Deploying FlexPodinfrastructures, best

practices from the fieldRamses Smeyers – Technical Leader Services

BRKVIR-2260

Page 3: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• A collection of hints and tips gathered while deploying, managing and troubleshooting FlexPOD deployments for over 5 years

• Customer deployments

• TAC troubleshooting cases

• Customer / Partner sessions

What is this session about ?

Page 4: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• What is a FlexPOD ?

• Deployment gotchas

• Performance analysis

• Upgrade the stack

• UCS-Director automation

Agenda

Page 5: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

What is a FlexPOD ?

Page 6: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

What is a FlexPOD ?

• FlexPod is a integrated computing, networking, and storage solution developed by Cisco and NetApp. Its configurations and workloads are published as Cisco Validated Designs. FlexPod is categorized by established and emerging client needs

• Validated technologies from industry leaders in computing, storage, networking, and server virtualization

• A single platform built from unified computing, fabric, and storage technologies, with popular and trusted software virtualization

• Integrated components that help enable you to centrally manage all your infrastructure pools

• An open design management framework that integrates with your existing third-party infrastructure management solutions

Page 7: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

CVD

Page 8: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Architecture - Nexus

Page 9: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Architecture - ACI

Page 10: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Deployment gotchas

Page 11: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Deployment gotchas

• MTU 9000

• ALUA

• FCoE

• Management / production network overlap

• Hypervisor load-balancing

• ACI Dynamic discovery

Page 12: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

MTU 9000

Page 13: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• Problem ? End-2-End MTU 9000 is not working

• MTU needs to be defined @

• VMware

• Nexus 1000V (if NFS traffic is handled by Nexus 1000V)

• UCS

• Nexus 5000

• NetApp

• Use the correct ping on VMware

• ~ # vmkping -I vmk1 -s 9900 42.33.80.6

• PING 42.33.80.6 (42.33.80.6): 9900 data bytes

• 9908 bytes from 42.33.80.6: icmp_seq=0 ttl=255 time=0.355 ms

• ~ # vmkping -I vmk1 -s 9900 42.33.80.6 -d

• PING 42.33.80.6 (42.33.80.6): 9900 data bytes

• sendto() failed (Message too long)

MTU 9000

With –d >8972 will

not work (-d do

not fragment)

Page 14: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

VMware

Page 15: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Nexus 1000V

• Global• bdsol-vc01vsm-01# show running-config | inc jumbo

• bdsol-vc01vsm-01# show running-config al | inc jumbo

• system jumbomtu 9000

• Port-profile

• bdsol-vc01vsm-01(config)# port-profile type ethernet Uplink

• bdsol-vc01vsm-01(config-port-prof)# system mtu 9000

• Check• bdsol-vc01vsm-01# show interface ethernet 3/3

• Ethernet3/3 is up

• Hardware: Ethernet, address: 0050.5652.0a1f (bia 0050.5652.0a1f)

• Port-Profile is Uplink

• MTU 1500 bytes

• Encapsulation ARPA

Page 16: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• Define MTU on

• QOS System Class

• vNIC template

• QoS Policies

UCS

Page 17: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf
Page 18: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf
Page 19: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf
Page 20: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Nexus 5000 Nexus 7000

policy-map type network-qos jumbo

class type network-qos class-fcoe

pause no-drop

mtu 2158

class type network-qos class-default

mtu 9216

multicast-optimize

system qos

service-policy type network-qos jumbo

system jumbomtu 9216

interface Ethernet1/23

mtu 9216

Page 21: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

NetApp

bdsol-3240-01-B> rdfile /etc/rc

hostname bdsol-3240-01-B

ifgrp create lacp dvif -b ip e1a e1b

vlan create dvif 3380

ifconfig e0M `hostname`-e0M flowcontrol full netmask 255.255.255.128 mtusize 1500

ifconfig e0M inet6 `hostname`-e0M prefixlen 64

ifconfig dvif-3380 `hostname`-dvif-3380 netmask 255.255.255.0 partner dvif-3380 mtusize 9000 trusted wins up

route add default 10.48.43.100 1

routed on

options dns.enable on

options nis.enable off

savecore

bdsol-3240-01-B> ifconfig dvif-3380

dvif-3380: flags=0x2b4e863<UP,BROADCAST,RUNNING,MULTICAST,TCPCKSUM> mtu 9000 dad_attempts 2

inet 42.33.80.2 netmask 0xffffff00 broadcast 42.33.80.255

inet6 fe80::a0:98ff:fe36:1838 prefixlen 64 scopeid 0xd autoconf

partner dvif-3380 (not in use)

ether 02:a0:98:36:18:38 (Enabled interface groups)

Page 22: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• Traffic flow (NFS is on Gold)

• VMware UCS (Gold CoS 4) 5K NetApp

• NetApp 5K UCS (Best Effort) vNIC Drop (no CoS on traffic)

• Solution

• Remark traffic on Nexus 5000 NetApp interfaces to CoS 4

• ACL to match NFS traffic remark to CoS 4

Watch out for return traffic

Page 23: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

ALUA

Page 24: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

ALUA ?

Page 25: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Verify ALUA on VMware

Page 26: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

~ # esxcli storage nmp device list

naa.60a98000443175414c2b4376422d594b

Device Display Name: NETAPP Fibre Channel Disk

(naa.60a98000443175414c2b4376422d594b)

Storage Array Type: VMW_SATP_ALUA

Storage Array Type Device Config: {implicit_support=on;explicit_support=off;

explicit_allow=on;alua_followover=on;{TPG_id=2,TPG_state=AO}{TPG_id=3,TP

G_state=ANO}}

Path Selection Policy: VMW_PSP_RR

Path Selection Policy Device Config:

{policy=rr,iops=1000,bytes=10485760,useANO=0;lastPathIndex=3:

NumIOsPending=0,numBytesPending=0}

Path Selection Policy Device Custom Config:

Working Paths: vmhba2:C0:T0:L0, vmhba1:C0:T0:L0

Is Local SAS Device: false

Is Boot USB Device: false

Page 27: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Verify ALUA on NetApp

bdsol-3220-01-A> igroup show -v

bdsol-esxi-23 (FCP):

OS Type: vmware

Member: 20:00:00:25:b5:52:0a:0e (logged in on: 0d, vtic)

Member: 20:00:00:25:b5:52:0b:0e (logged in on: 0c, vtic)

UUID: 6c2a1c9a-f539-11e2-8cbf-123478563412

ALUA: Yes

Report SCSI Name in Inquiry Descriptor: Yes

igroup show -v <group>

igroup set <group> alua yes

igroup show -v <group>

Page 28: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

FCoE

Page 29: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Nexus 5000interface vfc103

bind interface port-channel103

switchport trunk allowed vsan 70

no shutdown

interface port-channel103

description bdsol-6248-03-A

switchport mode trunk

switchport trunk allowed vlan 970

interface Ethernet1/3

description bdsol-6248-03-A

switchport mode trunk

switchport trunk allowed vlan 970

spanning-tree port type edge trunk

spanning-tree bpdufilter enable

channel-group 103 mode active

Page 30: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• Default policy (show running-config all)policy-map type network-qos fcoe-default-nq-policy

class type network-qos class-fcoe

pause no-drop

mtu 2158

class type network-qos class-default

multicast-optimize

system qos

service-policy type fcoe-default-nq-policy

• cisco.com documented MTU 9000 Policypolicy-map type network-qos jumbo

class type network-qos class-default

mtu 9216

multicast-optimize

system qosservice-policy type network-qos jumbo

QOS policy

No FCoE

defined

Page 31: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

UCS

Page 32: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Management / production network

overlap

Page 33: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• Problem customer is unable to reach the UCS management interface (+ NetApp and Nexus 5000)

• Situation:

• Topology: Netapp Nexus 5000 UCS

• Mgmt topology 3750 connected to NetApp mgmt / Nexus 5000 mgmt0 / UCS management + connected to Nexus 5000 via port-channel / VPC

• Management VLAN is also used for Server / VM traffic

• Cause:

• VM/Server caused ethernet/VLAN overload on 3750 due to broadcast flooding

Management / production network overlap

Page 34: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Hypervisor load-balancing

Page 35: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Hypervisor load-balancing – UCS-B

Each Fabric Interconnect has a port-channel towards the Nexus 5000 vPC pair

Fabric interconnects are connected for clustering no data traffic is on the link

The hypervisor running on a blade has 2 independent connections no switch dependent protocols can be used

Using IP-hash algorithms will cause MAC flaps on the UCS FI’s and N5K’s

Page 36: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf
Page 37: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

ACI - Port-group traffic distribution settingsBy default, port-groups instantiated on the DVS default to ‘route based on originating virtual

port-id’ which is. This works well with all types of servers.

If you attach a LACP policy to your vSwitch Policies, you will set the traffic distribution to IP

hash! Be careful with UCS-B series as this is not supported (no vPC between the FIs).

See also “Setting up an Access Policy with Override Policy for a Blade Server Using

the GUI” http://www.cisco.com/c/en/us/td/docs/switches/datacenter/aci/apic/sw/1-x/getting-

started/b_APIC_Getting_Started_Guide/b_APIC_Getting_Started_Guide_chapter_010.html

#d19263e464a1635

Page 38: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

ACI Dynamic discovery

Page 39: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Prerequisites & Supported Config

• For Dynamic EPG download, we support only one L2 Hop between Host/ESX and iLeaf

• Management Address *Must* to be configured on L2/BladeSwitch.

• CDP or LLDP must be configured to advertised Mgmt-TLV on BladeSwitch

• UCS-FI need to be on version 2.2(1c) or later

• If there is need for multiple L2 hops, EPG with static Binding (using node+port selectors) should be used.

Page 40: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

ESX Discovery in FabricFor Dynamic download of policies to Leaf

APICvCenter

1

2

3 1. Leaf send LLDP* to ESX(includes Leaf port name)

2. ESX send parsed LLDP information to vCenter

3. APIC receives LLDP information from vCenter

4. APIC download Policy for VMs behind ESX to the Leaf node when using immediate

4

*Can use CDP instead of LLDP

Page 41: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• LLDP enabled VIC consumes LLDP

C-Series disable LLDP

Page 42: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

ESX Discovery in Fabric (with Blade Switch)

For Dynamic download of policies to Leaf

APICvCenter

1

31. Blade Switch sends LLDP* to

Leaf and ESX

2. ESX & Leaf send parsed LLDP information to vCenter & APIC resp.

3. APIC receives LLDP information from vCenter

4. APIC download policy on all Leafs providing path to the ESX when using immediate

2

1

2

4

*Can use CDP or mix of CDP/LLDP

Page 43: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

ESX Discovery issue with UCSOn FI LLDP works for fabric links, but not for host-facing links

IOM

APIC

IOM

PALO

LLDP not working, Enable CDP through

policy config

Fabric Uplinks Host Links

Option-1 LLDP CDP

Option-2 CDP CDP

Scope of CDP policy is UCS-FI to

ESX server. Supported through

Attach Entity Profile override

LLDP/CDP

Page 44: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

CDP for ESX discovery

Approach Details

No change • Static EPG at Leaf ports

• Opflex using N1K

Configuration change • Enable CDP policy for VNICs in UCSM service profile

• APIC (2 options)

1. CDP override for Host <->UCSBI using Attach entity Profile

Override

• CDP on ESX/DVS

• LLDP on fabric/Leaf

2. Set CDP as default policy throughout

• CDP on ESX/DVS

• CDP on fabric/Leaf

FCS : Options for UCS B-series deployment

Page 45: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Verify CDP is enabled on DVS/Hosts

Page 46: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Performance analysis

Page 47: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

UCS - recap

Page 48: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

What affects Performance?

Congestion

Oversubscription

PFC

B2B Credits

HIF

NIF

VIF

LIF

UIF

Buffers

Pinning

Sliding windowRSS

Tx Queues

Rx Queues

LSO

Arbitration

TCP Offload

Driver

Hashing

MRU

Round Robin

Fixed PathMultipathing

Port Channel

Firmware

QoS

CoS

Flow Control

Queue Depth

Power

Heat

Page 49: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Divide & Conquer

UCS Performance Areas can be categorized into the following areas:

Infrastructure Fabric Interconnects

IOMs

Adapters

SPFs/Cables

Platform

BIOS

Chipset

Adapter Settings

OS Specific

Windows vs. Linux

TCP vs. UDP vs. Multicast

RSS

CPU Affinity

Interrupts

We’ll focus on these areas

Page 50: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Egre

ss

UC

S B

lade

Chassis

FE

X/I

nte

rco

nn

ect A

FE

X/I

nte

rco

nn

ect B

LAN

Bla

de S

erv

er

CN

AO

S

Eth0

MAC A

Eth1

MAC B

OS NIC Teaming

CNA Port 1 CNA Port 2

Which path will UCS choose?

?In

gre

ss

Page 51: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

UCS Frame Flow DecisionsEgress

Which port in the port channel?

(2-8 choices)

Which uplink/border port or port channel?

(many choices)

Local or remote destination?

(2 choices)

Which Fabric Port?

(4 choices)

Which CNA Port?

(2 choices)

Which PCIe Ethernet Interface?

(1-58 choices depending on CNA)

OS Routing Table or

OS NIC Teaming

UCS Fabric Failover

Fabric Port Pinning

L2 Switching in FIs

Border Port Pinning

Port Channeling Algorithm

UC

S B

lade

Chassis

FE

X/I

nte

rco

nn

ect A

FE

X/I

nte

rco

nn

ect B

LAN

Bla

de S

erv

er

CN

AO

S

Eth0

MAC A

Eth1

MAC B

OS NIC Teaming

CNA Port 1 CNA Port 2

Page 52: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

UC

S B

lade

Chassis

UCS Frame Flow DecisionsIngress

Which downlink or port channel?

Allow the frame inbound?(decision depends on ‘switch mode’ vs. ‘end host mode’)

Which Fabric Extender Port?

Which Server Bay Port?(8 choices)

Which PCIe Device (vNIC)?(1-58 choices depending on CNA)

Pass frame to OS?Dest. MAC and Ethertype

binding

VNTag Identifier

VNTag + Offset

(MAC Learning on FIs)

Déjà vu, RPF, border port

pinning

(Upstream Switch Decides)

FE

X/I

nte

rco

nn

ect A

FE

X/I

nte

rco

nn

ect B

LAN

Bla

de S

erv

er

CN

AO

S

Eth0

MAC A

Eth1

MAC B

OS NIC Teaming

CNA Port 1 CNA Port 2

Fabric Port Pinning

Page 53: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Infrastructure Path Tracing

Page 54: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

System Components – Hop by Hop

Trunk Interface

Fabric Interface

NIF (Network)

HIF (Host)

UIF (Uplink)

VIF (Virtual)

NXOSUCSM

Page 55: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

System Components – ASICs (Gen 1 vs. Gen 2)

• Fabric ASIC : Altos/Sunnyvale

• Port ASIC : Gatos/Carmel

• FEX ASIC : Redwood/Woodside

• VIC ASIC : Palo/Sereno

• Gen-1 CNA ASIC : Menlo

Fabric

Switch

Compute ChassisCompute Chassis

Compute Chassis

Fabric

Switch

Compute Blade

(Half slot)

x86 Computer

Compute Blade

(Full slot)

x86 Computer

Adapter

X

Fabric

ExtenderI

Fabric

ExtenderI

x8x8x8x8

C

MGMT

SS

Adapter AdapterC

X X X X X

CC

F

P P

P P

SAN

P

L

F

P

P P

P

L

P

VC V

SANLAN

Page 56: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Why do I care about ASIC names?

fex-1# show platform software woodside rate

fex-1# show platform software redwood sts

TSI-UCS-A(nxos)# show hardware internal carmel crc

TSI-UCS-A(nxos)# show hardware internal sunny event-history errors

Page 57: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Narrowing Down the Problem

• Define the problem

• From which point to what other point is the problem?

• Do we see the problem in one direction or both?

• Eliminate variables

• Is the problem seen between traffic traversing the same fabric?

• Is the problem only happening on a specific path?

• List all the ports in the traffic path

• VIFs, FEX, HIFs, NIFs, Fabric and Uplink ports

Page 58: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Defining the Ports

• FI Uplink/Trunk Port

• The Fabric Interconnect defines Uplink ports as those ports connecting to the LAN

• Always in trunk mode (no such thing as mode access configuration)

• VLAN 1 is default (native) & can be changed

• Port-channel configuration allowed (LACP only)

• There is currently no vPC or Fabric Path feature in the FI

Page 59: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Defining the Ports

• Fabric Interconnect FEX-Fabric aka Server Interfaces (SIF)

• The Fabric Interconnect (FI) defines fex-fabric ports as those ports connecting to the IOMs in the chassis

• IOM Host Interfaces (HIFs) ports are statically pinned to FEX-fabric ports (SIF)

• Same concept Nexus FEXs use with Satellite ports.

Note: The term “FEX” and “IOM” are commonly used interchangeably

Page 60: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Defining the Ports

• IOM Network Interfaces (NIF)

• The IOM defines these ports which are external connecting the IOM to the FI.

• NIF port are either configured as individual or channeled to the FI’s as server ports (SIF) – depends on model of IOM.

• Same concept Nexus FEXs use with Satellite ports.

Page 61: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Defining the Ports

• IOM Host Interfaces (HIFs)

• Each IOM provides a number of internal ports per blade

• IOM model 2104XP provides 8x internal ports (one for each blade)

• IOM model 2204XP provides 16x internal ports (two for each blade)

• IOM model 2208XP provides 32x internal ports (four for each blade)

• Each HIF is defined by three different values, EthX/Y/Z. Chassis/Adapter/Slot

Page 62: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Defining the Ports

• Adapter Uplink Interface (UIFs)

• Each Adapter has 2 physical uplinks, one to each uplink

• References as 0 and 1

• These are also known as the Data Center Ethernet (DCE) Interfaces

Page 63: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Defining the Ports

• Virtual Interface (VIF)

• Defined as Ethernet (veth) or Fibre Channel (vfc)

• A vNIC with Fabric Failover enabled will have two VIFs assigned (Primary & Backup)

• Represent the vNIC or vHBA on the compute blade towards OS

• Pinned automatically or manually (pin groups) to border port or FC uplink ports

• veth and vfc numbers are dynamically assigned

• System automatically allocates a certain number of VIFs per service-profile for its own management/control traffic

Page 64: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Defining the Ports

• Logical Interfaces (LIF)

• Represent the logical interface of a VIF pair (those with Fabric Failover enabled)

• LIF indexes are managed at the adapter level

• Not visible within UCSM

Logical Interface (LIF)

Page 65: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Trace Example• Let’s trace the path for the

first vNIC (eth0) on blade 1/6

• First, what’s the VIF # ? Blade 1/6

FEX 1

Fabric A

FEX 2

Fabric B

0 1

Eth0 (00:25:b5:44:00:3b )

Page 66: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

VIF Pinning – Service Profile View• UCSM top level : show service-profile circuit server <chassis#>/<slot#>

UCS-A# show service-profile circuit server 1/6

Service Profile: roberbur/Perf-Test-3

Server: 1/6

Fabric ID: A

VIF vNIC Link State Oper State Prot State Prot Role Admin Pin Oper Pin Transport

---------- --------------- ----------- ---------- ------------- ----------- ---------- ---------- ---------

9178 Up Active No Protection Unprotected 0/0 0/0 Ether

986 fc0 Up Active No Protection Unprotected 0/0 0/0 Fc

988 eth1 Up Active Passive Backup 0/0 1/7 Ether

990 eth3 Up Active Passive Backup 0/0 1/7 Ether

991 eth0 Up Active Active Primary 0/0 1/7 Ether

993 eth2 Up Active Active Primary 0/0 1/7 Ether

Fabric ID: B

<snip>

Page 67: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

VIF Pinning – GUI vs CLI

Page 68: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Trace Example• We know eth0 is

assigned VIF 991 and we know eth0 is set to Fabric-A

• Next, which internal FEX port is VIF 991 using?

Blade 1/6

IOM 12204

Fabric A

IOM 22204

Fabric B

0 1

eth0 VIF 991

0

Page 69: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

IOM Internal Port Information – 2100XP• connect iom <chassis #>

• show platform software redwood sts

Which HIFs are active

legend:= no-connect

X = Failed- = Disabled: = Dn| = Up[$] = SFP present[ ] = SFP not present[X] = SFP validation failed

Page 70: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

IOM Internal Port Information – 2200XP• show platform software woodside sts

FEX Ports

Page 71: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

IOM 12204

IOM 22204

Trace Example• VIF 991 is using

FEX Port 11

• Which NIF is being used?

Blade 1/6

Fabric A Fabric B

0 1

eth0 VIF 991

FEX Port 11

Page 72: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

FEX to Fabric Port Pinning (2204XP)

IOM Fabric

Interconnect

NIF SIF

1-2

3-4

5-6

7-8

9-10

11-12

13-14

15-16

1

2

3

4Blade 6

Page 73: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

IOM 12204

Trace Example• VIF 991 is using

FEX Port 11, NIF 2

• Which SIF is used? Blade 1/6

Fabric A Fabric B

0 1

eth0 VIF 991

IOM 22204

NIF 2

FEX Port 11

Page 74: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

IOM Port Information• Connect nxos : show fex <chassis#> detail

Shows which Fabric Port

each FEX port is using

Page 75: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Trace Example• VIF 991 is using

HIF eth1/1/11, NIF 2, and bound to SIF e1/12

• Lastly, which uplink will be used?

Blade 1/6

Fabric A Fabric B

0 1

eth0 VIF 991

IOM 12204

NIF 2

Fabric Port Eth1/12

IOM 22204

HIF 11

Page 76: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

VIF Pinning – Fabric Interconnect View• Connect nxos : show pinning border-interface active

• Connect nxos : show pinning server-interfaces

UCS-A(nxos)# show pinning border-interfaces active

--------------------+---------+----------------------------------------

Border Interface Status SIFs

--------------------+---------+----------------------------------------

Eth1/7 Active Veth988 Veth990 Veth991 Veth993

Eth1/8 Active Veth963 Veth974 Eth1/1/3 Eth2/1/7

Total Interfaces : 2

UCS-A(nxos)# show pinning server-interfaces | i Veth

Veth956 No - -

Veth963 No Eth1/8 2:27:23

Veth974 No Eth1/8 2:27:23

Veth988 No Eth1/7 2:27:23

Veth990 No Eth1/7 2:27:23

Veth991 No Eth1/7 2:27:23

Veth993 No Eth1/7 2:27:23

Page 77: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Trace Example• VIF 991 is using

HIF eth1/1/11, NIF 2, and bound to SIF e1/12 and egress UCS on Uplink eth1/7

Blade 1/6

Fabric A Fabric B

0 1

eth0 VIF 991

IOM 12204

NIF 2

Fabric Port Eth1/12

IOM 22204

HIF 11

Vif 991

Uplink Eth1/7

Vif 991

Page 78: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

End-2-End storage performance

Page 79: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• Follow traffic from Hypervisor UCS N5K/MDS NetApp

• ESXtop

End-2-End storage performance

Page 80: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• Verify link oversubscription on IOM

IOM traffic

bdsol-6248-01-B# connect iom 2

fex-1# show platform software woodside rate

+--------++------------+-----------+------------++------------+-----------+------------+-------+-------+---+

| Port || Tx Packets | Tx Rate | Tx Bit || Rx Packets | Rx Rate | Rx Bit |Avg Pkt|Avg Pkt| |

| || | (pkts/s) | Rate || | (pkts/s) | Rate | (Tx) | (Rx) |Err|

+--------++------------+-----------+------------++------------+-----------+------------+-------+-------+---+

| 0-BI || 20 | 4 | 4.37Kbps || 10 | 2 | 2.23Kbps | 116 | 119 | |

| 0-CI || 19 | 3 | 16.36Kbps || 20 | 4 | 21.91Kbps | 518 | 664 | |

| 0-NI3 || 1174 | 234 | 4.56Mbps || 157 | 31 | 83.96Kbps | 2408 | 314 | |

| 0-NI2 || 1842 | 368 | 9.62Mbps || 1388 | 277 | 7.72Mbps | 3245 | 3456 | . |

| 0-NI1 || 309 | 61 | 193.56Kbps || 487 | 97 | 294.33Kbps | 371 | 357 | |

| 0-NI0 || 7805 | 1561 | 70.96Mbps || 6465 | 1293 | 17.83Mbps | 5662 | 1703 | . |

| 0-HI31 || 469 | 93 | 222.99Kbps || 403 | 80 | 1.96Mbps | 277 | 3020 | |

| 0-HI27 || 378 | 75 | 232.38Kbps || 302 | 60 | 985.84Kbps | 364 | 2020 | |

| 0-HI23 || 803 | 160 | 1.08Mbps || 750 | 150 | 4.04Mbps | 826 | 3349 | . |

| 0-HI19 || 1137 | 227 | 7.98Mbps || 1113 | 222 | 2.26Mbps | 4371 | 1250 | |

| 0-HI15 || 1313 | 262 | 1.41Mbps || 1368 | 273 | 5.56Mbps | 652 | 2520 | |

| 0-HI11 || 4985 | 997 | 15.10Mbps || 7179 | 1435 | 70.51Mbps | 1874 | 6119 | |

+--------++------------+-----------+------------++------------+-----------+------------+-------+-------+---+

fex-1#

Page 81: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

fex-1# show platform software woodside sts

(FINAL POSITION TBD) Uplink #: 1 2 3 4 5 6 7 8

Link status: | | | |

+-+--+--+--+--+--+--+--+-+

SFP: [$][$][$][$][ ][ ][ ][ ]

+-+--+--+--+--+--+--+--+-+

| N N N N N N N N |

| I I I I I I I I |

| 0 1 2 3 4 5 6 7 |

| |

| NI (0-7) |

+------------+-----------+

|

+-------------------------+-------------+-------------+---------------------------+

| | | |

+------------+-----------+ +-----------+------------+ +------------+-----------+ +-------------+----------+

| HI (0-7) | | HI (8-15) | | HI (16-23) | | HI (24-31) |

| | | | | | | |

| H H H H H H H H | | H H H H H H H H | | H H H H H H H H | | H H H H H H H H |

| I I I I I I I I | | I I I I I I I I | | I I I I I I I I | | I I I I I I I I |

| 0 1 2 3 4 5 6 7 | | 8 9 1 1 1 1 1 1 | | 1 1 1 1 2 2 2 2 | | 2 2 2 2 2 2 3 3 |

| | | 0 1 2 3 4 5 | | 6 7 8 9 0 1 2 3 | | 4 5 6 7 8 9 0 1 |

+-+--+--+--+--+--+--+--+-+ +-+--+--+--+--+--+--+--+-+ +-+--+--+--+--+--+--+--+-+ +-+--+--+--+--+--+--+--+-+

[ ][ ][ ][ ][ ][ ][ ][ ] [ ][ ][ ][ ][ ][ ][ ][ ] [ ][ ][ ][ ][ ][ ][ ][ ] [ ][ ][ ][ ][ ][ ][ ][ ]

+-+--+--+--+--+--+--+--+-+ +-+--+--+--+--+--+--+--+-+ +-+--+--+--+--+--+--+--+-+ +-+--+--+--+--+--+--+--+-+

: : - : - | - | - | - | - | - |

1 1 1 1 1 1 1 9 8 7 6 5 4 3 2 1

6 5 4 3 2 1 0

\__\__/__/ \__\__/__/ \__\__/__/ \__\__/__/ \__\__/__/ \__\__/__/ \__\__/__/ \__\__/__/

blade8 blade7 blade6 blade5 blade4 blade3 blade2 blade1

Page 82: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Pause framesfex-1# show platform software woodside rmon 0 HI31

+----------------------+----------------------+-----------------+----------------------+----------------------+-----------------+

| TX | Current | Diff | RX | Current | Diff |

+----------------------+----------------------+-----------------+----------------------+----------------------+-----------------+

| TX_PKT_LT64 | 0| 0| RX_PKT_LT64 | 0| 0|

| TX_PKT_64 | 1233122| 0| RX_PKT_64 | 299111| 0|

| TX_PKT_65 | 3443446179| 117| RX_PKT_65 | 1726497484| 67|

| TX_PKT_128 | 1468608090| 154| RX_PKT_128 | 678711943| 35|

| TX_PKT_256 | 164594394| 53| RX_PKT_256 | 257993274| 10|

| TX_PKT_512 | 140774947| 15| RX_PKT_512 | 202303546| 4|

| TX_PKT_1024 | 105217922| 0| RX_PKT_1024 | 76203194| 6|

| TX_PKT_1519 | 1371379821| 15| RX_PKT_1519 | 430787476| 19|

| TX_PKT_2048 | 520347482| 1| RX_PKT_2048 | 571391171| 6|

| TX_PKT_4096 | 163323927| 1| RX_PKT_4096 | 671897220| 115|

| TX_PKT_8192 | 2667845697| 1| RX_PKT_8192 | 3971350325| 34|

| TX_PKT_GT9216 | 0| 0| RX_PKT_GT9216 | 0| 0|

| TX_PKTTOTAL | 10046771581| 357| RX_PKTTOTAL | 8587434744| 296|

| TX_OCTETS | 29652413140776| 117300| RX_OCTETS | 42180807573683| 881346|

| TX_PKTOK | 10046771581| 357| RX_PKTOK | 8587434744| 296|

| TX_UCAST | 9475625210| 259| RX_UCAST | 8580251937| 294|

| TX_MCAST | 194696639| 43| RX_MCAST | 5884916| 2|

| TX_BCAST | 376449732| 55| RX_BCAST | 1297891| 0|

| TX_VLAN | 0| 0| RX_VLAN | 2| 0|

| TX_PAUSE | 0| 0| RX_PAUSE | 0| 0|

| TX_USER_PAUSE | 1233122| 0| RX_USER_PAUSE | 0| 0|

| TX_FRM_ERROR | 0| 0| | | |

| | | | RX_OVERSIZE | 0| 0|

| | | | RX_TOOLONG | 0| 0|

| | | | RX_DISCARD | 0| 0|

| | | | RX_UNDERSIZE | 0| 0|

| | | | RX_FRAGMENT | 0| 0|

| | | | RX_CRC_NOT_STOMPED | 0| 0|

| | | | RX_CRC_STOMPED | 0| 0|

| | | | RX_INRANGEERR | 0| 0|

| | | | RX_JABBER | 0| 0|

| TX_OCTETSOK | 29652413140776| 117300| RX_OCTETSOK | 42180807573683| 881346|

+----------------------+----------------------+-----------------+----------------------+----------------------+-----------------+

Page 83: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

UCS – south-bound trafficbdsol-6248-01-A(nxos)# show int fc1/31 counters

fc1/31

1 minute input rate 1698584 bits/sec, 212323 bytes/sec, 276 frames/sec

1 minute output rate 5050968 bits/sec, 631371 bytes/sec, 410 frames/sec

1538294716 frames input, 1586583115348 bytes

0 class-2 frames, 0 bytes

1538294716 class-3 frames, 1586583115348 bytes

0 class-f frames, 0 bytes

3 discards, 0 errors, 0 CRC

0 unknown class, 0 too long, 0 too short

1852810367 frames output, 2857726621688 bytes

0 class-2 frames, 0 bytes

1852810367 class-3 frames, 2857726621688 bytes

0 class-f frames, 0 bytes

0 discards, 0 errors

0 input OLS, 0 LRR, 0 NOS, 0 loop inits

0 output OLS, 0 LRR, 0 NOS, 0 loop inits

0 link failures, 0 sync losses, 0 signal losses

0 BB credit transitions from zero

16 receive B2B credit remaining

32 transmit B2B credit remaining

0 low priority transmit B2B credit remaining

Page 84: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

MDS / Nexus 5000bdsol-n5548-05# show int fc2/16 counters

fc2/16

1 minute input rate 608 bits/sec, 76 bytes/sec, 1 frames/sec

1 minute output rate 1008 bits/sec, 126 bytes/sec, 1 frames/sec

3676889 frames input, 215037652 bytes

0 discards, 0 errors, 0 CRC

0 unknown class, 0 too long, 0 too short

3573520 frames output, 335998936 bytes

0 discards, 0 errors

0 input OLS, 0 LRR, 0 NOS, 0 loop inits

2 output OLS, 3 LRR, 0 NOS, 0 loop inits

0 link failures, 0 sync losses, 0 signal losses

0 transmit B2B credit transitions from zero

0 receive B2B credit transitions from zero

16 receive B2B credit remaining

32 transmit B2B credit remaining

0 low priority transmit B2B credit remaining

bdsol-n5548-05#

Page 85: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Priority-flow-control

bdsol-n5548-05# show interface eth 1/3 priority-flow-control

============================================================

Port Mode Oper(VL bmap) RxPPP TxPPP

============================================================

Ethernet1/3 Auto On (8) 0 91568

bdsol-n5548-05# show running-config interface eth 1/3 | inc prio

bdsol-n5548-05# show running-config interface eth 1/3 all | inc priority-flow

priority-flow-control mode auto

High increase could indicate issue

PPP should be negotiated

Page 86: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

MDS / Nexus 5000 (NetApp connection)bdsol-9148-03# show int fc1/5 counters

fc1/5

5 minutes input rate 53824 bits/sec, 6728 bytes/sec, 7 frames/sec

5 minutes output rate 30504 bits/sec, 3813 bytes/sec, 4 frames/sec

1002260022 frames input, 1860761796076 bytes

0 class-2 frames, 0 bytes

1002260022 class-3 frames, 1860761796076 bytes

0 class-f frames, 0 bytes

0 discards, 0 errors, 0 CRC

0 unknown class, 0 too long, 0 too short

325808424 frames output, 533427696444 bytes

0 class-2 frames, 0 bytes

325808424 class-3 frames, 533427696444 bytes

0 class-f frames, 0 bytes

13 discards, 0 errors

0 input OLS, 1 LRR, 0 NOS, 1 loop inits

1 output OLS, 1 LRR, 0 NOS, 1 loop inits

0 link failures, 0 sync losses, 0 signal losses

200973 BB credit transitions from zero

32 receive B2B credit remaining

3 transmit B2B credit remaining

3 low priority transmit B2B credit remaining

bdsol-9148-03#

Page 87: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

NetApp – sysstat –x 1

CPU NFS CIFS HTTP Total Net kB/s Disk kB/s Tape kB/s Cache Cache CP CP Disk OTHER FCP iSCSI FCP kB/s iSCSI kB/s

in out read write read write age hit time ty util in out in out

81% 0 0 0 1040 0 1 433552 189136 0 0 0s 99% 99% Ff 100% 0 1040 0 94266 443486 0 0

76% 0 0 0 1132 1 1 468263 90818 0 0 0s 99% 100% :f 100% 0 1132 0 102386 488385 0 0

80% 0 0 0 1026 0 1 423101 116056 0 0 0s 99% 99% Ff 100% 0 1026 0 92862 438264 0 0

78% 0 0 0 1085 1 0 468863 80152 0 0 0s 98% 100% :f 100% 5 1080 0 100523 461375 0 0

74% 0 0 0 1079 0 1 463149 82334 0 0 0s 98% 100% :v 100% 5 1066 0 96791 464674 0 0

81% 0 0 0 1045 1 0 419688 144208 0 0 0s 98% 100% Bf 100% 0 1037 0 84566 426947 0 0

74% 0 0 0 1080 0 1 459704 128112 0 0 0s 98% 100% :f 100% 0 1080 0 90859 473043 0 0

79% 0 0 0 1061 1 0 464854 26593 0 0 1 99% 98% Fn 100% 0 1061 0 110116 454936 0 0

78% 0 0 0 1097 0 1 438281 192684 0 0 0s 98% 100% :f 100% 6 1075 0 98459 439136 0 0

76% 0 0 0 1104 1 0 478192 67437 0 0 0s 99% 100% :f 100% 0 1104 0 105721 485442 0 0

74% 0 0 0 1013 0 1 437082 71342 0 0 1 99% 100% Bs 100% 0 1013 0 68873 447389 0 0

77% 0 0 0 1088 1 1 457864 159100 0 0 0s 98% 100% :f 100% 0 1088 0 111044 453121 0 0

73% 0 0 0 1152 1 0 458688 49040 0 0 0s 99% 100% #v 100% 86 1066 0 98002 474682 0 0

79% 0 0 0 956 0 1 397356 180432 0 0 0s 98% 100% Bf 100% 9 947 0 92035 388960 0 0

76% 0 0 0 1109 1 1 458768 95284 0 0 0s 98% 100% :f 100% 0 1109 0 110914 477828 0 0

79% 0 0 0 939 1 0 413597 146458 0 0 0s 99% 86% Ff 100% 0 939 0 88678 403322 0 0

75% 0 0 0 1106 0 1 449017 91011 0 0 0s 98% 100% :f 100% 0 1106 0 104025 473335 0 0

73% 0 0 0 1027 1 0 476400 40699 0 0 1 98% 100% :v 100% 0 1027 0 93386 460589 0 0

76% 0 0 0 1022 0 1 415088 141152 0 0 0s 99% 100% Bf 100% 4 1018 0 84828 435949 0 0

74% 0 0 0 1042 1 0 459660 124908 0 0 0s 98% 100% :f 100% 0 1042 0 95839 455676 0 0

B Back to back CPs (CP generated CP) (The filer is having a tough time keeping up with writes)

F CP caused by full NVLog (one half of the nvram log was full, and so was flushed)

: continuation of CP from previous interval (means, A CP is still going on, during 1 second intervals)

Page 88: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

End-2-End network performance

Page 89: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• Follow traffic from Hypervisor UCS N5K/MDS ( NetApp)

End-2-End network performance

Page 90: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

• esxtop verify utilization / drop on VM and uplink

VMware

Page 91: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Nexus 1000V

• verify utilization / drop on VM (veth) and uplink (Eth) drops high CPU on VM or no resources

bdsol-vc01vsm-01# show int eth3/3

Ethernet3/3 is up

Hardware: Ethernet, address: 0050.5652.0a1f (bia 0050.5652.0a1f)

Port-Profile is Uplink

MTU 1500 bytes

Encapsulation ARPA

Port mode is trunk

full-duplex, 10 Gb/s

5 minute input rate 32376 bits/second, 30 packets/second

5 minute output rate 19496 bits/second, 7 packets/second

Rx

300248469 Input Packets 257907789 Unicast Packets

136066323 Multicast Packets 223171865 Broadcast Packets

99113994481 Bytes

Tx

128872308 Output Packets 123377360 Unicast Packets

550084 Multicast Packets 6369085 Broadcast Packets 5352056 Flood Packets

177730805977 Bytes

5696314 Input Packet Drops 0 Output Packet Drops

Page 92: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

bdsol-vc01vsm-01# show int Veth22

Vethernet22 is up

Port description is xd-vxme-d007, Network Adapter 1

Hardware: Virtual, address: 0050.569e.1755 (bia 0050.569e.1755)

Owner is VM "xd-vxme-d007", adapter is Network Adapter 1

Active on module 7

VMware DVS port 329

Port-Profile is VLAN_541

Port mode is access

5 minute input rate 496 bits/second, 0 packets/second

5 minute output rate 1872 bits/second, 1 packets/second

Rx

188297 Input Packets 916725 Unicast Packets

181987 Multicast Packets 248526 Broadcast Packets

69549471 Bytes

Tx

2957015 Output Packets 162803 Unicast Packets

14411526 Multicast Packets 6765942 Broadcast Packets 2789522 Flood Packets

316260141 Bytes

0 Input Packet Drops 0 Output Packet Drops

Page 93: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

UCS (vnic IOM FI north-bound)

bdsol-6248-01-B# show service-profile connectivity

Service Profile: DCNSOL-bdsol-esxi-04

vNIC: eth4

VIF ID Transport Fabric ID Status Prot Role Peer VIF ID Oper State

---------- --------- --------- ----------- ----------- ----------- ----------

894 Ether A Allocated Unprotected 0 Active

vNIC: eth5

VIF ID Transport Fabric ID Status Prot Role Peer VIF ID Oper State

---------- --------- --------- ----------- ----------- ----------- ----------

895 Ether B Allocated Unprotected 0 Active

Page 94: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

UCS

bdsol-6248-01-B# connect adapter 2/1/1

adapter 2/1/1 # connect

adapter 2/1/1 (top):3# attach-mcp

adapter 2/1/1 (mcp):2# vnic

---------------------------------------- --------- --------------------------

v n i c l i f v i f

id name type bb:dd.f state lif state uif ucsm idx vlan state

--- -------------- ------- ------- ----- --- ----- --- ----- ----- ---- -----

13 vnic_1 enet 08:00.0 UP 2 UP =>0 890 733 1 UP

14 vnic_2 enet 09:00.0 UP 3 UP =>1 891 731 1 UP

15 vnic_3 enet 0a:00.0 UP 4 UP =>0 892 734 1 UP

16 vnic_4 enet 0b:00.0 UP 5 UP =>1 893 732 1 UP

17 vnic_5 enet 0c:00.0 UP 6 UP =>0 894 735 1 UP

18 vnic_6 enet 0d:00.0 UP 7 UP =>1 895 733 1 UP

19 vnic_7 fc 0e:00.0 UP 8 UP =>0 896 736 1070 UP

20 vnic_8 fc 0f:00.0 UP 9 UP =>1 897 734 1080 UP

Page 95: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

adapter 2/1/1 (mcp):54# lifstats 7 -a

DELTA TOTAL DESCRIPTION

939 410692745 Tx unicast frames without error

0 5 Tx multicast frames without error

0 4125 Tx broadcast frames without error

518990 1923437369399 Tx unicast bytes without error

0 414 Tx multicast bytes without error

0 280500 Tx broadcast bytes without error

0 0 Tx frames dropped

0 0 Tx frames with error

19 153267420 Tx TSO frames

1349 344390451 Rx unicast frames without error

0 54 Rx multicast frames without error

0 76304 Rx broadcast frames without error

10188382 233574137276 Rx unicast bytes without error

0 4460 Rx multicast bytes without error

0 5188648 Rx broadcast bytes without error

0 0 Rx frames dropped

0 0 Rx rq drop pkts (no bufs or rq disabled)

0 0 Rx rq drop bytes (no bufs or rq disabled)

0 0 Rx frames with error

0 0 Rx good frames with RSS

0 0 Rx frames with Ethernet FCS error

0 4118 Rx frames len == 64

12 85808713 Rx frames 64 < len <= 127

64 230343441 Rx frames 128 <= len <= 255

1 3875981 Rx frames 256 <= len <= 511

4 914752 Rx frames 512 <= len <= 1023

4 247785 Rx frames 1024 <= len <= 1518

1264 23272019 Rx frames len > 1518

2.017Mbps Tx rate

38.310Mbps Rx rate

adapter 2/1/1 (mcp):55#

Page 96: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

fex-1# show platform software woodside rmon 0 HI31

+----------------------+----------------------+-----------------+----------------------+----------------------+-----------------+

| TX | Current | Diff | RX | Current | Diff |

+----------------------+----------------------+-----------------+----------------------+----------------------+-----------------+

| TX_PKT_LT64 | 0| 0| RX_PKT_LT64 | 0| 0|

| TX_PKT_64 | 1233122| 0| RX_PKT_64 | 299111| 0|

| TX_PKT_65 | 3443446179| 117| RX_PKT_65 | 1726497484| 67|

| TX_PKT_128 | 1468608090| 154| RX_PKT_128 | 678711943| 35|

| TX_PKT_256 | 164594394| 53| RX_PKT_256 | 257993274| 10|

| TX_PKT_512 | 140774947| 15| RX_PKT_512 | 202303546| 4|

| TX_PKT_1024 | 105217922| 0| RX_PKT_1024 | 76203194| 6|

| TX_PKT_1519 | 1371379821| 15| RX_PKT_1519 | 430787476| 19|

| TX_PKT_2048 | 520347482| 1| RX_PKT_2048 | 571391171| 6|

| TX_PKT_4096 | 163323927| 1| RX_PKT_4096 | 671897220| 115|

| TX_PKT_8192 | 2667845697| 1| RX_PKT_8192 | 3971350325| 34|

| TX_PKT_GT9216 | 0| 0| RX_PKT_GT9216 | 0| 0|

| TX_PKTTOTAL | 10046771581| 357| RX_PKTTOTAL | 8587434744| 296|

| TX_OCTETS | 29652413140776| 117300| RX_OCTETS | 42180807573683| 881346|

| TX_PKTOK | 10046771581| 357| RX_PKTOK | 8587434744| 296|

| TX_UCAST | 9475625210| 259| RX_UCAST | 8580251937| 294|

| TX_MCAST | 194696639| 43| RX_MCAST | 5884916| 2|

| TX_BCAST | 376449732| 55| RX_BCAST | 1297891| 0|

| TX_VLAN | 0| 0| RX_VLAN | 2| 0|

| TX_PAUSE | 0| 0| RX_PAUSE | 0| 0|

| TX_USER_PAUSE | 1233122| 0| RX_USER_PAUSE | 0| 0|

| TX_FRM_ERROR | 0| 0| | | |

| | | | RX_OVERSIZE | 0| 0|

| | | | RX_TOOLONG | 0| 0|

| | | | RX_DISCARD | 0| 0|

| | | | RX_UNDERSIZE | 0| 0|

| | | | RX_FRAGMENT | 0| 0|

| | | | RX_CRC_NOT_STOMPED | 0| 0|

| | | | RX_CRC_STOMPED | 0| 0|

| | | | RX_INRANGEERR | 0| 0|

| | | | RX_JABBER | 0| 0|

| TX_OCTETSOK | 29652413140776| 117300| RX_OCTETSOK | 42180807573683| 881346|

+----------------------+----------------------+-----------------+----------------------+----------------------+-----------------+

fex-1#

Page 97: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

fex-1# show platform software woodside rate

+--------++------------+-----------+------------++------------+-----------+------------+-------+-------+---+

| Port || Tx Packets | Tx Rate | Tx Bit || Rx Packets | Rx Rate | Rx Bit |Avg Pkt|Avg Pkt| |

| || | (pkts/s) | Rate || | (pkts/s) | Rate | (Tx) | (Rx) |Err|

+--------++------------+-----------+------------++------------+-----------+------------+-------+-------+---+

| 0-BI || 19 | 3 | 4.01Kbps || 11 | 2 | 2.20Kbps | 112 | 105 | |

| 0-CI || 49 | 9 | 17.28Kbps || 35 | 7 | 18.68Kbps | 200 | 313 | |

| 0-NI3 || 2028 | 405 | 9.25Mbps || 389 | 77 | 755.09Kbps | 2833 | 1193 | |

| 0-NI2 || 1898 | 379 | 11.20Mbps || 1549 | 309 | 6.91Mbps | 3671 | 2771 | . |

| 0-NI1 || 415 | 83 | 602.80Kbps || 4829 | 965 | 21.45Mbps | 887 | 2756 | |

| 0-NI0 || 15340 | 3068 | 99.12Mbps || 13169 | 2633 | 56.88Mbps | 4018 | 2679 | . |

| 0-HI31 || 4974 | 994 | 21.77Mbps || 2117 | 423 | 5.86Mbps | 2715 | 1712 | |

| 0-HI27 || 765 | 153 | 874.20Kbps || 742 | 148 | 4.58Mbps | 694 | 3846 | |

| 0-HI23 || 468 | 93 | 229.40Kbps || 348 | 69 | 2.22Mbps | 286 | 3978 | . |

| 0-HI19 || 1047 | 209 | 6.24Mbps || 959 | 191 | 2.06Mbps | 3705 | 1327 | |

| 0-HI15 || 3530 | 706 | 33.94Mbps || 2505 | 501 | 5.09Mbps | 5990 | 1252 | |

| 0-HI11 || 9994 | 1998 | 23.14Mbps || 12982 | 2596 | 100.38Mbps | 1427 | 4812 | |

+--------++------------+-----------+------------++------------+-----------+------------+-------+-------+---+

fex-1#

• bdsol-6248-01-B(nxos)# show int vethernet 895

• bdsol-6248-01-B(nxos)# show pinning interface vethernet 895

• bdsol-6248-01-B(nxos)# show interface port-channel 1

Page 98: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Nexus 5548

bdsol-n5548-05# show interface Eth1/31 | inc err

219107 input error 0 short frame 0 overrun 0 underrun 0 ignored

0 output errors 0 collision 0 deferred 0 late collision

bdsol-n5548-05# show interface Eth1/31 | inc CRC

0 runts 0 giants 38 CRC 0 no buffer

bdsol-n5548-05#

Page 99: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Upgrade the stack

Page 100: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Upgrade from FlexPOD VMware CVD 5.1 to CVD 5.5

FlexPOD VMware 5.1 FlexPOD VMware 5.5

UCS-B 2.1(3) 2.2(2c)

5548 6.0(2)N1(2a) 7.0(1)N1(1)

NetApp 8.2P4 8.2.1

VMware 5.1U1 5.5U1

Nexus 1000V 4.2(1)SV2(2.1a) .4.2(1)SV2(2.2)

Page 101: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

How do we start ?

• Check all upgrade guides

• List all steps to upgrade 1 component

• Look for prerequisites

• Find a matching sequence

Page 102: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

All steps

• UCS:

• Upgrade UCS Manager

• Update IO modules

• Activate IO modules set startup version

• Activate subordinate fabric interconnect

• Manually fail-over primary FI to upgrade FI, upgrade remaining FI

• Update / Activate Adapters / CIMC / BIOS / Storage controller

• VMware

• Upgrade vCenter

• Upgrade ESXi (do not upgrade VEM)

• Upgrade enic / fnic drivers

• NetApp:

– Upgrade controller A

– Upgrade controller B

• Nexus 5548

– Upgrade switch A

– Upgrade switch B

• Nexus 1000v

– Upgrade VSM

– Upgrade all VEM’s

Page 103: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Minimum requirements – Can we first upgrade Vmware to 5.5U1 ?

• Nexus 1000V - 4.2(1)SV2(2.1a) and 4.2(1)SV2(2.2)

• support VMware 5.5U1

• UCS - 2.1(3) and 2.2(2c)

• support VMware 5.5 U1

• NetApp - 8.2(P4) and 8.2.1

• support VMware 5.5 U1

• support UCS 2.1(3) and 2.2(2c)

• Nexus 5548 - 6.0(2)N1(2a) and 7.0(1)N1(1)

• support VMware 5.5U1

• Support UCS 2.1(3) and 2.2(2c)

Page 104: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Possible upgrade scenario

• Upgrade vCenter ESXi

• Block VEM upgrade

• Make custom ISO with eniv/fnic drivers

• Use enic/fnic drivers from UCS 2.1(3)

• Upgrade VSM Upgrade VEM

• Upgrade UCS

• After upgrading adapters upgrade VMware enic/fnic drivers• Make sure to upgrade blade per blade

• Upgrade Nexus 5548

• Upgrade NetAppAny moment

Page 105: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

UCS-Director automation

Page 106: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

UCS-Director automation

• UCS Director can automate day2day tasks of running a FlexPOD stack

• Deploy ESXi Host with ONTAP

• ACI / NetApp – new tenant on-boarding

• All common NetApp / UCS / VMware / Storage networking / … taks

Page 107: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf
Page 108: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Key take-aways

Page 109: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Key take-aways

• Carefully review all requirements and configure them across the stack

• When troubleshooting, use a top-down approach

• Make an inventory of all paths involved

• Understand all CRC’s, errors, speed of the entire path

• Upgrade the infrastructure step-by-step and make sure to understand all upgrade guides / pre-requisites

• UCS-Director can assist in automating standard deployment tasks

Page 110: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Participate in the “My Favorite Speaker” Contest

• Promote your favorite speaker through Twitter and you could win $200 of Cisco Press products (@CiscoPress)

• Send a tweet and include

• Your favorite speaker’s Twitter handle @rsmeyers

• Two hashtags: #CLUS #MyFavoriteSpeaker

• You can submit an entry for more than one of your “favorite” speakers

• Don’t forget to follow @CiscoLive and @CiscoPress

• View the official rules at http://bit.ly/CLUSwin

Promote Your Favorite Speaker and You Could Be a Winner

Page 111: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Complete Your Online Session Evaluation

Don’t forget: Cisco Live sessions will be available for viewing on-demand after the event at CiscoLive.com/Online

• Give us your feedback to be entered into a Daily Survey Drawing. A daily winner will receive a $750 Amazon gift card.

• Complete your session surveys though the Cisco Live mobile app or your computer on Cisco Live Connect.

Page 112: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Continue Your Education

• Demos in the Cisco campus

• Walk-in Self-Paced Labs

• Table Topics

• Meet the Engineer 1:1 meetings

• Related sessions

Page 113: Deploying FlexPod - clnv.s3.   bdsol-vc01vsm-01# show running-config | inc jumbo ... ESX Discovery in Fabric (with Blade Switch) For Dynamic download of policies to Leaf

Thank you