IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA1
IntelligentTimeCodeDistributionAmplifierIBU-160i
OperationandMaintenanceManual
P/N:900000152REVA
ForBrandywineCommunicationsproducts
withthefollowingPartNumbers:01900100X
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA2
Safety Warnings
WARNING: This unit contains lethal AC voltages. Disconnect the unit from the AC supply before removing the cover.
WARNING:This unit contains dual power supplies. Isolate BOTH power supplied from AC Power before removing the top cover.
WARNING:The lightning flash with an arrowhead inside of an equilateral triangle is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure. The “dangerous voltage” may be of sufficient magnitude to constitute a risk of electrical shock to people. Do not attempt to repair the unit without first unplugging it.
CAUTION:The exclamation point inside of an equilateral triangle is intended to alert the user to the presence of important operation and maintenance instructions in the user guide. Only qualified personnel should repair this unit. Several board assemblies contain static sensitive devices. Appropriate procedures must be used when handling these board assemblies.
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA3
RevisionHistory:Revision DateA 04/22/2016
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA4
TableofContents
1 INTRODUCTION 5
2 UNPACKINGTHEIBU-160I 52.1 INSTALLATION 52.1.1 MOUNTING 52.1.2 POWER 62.1.3 ETHERNET 62.1.4 TIMECODEINPUTS 62.1.5 TIMECODEOUTPUTS 62.1.6 CONSOLEPORT 62.1.7 ALARMOUTPUTPORT 6
3 SETTINGUPTHEIBU-160I 7
4 ACCESSINGTHEIBU-160I’SNETWORKINTERFACE 84.1 ACCESSINGFUNCTIONSONTHEIBU-160I 84.1.1 VIEWINGTHECURRENTSTATUSOFTHEIBU-160ISYSTEM 9
5 CHANGINGTHESETTINGSONTHEIBU-160I 105.1 SELECTINGAREFERENCE 105.1.1 CHANGINGTHEREFERENCESWITCHMODE. 115.2 ADJUSTINGTHEOUTPUTSETTINGS 125.3 CHANGINGTHEIPADDRESS 135.4 CHANGINGSNMPSETTINGS 145.4.1 MONITORINGTHEIBU-160IUSINGSNMP 145.5 CHANGINGTHELOCATIONSETTING 155.6 CHANGINGTHEACCESSPASSWORD 16
6 ALTERNATEACCESS 176.1.1 USERCOMMANDSANDRESPONSES 17
7 SUPPORTINFORMATION 20
8 FRONTPANELVIEW 21
9 REARPANELVIEW 22
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA5
1 IntroductionTheIRIGDistributorUnit(IBU-160i)provides16isolatedmodulatedtimecode
outputsbasedonaselectedinputreference.Thecodeoutputisalwaysthesameastheinput.TheIBU-160iprovidesreferenceselection,isolationandindividualamplitudeadjustment.
TheIBU-160iiscontainedinacompactIUrack-mountchassis.TheIBUacceptstwosetsofinputs,comprisingthereferenceIRIGinputandstatusfromthesource.TheIBUprovidesautomaticchangeovershouldoneoftheon-linesourceinputsfail.Manualsourceselectoverrideisavailableonthefrontpanel,orthroughtheEthernetinterface.
Avarietyofstatusindicatorsarelocatedonthefrontpanelforinstantvisualfeedback,togetherwithmanualcontrolsforsourceselection.
A10/100baseTEthernetinterfaceprovidesfullcontroloverthefunctionalityofthesystem,includingreferenceselectionandoutputamplitude(onaperchannelbasis).
Usercontroloftheunitisviaabuilt-inWebBrowserwithuser-friendlygraphicalinterface,orviaSNMPforsystemapplications.
ApplicationsfortheIBU-160iincludetestranges,satellitecontrolcenters,shipboardtimedistribution,airports,railterminals,andanysystemrequiringhighlyreliabletimecodedistribution.
2 UnpackingtheIBU-160iRemovetheIBU-160fromtheshippingcarton.Thefollowingitemsshouldbeincludedintheshipment:1xIBU-160i2xPowersupplycables1xQuickStartGuide
2.1 Installation
2.1.1 MountingTheIBU-160icanbeinstalledintoa19”rackmountcabineteitherusingrackslidesoronlyusingthefrontpanelflanges.Forstaticapplications,theshortdepthandlightweightoftheIBU-160iensuresthatthefrontpanelisnotstressedwhenonlythefrontpanelisusedforsupport.IftheIBU-160iisinstalledonamobileplatformandmustsurviveshockandvibration,theuseofslidesisrequired.Slidesareinstalledusing10-32UNF-2Bhardware.OptionalRackMountSlides:P/N002000123,SLIDE,RACK,24",21"TRAVEL,85LB
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA6
P/N002000150,SLIDE,RACK,28",27"TRAVEL,80LBOriginalManufacturer:GeneralDevicesChassisTrakTypeC300.
2.1.2 PowerInsertthepowercordoftheIBU-160iintoanelectricalsockettopoweruptheunit.ThePowerLEDindicatorwillilluminategreen.Ifdualredundantpowerisrequired,connectbothpowersourcestoindependentpowersources
2.1.3 EthernetConnectoneendofanEthernetpatchcabletotheIBU-160iEthernetportJ21.ConnecttheotherendoftheEthernetcabletothenetworkwithanEthernethuborswitch.
2.1.4 TimeCodeInputsConnectatimecodeinputsourcestothetimecodeinputconnectorsJ17and/orJ18.ChannelAInputisJ18,andChannelBisJ17.
2.1.5 TimeCodeOutputsConnectthetimecodeoutputsJ1throughJ16tothecoaxialinfrastructure.
2.1.6 ConsolePortConnectaDB-9FcabletoportJ20inordertoenableRS-232accesstotheunit.(Straight,pin3isRXpin2isTX)
2.1.7 AlarmOutputPortConnectaDB-9McabletoportJ19toaccessthealarmoutputport.Pleaseseethefollowingdiagramforthepinoutoftheconnector:
Figure1-Alarmoutputpinout
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA7
3 SettinguptheIBU-160iPoweronthesystembyflippingswitchesSW1andSW2ontherearoftheunittotheonposition.Thesystemwilldisplayitspower-oncycleonthefrontpanel.ThesystemwilluseLEDlampsD7throughD17toindicateeachoctetofthedevice’sIPAddress,NetworkMask,andGatewayaddress.Writethesevaluesdownandkeeptheminasafeplace.TodisplaytheIPaddressagain,thefrontpanelcanberesetbypressingtheRESETswitch(SW2)onthefrontpanel.
Figure2-IBU-160iShowingIPAddress
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA8
4 AccessingtheIBU-160i’sNetworkInterfaceConnecttotheIBU-160ibyenteringtheunit’sIPaddressintotheaddressbarofthewebbrowseronaPC,SmartphoneorTablet.
Figure3-IBU-160iWebPageInterface
UsethedropdownmenutoselectdifferentfunctionsoftheIBU-160itoviewthestatusofthesystemandtoadjustdifferentfunctionsoftheunit.
4.1 AccessingFunctionsontheIBU-160i
ToaccessdifferentfunctionsoftheIBU-160imanagementwebpage,selectthebuttonlabeled“MENU”inthetoplefthandcornerofthewebpage.
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA9
4.1.1 ViewingtheCurrentStatusoftheIBU-160isystemFromthe“MENU”button,select“General”fromthestatusmenu.Thisshowsinformationsuchasthecurrentoutputtime,UTCtime,uptime,thecurrentinputreference,thecurrentoutputformat,currentsystemstate,andalarmstatus.
Figure4-IBU-160iStatusPage
OutputTime:ThecurrenttimeofdaybeingdisplayedorbeingoutputbytheIBU-160iUTCTime:ThecurrenttimeofdayfromtheGPSconstellationinUniversalTimeCoordinate(UTC)UpTime:ThelengthoftimethattheIBU-160ihasbeenpoweredonHourMeter:ThisistheaccumulatednumberofoperatinghourssincetheIBU-160iwasfirstbuilt.Reference:ThecurrentreferenceinputbeingusedbytheIBU-160iSystemAlarms:IfthesystemiscurrentlydisplayinganyalarmsOutputUnits:Thecurrentunitthesystemisusing
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA10
5 ChangingtheSettingsontheIBU-160i
Figure5-ReferenceSettingsPage
5.1 SelectingaReference
Fromthemenu,select“Reference”fromthesettingssubmenu.Fromthe“SelectReference”dropdownmenu,selectbetweenreferencesourcesA(J18)orB(J17).
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA11
5.1.1 Changingthereferenceswitchmode.Fromthedropdownlabeled,“SelectReferenceSwitchMode,”selectwhichmodetheunitusestoswitchreferencesintheeventofaproblem.Theavailablemodesarelistedbelow.
• Non-Reversionary: Iftheprimaryreferencesourcefailsorisoutofthreshold,thesystemwillautomaticallyswitchovertothesecondaryreferencesource,andcontinuetousethesecondaryuntilmanuallyswitchedbacktotheprimarysource,orthesecondarysourcefailsandthesystemautomaticallyswitchesbacktotheprimary.
• Reversionary: Thesystemwillswitchtothesecondarysourceautomaticallyiftheprimarysourcefailsorisoutofthreshold,howeveroncetheprimarysourceisrestored,theunitwillimmediatelyswitchback
• ReversionarywithDelay: Thesystemwillautomaticallyswitchtothesecondarysourceintheeventtheprimarysourcefailsorisoutofthreshold.Oncetheprimarysourceisrestored,itwillautomaticallyswitchbackafterwaitingforauser-specifieddelay.Thissettingisusefulforhelpingtheunitdealwithintermittentproblemsonaprimarytimecodesource.
5.1.1.1 Adjustingthereversionarydelay.Thetextbox“ReversionaryDelay”isusedtosetthedelaytimeinsecondsusedwhenthesystemissettothe“ReversionarywithDelay”ReferenceSwitchmode.
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA12
5.2 AdjustingtheOutputSettings
Figure6-OutputSettings
Fromthemainmenu,select“Output”fromthesettingssubmenu.ThisletstheuserchangetheOutputlevelsofeachindividualtimecodeoutput.
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA13
5.3 ChangingtheIPAddress
Fromthemainmenu,select“IP”fromthesettingssubmenu.Fromhere,theIPAddress,SubnetMask,andGatewayaddressoftheunitcanbeselected.Inaddition,itispossibletoenableDHCP,howeverthisactionisnotrecommended.
Figure7IPAddressSettings
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA14
5.4 ChangingSNMPSettings
Fromthemainmenu,select“SNMP”fromthesettingssubmenu.FromheretheReadCommunity,WriteCommunity,andTrapIPAddresscanbeset.
Figure8-SNMPSettings
5.4.1 MonitoringtheIBU-160iusingSNMPTomonitortheIBU-160iviaSimpleNetworkManagementProtocol(SNMP),downloadaMIBfilefromtheSupportDownloadssectionoftheBrandywineCommunicationswebsite.(http://www.brandywinecomm.com/product-support/downloads)
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA15
5.5 ChangingTheLocationSetting
Fromthemainmenu,select“Location”fromthesettingssubmenu.Thissettingtellstheuserwheretheunitisphysicallylocatedwithinafacility.(e.g.Room102)
Figure9-LocationSettingScreen
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA16
5.6 ChangingTheAccessPasswordFromthemainmenu,select“Password”fromthesettingssubmenu.Fromheretheaccesspasswordfortheunittopreventotherusersfromchangingsettingscanbeset.ThecurrentUsernameandPasswordarerequiredinordertoresettheexistingusernameandpassword.Thefactorydefaultlogincredentialsare:Username:BRANDYWINEPassword:BRANDYWINE
Figure10-PasswordSettings
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA17
6 AlternateAccessIftheunitisinanareawhereitcannotbeaccessedoverthenetwork,butphysicalaccesstothedeviceisstillpossible,theIBU-160icanstillbeaccessedandcontrolledviaRS-232overtheserialport.
6.1.1 UserCommandsandResponses TheIBU-160iSerialport(115200,8,1,1,noparity)providesstatusandsettingdataonrequestfromtheuser.TheusercanobtaininformationfromtheIBU160ibysendingHELPcommandterminatedbyCR.TheIBU160iwilldisplaytheHELPMENUasbelow:
-----------------------------------------------------------------------------------------------IBU160iSystemSetup-(925000120)1.01.05Jul92013SN#36770-HardwareVer:A-----------------------------------------------------------------------------------------------COMMANDDescription----------------------------------------------------------------------------------------------HELP ShowthisscreenIPADDR IPAddress(setto0.0.0.0toenableDHCP)(192.168.1.121)IPMASK IPMask(255.255.255.0)IPGATEWAY IPGateway(192.168.1.1)MACADDR MACAddress(00-21-34-00-02-EB)FACT FactoryResettoDefaultsSettingRESET ResetSystemEnteramenucommand:
TheIBU-160iusercommandsaredescribedinthetablebelow.
COMMAND FUNCTION COMMENTS HELP ShowHelp ShowHelpMenu
Example:HELP<CR>DisplaystheaboveHelpMenu.
IPADDR SetIPAddress SettheIPAddress(decimalnumber)IP4,IP3,IP2,IP1andStoreintoNVM.
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA18
Example:IPADRR<CR>New Setting:192.168.1.121<CR> SetstheIPaddressto192.168.1.121anddisplaystheaboveHelpMenu.ToenableDHCPenterIPaddress0.0.0.0<CR>
IPMASK SetIPMaskAddress
Set/GettheIPMaskAddress(decimalnumber)IP4,IP3,IP2,IP1andStoreintoNVM.Example:IPMASK<CR>New Setting:255.255.255.0<CR> SetsIPMaskanddisplaystheaboveHelpMenu.
IPGATEWAY SetGatewayAddress
Set/GettheGatewayAddress(decimalnumber)Gateway4,Gateway3,Gateway2,Gateway1andStoreintoNVM.ExampleIPGATEWAY<CR>NewSetting:192.168.1.1SetsIPGatewayanddisplaystheaboveHelpMenu.
MACADDR SetMACAddress Set/GettheMaskAddress(decimalnumber)Mask4,Mask3,Mask2,Mask1andStoreintoNVM.Example:MACADDR<CR>New Setting: 00-21-34-00-02-EB<CR>SetsMACaddressanddisplaystheaboveHelpMenu.
FACT RecallFactorydefaults
RecallallfactorydefaultsettingsExample:FACT<CR>
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA19
Areyousureyouwanttocontinue(Y/N)?YResetstofactorydefaultanddisplaystheaboveHelpMenu.
RESET ResettheUnit ResettheUnitExample:RESET<CR>Areyousureyouwanttocontinue(Y/N)?YResetSystemResetstheunitanddisplaystheaboveHelpMenu.
Upgrade Application
UsePIC32BootloaderApplicationprogramtoupgrademainapplicationthroughEthernet.Followthebelowcommands:1. RunthePIC32UBL.exe2. ChecktheEthernetEnablecheckedbox.Make
suretheIPAddress=192.168.254.100.3. Hitthe“LoadHexFile”.Browseto“IBU-
160i.hex”tosendthehexfile.4. Hitthe“Upload”button. 5. Waitfortheprogressionbarstartingbefore
recyclethepowersupplysothattheprogramjumptobootloadersection.Thestatusshoulddisplaythebootloaderfirmwareversionsuchas"V1.1". Table 2
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual
P/N900000152REVA20
7 TroubleshootingProblem Solution
TheIBU-160iDoesnotpoweron Pleaseensurethatthesystemiscorrectlypluggedintopower,andthatbothpowersuppliesareconnected.
TheIBU-160ipowerson,thelightsflashbriefly,andthennothing.
Thesystemfirmwareisnotproperlyloaded.PleasecontactBrandywineCommunicationsforsupport
TheIBU-160ipowersupcorrectly,butthelightsflasherraticallyonceit’spoweredon.
Thesystemdoesnothaveavalidinputreferencefromeitherinputconnection.Pleasedouble-checktheinputconnectors.
8 SupportInformationAllBrandywineCommunicationsproductscomewithaone-yearwarranty.Iftheunitisstillexhibitingproblemsnotcoveredbytheabovetroubleshootingguide,pleasecontactusfortechnicalsupportatsupport@brandywinecomm.comorcallusat714-755-1050.Ifitbecomesnecessarytoreturntheunittothefactoryforrepairs,pleasecallusat714-755-1050extension113toarrangeanRMA.
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManualP/N900000152REVA
21
9 FrontPanelView
IBU-160i
IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManualP/N900000152REVA
22
10 RearPanelView