z
(lb)VLRFD-x
(lb)VLRFD-z
(lb)VLRFD-x
(lb)VLRFD-z
(lb)VLRFD-x
(lb)VLRFD-z
(lb)VLRFD-x
(lb)VLRFD-z
(lb)
1000090008000
372236683614
370636523598
461045554501
497749184860
431442604205
455644984441
512150635004
464045874534
638663276269
630562476190
759275337475
787878177756
700060005000
355935053451
354434903436
444743924338
480147424684
415140974042
438443264269
494648874828
448144284375
621061516093
613260746016
741673577299
769576347573
400030002000
339733423288
338233283274
428442294175
462545664507
398839343879
421241544097
477047114653
432142684215
603459765917
595859005843
724071817123
751374527391
10000
-1000-2000
3234318029632746
3220316629502734
4120406638493631
4449439041553921
3825377135533336
4039398237533523
4594453543014067
4162410938973684
5858580055665331
5785572754955264
7064700567716536
7330726970266782
-3000-4000-5000
252823112094
251823022086
341431962979
368634513216
311929012684
329430642835
383235983363
347232603047
509748624628
503348014570
630160675832
653962956051
BUILD BETTER. BUILD STRONGER. BUILD TO LAST.
SHEAR CAPACITIES
LOAD AND RESISTANCE FACTOR DESIGN (LRFD) ALLOWABLE STRENGTH DESIGN (ASD)
Model ID
Width (in)
Depth (in)
Length (in)
PLRFD (lb)
MLRFD-x
(ft-lb)MLRFD-z (ft-lb)
TLRFD (lb)
PASD (lb)
MASD-x (ft-lb)
MASD-z (ft-lb)
TASD (lb)
PC6300 5-3/8 5-3/8 59-3/4 113100 6517 6620 10320 70700 4073 4137 6870
PC6400 6-7/8 5-3/8 59-3/4 140100 9217 6723 9070 87600 5761 4202 6030
PC6600 6-3/8 5-3/8 59-3/4 131100 8317 6694 9360 82000 5198 4184 6230
PC8300 5-3/8 7-1/8 59-3/4 153100 9781 14545 15710 95700 6113 9091 10450
PC8400 6-7/8 7-1/8 59-3/4 188900 13966 14792 13590 118100 8729 9245 9040
PC8500 8-3/8 7-1/8 59-3/4 223000 17955 14945 12340 139400 11222 9341 8210
Perma-Column® meets the market demand for durability, fits into your current building process, and elevates your reputation for enduring quality.
For SI: 1 inch = 25.4 mm, 1 pound = 4.4482 N 1 For biaxial bending: mx + mz < 1 Mx Mz 2 The tabulated values account for combined axial compression load and bending moment load. No reduction in
axial compression loads and bending moment loads for combined axial compression bending moment is required. 3 For combined tension loads and bending moment loads: t + m < 1 T M4 Length is measured from the top of the concrete to the bottom of the concrete.
For SI: 1 inch = 25.4 mm, 1 pound = 4.4482 N 1 The tabulated shear values are for columns with axial tension load (ACI 318-14 Eq. 22.5.6.1 and 22.5.7.1 respectively)
ALLOWABLE STRENGTH DESIGN (ASD)
PASD (lb)
PC6300 PC6400 PC6600 PC8300 PC8400 PC8500
VASD-x
(lb)VASD-z (lb)
VASD-x
(lb)VASD-z (lb)
VASD-x
(lb)VASD-z (lb)
VASD-x
(lb)VASD-z (lb)
VASD-x
(lb)VASD-z (lb)
VASD-x
(lb)VASD-z (lb)
625056255000
232622922259
231622832249
288128472813
311130743037
269626622628
284728122776
320131643128
290028672834
399139543918
394139053869
474547084672
492448864848
437537503125
222521912157
221521812148
277927452711
300129642927
259425602526
274027042668
309130543018
280027672734
388138453808
383237963760
463545984562
481047714733
250018751250
212320892055
211420802046
267726432609
289128542817
249224582425
263225962561
298129442908
270126682635
377137353698
372436883652
452544884452
469546574619
6250
-625-1250
2021198718521716
2013197918441709
2575254124052270
2780274425972450
2391235722212085
2525248923452202
2871283526882542
2601256824352303
3662362534783332
3615357934353290
4415437842324085
4581454343914239
-1875-2500-3125
158014451309
157414391303
213419981862
230421572010
194918131677
205819151772
239522492102
217020371905
318630392893
314530012856
393837923645
408739343782
© 2020 Perma-Column, LLC All rights reserved.
BUILD BETTER Perma-Column® outperforms treated wood — guaranteed
Insist on the environmentally friendly solution that will outlast a treated wood foundation every time. Only Perma-Column® precast concrete columns provide your building a foundation engineered to last for generations to come.
BUILD STRONGER Perma-Column® is 3x stronger than concrete
Perma-Column® piers are precast concrete, reinforced with 60,000 psi rebar welded to a ¼” steel bracket. Perma-Column® is the unmatched post-frame foundation solution for homes and municipal, commercial, and agricultural buildings.
BUILD TO LAST Perma-Column® protects the value of your building
Post-frame construction materials have come a long way. Your building deserves the lasting durability of a permanent foundation. Perma-Column® is engineered to protect the structural integrity of your post-frame building and is backed by a lifetime warranty.
www.permacolumn.com
400 Carol Ann Lane, Ossian, IN 46777 | Tel: 800 622-7190 | Fax: 260 622-7192
BUILD ON A PERMANENT FOUNDATION Build with Perma-Column®
Recommended