3
WebStat™ is a web-based communicating thermostat system built around the T7350H- WebStat™ fills the growing need for simple, low cost web-based
HVAC automation systems
- WebStat™ saves money!
WebStat™ Introduction
WebStat™
T7350H
T7350H
T7350H
T7350H
Energy Savings
Trending & Alarming
Remote Monitoring & Programming
Floor Plan Graphics
Wiring Diagram
Generation
5
Barriers to BAS Implementation
4 out of Top 5 Involve Cost Issues!
• WebStat™ bridges the gap between standalone controls and expensive automation systems
• WebStat meets your cost targets
6
Your Y-pack W7350A1000
1. Y-pack contents:- J7350A1000 WebStat controller
- NPB-LON Lon Card
- NPB-WPM-US Power supply
- Quick Start-Up Guide (63-2657); to be used as the network installation guide
- User Guide (63-2658)
- WebStat Mounting and Wiring Instructions Guide????
2. For Installation, the following is needed:- Router/Hub with power supply
- A pair of ethernet CAT5 cables with RJ-45 end connectors
- Laptop PC for initial controller configuration requirements
- A plan to layout your network and a plan on how to add WebStat to your IT network
7
• End users and HBS can have access from anywhere- On site service calls can be avoided
Login quickly to view system parameters
- End users can change schedules and setpoints easily Privileges can be assigned to different users
Remote Monitoring and Programming
8
• One easy to use tool- Programmers and end users have the same interface
Privileges can be assigned to users, giving everyone only what they need and preventing unauthorized changes
- No software or licensing to buy Everything needed is integrated into the WebStat™
Single Universal Tool
9
• Allows trending of system parameters- Diagnostics can be performed without a site visit
End user saves time and money
Trending and Alarming
10
• Custom floor plans- Floor plan graphics make it easy to view thermostat
locations and more advanced information
- Up to 5 separate floor plans can be added
Floor Plan Graphics
11
• 365-Day Programming- Lets the thermostat be configured for holidays throughout the
year. “Set it and forget it!”
• Override Limits- Limits can be placed on override temperature selection and
override length
- Prevents end-users from driving up energy costs
• Economizer Output- Enables economizer operation when outdoor
air is adequate for conditioning the space Prevents expensive mechanical cooling when not required
- Can also be configured for time of day (TOD) Enables end user to turn off lighting or other energy-using
devices
Energy Savings
Economizer W7212
12
• Custom wiring diagrams- WebStat™ automatically creates a customized wiring
diagram for every thermostat in the system Faster installation Reduces wiring mistakes in the field
Wiring Diagram Generation
14
Performance Requirements/Applications
• Thermostat Device Nodes (12)• Alarms (200), Schedules (5), Floor Plans (5), Trends (5)
- Two points per trend
• Device Discovery – self discovers thermostats• Multi-Tenant – built in multi-tenant features• Subnet NODE-ID
- Limited to 1 WebStat™ per network
• User Sign-On- Up to 3 users can be signed on simultaneously
15
Laying Out Your Network
• Network Security Provisions- For access to WebStat over the internet, a network firewall is
strongly advised
- A router can be used between the Cable/DSL modem and the WebStat controller to provide a hardware firewall. Software firewalls are also widely available to load onto the router.
• IT Administrator- Obtain permission from the IT Administrator to add the WebStat
to the network. If there is a strong objection from the IT Administrator, keep in mind that the WebStat can be placed on its own unique network. (A separate Cable/DSL modem and router would be required)
• Access to Router Ports- WebStat uses the following ports and they must be open:
Port 80 –HTTP access Port 3011 – Niagara platform daemon access port (for loading trend
feature) Port 1911 – Required to be open to view trend feature
16
Sales Strategies For Growing Webstat Business
• Up sell existing customer base from stand-alone- 30 Billion Sq. ft. of commercial floor space potential
• Up sell small dial up systems, LonSpec up sell• Target mechanical and service contractors who are
just starting in automation• Capitalize on the growing dependent trend on web
accessibility• Provide a simple solution where a complete
automation system doesn’t meet the current customer needs- Remote buildings that can’t be pulled in (cost, complexity, etc.)- New opportunity that can be leveraged into a service
opportunity- Customer with potential upgrade capabilities
• Memorize the 4 key benefits to end users and CE’s- Low Cost, Simplicity, Energy Savings, Reliable Performance
17
How To Order
• WebStat™ is available to Authorized Systems Distributors and Commercial Controls Distributors
Product OS Number Description Make Market Base Price
WebStat™ Controller Y-Pack
W7350A1000Contains one WebStat™ controller, one
Lon Card (NPB-LON) and one power supply (NPB-WPM-US)
$1995 per unit
Staged Thermostat T7350H10093H/3C or 2H/4C Conventional and 3H/2C
Heat Pump $679.58 per unit
Modulating Thermostat
T7350H1017Two 4-20mA outputs plus 3 additional
staged outputs $731.85 per unit
DIN Rail Power Supply (optional)
NPB-PWR24V DIN Rail Power Supply
$213.20 per unit
18
Sensor Accessories – T7350
• Remote Sensing, Economizer integration are top customer needs
- Indoor – 20K average
- Outdoor – 3K PT
- Humidity
- Discharge Air – 20K
T7771A1005 T7770C1044 2%, 3%, 5% accuracy models
C7041B
C7031G2014
19
Literature & Training Information• New Products Site
- http:/customer.honeywell.com/buildingsSelect Automation System, then WebStat Controller
Sales Training, Installation Training, Marketing Materials
• Literature – http:/customer.honeywell.com
20
Webstat™ Demo
http://69.29.17.24 or http://www.webstathoneywell.comUser ID = honeywellPassword = honeywell