www.itw-industry.com
HIGH PERFORMANCE WALL STUD
ALPINE
WALL STUD SYSTEM MANUAL
Cl/SfB i1
July 2011
21 M2
Contents
SpaceStud overview
SpaceStud clip installation & typical wall make up
Key benefits of the SpaceStud system
Insulation options
Technical information
Technical details
Section through closed panel construction
Section through open panel construction
Panel joint (open panel construction)
SpaceStud to internal non-loadbearing partition joint
SpaceStud to internal load bearing partition joint
Internal corner panel joint (a)
Internal corner panel joint (b)
SpaceStud to twin soleplate connection (open panel)
SpaceStud to single soleplate connection (open panel)
Cripple SpaceStud at window opening
Floor to wall junction (no head binder)
Floor to wall junction (twin head binder)
Floor to wall junction (top hung joist)
Lintol over opening (a)
Lintol over opening (b)
Framing to window opening
Single soleplate
Twin soleplate
Closed panel
Enhanced bottom rail connection
04
05
06
06
07
08
09
09
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
Members of the UK Timber Frame Association
Members of the Trussed Rafter Association
Members of the UK SIP Association
Illinois Tool Works Inc. (NYSE: ITW) is a diversified manufacturing
company with nearly 100 years of history in delivering specialised
expertise, innovative thinking and value-added products to meet critical
customer needs in a variety of industries. ITW has decentralised business
units in 57 countries that employ approximately 61,000 men and women.
These talented individuals, many of whom have specialised engineering
or scientific expertise, contribute to our global leadership in innovation.
We are proud of our broad portfolio of more than 19,000 global patents
and patent applications.
ITW Industry, a division of Illinois Tool Works (ITW), specialises in products
and services for the timber construction industry - offering a complete
package including software, components, fasteners and equipment.
Software
ITW Industry develops and supports Alpine roof truss & floor joist
engineering software, Autodesk based hsbCAD 3D CAD / CAM and
VisionREZ architectural software. All of which combine under the ITW
Instinct Residential Design System.
Components
ITW Industry supplies a range of Alpine nailplate and Cullen engineered
timber connector products which are specified by the Alpine engineering
software for particular uses within the roof truss, floor joist & timber frame
industry.
Fasteners
ITW Industry is a leading supplier of a variety of powered fastening
systems including: pneumatic, gas and powder actuated from the
Paslode, Duo-Fast, Haubold and SPIT brands.
Equipment
ITW Industry supplies, installs and services automated fastening tools
(Toolmatic), roof truss & floor joist production machinery and scaffold
security & maintenance equipment.
Contents
SpaceStud overview
SpaceStud clip installation & typical wall make up
Key benefits of the SpaceStud system
Insulation options
Technical information
Technical details
Section through closed panel construction
Section through open panel construction
Panel joint (open panel construction)
SpaceStud to internal non-loadbearing partition joint
SpaceStud to internal load bearing partition joint
Internal corner panel joint (a)
Internal corner panel joint (b)
SpaceStud to twin soleplate connection (open panel)
SpaceStud to single soleplate connection (open panel)
Cripple SpaceStud at window opening
Floor to wall junction (no head binder)
Floor to wall junction (twin head binder)
Floor to wall junction (top hung joist)
Lintol over opening (a)
Lintol over opening (b)
Framing to window opening
Single soleplate
Twin soleplate
Closed panel
Enhanced bottom rail connection
04
05
06
06
07
08
09
09
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
Members of the UK Timber Frame Association
Members of the Trussed Rafter Association
Members of the UK SIP Association
Illinois Tool Works Inc. (NYSE: ITW) is a diversified manufacturing
company with nearly 100 years of history in delivering specialised
expertise, innovative thinking and value-added products to meet critical
customer needs in a variety of industries. ITW has decentralised business
units in 57 countries that employ approximately 61,000 men and women.
These talented individuals, many of whom have specialised engineering
or scientific expertise, contribute to our global leadership in innovation.
We are proud of our broad portfolio of more than 19,000 global patents
and patent applications.
ITW Industry, a division of Illinois Tool Works (ITW), specialises in products
and services for the timber construction industry - offering a complete
package including software, components, fasteners and equipment.
Software
ITW Industry develops and supports Alpine roof truss & floor joist
engineering software, Autodesk based hsbCAD 3D CAD / CAM and
VisionREZ architectural software. All of which combine under the ITW
Instinct Residential Design System.
Components
ITW Industry supplies a range of Alpine nailplate and Cullen engineered
timber connector products which are specified by the Alpine engineering
software for particular uses within the roof truss, floor joist & timber frame
industry.
Fasteners
ITW Industry is a leading supplier of a variety of powered fastening
systems including: pneumatic, gas and powder actuated from the
Paslode, Duo-Fast, Haubold and SPIT brands.
Equipment
ITW Industry supplies, installs and services automated fastening tools
(Toolmatic), roof truss & floor joist production machinery and scaffold
security & maintenance equipment.
04/05
ALPINE | SPACESTUD WALL STUD SYSTEM MANUALALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
SpaceStud overview
The innovative Alpine SpaceStud system from
ITW Industry has been specifically developed
to meet the thermal requirements of the
Building Regulations and the Code for
Sustainable Homes.
The Code is the national standard for the sustainable
design and construction of new homes. The Code aims
to reduce our carbon emissions and create homes that
are more sustainable.
The Code measures the sustainability of a new home
against nine categories of sustainable design, rating the
'whole home' as a complete package. A one to six star
rating system communicates the overall sustainability
performance of a new home. The Code sets minimum
standards for energy and water use at each level.
Scottish Building Standard 2010, section 6.1.2, have
given target U-values for walls of 0.19 and a maximim
wall u-value of 0.25.
Code
level
1
2
3
4
5
6
Current energy
standard (percentage
improvement over
2006 Part L)
10%
18%
25%
44%
100% regulated
emissions
Zero carbon onsite -
100% onsite plus
appliances (equivalent
to approximately 150%
in total)
TABLE: REGULATORY STEPS TO
ZERO CARBON & CORRESPONDING CODE LEVELS
When
change to
regulations
takes place
-
-
2010
2013
-
2016
2009 Code
consultation
proposals (%
improvement
over 2006 Part L)
25%
25%
25%
44%
70% onsite + 30%
allowable solutions
“Zero Carbon
Home” - 70%
onsite + allowable
solutions to reach
zero carbon
Product code
120051
120052
028502
Qty per box
600
500
440
Description
SpaceStud 55mm
SpaceStud 80mm
9-1703 (43 x 88mm A9 nailplate)
TABLE: BOX QUANTITIES
SpaceStud clip installation & typical wall make up
External
stud (mm)
63
63
63
63
89
89
Stud Spacer
(mm)
55
80
55
80
55
80
TABLE: STUD MAKE UP
Internal
stud (mm)
63
63
89
89
89
89
Total stud
width (mm)
181
206
207
232
233
258
The SpaceStud clip is pressed onto minimum C16 grade
timber with a 38mm minimum depth. Pressing must be
with a hydraulic press.
TYPICAL SPACESTUD WALL PANEL SECTION
External sheathing
9mm OSB3
Typical fixing pattern: Nail to external edges of sheathing at 150mm centres. Nail to internal studs at 300mm centres
Nail spec: Duo-Fast 2.9 x 50mm smooth shank nails (product code 312619)
Racking resistance of standard panel available upon request
Various top & bottom rail details are possible. This method shows loose 38 x 63 or 38 x 89 timbers
Timber blockTimber blocking piece plated between vertical studs using Alpine truss plates – minimum 140mm deep
SpaceStud connectors3 pairs of SpaceStud connectors, equally spaced (standard 2.4 – 2.5m high wall panel).
Note: Breather paper and insulation omitted for clarity
Plasterboard
SPACESTUD CLIP INSTALLATION
Nailplate43 x 88 A9
04/05
ALPINE | SPACESTUD WALL STUD SYSTEM MANUALALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
SpaceStud overview
The innovative Alpine SpaceStud system from
ITW Industry has been specifically developed
to meet the thermal requirements of the
Building Regulations and the Code for
Sustainable Homes.
The Code is the national standard for the sustainable
design and construction of new homes. The Code aims
to reduce our carbon emissions and create homes that
are more sustainable.
The Code measures the sustainability of a new home
against nine categories of sustainable design, rating the
'whole home' as a complete package. A one to six star
rating system communicates the overall sustainability
performance of a new home. The Code sets minimum
standards for energy and water use at each level.
Scottish Building Standard 2010, section 6.1.2, have
given target U-values for walls of 0.19 and a maximim
wall u-value of 0.25.
Code
level
1
2
3
4
5
6
Current energy
standard (percentage
improvement over
2006 Part L)
10%
18%
25%
44%
100% regulated
emissions
Zero carbon onsite -
100% onsite plus
appliances (equivalent
to approximately 150%
in total)
TABLE: REGULATORY STEPS TO
ZERO CARBON & CORRESPONDING CODE LEVELS
When
change to
regulations
takes place
-
-
2010
2013
-
2016
2009 Code
consultation
proposals (%
improvement
over 2006 Part L)
25%
25%
25%
44%
70% onsite + 30%
allowable solutions
“Zero Carbon
Home” - 70%
onsite + allowable
solutions to reach
zero carbon
Product code
120051
120052
028502
Qty per box
600
500
440
Description
SpaceStud 55mm
SpaceStud 80mm
9-1703 (43 x 88mm A9 nailplate)
TABLE: BOX QUANTITIES
SpaceStud clip installation & typical wall make up
External
stud (mm)
63
63
63
63
89
89
Stud Spacer
(mm)
55
80
55
80
55
80
TABLE: STUD MAKE UP
Internal
stud (mm)
63
63
89
89
89
89
Total stud
width (mm)
181
206
207
232
233
258
The SpaceStud clip is pressed onto minimum C16 grade
timber with a 38mm minimum depth. Pressing must be
with a hydraulic press.
TYPICAL SPACESTUD WALL PANEL SECTION
External sheathing
9mm OSB3
Typical fixing pattern: Nail to external edges of sheathing at 150mm centres. Nail to internal studs at 300mm centres
Nail spec: Duo-Fast 2.9 x 50mm smooth shank nails (product code 312619)
Racking resistance of standard panel available upon request
Various top & bottom rail details are possible. This method shows loose 38 x 63 or 38 x 89 timbers
Timber blockTimber blocking piece plated between vertical studs using Alpine truss plates – minimum 140mm deep
SpaceStud connectors3 pairs of SpaceStud connectors, equally spaced (standard 2.4 – 2.5m high wall panel).
Note: Breather paper and insulation omitted for clarity
Plasterboard
SPACESTUD CLIP INSTALLATION
Nailplate43 x 88 A9
Racking resistance
Improved racking resistance by approximately 20%
compared to a standard single sheathed 38 x 140mm
timber frame panel, determined from testing carried out
to BS EN594:1996. Tested with Alpine nailplate by a
UKAS accredited laboratory. Further information and
racking resistance available on request.
ALPINE | SPACESTUD WALL STUD SYSTEM MANUALALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
06/07
Technical information
External stud
width (mm)
63
63
89
89
Total SpaceStud
width (mm)
181
206
233
258
Wall U-Value (W/m².k) with
mineral wool insulation
0.20
0.19
0.17
0.16
Wall U-Value (W/m².k)
with PU insulation
0.15
0.13
0.13
0.11
Internal stud
width (mm)
63
63
89
89
Internal stud
separation (mm)
55
80
55
80
Tested by C4Ci. U-Values for different variations on the above wall constructions are available upon request
Exterior
Interior
Insulation type
Mineral wool
PU
U-Value (W/m².k)
0.038
0.023
102mm brick or block cladding
50mm normal cavity
Breather membrane
9mm OSB
SpaceStud (as per table above)
Vapour barrier
12.5mm plasterboard
THERMAL INFORMATION
Loading
Maximum transferrable surface wind pressure 9.02kN/m²
for studs at 600mm centres (characteristic).
13.5kN/m² for studs at 400mm centres (characteristic)
based on 3 pairs per 2.4m stud height.
Key benefits of the SpaceStud system
Code for Sustainable Housing
SpaceStud complies to The Code for Sustainable Homes
to level 4 and above.
Economical
SpaceStud is one of the most cost effective wall stud
systems on the market to comply to The Code for
Sustainable Homes to level 4 and above.
Thermal performance
SpaceStud creates the wall thicknesses required to
reduce U-values and thermal bridging compared to solid
timber.
No drilling or notching
Fast and simple installation of services, without the need
for drilling or notching.
Improved racking resistance
SpaceStud is 20% more resistant to racking than
standard 38 x 140mm timber frame.
Software flexibility
SpaceStud can be priced and detailed in ITW Industry’s
management and detailing packages AiMS, VIEW and
hsbCAD software.
UKTFA “Fabric First”
SpaceStud supports the UK Timber Frame Association’s
“Fabric First” campaign which highlights the benefits of
using timber frame as the core fabric of a building to
achieve higher levels of The Code for Sustainable
Homes.
Quality
NHBC stipulate treated timber must be used in wall stud
construction. SpaceStud is manufactured with standard
treated timber sizes.
LINEAR THERMAL TRANSMITTANCE (Psi value)W/m.K
Insulation value (λ)
0.023
0.030
0.040
Psi value (Ψ)
0.00677
0.00648
0.00310RACKING RESISTANCE
Wall construction
9mm OSB to front face only
9mm OSB to front and rear face
Resistance (kN/m)
2.27kN/m
3.77kN/m
(figures based on tests carried out to BS EN594:1996 without top load applied to panels)
INSULATION U-VALUESWALL CONSTRUCTION
Insulation options
U-values shown in this leaflet are based on generic insulation values. Improved values can be obtained by specifying
higher performing insulation from leading insulation manufacturers such as Rockwool, Knauf, Kingspan and Isover. Fill
or blown insulation systems on closed panels is also an option from insulation manufacturers such as Warmcel.
t : 0800 032 2555www.isover.co.uk
t : 08448 000135www.knaufinsulation.co.uk
t : 01544 388601www.insulation.kingspan.com
t : 08712 221780www.rockwool.co.uk
t : 01685 845200www.warmcel.co.uk
Racking resistance
Improved racking resistance by approximately 20%
compared to a standard single sheathed 38 x 140mm
timber frame panel, determined from testing carried out
to BS EN594:1996. Tested with Alpine nailplate by a
UKAS accredited laboratory. Further information and
racking resistance available on request.
ALPINE | SPACESTUD WALL STUD SYSTEM MANUALALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
06/07
Technical information
External stud
width (mm)
63
63
89
89
Total SpaceStud
width (mm)
181
206
233
258
Wall U-Value (W/m².k) with
mineral wool insulation
0.20
0.19
0.17
0.16
Wall U-Value (W/m².k)
with PU insulation
0.15
0.13
0.13
0.11
Internal stud
width (mm)
63
63
89
89
Internal stud
separation (mm)
55
80
55
80
Tested by C4Ci. U-Values for different variations on the above wall constructions are available upon request
Exterior
Interior
Insulation type
Mineral wool
PU
U-Value (W/m².k)
0.038
0.023
102mm brick or block cladding
50mm normal cavity
Breather membrane
9mm OSB
SpaceStud (as per table above)
Vapour barrier
12.5mm plasterboard
THERMAL INFORMATION
Loading
Maximum transferrable surface wind pressure 9.02kN/m²
for studs at 600mm centres (characteristic).
13.5kN/m² for studs at 400mm centres (characteristic)
based on 3 pairs per 2.4m stud height.
Key benefits of the SpaceStud system
Code for Sustainable Housing
SpaceStud complies to The Code for Sustainable Homes
to level 4 and above.
Economical
SpaceStud is one of the most cost effective wall stud
systems on the market to comply to The Code for
Sustainable Homes to level 4 and above.
Thermal performance
SpaceStud creates the wall thicknesses required to
reduce U-values and thermal bridging compared to solid
timber.
No drilling or notching
Fast and simple installation of services, without the need
for drilling or notching.
Improved racking resistance
SpaceStud is 20% more resistant to racking than
standard 38 x 140mm timber frame.
Software flexibility
SpaceStud can be priced and detailed in ITW Industry’s
management and detailing packages AiMS, VIEW and
hsbCAD software.
UKTFA “Fabric First”
SpaceStud supports the UK Timber Frame Association’s
“Fabric First” campaign which highlights the benefits of
using timber frame as the core fabric of a building to
achieve higher levels of The Code for Sustainable
Homes.
Quality
NHBC stipulate treated timber must be used in wall stud
construction. SpaceStud is manufactured with standard
treated timber sizes.
LINEAR THERMAL TRANSMITTANCE (Psi value)W/m.K
Insulation value (λ)
0.023
0.030
0.040
Psi value (Ψ)
0.00677
0.00648
0.00310RACKING RESISTANCE
Wall construction
9mm OSB to front face only
9mm OSB to front and rear face
Resistance (kN/m)
2.27kN/m
3.77kN/m
(figures based on tests carried out to BS EN594:1996 without top load applied to panels)
INSULATION U-VALUESWALL CONSTRUCTION
Insulation options
U-values shown in this leaflet are based on generic insulation values. Improved values can be obtained by specifying
higher performing insulation from leading insulation manufacturers such as Rockwool, Knauf, Kingspan and Isover. Fill
or blown insulation systems on closed panels is also an option from insulation manufacturers such as Warmcel.
t : 0800 032 2555www.isover.co.uk
t : 08448 000135www.knaufinsulation.co.uk
t : 01544 388601www.insulation.kingspan.com
t : 08712 221780www.rockwool.co.uk
t : 01685 845200www.warmcel.co.uk
Section through closed panel construction
Section through open panel construction
08/09
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
>TECHNICAL DETAILS
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Plasterboard
23 x 38mm vertical battens at 600mm centres (max) fitted to inside face of panel to form service void
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
9mm OSB pre-fitted to internal face of SpaceStuds
Vapour barrier to face of OSB
Plasterboard
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Vapour barrier to face of SpaceStud
Section through closed panel construction
Section through open panel construction
08/09
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
>TECHNICAL DETAILS
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Plasterboard
23 x 38mm vertical battens at 600mm centres (max) fitted to inside face of panel to form service void
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
9mm OSB pre-fitted to internal face of SpaceStuds
Vapour barrier to face of OSB
Plasterboard
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Vapour barrier to face of SpaceStud
10/11
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
SpaceStud to internal load bearing partition joint
Internal corner panel joint (a)
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
Panel joint (open panel construction)
SpaceStud to internal non-loadbearing partition joint
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Plasterboard
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Panels to be butted and nailed together at 300mm centres (preferred fixing Paslode IM90i & 3.1 x 75mm ring shank nail)
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Plasterboard
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation fitted between SpaceStuds on site prior to vapour barrier and plasterboard
Partition noggins nailed between SpaceStuds (preferred fixing Paslode IM90i & 3.1 x 75mm ring shank nail)
Internal non-load bearing partition nailed to noggins (preferred fixing Paslode IM90i & 3.1 x 90mm ringshank nails)
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Plasterboard
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Internal load bearing partition nailed to SpaceStuds (preferred fixing Paslode IM90i & 3.1 x 90mm ring shank nails)
Insulation fitted between SpaceStuds on site prior to vapour barrier and plasterboard
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard
Panels butted and nailed together at 300mm centres (preferred fixing Paslode IM90i & 3.1 x 90mm ring shank nails)
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Vertical flexi fire stop
9mm OSB pre-fitted to external face of SpaceStuds
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
10/11
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
SpaceStud to internal load bearing partition joint
Internal corner panel joint (a)
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
Panel joint (open panel construction)
SpaceStud to internal non-loadbearing partition joint
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Plasterboard
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Panels to be butted and nailed together at 300mm centres (preferred fixing Paslode IM90i & 3.1 x 75mm ring shank nail)
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Plasterboard
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation fitted between SpaceStuds on site prior to vapour barrier and plasterboard
Partition noggins nailed between SpaceStuds (preferred fixing Paslode IM90i & 3.1 x 75mm ring shank nail)
Internal non-load bearing partition nailed to noggins (preferred fixing Paslode IM90i & 3.1 x 90mm ringshank nails)
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Plasterboard
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Internal load bearing partition nailed to SpaceStuds (preferred fixing Paslode IM90i & 3.1 x 90mm ring shank nails)
Insulation fitted between SpaceStuds on site prior to vapour barrier and plasterboard
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard
Panels butted and nailed together at 300mm centres (preferred fixing Paslode IM90i & 3.1 x 90mm ring shank nails)
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
Vertical flexi fire stop
9mm OSB pre-fitted to external face of SpaceStuds
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
12/13
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
SpaceStud to single soleplate connection (open panel)
Cripple SpaceStud at window opening
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
Internal corner panel joint (b)
SpaceStud to twin soleplate connection (open panel)
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
9mm OSB pre-fitted to external face of SpaceStuds
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Panels butted together and nailed at 300mm centres (preferred fixing Paslode IM90i & 3.1 x 90mm ring shank nails)
Plasterboard to internal face of SpaceStuds
Insulation pre-fitted between SpaceStuds
102mm brick external leaf
50mm ventilated cavity
Cullen stainless steel ST-PFS-50 timber frame holding down strap (centres as per engineer’s requirements)
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Panels nailed to soleplate (preferred fixing Paslode IM90i & 3.1 x 75mm ring shank nails) Double soleplate fixed using
Tapcon screws or similar (as per engineer’s requirements)
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard to internal face of SpaceStuds
DPC under soleplate
102mm brick external leaf
50mm ventilated cavity
Cullen stainless steel ST-PFS-50 timber frame holding down strap (centres as per engineer’s requirements)
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Panels nailed to soleplate (preferred fixing Paslode IM90i & 3.1 x 75mm ring shank nails) Soleplate fixed using Tapcon
screws or similar (as per engineer’s requirements)
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard to internal face of SpaceStuds
DPC under soleplate
Single or double cripple SpaceStuds either side of openings as required
Plasterboard to internal face of SpaceStuds
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Vertical flexi fire stop
102mm brick external leaf
50mm ventilated cavity
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Vertical flexi fire stop
Breather membrane pre-fitted to face of OSB
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
12/13
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
SpaceStud to single soleplate connection (open panel)
Cripple SpaceStud at window opening
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
Internal corner panel joint (b)
SpaceStud to twin soleplate connection (open panel)
102mm brick external leaf
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
50mm ventilated cavity
9mm OSB pre-fitted to external face of SpaceStuds
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Panels butted together and nailed at 300mm centres (preferred fixing Paslode IM90i & 3.1 x 90mm ring shank nails)
Plasterboard to internal face of SpaceStuds
Insulation pre-fitted between SpaceStuds
102mm brick external leaf
50mm ventilated cavity
Cullen stainless steel ST-PFS-50 timber frame holding down strap (centres as per engineer’s requirements)
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Panels nailed to soleplate (preferred fixing Paslode IM90i & 3.1 x 75mm ring shank nails) Double soleplate fixed using
Tapcon screws or similar (as per engineer’s requirements)
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard to internal face of SpaceStuds
DPC under soleplate
102mm brick external leaf
50mm ventilated cavity
Cullen stainless steel ST-PFS-50 timber frame holding down strap (centres as per engineer’s requirements)
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Panels nailed to soleplate (preferred fixing Paslode IM90i & 3.1 x 75mm ring shank nails) Soleplate fixed using Tapcon
screws or similar (as per engineer’s requirements)
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard to internal face of SpaceStuds
DPC under soleplate
Single or double cripple SpaceStuds either side of openings as required
Plasterboard to internal face of SpaceStuds
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Vertical flexi fire stop
102mm brick external leaf
50mm ventilated cavity
Cullen FT-50 (or other to suit cavity width) timber to brick wall tie - centres to be specified by building designer
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Vertical flexi fire stop
Breather membrane pre-fitted to face of OSB
Horizontal flexi fire stop
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Floor to wall junction (top hung floor joist)
Lintol over opening (a)
14/15
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
Floor to wall junction (no head binder)
Floor to wall junction (twin head binder)
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
102mm brick external leaf
50mm ventilated cavity
Wall tie
Breather membrane pre-fitted to face of OSB
38 x 89 perimeter noggins
9mm OSB closer piece to joist
Horizontal flexi fire stop
Breather membrane pre-fitted to face of OSB
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard to internal face of SpaceStuds
Floor joist
102mm brick external leaf
50mm ventilated cavity
Wall tie
Breather membrane pre-fitted to face of OSB
LVL or Glulam edge binder
38 x 63 or 38 x 89mm head binder to SpaceStud panel
Horizontal flexi fire stop
Breather membrane pre-fitted to face of OSB
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard to internal face of SpaceStuds
Floor joist
102mm brick external leaf
50mm ventilated cavity
Wall tie
Breather membrane pre-fitted to face of OSB
47mm deep perimeter timber to match SpaceStud timbers
Breather membrane pre-fitted to face of OSB
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard to internal face of SpaceStuds
38 x 50mm timber noggin fitted between SpaceStuds to support edge of plasterboard
Floor joistHorizontal flexi fire stop
102mm brick external leaf
50mm ventilated cavity
Wall tie
Head binder to SpaceStud panel
Lintols within panel supported on cripple SpaceStuds and packed with insulation (to reduce thermal bridging)
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Vapour barrier to face of SpaceStud
Horizontal flexi fire stop
Vapour barrier to face of SpaceStud
Vapour barrier to face of SpaceStud
Floor to wall junction (top hung floor joist)
Lintol over opening (a)
14/15
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
Floor to wall junction (no head binder)
Floor to wall junction (twin head binder)
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
102mm brick external leaf
50mm ventilated cavity
Wall tie
Breather membrane pre-fitted to face of OSB
38 x 89 perimeter noggins
9mm OSB closer piece to joist
Horizontal flexi fire stop
Breather membrane pre-fitted to face of OSB
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard to internal face of SpaceStuds
Floor joist
102mm brick external leaf
50mm ventilated cavity
Wall tie
Breather membrane pre-fitted to face of OSB
LVL or Glulam edge binder
38 x 63 or 38 x 89mm head binder to SpaceStud panel
Horizontal flexi fire stop
Breather membrane pre-fitted to face of OSB
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard to internal face of SpaceStuds
Floor joist
102mm brick external leaf
50mm ventilated cavity
Wall tie
Breather membrane pre-fitted to face of OSB
47mm deep perimeter timber to match SpaceStud timbers
Breather membrane pre-fitted to face of OSB
206mm wide SpaceStud consisting of 38 x 63mm timber and 80mm pressed SpaceStud clip (also available in widths of 181 to 258mm wide)
Insulation pre-fitted between SpaceStuds
Plasterboard to internal face of SpaceStuds
38 x 50mm timber noggin fitted between SpaceStuds to support edge of plasterboard
Floor joistHorizontal flexi fire stop
102mm brick external leaf
50mm ventilated cavity
Wall tie
Head binder to SpaceStud panel
Lintols within panel supported on cripple SpaceStuds and packed with insulation (to reduce thermal bridging)
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Vapour barrier to face of SpaceStud
Twin soleplate
16/17
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
Lintol over opening detail (b)
Framing to window opening
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
102mm brick external leaf
50mm ventilated cavity
Wall tie
Head binder to SpaceStud panel
Horizontal flexi fire stop
Lintols within panel supported on cripple SpaceStuds and packed with insulation (to reduce thermal bridging)
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Lintols within panel supported on cripple SpaceStuds and packed with insulation (to reduce thermal bridging)
Full height SpaceStud
Single or double cripple SpaceStuds to support lintols
Single soleplate
Note: Breather paper and insulation omitted for clarity
Skirting board
Plasterboard
43 x 88mm A9 nailplate
Soleplate fixed to concrete foundation using SPIT fixing (eg. Tapcon)
Nail bottom rail to soleplate with 3.1 x 75mm ring shank nails using the Paslode IM90i cordless nailer
Note: Breather paper and insulation omitted for clarity
Skirting board
Plasterboard
43 x 88mm A9 nailplate
Double or single soleplates fixed to concrete foundation using SPIT fixing (eg. Tapcon)
Nail bottom rail to soleplate with 3.1 x 75mm ring shank nails using the Paslode IM90i cordless nailer
Twin soleplate
16/17
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
Lintol over opening detail (b)
Framing to window opening
ALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
102mm brick external leaf
50mm ventilated cavity
Wall tie
Head binder to SpaceStud panel
Horizontal flexi fire stop
Lintols within panel supported on cripple SpaceStuds and packed with insulation (to reduce thermal bridging)
Breather membrane pre-fitted to face of OSB
9mm OSB pre-fitted to external face of SpaceStuds
Lintols within panel supported on cripple SpaceStuds and packed with insulation (to reduce thermal bridging)
Full height SpaceStud
Single or double cripple SpaceStuds to support lintols
Single soleplate
Note: Breather paper and insulation omitted for clarity
Skirting board
Plasterboard
43 x 88mm A9 nailplate
Soleplate fixed to concrete foundation using SPIT fixing (eg. Tapcon)
Nail bottom rail to soleplate with 3.1 x 75mm ring shank nails using the Paslode IM90i cordless nailer
Note: Breather paper and insulation omitted for clarity
Skirting board
Plasterboard
43 x 88mm A9 nailplate
Double or single soleplates fixed to concrete foundation using SPIT fixing (eg. Tapcon)
Nail bottom rail to soleplate with 3.1 x 75mm ring shank nails using the Paslode IM90i cordless nailer
18/19
ALPINE | SPACESTUD WALL STUD SYSTEM MANUALALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
Closed panel
Enhanced base rail connection
Blocking pieces extended by depth of top and bottom rails and interlocked to provide an enhanced detail
Note: Breather paper and insulation omitted for clarity
Note: Breather paper and insulation omitted for clarity
9mm OSB3 sheathing
Exterior masonry
SpaceStud
9mm OSB3 sheathing
Cullen wall tie
Plasterboard
SpaceStud clip
Production machinery
A key benefit of the SpaceStud system is that it
can be manufactured on existing roof truss and
floor joist presses to optimise production.
However, ITW Industry can supply a dedicated
machine built in partnership with AV Birch to
free up other presses if required.
Features of the AV Birch Wall Stud Press:
�Press SpaceStuds in depths of up to 3m in length
�Entry level option up to full automation
�Large pressing platten with quick pressing time for
maximum productivity
HYDRAULIC
POWER PACKPLATTEN RUNS
IN CHANNELS
100 X 50
SPACESTUD
750
400
3000
mm FRA
MES
SPACESTUD BUILT
ON MOVING PLATTEN
PUSHED UNDER PRESS
WALL STUD PRESS DEMONSTRATED AT ECOBUILD
18/19
ALPINE | SPACESTUD WALL STUD SYSTEM MANUALALPINE | SPACESTUD WALL STUD SYSTEM MANUAL
Closed panel
Enhanced base rail connection
Blocking pieces extended by depth of top and bottom rails and interlocked to provide an enhanced detail
Note: Breather paper and insulation omitted for clarity
Note: Breather paper and insulation omitted for clarity
9mm OSB3 sheathing
Exterior masonry
SpaceStud
9mm OSB3 sheathing
Cullen wall tie
Plasterboard
SpaceStud clip
Production machinery
A key benefit of the SpaceStud system is that it
can be manufactured on existing roof truss and
floor joist presses to optimise production.
However, ITW Industry can supply a dedicated
machine built in partnership with AV Birch to
free up other presses if required.
Features of the AV Birch Wall Stud Press:
�Press SpaceStuds in depths of up to 3m in length
�Entry level option up to full automation
�Large pressing platten with quick pressing time for
maximum productivity
HYDRAULIC
POWER PACKPLATTEN RUNS
IN CHANNELS
100 X 50
SPACESTUD
750
400
3000
mm FRA
MES
SPACESTUD BUILT
ON MOVING PLATTEN
PUSHED UNDER PRESS
WALL STUD PRESS DEMONSTRATED AT ECOBUILD
A division of ITW Limited
Registered Office: Admiral HouseSt Leonard’s RdWindsorBerkshireSL4 3BL. Registered in England No. 559693
© ITW Industry 2011
No part of this publication may be reproduced without prior permission from ITW Industry.
Last updated: 01-11-2011
Customer Services (GB)
1 Wheatstone PlaceSouthfield Industrial EstateGlenrothesFifeKY6 2SWUnited Kingdom
t : +44(0)1592 771132f : +44(0)1592 771182e: [email protected]
Alpine/hsbCAD Technical Support
Threemilestone TruroCornwallTR4 9LDUnited Kingdom
t : +44(0)1872 245456f : +44(0)1872 245451e: [email protected]
www.itw-industry.com
Cullen Technical Support
1 Wheatstone PlaceSouthfield Industrial EstateGlenrothesFifeKY6 2SWUnited Kingdom
t : +44(0)1592 777570f : +44(0)1592 777575e: [email protected]
Customer Services (Ireland)
Kells Business Park Cavan RoadKellsCounty MeathIreland
t : +353(0)4692 93470/1f : +353(0)4692 93473e: [email protected]