USER'S MANUAL Split Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng

USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

Embed Size (px)

Citation preview

Page 1: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

USER'S MANUALSplit Floor-Standing Air Conditioner

Please read the user's manual carefully before using the product G

L17E

ng

Page 2: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

Foreword

Instructions to Users

Names and Functions of Various Parts

Use of Control Panel

Use of remote controller

Methods of Maintenance

Phenomena Diagnosis and Treatment

1

2

5

6

11

12

CONTENTS

Thank you for choosing our company products!Air conditioning facilities are valuable products. In order to protect your legitimate rights andinterests, please make sure that the installations are done by professional technicians. This Manualis a general-purpose version for the split floor-standing air conditioning systems manufactured byour Co., the one that you have chosen might be a little different in appearance from the onesdescribed in this Manual. But these differences will not have any impacts upon your operation anduse of the system.Please read the Manual carefully before you operate the system and check to see if the model isidentical to the one you have purchased. Keep this Manual properly in case you might refer to it inthe future.Addition to the user manual:The appliance is not intended for use by young children or infirm persons without supervision;Young children should be supervised to ensure that they do not play with the appliance.

Page 3: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

*INSTUCTIONS TO USERS*

1

Please read the Manual carefully before using the air conditioner so as to ensure the normal operations of the units.

USER'S MANUALSplit Floor-Standing Air Conditioner

NO!

I do thespraying!

I dodge!

Do not open the return-air grids of theindoor unit during operations.

Do not put the sticks or other similarobjects into the air inlet and outlet.

Do not place insecticides, paints orother inflammables near the inlet oroutlet; do not spray such articles directlyagainst the units.

The grounding terminal of the units mustbe well connected to the grounding of thepower source.

When doing the cleaning of the machine,do not splash water to the units.

Do not block the air inlet and outlet ofthe indoor or outdoor units so as to avoidpossible negative impacts upon themachine performances or hazards.

Re-start the operation after power failure Non-operation for long time

Never use copper wires to substitute thefuses, which might lead to operationalfaults or fire hazards.

If the machine is not in use for long time,the power source should be disconnectedfor the sake of safety and energy-saving.

When the power supply is resumed, the air conditionerwill automatically enter the standby mode. Press theOn/Off button to restart the operation.

In the case that the breaker is frequentlydisconnected, you should stop theoperation of the machine and contactthe dealer or our Co. authorizedmaintenance shop.

Indoor unit

Air deliveryblocked

Air inletblocked

Outdoor unit

It might result in faulty operations orelectric shocks and other hazards.

Air outletblocked Power leakage

protectionswitch

S K

Dangerous!

Copperwire

If the electric wires are damaged or need to bereplaced due to other reasons, please ask our Co.after-sale service person or the professionaltechnicians in the authorized maintenance shopsto do the replacement so as to avoid possible electricshock, overheating, fire hazards or other accidents.

When you restart the operation after along period of non-operation, you shouldcarefully check the air conditioner andthe wire connection.

Operate the machine only under thenominated voltage and frequency andwith corresponding protective devices.

MODE

Page 4: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

2

Indoor Unit

Outdoor Units

Air inlet

Air inlet

Air outlet

Air inlet

Air inlet

Air outlet

Features and appearance will vary.All the figure give a demonstration to introduce the function.

*NAMES AND FUNCTIONS OF VARIOUS PARTS*USER'S MANUALSplit Floor-Standing Air Conditioner

Up/down air direction guidesFor adjusting the vertical air deliverydirections

Air filter screen

Air outlet

For filtering dust and filth in the air

Control panel

Air filter gridsFor air inlet from the room air

Left/right air swinging finsFor adjusting horizontal air deliverydirections

Page 5: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

TIMING KEYTo press timing key to setturning on time,turning offtime and to cancel timing,the time range is 1-12hours.

SWINGING WINDSELECTION KEY

To choose different windtypes of swinging windorset wind by pressing thiskey.

WIND SPEEDSELECTION KEY

Press the key to choosethe wind speed and thewind speed changes in thefollowing order with eachpress:high,middle,low.

MODE SELECTION KEYPress the key to chooseoperation modes ofrefrigerating,dehumidifying,heating (orventilating for refrigeratingonly AC unit).

3

USER'S MANUALSplit Floor-Standing Air Conditioner

O p e r a t i o n P a n e l

RefrigeratingOperation Display

MODE

Defrosting OperationDisplay

Room settemperature andfailure code display

Timing Display

Display sign of fan

Heating (ventilating) operation display

Sleeping operation display

Dehumidifyingoperation display

Display lock-up function

Wind speed operation(swinging wind)display

one bright fan blade indicates low wind speed,two bright fan blade indicates middle wind speed,three bright fan blade indicates high wind speed,swinging fan blade indicates winging wind.

SLEEPING KEYPress the key to choosesleeping mode,the AC willoperate with low windspeed and automaticallyturns off after 8 hours,Press the key once againto cancel sleeping mode.

TEMPERATURE+ KEYPress the key once toincrease the settemperature by 10C,thehighest temperature is290C.

TEMPERATURE- KEYPress the key once toreduce the set temperatureby 10C,the lowesttemperature is 180C.

TURN ON/OFF KEYPress the key to turn on orturn off the AC unit.

(1)

Page 6: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

TIMING KEYTo press timing key to set turningon time,turning off time and tocancel timing,the time range is1-12 hours.

SWINGING WINDSELECTION KEY

To choose different windtypes of swinging windor setwind by pressing this key.

WIND SPEEDSELECTION KEY

Press the key to choose the windspeed and the wind speedchanges in the following orderwith each press:high,middle,low.

MODE SELECTION KEYPress the key to choose operationmodes of refrigerating,dehumidifying,heating (orventilating for refrigerating onlyAC unit).

4

h

MODE

(2)

Dehumidifying operation display

Refrigerating operation display

Display sign of fan

Room emperature display

Set temperature display

Display lock-up function

Swinging wind operation display

Heating (ventilating) operation display

High,Middle and low wind speed operation displayone bright fan blade indicates low wind speed,two bright fan blade indicates middle wind speed,three bright fan blade indicates high wind speed,swinging fan blade indicates winging wind.

Timing display

Sleeping operation display

Defrosting operation display

TURN ON/OFF KEYPress the key to turn on orturn off the AC unit.

TEMPERATURE+ KEYPress the key once toincrease the settemperature by 10C,thehighest temperature is290C.

TEMPERATURE- KEYPress the key once toreduce the set temperatureby 10C,the lowesttemperature is 180C.

SLEEPING KEYPress the key to choose sleepingmode,the AC will operate with lowwind speed and automaticallyturns off after 8 hours,Press thekey once again to cancel sleepingmode.

Specification:* Usually,the display screen shows only the function mode and operation status you choose.* When room temperature equals to or is lower than 180C,the function of dehumidifying cannot be used.* When room temperature equals to or is lower than set temperature,the AC unit stops for a period of time to save energy.* The AC unit is equipped with automatic defrosting function and the defrosting operation display on the display screen is bright when the machinedefrosts.* The AC unit with heat pump has auxiliary electric heating function,which will automatically turns on or off according to room temperature duringheating operation to achieve the best heating result.* If you turn on the machine immediately after it is turned off,the machine with time-lapse starting function will automatically turns on the machineafter 3 minutes to protect it.

Note:the position and arrangement of keys in different models and different types of AC might vary,but the keys with same name have the same function.

O p e r a t i o n P a n e l

USER'S MANUALSplit Floor-Standing Air Conditioner

Page 7: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

Set turning on timeSet the time for the unit to turn on and when it is time,the AC will automatically start operating.

Steps of setting turning on time1. When AC is working,press the key of and the machine is in the timing status of turning on;2. Press the key of continuously to reach the turning on time you want within a time range of 1-12 hours;five seconds later,themachine is in the timing status of turning on;3. After the turning on time is set,the AC unit will automatically turn on at your set time;4. To cancel the timing,press the key of continuously till 12 is displayed,one more press and the timing is cancelled;

*USE OF CONTROL PANEL*

5

USER'S MANUALSplit Floor-Standing Air Conditioner

Change wind direction

Timing operation

Set turning off timeSet the time for the unit to turn off and when it is time,the AC will automatically stop operating.

Steps of setting turning off time1. When AC is working,press the key of and the machine is in the timing status of turning off;2. Press the key of continuously to reach the turning off time you want within a time range of 1-12 hours;five seconds later,themachine is in the timing status of turning off;3. After the turning off time is set,the AC unit will automatically turn off at your set time;4. To cancel the timing,press the key of continuously till 12 is displayed,one more press and the timing is cancelled;when themachine is working,only timing turning off function is functional.

Operation of Mode change between Refrigerating/Dehumidifying/Heating/Ventilating

MODE

1.Press on/off key2. Press mode key to choose the mode you wantWhen you choose ventilating mode,the compressor does not work.

3.Press temperature +/- key to set the room temperature youwantThe room temperature range is 180C-290C.

4. Press the key of wind speed to set the speed you want fromhigh through middle to lowThe fan operates in low speed under the mode of dehumidifying

5.Press the key of swinging wind to change wind direction6.Press on/off key once again to stop.If you turn on the machine immediately ofter it is turned off,the machinewith time-lapse starting function will automatically turns on the machineafter 3 minutes to protect it.

Change Left/Right Wind DirectionPress wind swinging key,the screen will display swinging wind blade,which changes winddirection by swinging from left to right.

Set wind directionWhen wind blade reaches the position you desire,press wind swinging key again to stop theblade for a set wind direction.

Change up/down wind directionHold both ends of wind guide panel to change the wind sending angle.

h

Page 8: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

*USE OF REMOTE CONTROLLER*

6

* Above figure shows all indications for the purpose of explanation,but practically only the pertinent.

NOTE: Please check to refer the instructions for the identical remote controller of your air-conditioner.

USER'S MANUALSplit Floor-Standing Air Conditioner

HOUR

SWING buttonPress this button to select theleft/right swinging of air delivery orto stop swinging.

SLEEP buttonThis button changes to SLEEPoperation,press again to cancelthe sleep operotion.

AM PM

ON/OFF

+ -

MODE

FAN SPEED

TIMER MIN

SLEEP

SWINGHOLD

HON-TIMER

OFF-TIMER

Fan Speed Selection buttonPress this button to select the highspeed,med-speed or low speedof air delivery.

HOLD buttonPress this button to lock orunlock the keyboard.

Temperature Setting buttonThis button is used to set the roomtemperature.Each pressing of the " " or " " button,thetemperature setting is increasedor decreased by 10C.

+ -

TIMER buttonThis button is used to set theswitch-on or switch-off time. Usedtogether with the "HOUR" button,the time setting can be madewithin the range of 1-12 hours,with the interval of one hour. Time Setting button

This button is used to set the currenttime or the time for timed switch-onof switch-off.

ON/OFF buttonPress this button will start theoperations of the units.Press it onceagain will stop the operations.

Air flow indicator

Signal transmitting section.

Operation Mode buttonThis button is used to select thecooling,heating,or dehumidificationmode of operation.sequence of mode switch is cooling-dehumidification-heating.

(For the cooling-only models, the"Heating" mode is for FAN).

Operation mode indictor

Fan speed indicator

Time indicator

Temperature indicator

Indicates the set temperature

Lock key indicator

Timed time indicator

Sleep mode indicator

LAMP buttonPress this button to make the lampof control panel lights on or off.

LAMP

Remote controller 1

Page 9: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

7

USER'S MANUALSplit Floor-Standing Air Conditioner

This remote controller is the general one of our company,it can be used for many types of our air-conditioners. We beg your forgiveness that we would not introduce the button or indicator which is notapplicable for the units you purchased.

Sleeping indicator

Temperature indicatorindicates set temperature.

Swinging indicator

Fan speed indicator

Lock key indicator

Timed time orcurrent time indicator

Cooling indicator

Dehumidifying indicator

Heating indicator

Faning indicator

TEMP SETTING buttonEach pressing of the button, thetemperature setting is increasedby 1˚C

SWING buttonPress this button to select the left/rightswinging of air delivery or to stop swinging.

FAN SPEED buttonPress this button to select the high speed,mid-speed or low speed of air delivery.

TIMER buttonThis button is used to set the switch-on orswitch-off time. Used together with the"HOUR" button,the time setting can be madewithin the range of 1-12 hours,with theinterval of one hour.

ON/OFF buttonPress this button will start the operationsof the units.Press it once again will stopthe operations.

TEMP SETTING buttonEach pressing of the button,the temperature setting isdecreased by 1˚C

MODE buttonThis button is used to select the cooling,heating,or dehumidification mode of operation.sequence of mode switch is cooling-dehumidification-heating.

(For the cooling-only models, the "Heating" mode is for FAN).

LAMP buttonPress this button to make the lamp of controlpanel lights on or off.

MIN buttonThis button is used to set the current time.

HOLD buttonPress this button to lock or unlock the keyboard.

HOUR buttonThis button is used to set the timed timeor the current time.

˚F˚C

ONOFF

MODE

MINHOUR

SLEEP buttonThis button changes to SLEEPoperation,press again to cancelthe sleep operation.

* Above figure shows all indications for the purpose of explanation,but practically only the pertinent.

Remote controller 2

Page 10: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

8

This remote controller is the general one of our company,it can be used for many types of our air-conditioners. We beg your forgiveness that we would not introduce the button or indicator which is notapplicable for the units you purchased.

USER'S MANUALSplit Floor-Standing Air Conditioner

* Above figure shows all indications for the purpose of explanation,but practically only the pertinent.

AUTO

ONOFF

COOL

DRYHEATFAN

SLEEPECONO

POWERCLEANHOLD

MODE TEMP

ON/OFF

TIMER HOUR MIN

SLEEP HOLD LAMP

FAN SPEED CLEAN SWING

Timed time or current time indicator

Heating indicator

Cooling indicator

MODE buttonThis button is used to select the cooling ,dry,heating (faning) mode of operation.

Faning indicator

Drying indicator Sleeping indicatorKey hold indicator

Air flow indicator

TEMP SETTING buttonEach pressing of the button, the temperaturesetting is increased or decreased by 1˚C.

ON/OFF buttonPress this button will start the operations ofthe units.Press it once again will stop theoperations.

HOUR buttonThis button is used to set the timed time orthe current time.

MIN buttonThis button is used to set the current time.

LAMP buttonPress this button to make the lamp of controlpanel lights on or off.

SWING buttonPress this button to select the left/right swingingof air delivery or to stop swinging.

TIMER buttonThis button is used to set the switch-on orswitch-off time. Used together with the"HOUR" button,the time setting can be madewithin the range of 1-12 hours,with the intervalof one hour.

SLEEP buttonThis button changes to sleep operation,pressagain to cancel the sleep operation.

FAN SPEED buttonPress this button to select the high speed,mid-speed or low speed of air delivery.

HOLD buttonPress this button to lock or unlock the keyboard.

Set temperature indicator

Fan speed indicator

Remote controller 3

Page 11: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

USER'S MANUALSplit Floor-Standing Air Conditioner

PRESENT TIME SETTING PROCEDURE

Methods 1(Suitable for remote controller 1and 2)1. When cells are inserted,under the timer operation has not been set,unload the back cover, push the "CLK" button with the tip of aball pen,etc.The time indicator is flickering and can set the present time.2.Press the HOUR button to set you desired time.3.Press the MIN button to set you desired time.4. Press the CLK button again, then reatach the back cover.5.In case of the abnormally use of remote controller,press the RST buttonto reset the remote controller.

Operating Machine In selected modes

1. Point the remote controller at the unit,press the MODE button,select the needed mode :cooling,heating (ventilating for cooling-only model) and dry.2. Press the temperature setting button to increase or decrease the readings until the needed temperature is displayed;* In cooling/heating operations,the temperature difference of 50C between the selected temperature and the ambiend temperatureis most suitable for your health.3. Press fan speed button to choose the air volume you want.4. Press swing button to choose the left/right air direction you want.

9

Methods 2(Suitable for remote controller 3)When cells are inserted,under the timer operation has not been set1.Continually press the HOUR button about 2 seconds,the time indicator is flickering and press the HOUR button to set you desiredtime.2. Continually press the MIN button about 2 seconds,the time indicator is flickering and press the MIN button to set you desiredtime.3.Press the ON/OFF button to confirm the set time or it would automatically exit the time setting state after 15 seconds.If when the remote controller is at abnormal state,you can take out the batteries on the back cover to clear off the display.

CLK

RST

Methods 1

TIMER OPERATION PRODEDURE

1.Duing the operation of the air conditioner,press the TIMER button and the air conditioner will enter the timed switch-off mode.2. Press the HOUR button to set the needed time.Every the button is pressed,indication change is the following sequence:1 * 2 * ........ * 12*1

3.After the setting,the digits shown on the display screen will go down by 1 for every elapsed hour.

Timed switch-off

SLEEP OPERATION PROCEDURE

Use this mode to reduce operation sound when sleeping,etc.Press the SLEEP button,the air flow sound from the indoor unit is decreased.Press the SLEEP button again can release the mode.and the air conditioner will be stopped automatically in 8 hours.

NOTE:* Use the sleep mode when you are going to bed.If this mode is used in the day,the capacity is reduced sincethe ambient temperature is too high.(COOL MODE).* During the operation of cooling,the room temperature will be raised by 10C higher than the setting after themachine begins to operate in the sleeping mode.* During the operation of heating mode,the room temperature will be dropped 20C lower than the setting afterthe machine begins to operate in the sleeping mode.

Page 12: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

REPLACEMENT OF BATTERIES

* When the signal from the remote controller become weak and the indoor unit can not receive itproperly;or the indications on the display screen becomes blurred,please replace with two new batteries.* The positive and negative poles must match the installation positions.* New batteries of the same type have to be used for replacement.* If the remote controller is not to be used for long time,take out the batteries so as to prevent the leakageof the electrolyte from damaging the controller.

NOTE:

1. Do not use an old battery with with a new one.2.The life of cell made in conformity to JIS or IEC is 6 to 12 moths in normal use,If it is used longer or an unspecifiedcell is used,a liquid leaks from the cell,causing the remote controller inoperative.3.Guideline of the life time is printed on the battery.The battery life may be shorter than that of air conditionerdepending on the date of manufacture,However,the battery may be alive ever after the norminal life time expired.

10

1.When the air conditioner is in the standby mode,press the TIMER button and the air conditioner will enter the timed switch-onmode.2.Press the HOUR button to set the needed time,The timer can make the setting in the range from 1-12 hours.3. After the setting.the digits shown on the display screen will go down by 1 for evey elapsed hour.

Timed switch-on

Press the TIMER button again to release the mode.

Releasing procedure

USER'S MANUALSplit Floor-Standing Air Conditioner

Page 13: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

USER'S MANUALSplit Floor-Standing Air Conditioner

*METHODS OF MAINTENANCE*

11

Make sure that the power of the air conditioner is turned off before the maintenance is to be done.

Do not place the air filter screen under the exposure ofsunlight or near an over to dry; do not use warm waterabove 400 C to do the cleaning so as to avoid deformation.

* Power must be turned off beforedoing the cleaning.* Use a piece of soft dry cloth to clearoff the dust on the units.* Do not use volatile oil, gasoline,diluting agents or abrasive power, etc.in doing the cleaning.* Use household neutral detergent toclean the fingerprints or oil stains.* Do not use water to flush the units.

N.B

Cleaning

* Check to see if the power cable and grounding wire arein proper state.

* Check and confirm that there is any bending, orraised ends or blockage of the drainage tubes.

* Make sure that the air filter screen is properly in placebefore operating the machine.

* Disconnect the power sourceof the air conditioner.* Before pulling out the powerplug, make sure that theoperation of the machine is fullystopped.

* Please use a plasticsheet to cover the unitto prevent dust or filthfrom entering the outdoorunit.

Prior To Operational Seasons

Air outletis blocked.

Air inlet isblocked. * Make proper maintenance to the air filter screen and

other parts.

Gently pat the screen or use a vacuumcleaner to do the cleaning. If too muchfilth is accumulated on the screen, asmall amount of neutral detergentsolution can be used for the cleaning.After the cleaning, the screen must bedried in air and be put back into place.

Cleaning of the filter screen* Make sure that the operation of theair conditioner is fully stopped.* Remove the fixing screws of the air-return grids.* Pull in the direction of arrow (1) toopen the grids.* Pull in the direction of arrow (2) totake out the air filter screen. (The air filter screen is loaded insidethe air-return grids).

*

*

Handle

Removal of the filter screen

After The Operational Seasons

If the machine is operated with the air filter screen removed, dust and foreign objectswill result in faulty performances of the air conditioner.

* Check to see if the air outlets of the indoor and outdoorunits are blocked;* The protective cover of the outdoor unit must beremoved.

Page 14: USER'S MANUAL - chigo.ro · PDF fileSplit Floor-Standing Air Conditioner Please read the user's manual carefully before using the product GL17Eng. Foreword ... mode,the AC will operate

*PHENOMENA DIAGNOSIS AND TREATMENT*

Please read the following contents before contacting the maintenance people:

If the above-stated problem is not solved even after the related corrective measure is taken, please disconnect the power sourceand contact our Co. dealer of the authorized maintenance shop.

The following phenomena air not faulty operational performances:

Sometimes the air sent out from the airconditioner may smell some odd odors.This is due to the cigarette smoke, thecosmetic smell, the odors of walls orfurniture pieces in the room that arestained on the air conditioner.

During the operation or when the machineis stopped, some "ZZZ..." sound may beheard. This is because the refrigerantinside the air conditioner is still flowing.

When the cooling or heating operation isstarted or stopped, some "patting" soundmay be heard. This is because some partsof the surface boards are expanded dueto changes of temperature, which resultsin the friction of these parts. This is not aperformance fault.

Unpleasantsmell

The air inside theroom smells cigarettesmoke or other oddodors.

TROUBLE PHENOMENA CAUSES TREATMENT

Air conditionerdoes not work.

Press the ON/OFFbutton but the airconditioner does notwork.

Power failurePress the ON/OFF button again afterthe power is resumed

There is air deliveryat the outlet, but itis not cooling orheating

Control panelindications normal

Room temperature not properlyadjusted

Blocking objects at the inlet oroutlet of the indoor or outdoor units

Reduce or increase the roomtemperature setting.

Door or windows open

Remove the objects.

Power source not connected Connect to the power source.

Fuse blown Replace fuse

Breaker in off position Connect the breaker.

Dust blocking the air filter screen Clean the air filter screen.

Close the door or windows.

"Pattingsound"

The sound of refrigerant flowing

"ZZZ..."

USER'S MANUALSplit Floor-Standing Air Conditioner