DERVATIZATION AND APPLICATION OF HPLC

DEPARTMENT OF PHARMACEUTICAL CHEMISTRY

MCOPS

SUBMITTED TO SUBMITTED BYDr Suvarna G. kini Shikha Tyagi Associate. Professor 100602017

Page 2: Hplc final

High-performance liquid chromatography (or high-pressure liquid chromatography, HPLC) is a chromatographic technique that can separate a mixture of compounds and is used in biochemistry and analytical chemistry to identify, quantify and purify the individual components of the mixture.

High performance liquid chromatography is basically a highly improved form of column chromatography.

Instead of a solvent being allowed to drip through a column under gravity, it is forced through under high pressures of up to 400 atmospheres.

That makes it much faster.

smaller particle size for the column packing material which gives a much greater surface area for interactions between the stationary phase and the molecules flowing past it.

This allows a much better separation of the components of the mixture.

Page 3: Hplc final

SCHEMATIC REPRESENTATION OF HPLC

Page 4: Hplc final

LISTS OF STEPS NEEDED BEFORE ANYONE RUNS HPLC

Filter the solvents with membranes with 0.22-0.45 mm

Use clean and transparent reservoirs through which precipitates and colloids can be distinguished.

Make sure that the solvents will be easily mixed with the previous solvents in the same inlets . For example methanol or water should not be placed instead of hexane directly, or any organic solvent should not be placed directly instead of a buffer reservoir.

Degass the solvents and purge all the tubing that lead to the pump.

Connect the column carefully according to the flow direction marked on it (do not connect directly to the detector).

Flow the appropriate solvents through the column at a low flow-rate (0.1-0.5 ml/min) or reach the composition gradually using the appropriate gradient.

Select the appropriate wavelength (or other type of setting) in the detector and wait for stable baseline .

.

Page 5: Hplc final

Prepare the set of methods in the workstation

Processing method for the data processing and the Report method for the report of final results.

When the system and the methods are ready a blank run should be performed to test the system and verify that it is clean from interferences

Page 6: Hplc final

DERIVATIZATION

Derivatization is a technique used in chemistry which transforms a chemical compound into a product (the reaction's derivate) of similar chemical structurecalled a derivative.

Generally, a specific functional group of the compound participates in the derivatization reaction and transforms the it to a derivate of deviating reactivity, solubility, boiling point melting point,aggregate state, or chemical composition.

Resulting new chemical properties can be used for quantification or  separation of thecompound

Page 7: Hplc final

RATIONALE BEHIND DERIVATIZATION In liquid chromatography, fluorescent derivatives can be prepared to render the substances specifically detectable at high sensitivity.

To prepare fluorescent derivatives of phenols, and primary and secondary amines, dansyl chloride (5-dimethyl aminonaphthalene-1-sulphonyl chloride) is strongly recommended

To render involatile substances volatile for GC analysis, organic acids can be esterified using boron trifluoride as a catalyst or directly with diazomethane.

the polarity of a solute needs to be drastically reduced to improve its chromatographic behavior and reduce tailing. Polarity reduction can often be achieved for amino, hydroxyl and thiol groups by acylation.

In LC analyses, UV chromaphores and fluorophores are often introduced into sample molecules to increase their sensitivity to UV absorption and fluorescence detection. Benzoyl chloride, m-toluol chloride and p-nitrobenzoyl chloride are reagents that can add a benzene ring to a solute molecule and render it UV absorbing.

Page 8: Hplc final

SEVERAL CHARACTERISTICS ARE DESIRABLE FOR A DERIVATIZATION REACTION

The reaction is reliable and proceeds to completion.

Less unreacted starting material will simplify analysis.

Also, this allows a small amount of analyte to be used.

The reaction is general, allowing a wide range of substrates,

yet specific to a single functional group,

reducing complicating interference.

The products are relatively stable, and form no degradation

products within a reasonable period, facilitating analysis.

Page 9: Hplc final

DERIVATIZATION TYPES

Pre column

Post column

Page 10: Hplc final

PRE-COLUMN OFF-LINE DERIVATIZATION

When there is a mixture of many componds they may interfere in the separation and resolution in such case we can derivatize the compound of interest to change its properties so that it can be separated .

Merits :

(a) Requires no modification to the instrument i.e., a plus point when compared to the post-column methods

(b) Imposes fewer limitations with regard to reaction-time and conditions.

Demerits

(b) Formation of a stable and well-defined product is an absolute necessity.

(b) Presence of excess reagent or by products may invariably interfere with separation.

(c) Very often derivatization may altogether change the chromatographic properties of the sample which facilitated separation.

Page 11: Hplc final

Nineteen amino acids in a standard mixture were separated using a GROM-SIL OPA-1 column after precolumn derivatization with OPA /mercaptopropionic acid and detected by fluorescence spectroscopy at 330 and 450nm.

Nineteen amino acids in a standard mixture were separated using a GROM-SIL OPA-1 column (150 x 4mm, Part No. GSOP10308S1504) after precolumn derivatization with OPA/mercaptopropionic acid by gradient elution with

25mM sodium phosphate, pH 7.2 and THF 995/5

25mM sodium phosphate, pH 7.2, methanol and acetonitrile 50/35/15

Time - 41 minutes

Detection - Fluorescence spectroscopy at 330 and 450nm.

The amino acids separated were aspartic acid, glutamic acid, asparagine, serine, glutamine, glycine, threonine, histidine, citrulline, 3-methylhistidine, alanine, taurine, arginine, alpha-aminobutyric acid, tyrosine, valine, methionine, nor-valine and tryptophan.

Page 12: Hplc final

POST-COLUMN ON-LINE DERIVATIZATION

The following experimental parameters should be maintained

(a) Derivatization performed in a special-reactor strategically positioned between the column and the detector.

(b) Reaction must be completed rapidly at moderate temperatures.

(c) Derivatization reaction need not even go to completion provided it can be made reproducible.

(d) No detector-response should exist due to any excess reagent present.

(e) Reaction must be carried out in a medium other than the mobile-phase.

Merit : The main merit of post-column-on-line derivatization is that ideally the separation and detection processes can be optimized individually

Page 13: Hplc final
Page 14: Hplc final

Reactants and conditions must be chosen so that conversion to the desired product(s) takes place rapidly (usually < 1 minute) and reproducibly.

PCD system must ensure good mixing

If the conversion is not sufficiently rapid, it may be necessary raise the temperature, incorporate a catalyst or in some other way accelerate the rate of derivatization.

completeness of reaction is not always a required result.

In many qualitative applications it may be sufficient that each analyte derivative be formed in abundance great enough to generate a detectable signal.

IMPORTANT CONSIDERATIONS IN POST COLUMN DERIVATIZATION

Page 15: Hplc final

REAGENTS FOR DERIVATIZATION Derivatization for UV-Detectors :

Ninhydrin a chromatag is commonly employed to yield corresponding derivatives of amino acids that show absorption specifically at about 570 nm as shown in the following reaction :

Page 16: Hplc final
Page 17: Hplc final

Derivatization for Fluorescence Detectors

Dansyl Chloride (a fluorotag) is invariably used to obtain fluorescent derivatives of proteins, amines and phenolic compounds, the excitation and emission wavelengths being 335 to 365 nm and 520 nm respectively.

Page 18: Hplc final

Reagents for flouroscent derivatization

Page 19: Hplc final

APPLICATIONDrug manufacturing control requires high level and intensive analytical and chemical support of all stages to ensure the drug's quality and safety

The pharmacopeia constitutes a collection of recommended procedures for analysis and specifications for the determination of pharmaceutical substances, excipients, and dosage forms.

Page 20: Hplc final

Used in Qualitative and Quantitative analysis.

Used in the routine assay of new drugs as well as substitutes for the older more

troublesome assays for marketed drugs.

Used in the studies of drug samples in biological fluids.

Isolation of natural pharmaceutical active compounds.

Control of microbiological process.

Used to study the impurity profile of the new drugs.