XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 1 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
XENTRY Update Service
Without Retail Data Storage
for XENTRY Kit | Kit 2
Mercedes-Benz AG, GSP/ORE
Valid from Release Update 11/2019
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 2 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
Contents
1. Preparing a USB storage medium ....................................................................................................................... 3
2. Configuration of the XENTRY Kit | Kit 2 ............................................................................................................. 4
3. Downloading the release update onto the XENTRY Tab | Tab 2 / standard PC .............................................. 8
4. Installing the release update ............................................................................................................................. 12
4.1. Installing the release update on the XENTRY Connect .................................................................... 12
4.2. Installing the release update on the XENTRY Tab | Tab 2 / standard PC ........................................ 13
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 3 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
1. Preparing a USB storage medium
Please prepare a blank USB storage medium. It must have a storage capacity of at least 128 GB.
Please plug the USB flash drive into the XENTRY Tab | Tab 2 / standard PC and wait a moment until it is detected by the
system.
Now open Windows Explorer, right-click on your USB storage medium and select the "Format" item.
This opens the following window:
Select the file system NTFS.
Please note:
The USB update function only supports NTFS as the file system. – The file systems of FAT, FAT32, and exFAT cannot be
used.
You might have to confirm a dialog notifying you that all data will be deleted during formatting of the data storage
medium.
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 4 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
2. Configuration of the XENTRY Kit | Kit 2
First make sure that you have loaded all current add-ons onto both your XENTRY Tab and your XENTRY Connect.
1. Launch XENTRY Control via the shortcut on the desktop of your XENTRY Tab / standard PC:
2. You will see the following home screen. Select the menu item "Configuration".
3. In the window that now opens, click on "Expert configuration".
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 5 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
4. Confirm the warning that appears by clicking on "Continue".
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 6 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
5. Select the following path:
XENTRY Tab / Standard PC > XENTRY Update Service > Without Retail Data Storage
The click on "Check connection".
6. If the check is successful, the connection is confirmed with a green tick.
Now select the button "Apply configuration to XENTRY Tab/standard PC".
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 7 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
7. The next window confirms the configuration to you:
Close the window by clicking on "Finished".
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 8 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
3. Downloading the release update onto the XENTRY Tab |
Tab 2 / standard PC
Now launch "XENTRY Update Service Control Center" via the windows Start menu on your XENTRY Tab / standard PC in
the "Mercedes-Benz" area.
Change to the "Release Overview" tab. The download of the release is displayed immediately.
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 9 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
When the download has finished, the XENTRY Update Service Control Center displays the complete download.
Now click on "Export" and export the release and the meta file. Save the files on the hard drive of your XENTRY
Tab/standard PC.
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 10 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
When you have saved them, there will be a zip archive and a meta file on your hard drive.
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 11 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
Extract the zip archive and copy all the files from the extracted zip archive and the *.meta file to the top level
of a USB storage medium.
You should see the following on the USB storage medium:
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 12 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
4. Installing the release update
4.1. Installing the release update on the XENTRY Connect
Please note: The XENTRY Connect must be in standby mode to install the release update. You can shut down the XENTRY
Connect directly on the device via the menu (gearwheels button) or from the XENTRY Control session.
Connect the power supply unit to the XENTRY Connect and insert the USB data storage medium into a free USB port of
the XENTRY Connect.
Now start the update mode of the XENTRY Connect by simultaneously pressing the two "red cross" and "green tick"
buttons.
Once "Start update" appears on the display, confirm this with the green tick. The update procedure starts. This will be
indicated as follows on the XENTRY Connect display:
The USB update takes about 70 minutes. The XENTRY Connect indicates when the update is finished on the display.
You can complete the process by pressing the "gearwheels" button. Or, wait until the XENTRY Connect automatically
shuts down (approx. 10 minutes after the picture appears on the display).
XENTRY Update Service without Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 13 of 13
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
4.2. Installing the release update on the XENTRY Tab | Tab 2 / standard
PC
Now insert the USB flash drive into a free USB port of your XENTRY Tab | Tab 2 / standard PC.
Run the "start.exe" file. The Update Wizard starts.
After the update procedure is completed successfully, you can exit the Wizard and your device is ready for use.